Tata Memorial Centre Tender
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Tata Memorial Centre Tender
Healthcare and Medicine
Electrical and Electronics
Electrical Works
Eprocure
Opening Date4 Sep 2024
Closing Date7 Oct 2024
Tender Amount₹ 3,43,23,950
Costs
EMD
₹ 6,86,479Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_TMC_824370_1Bid Award Id
ViewTender No
ET-63/Electrical, BMS and EMS System for cGMP Center/2024Tender Authority
Tata Memorial Centre ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
625 KVA DG Set with foundation.
1
-
-
AMF Panel suitable for 625 kVA DIESEL GENERATING SET with battery charger and standard accessories.
1
-
-
MS Class ‘B’ diesel engine exhaust pipe of suitable size (including all fittings, clamps, steel support, required size of foundation) of suitable dia for the engine.
The pipe shall be provided with 12 mm thick ceramic fibre rope and below to be insulated with cloth and glass wool.
30
-
-
Supply & Installation of exhaust pipe thermal insulation and cladding.
30
-
-
Installation of Silencer
1
-
-
Supply & Installation of Silencer thermal insulation and cladding
1
-
-
Supply & Installation of M.S. Supports for Exhaust Pipe & Exhaust Structure
suitable for 1 x 200 mm Exhaust Pipe (Structure Height -25 mtrs) Including Standar Panel & Tray
3
-
-
Supply & Installation of S.S. Bellows 200 mm with matching flanges, gaskets and
fasteners
1
-
-
UPS
-
-
-
Supply, installation, testing & commissioning of 3 Phase Input, 3 Phase Output with Advance 3 level IGBT-PWM based rectifier & Invertor technology with built in isolation transformer AC input voltage:415 V +/- 10% , frequency-50 Hz +/- 5%,output voltage-415V +/- 2% , Output frequency-50Hz +/- 0.5%, True Online double conversion Industrial grade, Input phase sequence correction feature, efficiency up to 95%, high short circuit handling up to 3.5 times, Type of battery - SMF, battery capacity as per backup time specified below, battery charging current shall be calculate for unity power factor, Protection- Electronic over voltage trip, electronic under voltage trip, Single phase prevention, overload, Short Circuit and battery overcharge, Indications: AC On, Inverter on Charger fuse, inverter trip. One number RS485 ports to steady the data with all accessories complete etc.,
-
-
-
160KVA online UPS with built in Isolation Transformer 3-PHASE Input and 3-PHASE Ouoput with 30minutes backup having sealed maintenance free batteries of 48Nos. 12V, 200AH capacity, interconnection cables, end terminations, Battery rack with accessories, etc.
1
-
-
L. T. Panels
-
-
-
Free standing, floor mounted MCC panel made out of 2mm thick CRCA sheet duly powder coated after seven tank process consisting of suitable rating Incomer, Aluminum bus bar supported with DMC/ SMC barriers & color coded with heat shrinkable sleeves, metering and outgoing feeders (as mentioned against each panel):
-
-
-
MCC Panel-1 for AHU 1, 2, 3, 4, 5, 6,7,8 AHU for exhaust-2 Nos, MCC 2, UPS, LDB - 1, PDB-1&2 ( as per enclosed SLD).
1
-
-
UPS Panel for ELDB-1 , EPDB-1 ,EPDB-2, EPDB-3, 2 Nos.250A FP MCCB with enclosure for UPS Input and Output (AS per enclosed SLD).
1
-
-
LV (Power & Control) Cables
-
-
-
1.1kV grade XLPE/PVC insulated aluminum/copper multi-strand conductor steel armoured cables.
-
-
-
3.5C X300mm² AL. Armd. XLPE Insulated cable.
650
-
-
Excavation and Cable layoing and Backfilling as per the ISO Norms
50
-
-
3.5C X240mm² AL. Armd. XLPE Insulated cable.
300
-
-
3.5C X185mm² AL. Armd. XLPE Insulated cable.
100
-
-
3.5C X150mm² AL. Armd. XLPE Insulated cable.
80
-
-
3.5C X95mm² AL. Armd. XLPE Insulated cable.
50
-
-
3.5C X 70mm² AL. Armd. XLPE Insulated cable.
50
-
-
3.5C X 50mm² AL. Armd. XLPE Insulated cable.
70
-
-
3.5 C X 35mm² Al. Armd. XLPE Insulated cable.
100
-
-
3.5C X 25mm² AL. Armd. XLPE Insulated cable.
150
-
-
4 C X 4mm² Cu. Armd. XLPE Insulated cable.
150
-
-
4 C X 2.5mm² Cu. Armd. XLPE Insulated cable.
250
-
-
3 C X 10mm² Cu. Armd. XLPE Insulated cable.
50
-
-
3 C X 6mm² Cu. Armd. XLPE Insulated cable.
150
-
-
3 C X 4mm² Cu. Armd. XLPE Insulated cable.
200
-
-
3 C X 2.5mm² Cu. Armd. XLPE Insulated cable.
170
-
-
1C X35mm² Cu. Unarmd. XLPE Insulated cable.
100
-
-
1C X70mm² Cu. Unarmd. XLPE Insulated cable.
100
-
-
LV Cable End Terminations
-
-
-
Termination of cables with brass double compression glands including cost of crimping lugs / ferrules, solder, cable
sockets, insulation tapes etc.
-
-
-
3.5C X300mm² AL. Armd. XLPE Insulated cable.
24
-
-
3.5C X240mm² AL. Armd. XLPE Insulated cable.
12
-
-
3.5C X150mm² AL. Armd. XLPE Insulated cable.
6
-
-
3.5C X185mm² AL. Armd. XLPE Insulated cable.
6
-
-
3.5C X95mm² AL. Armd. XLPE Insulated cable terminations.
4
-
-
3.5C X 70mm² AL. Armd. XLPE Insulated cable terminations.
4
-
-
3.5C X 50mm² AL. Armd. XLPE Insulated cable terminations.
4
-
-
3.5 C X 35mm² Cu. Armd. XLPE Insulated cable terminations.
4
-
-
3.5C X 25mm² AL. Armd. XLPE Insulated cable terminations.
6
-
-
4 C X 4mm² Cu. Armd. XLPE Insulated cable terminations.
14
-
-
4 C X 2.5mm² Cu. Armd. XLPE Insulated cable terminations.
36
-
-
3 C X 10mm² Cu. Armd. XLPE Insulated cable terminations.
4
-
-
3 C X 6mm² Cu. Armd. XLPE Insulated cable terminations.
6
-
-
3 C X 4mm² Cu. Armd. XLPE Insulated cable terminations.
8
-
-
3 C X 2.5mm² Cu. Armd. XLPE Insulated cable terminations.
8
-
-
1C X35mm² Cu. Unarmd. XLPE Insulated cable terminations.
20
-
-
1C X70mm² Cu. Unarmd. XLPE Insulated cable terminations.
10
-
-
EARTHING
-
-
-
Supply, installation, testing & commissioning of earthing station as per IS standard complete with 600x600x6mm GI Plate electrode, salt, charcoal, 2 nos. 50x6 mm Aluminum strip upto test link, 40 mm dia G.I. watering pipe with funnel, and test link. The chamber size shall be fitted with 450 x 450 mm with heavy duty C.I. Chamber Cover duly painted and marked with pit identification number both inside and outside as per earthing layout Drawing.
8
-
-
50X6mm GI strip.
400
-
-
25X3mm GI strip.
600
-
-
6mm² single core multi strand wire (Green color).
200
-
-
10mm² single core multi strand wire (Green color).
100
-
-
Supply, installation testing of earthing station as per IS standard complete with 600x600x3mm Copper Plate electrode, salt, charcoal, 2 nos. 50x6 mm Copper strip upto test link, 40 mm dia G.I. watering pipe with funnel, and test link. The chamber size shall be fitted with 450 x 450 mm with heavy duty C.I. chamber Cover duly painted and marked with Pit Identification Number both inside and outside as per Earthing Layout Drawing.
4
-
-
50X6mm Copper strip.
150
-
-
25x3mm Copper strip.
350
-
-
Safety Equipments
-
-
-
2000mmX1000mmX12mm corriguated rubber mats, as per standards.
20
-
-
D.C.P. type fire extinguisher for following capacity cartridge type with gun metal cap 150gram CO2 gas cartridge, powder and brackets confirming to IS 2171-19885 and
completed erected with necessary clamps made from 50 x 6mm. MS Flat with Nut & Bolts grouted in wall
complete. 6kg Capacity.
5
-
-
Carbon Dioxide (CO2) Fire Extinguisher user of following capacity with necessary clamps made from 50 x 6mm
M.S. Flat with Nut & Bolts grouted in wall complete. 4.5 kg Capacity.
5
-
-
MCB DISTRIBUTION BOARDS :-
-
-
-
12WAY Three phase power distribution board with vertical double door type (VTPN DB) with 125A TPN MCCB as a incomer & 12 Nos. 32A TP MCB as outgoing circuit. MCB shall be provided with “C” curve.
1
-
-
8WAY Three phase power distribution board with vertical double door type (VTPN DB) with 125A TPN MCCB as a incomer & 8 Nos. 32A TP MCB as outgoing circuit. MCB shall be provided with “C” curve.
1
-
-
3 Phase, 8 WAY Lighting distribution board with horizontal double door type 40A TPN MCB as a incomer, 32A DP ELCB per phase & 18 Nos. 6-10A SP MCB as a outgoing circuit. MCB shall be provided with “C” curve
2
-
-
3 Phase , 12 WAY distribution boards with horizontal double door type (ETPN DB) with per phase Isolation kit , 63A TPN MCB as a incomer, 40 A,300mA, DP ELCB per Phase & 30 Nos. 16A/20A/32A SP MCB in outgoing circuit . (10 Nos, MCB per Phase)(PDB). MCB shall be provided with “C” curve
2
-
-
3 Phase , 8 WAY distribution boards with horizontal double door type (ETPN DB) with per phase Isolation kit , 63A TPN MCB as a incomer, 40 A, 300mA, DP ELCB per Phase & 18 Nos. 16A/20A/32A SP MCB in outgoing circuit .(8 Nos, MCB per Phase)(PDB).MCB shall be provided with “C” curve
2
-
-
Modular & Industrial Type Switch Sockets
-
-
-
Switch Socket Industrial Type
-
-
-
Industrial Pentra type socket & plug with MCB enclosed in enclosure. The scope includes fixing of enclosures ,
supply of all fixing accessories/hardware. MCB and socket shall be wired up upto outgoing terminals etc, complete as required.
-
-
-
Single phase 25 Amp 3 pin socket with straight connected plug with 25 Amp DP MCB.
25
-
-
Single phase 32 Amp 3 pin socket with straight connected plug with 32 Amp DP MCB.
10
-
-
Three phase 32 Amp 5 pin socket with straight connected plug with 32 Amp FP MCB.
20
-
-
Supply and Installation of GI Perforated & Ladder Cable Trays :-
-
-
-
Hot dipped galvanized and minimum thickness of hot dip coating is 70 to 100 microns. Thickness of cable tray sheet steel for 50 mm to 300 mm cable tray 2.0mm Thick minimum height of the perforated cable Tray is 30mm or 50mm. Cable tray shall be in different widths and shall be in standard length 2500mm long and suitable to couple two cable trays with coupler. Support required for fixing the cable trays considered in the Structural steel
-
-
-
50mm(W) X 50 mm(H) X 2mm thinkness perforated cable tray.
300
-
-
100mm(W) X 50 mm(H) X 2mm thinkness perforated cable tray.
100
-
-
150mm(W) X 50 mm(H) X 2mm thinkness perforated cable tray.
60
-
-
300mm(W) X 50 mm(H X 2mm thinkness perforated cable tray.
150
-
-
450mm(W)X 50 mm(H) X 2mm thinkness perforated cable tray.
50
-
-
600mm(W) X 50 mm(H) X 2mm thinkness perforated cable tray.
40
-
-
Structural steel for supports.
2500
-
-
PVC CONDUITS
-
-
-
PVC conduit with Bends, junction boxes, and all necessary accessories and hard ware as following.
-
-
-
25 mm PVC Conduit.
1000
-
-
32 mm PVC Conduit.
100
-
-
50 mm PVC Conduit.
50
-
-
PVC flexible conduit with clamps and all necessary accessories and hard ware as following.
-
-
-
25 mm flexible Conduit.
500
-
-
32 mm flexible Conduit.
100
-
-
50 mm flexible Conduit.
50
-
-
PVC Trunking System
-
-
-
UPVC cable trunking system comprising unplasticised polyvinylchloride rigid material with ignition free. All
necessary accessories as Coupler,Elbow, Tee, Internal Bend, External Bend, End Cap and, Trunking Divider for 105 x 50mm (depth) Trunking and Hard ware.
50
-
-
Ceiling Fan
-
-
-
1200mm sweep Ceiling fan
6
-
-
Electrical consultancy charges alongwith provsion of co-ordinated drawings for complete design for electrical and L.V. drawings with monitoring the work and issuance of final completion certificate for the project.
1
-
-
BMS System
-
-
-
Software
-
-
-
BMS Software: Graphical User interface software based on MS Windows with 1000 points & 1 client license .The system should be accessible from anywhere on LAN or Ethernet . The Communication protocol shall be BACnet Protocols . System should be
scalable in all levels , Eggineer and user level passwords.
1
-
-
BMS Client Station: Intel i7 3rd Generation processor 3Ghz, with 1TB X 2nos hard disk, 16 GB RAM/DVD-RW/keyboard/optical mouse/LAN card/32” LED monitor. Minimum 4 USB ports. With pre-loaded licensed Windows 10 Professional software(Latest version),MS office and Anti virus, Dual 2GB Graphic Cards as per tender specification.
3
-
-
Server PC:- The main servers will be Intel Xeon processor E5-2600, minimum speed of 2.3
GHz with 6 Core, dual Gigabit Ethernet Port, USB port, Video port. The server memory will be 16 GB DDR4 RAM with 21 inch monitor
1
-
-
Laser Printer for alarms and reports - A4 size (Black & white)
1
-
-
DDC Panels
-
-
-
IP based DDC controllers with in-built real time clock, 32 bit micro-processor CPU,
memory, enclosed in MS powder coated enclosure as per IO summary
-
-
-
DDC-1&2 (AHU-1,AEU-1 & AHU-6,AEU-6) with IO Points of AI - 26, DI - 24, AO - 10 &
DO - 08
4
-
-
DDC-3&4 (AHU-2,3 & AHU-4,5) with IO Points of AI - 22, DI - 14, AO - 08 & DO - 04
4
-
-
DDC-5 for EMS with IO Points of AI -62 , DI - 0, AO - 18 & DO - 0
3
-
-
Gateway module for integrating the third party systems communicating on one of the
Standard Open Protocols such as BACNet and MODBUS, etc with BMS
-
-
-
Chiller intigration, Energy meters, Hot Water Generator
3
-
-
Field Instruments
-
-
-
Testing and Commissioning of following Instruments with required accessories
-
-
-
DP switch across fan to monitor Filter clog status monitoring (Fine Filter)
Range: Max 1000 Pa
10
-
-
Differential Pressure Switch for AHU Run Status range: Max 500 Pa
10
-
-
Duct DP Transmitter across fan
8
-
-
Room Temp, RH & DP Display unit with inbuilt DP and External Temp & RH Transmitter
13
-
-
Static pressure senosr for VFD speed
8
-
-
Duct Mount Temperature & Rh sensor with Temp Accuracy: ±2% & RH Accuracy: ±3%
8
-
-
Damper Actuators
13
-
-
Room Temperature & Rh
13
-
-
Control cables, Cable trays and Conduits with accessories.
-
-
-
6C X 1 Sq mm armoured Copper Shielded Cable
1750
-
-
4C X 1 Sq mm armoured Copper Shielded Cable
1350
-
-
2C X 1 Sq mm armoured Copper Shielded Cable
1225
-
-
Shielded CAT 6 Cable, 4 pair, UTP,24 AWG Cable
2
-
-
GI Perforated Cable Tray 50 X 50 X 2 mm with required MS supports
350
-
-
GI Perforated Cable Tray 100 X 50 X 2 mm with required MS supports
350
-
-
GI Perforated Cable Tray 300 X 50 X 2 mm with required MS supports
300
-
-
25 mm PVC Conduit with its mounting accessories
300
-
-
8 port network switch with Rack
1
-
-
Validation & Documentation
-
-
-
Validation of the BMS system with related qualification documents DQ/IQ/OQ/PQ as per
international norms and client standards.
1
-
-
E.M.S. System
-
-
-
STANDALONE CONTROLLER
-
-
-
Operator PC:- PC with the following minimum specifications: INTEL CORE i7, 3GHz, 4GB RAM, 500GB HDD, 32" LCD monitor, USB Mouse, USB keyboard, DVD / CD writer, modem/IP connectivity, HDMI output, configuration with Windows 10 pro, Office 12 and antivirus(Work station ,operator station ,one stand by as per spec)
1
-
-
EMS Software
1
-
-
Converter for Intigration to EMS systeam
1
-
-
16 port Ethernet switch with Rack
1
-
-
8 port Ethernet switch with Rack
1
-
-
SMPS
2
-
-
Field Instruments
-
-
-
Room DP Transmitter with three row Display unit(T&Rh and DP)
18
-
-
Room Temperature & Rh Transmitter
18
-
-
Control cables, Cable trays and Conduits with accessories.
-
-
-
6C X 1 Sq mm armoured Copper Shielded Cable
600
-
-
3C X 1.5 Sq mm armoured Copper Cable
300
-
-
Shielded CAT 6 Cable, 4 pair, UTP,24 AWG Cable
915
-
-
GI Perforated Cable Tray 50 X 50 X 2 mm with required MS supports
100
-
-
GI Perforated Cable Tray 100 X 50 X 2 mm with required MS supports
350
-
-
GI Perforated Cable Tray 300 X 50 X 2 mm with required MS supports
50
-
-
25 mm PVC Conduit with its mounting accessories
200
-
-