South Central Railway Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

South Central Railway - SCR Tender

Works
Telecommunication Services
Ireps
+10East Nimar, Madhya PradeshAkola, MaharashtraNanded, MaharashtraRajanna Sircilla, TelanganaEast Godavari, Andhra PradeshSangareddy, TelanganaHyderabad, TelanganaParbhani, MaharashtraBeed, MaharashtraAdilabad, Telangana
Opening Date23 Dec 2024
Closing Date17 Jan 2025
Tender Amount₹ 38,20,10,016.36 
Notes
Download

Costs

Summary

I) Macls Indoor And Outdoor Works Along With Provision Of Electronic Interlocking at Proposed Byepass Line At Ankai Connecting Mudhked-manmad Mainline To

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
SOR No.104 Supply of Metallic (MS) colour light Signal Unit.

-

-

1485200

... More
"Supply of Offset Bracket to suit 140mm dia CLS post with two numbers of U bolts and nuts complete." (Inspection by RITES)

24

4938

118512

... More
"Supply of Calling On Signal Unit complete with U Bolts as per RDSO DRG. No. SA.24351 (Adv.) or latest" (Inspection by RITES)

-

-

6

... More
Supply of Ground type position light shunt signal complete with base, pipe, arrow mark and hoods as per RDSO DRG. No. SA 23840 or latest. (Inspection by RITES)

15

6083

91245

... More
Supply of Post type position light shunt signal with hoods, arrow mark and offset bracket to suit 90mm sockets (CLS) with two numbers of 'U' bolts and nuts complete to fix shunt signal below main stop signal as per RDSO DRG. No. SA 23840 or latest. (Inspection by RITES)

4

3502

14008

... More
(SOR No.110) "Supply of Junction type/Direction type route indicator as per specification IRS:S 66-84 Amd. 1 or latest"

-

-

276408

... More
Supply of GKP type Location Boxes (a) Full size as perdrg. No. S&T/MFT/T.2378 (Inspection by RITES)

245

16216

3972920

... More
"Supply of relay fixing frame for full location box. The frame shall be of approximate size 940mmx150mm and made with powder coated MS angle of 25mmx25mmx 3mm. The frame shall have suitable holes to fix in full location box" (Inspection by Consignee)

200

853

170600

... More
(SOR No.205) "Supply of Hylam sheet, resin bonded, grade P3 as per IS specification IS 2036 of 1974 or latest of following size:" (Inspection by Consignee)

-

-

437698

... More
Supply of GI termination box (10 SWG) for point machine of size 45 cmx23 cmx12 cm 13 with double coat of enamel paint (outside: Black & inside: white) along with 2no's of MS angle of size 50x50x6mm of length 1000mm each, 2 numbers of 40mm GI pipe of length 450 mm & 150 mm with nuts/washers and teak wood plank of size 40 mmx25 mm for fixing of terminals. (Inspection by Consignee)

105

2902

304710

... More
Supply of Track feed battery charger to work on 110V AC for charging 1 or 2 or 3 or 4 lead acid cell of 80AH (10 Amps) used in track circuit as per RDSO Specn. No. IRS.S.89/2013 Ver 1.0 latest. (Inspection by RDSO)

210

8294

1741740

... More
"Supply of Track lead junction boxes fibre glass as per DRG.No.CWM-00597 of F.R.P 15 material to and specification IRS:S 23 along with fixtures i.e., one MS angle 50mmx50mmx5mm, 0.9m long, two numbers of G.l pipes of 25 mm dia, 500 mm long along with nuts and bolts and 500 mm long (grommet bushes, 60 mm ARA terminals-2 No's)" (Inspection by RITES)

602

1546

930692

... More
"Supply of B type chokes to as per specification IRS: S65- 83 Amd.l or latest" (Inspection by RDSO)

430

2313

994590

... More
SOR No.406 (a) "Supply of Stationary low maintenance secondary lead acid cells as per RDSO specification IRS: S88-2004 or latest. This includes supply of inter cell connectors, bolts, nuts, acid level indicating floats and vent plugs" (a) 2V, 80AH (Inspection by RDSO) 18

640

3315

2121600

... More
Supply of Hydrometer as per IS: 3104 (Part II)-1982 or latest. (Inspection by Consignee)

150

227

34050

... More
"Supply of Distilled water for topping of secondary cells as per specification IS 1106 or latest." (Inspection by Consignee)

3100

10

31000

... More
Supply of Track Feed Regulating Resistance disk type 0 Ohms to 30 Ohms as per DRG. No. SA 20161 66/M or latest. To be procured from RDSO approved firms. (Inspection by RDSO)

210

358

75180

... More
(SOR No.501) Supply of Plug-in type miniature tractive armature Non-AC immune, DC 21 neutral line relay complete with plug board, retaining clip/ATC Clip and connectors as per specifications BRS 930, lRS:S 23-88 Amd. 1 or latest, IRS: S 34-68 Amd. 6 or latest, IRS: S 67-85 Amd. 3 or latest (as applicable). (Inspection by RDSO)

-

-

4677350

... More
SOR No.502 Supply of 24 V DC plug-in type miniature tractive armature, AC immune 22 relay complete with plug board, retaining clip/ATC Clip and connectors as per IRS: S 23-88 Amd. 1 or latest, IRS: S 34-68 Amd. 6 or latest, IRS: S 60-78 Amd. 1 or latest, IRS: S 67-85 Amd. 3 or latest (as applicable). (Inspection by RDSO)

-

-

12310450

... More
Supply of AC immune, plug-in type, Style 'QTA2', 2F/1B DC Neutral track relay for 23 railway signalling track circuits with coil resistance 9 ohm, complete with plug board, retaining clip and connectors as per specifications: BRS 939A & 966 or Latest, IRS:S 23-88 Amd. 1 or latest, IRS: S 34-68 Amd. 6 or latest, IRS: S 67-85 Amd. 3 or latest (as applicable) with interlocking code FGHKX. (Inspection by RDSO) 24

210

4806

1009260

... More
SOR No.603 Supply of Terminal Block

-

-

3673000

... More
SOR No.605 Supply of non-deteriorating type of fuse holders and fuse links 240V AC/DC as per specification IRS: S 78-2006 or latest, IS 13703 (Part 2):1993 knife edge type fuse of El fuse link type (up to 20A) (Inspection by RDSO) 26

-

-

1631500

... More
SOR No.702 Supply of PVC insulated Wire Coils

-

-

2428050

... More
Supply of Battery Charger of Various capacity (a) 230V AC / 110V DC, 30A single phase, signalling/telecom. Installation as per specification IRS: S 86-2000 Amd. 4 or latest. (Inspection by RDSO/RITES)

13

110464

1436032

... More
SOR No.802 Supply of Transformer - Rectifier as per specification IRS: S 91-2014 Ver. 1.0 or latest.

-

-

817740

... More
Supply of Earth Leakage Detector (ELD) with configuration specified by Engineer In 29 charge and as per specification RDSO/SPN/256/2002 or latest with insulated tester, test probes, Mounting stand and Fuse board to isolate from distribution board as per requirement of channels. (c) Eight channel Earth Leakage Detector. (Inspection by RDSO)

11

88000

968000

... More
Supply of Data Logger of following capacity for remote monitoring of signalling 30 parameters and power supply arrangements with network as per specification IRS: S 99- 2006 Amd. 3 or latest with 64 input digital card as a spare and fuse monitoring PCBs for monitoring at least fifty 2A fuses with inbuilt modem cards for networking. (a) Data Logger with 512 digital inputs and 32 analog inputs (Inspection by RDSO)

11

497388

5471268

... More
Supply and installation of Fault analysis terminal for analysis of fault and generating reports for data logger installed at stations with minimum 19 inch display terminal with i5 processor 4GB RAM, HDD 1 TB, Windows 10 Licensed or better.(Inspection by Consignee)

6

66716

400296

... More
Supply of Safety Point Alarm unit to alert ASM to set the points against the blocked line. (Inspection by Consignee) 33

6

69582

417492

... More
SOR No.1002 Supply of Various Telephones and Telephone Power Supply unit 34

-

-

312552

... More
SOR No.1003 Supply of Various Telecom Cable 35

-

-

1542000

... More
SOR No.1004 Supply of Krone Termination Box complete with mounting

-

-

118830

... More
SOR No.1006 Supply of VF Transformer and accessories (a) Supply of VF Transformer with impedance ratio 470 : 600 ohms or 1120 : 600 (Type 4) or 1120 : 470 (Type 3) as per specification IRS : IC 22-76 or latest. (Inspection by Consignee) 37

125

909

113625

... More
SOR No.1009 Supply of OFC Related items

-

-

12737226

... More
"Supply of Electric Key Transmitter (EKT) rotary type complete as per DRG. No. SA 22601/Alt 4 or latest and specification IRS: 5 21-2001 Rev. 1.0 or latest. The ward number shall be as specified by the Engineer in-charge" (Inspection by RDSO)

30

7027

210810

... More
"Supply of 50mm x 6mm GI tape for interconnecting earth electrodes." (Inspection by Consignee)

3000

546

1638000

... More
"Supply of Universal Locks with one steel key for every ten locks or part there of(For example, if locks ordered is 10,1 key is to be supplied and if locks ordered is 20, 2 keys to be supplied. However, 2 keys to be supplied if locks ordered is between 11 and 19)" (Inspection by Consignee)

-

-

40

... More
"Supply of Electric Track Drilling machine shall be suitable for operating on 110V, 50Hz 41 AC / DC fully insulated and no-load RPM shall be 1900 / 1000 and the power input is 550W. Machine with suitable inter changeable track mounting stand and drilling to be designed with adjustable facility and along with a set of 20 no's of 7.2 mm dia Bosch MSS drill bit, Drill check dia. 13 mm and drilling dia in steel 8 mm/13 mm along with packing accessories." (Inspection by Consignee) 42

6

22602

135612

... More
SOR No.1716 Supply of following items for Station:

-

-

2686676

... More
SOR No.1719 Supply of Various Tools for S&T installation

-

-

423978

... More
Supply of FXS (subscriber line or hot line interface card) as per specification No. IRS-TC 68/2012 rev.0 amd.1 with latest amendments to be installed in Primary Drop Insert Multiplexer. Facility to drop 4 channels per station should be available. (Inspection by Consignee)

2

80730

161460

... More
Supply of interface cards for 2wire/4wire E&M,4 VF interface card as per specification No. lRS-TC 68/2012 rev.0 amd.1 with latest amendments (in omnibus or point to point mode for 24 channels. Number of cards are to be calculated as per the note given below) NOTE: A total of 24 46 circuits are to be dropped in omnibus mode or point to point at each primary drop insert multiplexer. The cards offered by the manufacturer may have different capacity, i.e. 4 channels or 8 channels per card. The number of cards to be supplied should be sufficient to drop 24 channels at each primary drop insert multiplexer. The capacity of each card should also be clearly mentioned. The unit given for this item is number of stations. The required no. of cards is to be calculated and quoted accordingly. (Inspection by Consignee)

3

118752

356256

... More
Location survey for cable route and preparation of tentative cable route plan as per the instructions of Engineer inCharge.

-

-

1

... More
SOR No.2502 (a) Excavation of trench, including marking of cable alignment, clearing 2 of jungle, roots of trees, bushes, trial pits if required, refilling with excavated soil, ramming and consolidation after laying of cables complete to the finished item of work in all type of Soil including soft rocky area as per RDSO Sketch No. SDO/CABLE LAYING/003, as directed by engineer incharge. (a) Depth of 1200mm and width of 300mm

153

-

15108750

... More
SOR No.2503 Cutting of Rock, concreting after cable laying with 1 cement: 2 sand: 4 3 graded stone aggregate 20mm nominal size and curing of concrete to the required number of days, except in bridges, culverts, level crossings, track crossings, cable pits and rocky soil including marking of cable alignment, clearing of debris etc., complete to the finished item of work as directed by engineer in-charge. All the material is to be arranged by contractor.

-

-

2413500

... More
When rock is visible for more than 0.5 Meter and up to 0.8 Meter from ground level, excavating the trench minimum 0.5 Meter and maximum 0.8 Meter, laying cable and concreting 200mmx200mm over the rocky surface after levelling with soil/ sand. (Chase cutting not required).

-

-

4

... More
Track crossing/Road Crossing by Horizontal Boring method at culverts/track/pucca road as per SCR Drg. No. 5770. This also includes insertion of HDPE pipe of 110 mm/G.l Pipe of 100 mm in the bore drilled (HDPE pipe/GI pipe is to be supplied by Railway)

8000

2264

18112000

... More
Trenching under Rails for crossing the track (Track Crossing) and refilling of trenches as per SCR Drg. No. 5768. The track crossing shall be done at right angles. The depth of cable trench 6 shall be 1.2 meter below the rail flange. The depth between top cable and the level of rail flange of the rail shall never be less than 1.0 meter. The ballast shall be stacked separately while making the trench and the earth soil shall be stacked separately. While re-filling the trench, the earth soil has to be filled first to the ground level and the ballast has to be properly put in the track. This work has to be done under supervision of supervisor of S&T and supervisor of P.Way.

4000

1139

4556000

... More
SOR No.2509 (a) Cable laying and meggering "(a) Laying different type of cables in the trench. Termination covered elsewhere."

250000

7

1750000

... More
Excavation of coil pit up to a depth of 1 meter and dia of 1.5 meter for providing coil at location box, point, signals etc., This includes back filling and ramming of trench / pit after laying the cable and consolidation of soil

370

1796

664520

... More
Breaking of Hard rock by Hydraulic excavator/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq m on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in charge.

1400

813

1138200

... More
SOR No.2517 (a) "Cable laying at culverts/bridges -High flood level Excavation of cable trench of 300mm width and 800 mm depth in the ramp from the foot of the culvert on to the top of the culvert by storing the ballast and the excavated soil separately and laying of HDPE/DWC/GI pipe( to be supplied by Railways). The pipe is to be laid , the cables required are to be drawn using bends( to be supplied by Railways) as per the drawing No.SK.15/11. After drawing the cables the bends are to be 10 concreted to a size of 300mmX1000mmX1000mm using required shuttering with I cement: 3 sand: 6 graded stone aggregate 20mm nominal size and curing for required days. Except the HDPE/GI/DWC pipe and bends, all other material is to be arranged by the contractor" (a) Excavation of trench at the culvert from foot of the culvert to top of it in the ramp to a size of 300mm width, 800mm depth by storing the ballast and the excavated soil separately laying of the HDPE/DWC/Gl pipe using couplers and bends as per drawing No.SK.15/11, drawing of cables through the pipe and refilling of the trench duly putting back the removed ballast in its proper place and shape.

7500

116

870000

... More
SOR No.2519 Supply & Laying of G.I Pipes with medium and threaded collar & coupler, quality to specification IS.1239 (part-I) 1990 and galvanised to specification IS 4736-1986

-

-

15881250

... More
Supply, transporting and installation of Concrete (RCC) Route Indicators at intervals of 12 50 meters as per instructions of engineer in charge as per drawing no. SK 12/10.They should be of standard RCC with letters "SCR S&T cable" as per type of cable laid to drawing. In case of telecom quad cable joint locations it shall be painted with GREEN and ORANGE colour for normal indication of cable path. (Inspection by RITES)

3350

1204

4033400

... More
SOR No.2523 "Provision and laying cement concrete (including transportation of all the material)"

-

-

3340850

... More
SOR No.2525 (a) Jungle Cutting "(a) Clearing jungle including uprooting of rank 14 vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of cleared jungle to a distance of 50 m outside the periphery of the area cleared (Measurement is to be done as per area cleaned)"

12000

10

120000

... More
Videography of work spots such as Signal/LB foundation, cable trench with depth 15 indicators at every 10 mtrs with reference to landmark such as RE mast or hectometre post in MPEG or any other format specified by engineer in charge. The video recording shall be supplied in CDs/Pen drive 16

137

460

63020

... More
SOR No.2601 Location box foundation and erection

-

-

4216150

... More
Cable termination including fixing terminals, fuses, LDs, Meggering of cables and recording the readings.

-

-

18

... More
SOR No.2608 "Supply, painting and fixing of gland plate for Location box as per site requirement." (a) Full Location Box 21

260

776

201760

... More
SOR No.2609 Tie Bar Fencing

-

-

1458250

... More
Fabrication, supply and erection of conventional Earth to Siqnallinq/Telecom equipments - Excavation of earth and providing earth pipe of size 50mm dia. 3.5mm thick 2.0 m. long G.I. pipe of heavy quality with masonry tub constructed around at earth locations as specified by site 22 Engineer. Alternate layers of 30kgs-charcoal and 30kgs-common salt to be filled in the pit while closing. The pipe perforation etc., to be carried out as per drawing No. SK 10/10. The earth pipe to be connected to the function with cable as supplied by Railways. The reading should be painted on the masonry tub. The masonry tub of 300 mm x 300 mm x 300mm (along with Kundi) should be covered with cement slab.

735

6652

4889220

... More
"Supply and Installation of "A"-Type LPS (ERICO or similar make) Model No: System 3000 or similar. a) Air Terminal - 1No. b) Insulated 2m FRP Mast Black -1No. c) Upper Termination Kit - 24 1No. d) Lower Termination Kit -1No. e) Lightning Event Counter -1No. f) Down Conductor - 30 Mtrs. g) GI pipe 50mm dia and 3.5 mm thickness as per SCR Drawing No.5777. h) Installation to be done as per SCR Drawing No.5777. Installation also includes fixing of LEC Counter with suitable MS box enclosure and running of down conductor through PVC pipes and connecting the same to nearby earth electrode. All material required for installation will be provided by contractor.(Inspection : RDSO/RITES)"

11

315000

3465000

... More
Installation of single earth(maintenance free) including the following:- welding and fixing of copper tape (used as bus bar) welding of cadmium bronze cable to copper plate using material supplied vide item no. 1,2 of SPD of Sch-A. All the material supplied for mounting of copper tape, exothermic weld materials, tools and fixtures for welding copper tapes shall be arranged by contractor. a) Digging /Auguring/Boring of single earth pit of 100mm to 125 mm dia to the depth of approx. 2.8 meter. b) Insertion of 3.0 meter electrode and penetrating it at least 0.2 meter by pushing gently with sledge hammer where the natural soil is assumed. c) Filling of earth pit with earth enhancement compound (EEC) in slurry from and backfilling. d) Carrying out exothermic weld 25 connection on single earth electrode to a copper tape of 150X25X6mm. e) Carrying out exothermic weld connection on the copper tape of 150X25X6mm on earth electrode for connecting two 35 Sq mm cables for redundancy. f) The exothermic welding material for bonding the earth system shall be procured from RDSO approved firms, which includes graphite moulds, clamps, weld metal powders. g) Digging a trench to a depth of at least 0 .5 Mtr. and run the two 35 Sq mm earth conductor (procured against supply item) from earth pit to MEEB. h) Routing and termination of two 35 sq mm earth conductors in trench from earth pit to 300X25X6mm MEEB, which is to be fixed inside the equipment room with two insulation studs. i) 300X300X300 mm (inside dimension) concrete earth pit with a concrete lid, approx 50mm thick with pulling hooks, shall be provided to cover the pit. Back side of the cover will be painted in black and date of the testing and earth resistance value shall be written

75

6338

475350

... More
Foundation and erection of Colour light signal which includes a) Excavation of pit, casting concrete foundation as per SCR Drg. No. 5772 using metallic templates, for erection of Colour light Signals 4 aspects (foundation bolts, cement, river sand, stone jelly of size 20/20mm dia and all 26 other miscellaneous materials required for the work shall be supplied by the contractor). b) Erection of surface base, signal post, mounting of Colour Light Signal up to 4 aspects complete on signal post/ offset bracket, LED fixing, plumbing of the signal through sealing gap between Surface base and signal post, fixing of ladder with platform complete and concreting of ladder shoe, fixing of number plates, marker board, termination tail cables, wiring of signal unit, provision of EWS locks, and painting of one coat of red oxide and two coats of aluminium/enamel paints. When the aspect is fixed on offset bracket using 'U' bolts and nuts, a through bolt shall be provided by drilling of hole in the signal pole to prevent the offset bracket from sliding down. (Supply of surface base, offset bracket, CLS pole, CLS aspects complete, ladder with shoes and platform, LED aspects, current regulators and wire coils will be supplied by Railways). ('U' bolts and nuts, through bolts and nuts, cement, stone jelly 20/25mm dia, river sand, Signal Colour Rings, all fixing bolts and nuts, teak wood, paints PVC/Nylon sleeves, enamelled number plates, enamelled marker boards, EWS locks, and all other miscellaneous materials for the work shall be supplied by the contractor). 60 percent (%)Payment after completion of work mentioned at (a) and remaining 40 % after completion of work at (b))

96

15360

1474560

... More
Foundation & erection of Shunt signal which includes a) Excavation of pit and casting concrete foundation as per Drg. No. SG/CN/02/10 using metallic templates, for erection of ground type colour light Shunt signal. (Foundation bolts and nuts, cement, river sand, stone jelly of size 20/25mm and all other miscellaneous materials for the work shall be supplied by the contractor).b) Erection of 27 Ground type shunt signal complete including surface base, signal post, LED aspects, number plate, termination of tail cables, wiring of signal unit, provision of EWS locks and painting of one coat of red oxide and two coats of Aluminium /.enamel paint, (Supply of Ground type shunt signal complete including surface base, signal post, LED unit is to be supplied by Railways). [ EWS locks, enamelled number plates, bolts and nuts, lead wool, paints and all other miscellaneous materials shall be supplied by the contractor). (60 % Payment after completion of work mentioned at (a) and remaining 40 % after completion of work at (b)).

15

6805

102075

... More
Fixing of offset bracket using 'U' bolts and nuts erection of posts type shunt signal, wiring of LEDs, termination of tail cables, provision of EWS lock, fixing of number plate and painting of 28 one coat of red oxide and two coats of aluminium / enamelled paint. The work also includes drilling suitable holes on the CLS post and provision of a through bolt with nut to prevent the offset bracket from slipping down (Supply of Post type shunt signal, LED unit is to be supplied by Railways). EWS locks, enamelled number plates, bolts and nuts, lead wool, paints and all other miscellaneous materials shall be supplied by the contractor)

9

2364

21276

... More
SOR No.2804 Fixing of junction type route indicator - 1 way to 6 way - complete / fixing of additional limb to the existing route indicators, termination of tail cables, wiring as per approved 29 circuits diagram, provision of required number of EWS locks, wire mesh and painting. (Supply of junction type Route Indicators - complete and additional limb is not covered in this schedule). [Fixing bolts and nuts, EWS locks, wire mesh, PVC/Nylon sleeves, paints and all other miscellaneous materials shall be supplied by the contractor]

-

-

34389

... More
Fixing of Offset brackets using 'U' bolts and nuts, erecting of Calling On Signals/'A' marker lights, termination of tail cables and wiring, provision of EWS lock, number plates/markers 30 boards and painting. The work also includes drilling suitable holes on the CLS post and provision of a through bolt with nut to prevent the Off-set bracket from slipping down. (Supply of Calling On Signal / 'A' marker light, LED aspect/ holders and bulbs, wire coils and off set brackets will be supplied by Railways). ['U' bolts and nuts, through bolts with nut, EWS lock, Enamelled number plates, PVC/Nylon sleeves, paints and all other miscellaneous materials shall be supplied by the contractor.

12

1998

23976

... More
Manufacturing, Supply, painting and fixing of markers of G/P/C/A/AG/IB Markers as per IRSEM Drg.No.19-D10 on MS sheet of thickness 3mm. Miscellaneous material required for fixing Markers is to be supplied by contractor.

320

469

150080

... More
SOR No.2808 Supply and fixing of wire mesh for the following signals, duly painted with black enamel in two coats.

-

-

6728

... More
Provision of SCREEN on signals when they fall within 2 meters from the live conductor 33 by expanding metal (size 20mm x 60mm strand 3.25 mm wide and 1.6mm thick) as per the instruction of site engineer in charge. This includes supply of all materials including connection with earth electrode as per SCR Drg. No. 5767.

10

4194

41940

... More
Supply and fixing of cross bar on signal (signal not in use) made of hard wood of size 1000mm x 100mm x 20mm. The cross bar shall be painted white as per Signal Engineering Manual. All material required for installation shall be supplied by contractor.

-

-

34

... More
Strengthening of foundations of signals, Full/Half location boxes up to a height of 30 35 cm, by carrying out the earth work around the foundation, ramming of the earth, carry out masonry work from bottom of earth work using country stones and cement masonry to prevent the earth from slipping down the bank.

1350

760

1026000

... More
Fixing of universal point machines and wiring on PSC/Wooden sleepers as per standard 36 drawing. Wiring as per circuitry includes fixing & wiring of point contactor unit frames and controlling relays, fixing and wiring of point termination box, fixing of crank handle ward plate of required configuration and Ground connections, P-clamp insulations, setting, stretcher bars etc., [All miscellaneous material required such as nuts, bolts, washers are to be arranged by contractor]

84

6460

542640

... More
Fixing of Track lead junction box on angles (50 x 50 x 6 mm size), drilling one hole on either side of the box of suitable size and fixing track lead junction box by the side of the track, drilling 38 4 holes of 7.2 mm dia. on Rail, connecting double track leads with bond pins, running track lead wire, termination of track lead wire on ARA terminals duly fixing the same inside the TUB Teak wood board bolted inside the track lead junction box. (Fixing angles, bolts, nuts and teak wood boards to be supplied by the contractor)

610

505

308050

... More
Wiring of Track circuits feed end, relay end complete with TLDs, batteries, chargers, 39 Chokes, track relays, double lead wires, providing insulation etc,. Connected with track commissioning of track circuit including provision of bracket for TLD covers and painting. Anti-tilting arrangement has to be done for chargers & batteries. All miscellaneous material required for installation shall be supplied by contractor.

210

1509

316890

... More
Painting of particulars of Glued Joint on rails/track circuit no. on TLJ boxes as per 40 particulars issued by Engineer in charge. Before painting on surface of the Glued Joint Rails/TLJ boxes shall be cleaned thoroughly. Painting shall be done with approved quality of standard paints like Asian/Johnson/ Nicholas /Berger etc. All the men and materials shall be arranged by the contractor and the colours scheme shall be as per the instructions of Engineer in charge.

600

149

89400

... More
Manufacture, supply and fixing of Sighting Board (size 535mm X 1800mm) with higher 42 intensity grade, retroreflective sheet on 2mm Aluminum alloy, sheet 14 gauge (0.6 Sq.mm / LC) as per Drg no.SK113/89 with MS angle of 75X75X6 mm with 6 meter length including paint, excavation of pit and concrete foundation etc. as per the instructions of sight in charge (All necessary materials to be arranged by the contractor)

18

11763

211734

... More
Fabrication, Supply and fixing of CALLING ON instruction boards, STOP boards/ 43 BSLB/Shunting Limit Board/Auto section board or any other board with engineering grade reflective sticker of size 600X1 000 mm GI sheet, with MS angle of 75X75X6 mm with 6 meter length including paint, excavation of pit and concrete foundation etc. as per the instructions of sight in-charge. All necessary materials to be arranged by the contractor)

12

5314

63768

... More
SOR No.3205 Crank Handle Box/KLCR Box for Crank Handle

-

-

621720

... More
"Fixing of PVC pipes & bends, drawing of required wires through the same up to functions like control telephone, Dy.control telephone, magneto phones inside SM's office as per circuit diagram. This includes supply and fixing of required DPDT and rotary switches, PVC pipes and bends 25mm dia with 2mm wall thickness, Lightening dischargers and painting of particulars." 47

8

5406

43248

... More
SOR No.3212 Fixing of the following on pre-erected relay racks.

-

-

433080

... More
SOR No.3213 Indoor Painting including particulars of CT rack, relay rack, Equipment 48 particulars (IPS, Data logger, UFSBI, ELD, Charger, battery particulars, block instrument, VDU and any other equipments in relay room/ IPS room / Battery room I Telecom room / Maintenance room I SM room), earthing particulars including ring earth particulars outside as applicable and any other indoor particulars as per technical specification for following stations:

-

-

196006

... More
Installation, testing and commissioning of Data Logger which includes the software configuration, validation, taking test print, networking to nominated location for monitoring, changing of EPROMS if any and alterations to data base in HQ/SSE offices where ever required. 50

11

36208

398288

... More
Implementation, testing and commissioning per station of point reversal alarm.

6

7286

43716

... More
Supply & Installation of Proximity switch (CE approved) for relay room door & connecting with the data logger as per the following specifications. 1. Supply and fixing of different sizes of PVC casing/pipes as required by Railway at site by fixing/clamping to the wall or laying in floor 51 for indoor wiring purposes. Necessary hardware materials such as Galvanized screws and washers, wooden pegs, teak etc, deep boxes, Junction boxes, Normal bends or diversion bends etc. to be arranged by the contractor. 2. Supply & fixing of PVC Flexible pipe of 25/40/50mm dia sizes of reputed make. 3. Drawing of fresh new wires from the relay base/proximity switch to another relay base/Data logger as per the new wiring without affecting the other wires. This also includes testing of wires using buzzer of the new wires drawn once before soldering and once after soldering. 52

11

1798

19778

... More
SOR No.3221 Fabrication of Keys and Plate configuration for points

-

-

81144

... More
"Fabrication, supply and installation of NI panel of size 12"" x 24"" x 12"" made in 18 gauge MS sheet."

6

12397

74382

... More
Installation and wiring of all power supply equipment viz DC Distribution system, 56 chargers, Transformers, batteries etc, and its wiring (lacing, button/ thread copper eyelets/lugs required for crimping 10 sq.mm wire are to be supplied by contractor). For power panel, bolts, nuts, fixing screws are to be arranged by contractor. ON/OFF Switches, digital Meters, Hylam sheet and wire coils will be arranged by railways.

11

16629

182919

... More
SOR No.3402 (a)"Initial Charging of Secondary Cells with uninterrupted Power Supply: - " (a) 2 volts 80 AH. 58

560

328

183680

... More
SOR No.3403 Installation of DG Set

-

-

173362

... More
Installation, wiring, earth connections with SEEB, testing and commissioning of IPS 59 system. Wires/cables shall be supplied by Railways, Charging of battery is covered elsewhere. Minor items like casing/capping, Ladder, insulators, Lugs, Lacing of cables etc., where required to be supplied by contractor. Grouting and masonry work of the IPS to be done. Work includes installation of charged batteries and their wiring with IPS.

11

21746

239206

... More
Installation, Calibration and commissioning of Earth Leakage detector 8 to 12 channels as per instructions of engineer in charge

11

11802

129822

... More
Supply and wiring of Polymeric Positive Temperature CoEfficient Device self resetting type (PPTC) of 2A rating suitable for railway applications of reputed make. The PPTC fuse shall be wired by soldering suitable flexible wire on both ends (all material except flexible wire has to be arranged by contractor).

-

-

61

... More
SOR No.3503 Testing and commissioning the entire signalling installations jointly with 62 the Railway representative at site at the Stations/ LC gates/lBS/Auto Signalling covered under various schedules of the Contract, and ensuring that all the signalling gears are installed and adjusted as per the existing rules. 63

-

-

199356

... More
"Supply and installation of Electronic Flasher unit, able to drive 2 No. of flasher lights."

10

2572

25720

... More
"Supply and fixing of Electronic Hooter unit 24/110 DC of approved design/make able to drive 2 No. of Speakers of 8 ohms 15W."

10

2732

27320

... More
Supply, erection and fixing of retro reflective type BPAC Warning boards/lBS Legend 65 Board of size 1000X600X3 mm. The boards shall be provided with Retro Reflective type BPAC Warning boards. MS Angle, stone jelly of size 20/25mm dia, river sand, cement, fixing bolts and nuts, paint and all other miscellaneous materials required for the work shall be supplied by the contractor

36

9564

344304

... More
SOR No.3901 Design of SIP in Auto Cad. Initially, contractor shall submit 3 copies for approval of Railways. One set will be returned duly approved for making a fair copy or for re- 66 submission for approval after incorporating the changes as required by Railways. After carrying out changes, three Hard copies to be submitted for Railway Approval. After approval, Auto Cad copies to be submitted in USB pen drive along with approved copy in Tracing film and six copies of final approved drawing (Ammonia Print or print as approved by Railway) in properly bound booklet along with its scanned copy.

-

-

171906

... More
SOR No.3902 Design of SWRD in Auto Cad. Initially, contractor shall submit 3 copies for approval of Railways. One set will be returned duly approved for making a fair copy or for re- 67 submission for approval after incorporating the changes as required by Railways. After carrying out changes, three Hard copies to be submitted for Railway Approval. After approval, Auto Cad copies to be submitted in USB pen drive along with approved copy in Tracing film and six copies of final approved drawing (Ammonia Print or print as approved by Railway) in properly bound booklet along with its scanned copy.

-

-

88905

... More
SOR No.3905 Design of Cable Route Plan (Distant to Distant) including details of all 69 track crossing/Horizontal boring/Cable Loop/ Cable Joints etc. in AUTOCAD & submission of coloured paper copies for approval. After approval, Auto Cad copies to be submitted in USB pen drive along with approved copy in Tracing film and six copies of final approved drawing in plastic cover (Ammonia Print or print as approved by Railway) in properly bound booklet along with its scanned copy.

-

-

55287

... More
SOR No.3906 Design of Cable Distribution Plan in AUTOCAD & submission of Three 70 paper copies for approval as per the practice of SCR. After approval, AUTOCAD copies to be submitted in USB pen drive along with approved copy in Tracing film and six copies of final approved drawing in plastic cover (Ammonia Print or print as approved by Railway) in properly bound booklet along with its scanned copy

-

-

47430

... More
SOR No.3907 Design of Track Bonding Plan in AUTOCAD & submission of Three paper 71 copies for approval. After approval, AUTOCAD copies to be submitted in USB pen drive along with approved copy in Tracing film and six copies of final approved drawing in plastic cover (Ammonia Print or print as approved by Railway) in properly bound booklet alongwith its scanned copy.

-

-

41664

... More
SOR No.3908 Design of Circuit Diagrams in AUTOCAD consisting of the items as 72 mentioned below & submission of Three paper copies for approval (i) Wiring Diagrams (ii) Relay Disposition Charts (iii ) Contact Analysis and Fuse Particulars (iv) Termination Chart for Panel Interlocking (v) CT Rack Particulars

-

-

572832

... More
SOR No.3911 Supply of Original Tracing of Location Box Drawings (Including Contact Analysis, Fuse Particulars etc) along with softcopy in CD after incorporating all the corrections. 74

-

-

10649

... More
SOR No.3919 Fabrication and Supply of Different Boards

-

-

112092

... More
Supply of thick Kodak photo paper with lamination and different lettering in languages and required size as per the instructions of site in-charge.

120

5679

681480

... More
Supply of portable work station to run along with El configuration tool, Data Inputs, Simulation, Functional testing, diagnostic and troubleshooting.

6

126896

761376

... More
Fabrication, Transportation and fixing of aluminium ladder at site made of Aluminium angle of size 38mmx5mm width 280mm ,Flat size 25 mm x 5mm with powder coated colour as 77 desired by engineer in charge at site and fixing, Drilling of suitable holes for fixing of Hylam sheet 3mm thickness on ladder and 2 No's of PVC trough 100 mm with cover fixed on Hylam sheet along the ladder with all fixtures necessary ancillary materials required for fixing to be supplied and as directed by engineer in charge at site.

3250

4098

13318500

... More
Supply, fabrication, installation and fixing of panel operator consol with arrangement to 78 fix 55" VDU's -Reset boxes, and other S&T gadgets. This shall be made of not less than 18mm thick plywood or better materials with storage facility of approved colours with contractors' materials, lead, lift and manpower as per the instructions of engineer in charge and as per the enclosed drawing.

6

354447

2126682

... More
Supply and installation of offline UPS 1000VA, 30 mm backup as per instructions of engineer in charge. 80

12

11286

135432

... More
Supply and fixing of Fire Extinguisher CO2 type (Capacity 4.5 KG)

88

8171

719048

... More
Supply, transportation, Installation, Testing & Commissioning of UL/EN/FM/Vds/LPCB approved microprocessor based Networkable Analog Addressable and modular type of Fire Alarm Control Panel (FACP) with display, in built charging facility and provision of GSM module suitable to send SMS to configured mobile number. The panel should be equipped with sufficient no. of loops and provision of expandability as per RDSO specification no. RDSO/SPN/217/2021 Ver. 3 or latest. The 81 control panel shall be the central processing unit of the system, receiving and analysing signals from probe type by metallic heat detectors, UV and IR flame detectors, heat and smoke multi sensor, LHS interface and manual call point, providing Audible and visual information to the user. The panel shall have the connectivity of TCP-IP suitable for programming and remote monitoring. The panel shall have dedicated RS 232 serial port for direct PC or Modem connection, for interfacing with existing data logger, optional remote printer (as per RDSO specification no RDSO/SPN/217/2016 Ver. 1 or latest. (SOR--2024) (Inspection by RDSO)

11

261419

2875609

... More
Supply, Installation, Testing & Commissioning of resettable, Addressable multi sensor (heat & smoke) which is fully compatible with analogue addressable protocol, electronically addressed as per RDSO/SPN/217/2018 Ver. 2 d1 or latest. (SOR-2024) (Inspection by RDSO)

11

6237

68607

... More
Supply, Installation, Testing & Commissioning of 24V/ 2 Amps power supply for aspiration detector with battery backup shall comply to RDSO/SPN/217/2016 Ver. 1 or latest. (SOR- 2024) (Inspection by RDSO)

11

67603

743633

... More
Supply, Installation, Testing & Commissioning of electronic hooter cum strobe with min 85dB output Approval- UL/LPCB Listed and shall comply to RDSO/SPN/217/2016 Ver. 1 or latest. (SOR- 2024) (Inspection by RDSO)

11

9595

105545

... More
Supply, Installation, Testing & Commissioning of 2X1.5sqmm ATC Fire survival 85 flexible/armoured cable with back box, glands & other accessories.Armoured & unarmoured (Cl) cables should meet fire performance test under simultaneous action of Flame, water stress and impacts on single sample at 950°C for minimum 2 hours, certified by LPCB or equivalent complying to RDSO/SPN/217/2016 Ver. 1 or latest. (SOR-2024) (Inspection by RDSO)

11

60016

660176

... More
Fabrication and supply of wall mounted maintainer's Tool Kit frame made out of MS 86 sheet 10 gauge with powder coated as desired colour at site of size 1.5 Mtrs. Length X 0.8 Mtr. Width X 0.15 Mtr. Depth with all fixtures for mounting individuals, tools inside the board and in front with Acrylic sheet 4mm thickness with locking arrangements and all necessary fixtures to fix on wall.

9

18699

168291

... More
Providing the services of Computer oriented Technical manpower to carryout works like 87 drawing, computation, write up etc., between 08:00 Hrs to 20:00 Hrs of the day with all expenses of transportation, accommodation, food, consumables etc., with all ascents, descents, taxes, octorio, cess, fees, duties with contractors cost etc., as per special conditions/specifications/ regulations and as directed by engineer in charge.

1050

784

823200

... More
Provision of Lookout person round the clock in 12 Hours shift beat from Up Home Signal to Down Home signals to avoid theft of signalling assets.

4000

640

2560000

... More
Arranging of skilled and unskilled workers with required tools during point blocks for removal of S&T assets to give way for track machines and re-fixing the removed assets after insertion/removal of point.

65

4102

266630

... More
Installation, wiring, testing & commissioning of 2 wire DTMF Selective Calling Telephone with power supply.

23

922

21206

... More
Termination of telecom cable at cable hut and panel room, fixing of block filter units and cable termination boxes to the wall in panel room, wiring VF transformers, block filter units, block 93 bell equipment including drawl of cable through GI / PVC pipe, termination on to terminals and doing other works associated with commissioning of derivation of block working as per instructions of supervisor in charge of work. Note: Cables, CTB, Filter units, Block bell equipment, VF Transformers, GI Pipe, and Cement will be supplied by Railways. All other materials including Angles, PVC pipe etc will be arranged by the Contractor. 94

6

2670

16020

... More
SOR No.4611 Provision of Emergency Socket

-

-

142615

... More
"Supply & installation of Rack 19"" wall mount 17U with front glass door and lock and 95 key including the following: 1. 1 U Cable manager - 1 No. 2. 1 U Cantilever tray - I No. 3. AC distribution box 5X5 amps - 1 No. 4. Front panel H/W PKT of 10 Sets - I No. 5. Cooling fan of 230V AC operated"

11

17545

192995

... More
"Laying of HDPE duct 40133 mm dia in the trenches and in protective works already provided."

245

7410

1815450

... More
Blowing of armoured optic fibre cable (OFC Cable supplied by Railways) into the duct supplied vide other NS item of supply portion by using blowing machine and associated works. 10% of 97 OFC length to be blown extra on both ends of Duct i.e. total 20% of Duct length. Before blowing the duct integrity shall be tested. If any defect is found during duct integrity test, the entire length of HDPE duct from one chamber to another chamber is to be replaced by the contractor at his own cost. Payment will be made as per the length of Duct from which OFC is Blown

215

10956

2355540

... More
Excavation of jointing pit and provision of RCC/FRP joint / Loop chambers of 90 Cms. Inner dia 60 Cms depth and 3mm thickness with two pieces of top cover with hooks each and bottom 98 cover with hole for drainage and cable entry as per Drg. No. RAILTEL/SR/OFC/ 2009/12 and as directed by Engineer to be provided at every joint location and at every Kilometre loop etc., The chamber shall be filled with sand mixed with ariti-stermic power, back filling and ramming of trench after HDPE duct laying, splicing and commissioning.

110

6344

697840

... More
Supply and Installation of OFC joint enclosure and splicing of Optic fibre cable (24 fibres) and testing as per technical specification No. GR OJC-2/02 Sept 2003. Supply of Splice Enclosure (24 fibre) shall be of TVS make Part No.1500-L18X-XX or similar as per Board specification of TEC.& as per RDSO/SPN/TC/68/2014 Revision 1.0 amd 1 or latest . All materials including Fusion splicing machine used for fibre splicing and, OTDR for testing and other testinq materials if any shall be arranqed by the contractor.

-

-

99

... More
Supply and installation of rack mounted 24 fibre Distribution Management System 100 (FDMS) of size 1U, of Reputed/Branded company make as per specification RDSO/SPN/TC/37/2020 Revision 4.0 with latest amendments. The FDMS shall include 24 SC-PC/Required adaptors having insertion loss less than or equal to 0.1dB and 24 numbers 900 micron 1.5m SC-PC/Required pigtails. 101

10

23712

237120

... More
Testing of all 24 fibres of OFC cable after splicing end to end in a section (Long Haul)

6

21512

129072

... More
Supply and fixing of different sizes of PVC casing /Pipes as required by Railway at site by fixing /clamping to the wall for indoor wiring purposes. All the material required for fixing PVC casing/Pipes are to be supplied by contractor.

3000

48

144000

... More
Supply and installation of 230 volts AC / 48 volts, 25 Amps DC (2 1 configuration) SMPS battery charger as per RDSO spec. RDSO/SPN/TC/23/99 (Ver-4) Amdt.-1 or latest.(Inspection by RDSO)

6

83721

502326

... More
Supply and installation of 48 volts 200 AH maintenance free VRLA battery in charged condition as per RDSO specification lRS:S-93/96(B) (Amd. 1 ) or latest. (2 volts 200 AH- 24 Nos. each set).(Inspection by RDSO)

6

104042

624252

... More
Supply and installation of 19' - 42 U Rack complete with fittings for housing SDH equipment, FDMS, DDF and other equipment like cable managers, completely wired using krone module and other equipment like runaway ladders etc., as per technical specification below. It should be able to lock all the equipment with only order wire Telephone outside the rack. The rack should be 105 of APW President/ Rittal make or similar. The components of the rack are specified below. It includes transportation and installation of rack in prefab/building at specified stations. 1. Rack S33 42U 600W x 600D - 1 No. 2. Fixed side panels 42U x 600 o - 2 Nos. 3. Front Glass door plain 42U/600W - 1 No. 4. Rear MS Door Plain 42U/600W - 1 No. 5. Castor with brakes-2 Nos. 6 Fans directly mounted on the top 48V DC 90 CFM-2 Nos. 7. Krone mounting bracket - 01 Nos. 8. MCB Mounting panel with MCBs - a. 32 Amps, MCBs(DP) - 2 Nos. & 6Amps MOBs (DP) - 6 Nos. 9. Earth continuity Kit - 01 No. 10. Equipment Trays - 5 Nos. 11. Channel with cable loops 42U - 2 Nos"

9

41962

377658

... More
"Supply, installation, testing and commissioning of managed expandable rack type STM-4, equipped STM-1, ADM S1.1, as per technical Specification no.GR No.: TEC/GR/TXISDA- 003/02/APR-2010 with 2 Nos.STM-1 aggregate Optical interface upgradable to STM-4, 21 Els, and minimum 8 Nos. of 10/100 base T Ethernet port, Order wire, Power supply unit, sub rack, DDF, 106 Installation materials, manuals and other accessories. The equipment should be TEC/BSNL/RDSO approved .The equipment should be fully wired for its ultimate capacity and provide redundancy for Power supply and Synchronisation. It shall be possible to use the full capacity of the equipment by adding additional tributary cards. The up gradation of STM-1 to STM-4 shall be without change of any internal hardware of the STM equipment. The STM equipment shall have in-built L2 switch for Ethernet ports. Make -Tejas or similar. (Inspection by RDSO)"

6

311694

1870164

... More
Supply and installation of programmable Primary Digital Drop Insert Multiplexer fully wired for 30 Channels complete with all accessories from RDSO approved vendor as per RDSO specification IRS TC 68-2012 Rev.0 (with latest amendment) including connectors and cables required for installation including 100 pair Krone type MDF. Each channel card shall have minimum four channels per card. The single sub rack shall be capable of being equipped up to mm. 60 Channels 107 without additional power supply unit. The MUX shall be wired & equipped with following circuits: 1. 2 Wire/4 Wire E&M VF circuits (Minimum 16 No. Ckts) 2. FXO circuits: 6 nos.3. FXS circuits Subs/Hotline circuits along with ringer card etc.: 08 No's 4. Acquisition card as per design 5. Data User manual. 6. This also includes connecting all pigtails, optical patch cords etc to the SDH equipments. This also includes connection of SDH and primary MUX equipment with all interface cards to the 48V Bus including termination on DDF taking PVC cable over runway or a wall and termination of VF interface circuits to the Krone Termination box. (Inspection by RDSO)

6

274869

1649214

... More
SOR No.4638 Maintenance of 6 quad cables till handing over or at least for six months. 108 This includes regular testing of Quad parameter from Station to Station, EC socket testing and recording in format specified by Railways. This item will commence only after joint testing of 6 quad cables with required parameters in a block section.

-

-

197790

... More
Supply of Fibre boards of 'Alter the points immediately on arrival of the train as per GR:3.38 (2)' in bilingual i.e., in Hindi and English of size 4.5" X 12" (Inspection by Consignee)

6

1627

9765

... More
Supply of Intergated access device supporting 2 Optical interface supporting distance 20 kms with 1+1 protection (One dual core and one single core), 8*E1 ports and four 100Mbps ETH Interface through optical interface. To work on quad auto change over feature for E&M Interface. 8*E1 2 can also be used as uplink with supporting autom media change over between optical and E1 for PCM Service. upto 8*EM interface supporting 2W/4W configurable. 4 port 2 Wire voice connecting hotline and autophone ( 4 port each FXO & FXS). Supports Multidirection upto 5 direction. All service cards are modular and pluggable cards and which are upgradable & expandable in field. Unit to support DC power (18V-72VDC) and AC vide adaptor 230VAC/110VAC. Unit to be rack mountable and supplied with rack mounting MAKE:MRO-TEK or similar. (Inspection by RITES)

28

193200

5409600

... More
Supply of VHF Digital Radio set with standard Accessories, 6 DB GP Antenna, Co-axial 3 RG-213 Cable 30Mtr with both End connectors 30Mtr, Power Supply Unit for Base station 10 Amp, Battery 12V DC 80 AH. Make: Motorola XiR M8668i or similar (2 number of Software/harware Kit for installation along with necessary software also to be supplied) (Inspection by RITES)

6

109504

657024

... More
High density polyethylene pipes(HDPE) of 110mm outer Dia,10mm wall thickness along with one coupler for every 6 meters as per specification no IS 4984:2016 with latest amendmnents and material grade PE 80(Inspection:RITES)

20000

675

13500000

... More
Manufacture and Supply of Auto CLS/SPD power termination Box with 8 terminals. (Inspection by Consignee)

9

4484

40356

... More
Supply of A3 Multi Functional Colour Printer of Model Xerox VERSALINK C7130 Series or latest or similar. (Inspection by Consignee)

2

282020

564040

... More
Supply of OFC Integrated device 1U height Optical Module integrated supporting dual 7 core OFC and one 100 Mbps Ethernet port, four E1 ports & Optical distance upto 40 Kms. Device to support dual OFC ports supporting Pt-Pt redundancy. Power supporting AC or DC through single socket. Accessories : E1 cable. d). Should have atleast 5 years of past experience of same device supply to Railway. (Inspection by RITES)

14

30800

431200

... More
Supply of 9U equipment rack of HCL /valrack / Bestnet make as perspecification. 8 Compatible with 19"international standards, front door withtoughened glass quality, cable insertionon top & bottom pannel to provide easy cable entry. Top section with 2 Fanmounting provision with accessories:cable manager, cooling 2 Fan tray, PDU 5A- 6 socket. (Inspection by Consignee)

9

11114

100027.35

... More
Supply of Pure Sine Wave Inverter of 24V DC input and 230v AC output with 47-63 Hz Frequency (KVA Rating as per OEM Recommendation) (Make:Microtek or better) (Inspection by Consignee)

18

21830

392940

... More
Supply, placing and covering of RCC duct from Home to Home as per para 7.3 and Annexure 8 & 10 of RDSO guidelines for cable laying detailed in technical specification as per drg.No.5778A. (Inspection by RITES)

13500

1928

26035695

... More
Supply of Label Printing machine - CPM-100HG5 with Accessories Along with White, Black, Red, Yellow, Green & Blue Colours Inkribbon Along with Sheet Free with Machine. (Inspection by Consignee) 12

2

272800

545600

... More
Supply of TME Card (Inspection by RDSO)

4

43424

173696

... More
Supply & installation of CT boxes with wago terminals (50 pair) of WAGO make. Consists of part nos:280-870 (100nos),280-374 (1nos),249-116(2nos),210-229/pw11-0000(1nos)and Metallic box for outdoor use with locking facility. (Inspection by Consignee)

20

4165

83300

... More
Supply & Installation of 6A/16A Dual pole MCB of Make:Legrand of similar and as specified by supervisor in-charge.(Inspection by Consignee)

-

-

14

... More
"Supply of Flexible PVC insulated 3- core x 2.5 sq. mm (36/0.3 mm dia)multi strand power cables provided for each of the display boards shall confirm to specification no. IS: 694:1990 reaffirmed 1995 or latest. Make: Finolex,Sudhakar or any IS brand.(Inspection by Consignee)

3000

72

217710

... More
Junction box with required MCB as per the site requirement Make: Lagrand/latest. (Inspection by Consignee)

12

6500

78000

... More
Design of circuits(interface and logic) and preparation of wiring diagrams (imcluding supply of test prints , as made documents , TSA documents etc) for carrying out alterations work as 17 per approved plan.FAT as per modified application logic.Testing (including SAT during NI working ) and Commissioning as per modified application logic. Alterations to the relay rack wiring as per modified interface circuits along with the supply of complete necessory wiring materials for alterations. (Inspection by Consignee)

2

1740731

3481462

... More
Signal post Telephone with Talk back facility consisting of 1 Master + 1 Slave, operating voltage 110V AC/24V DC suitable for OFC. (Inspection by Consignee)

6

29500

177000

... More
Smart RFID marker SM1500 Telephone HSN code 90314900 Part No.SML-T. (Inspection by Consignee)

1330

2265

3013248

... More
RFID Marker Locator-Telephone HSN Code 90318000 Part No.SML-T. (Inspection by Consignee)

2

333350

666700

... More
Supply of sealed Lead Acid cells MF 12V/7AH make Exide CS7-12 or similar (as per instruction site incharge)" (Inspection by Consignee)

15

721

10815

... More
Supply of Display Unit for EI MTC similar to LG 55'' (139.7cm) 4K Smart UHD TV of Model No.55UP7500PTZ or latest. (Inspection by Consignee)

4

49000

196000

... More
Installation charges for auto change over module.

9

7500

67500

... More
Laying of 50x6mm G.I. tape for interconnecting of earth electrodes.( This includes excavating of trench to a suitable depth as per site requirement and refilling of the same after laying of GI tape as per requirement. 3

3000

148

444000

... More
Installation, testing and commissioning charges of BPAC with dual sensor.

16

56180

898880

... More
Supply and fixing of Safety slogans in three languauge (Telugu, Hindi and English) with minimum of size of the Slogans 200mm X 1000mm or suitable to the slogans proportionate payment for each sheet.

90

650

58500

... More
Supply ,transportation and installation of Cable termination rack similar to Medha Servo 6 Drives or similar with all fixtures ,Supporting Angles,Triangle Bases,Insulators,Din Rails duly fixed on rack with powder coated and color of rack to be matched with the relay rack supplied by Medha Servo Drives and as directed by engineer incharge at site.

20

27280

545600

... More
Supply ,transportation and installation of Cable ladder rack with all fixtures ,Triangle 7 Bases,Insulators duly fixed on rack with powder coated and color of cable ladder to be matched with the relay rack supplied by Medha Servo Drives and as directed by engineer incharge at site.

20

8600

172000

... More
Breaking of RCC concrete in Relay Room/ Panel Room for drawing cables to ground floor and 1 st floor

11

3700

40700

... More
Supply and laying of 50 Sq.mm. insulated copper cable in suitable PVC pipe. (Inspection by Consignee) All other materials required for installation to be arranged by contractor.

1800

700

1260000

... More
Supply, Installation ,Testing and Commissioning of Resettable type Analouge LHS cable ,( As per RDSO Specification No.RDSO/SPN/217/2012 ver 2.0 or latest).(Inspection by RDSO)

4400

1271

5593236

... More
Supply, Installation ,Testing and Commissioning of Analogue Controller for LHS cable ,( As per RDSO Specification No.RDSO/SPN/217/2012 ver 2.0 or latest) (Inspection by RDSO)

11

90042

990466.07

... More
Supply and Installation of Ultrasonice High Variable Frequency Rat Repellant Make:Varna.

90

2625

236250

... More
Provision of Safety equipment keeping stand in station building for DySS room safety equipments.

6

19966

119796

... More
Excavation of Cable trench in all kind of soil except hard rocky areas including clearing 17 of roots of trees, rocks, bushes etc., to a depth of 0.5 mtr-0.6 mtr to accommodate the duct under NS item and to a width of 0.5 mtr. This shall include refilling of earth as per instructions of Engineer Incharge. Laying of cables is not included in this schedule. In case of less depth, payment will be done proportionate to depth subjected to minimum depth of 500 mm. 18

14000

150

2100000

... More
Installation of MAPLE 4C and fibre multiplexer system at station

12

12921

155052

... More
Supply and installation of rack mounted 24F FMS fiber of Bestnet Make or similar to suit connectivity for switches and FMS. (Inspection by Consignee ).

12

15600

187200

... More
Supply. installation. testing and commissioning of Fixed 2 mega pixel bulet - network camera with housing Specification : 1/2.8 Progressive Scan CMOS,Digital WDR, 3D DNR, 10 meters IR range, 12V DC±10%, ICR Make: AXIS, MATRIX,BOSCH)

88

7665

674544.64

... More
Supply. installation. testing and commissioning of 8CH NVR network video recorder Make: AXIS,MATRIX,BOSCH.

11

20657

227230.08

... More
Supply and installation of 21.5 inch Monitor with all connecting cables to monitor CCTV cameras at location.

11

10653

117187.84

... More
Supply, installation, testing and commissioning of 8 port 10/100 POE ethernet switch Make: DIGISOL,HIKVISION or DLInK

11

17149

188643.84

... More
Supply, installation, testing and commissioning of 12 port 10/100 ethernet switch. Make: DLInK 25

11

8444

92892.8

... More
Overall commissioning of cameras and arrange network to head quarters

7

32480

227360

... More
Supply , fixing and termination of RJ-45 jacks to CAT-6 cable.Make:D-Link

110

15

1714.9

... More
Supply and installation of 12U rack with depth of 600mm along with power manager , trace and cooling fans with all standard accessories. 28

19

12000

228000

... More
Errection of 42 U rack as per instructio of SSE/Tele incharge at site.

9

823

7407

... More
Installation of SDH equipment FMS racks etc., including DDF, LADDERS (25mm Thick x 30mm width), RUNWAY, PATCH CORDS, 'P' MUX and their testing and commissioning.

6

11000

66000

... More
Manufacture and Supply of Tele Console Cabinet (1000X1500mm) as per following details:a) Complete body fabricated as per drawing with 1.6mm MS Sheet. b) Double door arrangement with 1.2mm MS Sheet with locking arrangement. c) Separote box for Battery with door. 30 d) 5mm clear acrylic sheet will be fitted in the doors. e) Equipment fixing; arrangement with hinged frame in the body. f) Cable troy fixing arrongement as per drowing. n) Three point locking arrangement on one door and tower bolts on second door. Universal Lock and cam lock arrangement for battery box. h) Powder coating of all metal parts i) PVC coble troys as per requirement assembled in position.j)DIN rails as per requirement assembled in position. 31

6

26748

160489.44

... More
Laying of different cables for camera work

275

1000

275000

... More
Supply and installation of 10/100 single mode media converter with accessories including connecting cables for networking of cameras to Central place. Make: MROTEK/ D- Link/RAD/Team Engineer and as per specification given in Annexure-XVIII.

9

4000

36000

... More
Lime wash on walls/foundations at site as directed by site in-charge one coat with quick lime of approved quality. 35

2500

3

9025

... More
Supply and filling of sand as per the Technical Specifications 36

650

615

399769.5

... More
Supply and spreading of 20mm ballast for Perimetric Earth/Ring Earth of S&T buildings.

-

-

118048

... More
"Construction of cable coil pit back side of relay room , Goomty and IB hut etc., as per 37 site requirement, it includes digging of pit, construction of side walls with bricks, coilling and bunching of cables, filling the pit with sand and minimum 10cm layer of concreting on top with 1 cement : 3 sand :6 graded stone aggregate of 20mm normal size. All Material and labour for the work to be arranged by the contractor . Item to paid as for size of pit in cubic metres . " 38

165

3867

638196.9

... More
Fabrication ,Transportion and fixing of name plates on TLJB 39

440

600

264000

... More
Fabrication ,Transportion and fixing of name plates on point termination box.

96

800

76800

... More
Preparation of Station Working Rules, CRS papers etc as practice inRailways for yards/LC Gate/IBHincluding xerox

-

-

40

... More
Supply of Hot Standby Electronic Interlocking System (Centralized/ Distributed) excluding Panel Processor (Hot Standby) with Signalling functions up to 125 functions as per function table enclosed along with 5% spares for the cards/modules/PCB, connectors/couplers, fuses, all relays, 1 crimp contact, convertors etc. used, tools, manuals and Instruments as per RDSO specification RDSO/SPN /192/2019 ver. 2.0 or RDSO/SPN/ 203/2011 ver. 1.0 or latest.Note: Payment will be made for only vital bit as per function table attached by Railways, no payment will be made for non Vital bits such as Counter bits, SM key Bits, Read back bits and any potential free contact bits of DC-DC converter or Modem of El. (Inspection : RDSO)

6

7832317

46993902

... More
Supply of commercial grade operator VDU of size 55' Full HD, with backlit LED, with HDMI/DVI port, Inbuilt Speaker, required HDMI/DVI cables for connectivity and other miscellaneous item required for installation. (Inspection by Consignee)

12

226320

2715840

... More
Supply of fan less embedded industrial grade computers (Similar to Moxa V2406A or 4 better ) with all accessories such as key board, mouse, antivirus etc. of industrial grade as per approved Specification as recommended by RDSO (TAN No. STS/TAN/3007 Version 1.0 or latest) (Inspection by Consignee)

12

182900

2194800

... More
Commissioning of Electronic Interlocking system

6

25604

153624



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.