South Central Railway Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

South Central Railway - SCR Tender

Works
Electrical and Electronics
Electrical Works
Ireps
Opening Date10 Sep 2024
Closing Date1 Oct 2024
Tender Amount₹ 1,26,85,444.25 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
2(c)(i)Reinforced Concrete for foundation, plinth and cable trenches

-

-

11449.22

... More
2(c)(ii)Cable trench covers

-

-

16420.62

... More
2(d)(i)Reinforcement brick work

-

-

15982.74

... More
2(d)(ii)Plastering of brick work

-

-

1784.85

... More
1(b)Preparation of design and drawings for switching station including Modifications / Alterations to drawings for existing switching station.

-

-

28203.51

... More
1(c)Preparation of station working rules diagram and working instructions

-

-

24618.47

... More
3(b)Erection of fabrication steel work such as TTC, portals, sps etc.

-

-

16712.87

... More
3(c)Erection of fabricated small Part steel

-

-

66851.48

... More
3(e)Supply and Erection of Guy rod assembly.

-

-

15730.27

... More
3(g)Supply of steel reinforcement for RCC work.

-

-

49635.75

... More
7[c]Supply and erection of earth wire.

-

-

798.07

... More
7(d)Manual erection of all Aluminum 25 kV Feeder / Return conductor (spider)

-

-

9366.49

... More
7(e)Erection of copper cross feeder wires (37/2.25 mm HDBC)

-

-

299.12

... More
8(b)(iii)Supply without Insulator and erection of material for termination of all aluminum 25 kV Feeder/ Return conductor (single SPIDER)

-

-

8120.9

... More
8(b)(ix)Supply (other than Insulators) and erection of materials for termination of copper cross feeder with gantries.

-

-

20526.23

... More
11(a)(i)Supply without Insulator and erection of 25 kV solid core cut-in insulator.

-

-

5444.76

... More
11(a)(ii)Supply without Insulator and erection of 25 kV solid core suspension insulator.

-

-

45764.6

... More
11(b)Supply without Insulator and erection of 25 kV post Insulators.

-

-

7730.75

... More
13(a)Supply without insulator and erection of 25 kV Single Pole Isolator with-out earth contact assembly.

-

-

114050.96

... More
13(c)Supply without insulator and erection of 25 kV Double Pole Isolator

-

-

290705.1

... More
13(e)Extra on item 13(a), (b) or (c) for an inter-locking device.

-

-

9385.28

... More
15(a)Supply of material excluding copper wire and erection of all types of copper jumpers

-

-

15519.3

... More
15(b)Supply and erection of Aluminium jumper

-

-

5340.72

... More
15(d)Supply of materials and erection of Large copper jumper wire 160 Sq.mm between Aluminium bus and cross feeders

-

-

5128.31

... More
15(e)Supply of materials and erection of Large copper jumper wire 160 Sq.mm between cross feeders and OHE

-

-

8453.25

... More
16(a)Supply and Erection of structure bonds

-

-

7239.45

... More
16(aa)Drilling of Holes on Rails

-

-

1300.5

... More
16(b)Supply and erection of longitudinal bond.

-

-

2051.9

... More
16(c)Supply and erection of transverse and special bonds

-

-

3381.3

... More
17(a)Supply and erection of earth electrode

-

-

5990.97

... More
17(c)Supply and erection of earth bus

-

-

13113.38

... More
17(d)Supply and erection of Copper strips for equipment earthing

-

-

6979.35

... More
17(e)Supply and erection of 8 SWG G.I wire for earthing

-

-

809.2

... More
18(a)Erection of 25 KV Interruptor SF-6/Vaccum

-

-

10156.91

... More
18(d)Extra for erection of interlocking mechanism for item 18(a), 18(b) and 18(c )

-

-

375.7

... More
19(a)(i) Erection of 25 KV PT (Type-I)

-

-

2232.53

... More
20(a)Erection of 42 KV lighting Arrestors

-

-

1936.3

... More
21Supply and erection of Terminal boards in control cubicle

-

-

14912.4

... More
22(a)Supply and erection of an Iron clad 110V DC Fuse box

-

-

531.76

... More
22(b) Supply and erection of 220 V AC Fuse box

-

-

755.74

... More
22(c)Supply and erection of 240 V L.T Distribution board in the control room for 10 KVA L.T. Supply transformer.

-

-

58627.99

... More
22(d) Supply and erection of 110 V DC Distribution board.

-

-

28254.09

... More
23(a)Erection of lead acid battery (110V, 40-Ah)

-

-

5339.28

... More
24(a)Erection of battery charger for 110 V, 40 Ah battery

-

-

734.06

... More
25(a)Supply and installation of cable for control and indication

-

-

5707.75

... More
25(b)Supply and installation of cable for heater supply

-

-

1986.88

... More
25(c)Supply and installation of cable for catenary indication

-

-

2456.5

... More
25(d)Supply and installation of cable for LT power supply

-

-

5527.13

... More
25(e)Supply and installation of cable for 110V DC power supply

-

-

2564.88

... More
25(f)(i)(ii)Laying of 70/25 sq.mm cable

-

-

2023

... More
25(g)(i)Excavation of cable trench (in ordinary soil)of size 30cm wide and 90cm deep including half cut RCC/hume pipes,sand etc., & making original arrangements.

-

-

10974.78

... More
25(g)(ii)Excavation of cable trench (under the track)of size 110cm deep and 30cm wide and supply and laying of RCC/hume pipe and making original arrangements.

-

-

8670

... More
25(g)Supply and fixing of cable markers.

-

-

3901.5

... More
25(h) (i)Supply and Erection of 7 core ,2.5 sq.mm copper cable

-

-

5707.75

... More
25(l)Supply and Erection of 2 core ,4 sq.mm copper cable

-

-

3359.63

... More
25(i)Supply and installation of 2 Core 2.5 sq.mm

-

-

2456.5

... More
26(a)(i)Supply and erection of Aluminum bus bar 36mm x 28mm

-

-

9190.2

... More
26(a)(ii)Supply and erection of copper Bus-Bar 18 mm

-

-

22108.5

... More
26(b)(i)Supply and erection of aluminum bus terminal (6480)

-

-

46904.7

... More
26(b)(iv)Supply and erection of aluminum bus bar terminal connector 36/20 mm(6530)

-

-

56181.6

... More
26 (c) (v)--Supply and erection of Aluminum bus bar 50mm x 39mm.

-

-

16848.7

... More
27(a)Oil filtration, erection, testing and commissioning of 25 KV/240 volts, 5/10/25/50 kVA LT supply transformer

-

-

4382.69

... More
27(c)Erection of LT control board for AT location

-

-

2272.99

... More
28Supply and erection of 25 KV Drop out fuse switch for all oil/dry type AT's of all capacities

-

-

8782.71

... More
30(a)(i)Supply and erection of fencing panel at switching stations

-

-

131350.5

... More
30(a)(ii)Supply and erection of fencing upright

-

-

81321.71

... More
30(a)(v)Supply and erection of gates.

-

-

2431.94

... More
30(b)(i)Supply and erection of anti climbing device at switching stations

-

-

14811.25

... More
30(b)(iii)Supply and erection of anti climbing device etc : L.T. stations

-

-

1478.24

... More
31(a)Transfer of equipment from one mast or support to other.

-

-

3748.33

... More
31(b)Provision of an additional bracket assembly / assemblies on a mast or support.

-

-

3323.5

... More
31(l)(i)Retrieval of traction masts, main masts, TTC uprights etc...

-

-

7225

... More
31(t)(ix)Transfer of feeder wire from one mast to another.

-

-

4259.86

... More
32/3(a)Erection of Traction masts and main masts of Switching station and LT supply Transformer station.

-

-

1651.64

... More
32/3(b)Erection of fabrication steel work such as TTC, portals, sps etc.

-

-

4178.22

... More
32/3 ( c)Erection of fabricated small Part steel

-

-

4178.22

... More
32/7(e)Erection of copper cross feeder wires (37/2.25 mm HDBC)

-

-

299.12

... More
32/8(b)(iii)Supply without Insulator and erection of material for termination of all aluminum 25 kV Feeder/ Return conductor (single SPIDER)

-

-

708.05

... More
32/11(a)(i)Supply without Insulator and erection of 25 kV solid core cut-in insulator.

-

-

488.41

... More
32/11(a)(ii)Supply without Insulator and erection of 25 kV solid core suspension insulator.

-

-

293.34

... More
32/11(b)Supply without Insulator and erection of 25 kV post Insulators.

-

-

585.23

... More
32/15(a)Supply of material excluding copper wire and erection of all types of copper jumpers

-

-

1257.15

... More
32/15(b)Supply and erection of Aluminium jumper

-

-

384.37

... More
33/3(a)Extra on erection rate for steel work done manually under item No. 3(a)

-

-

6589.2

... More
33/3(b)Extra on erection rate for steel work done manually under item No.3(b)

-

-

1461.62

... More
36(a)Unloading of all types of steel structures

-

-

910.35

... More
36(b)Loading of all types of Steel structures

-

-

1488.35

... More
37(a)Unloading of all types of Copper & Aluminum conductors

-

-

251.43

... More
37(b)Loading of all types of Copper & Aluminum conductors

-

-

251.43

... More
40Supply and Erection of Number plates on existing masts

-

-

4161.6

... More
41Supply and Erection of various types of caution boards for 25 kV AC traction (PCB, SCB, 25 KV Danger board, power block working limit board etc.,)

-

-

3901.5

... More
42Supply and Erection of shock treatment charts Trilingual English, Hindi and Telugu (laminated)

-

-

254.32

... More
44(a)Supply and erection of name plate for switching stations

-

-

6502.5

... More
44(b)Supply and erection of schematic diagram board and shock treatment charts I switching/ traction sub stations

-

-

3251.25

... More
44(c)Supply and erection of standard first aid box

-

-

903.13

... More
44(d)Supply and erection of fire extinguishers

-

-

19507.5

... More
44(e)Supply and erection of fire buckets with stand

-

-

8670

... More
44(f)Supply and spreading of 20 mm ballast at TSS/SSP/SP yards

-

-

43899.1

... More
3(a)Supply of traction masts and main masts of switching stations, LT supply transformer station and booster transformer station as per latest RDSO drawings and IS Specifications.

-

-

1231573.5

... More
3(b)Supply of fabricated steel work other than masts such as TTC's portal sets (with all components ) etc as per latest RDSO drawings and IS specifiations.

-

-

209279.35

... More
3(c)Supply of Fabricated steel work other than mast, TTC's, portals, such as SPS, special fabricated steel etc

-

-

853185.8

... More
7(c)Supply of 37/2.25 mm hard drawn bare copper cross feeder wire (150 sq.mm) as per latest RDSO specification

-

-

95625.31

... More
15(a)(i)Supply of 160 sq.mm Annealed Stranded copper jumper as per latest RDSO specification

-

-

99650.94

... More
15(a)(ii)Supply of 130 sq.mm Annealed Stranded copper jumper as per latest RDSO specification

-

-

22009

... More
15(a)(iii)Supply of 105 sq.mm Annealed Stranded copper jumper as per latest RDSO specification

-

-

22009

... More
15(a)(iv)Supply of 50 sq.mm Annealed Stranded copper jumper as per latest RDSO specification

-

-

22009

... More
8(bx)(i)Supply of insulators for item no 8(b)(i)(ii)(iii)(v)(vi)(vii)(viii)(ix)

-

-

12643.35

... More
11(ax)(i)Supply of insulators for item no 11(a)(i)(ii)

-

-

202293.61

... More
11(bx)Supply of 25 kV post insulator for item 11(b)

-

-

13150.4

... More
13(ax)Supply of 25 kV post & operating rod insulators for item 13(a)

-

-

33388.56

... More
13(cx)Supply of 25 kV post & operating rod insulators for item 13(c)

-

-

109602.84

... More
28(x)Supply of 25 kV post insulators for item 28

-

-

13152.6

... More
7(a)Supply of All Aluminum 25 kV feeder/Return conductor (single spider) as per latest RDSO specification

-

-

654937.92

... More
Supply and erection of 35 sq.mm. multi strand single core flexible copper cable for extension of 42 kV lightning arrestor connection.

-

-

2314.07

... More
Supply of PG copper clamps between 150 sq.mm. copper cross feeder to 160 sq.mm. copper drop jumper.

-

-

1056.24

... More
Surge arrestor disconnector assembly suitable for 42kV outdoor, track side 25kV surge arrestor of class 3 type as per latest RDSO Spec.

-

-

22081.16

... More
53Transportation of released/New TrD materials

-

-

66640

... More
18(a)(ii)Supply of 25 KV Vaccum Interrupters along with terminal connectors (800 Amps)

-

-

1644876.79

... More
19(a)(i)Supply of 25 KV PT type I with connectors

-

-

114998.98

... More
20(a)Supply of 42 kV LA gapless 10 KA rating with all accessories

-

-

306184.14

... More
23(a)Supply of Lead Acid Battery 110 V, 40 AH capacity

-

-

101067.89

... More
24(a)Supply of battery charger for 40 AH, 110V lead acid battery

-

-

48025.78

... More
27(a)(ii)Supply of 10 KVA, 25 kV/240 volts LT supply Transformers (Oil type) as per latest RDSO Specification No.ETI/PSI/15 (11/92) or latest

-

-

181285.79

... More
27 (c )Supply of control panel (automatic type) for AT / local / generator supply

-

-

128355.3

... More
28Supply of link pull rod for 25KV d.o.fuse switch as per latest RDSO specification

-

-

9907.7

... More
Supply, erection, testing & commissioning of RTU as per RDSO specification for SP

-

-

1606891.99

... More
Modifications to existing SCADA

-

-

166600

... More
Supplying stacking at site (Quarry dust).

-

-

5103.54

... More
Drilling of holes for burried rails

-

-

1059.49

... More
Supply and erection of earth electrodes 10.0m long, 40mm dia. GI pipe.

-

-

17657.31

... More
Supply and erection of SS fastners ie., M-12 SS bolt assembly

-

-

61211.5

... More
Supply and fixing of 20mm copper rivets

-

-

4708.58

... More
Excavation for burried rail and refilling of soil (15.0x0.6x1.0) m

-

-

21188.6

... More
Supply and fixing of GI flat 75x8 mm thick

-

-

27589.62

... More
Supply and fixing of M-16 GI bolt.

-

-

294.29

... More
Supply and laying of precast kerb stone of concrete M-25 grade 30cmx20cm (in section / including chamfering as per design, if any) including fixing in 1:6 cement sand mortar and pointing with 1:2 cement mortar (1[cement] : 2 [sand ordinary]) including all excavation / refilling ramming and other inicidental works as required.

-

-

107438.45

... More
34(b)Cement concrete for foundation with stone ballast 40 mm size.

-

-

73406

... More
34(c)RCC work for foundation and plinth in ratio 1:2:4

-

-

341272.88

... More
34(d)Brick work for foundation plinth

-

-

27801.8

... More
34(e)Construction of retaining wall with stone masonry

-

-

20160.64

... More
34 (f) (i)Earth work in excavation and filling including compaction in Normal soil.

-

-

936.36

... More
34 (f) (ii)Earth work in excavation and filling including compaction in Hard soil.

-

-

1231.14

... More
34 (g)(i)Earth work, excavation for foundation in Normal soil.

-

-

936.36

... More
34 (g)(ii)Earth work, excavation for foundation in Hard soil.

-

-

1179.12

... More
34 (h)Excavation of pile of 100 mm to 200 mm dia up to 3.5 M deep.

-

-

1577.94

... More
34(i)Plastering of retaining wall with 1:6 cement mortar

-

-

3468

... More
34 (k)-Hand packed rubble soling

-

-

4976.58

... More
34(l)Pitching and grouting on side slopes with contractors stone including palstering of 20 mm thick over stone masonry

-

-

130266.75

... More
35Internal and External Lighting of Switching (SP/SSP) station building

-

-

25229.7

... More
Supply of 25kV single pole Vaccum Circuit Breaker (CB)

-

-

568116.24

... More
Supply of 25 kV Vaccume Interruptor as per RDSO specification

-

-

1146607.2

... More
Supply and erection of 240 V AC MCB type distributions Panel.

-

-

8400

... More
Supply of Disconnector assembly for 42 KV LA, 10KA rating

-

-

9858



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.