Manipur State Rural Roads Development Agency Tender
View complete overview of Manipur MSRRDA Tender
Manipur State Rural Roads Development Agency - MSRRDA Tender
Civil And Construction
Road Construction
Eprocure
Opening Date4 Aug 2018
Closing Date6 Oct 2018
Tender Amount₹ 2,06,42,000
Costs
EMD
₹ 4,13,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2018_CESQC_66217_52Bid Award Id
ViewTender No
5/16/2018-MSRRDA/Ph-XI/B-IITender Authority
Manipur State Rural Roads Development Agency ViewPurchaser Address
-Website
http://pmgsytenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Construction of Embankment with Material Obtained from Borrow Pits
Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5
1162.8
-
-
... More
Construction of Subgrade and Earthen Shoulders
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1.
For Shoulders & Subgrade
1998
-
-
... More
Kilometre Stone
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703
-
-
-
... More
Ordinary Kilometer Stone (Precast)
2
-
-
... More
200 m stone (precast)
6
-
-
... More
Providing and Fixing 'Logo' of PMGSY Project
Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1
1
-
-
... More
Providing and Fixing of Citizen Information Board of PMGSY Project (Steel Tube)
Providing and fixing of Citizen's Information Board for PMGSY Project with Logo as per MORD specifications and drawing. Two MS Plates of 1.6 mm thick, top and bottom plate duly welded with MS flat iron 25mm x 5m size on back on edges. The plates will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frames of the plates will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 750mm, 750mm below ground level. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1
1
-
-
... More
Providing and Fixing Maintenance Information Board of PMGSY Project
Providing and fixing of maintenance Information Board for PMGSY Project with Logo as per MORD specifications and drawing. Two MS Plates of 1.6 mm thick, top and bottom plate duly welded with MS flat iron 25mm x 5 mm size on back on edges. The plates will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the plates will be welded to 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 750mm, 750mm below ground level. All M.S. will be stove enamelled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing clause 1701 and Annexure 1700.1
1
-
-
... More
Traffic Signs/Retro-reflectorised Traffic Signs
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801
-
-
-
... More
a) 600 mm dia circle
2
-
-
... More
b) 600 mm equilateral triangle
2
-
-
... More
Providing and Fixing PMGSY Logo Board at starting point (Steel Tube)
Providing and fixing of typical PMGSY Logo board as per MORD specifications and drawing. One plate of 1.6mm thick with MS flat 25mm x 5mm size on back on centre. The topmost diamond plate & mid. Plate will be welded to 75mm x 75mm 0f 12 SWG steel plate tube posts & dully embedded to CC 450mm x 450mm x 600mm below GL. Lettering and printing etc. will be with ready mixed synthetic enamel paint of superior.
1
-
-
... More
Direction and Place Identification signs upto 0.90 Sqm Size Board
A. Retro-reflectorised Traffic Signs
Providing and erecting direction and place identification retro-reflectorised sheeting vide clasue 1701.2.3., fixed over aluminium sheeting 2mm thick with area not exceeding 0.90 sqm supported on a mild steel angle iron posts 75 x 75 x 6 mm firmly fixed to the gorund by means of properly designed foundation with M-15 grade cement concrete 450 x 450 x 600mm, 600mm below ground level as per approved drawing and technical specifications Clasuse 1701
1
-
-
... More
Granular sub-base/base/surface course with local materials (Table 400.13) by mix in place method normal construction of granular sub-base by providing local material spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at once and compacting with smooth wheel roller to achieve the desired density complete as per Clause 401.4 as per Technical Specification Clause 408. (i) Using naturally occuring gravel
936
-
-
... More
WBM Grading 3 Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 3 as per Technical Specification Clause 405. A) By Manual Means
324
-
-
... More
Prime coat : Low porosity
Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502. A) By Manual Means
4320
-
-
... More
Tack Coat
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503. A) By Manual Means
4320
-
-
... More
20 mm thick Open Graded Premix Carpet using Bitumen Emulsion as per Technical Specification Clause 508.2
Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508.
4320
-
-
... More
Seal Coat with Bitumen Emulsion Seal Coat Type (MS grade)
Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510.Case II : Type B (By Manual means)
4320
-
-
... More
Construction of 1000mm Pipe Culvert(Height-2.465m)2nos.
-
-
-
... More
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50m, dressing of sides and bottom and backfilling in trenches with excavated suitable material
172.4
-
-
... More
Plain Cement Concrete M10 (1:3:6 nominal mix) in levelling course below open foundation of Head walls as per drawings & Technical Specification Clause 1109
13.78
-
-
... More
Stone Masonry Work in cement mortar in foundation of Head walls complete as per drawing and technical specification Clasue 1109. (A) In 1:4 cement mortar
53.8
-
-
... More
Bedding for Pipe
Type A (Concrete Cradle) Bedding Laying concrete cradle bedding with M15 Grade Cement Concrete as per Clause 1105 (i)
14.06
-
-
... More
Providing and Laying Reinforced Cement Concrete Pipe NP3 as per design in Single Row Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. (B) 1000mm dia.
15
-
-
... More
Plastering with Cement Mortar (1:4), 15 mm thick on brickwork in substructure as per technical specification
64.06
-
-
... More
Construction of 6m span RCC Slab Culvert 3.61 ht.)(1no)
-
-
-
... More
Excavation for Structures
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. I) Ordinary Soil (i) Upto 3m depth.
213.4
-
-
... More
Fillling in foundation trenches as per drawing and technical specification Clauses 305.3.9 II. Earth filling (For marshy soil)
71.13
-
-
... More
Providing concrete for plain/ reinforced concrete in open foundation complete as per drawings and technical specifications Clause 802, 803, 1202 &1203 i)PCC Grade M 10, I) Nominal Mix. 1:3:6
16.43
-
-
... More
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 i) PCC M 15 i) Nominal mix (1:2.5:5)
183.62
-
-
... More
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 III) R.C.C grade M 20
5.57
-
-
... More
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 II. RCC Grade M 25
19.58
-
-
... More
Drainage spouts complete as per drawing and technical specifications Clause 1209
6
-
-
... More
Providing and laying cement concrete wearing course M 30 grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3
2.55
-
-
... More
Supplying, fitting, and placing HYSD bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202
1.71
-
-
... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
38
-
-
... More
Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8
52.7
-
-
... More
Maintenance component for 5(five) years after construction (not to be quoted yearwise)
-
-
-
... More
1st year (in INR): 82169.15
-
-
-
... More
2nd year (in INR): 123253.72
-
-
-
... More
3rd year (in INR): 164338.29
-
-
-
... More
4th year (in INR): 205422.87
-
-
-
... More
5th year (in INR): 246507.44
-
-
-
... More
B) Sonapur(Mayai Leikai) to Lama Bhutangkhal(Lalpani)
Setting out
Construction of reference pillars as per Fig. 1600.1 (b) as per drawing and Technical Specification Clause 1602.1
0.64
-
-
... More
Construction of Job pillars as per Fig. 1600.1 (d) and Technical Specification Clause 1602.4
1
-
-
... More
Surface Drains in Soil
Construction of unlined surface drains of average cross-sectional area 0.40 sqm in soil to specified lines, grades, levels and dimensions. Excavated material to be used in embankment with a lift upto 3m and lead of 50 m (average lead 25 m) as per Technical Specification Clause 307.a) Manual Means
640
-
-
... More
Excavation in Hilly Areas in Soil by mechanical means
Excavation in soil in Hilly Area by mechanical means including cutting and trimming of side slopes and disposing of excavated earth with a lift upto 1.5 m and a lead upto 20 m as per Technical Specification Clause 1603.1
342
-
-
... More
Construction of Subgrade and Earthen Shoulders
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1.
For Shoulders & Subgrade
888
-
-
... More
Kilometre Stone
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703
-
-
-
... More
200 m stone (precast)
3
-
-
... More
Providing and Fixing 'Logo' of PMGSY Project
Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1
1
-
-
... More
Providing and Fixing of Citizen Information Board of PMGSY Project (Steel Tube)
Providing and fixing of Citizen's Information Board for PMGSY Project with Logo as per MORD specifications and drawing. Two MS Plates of 1.6 mm thick, top and bottom plate duly welded with MS flat iron 25mm x 5m size on back on edges. The plates will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frames of the plates will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 750mm, 750mm below ground level. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1
1
-
-
... More
Providing and Fixing Maintenance Information Board of PMGSY Project
Providing and fixing of maintenance Information Board for PMGSY Project with Logo as per MORD specifications and drawing. Two MS Plates of 1.6 mm thick, top and bottom plate duly welded with MS flat iron 25mm x 5 mm size on back on edges. The plates will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the plates will be welded to 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 750mm, 750mm below ground level. All M.S. will be stove enamelled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing clause 1701 and Annexure 1700.1
1
-
-
... More
Traffic Signs/Retro-reflectorised Traffic Signs
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801
-
-
-
... More
a) 600 mm dia circle
2
-
-
... More
b) 600 mm equilateral triangle
2
-
-
... More
Providing and Fixing PMGSY Logo Board at starting point (Steel Tube)
Providing and fixing of typical PMGSY Logo board as per MORD specifications and drawing. One plate of 1.6mm thick with MS flat 25mm x 5mm size on back on centre. The topmost diamond plate & mid. Plate will be welded to 75mm x 75mm 0f 12 SWG steel plate tube posts & dully embedded to CC 450mm x 450mm x 600mm below GL. Lettering and printing etc. will be with ready mixed synthetic enamel paint of superior.
1
-
-
... More
Direction and Place Identification signs upto 0.90 Sqm Size Board
A. Retro-reflectorised Traffic Signs
Providing and erecting direction and place identification retro-reflectorised sheeting vide clasue 1701.2.3., fixed over aluminium sheeting 2mm thick with area not exceeding 0.90 sqm supported on a mild steel angle iron posts 75 x 75 x 6 mm firmly fixed to the gorund by means of properly designed foundation with M-15 grade cement concrete 450 x 450 x 600mm, 600mm below ground level as per approved drawing and technical specifications Clasuse 1701
1
-
-
... More
Granular sub-base/base/surface course with local materials (Table 400.13) by mix in place method normal construction of granular sub-base by providing local material spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at once and compacting with smooth wheel roller to achieve the desired density complete as per Clause 401.4 as per Technical Specification Clause 408. (i) Using naturally occuring gravel
416
-
-
... More
WBM Grading 3 Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 3 as per Technical Specification Clause 405. A) By Manual Means
144
-
-
... More
Prime coat : Low porosity
Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502. A) By Manual Means
1920
-
-
... More
Tack Coat
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503. A) By Manual Means
1920
-
-
... More
20 mm thick Open Graded Premix Carpet using Bitumen Emulsion as per Technical Specification Clause 508.2
Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508.
1920
-
-
... More
Seal Coat with Bitumen Emulsion Seal Coat Type (MS grade)
Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510.Case II : Type B (By Manual means)
1920
-
-
... More
Construction of 1000mm Pipe Culvert(Height-2.465m)3nos.
-
-
-
... More
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50m, dressing of sides and bottom and backfilling in trenches with excavated suitable material
258.6
-
-
... More
Plain Cement Concrete M10 (1:3:6 nominal mix) in levelling course below open foundation of Head walls as per drawings & Technical Specification Clause 1109
20.67
-
-
... More
Stone Masonry Work in cement mortar in foundation of Head walls complete as per drawing and technical specification Clasue 1109. (A) In 1:4 cement mortar
80.7
-
-
... More
Bedding for Pipe
Type A (Concrete Cradle) Bedding Laying concrete cradle bedding with M15 Grade Cement Concrete as per Clause 1105 (i)
21.09
-
-
... More
Providing and Laying Reinforced Cement Concrete Pipe NP3 as per design in Single Row Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. (B) 1000mm dia.
22.5
-
-
... More
Plastering with Cement Mortar (1:4), 15 mm thick on brickwork in substructure as per technical specification
96.09
-
-
... More
Construction of Retaining Wall : Height 2.5m(4nos.)
-
-
-
... More
Excavation for Structures
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50m, dressing of sides and bottom and backfilling in trenches with excavated suitable material I) Ordinary Soil i) upto 3m depth
135.4
-
-
... More
Providing concrete for plain/ reinforced concrete in open foundation complete as per drawings and technical specifications Clause 802, 803, 1202 &1203 i)PCC Grade M 10, I) Nominal Mix. 1:3:6
15.48
-
-
... More
Stone masonry in cement mortar for substructure complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204 III) Random rubble masonry ii) In 1:4 cement mortar
109.6
-
-
... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
52
-
-
... More
Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8
70
-
-
... More
Pointing with cement mortar (1:3) on brickwork as per drawing and technical sepecification clauses 613.3 and 1204
175.68
-
-
... More
Maintenance component for 5(five) years after construction (not to be quoted yearwise)
-
-
-
... More
1st year (in INR): 41698.2
-
-
-
... More
2nd year (in INR): 62547.3
-
-
-
... More
3rd year (in INR): 83396.4
-
-
-
... More
4th year (in INR): 104245.5
-
-
-
... More
5th year (in INR): 125094.6
-
-
-
... More
C) Champanagar to Sonapur
Setting out
Construction of reference pillars as per Fig. 1600.1 (b) as per drawing and Technical Specification Clause 1602.1
1
-
-
... More
Construction of Job pillars as per Fig. 1600.1 (d) and Technical Specification Clause 1602.4
1
-
-
... More
Surface Drains in Soil
Construction of unlined surface drains of average cross-sectional area 0.40 sqm in soil to specified lines, grades, levels and dimensions. Excavated material to be used in embankment with a lift upto 3m and lead of 50 m (average lead 25 m) as per Technical Specification Clause 307.a) Manual Means
1150
-
-
... More
Excavation in Hilly Areas in Soil by mechanical means
Excavation in soil in Hilly Area by mechanical means including cutting and trimming of side slopes and disposing of excavated earth with a lift upto 1.5 m and a lead upto 20 m as per Technical Specification Clause 1603.1
305.1
-
-
... More
Construction of Embankment with Material Obtained from Borrow Pits
Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5
3700.8
-
-
... More
Construction of Subgrade and Earthen Shoulders
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1.
For Shoulders & Subgrade
1595.63
-
-
... More
Kilometre Stone
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703
-
-
-
... More
Ordinary Kilometer Stone (Precast)
2
-
-
... More
200 m stone (precast)
4
-
-
... More
Providing and Fixing 'Logo' of PMGSY Project
Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1
1
-
-
... More
Providing and Fixing of Citizen Information Board of PMGSY Project (Steel Tube)
Providing and fixing of Citizen's Information Board for PMGSY Project with Logo as per MORD specifications and drawing. Two MS Plates of 1.6 mm thick, top and bottom plate duly welded with MS flat iron 25mm x 5m size on back on edges. The plates will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frames of the plates will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 750mm, 750mm below ground level. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1
1
-
-
... More
Providing and Fixing Maintenance Information Board of PMGSY Project
Providing and fixing of maintenance Information Board for PMGSY Project with Logo as per MORD specifications and drawing. Two MS Plates of 1.6 mm thick, top and bottom plate duly welded with MS flat iron 25mm x 5 mm size on back on edges. The plates will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the plates will be welded to 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 750mm, 750mm below ground level. All M.S. will be stove enamelled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing clause 1701 and Annexure 1700.1
1
-
-
... More
Traffic Signs/Retro-reflectorised Traffic Signs
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801
-
-
-
... More
a) 600 mm dia circle
1
-
-
... More
b) 600 mm equilateral triangle
1
-
-
... More
Providing and Fixing PMGSY Logo Board at starting point (Steel Tube)
Providing and fixing of typical PMGSY Logo board as per MORD specifications and drawing. One plate of 1.6mm thick with MS flat 25mm x 5mm size on back on centre. The topmost diamond plate & mid. Plate will be welded to 75mm x 75mm 0f 12 SWG steel plate tube posts & dully embedded to CC 450mm x 450mm x 600mm below GL. Lettering and printing etc. will be with ready mixed synthetic enamel paint of superior.
1
-
-
... More
Direction and Place Identification signs upto 0.90 Sqm Size Board
A. Retro-reflectorised Traffic Signs
Providing and erecting direction and place identification retro-reflectorised sheeting vide clasue 1701.2.3., fixed over aluminium sheeting 2mm thick with area not exceeding 0.90 sqm supported on a mild steel angle iron posts 75 x 75 x 6 mm firmly fixed to the gorund by means of properly designed foundation with M-15 grade cement concrete 450 x 450 x 600mm, 600mm below ground level as per approved drawing and technical specifications Clasuse 1701
1
-
-
... More
Granular sub-base/base/surface course with local materials (Table 400.13) by mix in place method normal construction of granular sub-base by providing local material spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at once and compacting with smooth wheel roller to achieve the desired density complete as per Clause 401.4 as per Technical Specification Clause 408. (i) Using naturally occuring gravel
747.5
-
-
... More
WBM Grading 3 Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 3 as per Technical Specification Clause 405. A) By Manual Means
258.75
-
-
... More
Prime coat : Low porosity
Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502. A) By Manual Means
3450
-
-
... More
Tack Coat
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503. A) By Manual Means
3450
-
-
... More
20 mm thick Open Graded Premix Carpet using Bitumen Emulsion as per Technical Specification Clause 508.2
Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508.
3450
-
-
... More
Seal Coat with Bitumen Emulsion Seal Coat Type (MS grade)
Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510.Case II : Type B (By Manual means)
3450
-
-
... More
Construction of 1000mm Pipe Culvert(Height-2.465m)2nos.
-
-
-
... More
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50m, dressing of sides and bottom and backfilling in trenches with excavated suitable material
172.4
-
-
... More
Plain Cement Concrete M10 (1:3:6 nominal mix) in levelling course below open foundation of Head walls as per drawings & Technical Specification Clause 1109
13.78
-
-
... More
Stone Masonry Work in cement mortar in foundation of Head walls complete as per drawing and technical specification Clasue 1109. (A) In 1:4 cement mortar
53.8
-
-
... More
Bedding for Pipe
Type A (Concrete Cradle) Bedding Laying concrete cradle bedding with M15 Grade Cement Concrete as per Clause 1105 (i)
14.06
-
-
... More
Providing and Laying Reinforced Cement Concrete Pipe NP3 as per design in Single Row Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. (B) 1000mm dia.
15
-
-
... More
Plastering with Cement Mortar (1:4), 15 mm thick on brickwork in substructure as per technical specification
64.06
-
-
... More
Maintenance component for 5(five) years after construction (not to be quoted yearwise)
-
-
-
... More
1st year (in INR): 63789.79
-
-
-
... More
2nd year (in INR): 95684.68
-
-
-
... More
3rd year (in INR): 127579.58
-
-
-
... More
4th year (in INR): 159474.47
-
-
-
... More
5th year (in INR): 191369.37
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements