Assam Rifles Tender
View complete overview of Manipur Assam Rifles Tender
Assam Rifles Tender
Electrical Generators And Transformers
Electrical and Electronics
Eprocure
Opening Date1 Oct 2024
Closing Date14 Oct 2024
Tender Amount₹ 4,98,861
Costs
EMD
₹ 9,980Document Cost
₹ 1,000Tender Fee
Refer Documents
Summary
Repair And Maint Of Transformer Distribution Panel Board Incl Replacement Of 33 Ar
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_ARMHA_828712_2Bid Award Id
ViewTender No
VIII.11011/9 Sect/Engr-AMC/NIT/2024-25/22Tender Authority
Assam Rifles ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
NIT for repair and maint of transformer distribution panel board incl replacement of 33 AR
BOQ Items
-ditto as above item No. 01 but (c) Supply of copper copper wire.
20
-
-
-ditto as above item but (d ) Filteration of existing old transformes oil
120
-
-
-ditto as above item No. 01 but (e) Toping up new transformer oil with desirable limit.
20
-
-
-ditto as above item No. 01 but (f) Replacement of old UNSV silica gel in transformer breather .
0.25
-
-
Fixing of LED street lingt in existing electric poles along with perimeter boundry wall including labour charges for shifting ladder and taking down old unsv street lights. (LED street lights will be shall be supply by Dept free of cost).
63
-
-
Repair/ Maint of existing Gang operated device including replacement of wornout UNSV spares and servicing of GOD complete as directed by Engr-in-charge.
2
-
-
Maintenance/ oil servicing of DG set 30 KVA as required for normal functioning both electrical and mechanical following spare parts and repair if required incl replacement of all filters i.e. fuel filter spin on type, air filter, oil filters, change of engine oil as required,radiator servicing, batteries, startup items etc. and make sure that exhaust smoke (Level/colour) as per standard incl cost of testing of all controls & commissioning and 180days warranty of all services for DG set 30 KVA.
Note:- The major spares measure and paid seperately under relative items and minor spares which are not including but required to make functional the DG set shall be included in quoted rate.
1
-
-
(a) Supplying and replacement of fuel filter element set
1
-
-
(b) Supplying and replacement of oil filter spin on type
1
-
-
(c) Supplying and replacement of Engine cooling fan belt
1
-
-
(d) Repair/rewinding of self starter/dynamo incl replacement of dynamo belt
1
-
-
(e) Repairing of control panel box of DG set 30 KVA including replacement of KWH meter starting relay coils and internal copper wiring including connecting contactors, electronic controller and other switch gears complete.
1
-
-
Repair and servicing of desert coolers including replacement of unserviceable water circulation pump vent pipes, repair of fan motors, capacitors etc complete as directed by Engr-in-charge.
8
-
-
Repair and servicing of water coolers any capacity including gas charging, replacement of tap, connecting pipe connections,capacitors etc complete as directed by Engr-in-charge.
6
-
-
Repair of 1x30HP water pump of Bn HQ including rewinding, coupling, bearing, star delta starter and servicing complete. (a) Rewinding of coil.
1
-
-
-ditto as above item No. 17 but (b) Repair/replacement of bush bearing and shaft bearing.
2
-
-
-ditto as above item No. 17 (c ) Replacement of coupling with rubber gasket
1
-
-
-ditto as above item No. 17 (d) Repair of 1xstarter (Star) delta) 30 HP
1
-
-
-ditto as above item No. 17 (e) Service charge
1
-
-
Supply and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1KV grade as required. (a) 2 x16 Sqmm
2
-
-
-ditto as above item No. 22 (b) 2 x25 Sqmm
2
-
-
-ditto as above item No. 22 (b) 4 x25 Sqmm
2
-
-
-ditto as above item No. 22 (d) 3.5 x 35 Sqmm
2
-
-
-ditto as above item No. 22 (e) 3.5 x50 Sqmm
2
-
-
-ditto as above item No. 22 (f) 3.5 x70 Sqmm
1
-
-
-ditto as above item No. 22 (g) 3.5 x95 Sqmm
1
-
-
-ditto as above item No. 22 (h) 3.5 x120 Sqmm
1
-
-
-ditto as above item No. 22 (j) 3.5 x150 Sqmm
1
-
-
Supply and fixing in repairs following capacity of MCCBs and pole on existing panel board with thermomagnetic release and terminal spreaders in existing panel board including drilling holes in cubical panel, making connection etc. as required. 315 A, 35 KA TP MCCB
1
-
-
Supply and fixing in repairs following capacity of MCCBs and pole on existing panel board with thermomagnetic release and terminal spreaders in existing panel board including drilling holes in cubical panel, making connection etc. as required. 200 A, 36 KA 4P MCCB
1
-
-
Supply and fixing in repairs following capacity of MCCBs and pole on existing panel board with thermomagnetic release and terminal spreaders in existing panel board including drilling holes in cubical panel, making connection etc. as required. 100 A, 16 KA TP MCCB
1
-
-
Supply and fixing in repairs following size of cable lugs coneecting to existing panel boards. Aluminium lugs for 10 sqmm cable
50
-
-
Supply and fixing in repairs following size of cable lugs coneecting to existing panel boards. Aluminium lugs for 25 sqmm cable
20
-
-
Supply and fixing in repairs following size of cable lugs coneecting to existing panel boards. Aluminium lugs for 35 sqmm cable
20
-
-
Supply and fixing in repairs following size of cable lugs coneecting to existing panel boards. Aluminium lugs for 50 sqmm cable
20
-
-
Supply and fixing in repairs following size of cable lugs coneecting to existing panel boards. Aluminium lugs for 70 sqmm cable
15
-
-
Supply and fixing in repairs following size of cable lugs coneecting to existing panel boards. Aluminium lugs for 95 sqmm cable
12
-
-
Supply and fixing in repairs following size of cable lugs coneecting to existing panel boards. Aluminium lugs for 120 sqmm cable
12
-
-
Supply and fixing in repairs following size of cable lugs coneecting to existing panel boards. Aluminium lugs for 150 sqmm cable
10
-
-
Erection of steel tubular pole in cement concrete 1:3:6 (1 cement : 3 coarse send : 6 graded stone aggregate 40mm nominal size) foundation including excavation, refilling and secured with holding clamps, bolts,nuts etc. as required.
2
-
-
Supplying and erection of 100mm x 65mm pin insulator complete with GI spindle and nuts, etc. as required.
12
-
-
Supplying and erection of 11 KV disc insulator for 11 KV over head line with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required.
4
-
-
Supplying and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required.
3
-
-
Erection of ACSR conductor of existing diameter including binding etc. as required.
6.5
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements