Tata Memorial Centre Tender
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Tata Memorial Centre Tender
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date16 Apr 2024
Closing Date10 Jun 2024
Tender Amount₹ 60,30,000
Costs
EMD
₹ 1,20,600Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_TMC_804023_1Bid Award Id
ViewTender No
ET-162/Domestic Water Supply/2023Tender Authority
Tata Memorial Centre ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Datasheet for Pressure Relief Valves
Datasheet for Pressure Reducing Valves
Datasheet for Steel Y Type Strainer
BOQ Items
150 mm SS 316 Bourdon type Glycerin Filled Normal Pressure gauge (150mm dial) with gauge cock - range 0-16 kg/sq.cm(g), gauges should be fitted on both suction and discharge headers . Gauges in Suction shall be compound type, Make: Wika, H - Guru, Waree
1
-
-
Piping in the pump house (aboveground) : SITC of SS 304 External Polished & Buffed Pipe Conforming to (ASTM A312) , Heavy Class, Upto 150 NB Schedule 10. For 100 NB , 80 NB, 25 NB shall be Schedule 40 including fitting, elbows, tees, reducers, painting, support, nuts, bolts, washers, gaskets etc as required with Argon Gas Welding and Welding Electrodes as per tender requirements, Al Pipes shall be despatched with End caps Make: Tata/Jindal/Roopam Steel
-
-
-
300mm dia.
15
-
-
200mm dia.
10
-
-
150mm dia.
50
-
-
100mm dia.
10
-
-
80 mm dia.
20
-
-
50 mm dia.
10
-
-
25mm dia.
10
-
-
SITC of Cast Steel (may include SS 304 component) Gate Valves with flanged ends with matching companion flages as per API 600, Class 150 , PN 20 rating OS & Y Type Raising Stem type Gate Valve , Maximum Working Pressure 300 psi, Hydrostatic pressure 600psi for Potable Water Service, Refer Datasheet for detailed specifications
-
-
-
200mm dia.
1
-
-
150mm dia.
2
-
-
100mm dia.
2
-
-
80mm dia.
2
-
-
50mm dia.
2
-
-
SITC of Cast Steel (may include SS 304 component) Check Valve as per BS 1868 with flanged ends with matching companion flanges, Class 150 , PN 20 rating , Maximum Working Pressure 300 psi, Hydrostatic pressure 30 bar for Potable Water Service, Refer Datasheet for detailed specifications
-
-
-
150 mm dia
1
-
-
80 mm dia
2
-
-
SITC of Cast Steel (may include SS 304 component) Y Type strainer with flanged ends with matching companion flanges, Class 150 , PN 20 rating , Maximum Working Pressure 300 psi, Hydrostatic pressure 30 bar for Potable Water Service, Shall have SS 304 Mesh of 1.5 mm hloles and mesh shall be removable and cleanable. Refer Datasheet for detailed specifications
-
-
-
150 mm dia
1
-
-
100 mm dia
1
-
-
80 mm dia
1
-
-
SS 304, Ball Typ Non return valve with matching flanges , PN 20 rating, fittings, nuts, bolts, washers etc., Make : Valves - Hawa / L& T Audco / Kirloskar / Azbil/ Flowserve
-
-
-
150 mm dia.
1
-
-
SITC of 150 mm dia Electro magnetic type flow meter with flange connections for the test header and meter range shall be 50% - 200% of the nominal flow and direct digital display, 4- 20 mA & HART output, direct reading type as per datasheet
1
-
-
SS 304 Ball valves as per IS:9890 - screwed type
-
-
-
25mm dia.
3
-
-
SITC of Power Distribution Board free standing type MCC Panel as per IS/IEC 61349, Copper Busbars, Copper rods of 16mm for panel earthing, Caution signages and Electrical Safey built within panel, Siemens Grey Colour of MS 1.6mm CRCA thickness with 7 tank process of manufacture , colour powder coated to Siemens Grey with 100mm Base frame, minimum dimensions of 2100X 2000 X 800 ( HX W X D ) mm with base frame of 100mm with gland plate MCCB/Breaker, Load Manager, Overload relays, Contactor, Star Delta Starter etc in Type 2 coordination for individual motor loads ( all motors are IE3 Motors, so all compnents shall be accordingly selected) as shown in distribution board drawing ( for Controllers & Curret Meter, Pumps of Transfer Pumps ( 30 HP 1W + 1S ) & Hydropneumatic Pumps ( 30 HP 2W ) & Jockey Pump ( 1No. 15 HP) . It may happen that Transfer Pumps, HPN Pumps & Jockey Pump can run simultaneously at one time. Lighting Load 63A, Emergency Back Up System ligting lod 32A , Space Heater, Inside lighting on Door Open and Auto Supply Cut off switch, Auto Transfer Switch 400A with two incomers of main & standby power wired directly from two individual feeders , 400 A Incomer MCCB, 200 A MCCB for Transfer Pumps and 200A for Hydropneumatic System, Pump House Lighting & Exhaust Fan MPCB 63 A. spare 3 phase 63 A Connection for connecting 3 phase loads as per enclosed drawing and in line with NBC, CIDCO, ACTREC Electrical & Safety Standards. All cable glands SS 304, IP 65 and Double compression type. Panel shall have removable lifting eyebolts. Two Place grounding on panel Panel board should have access below the panel of at least 1000mm and hence panel should be rested on required supports or RCC with access platform in RCC
1
-
-
The Control Panel Manufacturer shall have CPRI , CE , Approval, Company Shall be ISO 9001 certified. The Panel shall be of the following .Consider BMS contacts around 30 Nos for PLC system. Manufacturer shall have CPRI , CE , Approval, COmpany Shall be ISO 9001 certified. The Panel shall be of the following Make Only. : L & T, Siemens, Schneider, Elecmec
-
-
-
SITC of Armoured PVC/XLPE Insulated FRLS Copper Cable, 1100V, Tinned Copper, Shielded ( for Instrumentation ) , Twisted ( for communication) , Wherever in building in 25mm GI Conduit for LV System, LT Cables on GI Cable Trays or Excavated in Soft soil , Road crossing, Remaking of road, Make : Polycab/Metaplast/ Lapp/Belden/ Supercab/Ramco
-
-
-
3C X 2.5 sq mm
50
-
-
3C X 4 Sq mm
50
-
-
3C X 10 sq mm
50
-
-
3C X 16 Sq mm
40
-
-
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer and two coats of paint all complete. The work is including scaffolding, HILTI bolting etc.
1
-
-
Electrical Hoist Fitted on Hook with Chain Pulley System for Maintenance of Pumps & motors on Pump House Ceiling
1
-
-
SITC of GI Perorated Cable Trays 50 X 50mm X 16 SWG with coupler plates, all mounting accessories for wall , column mounting
30
-
-
SITC of GI Perorated Cable Trays 300 X 50mm X 14 SWG with coupler plates all mounting accessories for wall , column mounting
20
-
-
SITC of Copper strip of size 25mmX3mm, copper strip shall be ETP grade only.
30
-
-