Rural Development Department Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Rural Development Department - RDD Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date13 Dec 2024
Closing Soon27 Dec 2024
Tender Amount₹ 22,85,046.73 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

  • EMD

    ₹ 1,500
  • Document Cost

    ₹ 23,000
  • Tender Fee

    ₹ 500

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing and laying cast in situ / Ready Mix Cement Concrete M-20 for double rim bored pile of 450 milimetre diameter each of load capacity as per design and of specified diameter of pile and bulb as directed, sunk to the required depth through all strata except rock,excluding provision of reinforcement including placing with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer), excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed, excetra) by tremie arrangement compaction of concrete including chipping and dressing, excetra complete. (Excluding steel reinforcement) (using ARTIFICIAL SAND). Item / Page No : 14 / 161 Specification No : Bd.B.2 Spec. Page No : 269 Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

70

2787

195104

... More
Providing and laying cast in situ / Ready Mix Cement Concrete M-20 for double rim bored pile of 300 milimetre diameter each of load capacity as per design and of specified diameter of pile and bulb as directed, sunk to the required depth through all strata except rock,excluding provision of reinforcement including placing with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer), excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed, excetra) by tremie arrangement compaction of concrete including chipping and dressing, excetra complete. (Excluding steel reinforcement) (using ARTIFICIAL SAND). Item / Page No : 12 / 160 Specification No : Bd.B.2 Spec. Page No : 269 Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

48

1361

65340

... More
Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap metal for reinforced cement concrete pile caps as per detailed designs and drawings, including bailing out water manually, centering, formwork, laying/ pumping, compacting, finishing and curing excetra with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With natural sand/V.S.I. quality Artificial Sand, complete. (Excluding steel reinforcement) (using ARTIFICIAL SAND). Item / Page No : 59 / 171 Specification No : Bd.F.1 Spec. Page No : 297 Additional Specifications : 1. The work shall be carried out as directed by Engineer-In-Charge. 2. With additional specifications for controlled concrete. 3. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

4.48

7905

35417.98

... More
Providing and laying in situ/Ready Mix cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete work in foundations like raft, strip foundations, grillage and footings of reinforced cement concrete columns and steel stanchions, excetra including bailling out water, formwork, cover blocks, compaction, curing and roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel), excetra complete, with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (using ARTIFICIAL SAND). Item / Page No : 11 / 178 Specification No : Bd.F.3, B-7 Spec. Page No : 298, 38-40 Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

1.35

7475

10092.33

... More
Providing and laying cast in situ / Ready Mix cement conrete M-20 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete columns as per detailed designs and drawing or as directed, including steel centering, formwork, cover blocks,aying/pumping, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete.with fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 31 / 179 Specification No : Bd.F.5, B-7 Spec. Page No : 300, 38-40 Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

6.56

14154

92855.49

... More
Providing and laying cast in situ / Ready Mix cement conrete M-20 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete columns as per detailed designs and drawing or as directed, including steel centering, formwork, cover blocks,aying/pumping, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete.with fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 31 / 179 Specification No : As per Item No 8 Spec. Page No : --- Additional Specifications : As per Item No 8

5.8

14291

82890.12

... More
Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks,laying/pumping, compaction and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 50 / 181 Specification No : Bd.F.6, B-7 Spec. Page No : 300-301, 38-40 Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

11.35

12640

143473.08

... More
Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks,laying/pumping, compaction and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 50 / 181 Specification No : As per Item No 10 Spec. Page No : --- Additional Specifications : As per Item No 10

7.25

12762

92526.31

... More
Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap/ granite / quartzite/ gneiss metal for reinforced cement concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks,laying / pumping, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 70 / 182 Specification No : Bd.F.8, B-7 Spec. Page No : 302-303, 38-40 Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

9.68

14303

138460.78

... More
Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap/ granite / quartzite/ gneiss metal for reinforced cement concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks,laying / pumping, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 70 / 182 Specification No : As per Item No 12 Spec. Page No : --- Additional Specifications : As per Item No 12

9.68

14441

139797.59

... More
Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap metal for reinforced cement concrete chajja as per detailed design and drawings including centering, formwork, cover blocks, compacting, finishing and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate of natural sand/V.S.I. quality Artificial Sand (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 5 / 184 Specification No : BDF-9, B-7 Spec. Page No : 303-304, 38-40 Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

0.07

14303

1001.27

... More
Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap metal for reinforced cement concrete chajja as per detailed design and drawings including centering, formwork, cover blocks, compacting, finishing and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate of natural sand/V.S.I. quality Artificial Sand (For Ground Floor) (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 5 / 184 Specification No : As per Item No 14 Spec. Page No : --- Additional Specifications : As per Item No 14

0.5

14441

7220.95

... More
Providing and laying cast in situ / Ready Mix Cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete pardi of required thickness including centering, formwork, cover blocks, compacting, finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement, including cover block) Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin excetra with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 17 / 185 Specification No : Bd.F.11, B-7 Spec. Page No : 304, 38-40 Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

0.24

15938

3825.31

... More
Providing and laying cast in situ / Ready Mix Cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete pardi of required thickness including centering, formwork, cover blocks, compacting, finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement, including cover block) Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin excetra with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 17 / 185 Specification No : As per Item No 16 Spec. Page No : --- Additional Specifications : As per Item No 16

0.51

16093

8207.56

... More
Providing and laying cast in situ / Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete waist slab and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood / steel formwork, steel props, compaction, finishing uneven and honeycombed surface with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement, including cover block) Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin excetra with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 25 / 185 Specification No : Bd.F.13 Spec. Page No : 305 Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

0.92

12431

11437.26

... More
Providing and laying cast in situ / Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete waist slab and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood / steel formwork, steel props, compaction, finishing uneven and honeycombed surface with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement, including cover block) Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin excetra with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 25 / 185 Specification No : As per Item No 18 Spec. Page No : --- Additional Specifications : As per Item No 18

1.71

12551

21462.47

... More
Providing and fixing in position thermo mechnically treated FE-500 steel bar reinforcement of various dias for reinforced cement concrete pile caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardis, copings, fins, arches, excetra as per detailed designs, drawings and schedules including cutting, bendding, hooking the bars, binding with wires or tack welding and supporting as requied complete. (For Ground Floor) Item / Page No : 33 / 188 Specification No : Bd.F.17 Spec. Page No : 306

5.9

89868

530311.07

... More
Providing and fixing in position thermo mechnically treated FE-500 steel bar reinforcement of various dias for reinforced cement concrete pile caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardis, copings, fins, arches, excetra as per detailed designs, drawings and schedules including cutting, bendding, hooking the bars, binding with wires or tack welding and supporting as requied complete. (For First Floor) Item / Page No : 33 / 188 Specification No : As per Item No 20 Spec. Page No : --- Additional Specifications : As per Item No 20

3.05

90765

277196.31

... More
Providing second class burnt brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 in foundations and plinth of inner walls / in plinth of external walls including bailling out water manually, striking joints, on unexposed faces, racking out joints on exposed faces and watering, excetra complete. (using ARTIFICIAL SAND). Item / Page No : 1 / 197 Specification No : Bd.G.1 Spec. Page No : 313 Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

1.26

8351

10522.45

... More
Filling in plinth and floors with contractors material / brought from outside and approved by Engineer In-Charge, in 15 centimetre to 20 centimetre layers including watering and compaction, excetra complete. Item / Page No : 37 / 157 Specification No : Bd.A.11 Spec. Page No : 263-264

10.47

929

9734.48

... More
Providing second class Burnt Brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 superstructure including striking joints, racking out joints, watering and scaffolding, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 5 / 197 Specification No : Bd.G.5 Spec. Page No : 315 Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

19

8590

163212.85

... More
Providing second class Burnt Brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 superstructure including striking joints, racking out joints, watering and scaffolding, excetra complete. (For Ground Floor) (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 5 / 197 Specification No : As per Item No 24 Spec. Page No : --- Additional Specifications : As per Item No 24

1

8670

8670.1

... More
Providing second class Burnt Brick masonry with conventional / Indian Standard type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of 2 bars of 6 milimetre diameter / 2 hoop iron strips 25 milimetre X 1.6 milimetre placed at every third course, properly bent and bounded at ends, scaffolding, racking out joints and watering, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 6 / 197 Specification No : Bd.G.7 Spec. Page No : 316 Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

1

1189

1189.85

... More
Providing second class Burnt Brick masonry with conventional / Indian Standard type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of 2 bars of 6 milimetre diameter / 2 hoop iron strips 25 milimetre X 1.6 milimetre placed at every third course, properly bent and bounded at ends, scaffolding, racking out joints and watering, excetra complete. (For Ground Floor) (For First Floor) (using ARTIFICIAL SAND). Item / Page No : 6 / 197 Specification No : As per Item No 26 Spec. Page No : --- Additional Specifications : As per Item No 26

1

1201

1201.05

... More
Providing and fixing mild steel grill work for windows, ventilator, excetra 20 kilogram per square metre as per drawings including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting, excetra complete. (For Ground Floor) Item / Page No : 1 / 264 Specification No : Bd.U.1 Spec. Page No : 537

29.78

2100

62555.87

... More
Providing and fixing 50 milimetre diameter medium class galvanised iron pipe gate with wicked gate of approved drawing with all fixtures and fittings in two leaves with strong hold fast embedded in cement concrete block at top and bottom with locking arrangement incluing cutting, bending, making holes and with one coat of primer, excetra complete. Item / Page No : 5 / 173 Additional Specifications : The work shall be done as per instructions of Engineer in charge.

5.72

7257

41510.04

... More
Providing and fixing M-40 grade thick vibrated pull cast or similar type concrete frame with chamfer confirming to Indian Standard : 6524-1983 having 6 milimetre diameter bars three numbers and stirrups at 250 milimetre center to center and fixing in wall with six numbers of holdfast of 12 milimetre diameter bars 500 milimetre long including primer and oil painting, excetra complete. - Frame size 60 milimetre X 100 milimetre. (For Ground Floor) Item / Page No : 56 / 257 Additional Specifications : The work shall be done as per instructions of Engineer in charge.

5.7

1066

6076.2

... More
Providing internal cement plaster 20 milimetre thick in single coat in cement mortar 1:4 without neeru finish to concrete, brick surface, in all positions including scaffolding and curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 7 / 209 Specification No : Bd.L.4 Spec. Page No : 368 Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

91.2

389

35499.6

... More
Providing and fixing board displaying information, such as 'Name of work, Tender cost, Name of Contractor, Work completion and liability period etc', having rectangular shape of 1.20 metre X 0.90 metre size made out 18 gauge (1.25 milimetre) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols excetra with approved colour shade paint complete, on M.S.angle of size 35 milimetre X 35 milimetre X 3 milimetre frame with properly cross braced mild steel angles of size 35 milimetre X 35 milimetre X 3 milimetre duly painted including two mild steel angle iron posts of size 65 milimetre X 65 milimetre X 6 milimetre, 3.65 metre long painted with alternate black and white bands of 25 centimetre width including all fixtures excetraand fixing the boards in 1:4:8 concrete block of size 60 centimetre X 60 centimetre X 75 centimetre including, excavation, refilling, transportation, and labour etc complete. Spec. number As directed by Engineer in Charge Item / Page No : 36 / 60 Specification No : MoRTH-801 Spec. Page No : --- Additional Specifications : The work shall be carried out as per instructions of Engineer in charge.

1

9963

9963

... More
Royalty charges for various building construction bonafied materials which are used for government bonafied works and for which Royalty charges are to be paid by the contractor. (This Item is to be paid to the contractor only after he pays the Royalty amount to Revenue department and produces the required voucher.) Item / Page No : 3 / 0 Additional Specifications : 1. Government of Maharashtra, Revenue and Forest Department Gazette Number 146 Dated 04/06/2021 and Government of Maharashtra Public Works Department State Schedule of Rates 2021-22 General Note Number A(v), Page 5. 2. The amount of royalty charges will be paid only after submission of the receipt in original from Revenue authority for payment of royalty to Government, stating the name of work. 3. Above / below percentage quoted by the contractor will not be applicable for this item.

10.81

216

2336.91

... More
Laboratory testing charges for various materials required for items of work, on the basis of testing frequency and charges fixed by Vigilence and Quality Control Circle, Pune. Item / Page No : 4 / 0 Additional Specifications : 1. The amount of laboratory testing charges will be paid to contractor only after submission of the original receipt from the Vigillence and Quality Control Office with the name of work mensioned on it. 2. Above / below percentage quoted by the contractor will not be applicable for this item.

1

21600

21600



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.