Rural Development Department Tender

... More
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Rural Development Department - RDD Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date21 May 2025
Closing Date14 Jun 2025
Tender Amount₹ 2,09,97,480 
Notes
Download

AI Insights

Bid Capacity
... View More
The formula for bid capacity is: Assessed Available Bid Capacity = (A x N x 2) - B or Assessed Available Bid Capacity = (A x N x 1.50) – B, where A = Maximum value of Engineering works executed in anyone year during the last Five years, N = Number of Years prescribed for completion of the works for which bids are invited, and B = Value of existing commitments and on-going works to be completed during the next period or 18 months.
Technical Capacity
... View More
The required prior work experience for the bidder includes having completed civil engineering works in the last three to five years. The bidder should have a minimum of 75% of the tender amount in terms of similar work experience in the last 5 years. The value of similar works completed should be at least 75% of the tender amount. Additionally, the bidder should have executed in any one year, in the last five years, a minimum quantity of work that is approximately 30% of the tendered quantity. The bidder's experience is also considered in terms of the number of years prescribed for completion of the work. The bidder must provide details of works executed in the interior, backward, and hilly areas during the preceding 5 years, if applicable. The bidder should have completed similar type of work and magnitude of the carried out by the contractor. The bidder must also provide a statement showing the work done in all classes of civil engineering construction works during the last five years. The bid capacity is calculated based on the highest amount of work done in any one year out of the last five years (amount "A") and the total cost of work in hand (amount "B"). The bid capacity is calculated as (A*N*1.5)-B or (A*N*2)-B, where N is a multiplying factor for updating. The bidder should have experience in works costing more than 1.00 Cr (estimated cost put to tender, i.e., work portion + testing + royalty charges). The bidder should also submit details of similar type of work and magnitude carried out by the contractor. The key personnel required for the project include a Project In-charge with a minimum of 10 years of experience, a Resident Engineer with a minimum of 5 years of experience, a Site Supervisor with a minimum of 2 years of experience, and a Plant/SCADA system supervisor with a minimum of 2 years of experience. The bidder should also submit a list of technical personnel on the rolls of the tenderer, along with their qualifications and experience. The value of similar works completed is approximately 30% of the tendered quantity. The percentage of similar works completed is also approximately 30% of the tendered quantity.

Costs

  • EMD

    ₹ 2,09,975
  • Document Cost

    ₹ 10,000
  • Tender Fee

    ₹ 500

Summary

Constructing Prasadalaya With Sanitary Unit Ladies And Gents And Bhakta Niwas At Datt Mandir Morve Tal. Khandala Dist Satara

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing and laying Cast in situ/Ready Mix, cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailling out water, formwork, laying/ pumping, compacting and curing, excetra complete, with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed, excetra) (using ARTIFICIAL SAND). Item / Page No : 1 / 175 Specification No : Bd.E.1 Spec. Page No : 287-288 Additional Specifications : 1. The appropriate mix design shall be got done well in advance from the approved government laboratory and the same shall also be got approved from Engineer in-charge, before starting the work. 2. Cement from the same stock sent for mix design shall be used for concreting work. 3. The minimum cement for reinforced cement concrete / plain concrete to ensure durability / strength shall be as per IS 456-2000 with latest ammendment. If actual cement required / consumed is more than the provision in the IS code / approved mix design, no claim for that shall be entertained and cost for that shall be bourned by the contractor. 4. Before concreting work, cement from each consignment shall be got tested and if the strength of cement varies considerably from the approved mix design, the mix design should be got modified according to strength of fresh cement available in stock and concreting work should be done according to modified mix design. 5. For every consignment of cement, a sample shall be got tested as per norms and frequency of Vigilance and Quality Control Circle, Pune. As regards testing of cement it will be entire responsibility of the contractor. 6. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

49.46

6978

-

... More
Providing and laying Cast in situ / Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete work in foundations like raft, strip foundations, grillage and footings of reinforced cement concrete columns and steel stanchions, excetra including bailling out water, formwork, cover blocks, compaction, curing and roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel), excetra complete, with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. with fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (using ARTIFICIAL SAND). Item / Page No : 13 / 178 Specification No : Bd.F.3, B-7 Spec. Page No : 298, 38-40 Additional Specifications : 1. The appropriate mix design shall be got done well in advance from the approved government laboratory and the same shall also be got approved from Engineer in-charge, before starting the work. 2. Cement from the same stock sent for mix design shall be used for concreting work. 3. The minimum cement for reinforced cement concrete / plain concrete to ensure durability / strength shall be as per IS 456-2000 with latest ammendment. If actual cement required / consumed is more than the provision in the IS code / approved mix design, no claim for that shall be entertained and cost for that shall be bourned by the contractor. 4. Before concreting work, cement from each consignment shall be got tested and if the strength of cement varies considerably from the approved mix design, the mix design should be got modified according to strength of fresh cement available in stock and concreting work should be done according to modified mix design. 5. For every consignment of cement, a sample shall be got tested as per norms and frequency of Vigilance and Quality Control Circle, Pune. As regards testing of cement it will be entire responsibility of the contractor. 6. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

48.56

8549

-

... More
Providing and laying cast in situ / Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, compaction, roughening if special finish is to be provided and curing excetra completet (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 33 / 180 Specification No : Bd.F.5, B-7 Spec. Page No : 300, 38-40 Additional Specifications : 1. The appropriate mix design shall be got done well in advance from the approved government laboratory and the same shall also be got approved from Engineer in-charge, before starting the work. 2. Cement from the same stock sent for mix design shall be used for concreting work. 3. The minimum cement for reinforced cement concrete / plain concrete to ensure durability / strength shall be as per IS 456-2000 with latest ammendment. If actual cement required / consumed is more than the provision in the IS code / approved mix design, no claim for that shall be entertained and cost for that shall be bourned by the contractor. 4. Before concreting work, cement from each consignment shall be got tested and if the strength of cement varies considerably from the approved mix design, the mix design should be got modified according to strength of fresh cement available in stock and concreting work should be done according to modified mix design. 5. For every consignment of cement, a sample shall be got tested as per norms and frequency of Vigilance and Quality Control Circle, Pune. As regards testing of cement it will be entire responsibility of the contractor. 6. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

24.25

15883

-

... More
Providing and laying cast in situ / Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, compaction, roughening if special finish is to be provided and curing excetra completet (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 33 / 180 Specification No : As per Item No 6a Spec. Page No : --- Additional Specifications : As per Item No 6a

14.31

16022

-

... More
Providing and laying cast in situ / Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, compaction, roughening if special finish is to be provided and curing excetra completet (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For 2nd Floor) (using ARTIFICIAL SAND). Item / Page No : 33 / 180 Specification No : As per Item No 6a Spec. Page No : --- Additional Specifications : As per Item No 6a

14.31

16160

-

... More
Providing second class burnt brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 in foundations and plinth of inner walls / in plinth of external walls including bailling out water manually, striking joints, on unexposed faces, racking out joints on exposed faces and watering, excetra complete. (using ARTIFICIAL SAND). Item / Page No : 1 / 197 Specification No : Bd.G.1 Spec. Page No : 313 Additional Specifications : 1. The brick shall be got tested before use, from the Government laboratory at the rate of one batch of 15 bricks for every 50000 bricks or part therof at the contractors cost for the following. A) Crushing strength:- i. Dry condition 5 bricks ii. Wet condition 5 bricks B) Water aborption 5 bricks 2. In addition, bricks shall be tested for size, shape and soundness. 3. The proportion of cement mortar shall be 1:6. 4. Minimum two drums of water shall be provided to masons for soaking of bricks at each place where masons are working. 5. For mixing of mortar steel forms of required size only shall be used For mixing of mortar, steel tough or back platform shall be used. 6. The brick work shall be cured for a minimum period of 14 days. 7. The joints on both faces shall be raked to a depth of not less than the thickness of joints for affording good bond plaster. 8. Hold fast of door or window frames shall be embedded in cast in situ 1:2:4 cement concrete blocks of required size without any extra cost. 9. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

25.13

9023

-

... More
Filling in plinth and floors with approved excavated materials in 15 centimetre to 20 centimetre layers including watering and compacting, excetra complete. Item / Page No : 36 / 157 Specification No : Bd.A.10 Spec. Page No : 262-263

111.37

131

-

... More
Filling in plinth and floors with contractors material / brought from outside and approved by Engineer In-Charge, in 15 centimetre to 20 centimetre layers including watering and compaction, excetra complete. Item / Page No : 37 / 157 Specification No : Bd.A.11 Spec. Page No : 263-264

195

861

-

... More
Providing and laying cast in situ /Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks,laying/pumping, compaction and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete.With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 52 / 181 Specification No : Bd.F.6, B-7 Spec. Page No : 300-301, 38-40 Additional Specifications : 1. The appropriate mix design shall be got done well in advance from the approved government laboratory and the same shall also be got approved from Engineer in-charge, before starting the work. 2. Cement from the same stock sent for mix design shall be used for concreting work. 3. The minimum cement for reinforced cement concrete / plain concrete to ensure durability / strength shall be as per IS 456-2000 with latest ammendment. If actual cement required / consumed is more than the provision in the IS code / approved mix design, no claim for that shall be entertained and cost for that shall be bourned by the contractor. 4. Before concreting work, cement from each consignment shall be got tested and if the strength of cement varies considerably from the approved mix design, the mix design should be got modified according to strength of fresh cement available in stock and concreting work should be done according to modified mix design. 5. For every consignment of cement, a sample shall be got tested as per norms and frequency of Vigilance and Quality Control Circle, Pune. As regards testing of cement it will be entire responsibility of the contractor. 6. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

42.21

14220

-

... More
Providing and laying cast in situ /Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks,laying/pumping, compaction and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete.With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 52 / 181 Specification No : As per Item No 10a Spec. Page No : --- Additional Specifications : As per Item No 10a

23.61

14343

-

... More
Providing and laying cast in situ /Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks,laying/pumping, compaction and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete.With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For 2nd Floor) (using ARTIFICIAL SAND). Item / Page No : 52 / 181 Specification No : As per Item No 10a Spec. Page No : --- Additional Specifications : As per Item No 10a

20.83

14467

-

... More
Providing and laying cast in situ / Ready Mix cement concrete M-25 of trap metal for reinforced cement concrete chajja as per detailed design and drawings including centering, formwork, cover blocks, compacting, finishing and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate natural sand/V.S.I. quality Artificial Sand (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 7 / 184 Specification No : BDF-9, B-7 Spec. Page No : 303-304, 38-40 Additional Specifications : 1. The appropriate mix design shall be got done well in advance from the approved government laboratory and the same shall also be got approved from Engineer in-charge, before starting the work. 2. Cement from the same stock sent for mix design shall be used for concreting work. 3. The minimum cement for reinforced cement concrete / plain concrete to ensure durability / strength shall be as per IS 456-2000 with latest ammendment. If actual cement required / consumed is more than the provision in the IS code / approved mix design, no claim for that shall be entertained and cost for that shall be bourned by the contractor. 4. Before concreting work, cement from each consignment shall be got tested and if the strength of cement varies considerably from the approved mix design, the mix design should be got modified according to strength of fresh cement available in stock and concreting work should be done according to modified mix design. 5. For every consignment of cement, a sample shall be got tested as per norms and frequency of Vigilance and Quality Control Circle, Pune. As regards testing of cement it will be entire responsibility of the contractor. 6. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

0.47

16047

-

... More
Providing and laying cast in situ / Ready Mix cement concrete M-25 of trap metal for reinforced cement concrete chajja as per detailed design and drawings including centering, formwork, cover blocks, compacting, finishing and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate natural sand/V.S.I. quality Artificial Sand (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 7 / 184 Specification No : As per Item No 11a Spec. Page No : --- Additional Specifications : As per Item No 11a

0.57

16187

-

... More
Providing and laying cast in situ / Ready Mix cement concrete M-25 of trap metal for reinforced cement concrete chajja as per detailed design and drawings including centering, formwork, cover blocks, compacting, finishing and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate natural sand/V.S.I. quality Artificial Sand (For 2nd Floor) (using ARTIFICIAL SAND). Item / Page No : 7 / 184 Specification No : As per Item No 11a Spec. Page No : --- Additional Specifications : As per Item No 11a

0.55

16327

-

... More
Providing and laying cast in situ / Ready Mix cement concrete M-25 of Trap / granite /quartzite/ gneissmetal for reinforced cement concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 72 / 182 Specification No : Bd.F.8, B-7 Spec. Page No : 302-303, 38-40 Additional Specifications : 1. The appropriate mix design shall be got done well in advance from the approved government laboratory and the same shall also be got approved from Engineer in-charge, before starting the work. 2. Cement from the same stock sent for mix design shall be used for concreting work. 3. The minimum cement for reinforced cement concrete / plain concrete to ensure durability / strength shall be as per IS 456-2000 with latest ammendment. If actual cement required / consumed is more than the provision in the IS code / approved mix design, no claim for that shall be entertained and cost for that shall be bourned by the contractor. 4. Before concreting work, cement from each consignment shall be got tested and if the strength of cement varies considerably from the approved mix design, the mix design should be got modified according to strength of fresh cement available in stock and concreting work should be done according to modified mix design. 5. For every consignment of cement, a sample shall be got tested as per norms and frequency of Vigilance and Quality Control Circle, Pune. As regards testing of cement it will be entire responsibility of the contractor. 6. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

58.77

16047

-

... More
Providing and laying cast in situ / Ready Mix cement concrete M-25 of Trap / granite /quartzite/ gneissmetal for reinforced cement concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 72 / 182 Specification No : As per Item No 12a Spec. Page No : --- Additional Specifications : As per Item No 12a

61.13

16187

-

... More
Providing and laying cast in situ / Ready Mix cement concrete M-25 of Trap / granite /quartzite/ gneissmetal for reinforced cement concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For 2nd Floor) (using ARTIFICIAL SAND). Item / Page No : 72 / 182 Specification No : As per Item No 12a Spec. Page No : --- Additional Specifications : As per Item No 12a

59.53

16327

-

... More
Providing and fixing in position thermo mechnically treated FE-500 steel bar reinforcement of various dias for reinforced cement concrete pile caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardis, copings, fins, arches, excetra as per detailed designs, drawings and schedules including cutting, bendding, hooking the bars, binding with wires or tack welding and supporting as requied complete. (For Ground Floor) Item / Page No : 33 / 188 Specification No : Bd.F.17 Spec. Page No : 306 Additional Specifications : 1. Steel to be used must be as per Indian Standard : 1786 (1985) with latest amendments and manufactured by approved and reputed make. 2. Steel to be used must be procured directly from the manufacturers or from authorised agent of main producers. 3. Various diameters of TMT-FE-500 steel bars brought on site of the work shall be got tested category wise and lot wise, as directed by the Engineer In-Charge and minimum 50 percent of testing should be done in the departmental laboratory.

14.38

98716

-

... More
Providing and fixing in position thermo mechnically treated FE-500 steel bar reinforcement of various dias for reinforced cement concrete pile caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardis, copings, fins, arches, excetra as per detailed designs, drawings and schedules including cutting, bendding, hooking the bars, binding with wires or tack welding and supporting as requied complete. (For First Floor) Item / Page No : 33 / 188 Specification No : As per Item No 13a Spec. Page No : --- Additional Specifications : As per Item No 13a

9.91

99613

-

... More
Providing and fixing in position thermo mechnically treated FE-500 steel bar reinforcement of various dias for reinforced cement concrete pile caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardis, copings, fins, arches, excetra as per detailed designs, drawings and schedules including cutting, bendding, hooking the bars, binding with wires or tack welding and supporting as requied complete. (For 2nd Floor) Item / Page No : 33 / 188 Specification No : As per Item No 13a Spec. Page No : --- Additional Specifications : As per Item No 13a

8.78

100510

-

... More
Providing second class Burnt Brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 superstructure including striking joints, racking out joints, watering and scaffolding, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 5 / 197 Specification No : Bd.G.5 Spec. Page No : 315 Additional Specifications : 1. The brick shall be got tested before use, from the Government laboratory at the rate of one batch of 15 bricks for every 50000 bricks or part therof at the contractors cost for the following. A) Crushing strength:- i. Dry condition 5 bricks ii. Wet condition 5 bricks B) Water aborption 5 bricks 2. In addition, bricks shall be tested for size, shape and soundness. 3. The proportion of cement mortar shall be 1:6. 4. Minimum two drums of water shall be provided to masons for soaking of bricks at each place where masons are working. 5. For mixing of mortar steel forms of required size only shall be used For mixing of mortar, steel tough or back platform shall be used. 6. The brick work shall be cured for a minimum period of 14 days. 7. The joints on both faces shall be raked to a depth of not less than the thickness of joints for affording good bond plaster. 8. Hold fast of door or window frames shall be embedded in cast in situ 1:2:4 cement concrete blocks of required size without any extra cost. 9. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

78.39

9286

-

... More
Providing second class Burnt Brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 superstructure including striking joints, racking out joints, watering and scaffolding, excetra complete. (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 5 / 197 Specification No : As per Item No 14a Spec. Page No : --- Additional Specifications : As per Item No 14a

111.84

9366

-

... More
Providing second class Burnt Brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 superstructure including striking joints, racking out joints, watering and scaffolding, excetra complete. (For 2nd Floor) (using ARTIFICIAL SAND). Item / Page No : 5 / 197 Specification No : As per Item No 14a Spec. Page No : --- Additional Specifications : As per Item No 14a

136.7

9446

-

... More
Providing and laying telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone of 18 milimetre to 20 milimetre thick for door frame / dado / window boxing, excetra on cement mortar 1:6 including filling joints with polymer base filler, nosing the sharp edges wherever necessary, curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 68 / 220 Additional Specifications : 1. The work shall be carried out as per the sample approved by the Engineer in-charge and kept in the office of the Executive Engineer. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

35.22

4826

-

... More
Providing and laying telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone of 18 milimetre to 20 milimetre thick for door frame / dado / window boxing, excetra on cement mortar 1:6 including filling joints with polymer base filler, nosing the sharp edges wherever necessary, curing, excetra complete. (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 68 / 220 Specification No : As per Item No 15a Spec. Page No : --- Additional Specifications : As per Item No 15a

37.92

4870

-

... More
Providing and laying telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone of 18 milimetre to 20 milimetre thick for door frame / dado / window boxing, excetra on cement mortar 1:6 including filling joints with polymer base filler, nosing the sharp edges wherever necessary, curing, excetra complete. (For 2nd Floor) (using ARTIFICIAL SAND). Item / Page No : 68 / 220 Specification No : As per Item No 15a Spec. Page No : --- Additional Specifications : As per Item No 15a

35.94

4914

-

... More
Providing and fixing solid core flush door shutter in single leaf 32 milimetre thick decorative type of exterior grade as per detailed drawings, approved face veneers 3 milimetre thick on both faces or as directed, all necessary beeds, moulding and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides and finishing with french polish, excetra complete. (For Ground Floor) Item / Page No : 9 / 246 Specification No : Bd.T.34 Spec. Page No : 499 Additional Specifications : Door shutter and fixtures and fastenings shall be got approved by Engineer in-charge.

16.5

3380

-

... More
Providing and fixing solid core flush door shutter in single leaf 32 milimetre thick decorative type of exterior grade as per detailed drawings, approved face veneers 3 milimetre thick on both faces or as directed, all necessary beeds, moulding and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides and finishing with french polish, excetra complete. (For First Floor) Item / Page No : 9 / 246 Specification No : As per Item No 16a Spec. Page No : --- Additional Specifications : As per Item No 16a

23.58

3411

-

... More
Providing and fixing solid core flush door shutter in single leaf 32 milimetre thick decorative type of exterior grade as per detailed drawings, approved face veneers 3 milimetre thick on both faces or as directed, all necessary beeds, moulding and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides and finishing with french polish, excetra complete. (For 2nd Floor) Item / Page No : 9 / 246 Specification No : As per Item No 16a Spec. Page No : --- Additional Specifications : As per Item No 16a

23.58

3442

-

... More
Providing and fixing mild steel grill work for windows, ventilators, excetra 15 kilogram per square metre as per drawing including fixtures, necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting, excetra complete. (For Ground Floor) Item / Page No : 2 / 264 Specification No : Bd.U.1 Spec. Page No : 537 Additional Specifications : 1. The work shall be done as per instructions of Engineer in charge. 2. The grill design shall be got approved from the Engineer in-charge before use.

45.66

1877

-

... More
Providing and fixing mild steel grill work for windows, ventilators, excetra 15 kilogram per square metre as per drawing including fixtures, necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting, excetra complete. (For First Floor) Item / Page No : 2 / 264 Specification No : As per Item No 17a Spec. Page No : --- Additional Specifications : As per Item No 17a

51

1894

-

... More
Providing and fixing mild steel grill work for windows, ventilators, excetra 15 kilogram per square metre as per drawing including fixtures, necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting, excetra complete. (For 2nd Floor) Item / Page No : 2 / 264 Specification No : As per Item No 17a Spec. Page No : --- Additional Specifications : As per Item No 17a

51

1911

-

... More
Providing and fixing in position (as per Indian Standard : 1868/1982) aluminium sliding window of three tracks with rectangular pipe having overall dimentsions 95 milimetre X 38 milimetre X 0.90 milimetre at weight 0.637 kilogram per running metre and window frame bottom track section 92 milimetre X 31.75 milimetre X 1.30 milimetre at weight 1.070 kilogram per running metre. Top and side track section 92 milimetre X 31.75 milimetre X 1.30 milimetre at weight 0.933 kilogram per running metre. The shutter should be of bearing bottom 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre. Interlocking secion 40 milimetre X 18 milimetre X 1.10 milimetre at weight 0.469 kilogram per running metre and handle section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre and top section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre as per detailed drawing and as directed by Engineer in-charge with all necessary aluminium sections, fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 milimetre thick plain glass and aluminium mosquito net shutter with stainless steel jali with all required screws and nuts excetra complete. - With powder coating without box. (For Ground Floor) Item / Page No : 44 / 254 Additional Specifications : The work shall be done as per instructions of Engineer in charge.

40.8

5454

-

... More
Providing and fixing in position (as per Indian Standard : 1868/1982) aluminium sliding window of three tracks with rectangular pipe having overall dimentsions 95 milimetre X 38 milimetre X 0.90 milimetre at weight 0.637 kilogram per running metre and window frame bottom track section 92 milimetre X 31.75 milimetre X 1.30 milimetre at weight 1.070 kilogram per running metre. Top and side track section 92 milimetre X 31.75 milimetre X 1.30 milimetre at weight 0.933 kilogram per running metre. The shutter should be of bearing bottom 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre. Interlocking secion 40 milimetre X 18 milimetre X 1.10 milimetre at weight 0.469 kilogram per running metre and handle section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre and top section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre as per detailed drawing and as directed by Engineer in-charge with all necessary aluminium sections, fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 milimetre thick plain glass and aluminium mosquito net shutter with stainless steel jali with all required screws and nuts excetra complete. - With powder coating without box. (For First Floor) Item / Page No : 44 / 254 Specification No : As per Item No 18a Spec. Page No : --- Additional Specifications : As per Item No 18a

45.6

5504

-

... More
Providing and fixing in position (as per Indian Standard : 1868/1982) aluminium sliding window of three tracks with rectangular pipe having overall dimentsions 95 milimetre X 38 milimetre X 0.90 milimetre at weight 0.637 kilogram per running metre and window frame bottom track section 92 milimetre X 31.75 milimetre X 1.30 milimetre at weight 1.070 kilogram per running metre. Top and side track section 92 milimetre X 31.75 milimetre X 1.30 milimetre at weight 0.933 kilogram per running metre. The shutter should be of bearing bottom 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre. Interlocking secion 40 milimetre X 18 milimetre X 1.10 milimetre at weight 0.469 kilogram per running metre and handle section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre and top section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre as per detailed drawing and as directed by Engineer in-charge with all necessary aluminium sections, fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 milimetre thick plain glass and aluminium mosquito net shutter with stainless steel jali with all required screws and nuts excetra complete. - With powder coating without box. (For 2nd Floor) Item / Page No : 44 / 254 Specification No : As per Item No 18a Spec. Page No : --- Additional Specifications : As per Item No 18a

43.2

5554

-

... More
Providing and applying two coats of wall care putty on plastered surface and ceiling and walls to prepare surface even and smooth approved make excetra complete. (For Ground Floor) Item / Page No : 34 / 212 Additional Specifications : The work shall be carried out as per instructions of Engineer in charge.

321.84

98

-

... More
Providing and applying two coats of wall care putty on plastered surface and ceiling and walls to prepare surface even and smooth approved make excetra complete. (For First Floor) Item / Page No : 34 / 212 Specification No : As per Item No 19a Spec. Page No : --- Additional Specifications : As per Item No 19a

312.43

99

-

... More
Providing and applying two coats of wall care putty on plastered surface and ceiling and walls to prepare surface even and smooth approved make excetra complete. (For 2nd Floor) Item / Page No : 34 / 212 Specification No : As per Item No 19a Spec. Page No : --- Additional Specifications : As per Item No 19a

312.43

100

-

... More
Providing internal cement plaster 12 milimetre thick in a single coat in cement mortar 1:4 with neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 4 / 209 Specification No : Bd.L.2, Bd.L.10 Spec. Page No : 368, 370 Additional Specifications : 1. The surface to be plastered shall be first cleaned and thoroughly wetted for 24 hours and got checked from Engineer in-charge before starting the work. 2. Item includes rounding of all internal and external junctions, corners, jambs, etc. as directed by the Engineer in-charge. 3. Finishing shall be plain and in line, level and plumb. 4. Curing shall be done by sprinkling water on the surface for minimum period of 14 days. 5. Application of sand faced treatment shall be commenced only after passing the base coat Engineer in-charge. 6. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

625.72

383

-

... More
Providing internal cement plaster 12 milimetre thick in a single coat in cement mortar 1:4 with neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing, excetra complete. (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 4 / 209 Specification No : As per Item No 20a Spec. Page No : --- Additional Specifications : As per Item No 20a

897.41

386

-

... More
Providing internal cement plaster 12 milimetre thick in a single coat in cement mortar 1:4 with neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing, excetra complete. (For 2nd Floor) (using ARTIFICIAL SAND). Item / Page No : 4 / 209 Specification No : As per Item No 20a Spec. Page No : --- Additional Specifications : As per Item No 20a

897.41

389

-

... More
Providing internal cement plaster 20 milimetre thick in single coat in cement mortar 1:4 without neeru finish to concrete, brick surface, in all positions including scaffolding and curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 7 / 209 Specification No : Bd.L.4 Spec. Page No : 368 Additional Specifications : 1. The surface to be plastered shall be first cleaned and thoroughly wetted for 24 hours and got checked from Engineer in-charge before starting the work. 2. Item includes rounding of all internal and external junctions, corners, jambs, etc. as directed by the Engineer in-charge. 3. Finishing shall be plain and in line, level and plumb. 4. Curing shall be done by sprinkling water on the surface for minimum period of 14 days. 5. Application of sand faced treatment shall be commenced only after passing the base coat Engineer in-charge. 6. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

420.18

430

-

... More
Providing internal cement plaster 20 milimetre thick in single coat in cement mortar 1:4 without neeru finish to concrete, brick surface, in all positions including scaffolding and curing, excetra complete. (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 7 / 209 Specification No : As per Item No 21a Spec. Page No : --- Additional Specifications : As per Item No 21a

400.54

433

-

... More
Providing internal cement plaster 20 milimetre thick in single coat in cement mortar 1:4 without neeru finish to concrete, brick surface, in all positions including scaffolding and curing, excetra complete. (For 2nd Floor) (using ARTIFICIAL SAND). Item / Page No : 7 / 209 Specification No : As per Item No 21a Spec. Page No : --- Additional Specifications : As per Item No 21a

400.54

437

-

... More
Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 milimetre to 605 milimetre X 590 milimetre to 605 milimetre of 8 milimetre to 10 milimetre thickness and confirming to Indian Standard 15622-2006 (Group BIa) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 40 / 217 Specification No : Bd.M.12 Spec. Page No : 385 Additional Specifications : 1. The work shall be carried out as per instructions of Engineer in-charge. 2. The work shall be carried out as per the sample approved by the Engineer in-charge and kept in the office of the Executive Engineer. 3. Water absorption should not be more than 0.05 percent. 4. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

273.37

1302

-

... More
Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 milimetre to 605 milimetre X 590 milimetre to 605 milimetre of 8 milimetre to 10 milimetre thickness and confirming to Indian Standard 15622-2006 (Group BIa) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning, excetra complete. (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 40 / 217 Specification No : As per Item No 22a Spec. Page No : --- Additional Specifications : As per Item No 22a

310.81

1314

-

... More
Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 milimetre to 605 milimetre X 590 milimetre to 605 milimetre of 8 milimetre to 10 milimetre thickness and confirming to Indian Standard 15622-2006 (Group BIa) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning, excetra complete. (For 2nd Floor) (using ARTIFICIAL SAND). Item / Page No : 40 / 217 Specification No : As per Item No 22a Spec. Page No : --- Additional Specifications : As per Item No 22a

306.27

1326

-

... More
Providing and fixing machine cut machine polished 18 milimetre to 20 milimetre thick telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone for treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on a bed of 1:4 cement mortar including float, filling joints with neat cement slurry, curing, polishing and cleaning, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 35 / 216 Specification No : Bd.M.22 B Spec. Page No : 390 Additional Specifications : 1. The work shall be carried out as per instructions of Engineer in-charge. 2. The work shall be carried out as per the sample approved by the Engineer in-charge and kept in the office of the Executive Engineer. 3. The edge of step should be chafered or rounded as directed. 4. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

47.99

4592

-

... More
Providing and fixing machine cut machine polished 18 milimetre to 20 milimetre thick telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone for treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on a bed of 1:4 cement mortar including float, filling joints with neat cement slurry, curing, polishing and cleaning, excetra complete. (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 35 / 216 Specification No : As per Item No 23a Spec. Page No : --- Additional Specifications : As per Item No 23a

39.53

4634

-

... More
Providing and fixing machine cut machine polished 18 milimetre to 20 milimetre thick telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone for treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on a bed of 1:4 cement mortar including float, filling joints with neat cement slurry, curing, polishing and cleaning, excetra complete. (For 2nd Floor) (using ARTIFICIAL SAND). Item / Page No : 35 / 216 Specification No : As per Item No 23a Spec. Page No : --- Additional Specifications : As per Item No 23a

39.53

4675

-

... More
Providing and applying interior wall finish luster of approved make on internal wall surface as detailed below scrapping the surface with emery paper and wipe clean wall primer with brush with mineral turpentine with brush 8 to 10 percent and oil 15 to 20 percent with roller and allowing to dry for a period 6 to 8 hours. wall putty with appropriate proportion of water allowing to dry for period 4 to 6 hours. Scrapping with emery paper 180 and wipe clean. Applying wall primer with brush with mineral turpentine 8 to 10 percent and oil 15 to 20 percent with roller. Scrapping emery paper 320 and wipe clean, interior wall finish luster first coat with brush/ rubber/ spray with mineral turpentine 7 to 9 percent and Oil with roller 19 to 21 percent. After 8 hours of activity, applying second coat or wall finish Lustre with mineral turpentine 7 to 9 percent with brush and Oil with roller 19 to 21 percent after allowing dry for the period of 6 to 8 hours activity. (With prior approval of S.E.) (For Ground Floor) Item / Page No : 20 / 228 Additional Specifications : The work shall be done as per instructions of Engineer in charge.

553.73

261

-

... More
Providing and applying interior wall finish luster of approved make on internal wall surface as detailed below scrapping the surface with emery paper and wipe clean wall primer with brush with mineral turpentine with brush 8 to 10 percent and oil 15 to 20 percent with roller and allowing to dry for a period 6 to 8 hours. wall putty with appropriate proportion of water allowing to dry for period 4 to 6 hours. Scrapping with emery paper 180 and wipe clean. Applying wall primer with brush with mineral turpentine 8 to 10 percent and oil 15 to 20 percent with roller. Scrapping emery paper 320 and wipe clean, interior wall finish luster first coat with brush/ rubber/ spray with mineral turpentine 7 to 9 percent and Oil with roller 19 to 21 percent. After 8 hours of activity, applying second coat or wall finish Lustre with mineral turpentine 7 to 9 percent with brush and Oil with roller 19 to 21 percent after allowing dry for the period of 6 to 8 hours activity. (With prior approval of S.E.) (For First Floor) Item / Page No : 20 / 228 Specification No : As per Item No 24a Spec. Page No : --- Additional Specifications : As per Item No 24a

897.41

263

-

... More
Providing and applying interior wall finish luster of approved make on internal wall surface as detailed below scrapping the surface with emery paper and wipe clean wall primer with brush with mineral turpentine with brush 8 to 10 percent and oil 15 to 20 percent with roller and allowing to dry for a period 6 to 8 hours. wall putty with appropriate proportion of water allowing to dry for period 4 to 6 hours. Scrapping with emery paper 180 and wipe clean. Applying wall primer with brush with mineral turpentine 8 to 10 percent and oil 15 to 20 percent with roller. Scrapping emery paper 320 and wipe clean, interior wall finish luster first coat with brush/ rubber/ spray with mineral turpentine 7 to 9 percent and Oil with roller 19 to 21 percent. After 8 hours of activity, applying second coat or wall finish Lustre with mineral turpentine 7 to 9 percent with brush and Oil with roller 19 to 21 percent after allowing dry for the period of 6 to 8 hours activity. (With prior approval of S.E.) (For 2nd Floor) Item / Page No : 20 / 228 Specification No : As per Item No 24a Spec. Page No : --- Additional Specifications : As per Item No 24a

897.41

266

-

... More
Providing and applying two coats of exterior acraylic emulsion paint confirming to corresponding Indian Standard of approved manufacturer and of approved colour to the plastered surfaces including cleaning, preparing the plaster surfaces, applying primer coat, scaffolding, if necessary and watering the surface for two days, excetra complete. (For Ground Floor) Item / Page No : 25 / 225 Additional Specifications : 1. The shade of paints shall be got approved by the Engineer in-charge before use. 2. The paints shall be of Indian Standards and from approved manufactures. The paints shall be got approved before use.

420.18

286

-

... More
Providing and applying two coats of exterior acraylic emulsion paint confirming to corresponding Indian Standard of approved manufacturer and of approved colour to the plastered surfaces including cleaning, preparing the plaster surfaces, applying primer coat, scaffolding, if necessary and watering the surface for two days, excetra complete. (For First Floor) Item / Page No : 25 / 225 Specification No : As per Item No 25a Spec. Page No : --- Additional Specifications : As per Item No 25a

400.54

289

-

... More
Providing and applying two coats of exterior acraylic emulsion paint confirming to corresponding Indian Standard of approved manufacturer and of approved colour to the plastered surfaces including cleaning, preparing the plaster surfaces, applying primer coat, scaffolding, if necessary and watering the surface for two days, excetra complete. (For 2nd Floor) Item / Page No : 25 / 225 Specification No : As per Item No 25a Spec. Page No : --- Additional Specifications : As per Item No 25a

400.54

291

-

... More
Providing and Fixing matt finish stainless steel of 302 grade railing with top pipe of 50 milimetre diameter and vertical pipe of 38 milimetre diameter at 0.60 metre center to center or as required and horizontal pipes of 25 milimetre diameter in three rows, all pipes of 2 milimetre thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 milimetre diameter above newel post of 75 milimetre diameter excetra complete (Prior approval of sample and brand by Ex.Engineer is necessary before use) welding, grinding, finishing, buffing to stainless steel pipe, excetra complete. (For Ground Floor) Item / Page No : 8 / 265 Additional Specifications : The work shall be done as per instructions of Engineer in charge.

2.7

3892

-

... More
Providing and Fixing matt finish stainless steel of 302 grade railing with top pipe of 50 milimetre diameter and vertical pipe of 38 milimetre diameter at 0.60 metre center to center or as required and horizontal pipes of 25 milimetre diameter in three rows, all pipes of 2 milimetre thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 milimetre diameter above newel post of 75 milimetre diameter excetra complete (Prior approval of sample and brand by Ex.Engineer is necessary before use) welding, grinding, finishing, buffing to stainless steel pipe, excetra complete. (For First Floor) Item / Page No : 8 / 265 Specification No : As per Item No 26a Spec. Page No : --- Additional Specifications : As per Item No 26a

2.7

3927

-

... More
Providing and Fixing matt finish stainless steel of 302 grade railing with top pipe of 50 milimetre diameter and vertical pipe of 38 milimetre diameter at 0.60 metre center to center or as required and horizontal pipes of 25 milimetre diameter in three rows, all pipes of 2 milimetre thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 milimetre diameter above newel post of 75 milimetre diameter excetra complete (Prior approval of sample and brand by Ex.Engineer is necessary before use) welding, grinding, finishing, buffing to stainless steel pipe, excetra complete. (For 2nd Floor) Item / Page No : 8 / 265 Specification No : As per Item No 26a Spec. Page No : --- Additional Specifications : As per Item No 26a

2.7

3963

-

... More
Painting letters upto 20 centimetre height complete brushes, coir brushes, dusting, cleaning, including cost of paint, excetra complete. Item / Page No : 5 / 46 Specification No : MORTH-805 Spec. Page No : 243-244

10

31

-

... More
Royalty charges for various building construction bonafied materials which are used for government bonafied works and for which Royalty charges are to be paid by the contractor. (This Item is to be paid to the contractor only after he pays the Royalty amount to Revenue department and produces the required voucher.) Item / Page No : 3 / 0 Additional Specifications : 1. Government of Maharashtra, Revenue and Forest Department Gazette Number 146 Dated 04/06/2021 and Government of Maharashtra Public Works Department State Schedule of Rates 2021-22 General Note Number A(v), Page 5. 2. The amount of royalty charges will be paid only after submission of the receipt in original from Revenue authority for payment of royalty to Government, stating the name of work. 3. Above / below percentage quoted by the contractor will not be applicable for this item.

271.88

216

-

... More
Providing and laying vitrified mirror / glossy finish tiles having size 590 milimetre to 605 milimetre X 590 milimetre to 605 milimetre of 8 milimetre to 10 milimetre thickness and confirming to Indian Standard 15622-2006 (Group BIa) of approved make, shade and pattern for dado and skirting in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 41 / 217 Specification No : Bd.M.12 Spec. Page No : 385 Additional Specifications : 1. The work shall be carried out as per instructions of Engineer in-charge. 2. The work shall be carried out as per the sample approved by the Engineer in-charge and kept in the office of the Executive Engineer. 3. Water absorption should not be more than 0.05 percent. 4. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

10.32

1384

-

... More
Providing and laying vitrified mirror / glossy finish tiles having size 590 milimetre to 605 milimetre X 590 milimetre to 605 milimetre of 8 milimetre to 10 milimetre thickness and confirming to Indian Standard 15622-2006 (Group BIa) of approved make, shade and pattern for dado and skirting in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning, excetra complete. (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 41 / 217 Specification No : As per Item No 29a Spec. Page No : --- Additional Specifications : As per Item No 29a

18.8

1397

-

... More
Providing and laying vitrified mirror / glossy finish tiles having size 590 milimetre to 605 milimetre X 590 milimetre to 605 milimetre of 8 milimetre to 10 milimetre thickness and confirming to Indian Standard 15622-2006 (Group BIa) of approved make, shade and pattern for dado and skirting in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning, excetra complete. (For 2nd Floor) (using ARTIFICIAL SAND). Item / Page No : 41 / 217 Specification No : As per Item No 29a Spec. Page No : --- Additional Specifications : As per Item No 29a

18.8

1410

-

... More
Providing detailed layout plan of area in scale 1:500 including carrying out contour survey and detailed Engineering plane table survey with the help of 24" Alidade. The dolomite area measurement of the plot and structures, trees, over head line and under ground service amenities within the area, with triagular method and giving detailes of the structures, such as total area, type of building and distance from all corners, taking trial pit 0.5 metre X 0.5 metre X 2.00 metre 2 numbers per acre and collection of record from city survey / D.I.L.R. authorities and authentication. The plan shall be traced on 75 micron polyster film and shall be submitted along with three amonia prints. The contour levels shall be marked at 0.5. metre intervals. - up to 1 Acre. Item / Page No : 22 / 15 Additional Specifications : The Work shall be carried out as per the instructions of Engineer In-Charg.

1

9965

-

... More
Providing and laying cement concrete flooring 50 milimetre thick with M-20 cement concrete laid to proper level and slope in alternate bays including compaction, filling joints, marking lines to give the appearance of tiles of 30 centimetre X 30 centimetre or other size laid diagonally / square, excetra, finishing smooth (with extra cement) in any colour as directed and curing complete. - with crushed sand. (For Ground Floor) Item / Page No : 16 / 214 Specification No : Bd.M.6 Spec. Page No : 381 Additional Specifications : 1. The appropriate mix design shall be got done well in advance from the approved government laboratory and the same shall also be got approved from Engineer in-charge, before starting the work. 2. Cement from the same stock sent for mix design shall be used for concreting work. 3. The minimum cement for reinforced cement concrete / plain concrete to ensure durability / strength shall be as per IS 456-2000 with latest ammendment. If actual cement required / consumed is more than the provision in the IS code / approved mix design, no claim for that shall be entertained and cost for that shall be bourned by the contractor. 4. Before concreting work, cement from each consignment shall be got tested and if the strength of cement varies considerably from the approved mix design, the mix design should be got modified according to strength of fresh cement available in stock and concreting work should be done according to modified mix design. 5. For every consignment of cement, a sample shall be got tested as per norms and frequency of Vigilance and Quality Control Circle, Pune. As regards testing of cement it will be entire responsibility of the contractor.

113.66

565

-

... More
Providing and fixing hume pipe septic tank 900 milimetre diameter with vent pipe and cap including excavation and laying. Item / Page No : 18 / 275 Specification No : Bd.V.45 Spec. Page No : 575

4

18585

-

... More
Providing and fixing european type wall hung white water closet of approved make with push valve consealed type with cover plate 32 milimetre size of approved make including soil pipe, vent pipe upto outside face of wall, 100 milimetre diameter galvanised iron plug, bend, inlet pipe all fittings, cutting and making good walls, floors, excetra complete. (For Ground Floor) Item / Page No : 86 / 283 Additional Specifications : The work shall be done as per instructions of Engineer in charge.

9

16498

-

... More
Providing and fixing european type wall hung white water closet of approved make with push valve consealed type with cover plate 32 milimetre size of approved make including soil pipe, vent pipe upto outside face of wall, 100 milimetre diameter galvanised iron plug, bend, inlet pipe all fittings, cutting and making good walls, floors, excetra complete. (For First Floor) Item / Page No : 86 / 283 Specification No : As per Item No 33a Spec. Page No : --- Additional Specifications : As per Item No 33a

10

16648

-

... More
Providing and fixing european type wall hung white water closet of approved make with push valve consealed type with cover plate 32 milimetre size of approved make including soil pipe, vent pipe upto outside face of wall, 100 milimetre diameter galvanised iron plug, bend, inlet pipe all fittings, cutting and making good walls, floors, excetra complete. (For 2nd Floor) Item / Page No : 86 / 283 Specification No : As per Item No 33a Spec. Page No : --- Additional Specifications : As per Item No 33a

10

16799

-

... More
Providing and fixing Orissa type white glazed earrthenware 575 milimetre water closet pan including "S" trap with earthenware foot rests, cast iron soil and vent pipe upto outside face of the wall, 1:2:4 brick bat lime concrete bedding without flushing tank and its accessories excetra complete. (For Ground Floor) Item / Page No : 30 / 277 Additional Specifications : The work shall be done as per instructions of Engineer in charge.

9

4399

-

... More
Providing and laying in trenches 15 milimetre diameter chlorinated poly vinyl chloride pipe including necessary excavation, fittings, refilling trenches, excetra complete Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed excetra complete. Item / Page No : 61 / 280 Specification No : Bd.V.5 Spec. Page No : 551 Additional Specifications : 1. The work shall be done as per instructions of Engineer in charge. 2. The specified diametre of the pipe shall refer to the inside diametre of the pipe and fittings. 3. Screw clips and fittings shall be of standard type to match the pipe.

260

299

-

... More
Providing, laying and fixing polyvinyl chloride pipe of 110 milimetre diameter with fittings such as bends, tees, reducers, clamps, excetra including necessary excavation, trench filling, excetra complete.Including removing existing pipe line if necessary and conveying and stacking thesame in PWD chowky or as directed excetra complete. Item / Page No : 28 / 277 Additional Specifications : 1. The work shall be done as per instructions of Engineer in charge. 2. The P.V.C. Pipe should be of approved and standard brand.

68

652

-

... More
Providing and fixing 30 milimetre thick solid panel polyvinyl chloride internal door shutter consisting of frame made out of mild steel tubes of 19 gauge thickness and size of 40 milimetre X 20 milimetre for stiles, top, lock and bottom rails. Mild steel frame shall have a coat of steel primers of approved make and manufacture. Mild steel frame shall be covered with 5 milimetre thick heat moulded Rajshri polyvinyl chloride 'C' channel of size 30 milimetre X 100 milimetre forming stiles, and 5 milimetre thick, 125 milimetre wide poly vinyl chloride sheets for top rail, lock rail and bottom rail on either side, and 15 milimetre (5 milimetre X 3) thick, 20 milimetre wide cross poly vinyl chloride sheet as gap insert for top rail and bottom rail. Paneling of 10 milimetre thick prelam poly vinyl chloride sheet to be fitted in the mild steel frame welded / sealed to the stiles and rails with 30 milimetre wide X 5 milimetre thick poly vinyl chloride sheet beading on either side, and joined together with solvent cement adhesive, excetra An additional 5 milimetre thick poly vinyl chloride strip of 20 milimetre width is to be stuck on the interior side of the 'C' Channel using polyvinyl chloride solvent cement adhesive, including stainless steel fixtures and fastening Complete as per direction of Engineer-in-charge, manufacturer’s specification and drawing. (For Ground Floor) Item / Page No : 81 / 261 Additional Specifications : The work shall be done as per instructions of Engineer in charge.

28.35

6924

-

... More
Providing and fixing 30 milimetre thick solid panel polyvinyl chloride internal door shutter consisting of frame made out of mild steel tubes of 19 gauge thickness and size of 40 milimetre X 20 milimetre for stiles, top, lock and bottom rails. Mild steel frame shall have a coat of steel primers of approved make and manufacture. Mild steel frame shall be covered with 5 milimetre thick heat moulded Rajshri polyvinyl chloride 'C' channel of size 30 milimetre X 100 milimetre forming stiles, and 5 milimetre thick, 125 milimetre wide poly vinyl chloride sheets for top rail, lock rail and bottom rail on either side, and 15 milimetre (5 milimetre X 3) thick, 20 milimetre wide cross poly vinyl chloride sheet as gap insert for top rail and bottom rail. Paneling of 10 milimetre thick prelam poly vinyl chloride sheet to be fitted in the mild steel frame welded / sealed to the stiles and rails with 30 milimetre wide X 5 milimetre thick poly vinyl chloride sheet beading on either side, and joined together with solvent cement adhesive, excetra An additional 5 milimetre thick poly vinyl chloride strip of 20 milimetre width is to be stuck on the interior side of the 'C' Channel using polyvinyl chloride solvent cement adhesive, including stainless steel fixtures and fastening Complete as per direction of Engineer-in-charge, manufacturer’s specification and drawing. (For First Floor) Item / Page No : 81 / 261 Specification No : As per Item No 37a Spec. Page No : --- Additional Specifications : As per Item No 37a

13.5

6987

-

... More
Providing and fixing 30 milimetre thick solid panel polyvinyl chloride internal door shutter consisting of frame made out of mild steel tubes of 19 gauge thickness and size of 40 milimetre X 20 milimetre for stiles, top, lock and bottom rails. Mild steel frame shall have a coat of steel primers of approved make and manufacture. Mild steel frame shall be covered with 5 milimetre thick heat moulded Rajshri polyvinyl chloride 'C' channel of size 30 milimetre X 100 milimetre forming stiles, and 5 milimetre thick, 125 milimetre wide poly vinyl chloride sheets for top rail, lock rail and bottom rail on either side, and 15 milimetre (5 milimetre X 3) thick, 20 milimetre wide cross poly vinyl chloride sheet as gap insert for top rail and bottom rail. Paneling of 10 milimetre thick prelam poly vinyl chloride sheet to be fitted in the mild steel frame welded / sealed to the stiles and rails with 30 milimetre wide X 5 milimetre thick poly vinyl chloride sheet beading on either side, and joined together with solvent cement adhesive, excetra An additional 5 milimetre thick poly vinyl chloride strip of 20 milimetre width is to be stuck on the interior side of the 'C' Channel using polyvinyl chloride solvent cement adhesive, including stainless steel fixtures and fastening Complete as per direction of Engineer-in-charge, manufacturer’s specification and drawing. (For 2nd Floor) Item / Page No : 81 / 261 Specification No : As per Item No 37a Spec. Page No : --- Additional Specifications : As per Item No 37a

13.5

7050

-

... More
Providing and fixing in position aluminium partly openable and partly fixed window of any size as per detailed drawing and as directed by Engineer in-charge with all necessary aluminium sections including necessary fixtures and fastenings with 5 milimetre thick clear float glass, excetra complete. - With colour anodizing (For Ground Floor) Item / Page No : 54 / 257 Additional Specifications : 1. The work shall be done as per instructions of Engineer in charge. 2. Weight of aluminium section must be 6.90 kilogram per square metre.

2.43

6963

-

... More
Providing and fixing in position aluminium partly openable and partly fixed window of any size as per detailed drawing and as directed by Engineer in-charge with all necessary aluminium sections including necessary fixtures and fastenings with 5 milimetre thick clear float glass, excetra complete. - With colour anodizing (For First Floor) Item / Page No : 54 / 257 Specification No : As per Item No 38a Spec. Page No : --- Additional Specifications : As per Item No 38a

5.4

7026

-

... More
Providing and laying matt finish ceramic tiles of having sizes 30 centimetre X 30 centimetre and confirming to Indian Standard 15622 : 2006 (Group DII-A) and 7 milimetre to 8 milimetre thick for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with white / colour cement slurry, cleaning, curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 24 / 215 Specification No : Bd.M.12 Spec. Page No : 385 Additional Specifications : 1. The work shall be carried out as per direction of Engineer in-charge. 2. The work shall be carried out as per the sample approved from the Deputy Chief Architect, Public Works Deparment, Pune Region, Pune and kept in the office of the Executive Engineer. 3. The tiles should be of reputed approved brand. 4. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

103.54

1308

-

... More
Providing and laying matt finish ceramic tiles of having sizes 30 centimetre X 30 centimetre and confirming to Indian Standard 15622 : 2006 (Group DII-A) and 7 milimetre to 8 milimetre thick for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with white / colour cement slurry, cleaning, curing, excetra complete. (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 24 / 215 Specification No : As per Item No 39a Spec. Page No : --- Additional Specifications : As per Item No 39a

25.65

1319

-

... More
Providing and laying ceramic tiles of having sizes 30 centimetre X 60 centimetre and confirming to corrosponding Indian Standard for dado and skirting in required position with ready made adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white / colour cement slurry, cleanding, curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 27 / 215 Specification No : Bd.M.13 Spec. Page No : 386 Additional Specifications : 1. The work shall be carried out as per direction of Engineer in-charge. 2. The work shall be carried out as per the sample approved from the Deputy Chief Architect, Public Works Deparment, Pune Region, Pune and kept in the office of the Executive Engineer. 3. The tiles should be of reputed approved brand. 4. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

71.96

1538

-

... More
Providing and laying ceramic tiles of having sizes 30 centimetre X 60 centimetre and confirming to corrosponding Indian Standard for dado and skirting in required position with ready made adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white / colour cement slurry, cleanding, curing, excetra complete. (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 27 / 215 Specification No : As per Item No 40a Spec. Page No : --- Additional Specifications : As per Item No 40a

61.74

1552

-

... More
Providing and laying ceramic tiles of having sizes 30 centimetre X 60 centimetre and confirming to corrosponding Indian Standard for dado and skirting in required position with ready made adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white / colour cement slurry, cleanding, curing, excetra complete. (For 2nd Floor) (using ARTIFICIAL SAND). Item / Page No : 27 / 215 Specification No : As per Item No 40a Spec. Page No : --- Additional Specifications : As per Item No 40a

43.74

1566

-

... More
Providing and fixing White Glazed Earthenware Squatting plate (Ladies Urinal) with polyvinyl chloride flushing cistern of 5 liters capacity with fitting, inlet pipes and stop tap, brackets for fixing the cistern, 32 milimetre diameter P.V.C flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap, soil pipe connection up to the outside face of the wall. (For Ground Floor) Item / Page No : 58 / 271 Specification No : Bd.V.23 Spec. Page No : 562

4

4581

-

... More
Providing and constructing brick masonry inspection chamber 60 centimetre X 45 centimetre X 90 centimetre including 1:4:8 cement concrete foundation, 1:2:4 cement concrete channels, half round glazed stoneware pipes, brick masonary, plastering from inside and farme fixed in cement concrete Cover medium duty 140 kilogram with frame excetra complete. (using ARTIFICIAL SAND). Item / Page No : 12 / 275 Specification No : Bd.V.43 Spec. Page No : 574 Additional Specifications : 1. Minimum two drums of water shall be provided to masons for soaking of bricks at each place where masons are working. 2. For mixing of mortar steel forms of required size only shall be used For mixing of mortar, steel tough or back platform shall be used. 3. The joints on inner face shall be raked to a depth of not less than the thickness of joints for affording good bond plaster. 4. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. 5. The sample of reinforced cement concrete cover shall be got approved by Engineer in-charge.

2

10057

-

... More
Providing and fixing wall hung white wash basin of size 550 milimetre X 400 milimetre X 195 milimetre with pillar cock having flow rate up to 6.0 Litr/Minute, C.P. Angular stop cock long thread of Jaquar/ Cera/ Hindware/ Perryware or equivalent make including stainless steel bottle trap of approved make, etc. complete as directed by Engineer in charge. (For Ground Floor) Item / Page No : 32 / 315 Additional Specifications : Work shall be carried out as per the instructions of Engineer In-Charge.

2

6648

-

... More
Providing and fixing machine cut mirror polished 18 milimetre to 20 milimetre thick telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone partition with rounding / moulding the edegs, excetra complete. - Both side polish (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 36 / 216 Specification No : Bd.M.35B Spec. Page No : 393 Additional Specifications : 1. The work shall be carried out as per instructions of Engineer in-charge. 2. The work shall be carried out as per the sample approved by the Engineer in-charge and kept in the office of the Executive Engineer. 3. The edge of partition should be rounded as directed. 4. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

9.45

4415

-

... More
Providing and laying cast in situ / Ready Mix Cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete pardi of required thickness including centering, formwork, cover blocks, compacting, finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement, including cover block) Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin excetra with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 17 / 185 Specification No : Bd.F.11, B-7 Spec. Page No : 304, 38-40 Additional Specifications : 1. The appropriate mix design shall be got done well in advance from the approved government laboratory and the same shall also be got approved from Engineer in-charge, before starting the work. 2. Cement from the same stock sent for mix design shall be used for concreting work. 3. The minimum cement for reinforced cement concrete / plain concrete to ensure durability / strength shall be as per IS 456-2000 with latest ammendment. If actual cement required / consumed is more than the provision in the IS code / approved mix design, no claim for that shall be entertained and cost for that shall be bourned by the contractor. 4. Before concreting work, cement from each consignment shall be got tested and if the strength of cement varies considerably from the approved mix design, the mix design should be got modified according to strength of fresh cement available in stock and concreting work should be done according to modified mix design. 5. For every consignment of cement, a sample shall be got tested as per norms and frequency of Vigilance and Quality Control Circle, Pune. As regards testing of cement it will be entire responsibility of the contractor. 6. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

0.2

17635

-

... More
Providing and laying cast in situ / Ready Mix Cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete pardi of required thickness including centering, formwork, cover blocks, compacting, finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement, including cover block) Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin excetra with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 17 / 185 Specification No : As per Item No 45a Spec. Page No : --- Additional Specifications : As per Item No 45a

0.2

17789

-

... More
Providing and laying cast in situ / Ready Mix Cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete pardi of required thickness including centering, formwork, cover blocks, compacting, finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement, including cover block) Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin excetra with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For 2nd Floor) (using ARTIFICIAL SAND). Item / Page No : 17 / 185 Specification No : As per Item No 45a Spec. Page No : --- Additional Specifications : As per Item No 45a

0.2

17944

-

... More
Providing and fabricting structural steel work in rolled sections like joists, channels, angles, tees, excetra as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted / welded connections without connecting plates, braces, excetra and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade, excetra complete. (For Ground Floor) Item / Page No : 1 / 173 Specification No : Bd.C.2 Spec. Page No : 275

0.025

112046

-

... More
Providing and fabricting structural steel work in rolled sections like joists, channels, angles, tees, excetra as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted / welded connections without connecting plates, braces, excetra and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade, excetra complete. (For First Floor) Item / Page No : 1 / 173 Specification No : As per Item No 46a Spec. Page No : --- Additional Specifications : As per Item No 46a

0.025

113065

-

... More
Providing and fabricting structural steel work in rolled sections like joists, channels, angles, tees, excetra as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted / welded connections without connecting plates, braces, excetra and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade, excetra complete. (For 2nd Floor) Item / Page No : 1 / 173 Specification No : As per Item No 46a Spec. Page No : --- Additional Specifications : As per Item No 46a

0.025

114083

-

... More
Providing and fixing board displaying information, such as 'Name of work, Tender cost, Name of Contractor, Work completion and liability period etc', having rectangular shape of 1.20 metre X 0.90 metre size made out 18 gauge (1.25 milimetre) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols excetra with approved colour shade paint complete, on M.S.angle of size 35 milimetre X 35 milimetre X 3 milimetre frame with properly cross braced mild steel angles of size 35 milimetre X 35 milimetre X 3 milimetre duly painted including two mild steel angle iron posts of size 65 milimetre X 65 milimetre X 6 milimetre, 3.65 metre long painted with alternate black and white bands of 25 centimetre width including all fixtures excetraand fixing the boards in 1:4:8 concrete block of size 60 centimetre X 60 centimetre X 75 centimetre including, excavation, refilling, transportation, and labour etc complete. Spec. number As directed by Engineer in Charge Item / Page No : 36 / 60 Specification No : MoRTH-801 Spec. Page No : --- Additional Specifications : The work shall be carried out as per instructions of Engineer in charge.

1

10939

-

... More
Laboratory testing charges for various materials required for items of work, on the basis of testing frequency and charges fixed by Vigilence and Quality Control Circle, Pune. Item / Page No : 4 / 0 Additional Specifications : 1. The amount of the laboratory testing charges will be paid to the contractor after submission of the original receipt from the Office of the Vigilance and Quality Control with name of work mensioned on the original receipt within the stipulated period of work. 2. The frequency of tests will be as per the instructions of Vigilance and Quality Control, Pune; vide their letter No. Prasha/2647/ 2010 dated 30/10/2010. 3. No extra claim shall be entertained on account of additional tests required and material transportation charges for tests. 4. In addition to above, the conditions under clause 25 - Samples and Testing of Material, under 'Additional General Conditions and Specifications' of this tender document shall be applicable. 5. Above / below percentage quoted by the contractor will not be applicable for this item.Fineness Modulus (Sieve Analysis), Silt and Clay Content Test for Artificial Sand 1 Test per Source

1

1450

-

... More
Compressive Strength of Cement Concrete Cube 1 Test for quantity upto 5 cubic metre, 2 Tests for quantity above 5 cubic metre and upto 15 cubic metre, 3 Tests for quantity above 15 cubic metre and upto 30 cubic metre, 4 Tests for quantity above 30 cubic metre and upto 50 cubic metre. For quantity 50 cubic metre and above - 4 Tests + 1 Test for each additional 50 cubic metre

6

725

-

... More
Sieve Analysis Test for Metal below 40 milimetre 1 Test per 200.00 Cubic Metre

1

725

-

... More
Water Absorption, Specific Gravity, Impact Value, Crushing Value Test for Metal below 40 milimetre 1 Test per Source

1

2730

-

... More
Concrete Mix Design (with all tests on basic materials) for Grade M-20 1 Test per 500.00 Cubic Metre

1

14445

-

... More
Water Absorption, Compressive Strength, Efflorescence Test for Burnt Bricks 1 Test per 50000.00 Number

1

2285

-

... More
Liquid Limit & Plastic Limit for Plinth Filling 1 Test per 1000.00 Cubic Metre

1

1230

-

... More
Tensile Strength, Percent Elongation, Yield Stress, Weight per Metre, Bend / Rebend Test, Proof Stress (Steel Bar upto 16 milimetre) 1 Test per 5.00 Metric Ton

2

1340

-

... More
Tensile Strength, Percent Elongation, Yield Stress, Weight per Metre, Bend / Rebend Test, Proof Stress (Steel Bar above 16 milimetre) 1 Test per 5.00 Metric Ton

3

1675

-

... More
Water Absorption, Modulus of Rupture Test for Ceramic / Vitrified Tiles 1 Test per 2000.00 Number

1

1675

-

... More
Compressive Strength, Water Absorption Test for Paving Blocks - 60 milimetre thick, 300 Kilogram per Square Centimetre Strength 1 Test per Square Metre

1

2620

-

... More
Fineness Modulus (Sieve Analysis), Silt and Clay Content Test for Sand 1 Test per Source

1

1450

-

... More
Providing and fixing 10 centimetre poly vinyl chloride nahani trap with grating, excetra complete. (For First Floor) Item / Page No : 67 / 281 Specification No : Bd.V.32A Spec. Page No : 551 Additional Specifications : The work shall be done as per instructions of Engineer in charge.

10

597

-

... More
Providing and fixing 10 centimetre poly vinyl chloride nahani trap with grating, excetra complete. (For 2nd Floor) Item / Page No : 67 / 281 Specification No : As per Item No 49a Spec. Page No : --- Additional Specifications : As per Item No 49a

10

602

-

... More
Providing and laying in trenches 25 milimetre diameter chlorinated poly vinyl chloride pipe including necessary excavation, fittings, refilling trenches, excetra complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed excetra complete. Item / Page No : 63 / 281 Specification No : Bd.V.5 Spec. Page No : 551 Additional Specifications : 1. The work shall be done as per instructions of Engineer in charge. 2. The specified diametre of the pipe shall refer to the inside diametre of the pipe and fittings. 3. Screw clips and fittings shall be of standard type to match the pipe.

30

464

-

... More
Provoding and fixing high density polyethylen container one piece moulded water tank made out of high density polyethylen and built corrugated inclusive of delivery upto destination housing, fixing of accessaries such as inlet, outlet, overflow pipe inclusive of all Taxes - Capacity between 1000 litres to 20000 litres. (For 2nd Floor) Item / Page No : 54 / 280 Additional Specifications : The work shall be done as per instructions of Engineer in charge.

6000

12

-

... More
Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 milimetre X 38 milimetre X 1.22 milimetre box type, 5 milimetre thick sheet glass louvers of approved quality, excetra complete. (For 2nd Floor) Item / Page No : 68 / 259 Additional Specifications : The work shall be done as per instructions of Engineer in charge.

5.4

3876

-

... More
Providing and applying external raincoat painting with crack filling acrylic polymer based chemical compound coating to the external surface of walls to prevent water seepage in the masonry walls during monsoon added with required shade Steiner to give required shade to the surface in two coats. Including providing three coat of priming of polymer base primer including preparing surface scrapping the existing loose old paint, removing loose particles of sand on the surface opening and cleaning the cracks developed in the external plaster, removing loose particles by chiseling, filling cracks by chemicals compound of approved make with proper penetration excetra Coating of Raincoat with the help of brush and as per instructions and specification given by manufacturer and with instruction from Engineer in-charge. Work shall be executed by certified applicator only and covering gurantee of 3 years on court stamp paper of Rs. 500/- and necessary testing, excetra complete. (For 2nd Floor) Item / Page No : 29 / 226 Additional Specifications : 1. The shade of paints shall be got approved by the Engineer in-charge before use. 2. The paints shall be of Indian Standards and from approved manufactures. The paints shall be got approved before use.

332.13

289

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.