Assam Rifles Tender
View complete overview of Manipur Assam Rifles Tender
Costs
EMD
₹ 1,03,100Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_ARMHA_479538_1Bid Award Id
ViewTender No
VIII.11011/MPR/Engr/NIT/19/45Tender Authority
Assam Rifles ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
NIT for Provn of 01x PFTS (15x8M) store shelter and 03x08 seated toilet block at Bn HQ 23 Assam Rifles at Tamenglong (Manipur)
BOQ for Provn of 01x PFTS (15x8M) store shelter and 03x08 seated toilet block at Bn HQ 23 Assam Rifles at Tamenglong (Manipur)
BOQ Items
SCHEDULE ‘A’ PART-II (EARTH WORKS) (i) STORE SHELTER
-
-
-
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30cm in depth 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be leveled and neatly dressed.
153
-
-
Removing excavated earth by mechanical/manual transport incl loading, unloading and stacking up to 1 Km.
153
-
-
(ii) TOILET BHLOCK
-
-
-
Earth work in excavation by mechanical/manual means on area incl disposal of excavated earth lead upto 50m and left up to 1.5m disposed to be leveled and neatly dressed all kind of soil.
108
-
-
Removing excavated earth by mechanical/manual transport incl loading, unloading and stacking up to 1 Km.
108
-
-
SCHEDULE ‘A’ PART-III
(RETAINING WALL) (i) STORE SHELTER
-
-
-
Earth work in excavation by mechanicals means (hydraulic excavator)/manual means in foundation trench or drain (not exceeding 1.5m in width or 10 sqm on plan) including dressing of sides and ramming of bottom lift up to 1.5m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50m
26.8
-
-
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering for PCC 1:4:8 ( 40mm nominal size)
8.25
-
-
RRM with hard stone, in foundation and plinth including leveling up with cement concrete 1:6:12 (20mm nominal size) upto plinth level
40.2
-
-
P/L for cement concrete 1:2:4 ( 20mm nominal size) for copping
1.46
-
-
Pointing on stone work with cement mortar 1:3 raised pointing to random rubble masonry.
39
-
-
M/L for 1:3:6 PCC for weep holes
0.38
-
-
M/L for 75mm dia PVC pipe for weep holes
37.25
-
-
M/L for PCC 1:3:6 for drain wk.
3.5
-
-
M/L for form wk for drain wk
21.25
-
-
(ii) TOILET BHLOCK
-
-
-
Earth work in excavation by mechanicals means (hydraulic excavator)/manual means in foundation trench or drain (not exceeding 1.5m in width or 10 sqm on plan ) including dressing of sides and ramming or bottom lift up to 1.5m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50m.
10.72
-
-
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering for PCC 1:4:8 using 40mm graded aggregate.
3.3
-
-
RRM in cement mortar 1:6 with hard stone in foundation and plinth including leveling up with cement concrete 1:6:12 using 20mm graded aggregate.
16.08
-
-
Providing and laying cement concrete 1:2:4 using 20mm graded aggregate.
0.59
-
-
Pointing on stone work with cement mortar 1:3 raised pointing to random rubble masonary.
15.6
-
-
M/L for 1:3:6 PCC for weep holes
0.15
-
-
M/L for 75mm dia PVC pipe for weep holes
14.94
-
-
M/L for PCC 1:3:6 for drain wk.
1.4
-
-
M/L for form wk for drain wk
8.5
-
-
SCHEDULE ‘A’ PART-IV (INTERNAL ELECTRIFICATION)
(i) STORE SHELTER
-
-
-
M/L for point wiring in PVC casing capping for light point/fan point/exhaust fan/ceiling ball with 1.5 Sqm FR PVC insulated copper conduction single core cable in surface/recessed PVC conduct with pain types switch, phenolic laminated sheet suitable size MS box and earthjing the point with 1.5 Sqm FR PVC insulated copper conductor single core cable as required.
23
-
-
M/L for point wiring light/power plug with 2X4 sqmm FR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit along with 1 No 4 sqmm Fr PVC insulated copper conductor single core cables for loop earthing as required
30
-
-
IInstallation, testing and commissioning of pre-wire, fluorescent fitting/compact fluorescent fitting all types, with all accessories and tube etc, directly on ceiling/wall, including connection with 1.5sqmm FR PVC insulated copper conductor single core cable and earthing etc as required.
6
-
-
Installation, testing and commissioning of ceiling ban including wiring the down rods of standing length (up to 30cm) with 1.5sqmm FR PVC insulated, copper conductor, single core cable, etc as required.
6
-
-
Installation, testing and commissioning of resistance type ceiling fan regulator, in existing switch box including connection with 1.5sqmm FR PVC insulated, copper conductor, single core cable, earthing the regulator etc as required.
6
-
-
S/F suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amp modular socket outlet and 5/6 amp modular switch connection etc as required.
2
-
-
S/F suitable size GI box modular plate and cover in front on surface or in recess, including providing and fixing 6pin 15/16 amp modular socket outlet and 15/16 amp modular switch, connection etc as required.
1
-
-
S/F 3 pin, 5 amp ceiling rose on the existing junction box incl connection etc as required.
16
-
-
S/F brass batten/ angle holder including connection etc as required
10
-
-
S/F SP MCB 5 to 32 amp rating, 240 volt, complete with connection testing and commissioning etc as required.
8
-
-
S/F DP MCB isolator 63amp.
1
-
-
S/F 2+8 way single door MCB distribution boards 240V on surface/ recess complete with tinned copper bus bar neutral bus bar earth bar, hinged frond acrylic cover for the MCB knobs detachable gland plate interconnection but without MCB/RCCB/Isolator
1
-
-
Earthing with GI earth plate 600mmx600mmx6mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc with charcoal/coke and salt ad required.
1
-
-
S/L 6 SWG GI wire at 0.50 metre below ground level for conductor earth electrode, including connection/termination with GI thimble etc as required.
15
-
-
Providing and fixing 50mm dia x3.2 mtr GI pipe including (accy) complete with 50mmx50mmx6mm angle iron bracket on wall and 75x90mm shackle insulator with straps for house service connection including painting the angle and flat iron with primer and finish paint etc as reqd.
1
-
-
S/F 1100 volts grade heavy duty aluminum standard conductor 6 sqmm cable PVC insulated served with inner sheathing of PVC tape sheeted in service connection suspended by insulating hangers not more than 1 Mtr apart including 4mm suspension wire, one twin core cable flat or circular.
30
-
-
SCHEDULE ‘A’ PART-V (SEWAGE DISPOSAL
-
-
-
Construction of septic tank 100 users complete all as specified and shown in Drg No. STD/ENGR/09 sheet No.1/1
3
-
-
Construction of Man hole complete all as specified and shown in drg No. STD/ENGR/09 sheet No.1/1
12
-
-
Construction of soak pit complete all as specified and shown in drg No. STD/ENGR/09 sheet No.1/1
3
-
-
SCHEDULE ‘A’ PART-VI (SANITARY FITTINGS )
-
-
-
Providing and fixing white vitreous china water closet squatting pan (Indian type) Orissa pattern WC pan size 580X440mm
24
-
-
Providing and fixing unplasticised PVC moulded sewage line 110mm dia
135
-
-
Providing and fixing PVC tee 110mm dia
12
-
-
Providing and fixing PVC bend 110mm dia
24
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements