Manipur University Tender
View complete overview of Manipur Manipur University Tender
Manipur University Tender
Civil And Construction
Building Construction
Eprocure
Opening Date31 Jul 2024
Closing Date9 Aug 2024
Tender Amount₹ 6,57,240
Costs
EMD
₹ 13,145Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Repairing And Providing I.e.i For The 1st Floor Of Erstwhile Boys Hostel - 1 For Drawing Hall Of Mit At Takyelpat Campus.
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MU_819259_1Bid Award Id
ViewTender No
6/74/23-MIT/DH-REP/510Tender Authority
Manipur University ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
15.1.1 Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
13.62
-
-
Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge
2
-
-
Renewing glass panes, with putty and nails wherever necessary:
-
-
-
14.5.1 Float glass panes of thickness 4 mm
9.17
-
-
Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead.
155.3
-
-
Half brick masonry with Ist class common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level upto floor V level in
-
-
-
6.9.1 Cement mortar 1 : 3 (1 cement : 3 coarse sand)
18.81
-
-
15 mm cement plaster on rough side of single or half brick wall of mix:-
-
-
-
13.2.1 1:4 (1 cement : 4 fine sand)
135.79
-
-
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete.
-
-
-
11.32.1 Size of Tile 600 x 600 mm
163.54
-
-
Tile work in skirting, risers of steps and dado (upto 2 m height) over 12 mm thick bed of cement mortar 1:3 (1 cement :3 coarse sand) and jointed with grey cement slurry @ 3.3 kg/sqm including pointing in white cement mixed with pigment of matching shade complete.
-
-
-
11.15.1 Marble tiles (polished) Raj Nagar.
-
-
-
11.15.1.1 8 mm thick
9.58
-
-
Providing wood work in frames of doors, windows, clerestory windows and other frames,wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length (hold fast lugs or dash fastener shall be paid for separately :
-
-
-
9.1.3 Local best quality Tolhao wood.
0.04
-
-
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows including ISI marked M.S butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge.
-
-
-
9.5.2 Local best quality Tolhao wood.
-
-
-
9.5.2.1 35 mm thick shutters
6.58
-
-
Providing and fixing IS : 1341 marked M.S. heavy weight butt hinges with necessary screws etc. complete
-
-
-
9.30.1 125x90x4.00 mm
18
-
-
Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :
-
-
-
9.63.1 300x16 mm
6
-
-
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete :
-
-
-
9.64.1 300x10 mm
12
-
-
Providing and fixing insulating board ceiling of approved quality with necessary nails etc. complete (framework to be paid separately):
-
-
-
12.22.1 Natural colour insulating board
-
-
-
12.22.1.1 12 mm thick
56
-
-
Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
134.34
-
-
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade
-
-
-
13.29.1 New work (two or more coats) over and including priming coat with cement primer:-
134.34
-
-
Applying priming coat:-
-
-
-
13.37.1 With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)
71.72
-
-
Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture
15.72
-
-
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :
-
-
-
14.42.2 One or more coats on old work
163.54
-
-
Sub- Head No. II ( Electrical Work )
-
-
-
Wiring for light point / Fan point / Exhaust Fan point / Call bell point with 1.5 mm2 FR PVC insutated copper conductor single core cable in PVC casing & capping with modular type switch, modular plate suitable size, G.I-box and earthing the point with 1.5 mm2 FR PVC insulated copper conductor single core cable etc. as reqd.
-
-
-
i) Lt Pt. Group - B
32
-
-
i) Fan Pt. Group - B
13
-
-
Wiring for light point / Power Plug point with 2 x 4 mm2 FR PVC insutated copper conductor single core cable in PVC casing & capping along with 1 no. 4 mm2 FR PVC insulated copper conductor single core cable for loop earthing etc. as reqd.
-
-
-
i) Lt. Plug Pt.
5
-
-
ii) Power Plug Pt.
4
-
-
S/F suitable size G.I box with modular plate and cover in front on surface or in recess i/c P/F 3 pin 5/6 amp modular socket 5/6 amp modular switch, connection painting etc. as reqd. ( for light plug to use in non - residential building )
5
-
-
S/F suitable size G.I box with modular plate and cover in front on surface or in recess i/c P/F 6 pin 15/16 amp modular socket outlet and 15/16 amp modular switch, connection painting etc. as reqd. ( for light plug to use in non - residential building )
4
-
-
Wiring for circuit / Sub - main wiring along with wire with the following size of FR PVC insulated copper conductor single core cable in PVC cassing & capping etc. as reqd.
-
-
-
i) 2 x 2.5 mm2 + 1 x 2.5 mm2 earth wire
70
-
-
ii) 2 x 4 mm2 + 1 x 4 mm2 earth wire
80
-
-
iii) 2 x 6 mm2 + 1 x 6 mm2 earth wire
60
-
-
S/F 3 pin 5 amp ceiling rose on the existing junction box / wooden block i/c connection etc. as reqd.
71
-
-
S/F Brass Batten / Angle holder i/c connection etc. as reqd.
8
-
-
S/F 20 W CFL Lamp
8
-
-
S/F Pre - coated electronic box type luminaries with decorative end caps FTL 1 x 36 / 40 W lamp complete with all accessories i/c connection etc. as reqd.
24
-
-
S/F 48 " sweep (1200 mm) A.C ceiling fan complete with down rod, canopy, 3 (three ) blades but without regulator etc. as reqd. ( Make Bajaj / Usha or similar )
13
-
-
Supplying & Fixing stepped type electronic Fan Regulator on the existing modular plate switch box i/c connection but excluding modular plate etc. as reqd.
13
-
-
S/F 2 + 8 way, single pole and neutral, sheet steel MCB distribution board, 240 V on surface / recessed complete with tinned copper bus bar neutral bus bar, earth bar, din bar, hinged front acrylic cover for the MCCB knobs detachable gland plate , interconnection, phosphatized and powder painted including earthing etc. as reqd. ( but without MCB / RCCB / Isolator)
2
-
-
Supplying and fixing 5 amp to 32 amp rating 230 V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection, testing and commissioning etc. as reqd.
-
-
-
i) Single Pole
12
-
-
S/F ( following rating) four pole 240 V isolator in the existing MCB DB complete with connection, testing and commissioning as reqd.
-
-
-
1. 63 amp
2
-
-