Manipur University Tender
View complete overview of Manipur Manipur University Tender
Manipur University Tender
Civil And Construction
Building Construction
Eprocure
Opening Date18 Jun 2024
Closing Date26 Jun 2024
Tender Amount₹ 10,51,112
Costs
EMD
₹ 21,025Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MU_812272_1Bid Award Id
ViewTender No
MU/2(185)/2023-UE/337Tender Authority
Manipur University ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metre lead.
6.48
-
-
For thickness of tiles above 25 mm and upto 40 mm
-
-
-
12 mm cement plaster of mix:
131.55
-
-
1:4 (1 cement : 4 fine sand)
-
-
-
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.
16.2
-
-
Double charge vitrified tile polished finish of sized)
-
-
-
Size of Tile 600 x 600 mm
-
-
-
Providing wood work in frames of doors, windows, clerestory windows and other frames,wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length (hold fast lugs or dash fastener shall be paid for separately :
6.13
-
-
Local best quality Uningthou wood
-
-
-
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows including ISI marked M.S butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge.
3.9
-
-
Local best quality Tolhao wood.
-
-
-
35 mm thick shutters
-
-
-
Providing and fixing aluminium work for doors, windows, ventilators and partitionswith extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required EPDM rubber/ Neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleatangle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steelscrews, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and panelling to be paid for separately):
97.25
-
-
For fixed portion.
-
-
-
Powder coated aluminium (minimum thickness of powder coating 50 micron)
-
-
-
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
15.04
-
-
With float glass panes of 8 mm thickness
-
-
-
Providing and fixing Pre-laminated with decorative lamination on both side exterior Grade-I MDF Board 18 mm thick confirming to IS:14587
116.82
-
-
Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
106.92
-
-
Finishing walls with Deluxe Multi surface paint system for interiors and exteriors using Primer as permanufacturers specifications :
213.84
-
-
Two or more coats applied @ 1.25 ltr/10 sqm. over and including one coat of Special primer applied @0.75 ltr/10 sqm.
-
-
-
Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture
148.38
-
-
Electrical Work
-
-
-
Wiring for light point / Fan point / Exhaust Fan point / Call bell point with 1.5 mm2 FR PVC insutated copper conductor single core cable in PVC casing & capping with modular type switch, modular plate suitable size, G.I-box and earthing the point with 1.5 mm2 FR PVC insulated copper conductor single core cable etc. as reqd.
-
-
-
2. Group B
8
-
-
Wiring for Power Plug point with 2 x 4 mm2 FR PVC insutated copper conductor single core cable in PVC casing & capping along with 1 no. 4 mm2 FR PVC insulated copper conductor single core cable for loop earthing etc. as reqd.
3
-
-
Supply and drawing the following size of PVC insulated Al. conductor single core cable in existing PVC casing & capping etc. as reqd
-
-
-
2. 2 x 1.5 mm2
100
-
-
7. 2 x 2.5 mm2
270
-
-
12. 2 x 4 mm 2
90
-
-
17. 2 x 6 mm2
80
-
-
S/F 152.4 mm x 203.2 mm ( 6" x 8") PVC board
2
-
-
S/F 203.2 mm x 254 mm ( 8" x 10") PVC board
30
-
-
S/F square box 12 mm to 32 mm
8
-
-
S/F brass batten/ angle holder i/c connectio etc. as reqd.
8
-
-
Supply & Fixing( following piano type switch / socket) on the existing switch box / cover i/c connection etc. as reqd.
-
-
-
1. 5 / 6 amps switch
100
-
-
4. 3 pin 5/6 amps socket outlet
100
-
-
S/F PVC box of size 203mm x 178mm ( Nominal size) ( 6" x 8") PVC board on surface incuding P/F 6 pin 15/16 amp socket outlet and 15/16 amp piano type switch, connection etc. as reqd.
3
-
-
S/F 56 " sweep (1400 mm) A.C ceiling fan complete with down rod, canopy, 3 (three ) blades but without regulator etc. as reqd. ( Make Bajaj / Usha or similar )
4
-
-
Supplying & Fixing stepped type electronic Fan Regulator on the existing modular plate switch box i/c connection but excluding modular plate etc. as reqd.
4
-
-
S/F brass batten/ angle holder i/c connectio etc. as reqd.
8
-
-
S/F 3 pin 5 amp ceiling rose on the existing junction box / wooden block i/c connection etc. as reqd.
4
-
-
Providing and Fixings ( following capacity TP & N ) dis-connector fuse switch unit inside the existing cubical panel board with ISI marks HRC fuses including drilling holes in the cubical panel board, making connection as reqd.
-
-
-
2. 63 amp TP & N
1
-
-
S/F Bus bar chamber with 4 strips bus bar of length 300 mm suitable for 63 amp capacity complete with all accessories i/c connection, earthing the body etc. as reqd.
1
-
-
S/F ( following way), single / double pole and neutral, sheet steel MCB distribution board, 240 V on surface / recessed complete with tinned copper bus bar neutral bus bar, earth bar, din bar, detachable gland plate, interconnection, phosphatized and powder painted including earthing etc. as reqd. ( but without MCB / RCCB / Isolator)
-
-
-
3. 8 way single door
1
-
-
Supplying and fixing 5 amp to 32 amp rating 230 V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection, testing and commissioning etc. as reqd.
-
-
-
1. Single Pole
6
-
-
S/F ( following rating) double pole 240 V isolator in the existing MCB DB complete with connection, testing and commissioning as reqd.
-
-
-
2. 63 amp
1
-
-
S/F 23 W CFL. Lamp
8
-
-
Earthing with copper plate 600 mm x 600 mm x 6 mm thick i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) as reqd.
1
-
-
Extra for using salt and charcoal for G.I or copper plate earth electrode as reqd.
1
-
-
P/F 25mm x 5mm copper strip in 40 mm dia G.I pipe from earth electrode as reqd.
15
-
-
S/L 8 SWG copper wire on surface or in recessed for loop earthing along with existing surface / recessed conduit wiring/ sub main wiring / cable as reqd.
20
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements