Manipur State Power Company Limited Tender
View complete overview of Manipur MSPDCL Tender
Manipur State Power Company Limited - MSPDCL Tender
Civil And Construction
Civil Works Others
Eprocure
Opening Date2 Jan 2021
Closing Date27 Jan 2021
Tender AmountRefer Documents
Costs
EMD
₹ 5,00,000Document Cost
₹ 10,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_MSPDC_1226_1Bid Award Id
ViewTender No
2/209(IPDS-SS)2020-MSPDCL-TECHTender Authority
Manipur State Power Company Limited ViewPurchaser Address
-Website
http://https://www.mspdcl.com
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Galvanised Pole top bracket
68
-
-
Galvanised Clamp for Pole top Bracket
136
-
-
Galvanised Cross arm(75X40)mm
68
-
-
Galvanised Back clamp for X-arm
68
-
-
Galvanised 2x2.2m D.P. channel X-arm (75X40)mm
14
-
-
11 KV Disc. Composite/Polymer Insulator (Complete set i/c Tension clamps,Hardware)
87
-
-
11 KV Pin Composite/Polymer Insulator (Complete with Pin )
243
-
-
ACSR Conductor (Rabbit)
15.12
-
-
11 KV AB Switch/G.O. Switch with Galvanised X-arm etc.
4
-
-
Stay Set complete with stay wire, base plate, stay rod etc.
72
-
-
Galvanised Stay Clamp
72
-
-
Galvanised Bracing for D.P.structure, 50X50X6mm M.S. Angle
14
-
-
Galvanised Clamp for D.P. Bracing
56
-
-
Galvanised Anti climbing device complete
96
-
-
Earthing set complete with G.I. wire
82
-
-
Guarding at crossing with G.I. wire
4.8
-
-
Nuts, Bolts, MS flat as support for item No. 3 jointing sleeves etc.@7kg/km
34
-
-
Al. Binding wire, UPG clamps etc. @10 kg/km
48
-
-
Sundries like pole painting Danger plate etc.
4.8
-
-
Installation of Distribution Transformer
-
-
-
Installation of New Distribution Transformer of 250 KVA (10 Nos.)
-
-
-
9.0 m Steel Tubular Pole (410:SP-31)
20
-
-
Galvanised Channel 100X50,@ 7.9 Kg/m 2.8X2 for supporting Transformer
10
-
-
Galvanised Clamp for transformer base channel for M.S. flat 50X8mm@3.1Kg/m 0.27mX2.
20
-
-
Galvanised Channel 100X50,@7.9 Kg/m 2.8X2 for D.P. X-arm
10
-
-
Galvanised Channel 100X50,@7.9 Kg/m 0.46X2 for supporting of item 2
10
-
-
Galvanised Channel 75X40,@5.7Kg/m 2X2.8m for HG fuse unit & A.B. switch
20
-
-
Galvanised Clamp for A.B. switch/HG Fuse/DO Fuse, 50X8mm @ 3.1Kg/m 0.23mX2=0.46m.
80
-
-
Galvanised Channel 75X40,@5.7Kg/m 2X0.5m for supporting H.G. fuse main channel X-arm
30
-
-
Galvanised Angle (50X50X6)mm 2.8X2 @ 4.5 Kg/m transformer belting and Angle (35X35X5),0.46X2 @ 2.6 Kg/m. Transformer belting support.
10
-
-
Galvanised Clamp for transformer belting
20
-
-
Distribution transformer 250 KVA as per IS:1180(2014) level-II
10
-
-
A.B.Switch
10
-
-
Horn gap fuse unit/D.O. fuse, 3 -Ph
10
-
-
DTR Cubicle for DTRs (Comprising of requisite and adequate ratings of MCCBs/MCBs for LT protection in incomer and outgoing along with accessories required.
10
-
-
1.1KV grade, 3½ core 120 Sq.mm PVC insulated aluminium power cable
100
-
-
D.B.box Galvanised cross arm of M.S. Angle 35X35X5mm @ 2.6Kg/m 2.8X2 = 5.6m
10
-
-
Galvanised Clamp for DB Box Cross arm
20
-
-
Sub-Station Earthing (set of 3 Earthing Pipe)
10
-
-
3 phase Tri-vector Energy meter comprising of IS 14697-1999 with Kiosk
10
-
-
Danger board & Sign Board
10
-
-
11 KV lightening arrestor
30
-
-
11 KV Disc. Composite/Polymer Insulator (Complete set i/c Tension clamps,Hardware)
30
-
-
Bolts,Nuts,clamps etc.@5kg/DTR
50
-
-
Sundries, Pole painting etc.
10
-
-
Installation of New Distribution Transformer of 100 KVA (4 Nos)
-
-
-
9.0 m Steel Tubular Pole (410:SP-31)
8
-
-
Galvanised Channel 100X50,@ 7.9 Kg/m 2.8X2 for supporting Transformer
4
-
-
Galvanised Clamp for transformer base channel for M.S. flat 50X8mm@3.1Kg/m 0.27mX2.
8
-
-
Galvanised Channel 100X50,@7.9 Kg/m 2.8X2 for D.P. X-arm
4
-
-
Galvanised Channel 100X50,@7.9 Kg/m 0.46X2 for supporting of item 2
4
-
-
Galvanised Channel 75X40,@5.7Kg/m 2X2.8m for HG fuse unit & A.B. switch
8
-
-
Galvanised Clamp for A.B. switch/HG Fuse/DO Fuse, 50X8mm @ 3.1Kg/m 0.23mX2=0.46m.
32
-
-
Galvanised Channel 75X40,@5.7Kg/m 2X0.5m for supporting H.G. fuse main channel X-arm
12
-
-
Galvanised Angle (50X50X6)mm 2.8X2 @ 4.5 Kg/m transformer belting and Angle (35X35X5),0.46X2 @ 2.6 Kg/m. Transformer belting support.
4
-
-
Galvanised Clamp for transformer belting
8
-
-
Distribution transformer 100 KVA as per IS:1180(2014) level-II
4
-
-
A.B.Switch
4
-
-
Horn gap fuse unit/D.O. fuse, 3 -Ph
4
-
-
DTR Cubicle for DTRs (Comprising of requisite and adequate ratings of MCCBs/MCBs for LT protection in incomer and outgoing along with accessories required.
4
-
-
1.1KV grade, 3½ core 120 Sq.mm PVC insulated aluminium power cable
40
-
-
D.B.box Galvanised cross arm of M.S. Angle 35X35X5mm @ 2.6Kg/m 2.8X2 = 5.6m
4
-
-
Galvanised Clamp for DB Box Cross arm
8
-
-
Sub-Station Earthing (set of 3 Earthing Pipe)
4
-
-
3 phase Tri-vector Energy meter comprising of IS 14697-1999 with Kiosk
4
-
-
Danger board & Sign Board
4
-
-
11 KV lightening arrestor
12
-
-
11 KV Disc. Composite/Polymer Insulator (Complete set i/c Tension clamps,Hardware)
12
-
-
Bolts,Nuts,clamps etc.@5kg/DTR
20
-
-
Sundries, Pole painting etc.
4
-
-
Arial Bunched Cable
-
-
-
New LT Line Using 3 phase 4 wire with AB Cable (3x70+1x50)Sq.mm (6.0 Km.)
-
-
-
8.0 m S.T.P.(410:SP-14)
168
-
-
M.S. cross arm (75X40) mm, 500 mm long
168
-
-
Back clamp for cross arm
168
-
-
Dead end fittings for AB Cable with Insulated messenger wire complete with Eye hook as per Construction Standards :
24
-
-
Suspension fittings for AB Cable with Insulated messenger wire complete with Eye hook as per Construction Standards :
144
-
-
AB Cable (3x70+1x50)Sq.mm with insulated messenger/Neutral
6
-
-
Insulation piercing connector suitable for AB Cable (50/35 Sq.mm. Main & Branch) as per TS & Construction Standard {Main 16-95 Sq. mm Service: 4-35(50) Sq. mm & Neutral 16-95 Sq. mm Service: 2-15 Sg. Mm)}
300
-
-
Earthing set complete with G.I. wire.
48
-
-
G.I. wire. No 10 S.W.G. (90 Kg. per 1.09Km.)
120
-
-
Stay set complete with stay wire and insulator clamp etc.
36
-
-
Bolts & Nuts with washer@7.5kg/km
45
-
-
Sundaries,Pole painting, Danger plate, Number Plate etc.
6
-
-
New LT Line Using 3 phase 4 wire with AB Cable (3X50+1x35)Sq.mm (3.0 Km.)
-
-
-
8.0 m S.T.P.(410:SP-14)
75
-
-
M.S. cross arm (75X40) mm, 500 mm long
75
-
-
Back clamp for cross arm
75
-
-
Dead end fittings for AB Cable with Insulated messenger wire complete with Eye hook as per Construction Standards :
12
-
-
Suspension fittings for AB Cable with Insulated messenger wire complete with Eye hook as per Construction Standards :
63
-
-
AB Cable (3x50+1x35)Sq.mm with insulated messenger/Neutral
3
-
-
Insulation piercing connector suitable for AB Cable (50/35 Sq.mm. Main & Branch) as per TS & Construction Standard {Main 16-95 Sq. mm Service: 4-35(50) Sq. mm & Neutral 16-95 Sq. mm Service: 2-15 Sg. Mm)}
150
-
-
Earthing set complete with G.I. wire.
24
-
-
G.I. wire. No 10 S.W.G. (90 Kg. per 1.09Km.)
60
-
-
Stay set complete with stay wire and insulator clamp etc.
18
-
-
Bolts & Nuts with washer@7.5kg/km
22.5
-
-
Sundaries,Pole painting, Danger plate, Number Plate etc.
3
-
-
New LT Line Using 1 phase 2 wire with AB Cable (1X16+1x25)Sq.mm (5.0 Km.)
-
-
-
8.0 m S.T.P.(410:SP-14)
110
-
-
M.S. cross arm (75X40) mm, 500 mm long
110
-
-
Back clamp for cross arm
110
-
-
Dead end fittings for AB Cable with Insulated messenger wire complete with Eye hook as per Construction Standards :
20
-
-
Suspension fittings for AB Cable with Insulated messenger wire complete with Eye hook as per Construction Standards :
90
-
-
AB Cable (1x35+1x25)Sq.mm with insulated messenger/Neutral
5
-
-
Insulation piercing connector suitable for AB Cable (50/35 Sq.mm. Main & Branch) as per TS & Construction Standard {Main 16-95 Sq. mm Service: 4-35(50) Sq. mm & Neutral 16-95 Sq. mm Service: 2-15 Sg. Mm)}
250
-
-
Earthing set complete with G.I. wire.
30
-
-
G.I. wire. No 10 S.W.G. (90 Kg. per 1.09Km.)
100
-
-
Stay set complete with stay wire and insulator clamp etc.
20
-
-
Bolts & Nuts with washer@7.5kg/km
37.5
-
-
Sundaries,Pole painting, Danger plate, Number Plate etc.
5
-
-
Evaluation Notes How It Works ?