Manipur State Rural Roads Development Agency Tender

View complete overview of Manipur MSRRDA Tender

Manipur State Rural Roads Development Agency - MSRRDA Tender

Works
Civil And Construction
Eprocure
Opening Date14 Sep 2024
Closing Soon24 Oct 2024
Tender Amount₹ 7,50,97,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Removal of Hume Pipes Removing all types of Hume pipes and stacking within a lead of 1000 m including Earthwork and Dismantling of Masonry Works as per Technical Specification Clause 202. iii) Above 900mm dia

24

-

-

... More
Dismantling of structures Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202.I) By Manual Means. C)Reinforced Cement Concrete

513.54

-

-

... More
Excavation in Hilly Areas in Soil by mechanical means. Excavation in soil in Hilly Area by mechanical means including cutting and trimming of side slopes and disposing of excavated earth with a lift upto 1.5 m and a lead upto 20 m as per drawing and Technical Specification Clause 1603.1

8835.1

-

-

... More
Construction of Subgrade and Earthen Shoulders Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1.

3131.37

-

-

... More
Granular Sub-base with Well Graded Material (Table 400.1) Construction of granular sub-base two layers of 175 mm(100+75) thick by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. by Grading III Material

1935.76

-

-

... More
Cement Treated Granular Sub Base Providing laying and spreading granulated blast furnace slag on a prepared sub-grade pulverising adding the designed quantitity of cement,to the spread granulated blast furnace slag mixing in place with rotavator grading with the mortar grader and compacting with smooth wheel roller 80-100 kN at OMC to achieve the desired unconfined compressive strength and to form a layer of sub- base/base as per Technical Specifications Clauses 404.3 and 410.4.2.

4537.16

-

-

... More
Cement Treated Granular Base Providing laying and spreading granulated blast furnace slag on a prepared sub-grade pulverising adding the designed quantitity of cement,to the spread granulated blast furnace slag mixing in place with rotavator grading with the mortar grader and compacting with smooth wheel roller 80-100 kN at OMC to achieve the desired unconfined compressive strength and to form a layer of sub- base/base as per Technical Specifications Clauses 404.3 and 410.4.2.

3629.55

-

-

... More
Prime coat(Low porosity) Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502

36295.43

-

-

... More
Tack coat Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared dry and hungry bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503.

36295.43

-

-

... More
Mix Seal Surfacing (Used@8% waste plastic of bitumen content) Providing laying and rolling of close - graded premix surfacing of 25 mm thickness composed of 11.2 mm to 0.09 mm (Type A) or 13.2 mm to 0.09 mm (Type B) agregates using penetration grade bitumen to required line, grade & level to serve as wearing course on a preaviously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 8 - 10 kN static roller and finishing to required level and grades as per Technical Specification Clause 509.

36295.43

-

-

... More
Direction and Place Identification signs with size more than 0.9 sqm size board Providing and erecting direction and place identification retro-\reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on mild steel angle iron posts 75 mm x 75 mm x 6 mm, 2 Nos. firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701

14

-

-

... More
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801

-

-

-

... More
a) 600 mm Equilateral Triangle

22

-

-

... More
b) 600 mm Circular

12

-

-

... More
Road Markers/Road Stud with Lens Reflector Providing and fixing of road stud 100 x 100 mm die cast in aluminium, resistant to corrosive effect of salt and grit, fitted with lense reflectors, installed in concrete or asphaltic surface by drilling holes 30 mm upto a depth of 600 mm and bedded in a suitable bituminous grout or epoxy mortar, all as per BS:873 (Part 4) 1973.

1900

-

-

... More
Painting lines, Dashes, Arrows, etc. on Road in Two Coats on New Work Painting lines, dashes, arrows, etc. on roads in two coats on new work with ready mixed road marking paint conforming to IS:164 on bituminous/concrete surface, including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control as per drawing and Technical Specification Clause 1702

2850

-

-

... More
Providing edge stones on valley side of formation as per drawing and Technical Specification Clause 1608.2.6

840

-

-

... More
Providing and Fixing 'Logo' of PMGSY Project Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1

2

-

-

... More
Kilometre Stone Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703

-

-

-

... More
5th Kilometre Stone (Precast)

1

-

-

... More
Ordinary Kilometre Stone (Precast) :

9

-

-

... More
200 Metre Stone (Precast) :

38

-

-

... More
Providing and Fixing Citizen information Board of PMGSY Project(Steel Tube) Providing and fixing of Citizen's Information Board for PMGSY Project with Logo as per MORD specifications and drawing. Two MS Plates of 1.6 mm thick, top and bottom plate duly welded with MS flat iron 25mm x 5m size on back on edges. The plates will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frames of the plates will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 750mm, 750mm below ground level. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as perdrawing Clause 1701 and Annexure 1700.1

2

-

-

... More
Construction of pucca line drain(428.52m)

-

-

-

... More
Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. I) Ordinary soil (i) upto 3 m depth

395.95

-

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 10 i) Nominal mix 1:3:6

47.14

-

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203. (i) Nominal mix (1:2.5:5)

179.45

-

-

... More
Surface Drains in Soil Construction of unlined surface drains of average cross-sectional area 0.40 sqm in soil to specified lines, grades, levels and dimensions. Excavated material to be used in embankment with a lift upto 3m and lead of 50 m (average lead 25 m) as per Technical Specification Clause 307.(B)Mechanical Means

8480

-

-

... More
Construction of Retaining Wall(25m)

-

-

-

... More
Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. I) Ordinary soil (i) upto 3 m depth

62.5

-

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203. P.C.C grade M 10 i) Nominal mix 1:3:6

56.25

-

-

... More
Stone masonry work in cement mortar in foundation complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203. Stone Masonry in cement mortar (1:4)

130

-

-

... More
Pointing with cement mortar (1:3) on brickwork as per drawing and technical specification Clauses 613.3 and 1204

106.25

-

-

... More
Providing concrete plain / reinforced concrete in substructure for height upto 5m complete as per drawings and technical specifications Clauses 802, 804, 805, 806, 807, 1202 & 1204 of Specification of Rural Roads including curing complete. III. PCC grade M20 Nominal mix (1:2:4)

15

-

-

... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7

37.5

-

-

... More
Fillling in foundation trenches as per drawing and technical specification Clause 305.3.9 (II)Earth filling (For marshy soil)

2.4

-

-

... More
Fillling in foundation trenches as per drawing and technical specification Clause 305.3.9 (I) Sand filling behind breast wall

62.5

-

-

... More
Construction of Breast Wall(25m)

-

-

-

... More
Earthwork in excavation for foundation of structures upto 3 m depth as per drawing and technical specification Clause 1104 includding setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

47.44

-

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203. P.C.C grade M 10 i) Nominal mix 1:3:6

11.63

-

-

... More
Stone masonry work in cement mortar in foundation complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203. Stone Masonry in cement mortar (1:4)

122.06

-

-

... More
Fillling in foundation trenches as per drawing and technical specification Clause 305.3.9 (II)Earth filling (For marshy soil)

39.38

-

-

... More
Fillling in foundation trenches as per drawing and technical specification Clause 305.3.9 (I) Sand filling behind breast wall

39.38

-

-

... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7

37.5

-

-

... More
Pointing with cement mortar (1:3) on brickwork as per drawing and technical specification Clauses 613.3 and 1204

87.93

-

-

... More
Providing concrete plain / reinforced concrete in substructure for height upto 5m complete as per drawings and technical specifications Clauses 802, 804, 805, 806, 807, 1202 & 1204 of Specification of Rural Roads including curing complete. III. PCC grade M20 Nominal mix (1:2:4)

15

-

-

... More
Construction of 1000mm HP CULVERT(20nos.)

-

-

-

... More
Excavation for Structures Earthwork in excavation for foundation of structures upto 3 m depth as per drawing and technical specification Clause 1104 includding setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

806.4

-

-

... More
Fillling in foundation trenches as per drawing and technical specification Clause 305.3.9. I. Sand filling

111.8

-

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203. P.C.C grade M 10 i) Nominal mix 1:3:6

51.6

-

-

... More
Stone masonry work in cement mortar in foundation complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203.

527

-

-

... More
Providing and Laying Reinforced Cement Concrete Pipe NP3 as per design in Single Row Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. (B) 1000 mm dia

150

-

-

... More
Bedding for Pipe Type B (First Class) Bedding. Laying (First Class) bedding on well compacted sand, moorum or approved granular material as per Clause 1105 (ii)

98.4

-

-

... More
Proviing and placing of boulder apron laid in sausage wire crate of specified sizes made of 4 mm dia GI wire net of 100mm x 100mm square mesh including required lapping as directed of wire net, stiching with GI wire strongly, filling up the sausage wire crate with approved stone / laterite boulders of minimum 40 Kg. each properly @ 0.90 cum /cum and stiching the gap with GI wires, closing both ends with GI wire net including lapping all sides as directed, including trimming and preparation of bed by cutting or filling earth as required complete including cost of all materials and labours and all incidential charges in this connection..

69.6

-

-

... More
Construction of 1.5 m Span slab culvert(2nos.)

-

-

-

... More
Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50m, dressing of sides and bottom and backfilling in trenches with excavated suitable material I) Ordinary Soil i) upto 3m depth

359.2

-

-

... More
Providing concrete for plain/ reinforced concrete in open foundation complete as per drawings and technical specifications Clause 802, 803, 1202 &1203 i)PCC Grade M 10, I) Nominal Mix. 1:3:6

21

-

-

... More
Providing Concrete (M-15) for Plain Concrete in open foundations complete as per drawing and Technical specification clause 802, 803, 1202,& 1203 II. PCC grade M15 (i)Nominal mix (1:2:5:5)

171.2

-

-

... More
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 II.RCC grade M25

23.22

-

-

... More
Supplying, fitting and placing HYSD bar reinforcement (Fe 415) in super structure complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202

0.65

-

-

... More
Fillling in foundation trenches as per drawing and technical specification Clause 305.3.9 (II)Earth filling (For marshy soil)

69.54

-

-

... More
Fillling in foundation trenches as per drawing and technical specification Clause 305.3.9 (I)Sand filling

26.08

-

-

... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7

72

-

-

... More
Construction of 2 m Span slab culvert(1no.)

-

-

-

... More
Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50m, dressing of sides and bottom and backfilling in trenches with excavated suitable material I) Ordinary Soil i) upto 3m depth

296.58

-

-

... More
Providing concrete for plain/ reinforced concrete in open foundation complete as per drawings and technical specifications Clause 802, 803, 1202 &1203 i)PCC Grade M 10, I) Nominal Mix. 1:3:6

12.06

-

-

... More
Providing Concrete (M-15) for Plain Concrete in open foundations complete as per drawing and Technical specification clause 802, 803, 1202,& 1203 II. PCC grade M15 (i)Nominal mix (1:2:5:5)

146.79

-

-

... More
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 II.RCC grade M25

12.98

-

-

... More
Supplying, fitting and placing HYSD bar reinforcement (Fe 415) in super structure complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202

0.46

-

-

... More
Fillling in foundation trenches as per drawing and technical specification Clause 305.3.9 (II)Earth filling (For marshy soil)

39

-

-

... More
Fillling in foundation trenches as per drawing and technical specification Clause 305.3.9 (I)Sand filling

19.61

-

-

... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7

36

-

-

... More
Construction of 3 m Span slab culvert(1no.)

-

-

-

... More
Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50m, dressing of sides and bottom and backfilling in trenches with excavated suitable material I) Ordinary Soil i) upto 3m depth

296.58

-

-

... More
Providing concrete for plain/ reinforced concrete in open foundation complete as per drawings and technical specifications Clause 802, 803, 1202 &1203 i)PCC Grade M 10, I) Nominal Mix. 1:3:6

12.06

-

-

... More
Providing Concrete (M-15) for Plain Concrete in open foundations complete as per drawing and Technical specification clause 802, 803, 1202,& 1203 II. PCC grade M15 (i)Nominal mix (1:2:5:5)

146.79

-

-

... More
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 II.RCC grade M25

16.4

-

-

... More
Supplying, fitting and placing HYSD bar reinforcement (Fe 415) in super structure complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202

0.79

-

-

... More
Fillling in foundation trenches as per drawing and technical specification Clause 305.3.9 (II)Earth filling (For marshy soil)

39

-

-

... More
Fillling in foundation trenches as per drawing and technical specification Clause 305.3.9 (I)Sand filling

19.61

-

-

... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7

36

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.