Western Railway Tender

... More
The WR has issued a formal invitation for competitive bids for the Western Railway project, for Supply, Installation, Rehabilitation, Testing & Commissioning Of Signalling Gears At Various Location For Reliability Improvement Including Relay Wiring And Various Outdoor Work For Msdac Replacement And Point Machine Work In Churchgate-virar Section, Mumbai Division, Western Railway in Mumbai, Maharashtra, with an estimated contract value of Rs. 3,97,34,158. The bid opening date for this tender is 09-05-2025 and the last date for bid submission is 30-05-2025. Interested bidders for Western Railway tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Western Railway - WR Tender

Works
Machinery and Tools
Electrical and Electronics
Ireps
Opening Date9 May 2025
Closing Date30 May 2025
Tender Amount₹ 3,97,34,158.25 
Notes
Download

AI Insights

Bid Capacity
... View More
The formula for bid capacity or average annual contractual turnover is V/N or V, whichever is less, where V = Advertised value of the tender in crores of Rupees and N = Number of years prescribed for completion of work for which bids have been invited.
Technical Capacity
... View More
The required prior work experience for the bidder includes completing similar works within the last 7 years, with specific cost requirements. The options are: - Three similar works, each costing not less than 30% of the advertised tender value, which is 11920247.48, - Two similar works, each costing not less than 40% of the advertised tender value, which is 15893663.00, - One similar work, costing not less than 60% of the advertised tender value, which is 23840509.50. The advertised value of the tender is 39734158.25. Similar works include signalling installation, telecom work, or signaling work involving specific systems.

Costs

Summary

Supply, Installation, Rehabilitation, Testing & Commissioning Of Signalling Gears At Various Location For Reliability Improvement Including Relay Wiring And Various Outdoor Work For Msdac Replacement And Point Machine Work In Churchgate-virar Section, Mumbai Division, Western Railway

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Point insulation Complete set as per RDSO Specification IRS: S-40/84 for Switch bracket, Split-Stretcher bar & Gauge tie plates (52 Kg/60Kg as per site requirement).

35

1345

47107.55

... More
Automatic Wire stripping pliers Make- Jokari Super 4 plus , weidmuller / Knipex / Phoenix contact

10

2141

21417

... More
Switch Pedestal with Contact as per drg no 1E-5509-00-0209153-001

-

-

3

... More
Digging of trench 1.2 M deep from rail flange/ road level and, 0.3 Mtr to 0.6 Mtr wide 8 and back filling after placing of DWC/ RCC/GI pipe. (Placing of DWC/RCC/GI pipe covered separately).The ballast disturbed be screened and dressed as required by Engineer-in-charge or his representatives and road tarred immediately. For track crossing, Drg. No. CSTE/3644 Pg.7 of 11 and for Road Crossing, Drg. No. CSTE/3644 Pg. 5 of 11 are to be followed.

200

873

174786

... More
Supply & installation of Industrial Grade Embedded PC as per RDSO TAN no. STS/E/TAN/3007 dated 2.11.12 or latest

3

179360

538080

... More
Colour Light Signal Complete. (ALL MS PARTS HOT DIP GALVANIZED -100 MICRON) This includes:-(1)Post Tubular 140 mm Dia, as per IRS: S-6/81 or Latest & RDSO Drg. No. SA-24625 5 (Advance). (2)CI Base (As per IRS S-10 & RDSO Drg. No. 2011/M with latest assembly). (3) Pinnacle. (4)Ladder Assembly, as per RDSO Drg. No. SA-23156, with Base, Ladder Guards, Platform, Front Maintenance Platform, MS Supporting bracket to Support Ladder. (5)Signal Front Staging Complete Assembly for CLS Unit. (6) Signal back staging as per extent WR Practice. Note: Height of the Post shall be 5.5 Long.

50

21240

1062000

... More
Portable Insulation Fault Location System EDS3090 Portable equipment for insulation 25 fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an equipment for insulation fault location System Voltage AC 20-575V, 42-460Hz and DC 20-504V Response Value 2-10mA

2

691543

1383087.44

... More
Contact Alu-Plus syringe 249 series for Wago terminals, Anti rusting Pest 20 ml

-

-

23

... More
Supply of Relay, Non-AC Immune, plug-in-type style QN1, DC Neutral line, 50V, 8F.8B 27 contacts, front and back contacts metal to carbon with plug board, retaining clip & connectors confirming to BRS:930, IRS:S 34 & IRS:S 23 (as applicable). The interlocking code for this unit shall be ABDEF

100

3127

312700

... More
Cable Knife System 4-70 with automatic blade protection and cable bracket for stripping round cables, Make- Jokari-70000, Weidmuller, Knipex, Phoenix contact

10

4413

44132

... More
Junction route indicator unit 3 ways as per Drg. No. RDSO SA 23403 is suitable for LED Signal Lighting Units & as IRS: S-66/84 amndt-1 or latest. (Supply of LED Units is not covered in this item).

2

28167

56335.1

... More
Fixing of Q series relay base plate/metal to metal relay mini group and major group base plate, laying, bunching, lacing, dressing & packeting of 60/40 core PVC indoor cable/flexible wire 4 and termination of 60/40 core cable/flexible wire on tag block/base plate & base plates & soldering. This includes fuse wiring, bus bar looping etc. required for keeping installation ready for circuit wiring work & panel throughing work. The work shall be done as per approved plan, extant practice on WR & the instruction of Rly. Engineer at site.

600

467

280338

... More
Gauge Tie plate nylon insulation as per RDSO Drg No: T- 10372Alt2, T- 10368, T- 10371Alt2, T-15083/88/Alt2 & T-11690/Alt2 and to the spec IRS: S-40/84 with latest amendments as applicable.

35

1503

52628.8

... More
750 VA Off line UPS with battery backup 3 Hours for Failure Analysis System of reputed make as per Engineer in-charge.

3

33329

99987.15

... More
Fixing of ARA Terminals /Screw less connectors and fuse blocks on phenolic laminated sheets and fixing by stainless steel/brass nuts & bolts. This includes provision of two additional holes on the board on either side for cable conductor entry.

100

22

2275

... More
Electric Point machine, Siemens make, non- trailable design, 143mm throw, with IP-67 protection electric point motor as per the RDSO STS/E/PM/MOTOR SPN/VOL-II/14 dt 15.05.20, complete with lock detector, cable termination box and slide for lock and detector , low thrust rotary 1 locking type, AC immunity 160 VAC, along with one set of tools in suitable tool box with every set of ight point machines or less, all as per RDSO specification no-IRS-S-24/2002 with Amdt-1 or latest. Firm's offer for - SIEMENS make Electric point operating machine, non trailable, 143MM throw ( immunity level 160V ) to operate on 110V DC complete with lock and detector slides and cable terminal box. SIEMENS make- as per BSG-antr-9i

35

192534

6738714.5

... More
Torque wrench with reversible ratchet, 10-50 Nm with precision +/- 3% Make:- WERA, Gedore, Stahwille, Snapon

10

21791

217910.6

... More
Crimping pliers PEW12 with Die Set ( Capacity- 16 mm2 /25 mm2 ) Dimension - 250 x 108 x 43 mm Make:- Rennsteig, DMC ,Molex, Amphenol

10

22712

227126.4

... More
Erection of CLS Post with base and signal unit on top or on OFF set Bracket, fixing of front and back staging, ladder and guards with contractor's own brackets and fixing materials. This also includes erection of auxiliary signals like calling on, shunt signal if any... The work shall be done 1 as per instructions of Rly engineer at site. It also includes provision & fixing of maintenance platform as per design given by Engineer -In-Charge at site. It also includes supply of padlock for signal units and cable termination box. X' arms to be provided by the contractor till the signals are introduced. The Item includes cutting of Signal post if required by Site In charge. 2/3/4 aspect signal unit mounted directly on signal post.

50

8338

416937

... More
Fixing of Junction type Route Indication 1-Way/2-Way/3-Wayon the top of the signal post.

12

738

8862

... More
Plug in Type,Tractive Armature, AC Immunized, DC Biased Contactor Relay, Style QBCA1,2HF-4B Contact,24 V DC, Code BCEJK Spec:BRS:943 ; IRS S 34 ; IRS S 23 ;IRSS 60-78

100

7393

739368

... More
Portable ferrule printer for printing cable core functions at locations

-

-

40

... More
Cement concrete work for miscellaneous items in the ratio 1: 3: 6. Item includes excavation, ramming, curing and plastering with cement & sand mixture (aggregate not exceeding 3.8 cm.) (Aggregate cement & sand to be supplied by the contractor).

200

6259

1251800

... More
Supply of Multi lamp route indicator (LED Single/double digit) as per engineer in charge

-

-

6

... More
Soldering Wire resin core 60/40, 18 SWG (PHILCO / KHOSLA MAKE)

-

-

37

... More
Miniature, Plug-in Type, DC Neutral Line Magnetically Latched Relay, Style QL1, 24 V DC, 11F-4B Contact, Code ABDEG Spec: BRS:935A ; IRSS 34 ; IRS S 23

100

7390

739044

... More
Supply of signal no plate as per Drg no CSTE Drg No CSTE/6186.

-

-

10

... More
Single core multi-strand wire 0.5 sq.mm. (16 conductor each dia. 0.2mm), as per IRS 76/89 (Amd3).

20

5548

110970.8

... More
Cable cutter (SWA cable) Capacity (diameter)- 45 mm/380 mm2 with precision blades Make:- KNIPEX , Gedore, Sthwille, Greenlee

5

45548

227740

... More
2-conductor fuse terminal block; with pivoting fuse holder; for 5 x 20 mm miniature metric fuse; with blown fuse indication by LED; 30 - 65 V; for DIN-rail 35 x 15 and 35 x 7.5; 4 mm2; CAGE CLAMP; 4,00 mm2; gray (Without Fuse)

50

205

10266

... More
Supply of End Stopper 10mm/0.0394 in width as per site requirement.

-

-

36

... More
All rounder flexible cable screener Make- Jokari 30900, weidmuller / Knipex / Phoenix contact

10

1362

13629

... More
Termination of outdoor cables, main cables laid in location boxes, Cable termination rack etc. at both ends on ARA terminal or on 8 way terminals or on screw less connectors. Both ends of a cable core terminated shall be counted as one terminal. This includes all associated works of pulling out the cable from underground, peeling off insulation, dressing of cable core supported on sting rod with contractor's own material. The work shall be done as per instructions of Rly engineer at site.

-

-

6

... More
Supply of End plate 2.5mm/0.091 in thick as per site requirement.

-

-

35

... More
Flexible cable (Power wire), multi-strand copper conductors cross section 33 (1x16Sq.mm).101 Conductors each diameter 0.45 +/- 0.01 as per IS 694/2010 with insulation thickness of 1.2mm nominal conductor resistance 1.127 Ohms/Km and test parameters as per IRS(S) 76/89 or latest.

2

136063

272127.1

... More
Multifunctional insulated pliers for cutting, stripping etc Dimension- 200 x 115 x 20 mm Make:- KNIPEX, Gedore, Stahwille, Greenlee

10

6630

66304.2

... More
Junction route indicator unit 2 way as per Drg. No. RDSO SA 23402 is suitable for LED Signal Lighting Units & as IRS: S-66/84 amndt-1 or latest.

4

20990

83963.04

... More
Disconnect Terminal Block, Screw less type, 4-wire front entry (Two in-put & Two out- 34 put) The color will be decided by Engineer - in - Charge. (Preferably In Blue, Red & Grey Colors in the ratio of 1:2:3). as per RDSO Spec. No. RDSO/SPN/189/2004. With latest amendments. Note: Make to be approved by Railway before supply.

8500

58

497505

... More
Excavation and Casting of foundation for Shunt Signal as per Drg. No. CSTE/6090 with 10 Contractor's own materials including Cement and Anchor Bolts of Standard Size. The required scaffolding, Ferma etc. for Casting of foundation will have to be brought by the Contractor at his own cost

5

6139

30698.8

... More
Screwdriver for slotted screws,04x2x60 mm, Size-130x22x22 mm Make :- WERA, Gedore, Stahwille, Snapon (one Lot=10 numbers)

40

4814

192576

... More
Junction route indicator unit 1way as per Drg. No. RDSO SA 23401 suitable for LED Signal Lighting Unit & as IRS: S-66/84 amndt-1or latest. (Supply of LED Unit is not covered in this item).

6

21050

126303.12

... More
Excavation and Casting of foundation for main signal post as per CSTE/3122 (WR) with 2 contractor's own materials including cement and anchor bolts of standard size. The required scaffolding Ferma etc. for Casting of foundation will have to be brought by the contractor at his own cost.

10

12887

128871.8

... More
Position Light Shunt Signal Unit Complete, with offset bracket, hood, Cover etc. as per Drg. No. SA-23840 suitable for LED Signal Lighting Unit. (Supply of LED Unit is not covered in this item).

5

3359

16798.7

... More
Supply of QNNA1, AC immunized relay 24V DC, 4F-4B/6F-2B contacts, along with plug board, retaining clip and connectors. Conforming to BRS: 960, IRS: S60, IRS: S34 & IRS: S23. (No of each configuration will be decided by Engineer In-charge)

50

6039

301980

... More
Excavation of cable trench as per cable route plan, 1 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr wide advised by Engineer-in-charge alongside the track in normal (all type) soil/strata, conforming to distances as per cable route plan and refilling. This work includes clearing of route from bushes 7 etc., covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately before covering by bricks. The work shall be done as per the extant practice on Western Railway and instructions of Railway Engineer at site. In case 1m depth of trench is not achievable due to site conditions, specific approval of JA grade officer will be required for each site where trench depth of 1m is not possible. Without the approval of JA Grade officer, no payment for trenching will be made for trench depth less than 1m.

900

839

755100

... More
Position Light Shunt Signal Unit Complete with Post (made of GI Pipe of 80 mm 42 Diameter Medium Class IS Spec. No. IS: 1239 Pt. 1/1990) Base, Hood, and Cover, etc. as per Drg. No. SA-23840, Signal Number Plate, suitable for LED Signal Lighting Unit. (Supply of LED Unit is not covered in this item). SS TYPE

5

4530

22650.35

... More
Miniature, Plug-in Type, DC Neutral Line AC Immunized Relay, Style QNA1, 24 V DC, 8F-8B/12F-4BContact, Code ABDGH/ABDFH Spec: BRS: 931A; IRS S 34; IRS S 23; IRS S 60-78.

600

5576

3345624

... More
Portable workstation for Data input & configuration with necessary software/ programs / Accessories, simulation and functional testing, diagnostics, and troubleshooting and commissioning 11 of EI system. A suitable table and chair of a reputed make shall be supplied by the contractor. Note: The specification of the portable workstation shall be as per the Technical specification given in Annexure or higher version as approved by Engineer In-Charge. All the required software should be uploaded Licensed CD should be given along with the software. (Name of the reputed firm and technical specification shall be written in tender documents.)

4

147350

589403.48

... More
Automatic Center Punch 60N-130N Make:- Rennsteig, DMC ,Molex, Amphenol

-

-

16

... More
Glass fuse of size 5 x 20 mm, rating 630 mA, 250V(fast blow),make M/s Nandi, M/s Reliance, M/s CEI, M/s Schurter, M/s Little fuses, M/s Siba or similar or better. Make model : cei wagopower.

2000

2

4840

... More
Offset brackets for Shunt Signal, made of tubular steel, outer diameter 89 mm, thickness of pipe 4.5 mm. horizontal length of pipe 324 mm & vertical length of pipe 324 mm with fixing arrangement on Shunt Signal post as per Drawing No SW/354/I

5

4276

21384.6



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.