Military Engineer Services Tender
Calculate bid estimation of Manipur MES Tender
Costs
EMD
₹ 79,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_704100_1Tender No
8662/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Material and labour for replacement of unserviceable hermitically sealed compressor of Refrigerator 165 Ltr to 410 ltr. Capacity with fresh new uncut sealed compressor including suitable relay and over load with new sealed unit as per the company scheme supplied by the manufacturer complete including flushing out system, checking and rectification of leakage, gas charging, complete and testing after completion of work at MES Store yard for satisfactory function. Note:- (i) The rate quoted by the contractor shall be inclusive of all charges like transportation, fitting etc complete with necessary guarantee period as per company terms and conditions. (ii) The new unit will be purchased from authorized dealer
18
-
-
... More
Material and labour for replacement of relay suitable for existing make and model of refrigerator.
8
-
-
... More
Material and labour for replacement of thermostat automatic `R' frost with knob suitable for 165/190/310 liters cap refrigerator
20
-
-
... More
Material and labour for replacement of door gasket of best quality complete suitable for existing make and model of refrigerator as per manufacturer's instruction and as directed by EIC.
6
-
-
... More
Material and labour for bulb for pin /screw type , 230 Volts suitable for existing make and model of refrigerator.
35
-
-
... More
Material and labour for replacement of freezer door incl. necessary door springs, screws etc. for 165 to 410 Ltrs. Cap. Refrigerator complete all as specified and directed by EIC.
15
-
-
... More
Material and labour for replacement of door lock for any capacity of refrigerator as per sample approved by EIC
5
-
-
... More
Material and labour for replacement of PVC chill tray and suitable for 165 to 410 Ltrs Cap. refrigerator complete all as specified and directed.
20
-
-
... More
Material and labour for replacement of refrigerator door handle of 165/ 286/310 Ltrs Cap. of any make.and model
5
-
-
... More
Material and labour for replacement of freezer assy complete with screw, jointing of tubes etc. and testing of cap. 165 to 410 Ltrs. refrigerator (any make)
8
-
-
... More
Material and labour for replacement of condensor unit of refrigerator cap. 165 to 410 Ltrs of any make incl. jointing of tubes and testing etc. complete all as specified and directed.
8
-
-
... More
M&L for replacement of capacitor suitable for any type and any capaity of refrigearator complete all as specified and as directed.
20
-
-
... More
Material and Labour for flushing of system , testing and repairs of leakages in system charging of Gas(between inner cooling cabin and outer fabrication) , Oil complete incl. testing and commissioning of refrigerator of any capacity any make complete all as directed by EIC.
Note: Spares to be used in gas charging shall be deemed to be considered in quoted rates.
35
-
-
... More
Material and labour for taking out deep frezzer of any size and any make to the workshop for general body work repairs including patch work and hinges and locking work complete after removing rusted part and repairing complete fabrication work what ever is required complete making it in good presentable condition after painting work complete all as specified and directed by EIC. Note: Rates for transportation to and fro from site to workshop shall be deemed to be considered in quoted rates.
20
-
-
... More
Material and Labour for flushing of system , testing and repairs of leakages in system charging of Gas(between inner cooling cabin and outer fabrication) , Oil complete incl. testing and commissioning of deep frezzer of any capacity any make complete all as directed by EIC.
Note: Spares to be used gas charging shall be deemed to be considered in quoted rates.
15
-
-
... More
Material and Labour for replacement of unserviceable hermitically sealed compressor suitable for deep freezer of any capacity any make with new uncut sealed compressor supplied by manufacture complete all as specified and directed.
12
-
-
... More
Supply and fix fan motor with fan blade suitable for any type of deep freezer complete all as specified and as directed.
8
-
-
... More
Material and labour for carry out maintenance/ servicing of modular cold room, 1.0 Tone (Blue Star) capacity installed at LMS. Maintenance/ servicing includs followings:-
(i) Cleaning the both unit indoor & outdoor including evaporator coil, condencer coil, air blower with Chemical & Water (Wet Service).
(ii) Checking the refrigerant piping for any kind of leakage and rectifying the same.
(iii) Cleaning the Air Filter .
(iv) Checking the drain line of the machine .
(v) Greasing of motor & blower bearings and rewinding in case of brunout of the motor windings .
(vi) Checking the Overload Relays and change if required.
(vii) Checking the operation of the thermostat
(viii)Checking the abnormal sound & vibration of the machine and rectify the same
(ix) Checking the Gas Pressure of the machine (if low) Refilling the same Gas as much as required.
(x) Replacement of Driers, Compressor Lubricating oil as and when required.
(xi) Replacement of Contract Relay if Required.
24
-
-
... More
Supply and fixing starting capacitor clip type of cap. 80-100 MFD,440 volts 50 Hz
2
-
-
... More
Supply and fixing running capacitor clip type of cap. 45 MFD, 240 volts 50 cycles
2
-
-
... More
Supply and fixing starting capacitor clip type of cap. 100-120 MFD,440 volts 50 Hz
2
-
-
... More
Supply and fixing over load protector with relay suitable of cold storage complete all as specified and directed.
2
-
-
... More
Material and labour for replacement of thermostat switch suitable of cold storage complete all as specified and directed.
1
-
-
... More
Material and Labour for replacement of unserviceable hermitically sealed compressor suitable for cold atorage of any make/ capacity with new uncut sealed compressor supplied by manufacture complete
2
-
-
... More
Material and labour for replacement of outdoor condenser fan motor of Speed 1200 RPM of cold room unit of existing capacity including worn out bushes ,Shaft and capacitor etc and testing complete. Make as per existing make and model.
2
-
-
... More
Material and labour for replacement of indoor evaporator fan motor of Speed 1200 RPM of cold room unit of existing capacity including worn out bushes ,Shaft and capacitor etc and testing complete. Make as per existing make and model.
4
-
-
... More
M&L for repalcement of temperature controllar (Digital Temperature Meter) suitable for controll two compressor with separate set points and differentials for each comperssor complete all as specified and directed.
1
-
-
... More
M&L for repalcement of temperature controllar display suitable for existing make and model of modular cold room 1.0 tone capacity.
1
-
-
... More
S&F in repair of contactor suitable for modular cold room 1.0 tone capacity as per esisting make and model all as speciofied and directed.
2
-
-
... More
M&L for attending complaint of split type/window type AC of any capacity any type complete all as specified and directed.
Note : (i) loose connection/ fuse change/burnt lugs repaired included in item rate.
(ii) Spare parts should be paid under relevent items here in after.
25
-
-
... More
Taking down carefully split type AC of capacity 1.5 / 2.0 ton & shifting on new location complete with pre fabricated brackets/ frame work including drilling, making hole and filling the hole by white cement/ putty and hanging with the help of anchor hold fastener/ nut, bolts & washers as required and making the good disturbed surface without any damage outdoor & indoor unit complete all as specified and directed.
12
-
-
... More
Supply & fix Angle Bracket of any size and type suitable for supporting to out door unit of split type AC including hold fastener/ nut, bolts & washers complete all as specified and directed by Engineer-in-Charge.
10
-
-
... More
Material and labour for flushing out system, checking and rectification of leakages if any and make it serviceable incl. gas charging with refrigerant R-22/R404/R132/R32 , oil charging complete in compressor window type AC/ Split type AC cap.1.5/2 Ton and testing all as directed & with entire satisfaction of Engineer-in-Charge.
35
-
-
... More
Material and labour for servicing /overhauling/ of split/ window type AC 1.5/2 Ton capacity including dismantling, Cleaning and descaling of condensing unit, cooling coil and air blower with caustic soda mixed water and taking out all dirt /sludge, greasing the fan motor, painting of outer cover and components with synthetic enameled paint of colour as directed and installation at same place complete all as specified and directed.
35
-
-
... More
Taking out old unserviceable condenser coil of 1.5/2.0 Ton Split type AC any make with fins cutting inlet & outlet connecting copper pipe and providing new condensor coil with fins and connecting inlet & outlet copper pipe by bracing and replacement of nut bolts etc complete all as specified and directed
10
-
-
... More
Taking out old unserviceable cooling coil of 1.5/2.0 Ton Split type AC any make with fins cutting inlet & outlet connecting copper pipe and providing new cooling coil with fins and connecting inlet & outlet copper pipe by bracing and replacement of nut bolts etc complete all as specified and directed
5
-
-
... More
Material and labour for replacement of unserviceable cut sealed compressor of Split/ window ACs 1.5 TR capacity with new uncut sealed hermetically compressor unit supplied by the manufacturer complete unit including wiring as required to unit with flushing out system checking and rectification of leakage, gas charging complete and testing after completion of work at MES store yard for satisfactory functioning complete all as specified and directed. Note:- (i) The rate quoted by the contractor shall be inclusive of all charges like transportation, fitting etc complete with necessary guarantee period as per company terms & conditions. (ii) The new compressor unit will be purchased from authorized dealers only as per existing make and model.
15
-
-
... More
Material and labour for replacement of unserviceable cut sealed compressor of Split/ window ACs 2.0 TR capacity with new uncut sealed hermetically compressor unit supplied by the manufacturer complete unit including wiring as required to unit with flushing out system checking and rectification of leakage, gas charging complete and testing after completion of work at MES store yard for satisfactory functioning complete all as specified and directed.
Note:- (i) The rate quoted by the contractor shall be inclusive of all charges like transportation, fitting etc complete with necessary guarantee period as per company terms & conditions. (ii) The new compressor unit will be purchased from authorized dealers only as per existing make and model.
4
-
-
... More
Material and labour for replacement of blower motor of Speed 1200 RPM of window/Split Air conditioner of cap. 1/5HP of any make including worn out bushes ,Shaft and capacitor etc and testing complete. Make as per sample/site requirement
10
-
-
... More
Material and labour for replacement of outdoor condenser fan motor of Speed 1200 RPM of window/Split Air conditioner of existing capacity including worn out bushes ,Shaft and capacitor etc and testing complete. Make as per sample/site requirement
15
-
-
... More
Supply,fixing and testing in replacement of fan blade for condensing unit suitable for Split type Air conditioner of 1.5 / 2.0 Ton capacity including removing old fan blade.
15
-
-
... More
Material and labour for replacement of swing motor for indoor unit of split type of cap 1.5 /2 TR as per existing make/model
15
-
-
... More
Supply and fixing running capacitor clip type of cap. 36 MFD, 240 volts 50 cycles for Split type air conditioner 1.5 Ton Cap.
15
-
-
... More
Supply and fixing starting capacitor clip type of cap. 80-100 MFD,440 volts 50 Hz for Split type air conditioner.
15
-
-
... More
Supply and fixing running capacitor clip type of cap. 45 MFD, 240 volts 50 cycles for Split type air conditioner 2 Ton Cap.
10
-
-
... More
Supply and fixing starting capacitor clip type of cap. 100-120 MFD,440 volts 50 Hz for Split type air conditioner.
10
-
-
... More
Supply & Fix blower fan motor capacitor 4 MFD for AC.
12
-
-
... More
Supply & Fix blower fan motor capacitor 6 MFD Water cooler.
16
-
-
... More
Supply and fixing over load protector with relay for AC 1.5/2 ton capacity.
10
-
-
... More
Material and labour for replacement of thermostat switch for AC cap.1.5/2.00 ton.
10
-
-
... More
Supply and fixing Connector unit
8
-
-
... More
Supply and fixing Foam type insulating flexible pipe fitted on suction /discharge copper tubes.
70
-
-
... More
Supply and fixing PCB Card including connecting accessories for split type AC of capacity 1.5 TR
15
-
-
... More
Supply and fixing PCB Card including connecting accessories for split type AC of capacity 2 TR
8
-
-
... More
Supply and fixing PCB Card including connecting accessories for split type AC of capacity 1.5 TR/2 TR (inverter)(Indoor)
8
-
-
... More
Supply and fixing PCB Card including connecting accessories for split type AC of capacity 1.5 TR/2 TR (Inverter)(Out door)
8
-
-
... More
Supply and fixing PCB Card including connecting accessories for split type AC of capacity 1.5 TR (hot/cold)
5
-
-
... More
Supply and fixing PCB Card including connecting accessories for split type AC of capacity 2 TR (hot/cold)
5
-
-
... More
Supply and fixing in replacement of remote handset suitable for 1.5/2.0 Ton capacity split type AC/ window AC etc. complete all as specified and directed
8
-
-
... More
Supply and fixing Valve 1/2 " ,1/4 " and 5/8 " for split/window type of capacity 1.5/2.0 TR
12
-
-
... More
Supply and fixing Display unit for split/ window AC 1.5/2 Ton capacity
5
-
-
... More
Material and labour for replacement of copper pipe of size 1/4 " from outdoor unit to indoor unit including soldering and brazing
20
-
-
... More
Material and labour for replacement of copper pipe of size 1/2 " from outdoor unit to indoor unit including soldering and brazing
20
-
-
... More
Material and labour for replacement of copper pipe of size 5/8 " from outdoor unit to indoor unit including soldering and brazing
25
-
-
... More
Supply and fixing single pole and neutral enclosure with 2 pin earth industrial plug and socket complete with one MCB SP 25 Amps (Make- Legrand/C&S/Havells) as in replacement.
8
-
-
... More
Material and Labour for Replacement of copper filter and capillary tube.
10
-
-
... More
S&F in repair cable PVC insulated 3 core 4 Sq mm with copper conductor cable suitable for indoor unit to outdoor unit after taking out old unserviceable complete all as directed by Engineer-in-Charge.
65
-
-
... More
Material and Labour for replacement of PVC drain pipe, 15/20 mm bore with steel clamps and necessary brass screws etc. all as directed
50
-
-
... More
Supply and fix in repair voltage stablizer for automatic operation single phase naturally air cooled indoor type having low and high voltage cut-off protection, inbuilt thermal protection & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy +/- 2.5% and suitable forsplit/ window type ACs of 1.5/2.0 TR capacity, Refrigerators of capacity165 to 410 ltrs and Deep freezers 195 to 410 ltrs capacity complete all as specified and directed.
15
-
-
... More
Material and Labour for Replacement of relay with over load protectors for 40 Ltr/hr cooling capacity suitable as per site requirement complete all as specified and directed.
2
-
-
... More
Material and Labour for Replacement of condenser fan of motor HP- 1/32 ,RPM-1300 suitable for water cooler having cooling cap 40 Ltr/hr with clips and motor fixing stand with fan blade.
1
-
-
... More
Material and Labour for Replacement of thermostat switch with knob for water cooler. having cooling capacity 40 Ltrs /hr complete all as specified and directed.
2
-
-
... More
Material and Labour for replacement of rubber beading fixed with top cover of water cooler of 40 liters/hour capacity.
2
-
-
... More
Supply and fix push cock, 15mm bore made of brass self closing vertical type made of brass nickle chromium plated- Make Mayor/ C-Sons/G-Sons
2
-
-
... More
Material and Labour for replacement of connectors made of brass nickle chromium plated suitable for water cooler having cooling capacity 40 litres per hour
2
-
-
... More
Material and Labour for replacement of unserviceable hermitically sealed compressor suitable for water cooler cooling capacity 40 liters/hour with new uncut sealed compressor supplied by manufacture complete.
Note Old sealed compressor of any type will be property of contractor.
2
-
-
... More
Material and Labour for Replacement of starting capacitor 40/60 Mfd oil filled 240 volt AC Supply.
2
-
-
... More
Material and Labour for Replacement of running capacitor of 10/25 Mfd oil filled Make: Asian/ Atlas/Epcos/SPAN/Sharda
2
-
-
... More
Material and Labour for flushing of system , testing and repairs of leakages in system charging of Gas same as existing, Oil complete incl. testing and commissioning of water cooler having cooling Capacity. 40 Ltrs.per hour. of any make.
2
-
-
... More
Material and Labour for condenser unit complete suitable for 40 Ltr/Hr cap. water cooler including gas charging flushing out the system brazing, welding and jointing the suction reed valve and discharge reed valve complete all as per direction of Engineer-in-Charge
1
-
-
... More
Supply & fix fan motor suitable for water cooler of any capacity including removing old fan motor and testing complete.
2
-
-
... More
Supply, fixing and testing fan blade suitable for water cooler of any capacity including removing old fan blade.
2
-
-
... More
Supply & fix of Float valve suitabie for Water cooler of any capacity.
4
-
-
... More
Taking down and dismantling of aquaguard water purifier of 50 LPH capacity from its existing location for servicing, cleaning of components such as housings, pre-filter, sendiment filter, carbon filters, low pressure valve, solenoid valve, membranes etc or replacement of defective filters, vlaves and membrance etc and reassembling the water purifier with all safety devices and reinstallation at the same location as directed by engr-in-charge.
Notes:- (i) Spare parts, safety devices with its required accessories shall be measured and paid seperately .
20
-
-
... More
Supply only following spare parts of water purifier 50 LPH capacity ISI marked. (86.01) Supply only in replacement of water purifier membrane per existing make and model.
40
-
-
... More
(86.02)Supply only in replacement of sendiment filter as per existing make and model..
20
-
-
... More
(86.03) Supply only in replacement of carbon filter as per existing make and model..
10
-
-
... More
(86.04) Supply only in replacement of housing of filter as per existing make and model..
10
-
-
... More
(86.05) Supply only in replacement of SMPS adapter as per existing make and model..
2
-
-
... More
(86.06) Supply only in replacement of booster pump as per existing make and model.
4
-
-
... More
(86.07) Supply only in replacement of low pressure switch as per existing make and model..
2
-
-
... More
(86.07) Supply only in replacement of solenoid valve as per existing make and model..
2
-
-
... More
Taking down and dismantling of Air curtain from its existing location for servicing/ overhauling including cleaning internal external both side, cleaning and greasing of fan motor, replacement of condencer, PCB Card and defective components if required and reassembling and reinstallation at the same location as directed by engr-in-charge.
Notes:- (i) Spare parts, safety devices with its required accessories shall be measured and paid seperately .
6
-
-
... More
(96.01) Supply only in replacement of blower motor of Air Curtain of existing capacity of any make including worn out bushes ,Shaft and capacitor etc and testing complete. Make as per sample/site requirement.
2
-
-
... More
(96.02) Supply only in replacement of blower of Air Curtain suitable for existing make and model and testing complete all as specified and directed.
4
-
-
... More
(96.03) Supply only in replacement of PCB Card of air curtain suitable for existing make and model complete all as specified and directed.
2
-
-
... More
(96.04) Supply only in replacement of capacitor for blower fan motor 4 to 8 MFD suitable for existing make and model of Air Curtain complete all as specified and directed.
8
-
-
... More
Taking down copper/ aluminium point wiring ie. light, fan, socket or power/points complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. and making good disturbed surfaces of ceiling, walls, floors, etc.
40
-
-
... More
M&L for point wiring with two single core 2.5 sqmm (nominal area) FRLSH PVC insulated unsheathed cable, 1100 volts grade multistranded copper conductor cable in and incl PVC casing and capping of suitable size fixed on surface all as directed with using modular PVC boxes including modular frame and white cover plate for mounting modular switches, sockets and fan regulators etc incl all accessories and using one single core 2.5 sqmm (nominal area) FRLSH PVC insulated unsheathed multistranded copper conductor cable, 1100 volts grade as in earth wire connected to common earth dully complete all as specified and directed.
Note :
(i) The quoted rates shall be deemed to be inclusive for fixing the PVC casing caping to surface.
(ii) Fititngs like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid appropriate item of schedule ‘A’ (a) one 3 pin, 15 Amps socket outlet on independent board.
40
-
-
... More
S&F modular switch, 16 Amps, single pole, one way complete all as specified and directed.
40
-
-
... More
S&F modular Socket multipurpose 3 pin 16 Amps and 3 pin 6 Amps combined 2 module complete all as specified and directed.
40
-
-
... More
S&F in repair modular PVC Box including White cover plate with frame, 3 module complete all as specified and directed.
40
-
-
... More
S&F in repair for submain wiring with single core 4.0 sqmm PVC FRLS insulated unsheathed cable multistranded copper conductor drawn through and inclduing PVC casing capping of suitable size with all fittings and fixing accessories on roof , walls, ceiling etc including 4.00 Sqmm PVC insulated unsheathed one core multistranded copper condutor earth wire complete all as specified and directed. (Note : Two runs of single core cable and one run of earth wire will be measured as one length)
70
-
-
... More
S&F in repair 15 Amp plug top complete all as specified and directed.
20
-
-
... More
Taking down and dismantling of storage type water geysers of 25/50 ltrs capacity any type any make, any model, from its existing location, transportation to work shop for repairs and transportation back and reinstallation of geyser as per technical instructions and as directed by engr-in-charge and including the following:-
(a) Dismantling complete geyser and carrying out complete overhauling i.e; disconnecting electric supply and opening the heating plate, inner assembly, descaling complete assembly including heating element or otherwise. Replacement of defective heating element inlet and outlet tubes and refixing the assembly with gasket of good quality and tightening the nuts properly, reassembling geyser with all safety devices as specified in technical instructions and as directed by Engineer -in- Charge complete.
Notes:- (i) Spare parts, safety devices with its required accessories shall be measured and paid seperately .
40
-
-
... More
Supply only following spare parts of geysers 50/25 Ltrs capacity ISI marked. (108.01) Heating element 1.5/2 KW suitable for operation on 230V AC 50Hz
40
-
-
... More
(108.02) Thermostat 40 to 90 degree centigrade varying capactiy for 25/50 Ltrs capacity Geyser.
35
-
-
... More
(108.03) Flexible conneciton pipe for hot water with brass check nuts complete as per site requirement all as specified and directed by Engineer-In-Charge.
40
-
-
... More
(108.04) Flexible conneciton pipe for cold water with brass check nuts complete as per site requirement all as specified and directed by Engineer-In-Charge.
40
-
-
... More
(108.05) Indicator lamp assembly for geyser as per existing make and model complete all as specified and directed by Engr-In-Charge.
15
-
-
... More
(108.06) Syphon assembly suitable for 25/50 ltr geyser complete including nuts and washer complete all as specified and directed.
20
-
-
... More
(108.07) Geyser brass tank for 25/50 ltr geyser complete including nuts, washer, glass wool etc complete all as specified and directed.
4
-
-
... More
M&L in repair for Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanized earth wire 4mm dia by means of galvanized iron or steel bolts nuts check nuts and washers and other end connected with earthing testing point including providing suitable testing points as directed including funnel, watering pipe of 20mm bore, light grade galvanized iron pipe, wire mesh charcoal of coal dust and common salt in alternative layer all around the earth electrode compacted thickness 15cm with concrete pit in PCC 1:3:6 type C1 50mm thick pre cast RCC 1:2:4 type B1 cover slab set in CM (1:4) re-enforcement with 8mm dia deformed bars @ 15cm C/C and suitable handle of 10mm dia MS round bars, including earth work in hard/dense soil as required complete all as shown in electrical plate No 3 of MES Schedule Part I and testing on completion complete all as specified and as directed. (Note: Earth strip beyond 7.5 m length will be measured & paid separately)
2
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%