Airports Authority Of India Tender

View complete overview of Manipur AAI Tender

Airports Authority Of India - AAI Tender

Goods
Electrical Goods and Equipments
Electrical and Electronics
GEM
Opening Date14 Dec 2023
Closing Date12 Feb 2024
Tender Amount₹ 1,84,59,071 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of 200W, 20A by 6.6A, 5 KV grade 50 Hz series type isolating transformers. , Supply of 200 W, 20A by 6.6A, 5 KV grade 50 Hz series type isolating transformers, encapsulated in polyester resin, finally moulded with neoprene type rubber with primary and secondary connections meeting ICAO requirement as per IS and IEC etc. complete as required. (Secondary lead should be suitable for plug in connection to the secondary lead of the fittings offered).

8

-

-

... More
Supply of 6 sqmm 5 KV grade plug and receptacle of type I class B connector. , Supply of 6 sqmm 5 KV grade plug and receptacle of type I class B connector, suitable for field attachment with 5 KV grade PVC insulated PVC sheathed single core copper conductor cable as required and confirming to the relevant IS meeting ICAO requirement.

76

-

-

... More
Supply of 2 x 6 sqmm 5 KV grade plug and receptacle. , Supply of 2 x 6 sqmm 5 KV grade plug and receptacle of type I class B connector, suitable for field attachment with 5 KV grade PVC insulated PVC sheathed single core copper conductor cable as required and confirming to the relevant IS meeting ICAO requirement.

8

-

-

... More
Supply of Transformer housing box. , Supply of transformer housing box of size 330 x 330 x 400 mm (depth), all sides and bottom are made out of 8 mm thick MS sheet and top cover made out of 10 mm thick MS sheet having clear hole of 216 mm dia with 6 nos. M10 size threaded holes on the top for fixing of fixture base plate, 01 No. 25 mm dia drain hole in bottom and suitable holes to enable entry of 40 or 50 mm dia for GI pipe entry for incoming and outgoing cables, two nos. cadmium plated earthing bolts with nuts and washer etc., including painting with one coat of red oxide paint and two coats of black paint finish as required and as per drawing enclosed.

15

-

-

... More
Supply of 1 x 6 Sq.mm, 5 KV grade airfield lighting cable. , Supply of single core 6 Sq.mm, 5 KV grade, stranded annealed plane copper conductor PVC insulated and PVC sheathed, unarmored underground, anti-rodent anti termite treated airfield lighting cable, confirming to IS 1554 Part II with up to date amendments as required.

3838

-

-

... More
Supply of 2 x 6 Sq.mm, 5 KV grade airfield lighting cable. , Supply of 2 x 6 Sq.mm, 5 KV grade, stranded annealed plane copper conductor PVC insulated and PVC sheathed, unarmored underground, anti-rodent anti termite treated airfield lighting cable, confirming to IS 1554 Part II with up to date amendments as required.

2145

-

-

... More
Supply of 63 mm Outer Dia HDPE pipe , Supply of 63mm Dia(outer)HDPE pipe,PE63,PN6,ISI marked along with all accessories complete for laying of 2 Core 6sq.mm AFL feeder cable by HDD method from CCR to nearest MIRL fitting.

1090

-

-

... More
Laying of 5 KV grade power cable in existing pipe. , Laying of one number PVC insulated and PVC sheathed or XLPE power cable of 5 KV grade of following size in the existing RCC or HUME or METAL or DWC HDPE pipe as required. (For 1x 6/2 x 6 /1 x 16 sq. mm).

5983

-

-

... More
Making Field connections by crimping plug and receptable type essna connectors. , Making Field connections by crimping plug and receptable type essna connectors for 6, 16 sq.mm core copper conductor cable of 5KV grade including applying corrosion inhibiting compound(crimping paste), PVC tapping and water seal tapping etc., complete as required.

96

-

-

... More
ITC of elevated type MIRL on the existing transformer housing boxes. , Installation, testing and commissioning of elevated type MIRL on the existing transformer housing boxes including, installation of transformers, lens, filters, lamps and other accessories alignment, levelling and making secondary lead connections to transformer and fittings earth connections etc. complete as required.

76

-

-

... More
ITC of Inset type bi-directional high intensity runway edge light fixture. , Installation, testing and commissioning of Inset type bi-directional high intensity runway edge light fixture on runway surface including PCC or RCC Core cutting installation of housing box, lens, filters, lamps and other accessories alignment, levelling and making secondary lead connections to transformer and fittings earth connections etc. complete as required.

8

-

-

... More
Installation of MS Transformer housing box. , Installation of MS Transformer housing box indicated in Item No. 07 and 08 in runway shoulder including providing 75 mm thick cement concrete 1 isto 2 isto 4 all around and bottom of the transformer housing box with required slope to match with the bitumen surface and plastering of exposed surface with cement mortar 1 isto 3 of thickness 12 mm over the concrete surface including painting top of MS box after installation etc. as required.

15

-

-

... More
Demolishing cement concrete or bituminous road or paverblock roads by manually or mechanical means. , Demolishing cement concrete or bituminous road or paverblock roads by manually or mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-charge.

10

-

-

... More
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia. , Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal or coke and salt as required.

12

-

-

... More
Supplying and laying 6 SWG G.I. wire. , Supplying and laying 6 SWG G.I. wire at 0.75 metre below ground level along with cable and connect to conductor earth electrode, including connection, termination with GI thimble etc. as required.

5983

-

-

... More
Providing and laying in position cement concrete 1 isto 2 isto 4 in foundation or road crossing etc. , Providing and laying in position cement concrete 1 isto 2 isto 4 (1cement isto 2 coarse sand isto 4 graded stone aggregate 20 mm nominal size) in foundation or road crossing etc., including form work etc as required.

5

-

-

... More
Supply and making field connection. , Supply and making field connection of 2.5 Sq.mm, 8 mtr. long, copper conductor, two pin secondary lead of 5 KV grade assembly suitable for runway or taxiway or approach or inset light fittings etc., complete as required.

8

-

-

... More
DSITC of guidance sign boards. , Design, Supply, Installation, Testing and Commissioning of guidance sign boards having various sizes (As per ICAO standard) with central split type opening for easy maintenance made of reinforced 2 mm thick anodized aluminum profile with suitable support. The rear panel shall be made of 1.2 mm. Signage sheet shall be 4 mm thick, long life imported poly carbonate non-specular surface with letters and symbols made out from 3M film pasted from inside with required colouring for mandatory, informatory guidance sign. The boards shall be internally illuminated with suitable numbers of LED tube lamps and all other accessories including converter, ballast to be operated on 2.8A to 6.6Amps, AC constant current series system including isolating transformer. Board shall have secondary leads protected with MS flexible pipe with its adaptor including nut bolt, frangible mounting legs, flange, all civil works like excavation, C.C. foundation. Board shall have necessary water proof protection and shall be equivalent to ICAO latest amendment complete in all respects as required.

48

-

-

... More
Dismantling of existing elevated type airfield lighting system. , Dismantling of existing elevated type airfield lighting system, including C.I. Box, light fitting, Isolating transformers and cable terminals from C.I. Box, loading, shifting, unloading, and handing over to AAI warehouse and demolishing of projected PCC or RCC existing foundation and leveling the same with PCC and disposal of material as per direction of Engineer-in-charge.

8

-

-

... More
Maintaining the existing runway lighting system. , Maintaining the existing runway lighting system on the existing shoulder (on temporary basis) by providing 600 mm x 60 mm x 100 mm Cement Pre-cast Slab having 100 mm dia (OD) in the centre and 6 nos. x M-10 size SS nut grouted for receiving the Base Plate of R-Way edge light fittings including providing 2 parallel holes accross the thickness of the slab, necessary interconnection with the 5 kv grade AFL, 2.5 sq.mm secondary lead cable of R-Way edge light, ISolation X-mer, making field connection etc. complete to the satisfaction of the AAI Official while civil works are underway.

8

-

-

... More
Supply of 3.5 C x 240 Sq.mm, XLPE insulated and PVC sheathed armoured aluminium conductor power cable of 1.1 KV grade. , Supply of 3.5 C x 240 Sq.mm, XLPE insulated and PVC sheathed armoured aluminium conductor power cable of 1.1 KV grade conforming to IS 7098 (Part-1) with upto date ammendments etc., complete as required.

100

-

-

... More
Supply of 3.5 C x 185 Sq.mm, XLPE insulated and PVC sheathed armoured aluminium conductor power cable of 1.1 KV grade. , Supply of 3.5 C x 185 Sq.mm, XLPE insulated and PVC sheathed armoured aluminium conductor power cable of 1.1 KV grade conforming to Standard IS 16205(Part 24) - 2018 with upto date ammendments etc., complete as required.

100

-

-

... More
Supply of 3.5 C x 120 Sq.mm, XLPE insulated and PVC sheathed armoured aluminium conductor power cable of 1.1 KV grade. , Supply of 3.5 C x 120 Sq.mm, XLPE insulated and PVC sheathed armoured aluminium conductor power cable of 1.1 KV grade conforming to Standard IS 16205 (Part 24) - 2018 with upto date ammendments etc., complete as required.

100

-

-

... More
Supplying and laying of 120 mm dia i.e OD-120 mm and ID-103 mm nominal HDPE pipe. , Supplying and laying of 120 mm dia i.e OD-120 mm and ID-103 mm nominal HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to Standard IS 16205 (Part 24) - 2018 complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.

200

-

-

... More
Laying in pipe Above 95 sq.mm and upto 185 sq.mm. , Laying of one number PVC insulated and PVC sheathed, XLPE power cable of 1.1 KV grade of following size in the existing RCC or HUME or METAL or DWC or HDPE pipe as required. Above 95 sq. mm and upto 185 sq.mm.

200

-

-

... More
Laying in pipe. Above 185 sq.mm and upto 400 sq.mm. , Laying of one number PVC insulated and PVC sheathed, XLPE power cable of 1.1 KV grade of following size in the existing RCC or HUME or METAL or DWC or HDPE pipe as required. Above 185 sq. mm and upto 400 sq.mm.

100

-

-

... More
Supplying and making straight through joint - 3.5 x 120 sq.mm. , Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed, XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5 x 120 sq.mm

2

-

-

... More
Supplying and making straight through joint - 3.5 x 185 sq.mm. , Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed, XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5 x 185 sq.mm.

2

-

-

... More
Supplying and making straight through joint - 3.5 x 240 sq.mm. , Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed, XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5 x 240 sq.mm.

2

-

-

... More
Laying, Jointing and commissioning of HPDE pipe of 63 mm dia. , Laying, Jointing and commissioning of HPDE pipe of 63 mm dia, PE 63, PN 6 by trenchless method by carrying out Horizontal Directional Drilling (HDD) along or across various fexible or rigid pavement like Runway or Taxiway and service Road or Drain etc. at various site or location as per the drawing approved by AAI including survey, information collection regarding underground utilities, sensing of utilities by sensing equipment, pit making, pilot drilling, pre-reaming, pulling the supplied duct or cable of various size as per the design invert level and Providing baricades and necessary warning signal lights, closing of pit with excavated earth, restoration of Paved Surfaces or Utilities etc. as required.

1090

-

-

... More
SITC of Microprocessor Assisted, Indoor Air Cooled Type, Constant Current Regulator. , Supply, Installation, Testing and Commisioning of Microprocessor Assisted, Indoor Air Cooled Type, Constant Current Regulator of Thyristor Control Electronics Type to Operate on 230V, 415 AC Supply, 50 Hz c.s. input System with Output Power of 4 KW at 6.6 Amp with 5 Steps Variation of current Output (6, 5.2, 3.4, 2.8 Amp) Suitable for Local and Remote Control Operation with 48 V Control, Supply Complete with Output Ammeter of 0 - 10 Amps Range, Overcurrent, Over Voltage, Earth Fault Protection and Earth Leakage Meter, Positive Back Indications Equipment, Hour Run Counter. LCD Display Complete as Required and as Per AAI Specification.

4

-

-

... More
SITC of Airfield Lighting Control and Monitoring System. , SITC of ALCMS with controlling positive back indication and Monitoring type L890 BB for 17 CCR and 25 fixed circuit including minor working in CCRs and other circuit etc., to the requirement of the FAA advisory Circular No. AC 50 by 5345-56B current edition and additional circuit or mechanism or interfaces for power supply equipment, and landing-H etc., to make them compatible with the ALCMS, data and power cabling, earthing etc., including all hardware and software, license and other items as required for successful operation of the system in line with the scope of three works, details of equipment , equipment specification, performance criteria etc., as specific in SCC and technical specification for Imphal Airport.

1

-

-

... More
Supply and laying of Fibre Optic Cable through Existing HDPE pipe. , Supply and laying of single mode 4 core Armoured Fibre Optic Cable, through Existing HDPE pipe Laid on surface or duct including clamps, RJ 45 termination etc., as required.

950

-

-

... More
Supply, Laying, Jointing and commissioning of HPDE pipe of 40 mm dia. , Supply, Laying, Jointing and commissioning of HPDE pipe of 40 mm dia, PE 63, PN 63 by trenchless method by carrying out Horizontal Directional Drilling (HDD) along or across various fexible or rigid pavement like Runway or Taxiway and service Road or Drain etc. at various site or location as per the drawing approved by AAI including survey, information collection regarding underground utilities, sensing of utilities by sensing equipment, pit making, pilot drilling, pre-reaming, pulling the supplied duct or cable of various size as per the design invert level and Providing baricades and necessary warning signal lights, closing of pit with excavated earth, restoration of Paved Surfaces or Utilities etc. as required.

950

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.