Yashwantrao Chavan Maharashtra Open University Tender
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Yashwantrao Chavan Maharashtra Open University - YCMOU Tender
Electrical and Electronics
Eprocure
Opening Date28 Feb 2024
Closing Date8 Mar 2024
Tender Amount₹ 15,30,593
Costs
EMD
₹ 15,305Document Cost
₹ 590Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_YCMOU_1020109_1Bid Award Id
ViewTender No
UWD/2023-24/10Tender Authority
Yashwantrao Chavan Maharashtra Open University ViewPurchaser Address
-Website
http://https://www.ycmou.ac.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Air Conditioning work for the Renovation of FO Office First Floor, Main Admin Building in campus of YCMOU, Nashik
Air Conditioning work for the Renovation of FO Office First Floor, Main Admin Building in campus of YCMOU, Nashik
BOQ Items
Supply, installation, testing and commissioning of VRF/VRV based Hi-wall type indoor unit (IDU) of nominal cooling capacity 1.3 TR - 1.7 TR ( 421 to 586 cfm) having EER as per BEE standards and specifications with multiple speed evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, expansion device, cordless remote control with necessary controls, with 3-core copper flexible cord of required length and electrical terminal to receive power supply, etc. IDU shall have anti-corrosive coating suitable for coastal area. Unit shall be suitable for indoor wall mounting, having an electronic control console, provided with suitable mounting brackets with any additional refrigerant and oil charge as per the requirement during
installation, connected to the system complete.
3
69390
23130
Supply, installation, testing and commissioning of VRF/VRV based Hi-wall
type indoor unit (IDU) of nominal cooling capacity 1.8TR (594 cfm) to
2.2TR (655 cfm) having EER as per BEE standards and specifications with multiple speed evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, expansion device, cordless remote control with necessary controls, with 3-core copper flexible cord of required length and electrical terminal to receive power supply, etc. IDU shall have anticorrosive coating suitable for coastal area. Unit shall be suitable for indoor wall mounting, having an electronic control console, provided with suitable mounting brackets with any additional refrigerant and oil charge as per the requirement during installation, connected to the system complete.
1
31100
31100
Supply, installation, testing and commissioning of VRF/VRV based ceiling
suspended 4 Way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 2.6TR (918 cfm) to 2.8TR ( 1100 cfm ) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation
1
38657
38657
Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 3.0TR (1100 cfm) to 3.2TR (1165 cfm) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil
charge as per requirement during installation.
3
117783
39261
Supply, installation, testing and commissioning of VRF/VRV based ceiling
suspended 4 Way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 4.1TR (1218 cfm) to 5.0TR (1624 cfm)of suitable cfm having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation
1
57940
57940
Supplying and installation of high pressure grade required size copper connection Y or T- Joints/refnet complete erected on wall/ceiling with supports/raceways, Nitrile rubber insulation, painting etc. with brazing and testing for leakages confirming the normal operation of the VRV/VRF air conditioning system
10
60920
6092
Supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 41.3mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with
OEM standards of VRV/VRF air conditioning system complete.
30
79530
2651
Supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 34.9mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with
OEM standards of VRV/VRF air conditioning system complete.
30
74280
2476
supplying, laying/fixing, testing and commissioning of appropriate nominal
refrigerant copper pipe of 22.2mm dia (OD) for liquid line/suction line supply
and return piping of suitable gauge (hard copper pipe for liquid main line and soft
copper pipe for refrigerant) along with necessary supports, hangers, clamps,
vibration isolators and fittings such as bends, tees, valves, gauges, strainers with
insulation of 19mm thick elastomeric nitrile rubber along with application of
multicoating of VRV/VRF piping for protection against mechanical damages,
fungal growth, flame spread, water permeance and ultraviolet radiation with OEM
standards of VRV/VRF air conditioning system complete.
40
96960
2424
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 19.1 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
40
50440
1261
supplying, laying/fixing, testing and commissioning of appropriate nominal
refrigerant copper pipe of 15.9 mm dia (OD) for liquid line/suction line supply
and return piping of suitable gauge (hard copper pipe for liquid main line and soft
copper pipe for refrigerant) along with necessary supports, hangers, clamps,
vibration isolators and fittings such as bends, tees, valves, gauges, strainers with
insulation of 19mm thick elastomeric nitrile rubber along with application of
multicoating of VRV/VRF piping for protection against mechanical damages,
fungal growth, flame spread, water permeance and ultraviolet radiations with
OEM standards of VRV/VRF air conditioning system complete.
50
55400
1108
supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 12.7 mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiations with
OEM standards of VRV/VRF air conditioning system complete.
60
49200
820
supplying, laying/fixing, testing and commissioning of appropriate nominal
refrigerant copper pipe of 9.5 mm dia (OD) for liquid line/suction line supply
and return piping of suitable gauge (hard copper pipe for liquid main line and soft
copper pipe for refrigerant) along with necessary supports, hangers, clamps,
vibration isolators and fittings such as bends, tees, valves, gauges, strainers with
insulation of 19mm thick elastomeric nitrile rubber along with application of
multicoating of VRV/VRF piping for protection against mechanical damages,
fungal growth, flame spread, water permeance and ultraviolet radiations with
OEM standards of VRV/VRF air conditioning system complete.
60
41340
689
supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 6.4mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiations with
OEM standards of VRV/VRF air conditioning system complete.
60
31980
533
Supplying Installing Testing & Commissioning of The OEM commendation shall be followed for shielded control cable 3.0 Core x 1.5 Sqmm to be used. And the cost mentioned in this section should be quoted accordingly.
300
55500
185
Lifting Shifting Erection of VRF Outdoor Unit From Ground Level to ODU Place as per site requirement With the Help of Telescopic Crane
1
25000
25000
Supply & Commissioning of The Refrigerant Shall Be CFC Free Gas Either R410 or Equivalent as per Piping Length Calculation
20
32000
1600