Rural Development Department Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Rural Development Department - RDD Tender

Works
Civil And Construction
Civil Works Others
Eprocure
Opening Date31 Dec 2024
Closing Date15 Jan 2025
Tender Amount₹ 65,34,574 
Notes
Download

Costs

  • EMD

    ₹ 65,346
  • Document Cost

    ₹ 12,000
  • Tender Fee

    ₹ 500

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing and laying in situ/Ready Mix cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete work in foundations like raft, strip foundations, grillage and footings of reinforced cement concrete columns and steel stanchions, excetra including bailling out water, formwork, cover blocks, compaction, curing and roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel), excetra complete, with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (using ARTIFICIAL SAND). Item / Page No : 11 / 178 Specification No : Bd.F.3, B-7 Spec. Page No : 298, 38-40 Additional Specifications : 1. The appropriate mix design shall be got done well in advance from the approved government laboratory and the same shall also be got approved from Engineer in-charge, before starting the work. 2. Cement from the same stock sent for mix design shall be used for concreting work. 3. The minimum cement for reinforced cement concrete / plain concrete to ensure durability / strength shall be as per IS 456-2000 with latest ammendment. If actual cement required / consumed is more than the provision in the IS code / approved mix design, no claim for that shall be entertained and cost for that shall be bourned by the contractor. 4. Before concreting work, cement from each consignment shall be got tested and if the strength of cement varies considerably from the approved mix design, the mix design should be got modified according to strength of fresh cement available in stock and concreting work should be done according to modified mix design. 5. For every consignment of cement, a sample shall be got tested as per norms and frequency of Vigilance and Quality Control Circle, Pune. As regards testing of cement it will be entire responsibility of the contractor. 6. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

34.56

7901

273062.02

... More
Providing and laying cast in situ / Ready Mix cement conrete M-20 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete columns as per detailed designs and drawing or as directed, including steel centering, formwork, cover blocks,aying/pumping, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete.with fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 31 / 179 Specification No : Bd.F.5, B-7 Spec. Page No : 300, 38-40 Additional Specifications : 1. The appropriate mix design shall be got done well in advance from the approved government laboratory and the same shall also be got approved from Engineer in-charge, before starting the work. 2. Cement from the same stock sent for mix design shall be used for concreting work. 3. The minimum cement for reinforced cement concrete / plain concrete to ensure durability / strength shall be as per IS 456-2000 with latest ammendment. If actual cement required / consumed is more than the provision in the IS code / approved mix design, no claim for that shall be entertained and cost for that shall be bourned by the contractor. 4. Before concreting work, cement from each consignment shall be got tested and if the strength of cement varies considerably from the approved mix design, the mix design should be got modified according to strength of fresh cement available in stock and concreting work should be done according to modified mix design. 5. For every consignment of cement, a sample shall be got tested as per norms and frequency of Vigilance and Quality Control Circle, Pune. As regards testing of cement it will be entire responsibility of the contractor. 6. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

26.95

14907

401754.43

... More
Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including centering, formwork, cover blocks, compacting, finishing and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement, including cover block) Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin excetra with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 23 / 185 Specification No : Bd.F.12, B-7 Spec. Page No : 304-305, 38-40 Additional Specifications : 1. The appropriate mix design shall be got done well in advance from the approved government laboratory and the same shall also be got approved from Engineer in-charge, before starting the work. 2. Cement from the same stock sent for mix design shall be used for concreting work. 3. The minimum cement for reinforced cement concrete / plain concrete to ensure durability / strength shall be as per IS 456-2000 with latest ammendment. If actual cement required / consumed is more than the provision in the IS code / approved mix design, no claim for that shall be entertained and cost for that shall be bourned by the contractor. 4. Before concreting work, cement from each consignment shall be got tested and if the strength of cement varies considerably from the approved mix design, the mix design should be got modified according to strength of fresh cement available in stock and concreting work should be done according to modified mix design. 5. For every consignment of cement, a sample shall be got tested as per norms and frequency of Vigilance and Quality Control Circle, Pune. As regards testing of cement it will be entire responsibility of the contractor. 6. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

43.09

7991

344347.27

... More
Providing second class Burnt Brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 superstructure including striking joints, racking out joints, watering and scaffolding, excetra complete.For First Floor (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 5 / 197 Specification No : Bd.G.5 Spec. Page No : 315 Additional Specifications : 1. The brick shall be got tested before use, from the Government laboratory at the rate of one batch of 15 bricks for every 50000 bricks or part therof at the contractors cost for the following. A) Crushing strength:- i. Dry condition 5 bricks ii. Wet condition 5 bricks B) Water aborption 5 bricks 2. In addition, bricks shall be tested for size, shape and soundness. 3. The proportion of cement mortar shall be 1:6. 4. Minimum two drums of water shall be provided to masons for soaking of bricks at each place where masons are working. 5. For mixing of mortar steel forms of required size only shall be used For mixing of mortar, steel tough or back platform shall be used. 6. The brick work shall be cured for a minimum period of 14 days. 7. The joints on both faces shall be raked to a depth of not less than the thickness of joints for affording good bond plaster. 8. Hold fast of door or window frames shall be embedded in cast in situ 1:2:4 cement concrete blocks of required size without any extra cost. 9. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

170.11

9162

1558607.36

... More
Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks,laying/pumping, compaction and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 50 / 181 Specification No : Bd.F.6, B-7 Spec. Page No : 300-301, 38-40 Additional Specifications : 1. The appropriate mix design shall be got done well in advance from the approved government laboratory and the same shall also be got approved from Engineer in-charge, before starting the work. 2. Cement from the same stock sent for mix design shall be used for concreting work. 3. The minimum cement for reinforced cement concrete / plain concrete to ensure durability / strength shall be as per IS 456-2000 with latest ammendment. If actual cement required / consumed is more than the provision in the IS code / approved mix design, no claim for that shall be entertained and cost for that shall be bourned by the contractor. 4. Before concreting work, cement from each consignment shall be got tested and if the strength of cement varies considerably from the approved mix design, the mix design should be got modified according to strength of fresh cement available in stock and concreting work should be done according to modified mix design. 5. For every consignment of cement, a sample shall be got tested as per norms and frequency of Vigilance and Quality Control Circle, Pune. As regards testing of cement it will be entire responsibility of the contractor. 6. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

17.01

13319

226559.59

... More
Providing sand faced plaster externally in cement mortar using approved screened sand in all positions including base coat of 15 milimetre thick in cement mortar 1:4 using waterproofing compound at one killogramme per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment of 6 to 8 milimetre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days, scaffolding, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 11 / 209 Specification No : Bd.L.7 Spec. Page No : 369 Additional Specifications : 1. The surface to be plastered shall be first cleaned and thoroughly wetted for 24 hours and got checked from Engineer in-charge before starting the work. 2. Item includes rounding of all internal and external junctions, corners, jambs, etc. as directed by the Engineer in-charge. 3. Finishing shall be plain and in line, level and plumb. 4. Curing shall be done by sprinkling water on the surface for minimum period of 14 days. 5. Application of sand faced treatment shall be commenced only after passing the base coat Engineer in-charge. 6. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

2169.91

682

1480095.61

... More
Providing and fixing in position thermo mechnically treated FE-500 steel bar reinforcement of various dias for reinforced cement concrete pile caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardis, copings, fins, arches, excetra as per detailed designs, drawings and schedules including cutting, bendding, hooking the bars, binding with wires or tack welding and supporting as requied complete. (For Ground Floor) Item / Page No : 33 / 188 Specification No : Bd.F.17 Spec. Page No : 306 Additional Specifications : 1. Steel to be used must be as per Indian Standard : 1786 (1985) with latest amendments and manufactured by approved and reputed make. 2. Steel to be used must be procured directly from the manufacturers or from authorised agent of main producers. 3. Various diameters of TMT-FE-500 steel bars brought on site of the work shall be got tested category wise and lot wise, as directed by the Engineer In-Charge and minimum 50 percent of testing should be done in the departmental laboratory.

8.08

94263

761837.2

... More
Providing and fixing 50 milimetre diameter medium class galvanised iron pipe gate with wicked gate of approved drawing with all fixtures and fittings in two leaves with strong hold fast embedded in cement concrete block at top and bottom with locking arrangement incluing cutting, bending, making holes and with one coat of primer, excetra complete. Item / Page No : 5 / 173 Additional Specifications : The work shall be done as per instructions of Engineer in charge.

20

7612

152252

... More
Laboratory testing charges for various materials required for items of work, on the basis of testing frequency and charges fixed by Vigilence and Quality Control Circle, Pune. Item / Page No : 4 / 0 Additional Specifications : 1. The amount of the laboratory testing charges will be paid to the contractor after submission of the original receipt from the Office of the Vigilance and Quality Control with name of work mensioned on the original receipt within the stipulated period of work. 2. The frequency of tests will be as per the instructions of Vigilance and Quality Control, Pune; vide their letter No. Prasha/2647/ 2010 dated 30/10/2010. 3. No extra claim shall be entertained on account of additional tests required and material transportation charges for tests. 4. In addition to above, the conditions under clause 25 - Samples and Testing of Material, under 'Additional General Conditions and Specifications' of this tender document shall be applicable. 5. Above / below percentage quoted by the contractor will not be applicable for this item.Standard Consistancy, Fineness, Specific Gravity, Setting Time (Initial and Final), Compressive Strength, Soundness Test for Cement 1 Test per 50.00 Metric Ton

1

14687

14687

... More
Providing and fixing 90 centimetre X 60 centimetre granite name plate engraving 10 centimetre height letter, figures including painting the letters / figures with approved colour and shade complete. Item / Page No : 12 / 294 Specification No : Bd.W.7 Spec. Page No : 586-587

1

9049

9049.7

... More
ADD INSURANCE TOWARDS 0.50% Non-Dsr Item Additional Specifications : The work shall be carried out as per the instructions of Engineer in-charge.

1

54935

54935

... More
ADD G.S.T. 18.0% Non-Dsr Item Additional Specifications : The work shall be carried out as per the instructions of Engineer in-charge.

1

986179

986179



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.