Assam Rifles Tender

View complete overview of Manipur Assam Rifles Tender

Assam Rifles Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date28 Sep 2023
Closing Date18 Oct 2023
Tender Amount₹ 64,88,923 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
NIT for Spl Repair to ORs JCOs Md accn and APP treatment for Resdl Buildings at 10 Sect Somsai
BOQ for Spl Repair to ORs JCOs Md accn and APP treatment for Resdl Buildings at 10 Sect Somsai
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and aring and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge With cement mortar 1:4 (1cement: 4 coarse sand). For External and Internal wall.

1867.78

-

-

... More
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)

10.32

-

-

... More
Reinforced cement concrete work in shelves, chajjas, lintels, bands, plain window sills, above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). For Chajja back side and Chajja gable side

6.16

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for chajja (Back side and gable side).

84.72

-

-

... More
Providing laminated veneer lumber conforming to IS:14616 and TAD -15: 2001 (Part B) in factory made frames of doors, windows, clerestory windows and other frames, wrought framed and fixing in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately) Kiln seasoned and chemically treated hollock wood. For Door choukat

1.08

-

-

... More
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) Kiln seasoned and chemically treated hollock wood 35 mm thick shutters

56.4

-

-

... More
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead Of area 3 sq. metres and below

30

-

-

... More
Providing and fixing 2nd class teak wood or equavalent plain lining tongued and grooved, including wooden plugs complete with necessary screws and priming coat on unexposed surface

40.95

-

-

... More
Providing and fixing plain multipurpose cement board(Hight pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete (frame work to be paid seperatately) 6 mm thick Cement bonded wood particle board as per IS:14276

167.03

-

-

... More
Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position with necessary stainless steel screws etc Kiln seasoned and chemically treated hollock wood for ceiling frame

1.44

-

-

... More
Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required 0.63 mm thick with zinc coating not less than 275 gm/ m²

771.94

-

-

... More
Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete 0.63 mm thick with zinc coating not less than 275 gm/m² in replcement

139.2

-

-

... More
Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of G.S. Sheet

771.94

-

-

... More
Distempering with 1st quality acrylic distember (Ready mix) having VOC content less than 50 grams/ litre of approved brand and manufacture to give an even shade One or more coats on old work after Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete for internal surface

2817.72

-

-

... More
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer’s specification Two or more coats on new work on new plastered surface

1077.84

-

-

... More
Finishing walls with water proofing cement paint of required shade New work (Two or more coats applied @ 3.84 kg/10 sqm) for external surface incl preparation of surface

986.39

-

-

... More
Finishing walls with water proofing cement paint of required shade Old work (one or more coats applied @ 2.20 kg/10 sqm) over priming coat of primer applied @ 0.80 litrs/10 sqm complete including cost of Priming coat for external surface incl preparation of surface

113.98

-

-

... More
Distempering with 1st quality acrylic distember (Ready mix) having VOC content less than 50 grams/ litre of approved brand and manufacture to give an even shade One or more coats on old work after preparation of surface

741.92

-

-

... More
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade One or more coats on old work

1070.13

-

-

... More
Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete With 2nd class teak wood beading 62X19 mm

138.4

-

-

... More
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete

645.77

-

-

... More
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests

2

-

-

... More
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required, Kitchen sink with drain board 510x1040 mm bowl depth 250 mm

2

-

-

... More
Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade Old work (one or more coats)

1126.92

-

-

... More
Renewing glass panes, with putty and nails wherever necessary including racking out the old putty Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm)

7.38

-

-

... More
SCHEDULE `A' PART -II (ELECTRICAL WORKS) SPL REPAIR ORs, JCOs ACCN & T-III D/S MARRIED ACCN Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic aminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. Make : Havells/Ancher/Rich/ V-Guard equivelent ISI Mark as per direction of Engr-in-charge. (a) Tube light (main & Gen) - 12 (b) Lt / Bulb (Hoder main & Gen) - 12 (c) Fancy light - 5 (d) Bulk head - 3 (e) Fan - 3 (f) Exhust fan - 1 (g) Call Bell - 1 (h) 5 A socket (on the same bd main) -3.

40

-

-

... More
Wiring for 5 A socket outlet wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire for independent. Make : Havells/Ancher/Rich/ V-Guard equivelent ISI Mark as per direction of Engr-in-charge for gen independent wiring

47.5

-

-

... More
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. Make : Havells/Ancher/Rich/ V-Guard equivelent ISI Mark as per direction of Engr-in-charge

60

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire Make : Havells/Ancher/Rich/ V-Guard equivelent ISI Mark as per direction of Engr-in-charge

15

-

-

... More
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. Make: Havells/Ancher equivelent ISI Mark as per direction of Engr-in-charge

17

-

-

... More
Supplying and fixing brass batten/ angle holder including connection etc. as required. Make: Havells/Ancher equivelent ISI mark as per direction of Engr-in-charge

12

-

-

... More
Supply, Installation ,Testing, Commissioning of LED fency light per fitting, complete with all accessories including connections etc. as required Make : Havells/Bajaj/Standard equivelent ISI mark as per direction of Engr-in-charge

5

-

-

... More
Supply, Installation ,Testing, Commissioning of LED Bulk head light per fitting, complete with all accessories including connections etc. as required Make : Havells/Bajaj/Standard equivelent ISI mark as per direction of Engr-in-charge

3

-

-

... More
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. Make: Havells/Ancher/Bajaj equivelent ISI Mark as per direction of Engr-in-charge

1

-

-

... More
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. Make: Havells/Ancher equivelent ISI Mark as per direction of Engr-in-charge.

3

-

-

... More
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

2

-

-

... More
Supplying and fixing following piano type switch on the existing switch box/ cover including connections etc. as required. 5/6 amps switch Make: Havells/Ancher equivelent ISI Mark as per direction of Engr-in-charge.

3

-

-

... More
Supplying and fixing following piano type switch on the existing switch box/ cover including connections etc. as required. 15/16 A switch Make: Havells/Ancher equivelent ISI Mark as per direction of Engr-in-charge.

4

-

-

... More
Supplying and fixing following piano type socket on the existing switch box/ cover including connections etc. as required. 3 pin 5/6 A socket outlet Make: Havells/Ancher equivelent ISI Mark as per direction of Engr-in-charge.

6

-

-

... More
Supplying and fixing following piano type socket on the existing switch box/ cover including connections etc. as required. 6 pin 15/16 A socket outlet. Make: Havells/ Ancher equivelent ISI Mark as per direction of Engr-in-charge.

4

-

-

... More
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. Bell push. Make: Havells/Ancher equivelent ISI mark as per direction of Engr-in-charge.

6

-

-

... More
Supplying and fixing Single pole 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make: Havells/Ancher/Legrand equivelent ISI mark as per direction of Engr-in-charge.

6

-

-

... More
Supplying and fixing 25 A rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make: Havells/Ancher/Legrand equivelent ISI mark as per direction of Engr-in-charge.

1

-

-

... More
Supplying and fixing 40 A rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make: Havells/Ancher/Legrand equivelent ISI mark as per direction of Engr-in-charge.

1

-

-

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way , Double door

1

-

-

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB Distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way , Double door

1

-

-

... More
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

2

-

-

... More
SCHEDULE `A' PART -I (BUILDING WORKS) SPL REPAIR TO APP TREATMENT FOR RESD BLDG Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 3 mm thick

1665.93

-

-

... More
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size)

1665.93

-

-

... More
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineerin-Charge. With cement mortar 1:4 (1cement: 4 coarse sand)

541.03

-

-

... More
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:2:4 or richer mix (i/c equivalent design mix) for chajja window

0.84

-

-

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.

79.68

-

-

... More
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) for post staging

2.1

-

-

... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). for window and slab for water staging

2.09

-

-

... More
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand)

7.83

-

-

... More
Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of : G.S. Sheet

72.17

-

-

... More
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.

96

-

-

... More
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm)

24.17

-

-

... More
Finishing walls with water proofing cement paint of required shade : Old work (one or more coats applied @ 2.20 kg/10 sqm) over priming coat of primer applied @ 0.80 litrs/10 sqm complete including cost of Priming coat.

784.35

-

-

... More
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. and Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.

1734.49

-

-

... More
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :One or more coats on old work as per direction of Engr-in-charge.

935.51

-

-

... More
Painting (one or more coats) with black Japan paint of approved brand and manufacture to give an even shade.

77.47

-

-

... More
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) Second class teak wood 35 mm thick shutters (finsh thickness)

5.67

-

-

... More
Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete : 250x16 mm

1

-

-

... More
Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : 200x10 mm

2

-

-

... More
Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete :125 mm

2

-

-

... More
SCHEDULE `A' PART -II (ELECTRICAL WORKS) SPL REPAIR TO APP TREATMENT FOR RESD BLDG Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic aminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. Make : Havells/Ancher/Rich/ V-Guard equivelent ISI Mark as per direction of Engr-in-charge. (a) Tube light (main & Gen) - 12 (b) Lt / Bulb (Hoder main & Gen) - 12 (c) Fancy light - 5 (d) Bulk head - 3 (e) Fan - 3 (f) Exhust fan - 1 (g) Call Bell - 1 (h) 5 A socket (on the same bd main) -3.

70

-

-

... More
Wiring for 5 A socket outlet wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire for independent. Make : Havells/Ancher/Rich/ V-Guard equivelent ISI Mark as per direction of Engr-in-charge for main and genr wiring

200

-

-

... More
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. Make : Havells/Ancher/Rich/ V-Guard equivelent ISI Mark as per direction of Engr-in-charge for main and genr wiring

300

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire Make : Havells/Ancher/Rich/ V-Guard equivelent ISI Mark as per direction of Engr-in-charge

50

-

-

... More
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.

6

-

-

... More
Supply & fix exhaust fans AC single phase 230/ 240 V of size 300 mm sweep with louver Make : Havells/Bajaj/Polar equivelent ISI Mark as per direction of Engr-in-charge

8

-

-

... More
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. Make: Havells/Ancher equivelent ISI Mark as per direction of Engr-in-charge

22

-

-

... More
Supplying and fixing brass batten/ angle holder including connection etc. as required. Make: Havells/Ancher equivelent ISI mark as per direction of Engr-in-charge

10

-

-

... More
Installation, testing and commissioning of pre-wired, fluorescent/LED fitting / compact fluorescent/LED fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.

10

-

-

... More
Supply, Installation ,Testing, Commissioning of LED fency/ceiling light per fitting, complete with all accessories including connections etc. as required Make : Havells/Bajaj/Standard equivelent ISI mark as per direction of Engr-in-charge

5

-

-

... More
Supply, Installation ,Testing, Commissioning of LED Bulk head light per fitting, complete with all accessories including connections etc. as required Make : Havells/Bajaj/Standard equivelent ISI mark as per direction of Engr-in-charge

6

-

-

... More
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. Make: Havells/Ancher/Bajaj equivelent ISI Mark as per direction of Engr-in-charge

2

-

-

... More
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

4

-

-

... More
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 5/6 amps switch Make: Havells/Ancher equivelent ISI Mark as per direction of Engr-in-charge.

10

-

-

... More
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 15/16 A switch Make: Havells/Ancher equivelent ISI Mark as per direction of Engr-in-charge.

12

-

-

... More
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 3 pin 5/6 A socket outlet Make: Havells/Ancher equivelent ISI Mark as per direction of Engr-in-charge.

10

-

-

... More
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 6 pin 15/16 A socket outlet. Make: Havells/ Ancher equivelent ISI Mark as per direction of Engr-in-charge.

12

-

-

... More
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. Bell push. Make: Havells/Ancher equivelent ISI mark as per direction of Engr-in-charge.

2

-

-

... More
Supplying and fixing Single pole 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make: Havells/Ancher/Legrand equivelent ISI mark as per direction of Engr-in-charge.

10

-

-

... More
Supplying and fixing 25 A rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make: Havells/Ancher/Legrand equivelent ISI mark as per direction of Engr-in-charge.

5

-

-

... More
Supplying and fixing 40 A rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make: Havells/Ancher/Legrand equivelent ISI mark as per direction of Engr-in-charge.

7

-

-

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way , Double door

2

-

-

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB Distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way , Double door

7

-

-

... More
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

4

-

-

... More
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

6

-

-

... More
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.

15

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.