Airports Authority Of India Tender
View complete overview of Manipur AAI Tender
Airports Authority Of India - AAI Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date16 Dec 2024
Closing Date6 Jan 2025
Tender Amount₹ 21,67,789
Costs
EMD
₹ 43,356Document Cost
₹ 1,180Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_AAI_217677_1Tender No
AAI/IMP/ENGG(E)/VRV-AC/2024-25Tender Authority
Airports Authority Of India ViewPurchaser Address
-Website
http://etenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Hi Side - Outdoor Units
-
-
-
... More
Supply, installation, testing and commisioning of variable refrigerant flow / variable refrigerant volume modular type outdoor unit complete with hermetically sealed DC inverter scroll type compressor with BLDC motor Heat exchanger / condenser coil, microproccessor controller, low noise condenser fan, auto check function for connection error, auto address setting and minimum capacity as mentioned below incuding foundation as per OEM complete with all accessories etc. All outdoor unit should have cooling COP not less than 3.80 & 6.0 at 100% & 50% load condition respectively for colling as per AHRI standards and conditions capable of operation upto 50 Degree ambient. The outdoor aluminium fins should be with corrosive resistance coating apart from hydrophobic coating. The configuration of outdoor unit may be higher capacity or equal capacity as per site condition.
-
-
-
... More
a) 10 HP (cooling only)
3
-
-
... More
Item No. 1.2: Low Side - Indoor Units - (High wall Units)
-
-
-
... More
Supply of Indoor Units for variable refrigerant flow airconditioning system suitable for 220 ± 10% volt, 50 Hz, 1 phase AC supply equipped with washable filter, BLDC motor including corded remote and y - branches, drain pan, drain water lift-up mechanism, insulation, pipe connections, fresh air intake etc. complete with PVC insulated FRLS copper conductor electric wire upto 1.5 metre length for electrically connecting the IDU with minimum capacity as given below.
-
-
-
... More
a) 10 HP cooling capacity with 3200 CFM airflow
3
-
-
... More
Item No. 1.3: Supply, Installation, testing and commissioning of necessary fittings, Y-joints and headers etc.
4
-
-
... More
Item No. 1.4: Supply, installation, testing and commissioning of wired remote controls.
3
-
-
... More
Item No. 2: COPPER PIPING
-
-
-
... More
Item No. 2.1: Refrigerant Piping
-
-
-
... More
Supply & Installation of interconnecting following sizes of one end expanded refrigerant copper pipe work of following outer diameter, insulated with 19/13 mm thick closed cell electrometric EPDM/nitrile rubber tubular insulation between each set of indoor & outdoor units with outer mechanical protection of alluminum cladding for all exposed pipes as per specification. All piping inside the room shall be properly fixed/supported with suitable size of clamp / M.S. hanger and all external piping shall run in M.S. painted cable tray (Price Extra) etc. as reqd.
-
-
-
... More
Item No. 2.1.2: 34.9 mm dia with 19 mm thick EPDM/nitrile rubber insulation.
70
-
-
... More
Item No. 2.1.3: 28.6 mm dia with 19mm thick EPDM/nitrile rubber insulation.
12
-
-
... More
Item No. 2.1.4: 22.2 mm dia with 19mm thick EPDM/nitrile rubber insulation.
40
-
-
... More
Item No. 2.1.5: 19.1 mm dia with 13 mm thick EPDM/ nitrile rubber insulation.
70
-
-
... More
Item No. 2.1.6: 12.7 mm dia with 13 mm thick EPDM/ nitrile rubber insulation.
12
-
-
... More
Item No. 2.1.7: 9.5 mm dia with 13mm thick EPDM/nitrile rubber insulation.
40
-
-
... More
Item No. 3: Drain Piping
-
-
-
... More
Item No. 3.1: Providing & fixing of PVC Pipe complete with fittings of following sizes.
-
-
-
... More
a) 25 mm dia with 6 mm thick insulation
70
-
-
... More
b) 32 mm dia with 6 mm thick insulation
70
-
-
... More
c) 40 mm dia with 6 mm thick insulation
60
-
-
... More
Item No. 3.2: Gas filling of R410
30
-
-
... More
Item No. 4: Control & Transmission Wiring
-
-
-
... More
Item No. 4.1: Providing & fixing control cum transmission wiring of 2 core x 1.5 sqmm copper in MS conduits between indoor and out door unit and between indoor units and their remote sensor/controller.
100
-
-
... More
Item No. 5: Cables
-
-
-
... More
Item No. 5.1: Supplying, laying, testing and commissioning of XLPE insulated Copper conductor armored cables, 4C x 10 Sq.mm of 1.1 KV grade of following sizes directly on wall/structural frame/ cable trays or racks using approved type of clamps, With / Without End terminations with Double Compression type glands on both ends, double earthing with GI strip/wire of suitable size and hardware as per specifications including termination of cables to feeders complete in all respect.
200
-
-
... More
Item No. 5.2: Supply and laying of 3C x 2.5 Sq.mm PVC insulated and PVC sheathed Flexible copper conducotr of 1.1 KV grade for indoor Units in MS conduit.
80
-
-
... More
Item No. 6: Supply, installation, testing and balancing of square/circular return air diffusers of powder coated extruded aluminium construction without volume control dampers.
5
-
-
... More
Item No. 7: Removal and modification of existing false ceiling and ducts made of 2' x 2' for aestheticaly covering as per site conditions.
25
-
-
... More
Item No. 8: Supply of 25 mm thick double skin plenum Box made of 36 Kg/M3 density puff sandwiched in 0.5 mm PCGI suitable for indoor unit CFM.
3
-
-
... More
Item No. 9: Supply and installation of flexible canvass connection for indoor unit.
3
-
-
... More
Item No. 10: Supply, installation, testing and commissioning of Jet Nozzles suitable for indoor unit CFM inclusive of GI butterfly damper 18 SWG frame with 20 SWG blade, 150 mm depth.
9
-
-
... More
Item No. 11: Providing, fabrication and fixing of 50 mm x 50 mm x 5 mm MS angle support for positioning ODU and support for copper pipping i/c grouting, welding, fixing clamps, bolts, nuts, and washers and painting with primer and finish paint etc. complete as required.
100
-
-
... More
Item No. 12: DISMANTLING
-
-
-
... More
Item No. 12.1: Dismantling of existing 22 TR IDU & ODU ductable AC including Cable, Copper pipe, Iron frame, other accessories and handing over to AAI store along with material list. The agency must submit the work plan for dismalting of the AC duct. The work shall be carried out in phase Manner as per the available length i/c temporary covering with green shade net during the dismantling work and also the false ceiling as per area where work is not completed.
1
-
-
... More
Item No. 12.2: Dismantling of existing AC Duct after removing and refixing the same to the orignial design and finishing including handing over dismantled duct to AAI store.
3
-
-
... More
Item No. 13: Supply and installation of 300 mm x 62.5 mm x 2 mm perforated Hot dip Galvanished Cable trays with perforation not more than 17.5% in covenient sections, joined with connectors fixed on wall/Floor/Surface/Ceiling with necessary fixing accessories for running refrigerant piping and cable along with control wiring etc., complete as required.
100
-
-
... More
Item No. 14: Supply and installation of top loaded Normal, Hot and Cold water dispenser suitable for use with 20 litre AR for opeerating on 1-Phase, 50 Hz, 230 VAC power.
5
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%