Assam Rifles Tender
View complete overview of Manipur Assam Rifles Tender
Costs
EMD
₹ 1,74,750Document Cost
₹ 1,500Tender Fee
Refer Documents
Summary
Provn Of Drinking Water Facilities For Khongkhan And Aishi Cob Of 8 Ar Bn
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_ARMHA_826682_1Tender No
17018/8767/WSS/10 Sect/Engr-2024/15Tender Authority
Assam Rifles ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Provn of drinking water facilities for Khongkhan and Aishi COB of 8 AR Bn
BOQ Items
-ditto- but 32 mm dia nominal bore
150
-
-
-ditto- but 25 mm dia nominal bore
200
-
-
-ditto- but 15 mm dia nominal bore
100
-
-
Providing and fixing CI double acting air valve of approved quality with bolts, nuts, rubber insertions etc complete of 50 mm dia.
1
-
-
Providing and fixing gun metal gate valve with CI wheel of approved quality (screwed end) of 50 mm nominal bore.
2
-
-
-ditto- but 40 mm nominal bore
2
-
-
-ditto- but 32 mm nominal bore.
2
-
-
-ditto- but 25 mm nominal bore
4
-
-
Providing and fixing of 2000 Ltr cap Polyethylene water storage tank with cover and suitable locking arrangement.
2
-
-
Providing and fixing of 1000 Ltr cap Polyethylene water storage tank with cover and suitable locking arrangement.
3
-
-
Providing and fixing GI union 50 mm nominal bore in GI pipe including cutting and threading the pipe and making long screws etc complete.
20
-
-
Providing and fixing GI union 40 mm nominal bore in GI pipe including cutting and threading the pipe and making long screws etc complete.
10
-
-
Providing and fixing GI union 32 mm nominal bore in GI pipe including cutting and threading the pipe and making long screws etc complete.
5
-
-
Providing and fixing GI union 25 mm nominal bore in GI pipe including cutting and threading the pipe and making long screws etc complete.
7
-
-
Providing and fixing GI union 15 mm nominal bore in GI pipe including cutting and threading the pipe and making long screws etc complete.
10
-
-
Making connection of GI distribution branch with GI main of 25 to 40 mm nominal sizes by providing and fixing tee incl cutting and threading the pipe etc complete.
3
-
-
Making connection of GI distribution branch with GI main of 50 mm nominal sizes by providing and fixing tee incl cutting and threading the pipe etc complete.
2
-
-
Providing and fixing CP brass bib cock 15 mm nominal bore of approved quality conforming to IS:8931.
20
-
-
Supply, installation, commissioning and testing of Kirloskar make Pumping sets, centrifugal, electric driven complete 5 WHP at rated voltage 415 volts, 50 Hz frequency, three phase AC power supply with suction 65mm dia and delivery 50 mm dia incl PCC 1:3:6 type C2 foundation with MS nut bolts purpose made with hexagonal or square head 20 mm dia and 45 cm long 06 Nos for foundation and DOL starter with all electric connections to the panel with suitable size of PVC insulated multi strand copper conductor 16sqmm. The Electric Motor and pump set should include all the standard and optional accessories as per Kirloskar firm manuals.
2
-
-
Supply and laying cable XLPE insulated screened Meter PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sqmm 4 core incl excavation in trenches, sand cushioning, burnt brick as covering material and testing etc as directed by Engr –in – charge.
700
-
-
Supply, installation, commissioning and testing of factory built assembly of LT panel board floor mounted totally enclosed, cubicle type fabricated from CRCA, MS sheet not less than 1.5 mm thick, dust and water proof with neofrone rubber gasket from operated and shall be suitable for operation on 440 Volts, 3 phase, 4 wire, 50 cycles LT switch gear, complete with 200 Amps capacity copper bus bar, 4 strips of size 20x3 mm thick and 400 mm long epoxy coated in conventional column code with separate sheet metal enclosures incl connection from LT incoming to panel board to outgoing feeder through MCB with suitable size of copper cable and providing thimbles, nut bolts with washers and insulating the same properly all as specified and comprising the following:- (a) S/F of phase indicator lamps 01 set RYB (b) S/F Voltmeter 0 to 500 volts complet with selector switch for incoming -01 (c) S/F Ammmeter 0 to 63 Amps incl CTs of suitable ratio and selector switch for Outgoing-01 (d) S/F MCCB triple pole and neutral 415 Volts , 63 AMP Capacity - 01 No (e) S/F chnage over switch 415 volts in steel meteal encloser , 4 pole of capacity 63 AMP - 01 Nos
1
-
-
SCHEDULE `A' PART -II (RCC WATER TANK 42,000 LTR CAPACITY WITH COVER SLAB) COB KHONGKHAN
-
-
-
Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan incl disposal of excavated earth upto 50 m and lift upto 1.5 m, disposed soil to be leveled and neatly dressed in all kinds of soil.
18.92
-
-
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), incl dressing of sides and ramming of bottoms, lift upto 1.5 m, incl getting out the the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m, of all kinds of soil
33.11
-
-
Providing and laying in position 1:4:8 (1 Cement: 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) cement concrete of specified grade excluding the cost of centering and shuttering- all work upto plinth level.
2.84
-
-
Providing and laying in position1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level
13.26
-
-
M/L Centering and shuttering incl strutting, propping etc and removal of form for walls (any thickness) incl attached pilasters, butteresses, plinth and string courses etc
102.43
-
-
Providing and fixing GI pipes complete with GI fittings and clamps, i/c cutting and making good the walls of 50mm dia nominal bore.
2
-
-
S/F Gun metal gate valve with CI wheel of approved quality (screwed end) of 50 mm nominal bore.
2
-
-
M/L Steel reinforcement for RCC work incl straightening, cutting, bending, placing in position and binding all complete upto plinth level of Thermo Mechanical Treated bars
3211.23
-
-
M/L Reinforced cement concrete work of 1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate 20 mm nominal size) for covering slab, incl attached pilasters, buttresses, plinth and string course, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centering, shuttering, finishing and reinforcement for RCC cover slab
2.58
-
-
Centering and shuttering incl strutting, propping etc and removal of form for suspended floors, roofs, landings, balconies and access platform. for RCC cover slab
13.32
-
-
Steel reinforcement for RCC work incl straightening, cutting, bending, placing in position and binding all complete above plinth level of Thermo Mechanical Treated bars. for RCC cover slab
155.94
-
-
SCHEDULE `A' PART -I (WATER SUPPLY PUMPING DISTRIBUTION PIPE LINE) COB AISHI
-
-
-
Providing and fixing GI pipes complete with GI fittings including trenching and refilling etc of 50 mm dia nominal bore
30
-
-
-ditto- but 40 mm dia nominal bore
600
-
-
-ditto- but 32 mm dia nominal bore
150
-
-
-ditto- but 25 mm dia nominal bore
200
-
-
-ditto- but 15 mm dia nominal bore
100
-
-
Providing and fixing CI double acting air valve of approved quality with bolts, nuts, rubber insertions etc complete of 50 mm dia.
1
-
-
Providing and fixing gun metal gate valve with CI wheel of approved quality (screwed end) of 50 mm nominal bore.
2
-
-
-ditto- but 40 mm nominal bore
2
-
-
-ditto- but 32 mm nominal bore.
2
-
-
-ditto- but 25 mm nominal bore
4
-
-
Providing and fixing of 2000 Ltr cap Polyethylene water storage tank with cover and suitable locking arrangement.
2
-
-
Providing and fixing of 1000 Ltr cap Polyethylene water storage tank with cover and suitable locking arrangement.
3
-
-
Providing and fixing gun metal non-return valve of approved quality (screwed end) of 50 mm nominal bore (Horizontal).
2
-
-
Providing and fixing gun metal non-return valve of approved quality (screwed end) of 40 mm nominal bore (Horizontal).
1
-
-
Providing and fixing GI union 50 mm nominal bore in GI pipe including cutting and threading the pipe and making long screws etc complete.
2
-
-
Providing and fixing GI union 40 mm nominal bore in GI pipe including cutting and threading the pipe and making long screws etc complete.
20
-
-
Providing and fixing GI union 32 mm nominal bore in GI pipe including cutting and threading the pipe and making long screws etc complete.
5
-
-
Providing and fixing GI union 25 mm nominal bore in GI pipe including cutting and threading the pipe and making long screws etc complete.
7
-
-
Providing and fixing GI union 15 mm nominal bore in GI pipe including cutting and threading the pipe and making long screws etc complete.
10
-
-
Making connection of GI distribution branch with GI main of 25 to 40 mm nominal sizes by providing and fixing tee incl cutting and threading the pipe etc complete.
3
-
-
Making connection of GI distribution branch with GI main of 50 mm nominal sizes by providing and fixing tee incl cutting and threading the pipe etc complete.
2
-
-
Providing and fixing CP brass bib cock 15 mm nominal bore of approved quality conforming to IS:8931.
20
-
-
Supply, installation, commissioning and testing of Kirloskar make Pumping sets, centrifugal, electric driven complete 15 WHP at rated voltage 415 volts, 50 Hz frequency, three phase AC power supply with suction 65mm dia and delivery 50 mm dia incl PCC 1:3:6 type C2 foundation with MS nut bolts purpose made with hexagonal or square head 20 mm dia and 45 cm long 06 Nos for foundation and DOL starter with all electric connections to the panel with suitable size of PVC insulated multi strand copper conductor 16sqmm. The Electric Motor and pump set should include all the standard and optional accessories as per Kirloskar firm manuals.
2
-
-
Providing and fixing GI pipes complete with GI fittings including trenching and refilling etc of 65 mm dia nominal bore.
20
-
-
Providing and fixing GI union 65 mm nominal bore in GI pipe including cutting and threading the pipe and making long screws etc complete.
2
-
-
Supply, installation, commissioning and testing of factory built assembly of LT panel board floor mounted totally enclosed, cubicle type fabricated from CRCA, MS sheet not less than 1.5 mm thick, dust and water proof with neofrone rubber gasket from operated and shall be suitable for operation on 440 Volts, 3 phase, 4 wire, 50 cycles LT switch gear, complete with 200 Amps capacity copper bus bar, 4 strips of size 20x3 mm thick and 400 mm long epoxy coated in conventional column code with separate sheet metal enclosures incl connection from LT incoming to panel board to outgoing feeder through MCB with suitable size of copper cable and providing thimbles, nut bolts with washers and insulating the same properly all as specified and comprising the following:- (a) S/F of phase indicator lamps 01 set RYB (b) S/F Voltmeter 0 to 500 volts complet with selector switch for incoming -01 (c) S/F Ammmeter 0 to 63 Amps incl CTs of suitable ratio and selector switch for Outgoing-01 (d) S/F MCCB triple pole and neutral 415 Volts , 63 AMP Capacity - 01 No (e) S/F chnage over switch 415 volts in steel meteal encloser , 4 pole of capacity 63 AMP - 01 Nos
1
-
-
Supply and laying cable XLPE insulated screened Meter PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sqmm 4 core incl excavation in trenches, sand cushioning, burnt brick as covering material and testing etc as directed by Engr –in – charge.
500
-
-
Supply, installation, commissioning and testing of silent Diesel Engine driven generating set 415 volts, 3 phase 4 wire, engine as per IS:10001/10002 and Alternator as per IS: 13364 complete with foundation (as per OEM design), control panel with necessary meter and sound proof canopy as per CPCB norms of capacity 30 KVA
1
-
-
SCHEDULE `A' PART -II (INTAKE WATER TANK (2.00x1.50x2.0M) 3000 LTRS CAPACITY) COB AISHI
-
-
-
Earth work insurface excavarion not exceeding 30 cm indepth but exceeding 1.5 m inwidth as wellas 10 sqm on plan incl disposal of excavated soil to be leveled and neately dressed inall kinds of soil
4.14
-
-
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), incl dressing of sides and ramming of bottoms, lift upto 1.5 m, incl getting out the the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m, of all kinds of soil
1.24
-
-
Providing and laying in position cement concrete of 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) excluding the cost of centering and shuttering – All work up to plinth level.
0.45
-
-
Providing and laying in position cement concrete of 1:2:4 excluding the cost of cenetering and shittering - All work up to plinth level
0.23
-
-
M/L of Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS:2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement: 6 coarse sand) with FPS brick.
1.66
-
-
M/L 12 mm cement plaster or mix 1:4 (1 cement: 4 fine sand).
14.4
-
-
Finishing wall with water proofing cement paint of required sahde of rwo or mopre coat applied @ 3.84 kg/ sqm
14.4
-
-
SCHEDULE `A' PART -III (RCC WATER WEIR 8 M LONG) COB AISHI
-
-
-
Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan incl disposal of excavated earth upto 50 m and lift upto 1.5 m, disposed soil to be leveled and neatly dressed in all kinds of soil.
9.6
-
-
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), incl dressing of sides and ramming of bottoms, lift upto 1.5 m, incl getting out the the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m, of all kinds of soil
11.52
-
-
Providing and laying in position 1:4:8 (1 Cement: 4 coarse sand: 8 graded stone aggregate 40 mm nominal size) cement concrete of specified grade excluding the cost of centering and shuttering- all work upto plinth level.
0.96
-
-
Providing and laying in position1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level
5.85
-
-
M/L for cement plaster (in fine sand) of mix 1:4 (1 cement : 4 sand)
39.2
-
-
Providing and fixing GI pipes complete with GI fittings and clamps, i/c cutting and making good the walls of 50 mm dia nominal bore
10
-
-
Providing and fixing gun metal gate valve with CI wheel of approved quality (screwed end) of 50 mm nominal bore.
2
-
-
M/L Steel reinforcement for RCC work incl straightening, cutting, bending, placing in position and binding all complete upto plinth level of Thermo Mechanical Treated bars
648.28
-
-
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
9.12
-
-
SCHEDULE `A' PART -IV (RCC WATER TANK 42,000 LTR CAPACITY WITH COVER SLAB) COB AISHI
-
-
-
Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan incl disposal of excavated earth upto 50 m and lift upto 1.5 m, disposed soil to be leveled and neatly dressed in all kinds of soil.
18.92
-
-
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), incl dressing of sides and ramming of bottoms, lift upto 1.5 m, incl getting out the the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m, of all kinds of soil
33.11
-
-
Providing and laying in position 1:4:8 (1 Cement: 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) cement concrete of specified grade excluding the cost of centering and shuttering- all work upto plinth level.
2.84
-
-
Providing and laying in position1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level
13.26
-
-
M/L Centering and shuttering incl strutting, propping etc and removal of form for walls (any thickness) incl attached pilasters, butteresses, plinth and string courses etc
102.43
-
-
M/L for cement plaster (in fine sand) of mix 1:4 (1 cement : 4 fine sand)
115.75
-
-
Providing and fixing GI pipes complete with GI fittings and clamps, i/c cutting and making good the walls of 50mm dia nominal bore.
2
-
-
S/F Gun metal gate valve with CI wheel of approved quality (screwed end) of 50 mm nominal bore.
2
-
-
M/L Steel reinforcement for RCC work incl straightening, cutting, bending, placing in position and binding all complete upto plinth level of Thermo Mechanical Treated bars
3211.23
-
-
M/L Reinforced cement concrete work of 1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate 20 mm nominal size) for covering slab, incl attached pilasters, buttresses, plinth and string course, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centering, shuttering, finishing and reinforcement for RCC cover slab
2.58
-
-
Centering and shuttering incl strutting, propping etc and removal of form for suspended floors, roofs, landings, balconies and access platform. for RCC cover slab
13.32
-
-
Steel reinforcement for RCC work incl straightening, cutting, bending, placing in position and binding all complete above plinth level of Thermo Mechanical Treated bars. for RCC cover slab
155.94
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements