Rural Development Department Tender

... More
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Rural Development Department - RDD Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date26 Mar 2025
Closing Soon10 Apr 2025
Tender Amount₹ 1,35,73,930 
Notes
Download

Costs

  • EMD

    ₹ 1,35,739
  • Document Cost

    ₹ 26,000
  • Tender Fee

    ₹ 500

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing and laying Cast in situ / Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete work in foundations like raft, strip foundations, grillage and footings of reinforced cement concrete columns and steel stanchions, excetra including bailling out water, formwork, cover blocks, compaction, curing and roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel), excetra complete, with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. with fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (using ARTIFICIAL SAND). Item / Page No : 13 / 178 Specification No : Bd.F.3, B-7 Spec. Page No : 298, 38-40 Additional Specifications : 1. The appropriate mix design shall be got done well in advance from the approved government laboratory and the same shall also be got approved from Engineer in-charge, before starting the work. 2. Cement from the same stock sent for mix design shall be used for concreting work. 3. The minimum cement for reinforced cement concrete / plain concrete to ensure durability / strength shall be as per IS 456-2000 with latest ammendment. If actual cement required / consumed is more than the provision in the IS code / approved mix design, no claim for that shall be entertained and cost for that shall be bourned by the contractor. 4. Before concreting work, cement from each consignment shall be got tested and if the strength of cement varies considerably from the approved mix design, the mix design should be got modified according to strength of fresh cement available in stock and concreting work should be done according to modified mix design. 5. For every consignment of cement, a sample shall be got tested as per norms and frequency of Vigilance and Quality Control Circle, Pune. As regards testing of cement it will be entire responsibility of the contractor. 6. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

180.6

8223

1485236.34

... More
Providing and laying cast in situ / Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, compaction, roughening if special finish is to be provided and curing excetra completet (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 33 / 180 Specification No : Bd.F.5, B-7 Spec. Page No : 300, 38-40 Additional Specifications : 1. The appropriate mix design shall be got done well in advance from the approved government laboratory and the same shall also be got approved from Engineer in-charge, before starting the work. 2. Cement from the same stock sent for mix design shall be used for concreting work. 3. The minimum cement for reinforced cement concrete / plain concrete to ensure durability / strength shall be as per IS 456-2000 with latest ammendment. If actual cement required / consumed is more than the provision in the IS code / approved mix design, no claim for that shall be entertained and cost for that shall be bourned by the contractor. 4. Before concreting work, cement from each consignment shall be got tested and if the strength of cement varies considerably from the approved mix design, the mix design should be got modified according to strength of fresh cement available in stock and concreting work should be done according to modified mix design. 5. For every consignment of cement, a sample shall be got tested as per norms and frequency of Vigilance and Quality Control Circle, Pune. As regards testing of cement it will be entire responsibility of the contractor. 6. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

25.14

15231

382913.63

... More
Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including centering, formwork, cover blocks, compacting, finishing and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement, including cover block) Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin excetra with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 23 / 185 Specification No : Bd.F.12, B-7 Spec. Page No : 304-305, 38-40 Additional Specifications : 1. The appropriate mix design shall be got done well in advance from the approved government laboratory and the same shall also be got approved from Engineer in-charge, before starting the work. 2. Cement from the same stock sent for mix design shall be used for concreting work. 3. The minimum cement for reinforced cement concrete / plain concrete to ensure durability / strength shall be as per IS 456-2000 with latest ammendment. If actual cement required / consumed is more than the provision in the IS code / approved mix design, no claim for that shall be entertained and cost for that shall be bourned by the contractor. 4. Before concreting work, cement from each consignment shall be got tested and if the strength of cement varies considerably from the approved mix design, the mix design should be got modified according to strength of fresh cement available in stock and concreting work should be done according to modified mix design. 5. For every consignment of cement, a sample shall be got tested as per norms and frequency of Vigilance and Quality Control Circle, Pune. As regards testing of cement it will be entire responsibility of the contractor. 6. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

13.47

8118

109354.85

... More
Providing second class burnt brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 in foundations and plinth of inner walls / in plinth of external walls including bailling out water manually, striking joints, on unexposed faces, racking out joints on exposed faces and watering, excetra complete. (using ARTIFICIAL SAND). Item / Page No : 1 / 197 Specification No : Bd.G.1 Spec. Page No : 313 Additional Specifications : 1. The brick shall be got tested before use, from the Government laboratory at the rate of one batch of 15 bricks for every 50000 bricks or part therof at the contractors cost for the following. A) Crushing strength:- i. Dry condition 5 bricks ii. Wet condition 5 bricks B) Water aborption 5 bricks 2. In addition, bricks shall be tested for size, shape and soundness. 3. The proportion of cement mortar shall be 1:6. 4. Minimum two drums of water shall be provided to masons for soaking of bricks at each place where masons are working. 5. For mixing of mortar steel forms of required size only shall be used For mixing of mortar, steel tough or back platform shall be used. 6. The brick work shall be cured for a minimum period of 14 days. 7. The joints on both faces shall be raked to a depth of not less than the thickness of joints for affording good bond plaster. 8. Hold fast of door or window frames shall be embedded in cast in situ 1:2:4 cement concrete blocks of required size without any extra cost. 9. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

25.23

8790

221793.15

... More
Filling in plinth and floors with approved excavated materials in 15 centimetre to 20 centimetre layers including watering and compacting, excetra complete. Item / Page No : 36 / 157 Specification No : Bd.A.10 Spec. Page No : 262-263

520.51

125

65532.21

... More
Filling in plinth and floors with contractors material / brought from outside and approved by Engineer In-Charge, in 15 centimetre to 20 centimetre layers including watering and compaction, excetra complete. Item / Page No : 37 / 157 Specification No : Bd.A.11 Spec. Page No : 263-264

9.03

1171

10579.55

... More
Providing second class Burnt Brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 superstructure including striking joints, racking out joints, watering and scaffolding, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 5 / 197 Specification No : Bd.G.5 Spec. Page No : 315 Additional Specifications : 1. The brick shall be got tested before use, from the Government laboratory at the rate of one batch of 15 bricks for every 50000 bricks or part therof at the contractors cost for the following. A) Crushing strength:- i. Dry condition 5 bricks ii. Wet condition 5 bricks B) Water aborption 5 bricks 2. In addition, bricks shall be tested for size, shape and soundness. 3. The proportion of cement mortar shall be 1:6. 4. Minimum two drums of water shall be provided to masons for soaking of bricks at each place where masons are working. 5. For mixing of mortar steel forms of required size only shall be used For mixing of mortar, steel tough or back platform shall be used. 6. The brick work shall be cured for a minimum period of 14 days. 7. The joints on both faces shall be raked to a depth of not less than the thickness of joints for affording good bond plaster. 8. Hold fast of door or window frames shall be embedded in cast in situ 1:2:4 cement concrete blocks of required size without any extra cost. 9. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

43.52

9041

393488.26

... More
Providing and laying cast in situ /Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks,laying/pumping, compaction and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete.With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 52 / 181 Specification No : Bd.F.6, B-7 Spec. Page No : 300-301, 38-40 Additional Specifications : 1. The appropriate mix design shall be got done well in advance from the approved government laboratory and the same shall also be got approved from Engineer in-charge, before starting the work. 2. Cement from the same stock sent for mix design shall be used for concreting work. 3. The minimum cement for reinforced cement concrete / plain concrete to ensure durability / strength shall be as per IS 456-2000 with latest ammendment. If actual cement required / consumed is more than the provision in the IS code / approved mix design, no claim for that shall be entertained and cost for that shall be bourned by the contractor. 4. Before concreting work, cement from each consignment shall be got tested and if the strength of cement varies considerably from the approved mix design, the mix design should be got modified according to strength of fresh cement available in stock and concreting work should be done according to modified mix design. 5. For every consignment of cement, a sample shall be got tested as per norms and frequency of Vigilance and Quality Control Circle, Pune. As regards testing of cement it will be entire responsibility of the contractor. 6. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

16.27

13642

221955.34

... More
Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap/ granite / quartzite/ gneiss metal for reinforced cement concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks,laying / pumping, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 70 / 182 Specification No : Bd.F.8, B-7 Spec. Page No : 302-303, 38-40 Additional Specifications : 1. The appropriate mix design shall be got done well in advance from the approved government laboratory and the same shall also be got approved from Engineer in-charge, before starting the work. 2. Cement from the same stock sent for mix design shall be used for concreting work. 3. The minimum cement for reinforced cement concrete / plain concrete to ensure durability / strength shall be as per IS 456-2000 with latest ammendment. If actual cement required / consumed is more than the provision in the IS code / approved mix design, no claim for that shall be entertained and cost for that shall be bourned by the contractor. 4. Before concreting work, cement from each consignment shall be got tested and if the strength of cement varies considerably from the approved mix design, the mix design should be got modified according to strength of fresh cement available in stock and concreting work should be done according to modified mix design. 5. For every consignment of cement, a sample shall be got tested as per norms and frequency of Vigilance and Quality Control Circle, Pune. As regards testing of cement it will be entire responsibility of the contractor. 6. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

25.28

15190

384022.16

... More
Providing and laying cast in situ / Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete waist slab and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood / steel formwork, steel props, compaction, finishing uneven and honeycombed surface with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement, including cover block) Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin excetra with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 25 / 185 Specification No : Bd.F.13 Spec. Page No : 305 Additional Specifications : 1. The appropriate mix design shall be got done well in advance from the approved government laboratory and the same shall also be got approved from Engineer in-charge, before starting the work. 2. Cement from the same stock sent for mix design shall be used for concreting work. 3. The minimum cement for reinforced cement concrete / plain concrete to ensure durability / strength shall be as per IS 456-2000 with latest ammendment. If actual cement required / consumed is more than the provision in the IS code / approved mix design, no claim for that shall be entertained and cost for that shall be bourned by the contractor. 4. Before concreting work, cement from each consignment shall be got tested and if the strength of cement varies considerably from the approved mix design, the mix design should be got modified according to strength of fresh cement available in stock and concreting work should be done according to modified mix design. 5. For every consignment of cement, a sample shall be got tested as per norms and frequency of Vigilance and Quality Control Circle, Pune. As regards testing of cement it will be entire responsibility of the contractor. 6. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

1.62

13227

21427.82

... More
Providing and laying cast in situ / Ready Mix Cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete pardi of required thickness including centering, formwork, cover blocks, compacting, finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement, including cover block) Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin excetra with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 17 / 185 Specification No : Bd.F.11, B-7 Spec. Page No : 304, 38-40 Additional Specifications : 1. The appropriate mix design shall be got done well in advance from the approved government laboratory and the same shall also be got approved from Engineer in-charge, before starting the work. 2. Cement from the same stock sent for mix design shall be used for concreting work. 3. The minimum cement for reinforced cement concrete / plain concrete to ensure durability / strength shall be as per IS 456-2000 with latest ammendment. If actual cement required / consumed is more than the provision in the IS code / approved mix design, no claim for that shall be entertained and cost for that shall be bourned by the contractor. 4. Before concreting work, cement from each consignment shall be got tested and if the strength of cement varies considerably from the approved mix design, the mix design should be got modified according to strength of fresh cement available in stock and concreting work should be done according to modified mix design. 5. For every consignment of cement, a sample shall be got tested as per norms and frequency of Vigilance and Quality Control Circle, Pune. As regards testing of cement it will be entire responsibility of the contractor. 6. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

0.41

16905

6931.4

... More
Providing and fixing in position thermo mechnically treated FE-500 steel bar reinforcement of various dias for reinforced cement concrete pile caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardis, copings, fins, arches, excetra as per detailed designs, drawings and schedules including cutting, bendding, hooking the bars, binding with wires or tack welding and supporting as requied complete. (For Ground Floor) Item / Page No : 33 / 188 Specification No : Bd.F.17 Spec. Page No : 306 Additional Specifications : 1. Steel to be used must be as per Indian Standard : 1786 (1985) with latest amendments and manufactured by approved and reputed make. 2. Steel to be used must be procured directly from the manufacturers or from authorised agent of main producers. 3. Various diameters of TMT-FE-500 steel bars brought on site of the work shall be got tested category wise and lot wise, as directed by the Engineer In-Charge and minimum 50 percent of testing should be done in the departmental laboratory.

23.58

94248

2221916.64

... More
Providing internal cement plaster 20 milimetre thick in single coat in cement mortar 1:3 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 8 / 209 Specification No : Bd.L.4 Spec. Page No : 368 Additional Specifications : 1. The surface to be plastered shall be first cleaned and thoroughly wetted for 24 hours and got checked from Engineer in-charge before starting the work. 2. Item includes rounding of all internal and external junctions, corners, jambs, etc. as directed by the Engineer in-charge. 3. Finishing shall be plain and in line, level and plumb. 4. Curing shall be done by sprinkling water on the surface for minimum period of 14 days. 5. Application of sand faced treatment shall be commenced only after passing the base coat Engineer in-charge. 6. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

455.85

421

192049.61

... More
Providing sand faced plaster externally in cement mortar using approved screened sand in all positions including base coat of 15 milimetre thick in cement mortar 1:4 using waterproofing compound at one killogramme per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment of 6 to 8 milimetre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days, scaffolding, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 11 / 209 Specification No : Bd.L.7 Spec. Page No : 369 Additional Specifications : 1. The surface to be plastered shall be first cleaned and thoroughly wetted for 24 hours and got checked from Engineer in-charge before starting the work. 2. Item includes rounding of all internal and external junctions, corners, jambs, etc. as directed by the Engineer in-charge. 3. Finishing shall be plain and in line, level and plumb. 4. Curing shall be done by sprinkling water on the surface for minimum period of 14 days. 5. Application of sand faced treatment shall be commenced only after passing the base coat Engineer in-charge. 6. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

242.35

681

165258.47

... More
Providing and fixing machine cut machine polished 18 milimetre to 20 milimetre thick telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone for treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on a bed of 1:4 cement mortar including float, filling joints with neat cement slurry, curing, polishing and cleaning, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 35 / 216 Specification No : Bd.M.22 B Spec. Page No : 390 Additional Specifications : 1. The work shall be carried out as per instructions of Engineer in-charge. 2. The work shall be carried out as per the sample approved by the Engineer in-charge and kept in the office of the Executive Engineer. 3. The edge of step should be chafered or rounded as directed. 4. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

11.14

4386

48860.6

... More
Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 milimetre to 605 milimetre X 590 milimetre to 605 milimetre of 8 milimetre to 10 milimetre thickness and confirming to Indian Standard 15622-2006 (Group BIa) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 40 / 217 Specification No : Bd.M.12 Spec. Page No : 385 Additional Specifications : 1. The work shall be carried out as per instructions of Engineer in-charge. 2. The work shall be carried out as per the sample approved by the Engineer in-charge and kept in the office of the Executive Engineer. 3. Water absorption should not be more than 0.05 percent. 4. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

131.75

1258

165767.85

... More
Providing and laying vitrified mirror / glossy finish tiles having size 590 milimetre to 605 milimetre X 590 milimetre to 605 milimetre of 8 milimetre to 10 milimetre thickness and confirming to Indian Standard 15622-2006 (Group BIa) of approved make, shade and pattern for dado and skirting in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 41 / 217 Specification No : Bd.M.12 Spec. Page No : 385 Additional Specifications : 1. The work shall be carried out as per instructions of Engineer in-charge. 2. The work shall be carried out as per the sample approved by the Engineer in-charge and kept in the office of the Executive Engineer. 3. Water absorption should not be more than 0.05 percent. 4. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

11.87

1336

15868.41

... More
Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 milimetre with lock plate of 3.15 milimetre thickness reinforced with 35 milimetre X 35 milimetre X 5 milimetre angle section fitted with sliding bolts and handles for both sides, deep mild steel channel section of depth and thickness not less than 65 milimetre and 3.15 milimetre respectively with hold fast arrangements, mild steel bracket plate 300 milimetre X 300 milimetre X 3.15 milimetre minimum size and shape with square bar, suspension shaft of minimum 32 milimetre diametre, hood cover of mild steel sheet not less than 0.9 milimetre thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer, excetra complete. (Indian Standard : 6248-1979) - without mechanical gear (For Ground Floor) Item / Page No : 24 / 248 Specification No : Bd.T.55 Spec. Page No : 510

79.23

5065

401347.49

... More
Providing and Fixing Processed Stone Cladding on wall surface/ plywood surface. reinforced cement concrete pardi/ Wall and all type of Interior, Exterior Compound wall and Gate excetra of cladding processed stone with material of Processed clay, Wooden chips, Silica sand, Cement, glass fibre reinforced concrete admixtures, Colour pigments, Fiber up to thick of 230 milimetre / 25 milimetre including scaffolding,fixing of screw, excetra (As directed by Engineer in Charge) Item / Page No : 192 / 409 Additional Specifications : The work shall be done as per instructions of Engineer in charge.

6

9019

54115.8

... More
Providing and fixing hume pipe septic tank 900 milimetre diameter with vent pipe and cap including excavation and laying. Item / Page No : 18 / 275 Specification No : Bd.V.45 Spec. Page No : 575

1

17791

17791.6

... More
Providing and applying plastic emulsion paint of approved quality, colour and shade to new surfaces in three coats including scaffolding, preparing the surfaces (excluding primer coat), excetra complete. Item / Page No : 14 / 228 Specification No : Bd.P.6 Spec. Page No : 414

10

141

1416

... More
Providing and applying two coats of exterior weather shield paint of approved manufacturer and of approved colour to the plastered surfaces including cleaning, preparing the plaster surfaces, applying primer coat, scaffolding, if necessary and watering the surface for two days, excetra complete. (For Ground Floor) Item / Page No : 26 / 225 Additional Specifications : 1. The shade of paints shall be got approved by the Engineer in-charge before use. 2. The paints shall be of Indian Standards and from approved manufactures. The paints shall be got approved before use.

10

309

3094.5

... More
Providing and fixing 90 centimetre X 60 centimetre granite name plate engraving 10 centimetre height letter, figures including painting the letters / figures with approved colour and shade complete. Item / Page No : 12 / 294 Specification No : Bd.W.7 Spec. Page No : 586-587

1

9049

9049.7

... More
Compacting the hard murum side widths including laying in layers on each side with vibratory roller including artificial watering, excetra complete. Item / Page No : 26biii / 130 Specification No : RD.38 Spec. Page No : 210 Additional Specifications : The contract rate is for one square metre instead of one kilometre as mentioned in the specification.

289.17

22

6370.42

... More
Providing and laying cast in situ / Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, compaction, roughening if special finish is to be provided and curing excetra completet (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 33 / 180 Specification No : As per Item No 5 Spec. Page No : --- Additional Specifications : As per Item No 5

12.49

15370

191982.54

... More
Providing second class Burnt Brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 superstructure including striking joints, racking out joints, watering and scaffolding, excetra complete. (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 5 / 197 Specification No : As per Item No 10 Spec. Page No : --- Additional Specifications : As per Item No 10

43.37

9121

395599.45

... More
Providing second class Burnt Brick masonry with conventional / Indian Standard type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of 2 bars of 6 milimetre diameter / 2 hoop iron strips 25 milimetre X 1.6 milimetre placed at every third course, properly bent and bounded at ends, scaffolding, racking out joints and watering, excetra complete. (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 6 / 197 Specification No : Bd.G.7 Spec. Page No : 316 Additional Specifications : 1. The brick shall be got tested before use, from the Government laboratory at the rate of one batch of 15 bricks for every 50000 bricks or part therof at the contractors cost for the following. A) Crushing strength:- i. Dry condition 5 bricks ii. Wet condition 5 bricks B) Water aborption 5 bricks 2. In addition, bricks shall be tested for size, shape and soundness. 3. The proportion of cement mortar shall be 1:4. 4. Minimum two drums of water shall be provided to masons for soaking of bricks at each place where masons are working. 5. For mixing of mortar steel forms of required size only shall be used For mixing of mortar, steel tough or back platform shall be used. 6. The brick work shall be cured for a minimum period of 14 days. 7. The joints on both faces shall be raked to a depth of not less than the thickness of joints for affording good bond plaster. 8. Hold fast of door or window frames shall be embedded in cast in situ 1:2:4 cement concrete blocks of required size without any extra cost. 9. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

90.41

1262

114160.71

... More
Providing and laying cast in situ /Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks,laying/pumping, compaction and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete.With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 52 / 181 Specification No : As per Item No 11 Spec. Page No : --- Additional Specifications : As per Item No 11

17.78

13766

244768.37

... More
Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap metal for reinforced cement concrete chajja as per detailed design and drawings including centering, formwork, cover blocks, compacting, finishing and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate of natural sand/V.S.I. quality Artificial Sand (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 5 / 184 Specification No : BDF-9, B-7 Spec. Page No : 303-304, 38-40 Additional Specifications : 1. The appropriate mix design shall be got done well in advance from the approved government laboratory and the same shall also be got approved from Engineer in-charge, before starting the work. 2. Cement from the same stock sent for mix design shall be used for concreting work. 3. The minimum cement for reinforced cement concrete / plain concrete to ensure durability / strength shall be as per IS 456-2000 with latest ammendment. If actual cement required / consumed is more than the provision in the IS code / approved mix design, no claim for that shall be entertained and cost for that shall be bourned by the contractor. 4. Before concreting work, cement from each consignment shall be got tested and if the strength of cement varies considerably from the approved mix design, the mix design should be got modified according to strength of fresh cement available in stock and concreting work should be done according to modified mix design. 5. For every consignment of cement, a sample shall be got tested as per norms and frequency of Vigilance and Quality Control Circle, Pune. As regards testing of cement it will be entire responsibility of the contractor. 6. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

0.62

15330

9504.66

... More
Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap/ granite / quartzite/ gneiss metal for reinforced cement concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks,laying / pumping, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 70 / 182 Specification No : As per Item No 12 Spec. Page No : --- Additional Specifications : As per Item No 12

31.17

15330

477839.22

... More
Providing and laying cast in situ / Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete waist slab and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood / steel formwork, steel props, compaction, finishing uneven and honeycombed surface with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement, including cover block) Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin excetra with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 25 / 185 Specification No : As per Item No 13 Spec. Page No : --- Additional Specifications : As per Item No 13

1.62

13347

21623.19

... More
Providing and laying cast in situ / Ready Mix Cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete pardi of required thickness including centering, formwork, cover blocks, compacting, finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement, including cover block) Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin excetra with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 17 / 185 Specification No : As per Item No 14 Spec. Page No : --- Additional Specifications : As per Item No 14

3.26

17061

55620.65

... More
Providing and fixing in position thermo mechnically treated FE-500 steel bar reinforcement of various dias for reinforced cement concrete pile caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardis, copings, fins, arches, excetra as per detailed designs, drawings and schedules including cutting, bendding, hooking the bars, binding with wires or tack welding and supporting as requied complete. (For First Floor) Item / Page No : 33 / 188 Specification No : As per Item No 15 Spec. Page No : --- Additional Specifications : As per Item No 15

7.36

95145

700559.26

... More
Providing and fixing mild steel grill work for windows, ventilator, excetra 20 kilogram per square metre as per drawings including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting, excetra complete. (For First Floor) Item / Page No : 1 / 264 Specification No : Bd.U.1 Spec. Page No : 537 Additional Specifications : 1. The work shall be done as per instructions of Engineer in charge. 2. The grill design shall be got approved from the Engineer in-charge before use.

25.74

2224

57245.76

... More
Providing and fixing in position (as per Indian Standard : 1868/1982) aluminium sliding window of two tracks with rectangular pipe having overall dimentsions 63.50 milimetre X 38.10 milimetre X 1.02 milimetre at weight 0.547 kilogram per running metre and window frame bottom track section 61.85 milimetre X 31.75 milimetre X 1.20 milimetre at weight 0.695 kilogram per running metre. Top and side track section 61.85 milimetre X 31.75 milimetre X 1.30 milimetre at weight 0.659 kilogram per running metre. The shutter should be of bearing bottom 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre. Interlocking secion 40 milimetre X 18 milimetre X 1.10 milimetre at weight 0.469 kilogram per running metre and handle section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre and top section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre as per detailed drawing and as directed by Engineer in-charge with all necessary aluminium sections, fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 milimetre thick plain glass with all required screws and nuts excetra complete. - With powder coating without box. (For First Floor) Item / Page No : 40 / 252 Additional Specifications : The work shall be done as per instructions of Engineer in charge.

23.04

5151

118679.04

... More
Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 milimetre X 38 milimetre X 1.22 milimetre box type, 5 milimetre thick sheet glass louvers of approved quality, excetra complete. (For First Floor) Item / Page No : 68 / 259 Additional Specifications : The work shall be done as per instructions of Engineer in charge.

2.7

3671

9913.19

... More
Providing internal cement plaster 20 milimetre thick in single coat in cement mortar 1:3 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing, excetra complete. (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 8 / 209 Specification No : As per Item No 16 Spec. Page No : --- Additional Specifications : As per Item No 16

540.74

425

229922.65

... More
Providing sand faced plaster externally in cement mortar using approved screened sand in all positions including base coat of 15 milimetre thick in cement mortar 1:4 using waterproofing compound at one killogramme per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment of 6 to 8 milimetre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days, scaffolding, excetra complete. (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 11 / 209 Specification No : As per Item No 17 Spec. Page No : --- Additional Specifications : As per Item No 17

330.98

688

227796.99

... More
Providing and fixing frame with / without ventilator of size as specified with country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300 milimetre X 40 milimetre X 5 milimetre with oil painting, excetra complete. (For First Floor) Item / Page No : 1 / 245 Additional Specifications : The work shall be done as per instructions of Engineer in charge.

0.54

211852

114400.59

... More
Providing and fixing country cut teak wood single leaf panelled door shutter without fanlight and 25 milimetre thick as per drawing consisting of teak wood top rail size 100 milimetre X 25 milimetre and bottom rail and lock rail 200 milimetre X 25 milimetre insert panel 12 milimetre thick commercial plyfaced teak wood partical board with phenol formaldehyde synthetic resin (Generally confrming to Indian Standard : 3097) excluding frame inclduding stainless steel fixture and fastening and teak wood beading to junctions of panelled inserts and as instructred by the Engineer in charge including three coats of oil painting, excetra complete. (For First Floor) Item / Page No : 5 / 245 Additional Specifications : 1. The work shall be done as per instructions of Engineer in charge. 2. Door shutter and fixtures and fastenings shall be got approved by Engineer in-charge.

9.12

6197

56518.92

... More
Providing and fixing M-40 grade thick vibrated pull cast or similar type concrete frame with chamfer confirming to Indian Standard : 6524-1983 having 6 milimetre diameter bars three numbers and stirrups at 250 milimetre center to center and fixing in wall with six numbers of holdfast of 12 milimetre diameter bars 500 milimetre long including primer and oil painting, excetra complete. - Frame size 60 milimetre X 100 milimetre. (For First Floor) Item / Page No : 56 / 257 Additional Specifications : 1. The appropriate mix design shall be got done well in advance from the approved government laboratory and the same shall also be got approved from Engineer in-charge, before starting the work. 2. Cement from the same stock sent for mix design shall be used for concreting work. 3. The minimum cement for reinforced cement concrete / plain concrete to ensure durability / strength shall be as per IS 456-2000 with latest ammendment. If actual cement required / consumed is more than the provision in the IS code / approved mix design, no claim for that shall be entertained and cost for that shall be bourned by the contractor. 4. Before concreting work, cement from each consignment shall be got tested and if the strength of cement varies considerably from the approved mix design, the mix design should be got modified according to strength of fresh cement available in stock and concreting work should be done according to modified mix design. 5. For every consignment of cement, a sample shall be got tested as per norms and frequency of Vigilance and Quality Control Circle, Pune. As regards testing of cement it will be entire responsibility of the contractor.

34.2

1128

38608.38

... More
Providing and fixing 30 milimetre thick polyvinyl chloride flush L door shutter consisting of panel of hollow polyvinyl chloride profile of 20 milimetre thickness consisting frame made out of mild steel tubes of 19 gauge thickness and size of 19 milimetre X 19 milimetre inserted inside the hollow section of stiles rails top and bottom rails and two 19 milimetre X 19 milimetre mild steel tubes inserted horizontally inside the hollow profile section using 4/5 milimetre sheet using screws hollow profile shall be lipped with 10 milimetre (5 milimetre X 2) thick X 20 milimetre width on stiles and rails using solvent cement. The inner panel shall be laminated with 5 milimetre thick termite proof waterproof plain / prelam poly vinyl chloride sheet using solvent cement on the both sides of the panel including stainless steel fixtures and fastening excetra Complete as per direction of Engineer in-charge, manufacturer’s specification and drawing. (For First Floor) Item / Page No : 82 / 262 Additional Specifications : The work shall be done as per instructions of Engineer in charge.

6.84

6934

47430.95

... More
Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 milimetre to 605 milimetre X 590 milimetre to 605 milimetre of 8 milimetre to 10 milimetre thickness and confirming to Indian Standard 15622-2006 (Group BIa) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning, excetra complete. (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 40 / 217 Specification No : As per Item No 19 Spec. Page No : --- Additional Specifications : As per Item No 19

140.06

1269

177869.2

... More
Providing and laying vitrified mirror / glossy finish tiles having size 590 milimetre to 605 milimetre X 590 milimetre to 605 milimetre of 8 milimetre to 10 milimetre thickness and confirming to Indian Standard 15622-2006 (Group BIa) of approved make, shade and pattern for dado and skirting in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning, excetra complete. (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 41 / 217 Specification No : As per Item No 20 Spec. Page No : --- Additional Specifications : As per Item No 20

10.63

1349

14344.12

... More
Providing and laying matt finish ceramic tiles of having sizes 30 centimetre X 30 centimetre and confirming to Indian Standard 15622 : 2006 (Group DII-A) and 7 milimetre to 8 milimetre thick for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with white / colour cement slurry, cleaning, curing, excetra complete. (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 24 / 215 Specification No : Bd.M.12 Spec. Page No : 385 Additional Specifications : 1. The work shall be carried out as per direction of Engineer in-charge. 2. The work shall be carried out as per the sample approved from the Deputy Chief Architect, Public Works Deparment, Pune Region, Pune and kept in the office of the Executive Engineer. 3. The tiles should be of reputed approved brand. 4. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

19.8

1275

25249.95

... More
Providing and laying ceramic tiles of having sizes 30 centimetre X 30 centimetre and confirming to corrosponding Indian standared for dado and skirting in required position with ready made adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white / colour cement slurry, cleanding, curing, excetra complete. (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 25 / 215 Specification No : Bd.M.13 Spec. Page No : 386 Additional Specifications : 1. The work shall be carried out as per direction of Engineer in-charge. 2. The work shall be carried out as per the sample approved from the Deputy Chief Architect, Public Works Deparment, Pune Region, Pune and kept in the office of the Executive Engineer. 3. The tiles should be of reputed approved brand. 4. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

82.98

1352

112234.6

... More
Providing and laying damp proof course 50 milimetre thick in M-20 cement concrete layer and bitumen / using cement with waterproofing compound curing, formwork, excetra complete. (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 1 / 205 Specification No : Bd.J.2 Spec. Page No : 355 Additional Specifications : 1. The appropriate mix design shall be got done well in advance from the approved government laboratory and the same shall also be got approved from Engineer in-charge, before starting the work. 2. Cement from the same stock sent for mix design shall be used for concreting work. 3. The minimum cement for reinforced cement concrete / plain concrete to ensure durability / strength shall be as per IS 456-2000 with latest ammendment. If actual cement required / consumed is more than the provision in the IS code / approved mix design, no claim for that shall be entertained and cost for that shall be bourned by the contractor. 4. Before concreting work, cement from each consignment shall be got tested and if the strength of cement varies considerably from the approved mix design, the mix design should be got modified according to strength of fresh cement available in stock and concreting work should be done according to modified mix design. 5. For every consignment of cement, a sample shall be got tested as per norms and frequency of Vigilance and Quality Control Circle, Pune. As regards testing of cement it will be entire responsibility of the contractor. 6. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

30

498

14967

... More
Providing and fixing 15 milimetre diameter screw down bib / stop tap of brass including necessary socket union nut complete. (For First Floor) Item / Page No : 40 / 270 Specification No : Bd.V.8 Spec. Page No : 554

6

710

4263.6

... More
Providing, laying and fixing polyvinyl chloride pipe of 15 milimetre diameter with fittings, such as bends, tees, reducers, clamps, excetra including necessary excavation, trench filling, excetra complete.Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed excetra complete. Item / Page No : 21 / 276 Additional Specifications : 1. The work shall be done as per instructions of Engineer in charge. 2. The P.V.C. Pipe should be of approved and standard brand.

60

86

5160

... More
Providing, laying and fixing polyvinyl chloride pipe of 20 milimetre diameter with fittings such as bends, tees, reducers, clamps, excetra including necessary excavation, trench filling, excetra complete.Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed excetra complete. Item / Page No : 22 / 276 Additional Specifications : 1. The work shall be done as per instructions of Engineer in charge. 2. The P.V.C. Pipe should be of approved and standard brand.

70

132

9250.5

... More
Providing, laying and fixing polyvinyl chloride pipe of 32 milimetre diameter with fittings, such as bends, tees, reducers, clamps, excetra including necessary excavation, trench filling, excetra complete.Including removing existing pipe line if necessary and conveying and stacking thesame in PWD chowky or as directed excetra complete. Item / Page No : 24 / 276 Additional Specifications : 1. The work shall be done as per instructions of Engineer in charge. 2. The P.V.C. Pipe should be of approved and standard brand.

20

237

4741

... More
Providing, laying and fixing polyvinyl chloride pipe of 50 milimetre diameter with fittings such as bends, tees, reducers, clamps, excetra including necessary excavation, trench filling, excetra complete.Including removing existing pipe line if necessary and conveying and stacking thesame in PWD chowky or as directed excetra complete. Item / Page No : 26 / 276 Additional Specifications : 1. The work shall be done as per instructions of Engineer in charge. 2. The P.V.C. Pipe should be of approved and standard brand.

10

442

4427

... More
Providing and fixing Orissa type white glazed earrthenware 575 milimetre water closet pan including "S" trap with earthenware foot rests, cast iron soil and vent pipe upto outside face of the wall, 1:2:4 brick bat lime concrete bedding without flushing tank and its accessories excetra complete. (For First Floor) Item / Page No : 30 / 277 Additional Specifications : The work shall be done as per instructions of Engineer in charge.

2

4243

8486.8

... More
Providing and fixing European type white glazed earthenware water closet pan with unplasticized poly vinyl chloride seat and lid with chromium plated brass hinges and rubber buffers including unplasticized poly vinyl chloride vent pipe up to the outside face of wall, without flushing cistern with flush cock and with water jet and necessary fitting including cutting and making good to the walls and floors, testing, excetra complete.(prior approval of sample and brand by Ex. Engineer is necessary before use) (For First Floor) Item / Page No : 20 / 289 Additional Specifications : 1. Prior approval of sample and brand by Executive Engineer is necessary before use. 2. The work shall be carried out as per instructions of Engineer in charge.

4

11403

45613.2

... More
Provoding and fixing high density polyethylen container one piece moulded water tank made out of high density polyethylen and built corrugated inclusive of delivery upto destination housting, fixing of accessaries such as inlet, outlet, overflow pipe inclusive of all Taxes. Capacity between 200 litres to 1000 litres. (For First Floor) Item / Page No : 53 / 280 Additional Specifications : The work shall be done as per instructions of Engineer in charge.

1000

14

14850

... More
Providing and fixing machine cut machine polished 18 milimetre to 20 milimetre thick telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone for treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on a bed of 1:4 cement mortar including float, filling joints with neat cement slurry, curing, polishing and cleaning, excetra complete. (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 35 / 216 Specification No : As per Item No 18 Spec. Page No : --- Additional Specifications : As per Item No 18

1.08

4427

4781.97

... More
Providing and applying plastic emulsion paint of approved quality, colour and shade to old surface in three coats including scaffolding, preparing the surface (excluding primer coat), excetra complete. (For First Floor) Item / Page No : 13 / 228 Specification No : Bd.P.6 Spec. Page No : 414 Additional Specifications : 1. The priming coat should be applied and got approved from Engineer in-charge. 2. The shade of paints shall be got approved by the Engineer in-charge before use. 3. The paints shall be of Indian Standards and from approved manufactures. The paints shall be got approved before use.

10

105

1059

... More
Providing and applying two coats of exterior weather shield paint of approved manufacturer and of approved colour to the plastered surfaces including cleaning, preparing the plaster surfaces, applying primer coat, scaffolding, if necessary and watering the surface for two days, excetra complete. (For First Floor) Item / Page No : 26 / 225 Specification No : As per Item No 25 Spec. Page No : --- Additional Specifications : As per Item No 25

10

312

3124

... More
Providing and laying cast in situ / Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, compaction, roughening if special finish is to be provided and curing excetra completet (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For 2nd Floor) (using ARTIFICIAL SAND). Item / Page No : 33 / 180 Specification No : As per Item No 5 Spec. Page No : --- Additional Specifications : As per Item No 5

3.32

15510

51495.03

... More
Providing and fixing in position thermo mechnically treated FE-500 steel bar reinforcement of various dias for reinforced cement concrete pile caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardis, copings, fins, arches, excetra as per detailed designs, drawings and schedules including cutting, bendding, hooking the bars, binding with wires or tack welding and supporting as requied complete. (For 2nd Floor) Item / Page No : 33 / 188 Specification No : As per Item No 15 Spec. Page No : --- Additional Specifications : As per Item No 15

0.4

96042

38225.07

... More
Providing second class Burnt Brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 superstructure including striking joints, racking out joints, watering and scaffolding, excetra complete. (For 2nd Floor) (using ARTIFICIAL SAND). Item / Page No : 5 / 197 Specification No : As per Item No 10 Spec. Page No : --- Additional Specifications : As per Item No 10

13.95

9201

128360.23

... More
Providing internal cement plaster 20 milimetre thick in single coat in cement mortar 1:3 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing, excetra complete. (For 2nd Floor) (using ARTIFICIAL SAND). Item / Page No : 8 / 209 Specification No : As per Item No 16 Spec. Page No : --- Additional Specifications : As per Item No 16

103.31

429

44330.32

... More
Providing sand faced plaster externally in cement mortar using approved screened sand in all positions including base coat of 15 milimetre thick in cement mortar 1:4 using waterproofing compound at one killogramme per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment of 6 to 8 milimetre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days, scaffolding, excetra complete. (For 2nd Floor) (using ARTIFICIAL SAND). Item / Page No : 11 / 209 Specification No : As per Item No 17 Spec. Page No : --- Additional Specifications : As per Item No 17

115.15

694

79983.19

... More
Providing and fabricting structural steel work in rolled sections like joists, channels, angles, tees, excetra as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted / welded connections without connecting plates, braces, excetra and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade, excetra complete. (For 2nd Floor) Item / Page No : 1 / 173 Specification No : Bd.C.2 Spec. Page No : 275

0.01

109021

763.15

... More
Providing and fixing of colour coated zincalume (R) AZ 150 (Minimum 150 grams per square metre total on each sides) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 milimetre base metal thickness (BMT) (0.5 milimetre TCT), Hi-strength steel with minium 550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55 percent aluminium, 43.4 percent zinc, 1.6 percent silicon) with COLORBOND (R) steel quality super durable polyster paint coat (with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nominal 950-1050 milimetre effective cover width and nominal 25-30 milimetre deep ribs with subtle square fluting in the five pan at nominal 180-250 milimetre center to centre. The end rib shall be designed for anti capilary groove and return leg. The feed material should have coil manufacturer's product details marked at regular interval. Including fasteners with minium fatened with minium 25 um zinc-tin alloy coated, hex head, self-drilling screw, excetra complete. (Weight of profile 4.52 kilogram per square metre). (For 2nd Floor) Item / Page No : 34 / 236 Additional Specifications : The work shall be done as per instructions of Engineer in charge.

15

1253

18809.25

... More
Providing and fixing mild steel grill work for windows, ventilator, excetra 20 kilogram per square metre as per drawings including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting, excetra complete. (For 2nd Floor) Item / Page No : 1 / 264 Specification No : As per Item No 37 Spec. Page No : --- Additional Specifications : As per Item No 37

1.44

2244

3232.73

... More
Providing and fixing in position (as per Indian Standard : 1868/1982) aluminium sliding window of two tracks with rectangular pipe having overall dimentsions 63.50 milimetre X 38.10 milimetre X 1.02 milimetre at weight 0.547 kilogram per running metre and window frame bottom track section 61.85 milimetre X 31.75 milimetre X 1.20 milimetre at weight 0.695 kilogram per running metre. Top and side track section 61.85 milimetre X 31.75 milimetre X 1.30 milimetre at weight 0.659 kilogram per running metre. The shutter should be of bearing bottom 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre. Interlocking secion 40 milimetre X 18 milimetre X 1.10 milimetre at weight 0.469 kilogram per running metre and handle section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre and top section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre as per detailed drawing and as directed by Engineer in-charge with all necessary aluminium sections, fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 milimetre thick plain glass with all required screws and nuts excetra complete. - With powder coating without box. (For 2nd Floor) Item / Page No : 40 / 252 Specification No : As per Item No 38 Spec. Page No : --- Additional Specifications : As per Item No 38

1.44

5199

7487.42

... More
Providing and fixing M-40 grade thick vibrated pull cast or similar type concrete frame with chamfer confirming to Indian Standard : 6524-1983 having 6 milimetre diameter bars three numbers and stirrups at 250 milimetre center to center and fixing in wall with six numbers of holdfast of 12 milimetre diameter bars 500 milimetre long including primer and oil painting, excetra complete. - Frame size 60 milimetre X 100 milimetre. (For 2nd Floor) Item / Page No : 56 / 257 Specification No : As per Item No 44 Spec. Page No : --- Additional Specifications : As per Item No 44

6

1139

6837.3

... More
Providing and fixing 30 milimetre thick polyvinyl chloride flush L door shutter consisting of panel of hollow polyvinyl chloride profile of 20 milimetre thickness consisting frame made out of mild steel tubes of 19 gauge thickness and size of 19 milimetre X 19 milimetre inserted inside the hollow section of stiles rails top and bottom rails and two 19 milimetre X 19 milimetre mild steel tubes inserted horizontally inside the hollow profile section using 4/5 milimetre sheet using screws hollow profile shall be lipped with 10 milimetre (5 milimetre X 2) thick X 20 milimetre width on stiles and rails using solvent cement. The inner panel shall be laminated with 5 milimetre thick termite proof waterproof plain / prelam poly vinyl chloride sheet using solvent cement on the both sides of the panel including stainless steel fixtures and fastening excetra Complete as per direction of Engineer in-charge, manufacturer’s specification and drawing. (For 2nd Floor) Item / Page No : 82 / 262 Specification No : As per Item No 45 Spec. Page No : --- Additional Specifications : As per Item No 45

1.52

6999

10639.7

... More
Royalty charges for various building construction bonafied materials which are used for government bonafied works and for which Royalty charges are to be paid by the contractor. (This Item is to be paid to the contractor only after he pays the Royalty amount to Revenue department and produces the required voucher.) Item / Page No : 3 / 0 Additional Specifications : 1. Government of Maharashtra, Revenue and Forest Department Gazette Number 146 Dated 04/06/2021 and Government of Maharashtra Public Works Department State Schedule of Rates 2021-22 General Note Number A(v), Page 5. 2. The amount of royalty charges will be paid only after submission of the receipt in original from Revenue authority for payment of royalty to Government, stating the name of work. 3. Above / below percentage quoted by the contractor will not be applicable for this item.

173.71

216

37552.63

... More
Laboratory testing charges for various materials required for items of work, on the basis of testing frequency and charges fixed by Vigilence and Quality Control Circle, Pune. Item / Page No : 4 / 0 Additional Specifications : 1. The amount of the laboratory testing charges will be paid to the contractor after submission of the original receipt from the Office of the Vigilance and Quality Control with name of work mensioned on the original receipt within the stipulated period of work. 2. The frequency of tests will be as per the instructions of Vigilance and Quality Control, Pune; vide their letter No. Prasha/2647/ 2010 dated 30/10/2010. 3. No extra claim shall be entertained on account of additional tests required and material transportation charges for tests. 4. In addition to above, the conditions under clause 25 - Samples and Testing of Material, under 'Additional General Conditions and Specifications' of this tender document shall be applicable. 5. Above / below percentage quoted by the contractor will not be applicable for this item.Crushing Value / Compressive Strength, Water Absorption, Specific Gravity Test for Stone / Rubble 1 Test per Source

1

56780

56780

... More
Add Insurance-1.00% Non-Dsr Item Additional Specifications : The work shall be carried out as per the instructions of Engineer in-charge.

1

113131

113131.23

... More
Add G.S.T-18.00% Non-Dsr Item Additional Specifications : The work shall be carried out as per the instructions of Engineer in-charge.

1

2053342

2053342



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.