Assam Rifles Tender
View complete overview of Manipur Assam Rifles Tender
Costs
EMD
₹ 1,87,699Document Cost
₹ 1,500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_ARMHA_773903_1Bid Award Id
ViewTender No
VIII.11014/7960/Engr-2023/HQ 10 Sect ARTender Authority
Assam Rifles ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
NIT for Spl repair to existing resdl bldg like roof treatment Clk Ciph bk and non resdl bldg at Shangshak
BOQ for Spl repair to existing resdl bldg like roof treatment Clk Ciph bk and non resdl bldg at Shangshak
BOQ Items
... More
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane 3 mm thick
139.96
-
-
... More
Distempering with 1st quality acrylic washable distemper (ready made) of approved manufacturer and of required shade and colour complete. as per manufacturer's specification One or more coats on old work after preparation of surface
526.62
-
-
... More
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per
manufacturer’s specification Two or more coats on new work
1139.58
-
-
... More
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade One or more coats on old work
289.38
-
-
... More
Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete With 2nd class teak wood beading 62X19 mm
48.3
-
-
... More
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
4.5
-
-
... More
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm).
18
-
-
... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:3:6 (1 Cement : 3 coarse sand (zone-III): 6 graded stone aggregate 40 mm nominal size) for floor
2.7
-
-
... More
Providing and laying damp-proof course PCC 80 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size) for floor
10.8
-
-
... More
Providing & fixing White vitreous china water closet squatting pan (Indian type) along with “S” or “P” trap including dismantling of old WC seat and “S” or “P” trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge. Long pattern W.C Pan of size 580x440 mm
6
-
-
... More
Providing and fixing 100 mm sand cast Iron grating for gully trap / floor trap.
18
-
-
... More
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, Single socketed pipes 110 mm diameter incl all socket T etc complete
24
-
-
... More
-do- but 75 mm diameter incl necessary demolition and making good of PCC floor for WHB, Sink nand bath etc to outer drain
63
-
-
... More
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete
18
-
-
... More
SCHEDULE `A' PART -II (INTERNAL ELECTRIFICATION) RESD BLDG LIKE ROOF TREATMENT WORK, 24 AR SHANGSHAK Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.
120
-
-
... More
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
90
-
-
... More
Supplying and fixing brass batten/ angle holder including connection etc. as required
48
-
-
... More
Supplying and fixing stiff pendent with 300 mm long, 20 mm dia X 1.6 mm thick steel conduit, aluminium cast back plate and brass holder complete, including wiring the down rod with 1.5 sq. Mm FR PVC insulated, copper conductor, single core cable and painting etc. as required
18
-
-
... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 5/6 amps switch
12
-
-
... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 15/16 amp switch
12
-
-
... More
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required
66
-
-
... More
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 32 Amp TP&N.
6
-
-
... More
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
6
-
-
... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
18
-
-
... More
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 10 sq. mm + 1 X 10 sq. mm earth wire.
25
-
-
... More
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
2
-
-
... More
SCHEDULE `A' PART -III (BLDG WORK) REPAIR TO CLK & CIPHEER BK, 24 AR (SHANGSHAK) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:3:6 (1 Cement : 3 coarse sand (zone-III): 6 graded stone aggregate 40 mm nominal size) for plinth protection and drain
6.59
-
-
... More
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and aring and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge
424.66
-
-
... More
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
23.4
-
-
... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 40 mm nominal size) for flooring
23.4
-
-
... More
Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position with necessary stainless steel screws etc Kiln seasoned and chemically treated hollock wood
1.01
-
-
... More
Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete Kiln seasoned and chemically treated hollock wood 50x12 mm
270
-
-
... More
Providing and fixing plain multipurpose cement board(Hight pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete (frame work to be paid seperatately) 6 mm thick Cement bonded wood particle board as per IS:14276
144
-
-
... More
Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required 0.63 mm thick with zinc coating not less than 275 gm/ m²
637.47
-
-
... More
Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete 0.63 mm thick with zinc coating not less than 275 gm/m² in replcement
42
-
-
... More
Distempering with 1st quality acrylic washable distemper (ready made) of approved manufacturer and of required shade and colour complete. as per manufacturer's specification One or more coats on old work after preparation of existing surface.
570.52
-
-
... More
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer’s specification Two or more coats on new work
177.84
-
-
... More
Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete With 2nd class teak wood beading 62X19 mm With 2nd class teak wood beading 62X19 mm
23.33
-
-
... More
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade One or more coats on old work
65.21
-
-
... More
Dismantling doors, windows and clerestory windows (steel or wood)shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead Of area 3 sq. metres and below
12
-
-
... More
Providing wood work in frames of doors, windows, clerestory window sand other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately) Kiln seasoned and chemically treated hollock wood
0.45
-
-
... More
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge 30 mm thick shutters
17.28
-
-
... More
Providing and fixing wire gauge shutters using galvanized M.S. wiregauge of average width of aperture 1.4 mm in both directions with wireof dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws Kiln seasoned and chemically treated hollock wood
18.6
-
-
... More
SCHEDULE `A' PART -IV (INTERNAL ELECTRIFICATION) REPAIR TO CLK & CIPHEER BK, 24 AR (SHANGSHAK) Re-Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.
66
-
-
... More
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
50
-
-
... More
Supplying and fixing brass batten/ angle holder including connection etc. as required
20
-
-
... More
Installation, testing and commissioning of pre-wired,fluorescent fitting / compact fluorescent fitting of all types,complete with all accessories and tube/lamp etc., including supplying and fixing ball and socket arrangement, 2 Nos. Down rods of 20 mm dia X 1.6 mm thick steel conduit upto 30 cm length, painting and wiring the down rods and connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
25
-
-
... More
Supplying and fixing stiff pendent with 300 mm long, 20 mm dia X 1.6 mm thick steel conduit, aluminium cast back plate and brass holder complete, including wiring the down rod with 1.5 sq. Mm FR PVC insulated, copper conductor, single core cable and painting etc. as required
4
-
-
... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 5/6 amps switch& socket
15
-
-
... More
-do- but 15/16 amp
4
-
-
... More
Supplying and fixing 8 way, Double door, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator),
2
-
-
... More
Supplying and fixing 3 pin, 5 amp ceiling rose on the junction box/ wooden block including connection etc as required
25
-
-
... More
Supplying and fixing 12 Module (200mmX150mm) size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
4
-
-
... More
Supplying and fixing 8 Module (125mmX125mm) size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
4
-
-
... More
Supplying and fixing 4 Module (125mmX75mm) size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
11
-
-
... More
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 32 Amp TP&N.
2
-
-
... More
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
2
-
-
... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
12
-
-
... More
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 6 sq. mm + 1 X 6 sq. mm earth wire.
50
-
-
... More
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
2
-
-
... More
SCHEDULE `A' PART -V (BLDG WORK) SPL REPAIR RESD & NON RESD BLDG, 24 AR (SHANGSHAK) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:3:6 (1 Cement : 3 coarse sand (zone-III): 6 graded stone aggregate 40 mm nominal size) for plinth protection and drain
9.43
-
-
... More
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and aring and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge With cement mortar 1:4 (1cement: 4 coarse sand)
506.86
-
-
... More
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
18.99
-
-
... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 40 mm nominal size) including net fininshing of the surface using extra cement for flooring
29.43
-
-
... More
Providing wood work in roof truss, frames of false ceiling, partitions etc. sawn and fixed in position with necessary stainless steel screws etc Kiln seasoned and chemically treated hollock wood
5.41
-
-
... More
Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete Kiln seasoned and chemically treated hollock wood 50x12 mm
326
-
-
... More
Providing and fixing plain multipurpose cement board(Hight pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete (frame work to be paid seperatately) 6 mm thick Cement bonded wood particle board as per IS:14276
188.31
-
-
... More
Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required 0.63 mm thick with zinc coating not less than 275 gm/ m²
637.47
-
-
... More
Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete 0.63 mm thick with zinc coating not less than 275 gm/m² in replcement
42
-
-
... More
Distempering with 1st quality acrylic washable distemper (ready made) of approved manufacturer and of required shade and colour complete. as per manufacturer's specification One or more coats on old work after preparation of surface
746.6
-
-
... More
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer’s specification Two or more coats on new work
921.63
-
-
... More
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade One or more coats on old work
120.03
-
-
... More
Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete With 2nd class teak wood beading 62X19 mm
31.89
-
-
... More
SCHEDULE `A' PART -VI (INTERNAL ELECTRIFICATION) SPL REPAIR RESD & NON RESD BLDG, 24 AR (SHANGSHAK) Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required
132
-
-
... More
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
90
-
-
... More
Supplying and fixing brass batten/ angle holder including connection etc. as required
40
-
-
... More
Installation, testing and commissioning of pre-wired,fluorescent fitting / compact fluorescent fitting of all types,complete with all accessories and tube/lamp etc., including supplying and fixing ball and socket arrangement, 2 Nos. Down rods of 20 mm dia X 1.6 mm thick steel conduit upto 30 cm length, painting and wiring the down rods and connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
50
-
-
... More
Supplying and fixing stiff pendent with 300 mm long, 20 mm dia X 1.6 mm thick steel conduit, aluminium cast back plate and brass holder complete, including wiring the down rod with 1.5 sq. Mm FR PVC insulated, copper conductor, single core cable and painting etc. as required
8
-
-
... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 5/6 amps switch& socket
30
-
-
... More
-do- but 15/16 amp
8
-
-
... More
Supplying and fixing 8 way, Double door, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator),
4
-
-
... More
Supplying and fixing 3 pin, 5 amp ceiling rose on the junction box/ wooden block including connection etc as required
50
-
-
... More
Supplying and fixing12 Module (200mmX150mm) size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
8
-
-
... More
Supplying and fixing 8 Module (125mmX125mm) size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
8
-
-
... More
Supplying and fixing 4 Module (125mmX75mm) size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
22
-
-
... More
Providing and fixing 32 Amp capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. .
4
-
-
... More
Supplying and fixing 63 amps rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. As required.
4
-
-
... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
24
-
-
... More
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 6 sq. mm + 1 X 6 sq. mm earth wire.
50
-
-
... More
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
4
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements