Manipur State Rural Roads Development Agency Tender

View complete overview of Manipur MSRRDA Tender

Manipur State Rural Roads Development Agency - MSRRDA Tender

Works
Civil And Construction
Eprocure
Opening Date8 Aug 2018
Closing Date6 Oct 2018
Tender Amount₹ 4,11,57,000 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Surface Drains in Soil

-

-

-

... More
Construction of unlined surface drains of average cross-sectional area 0.40 sqm in soil to specified lines, grades, levels and dimensions. Excavated material to be used in embankment with a lift upto 3m and lead of 50 m (average lead 25 m) as per Technical Specification Clause 307.

-

-

-

... More
A) Manual Means

1430

-

-

... More
Surface Drains in Ordinary Rock

-

-

-

... More
Construction of unlined surface drains of average cross-sectional area 0.40 sqm in soil to specified lines, grades, levels and dimensions. Excavated material to be used in embankment with a lift upto 3m and lead of 50 m (average lead 25 m) as per Technical Specification Clause 307.

-

-

-

... More
A) Manual Means

875

-

-

... More
Construction of Subgrade and Earthen Shoulders

-

-

-

... More
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1.

1566.18

-

-

... More
Compacting original ground supporting subgrade

-

-

-

... More
Loosening of the ground upto a level of 300 mm below the subgrade level, watered, graded and compacted in layers to meet requirement of Tables 300.1 and 300.2 for subgrade construction as per Technical Specification Clause 303.5.2.

2313.68

-

-

... More
Kilometre Stone

-

-

-

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703

-

-

-

... More
i) Ordinary Kilometer Stone (Precast)

3

-

-

... More
ii) 200 m stone (precast)

10

-

-

... More
Providing and Fixing 'Logo' of PMGSY Project

-

-

-

... More
Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1

2

-

-

... More
Providing and Fixing of Citizen Information Board of PMGSY Project (Steel Tube)

-

-

-

... More
Providing and fixing of Citizen's Information Board for PMGSY Project with Logo as per MORD specifications and drawing. Two MS Plates of 1.6 mm thick, top and bottom plate duly welded with MS flat iron 25mm x 5m size on back on edges. The plates will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frames of the plates will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 750mm, 750mm below ground level. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1

2

-

-

... More
Providing and fixing Maintenance Information Board of PMGSY Project with Logo as per MORD specification and drawing. Two MS plates of 1.6 mm thick, top and bottom plates duly welded with MS flat iron 25mm x 5mm size on back on edges. The plates will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the plate will be welded to 2 nos. 75 mm x 75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M - 15 grade blocks of 600 mm x 600 mm x 750 mm , 750mm below ground level. All MS will be stove enameled on both sides. Lettering and printing arrows, broder etc. will be pained with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1.

1

-

-

... More
Traffic Signs/Retro-reflectorised Traffic Signs

-

-

-

... More
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801

-

-

-

... More
a) 600 mm dia circle

12

-

-

... More
b) 600 mm equilateral triangle

16

-

-

... More
Providing and Fixing PMGSY Logo Board at starting point (Steel Tube)

-

-

-

... More
Providing and fixing of typical PMGSY Logo board as per MORD specifications and drawing. One plate of 1.6mm thick with MS flat 25mm x 5mm size on back on centre. The topmost diamond plate & mid. Plate will be welded to 75mm x 75mm 0f 12 SWG steel plate tube posts & dully embedded to CC 450mm x 450mm x 600mm below GL. Lettering and printing etc. will be with ready mixed synthetic enamel paint of superior.

2

-

-

... More
Direction and Place Identification signs upto 0.90 Sqm Size Board

-

-

-

... More
A. Retro-reflectorised Traffic Signs

-

-

-

... More
Providing and erecting direction and place identification retro-reflectorised sheeting vide clasue 1701.2.3., fixed over aluminium sheeting 2mm thick with area not exceeding 0.90 sqm supported on a mild steel angle iron posts 75 x 75 x 6 mm firmly fixed to the gorund by means of properly designed foundation with M-15 grade cement concrete 450 x 450 x 600mm, 600mm below ground level as per approved drawing and technical specifications Clasuse 1701.

4

-

-

... More
Granular Sub-base with Well Graded Material (Table 400.1)

-

-

-

... More
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.

-

-

-

... More
i) For grading II Material

1542.45

-

-

... More
WBM Grading 3

-

-

-

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 3 as per Technical Specification Clause 405.

-

-

-

... More
By Manual Means

533.93

-

-

... More
Bases & Surface courses (Bituminous)

-

-

-

... More
Prime Coat - Low - porosity

-

-

-

... More
Providing and applying primer coat with Bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70- 1.0 kg/sqm using mechanical means as per Technical Specification Clause 502.

7119

-

-

... More
Tack Coat

-

-

-

... More
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503

7119

-

-

... More
20mm thick Open-Graded Premix Carpet using Bituminous (penetration grade/modified bitumen) Binder

-

-

-

... More
Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508.By Manual Means Bitumen (S-90)

7119

-

-

... More
Seal Coat with Bitumen (S-90)

-

-

-

... More
Providing and laying seal coat with Bitumen for sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510

-

-

-

... More
Case II : Type B (By Manual means)

7119

-

-

... More
Construction of 2.00m span slab culvert (Height - 3.16 m)

-

-

-

... More
Excavation for Structures

-

-

-

... More
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. I) Ordinary soil i) Upto 3 m depth

185.02

-

-

... More
Fillling in foundation trenches as per drawing and technical specification Clauses 305.3.9 II. Earth filling (For marshy soil)

123.35

-

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 10 i) Nominal mix 1:3:6

16.08

-

-

... More
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204. I) P.C.C grade M 15 ii) Nominal mix (1:2.5:5)

132.64

-

-

... More
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 I) R.C.C M 20

6.42

-

-

... More
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 II) R.C.C M 25

7.48

-

-

... More
Supplying, fitting, and placing HYSD bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202

0.89286

-

-

... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7

60

-

-

... More
Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8

41.82

-

-

... More
Construction of Pipe Culvert (NP-3 : 1000mm dia. Dn Hill head wall ht 2.85m), 4 Nos

-

-

-

... More
Excavation for Structures

-

-

-

... More
Earthwork in excavation for foundation of structures upto 3 m depth as per drawing and technical specification Clause 1104 includding setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

325.68

-

-

... More
Plain Cement Concrete M10 (1:3:6 nominal mix) in levelling course below open foundation of Head walls as per drawings & Technical Specification Clause 1109

16.08

-

-

... More
Stone Masonry Work in cement mortar in foundation of Head walls complete as per drawing and technical specification Clasue 1109 A) In 1:4 cement mortar

151.52

-

-

... More
Bedding for Pipe

-

-

-

... More
Laying (First Class) bedding on well compacted sand, moorum or approved granular material as per Clause 1105 (ii)

11.8

-

-

... More
Providing and Laying Reinforced Cement Concrete Pipe NP3 as per design in Single Row

-

-

-

... More
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. (A) 1000 mm dia.

30

-

-

... More
Plastering with Cement Mortar (1:4), 15 mm thick on brick/stone work in substructure as per technical specification

236.4

-

-

... More
Construction of RCC guide posts of 250 mm dia M15 grade cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical RCC posts not to exceed 1 in 500 as per drawing and Technical Specification Clause 1608.2

16

-

-

... More
Construction of Protection Works (Retaining Wall : Height 4.00 m), 2 Nos

-

-

-

... More
Excavation for Structures

-

-

-

... More
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. I) Ordinary soil i) Upto 3 m depth.

134.08

-

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 10 i) Nominal mix 1:3:6

12.18

-

-

... More
Stone masonry in cement mortar for substructure complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204 III) Random Rubble masonry ii) cm 1:4

124.76

-

-

... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7

34

-

-

... More
Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8

92

-

-

... More
Pointing with cement mortar (1:3) on brickwork/stonework as per drawing and technical specification Clauses 613.3 and 1204

105.72

-

-

... More
Construction of Protection Works (Breast Wall : Height 2.50 m), 3 Nos

-

-

-

... More
Excavation for Structures

-

-

-

... More
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 I) Ordinary Soil

88.44

-

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 Nominal mix 1:3:6

11.79

-

-

... More
Stone Masonary in Cement mortar for substructure complete as per drawing & technical spesification clauses 702, 704, 1202 and 1204 II) Course Stone Masonary II Sort iii) cm 1:5

87

-

-

... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing

27

-

-

... More
Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing

52.5

-

-

... More
Pointing with cement mortar (1:3), on brickwork/ stone work in substructure as per technical specification Clause 613.3.

81.78

-

-

... More
CONSTRUCTION OF LINED PUCCA DRAIN WORKS 100m

-

-

-

... More
Earthwork in excavation for foundations of structures as per drawings and technical specifications Clause 307 including setting out construction of shoring and bracing deleterious matter, dressings of sides and bottom and backfilling with approved material (By manual means).

78.75

-

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 I) P.C.C grade M 10 i) Nominal mix 1:3:6

15.75

-

-

... More
Stone masonry in cement mortar in foundation complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204 III)Random Rubble masonry ii) cm 1:4

24

-

-

... More
Plastering with Cement Mortar (1:4), 15 mm thick on brick/stone work in substructure as per technical specification

160

-

-

... More
Maintenance component for 5(five) years after construction (not to be quoted yearwise)

-

-

-

... More
1st year: 102382.42

-

-

-

... More
2nd year: 153573.62

-

-

-

... More
3rd year: 204764.83

-

-

-

... More
4th year: 255956.04

-

-

-

... More
5th year: 307147.25

-

-

-

... More
L036-NH-39 to Chandramani

-

-

-

... More
Setting out

-

-

-

... More
Construction of Job pillers as per Fig. 1600.1 (d) and Technical Specification Clause 1602.4

2

-

-

... More
Surface Drains in Soil

-

-

-

... More
Construction of unlined surface drains of average cross-sectional area 0.40 sqm in soil to specified lines, grades, levels and dimensions. Excavated material to be used in embankment with a lift upto 3m and lead of 50 m (average lead 25 m) as per Technical Specification Clause 307.

-

-

-

... More
A) Manual Means

1499

-

-

... More
Surface Drains in Ordinary Rock

-

-

-

... More
Construction of unlined surface drains of average cross-sectional area 0.40 sqm in soil to specified lines, grades, levels and dimensions. Excavated material to be used in embankment with a lift upto 3m and lead of 50 m (average lead 25 m) as per Technical Specification Clause 307.

-

-

-

... More
A) Manual Means

600

-

-

... More
Construction of Subgrade and Earthen Shoulders

-

-

-

... More
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1.

1675.08

-

-

... More
Compacting original ground supporting subgrade

-

-

-

... More
Loosening of the ground upto a level of 300 mm below the subgrade level, watered, graded and compacted in layers to meet requirement of Tables 300.1 and 300.2 for subgrade construction as per Technical Specification Clause 303.5.2.

2474.55

-

-

... More
Kilometre Stone

-

-

-

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703

-

-

-

... More
i) Ordinary Kilometer Stone (Precast)

3

-

-

... More
ii) 200 m stone (precast)

10

-

-

... More
Providing and Fixing 'Logo' of PMGSY Project

-

-

-

... More
Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1

2

-

-

... More
Providing and Fixing of Citizen Information Board of PMGSY Project (Steel Tube)

-

-

-

... More
Providing and fixing of Citizen's Information Board for PMGSY Project with Logo as per MORD specifications and drawing. Two MS Plates of 1.6 mm thick, top and bottom plate duly welded with MS flat iron 25mm x 5m size on back on edges. The plates will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frames of the plates will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 750mm, 750mm below ground level. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1

2

-

-

... More
Providing and fixing Maintenance Information Board of PMGSY Project with Logo as per MORD specification and drawing. Two MS plates of 1.6 mm thick, top and bottom plates duly welded with MS flat iron 25mm x 5mm size on back on edges. The plates will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the plate will be welded to 2 nos. 75 mm x 75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M - 15 grade blocks of 600 mm x 600 mm x 750 mm , 750mm below ground level. All MS will be stove enameled on both sides. Lettering and printing arrows, broder etc. will be pained with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1.

1

-

-

... More
Traffic Signs/Retro-reflectorised Traffic Signs

-

-

-

... More
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801

-

-

-

... More
a) 600 mm dia circle

10

-

-

... More
b) 600 mm equilateral triangle

6

-

-

... More
Providing and Fixing PMGSY Logo Board at starting point (Steel Tube)

-

-

-

... More
Providing and fixing of typical PMGSY Logo board as per MORD specifications and drawing. One plate of 1.6mm thick with MS flat 25mm x 5mm size on back on centre. The topmost diamond plate & mid. Plate will be welded to 75mm x 75mm 0f 12 SWG steel plate tube posts & dully embedded to CC 450mm x 450mm x 600mm below GL. Lettering and printing etc. will be with ready mixed synthetic enamel paint of superior.

2

-

-

... More
Direction and Place Identification signs upto 0.90 Sqm Size Board

-

-

-

... More
A. Retro-reflectorised Traffic Signs

-

-

-

... More
Providing and erecting direction and place identification retro-reflectorised sheeting vide clasue 1701.2.3., fixed over aluminium sheeting 2mm thick with area not exceeding 0.90 sqm supported on a mild steel angle iron posts 75 x 75 x 6 mm firmly fixed to the gorund by means of properly designed foundation with M-15 grade cement concrete 450 x 450 x 600mm, 600mm below ground level as per approved drawing and technical specifications Clasuse 1701.

4

-

-

... More
Granular Sub-base with Well Graded Material (Table 400.1)

-

-

-

... More
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.

-

-

-

... More
i) For grading II Material

1649.7

-

-

... More
WBM Grading 3

-

-

-

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 3 as per Technical Specification Clause 405.

-

-

-

... More
By Manual Means

571.05

-

-

... More
Bases & Surface courses (Bituminous)

-

-

-

... More
Prime Coat - Low - porosity

-

-

-

... More
Providing and applying primer coat with Bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70- 1.0 kg/sqm using mechanical means as per Technical Specification Clause 502.

7614

-

-

... More
Tack Coat

-

-

-

... More
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503

7614

-

-

... More
20mm thick Open-Graded Premix Carpet using Bituminous (penetration grade/modified bitumen) Binder

-

-

-

... More
Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508.By Manual Means Bitumen (S-90)

7614

-

-

... More
Seal Coat with Bitumen (S-90)

-

-

-

... More
Providing and laying seal coat with Bitumen for sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510

-

-

-

... More
Case II : Type B (By Manual means)

7614

-

-

... More
Construction of 2.00m span slab culvert (Height - 3.16 m) 2nos

-

-

-

... More
Excavation for Structures

-

-

-

... More
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. I) Ordinary soil i) Upto 3 m depth

185.02

-

-

... More
Fillling in foundation trenches as per drawing and technical specification Clauses 305.3.9 II. Earth filling (For marshy soil)

123.35

-

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 10 i) Nominal mix 1:3:6

16.08

-

-

... More
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204. I) P.C.C grade M 15 ii) Nominal mix (1:2.5:5)

132.64

-

-

... More
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 I) R.C.C M 20

6.42

-

-

... More
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 II) R.C.C M 25

7.48

-

-

... More
Supplying, fitting, and placing HYSD bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202

0.89286

-

-

... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7

60

-

-

... More
Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8

41.82

-

-

... More
Construction of Pipe Culvert (NP-3 : 1000mm dia. Dn Hill head wall ht 2.85m), 5 Nos

-

-

-

... More
Excavation for Structures

-

-

-

... More
Earthwork in excavation for foundation of structures upto 3 m depth as per drawing and technical specification Clause 1104 includding setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

407.1

-

-

... More
Plain Cement Concrete M10 (1:3:6 nominal mix) in levelling course below open foundation of Head walls as per drawings & Technical Specification Clause 1109

20.1

-

-

... More
Stone Masonry Work in cement mortar in foundation of Head walls complete as per drawing and technical specification Clasue 1109 A) In 1:4 cement mortar

189.4

-

-

... More
Bedding for Pipe

-

-

-

... More
Laying (First Class) bedding on well compacted sand, moorum or approved granular material as per Clause 1105 (ii)

14.75

-

-

... More
Providing and Laying Reinforced Cement Concrete Pipe NP3 as per design in Single Row

-

-

-

... More
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. (A) 1000 mm dia.

37.5

-

-

... More
Plastering with Cement Mortar (1:4), 15 mm thick on brick/stone work in substructure as per technical specification

295.5

-

-

... More
Construction of RCC guide posts of 250 mm dia M15 grade cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical RCC posts not to exceed 1 in 500 as per drawing and Technical Specification Clause 1608.2

20

-

-

... More
Construction of Protection Works (Retaining Wall : Height 4.00 m), 4 Nos

-

-

-

... More
Excavation for Structures

-

-

-

... More
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. I) Ordinary soil i) Upto 3 m depth.

268.16

-

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 10 i) Nominal mix 1:3:6

24.36

-

-

... More
Stone masonry in cement mortar for substructure complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204 III) Random Rubble masonry ii) cm 1:4

249.52

-

-

... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7

68

-

-

... More
Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8

184

-

-

... More
Pointing with cement mortar (1:3) on brickwork/stonework as per drawing and technical specification Clauses 613.3 and 1204

211.44

-

-

... More
Construction of Protection Works (Breast Wall : Height 2.50 m), 2 Nos

-

-

-

... More
Excavation for Structures

-

-

-

... More
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 I) Ordinary Soil

58.96

-

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 Nominal mix 1:3:6

7.86

-

-

... More
Stone Masonary in Cement mortar for substructure complete as per drawing & technical spesification clauses 702, 704, 1202 and 1204 II) Course Stone Masonary II Sort iii) cm 1:5

58

-

-

... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing

18

-

-

... More
Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing

35

-

-

... More
Pointing with cement mortar (1:3), on brickwork/ stone work in substructure as per technical specification Clause 613.3.

54.52

-

-

... More
CONSTRUCTION OF LINED PUCCA DRAIN WORKS 200m

-

-

-

... More
Earthwork in excavation for foundations of structures as per drawings and technical specifications Clause 307 including setting out construction of shoring and bracing deleterious matter, dressings of sides and bottom and backfilling with approved material (By manual means).

157.5

-

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 I) P.C.C grade M 10 i) Nominal mix 1:3:6

31.5

-

-

... More
Stone masonry in cement mortar in foundation complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204 III)Random Rubble masonry ii) cm 1:4

48

-

-

... More
Plastering with Cement Mortar (1:4), 15 mm thick on brick/stone work in substructure as per technical specification

320

-

-

... More
Maintenance component for 5(five) years after construction (not to be quoted yearwise)

-

-

-

... More
1st year:118569.25

-

-

-

... More
2nd year: 177853.87

-

-

-

... More
3rd year: 237138.5

-

-

-

... More
4th year: 296423.12

-

-

-

... More
5th year: 355707.74

-

-

-

... More
L023-NH-39 Kangpokpi to Maohing

-

-

-

... More
Setting out

-

-

-

... More
Construction of Job pillers as per Fig. 1600.1 (d) and Technical Specification Clause 1602.4

2

-

-

... More
Surface Drains in Soil

-

-

-

... More
Construction of unlined surface drains of average cross-sectional area 0.40 sqm in soil to specified lines, grades, levels and dimensions. Excavated material to be used in embankment with a lift upto 3m and lead of 50 m (average lead 25 m) as per Technical Specification Clause 307.

-

-

-

... More
A) Manual Means

1940

-

-

... More
Surface Drains in Ordinary Rock

-

-

-

... More
Construction of unlined surface drains of average cross-sectional area 0.40 sqm in soil to specified lines, grades, levels and dimensions. Excavated material to be used in embankment with a lift upto 3m and lead of 50 m (average lead 25 m) as per Technical Specification Clause 307.

-

-

-

... More
A) Manual Means

1165

-

-

... More
Construction of Subgrade and Earthen Shoulders

-

-

-

... More
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1.

2288.88

-

-

... More
Compacting original ground supporting subgrade

-

-

-

... More
Loosening of the ground upto a level of 300 mm below the subgrade level, watered, graded and compacted in layers to meet requirement of Tables 300.1 and 300.2 for subgrade construction as per Technical Specification Clause 303.5.2.

3381.3

-

-

... More
Kilometre Stone

-

-

-

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703

-

-

-

... More
i) Ordinary Kilometer Stone (Precast)

4

-

-

... More
ii) 200 m stone (precast)

14

-

-

... More
Providing and Fixing 'Logo' of PMGSY Project

-

-

-

... More
Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1

2

-

-

... More
Providing and Fixing of Citizen Information Board of PMGSY Project (Steel Tube)

-

-

-

... More
Providing and fixing of Citizen's Information Board for PMGSY Project with Logo as per MORD specifications and drawing. Two MS Plates of 1.6 mm thick, top and bottom plate duly welded with MS flat iron 25mm x 5m size on back on edges. The plates will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frames of the plates will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 750mm, 750mm below ground level. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1

2

-

-

... More
Providing and fixing Maintenance Information Board of PMGSY Project

-

-

-

... More
Providing and fixing Maintenance Information Board of PMGSY Project with Logo as per MORD specification and drawing. Two MS plates of 1.6 mm thick, top and bottom plates duly welded with MS flat iron 25mm x 5mm size on back on edges. The plates will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the plate will be welded to 2 nos. 75 mm x 75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M - 15 grade blocks of 600 mm x 600 mm x 750 mm , 750mm below ground level. All MS will be stove enameled on both sides. Lettering and printing arrows, broder etc. will be pained with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1.

1

-

-

... More
Traffic Signs/Retro-reflectorised Traffic Signs

-

-

-

... More
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801

-

-

-

... More
a) 600 mm dia circle

12

-

-

... More
b) 600 mm equilateral triangle

16

-

-

... More
Providing and Fixing PMGSY Logo Board at starting point (Steel Tube)

-

-

-

... More
Providing and fixing of typical PMGSY Logo board as per MORD specifications and drawing. One plate of 1.6mm thick with MS flat 25mm x 5mm size on back on centre. The topmost diamond plate & mid. Plate will be welded to 75mm x 75mm 0f 12 SWG steel plate tube posts & dully embedded to CC 450mm x 450mm x 600mm below GL. Lettering and printing etc. will be with ready mixed synthetic enamel paint of superior.

2

-

-

... More
Direction and Place Identification signs upto 0.90 Sqm Size Board

-

-

-

... More
A. Retro-reflectorised Traffic Signs

-

-

-

... More
Providing and erecting direction and place identification retro-reflectorised sheeting vide clasue 1701.2.3., fixed over aluminium sheeting 2mm thick with area not exceeding 0.90 sqm supported on a mild steel angle iron posts 75 x 75 x 6 mm firmly fixed to the gorund by means of properly designed foundation with M-15 grade cement concrete 450 x 450 x 600mm, 600mm below ground level as per approved drawing and technical specifications Clasuse 1701.

4

-

-

... More
Granular Sub-base with Well Graded Material (Table 400.1)

-

-

-

... More
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.

-

-

-

... More
i) For grading II Material

2254.2

-

-

... More
WBM Grading 3

-

-

-

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 3 as per Technical Specification Clause 405.

-

-

-

... More
By Manual Means

780.3

-

-

... More
Bases & Surface courses (Bituminous)

-

-

-

... More
Prime Coat - Low - porosity

-

-

-

... More
Providing and applying primer coat with Bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70- 1.0 kg/sqm using mechanical means as per Technical Specification Clause 502.

10404

-

-

... More
Tack Coat

-

-

-

... More
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503

10404

-

-

... More
20mm thick Open-Graded Premix Carpet using Bituminous (penetration grade/modified bitumen) Binder

-

-

-

... More
Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508.By Manual Means Bitumen (S-90)

10404

-

-

... More
Seal Coat with Bitumen (S-90)

-

-

-

... More
Providing and laying seal coat with Bitumen for sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510

-

-

-

... More
Case II : Type B (By Manual means)

10404

-

-

... More
Construction of 2.00m span slab culvert (Height - 3.16 m) 2nos

-

-

-

... More
Excavation for Structures

-

-

-

... More
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. I) Ordinary soil i) Upto 3 m depth

185.02

-

-

... More
Fillling in foundation trenches as per drawing and technical specification Clauses 305.3.9 II. Earth filling (For marshy soil)

61.67

-

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 10 i) Nominal mix 1:3:6

16.08

-

-

... More
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204. I) P.C.C grade M 15 ii) Nominal mix (1:2.5:5)

132.64

-

-

... More
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 I) R.C.C M 20

6.42

-

-

... More
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 II) R.C.C M 25

7.48

-

-

... More
Supplying, fitting, and placing HYSD bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202

0.89286

-

-

... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7

60

-

-

... More
Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8

41.82

-

-

... More
Construction of Pipe Culvert (NP-3 : 1000mm dia. Dn Hill head wall ht 2.85m), 5 Nos

-

-

-

... More
Excavation for Structures

-

-

-

... More
Earthwork in excavation for foundation of structures upto 3 m depth as per drawing and technical specification Clause 1104 includding setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

407.1

-

-

... More
Plain Cement Concrete M10 (1:3:6 nominal mix) in levelling course below open foundation of Head walls as per drawings & Technical Specification Clause 1109

20.1

-

-

... More
Stone Masonry Work in cement mortar in foundation of Head walls complete as per drawing and technical specification Clasue 1109 A) In 1:4 cement mortar

189.4

-

-

... More
Bedding for Pipe

-

-

-

... More
Laying (First Class) bedding on well compacted sand, moorum or approved granular material as per Clause 1105 (ii)

14.75

-

-

... More
Providing and Laying Reinforced Cement Concrete Pipe NP3 as per design in Single Row

-

-

-

... More
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. (A) 1000 mm dia.

37.5

-

-

... More
Plastering with Cement Mortar (1:4), 15 mm thick on brick/stone work in substructure as per technical specification

295.5

-

-

... More
Construction of RCC guide posts of 250 mm dia M15 grade cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical RCC posts not to exceed 1 in 500 as per drawing and Technical Specification Clause 1608.2

20

-

-

... More
Construction of Protection Works (Retaining Wall : Height 4.00 m), 4 Nos

-

-

-

... More
Excavation for Structures

-

-

-

... More
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. I) Ordinary soil i) Upto 3 m depth.

268.16

-

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 10 i) Nominal mix 1:3:6

24.36

-

-

... More
Stone masonry in cement mortar for substructure complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204 III) Random Rubble masonry ii) cm 1:4

249.52

-

-

... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7

68

-

-

... More
Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8

184

-

-

... More
Pointing with cement mortar (1:3) on brickwork/stonework as per drawing and technical specification Clauses 613.3 and 1204

211.44

-

-

... More
Construction of Protection Works (Breast Wall : Height 2.50 m), 3 Nos

-

-

-

... More
Excavation for Structures

-

-

-

... More
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 I) Ordinary Soil

88.44

-

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 Nominal mix 1:3:6

11.79

-

-

... More
Stone Masonary in Cement mortar for substructure complete as per drawing & technical spesification clauses 702, 704, 1202 and 1204 II) Course Stone Masonary II Sort iii) cm 1:5

87

-

-

... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing

27

-

-

... More
Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing

52.5

-

-

... More
Pointing with cement mortar (1:3), on brickwork/ stone work in substructure as per technical specification Clause 613.3.

81.78

-

-

... More
CONSTRUCTION OF LINED PUCCA DRAIN WORKS 200m

-

-

-

... More
Earthwork in excavation for foundations of structures as per drawings and technical specifications Clause 307 including setting out construction of shoring and bracing deleterious matter, dressings of sides and bottom and backfilling with approved material (By manual means).

315

-

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 I) P.C.C grade M 10 i) Nominal mix 1:3:6

63

-

-

... More
Stone masonry in cement mortar in foundation complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204 III)Random Rubble masonry ii) cm 1:4

96

-

-

... More
Plastering with Cement Mortar (1:4), 15 mm thick on brick/stone work in substructure as per technical specification

640

-

-

... More
Maintenance component for 5(five) years after construction (not to be quoted yearwise)

-

-

-

... More
1st year:153199.59

-

-

-

... More
2nd year: 229799.39

-

-

-

... More
3rd year: 306399.19

-

-

-

... More
4th year: 382998.99

-

-

-

... More
5th year: 459598.78

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.