Assam Rifles Tender
View complete overview of Manipur Assam Rifles Tender
Costs
EMD
₹ 52,500Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_ARMHA_820855_1Tender No
28006/Engr/ES/2024-25/01Tender Authority
Assam Rifles ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
SCHEDULE ‘A’ PART-II (SUPPLY, ERECTION & STRINGING OF LT LINE USING AB CABLE (3X70+1X50))
-
-
-
... More
Supply and fixing of 9 MTR height steel tabular pole S.T.P (410 SP-31) belded with base plate and necessary angle iron for LT line arrangements two coat painting with synthetic enamel paint over a coat of primer
10
-
-
... More
Suspension fitting for AB Cable with bare messenger wire complete with eye hook as per construction standard
10
-
-
... More
Insulation pierching connector for AB Cable Big size (Main 16-95 sqmm service 4-35(50) Sqmm as per TS & Construction standards
40
-
-
... More
Supply and fix LT overhead line on 9 metersteel tabular poles with XLPE insulated AB cable 3 core x70 Sqmm +1 core x35 Sqmm
93.5
-
-
... More
Supply and fix LT overhead line on 9 metersteel tabular poles with XLPE insulated AB cable 3 core x50 Sqmm +1 core x35 Sqmm
400
-
-
... More
Supplying and erection of galvanised stay set for 11 KV over head lines complete with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X7.5 mm thick, thimble, stay clamps, turn buckle ( 20 mm X 600 mm ), 7/ 4.00 mm dia
G.I. stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.
5
-
-
... More
SCHEDULE ‘A’ PART-III (INSTALLATION, TESTING & COMMISSIONING OF 1X100 KVA DISTR SUB-STATION )
-
-
-
... More
Supply installatin testing and commissioning of copper wound trnasformer step down outdoor type complete with standard fittings, HT 11 KV 3 Phase 4 wire with off load tappings on HT side to vary secondary voltage within limit all as per IS:2026 of capacity 100 KVA Installation of transformer on the PCC base plateform 2Mtr x 2Mtrx 60 CM above the GL and 60 Cm below the GL
1
-
-
... More
Supplying of channel iron 100 mm X 50 mm X 6 mm (9.56 kg per metre), pole top bracket/ cross arm for Transformer conductor complete with 50 mm X 6 mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required. 2.86 Long
6
-
-
... More
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) V shape cross arm for two transforme complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required. 2.8 Mtr long
6
-
-
... More
Supplying and erection of a set of cross bracing frame work for 11 KV over head line double pole structure having four members fabricated out of 50 mm X 50 mm X6 mm angle iron to form a rectangle of minimum size 1400 mm width X 2500 mmheight, complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts and nuts etc (as per drawing) and painting with primer and finish paint as required..
1
-
-
... More
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
4
-
-
... More
Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required.
1
-
-
... More
Supply and laying of 240 Sqmm one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
50
-
-
... More
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. Made of G.I. wire of dia 4 mm along with 50mmx50mmx6mm thick angle iron
24
-
-
... More
Indor type LT panel Board made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos aluminium bus bars having current density of 130 A/ sq cm at nominal current rating, necessary joints & expansion joints, fire barrier at each floor, provision of tapping at every metre, continuous earthing with 2 Nos
aluminium strip of suitable size (one on each side) including, G.I. clamping brackets,
angle iron bracket, steel fasteners, connecting to earthing system etc. as required.
Incommer
300 A switch fuse unti -01 No, 300 A Change over switch -01 No, RYB Indicator with sliding fuse unit -01 Set, Voltmeter-01, Ameter -01
Outgoing
100A MCCB TPN -01 No, 63 A MCCB TPN -01 No , 30 A SPN -04 Nos & 16 A SPN-04 Nos
1
-
-
... More
SCHEDULE ‘A’ PART-IV (SUPPLY ERECTION & STRINGING OF 11KV LINE (0.5 KM) WITH ACSR (RABBIT) CONDUCTOR WITH 9M LONG STEEL TABULAR POLE)
-
-
-
... More
Supply of 11 MTR height steel tabular pole S.T.P (410 SP-31) belded with base plate and necessary arrangements two coat painting with synthetic enamel paint over a coat of primer:
4
-
-
... More
Supplying and erection of galvanised stay set for 11 KV over head lines complete with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X7.5 mm thick, thimble, stay clamps, turn buckle ( 20 mm X 600 mm ), 7/ 4.00 mm dia G.I. stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1 cement : 3coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.
4
-
-
... More
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) pole top
bracket/ cross arm for single 11 KV over head line conductor complete with 50 mm X 6mm flat iron clamp, bolts, nuts and washers including drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required.
4
-
-
... More
Erection of pole top/ straight two wire/ V shape two wire, angle iron/ channel iron, cross arm on steel tubular/ rail/ PCC pole for 11 KV as required.
4
-
-
... More
Supplying and erection for 11 KV ACSR Rabbit conductor etc. as required
100
-
-
... More
Supplying and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required
12
-
-
... More
Supplying and erection of 11 KV disc insulator for 11 KV over head lines with
galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required.
6
-
-
... More
Supplying and erection of three piece nonlinear resistortype lightning arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required.
1
-
-
... More
Supply and hanging of overhead line of 11KV on 11 meter steel poles with continuous GI earth wire, , fixing in cross arms with necessary accessories and ACSR Conductor size 3 of 6/1x3.50mm(Rabbit) 400x3 = 1200 +300 mtr extra for HT connection etc 1.5Km@214kg/km= 321.00Kg
0.16
-
-
... More
Erection of steel tubular or rail pole strut in cement concrete 1:3:6 (1 cement : 3coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling and secured with holding clamps, bolts, nuts, etc. as required.
6
-
-
... More
Providing and making steel pole collar with cement concrete (1 cement : 3 coarse sand : 6 stone aggregate 20mm) of specified size and shape including form work, plastering if required, curing etc as required. (volume of pole/ pipe not to be deducted)( 24x0.40x0.40x0.30
0.56
-
-
... More
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
2
-
-
... More
11 KVA Gang Operating device ( Air breaker switch) with insulators, bracing arms and necessary nuts bolts
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements