Rural Development Department Tender

... More
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Rural Development Department - RDD Tender

Works
Civil And Construction
Construction Material
Eprocure
Opening Date29 Jul 2024
Closing Date16 Aug 2024
Tender Amount₹ 44,91,06,715 
Notes
Download

Costs

Summary

Package No. Rd-san-a286, Eleven Road Works In Tal- Atapdi, Khanapur And Tasgaon, Dist- Sangli

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cubicmeter bucket capacity including cutting and loading in tippers, transporting to embankment site with a lift upto 1.5 meter and lead above 100 meter, trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections as per Technical Specification Ministry Of Rural Development 2014 Clause 302.3.5 And As Directed by Engineer Incharge

667.15

76121

114.1

... More
Scarifying existing bituminous surface to a depth of 150 mm and disposal of scarified material with a lift upto 3 m and leads upto 1000 m as per Technical Specification Clause 301.4. as per Technical Specification Clause 301.4 And As Directed by Engineer Incharge

16260

269916

16.6

... More
Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Ministry Of Rural Development 2014 Clause 301.5 And As Directed by Engineer Incharge

2058.2

181224

88.05

... More
Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 And As Directed by Engineer Incharge

5734.72

3590221

626.05

... More
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 as per Technical Specification Ministry Of Rural Development 2014 Clause 303.1. And As Directed by Engineer Incharge

4528.05

3325402

734.4

... More
Loosening, Levelling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 milimeter, mixed with water at optimum moisture content and then compacted by rolling so as to achieve minimum dry density as given in Tables 300.1 and 300.2 for embankment construction as per Technical Specification Clause 301.4.1.And As Directed by Engineer Incharge And As Directed by Engineer Incharge

588

20315

34.55

... More
Setting Out And As Directed by Engineer Incharge

6.02

157602

26179.74

... More
Construction of Granular sub-base grade -II by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator and compacting with vibretary wheel roller to achieve the desired density, complete as per Technical Specification Ministry Of Rural Development 2014 Clause 401. And As Directed by Engineer Incharge

969.18

2171883

2240.95

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kilonewton static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Water bound macadum Grading 2 as per Technical Specification Ministry Of Rural Development 2014 Clause 405. For - By Mechanical Means And As Directed by Engineer Incharge

690.86

1671121

2418.9

... More
Providing and laying White Topping/Short Paneled Concrete as per IRC-SP 76-2015 (Existing surface preparation to be done if necessary either by milling or leveling course with DLC to correct surface profile and to be paid separately) with un reinforced M-40 grade Pavement Quality Concrete using Ordinary Portland Cement 43/53 Grade OR Portland Pozzolona Cement IS-1489 at 425kg/cum, coarse aggregate, fine aggregate(VSI) and Admixture confirming to IS 9130-1999 (R-2004) polymeric synthetic fiber as per ASTM (1116) such as polyester / polyethylene / polypropylene / Glass fiber at 1.20 kg/cum, mixed in batching and mixing plant or weigh batcher as per approved mix design to achieve minimum flexural strength or modulus of rupture of concrete 4.50 MPa at 28 days limiting maximum water cement ratio to 0.40, transported to site, laid with fixed form/ slip form paver finisher (preferably with slip form paver finisher), spread, vibrated, compacted and finished in a continuous operation to the lines and grades as per drawing, texture finishing of surface, spraying two layers of curing compound, curing with water sprayed on hessian cloth covered over concrete surface, groove cutting grid 1m x 1m or as directed by Engineer Incharge to a depth of 1/3 to 1/4 of the Thickness and of width 3-5 mm as per design including cost of all material, side form work, labour and machineries etc. complete as per specifications.(Excluding Dowel Bars and Tie Bars) ( Including Polythene sheet 125 micron) And As Directed by Engineer Incharge

3494.7

27705457

7927.85

... More
Providing & Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to 15: 383, the size of coarse aggregate not exceeding 25 mm, , cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days,mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts,laid with a paver with electronic sensor /by suitable means as approved by Engineer-in charge , compacting with vibratory roller, finishing, curing and including preparation of sub-grade surface if required etc. complete. And As Directed by Engineer Incharge

2514.19

9334433

3712.7

... More
Providing and fixing in position 25mm dia anti corrosive MS dowel bars of required Dia. 60 cms. Long and at 30.00cm C/C and wherever directed including handling, straightening, necessary cutting supported by chairs with proper alignment with half length covered by polyethene sheathhing including cap etc. cpmpleted .And As Directed by Engineer Incharge

780

190242

243.9

... More
Providing and fixing in position anticorrosive TMT FE 500 tie bars of 12mm dia. 70cms long and 30.00cm. C/C and wherever directed including handling, straightening, necessary cutting, handling, straightening, supported by assembly of TMT FE 500, Chairs with proper alignement etc. completed. And As Directed by Engineer Incharge

20229

1348262

66.65

... More
Dismantling Stone Masonry as per Technical Specification MORD 2014 Clause 202. Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification MORD 2014 Clause 202. Rubble Stone Masonry in Cement Mortar And As Directed by Engineer Incharge

73.88

46610

630.9

... More
Removing all types of Hume pipes and stacking within a lead of 1000 m including Earthwork and Dismantling of Masonry Works as per Technical Specification MORD 2014 Clause 202. Upto 600 mm dia Hume pipe And As Directed by Engineer Incharge

45

27787

617.5

... More
Earthwork in excavation for structures as per drawing and technical specifications Ministry Of Rural Development 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 meter, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary soil And As Directed by Engineer Incharge

663.37

466846

703.75

... More
Earthwork in excavation for structures as per drawing and technical specifications Ministry Of Rural Development 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 meter, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary rock (not requiring blasting) Upto 3 meter depth And As Directed by Engineer Incharge

239.94

211075

879.7

... More
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Hard rock (blasting prohibited) Upto 3 meter depth And As Directed by Engineer Incharge

70.51

87210

1236.85

... More
Filling in foundation trenches as per drawing and technical specification Clause 305.3.9 Rubble soling with Rubble And As Directed by Engineer Incharge

62.52

146803

2348.1

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 Plane cement concreate grade M 10 Nominal mix 1:3:6 And As Directed by Engineer Incharge

105.43

695695

6598.65

... More
Providing concrete for plain/reinforced concrete in sub structure complete as per drawings and technical specifications Ministry Of Rural Development 2014 Clause 802, 803, 804, 805, 806, 807, 1202 & 1203, 1204 Plain cement concreate grade M 15 Nominal mix (1:2.5:5) And As Directed by Engineer Incharge

615.93

4226881

6862.6

... More
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. B. 1000 milimeter Non pressure 3 Class As per Technical Specification Ministry Of Rural Development 2014 Cluase No. 1100 And As Directed by Engineer Incharge

120

951270

7927.25

... More
Providing and laying reinforced cement concrete pipe Non pressure2 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. D. 600 milimeter Non pressure 2 Class As per Technical Specification Ministry Of Rural Development 2014 Cluase No. 1100 And As Directed by Engineer Incharge

542.5

1556785

2869.65

... More
Providing and laying cement concrete wearing course M30 grade Excluding reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3 And As Directed by Engineer Incharge

69.3

1029420

14854.55

... More
Supplying, fitting and placing TMT bar reinforcement (Fe 415) in sub structure complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202 And As Directed by Engineer Incharge

4.13

344316

83369.65

... More
Providing weepholes in brick masonry / stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 milimeter dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7 A.C. pipe 100 milimeter Dia And As Directed by Engineer Incharge

40

12744

318.6

... More
Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1303 And As Directed by Engineer Incharge

430.7

965263

2241.15

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per Indian Road Congress:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Ministry Of Rural Development 2014 Clause 1703 5th Kilometre Stone (Precast) And As Directed by Engineer Incharge

1

5363

5363.5

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per Indian Road Congress:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Ministry Of Rural Development 2014 Clause 1703 Ordinary Kilometer Stone (Precast) And As Directed by Engineer Incharge

6

18735

3122.6

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per Indian Road Congress:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Ministry Of Rural Development 2014 Clause 1703 200 meter stone (precast) And As Directed by Engineer Incharge

24

21018

875.75

... More
Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per Indian Road Congress:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704. And As Directed by Engineer Incharge

572

504732

882.4

... More
MMGSY / PMGSY Citizen' s information Board- Providing and fixing of typical PMGSY Retro Reflective information board as per as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circular and drawing. Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottom duly rivetted with MS angles of 35 x 35 x 5 mm thick M.S angle shall be welded by two vertical M.S angle of 5 mm thick to 75 mm x 75 mm of 12 SWG square tubes / 75mm Dia Pipe posts duly embedded in cement concrete M-20 grade blocks of 600mm x 600mm x 75mm, below ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circular no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4 and as directed by Engineer-In-charge. . A warranty for 5 / 7 years for the Retro reflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor And As Directed by Engineer Incharge.

2

60238

30119.25

... More
Providing and fixing of typical Mukhya Mantri Gram Sadak Yojana informatory sign board with Logo as per Ministry Of Rural Development specifications and drawing. Three Mild steel Plates of 1.6 mm thick, top and middle plate duly welded with Mild steel flat iron 25Millimeter x 5meter size on back on edges. The lower plate will be welded with Mild steel angle iron frame of 25 Millimeter x 25 Millimeter x 5 Millimeter. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75Millimeter x 75 Millimeter of 12 Steel wire Gause sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450Millimeter x 450Millimeter x 600Millimeter, 600Millimeter below ground level. The top most diamond plate will be welded to middle plate by 47Millimeter x 47Millimeter of 12 Steel wire Gauge steel plate tube. All Mild steel will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 'Logo' of Mukhya Mantri Gram Sadak Yojana Project And As Directed by Engineer Incharge

1

19266

19266.15

... More
Providing and erecting direction and place identification of semi reflective sign boards as per IRC-67 made of 2 mm thick M.S. Sheet duly stove enameled paint white colour in front and grey colour on back with reflective border of 70 mm width and required message, letters, figures with reflective tape of engineering grade as per MORD specifications of required shade and colour. Supported and welded on two nos. 47 mm x 47 mm of 12 SWG square tube of 3050 mm height duly strengthened by 25 mm x 5 mm MS flat iron on edges on back firmly fixed to the ground by means of properly designed foundations with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701 And As Directed by Engineer Incharge

12

51779

4314.95

... More
Providing and fixing Cautionary/Warning sign boards in Equilateral Triangle size of mm made out of mm aluminum sheet bonded with white retro reflective sheeting of Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3 Supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with grey stove enamel paint and supported on one no. of M. S. angle iron post of size 65 mm X 65 mm X 6 mm, 3.45 m long, duly painted with with flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in M25 grade concrete block of size 60cm X 60cm X 75cm including transportation etc; complete. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier. And As Directed by Engineer Incharge

54

217104

4020.45

... More
Providing and fixing of retro- reflectorised informatory sign board rectangular/Square in shape having area less than 0.9 One Square Meterr made out of mm aluminum sheet bonded with white retro reflective sheeting of Class ( Type IV High intensity micro- prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3, supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with two coats of grey stove enamel paint and supported on one no. mild steel angle iron post 75 mm x 75 mm x 6 mm, 3.5 mt long firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing The angle iron post shall be duly painted with one coat of epoxy primer and two coats of epoxy finish paints having alternate black and white bands of 25 cm width including GI fixures and transportation etc.complete.The nut bolts of board with angle iron post/supporting structure after fixing at site has to be electrically welded. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) sheeting shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier. 600 x 450 milimeter Rectangular And As Directed by Engineer Incharge

3.78

38368

10150.35

... More
Providing and fixing Mandatory/Regulatory sign boards in circular shape of mm dia made out of mm aluminum sheet bonded with white retro reflective sheeting of Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3 Supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with grey stove enamel paint and supported on one no. of M. S. angle iron post of size 65 mm X 65 mm X 6 mm, 3.45 m long, duly painted with with flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in M25 grade concrete block of size 60cm X 60cm X 75cm including transportation etc; complete. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier. 600mm circular And As Directed by Engineer Incharge

59

279766

4741.8

... More
Providing and Laying hot applied thermoplastic road marking strip on Bituminous Surface of specified shade/ colour of 2.5 mm thick including 1.5 Refractive index reflectorizing glass beads @ 250gm/sqm .Thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC 35:2015. Initial Dry reflectivity RL shall be 250 mcd/sqm/lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/sqm/ lux and Qd of 100 mcd/sqm/ lux measured at the end of 2 years by means of a Standard Reflectometer of Zehntner, Easylux, Delta make capable of measuring RL & QD both according to IRC 35:2015 clause 15.5. The finished surface to be level, uniform, and free from streaks and holes complete as per direction of Engineer-in-charge and in accordance with applicable specifications.(Refer MORTH Clause 803 for technical Specification and Performance for IRC 35:2015) And As Directed by Engineer Incharge

1214.5

849299

699.3

... More
Road Delineators: Supplying and installation of delineators (Roadway Indicators, Hazard markers, Object markers) 80 to 100 cm high above ground level, painted black and white in 15cm wide strips, fitted with 80x100mm rectangular or 75mm dia. Circular reflectorised panels at the top, buried or pressed into the ground and confirming to I.R.C. 79 and the drawings And As Directed by Engineer Incharge

50

43155

863.1

... More
Providing and fixing in position Pipe Railing consisting of IS Rolled steel joist posts designation IS MB 100 (100x75) at 2.5 m interval and three rows of 50 mm dia steel pipes (light) including fixing in position on bridge deck complete as per drawing and technical specifications Clause 1208.2 And As Directed by Engineer Incharge

150

329160

2194.4

... More
Painting two coats including prime coat with epoxy paint of approved brand on concrete/steel surfaces after through cleaning of surface to give an even shade as per drawing and Technical Specification Clause 1701 And As Directed by Engineer Incharge

1.44

250

173.75

... More
White washing two coats on parapet walls and white washing and geru lime painting to tree trunks including preparation of surface by cleaning scraping etc. complete And As Directed by Engineer Incharge

20

546

27.3

... More
A,W : Metal Beam Crash Barrier (Providing and erecting a "W "metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip cess, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810) And As Directed by Engineer Incharge

360

1856736

5157.6

... More
Providing and Laying of 2 or more sets (6Nos. each set) Dual Ribs Pattern Rumble Markings on roads with vehicular speeds of more than 50 Km/hr laid as per the spacing recommended for each set under Table11.1 and Fig.11.2 of IRC35:2015 using Plastirib 2K, or equivalent 2 component cold plastic profiled material. Each Dual Rib pattern rumble marking shall have width of 500mm. Each dual rib pattern rumble marking shall have 2 ribs each of Width of 100mm and height 20mm. Gap between two ribs shall be 300mm. Each rumble marking shall be made complete with drop on Soild Plus reflective glass beads @ 300 gm / One Square Metre spread throughout the surface of marking. The finished surface to be levelled,uniform and free from streaks and holes,including surface cleaning and cost of all materials etc. complete. And As Directed by Engineer Incharge.

10.5

47771

4549.65

... More
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. And As Directed by Engineer Incharge

139.75

95267

681.7

... More
Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete And As Directed by Engineer Incharge

465.84

27880

59.85

... More
B) Improvement of Road from Shetphale to Chavarwasti(Ranmala) Road Ch 0/000 to 4/480, Taluka -Atpadi, District:-Sangli, Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 milimeter, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 meter including removal and disposal of top organic soil not exceeding 150 milimeter in thickness as per Technical Specification Ministry Of Rural Development 2014 Clause 201. By mechnical means (A) In area Non of thorny jungle And As Directed by Engineer Incharge

1.35

35816

26530.8

... More
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 milimeter, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 meter including removal and disposal of top organic soil not exceeding 150 milimeter in thickness as per Technical Specification Ministry Of Rural Development 2014 Clause 201.By mechnical means (B) In area of thorny jungle And As Directed by Engineer Incharge

0.9

29680

32978.7

... More
Excavation for roadwork in soil with hydraulic excavator of 0.9 cubicmeter bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with a lift upto 1.5 meter and lead more than 100 meter as per Technical Specification Ministry Of Rural Development 2014 Clause 302.3 And As Directed by Engineer Incharge

5217.68

385847

73.95

... More
Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cubicmeter bucket capacity including cutting and loading in tippers, transporting to embankment site with a lift upto 1.5 meter and lead above 100 meter, trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections as per Technical Specification Ministry Of Rural Development 2014 Clause 302.3.5 And As Directed by Engineer Incharge

1936.02

210445

108.7

... More
Excavation for roadway in hard rock (requiring blasting) by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross-sections, loading and disposal of cut rock with a lift upto 1.5 meter and leads upto 1000 meter as per Technical Specification Clause 302.3.5 And As Directed by Engineer Incharge

201.04

30266

150.55

... More
Scarifying existing bituminous surface to a depth of 150 mm and disposal of scarified material with a lift upto 3 m and leads upto 1000 m as per Technical Specification Clause 301.4. as per Technical Specification Clause 301.4 And As Directed by Engineer Incharge

6300

99540

15.8

... More
Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Ministry Of Rural Development 2014 Clause 301.5 And As Directed by Engineer Incharge

4448.06

372969

83.85

... More
Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 And As Directed by Engineer Incharge

4108.94

2475636

602.5

... More
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 as per Technical Specification Ministry Of Rural Development 2014 Clause 303.1. And As Directed by Engineer Incharge

3559.06

2512518

705.95

... More
Loosening, Levelling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 milimeter, mixed with water at optimum moisture content and then compacted by rolling so as to achieve minimum dry density as given in Tables 300.1 and 300.2 for embankment construction as per Technical Specification Clause 301.4.1.And As Directed by Engineer Incharge And As Directed by Engineer Incharge

2856

93962

32.9

... More
Setting out And As Directed by Engineer Incharge

4.48

116370

25975.53

... More
Construction of Granular sub-base grade -II by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator and compacting with vibretary wheel roller to achieve the desired density, complete as per Technical Specification Ministry Of Rural Development 2014 Clause 401. And As Directed by Engineer Incharge

1272.65

2814147

2211.25

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kilonewton static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Water bound macadum Grading 2 as per Technical Specification Ministry Of Rural Development 2014 Clause 405. For - By Mechanical Means And As Directed by Engineer Incharge

199.5

474700

2379.45

... More
Providing and laying White Topping/Short Paneled Concrete as per IRC-SP 76-2015 (Existing surface preparation to be done if necessary either by milling or leveling course with DLC to correct surface profile and to be paid separately) with un reinforced M-40 grade Pavement Quality Concrete using Ordinary Portland Cement 43/53 Grade OR Portland Pozzolona Cement IS-1489 at 425kg/cum, coarse aggregate, fine aggregate(VSI) and Admixture confirming to IS 9130-1999 (R-2004) polymeric synthetic fiber as per ASTM (1116) such as polyester / polyethylene / polypropylene / Glass fiber at 1.20 kg/cum, mixed in batching and mixing plant or weigh batcher as per approved mix design to achieve minimum flexural strength or modulus of rupture of concrete 4.50 MPa at 28 days limiting maximum water cement ratio to 0.40, transported to site, laid with fixed form/ slip form paver finisher (preferably with slip form paver finisher), spread, vibrated, compacted and finished in a continuous operation to the lines and grades as per drawing, texture finishing of surface, spraying two layers of curing compound, curing with water sprayed on hessian cloth covered over concrete surface, groove cutting grid 1m x 1m or as directed by Engineer Incharge to a depth of 1/3 to 1/4 of the Thickness and of width 3-5 mm as per design including cost of all material, side form work, labour and machineries etc. complete as per specifications.(Excluding Dowel Bars and Tie Bars) ( Including Polythene sheet 125 micron) And As Directed by Engineer Incharge

2621.23

20031439

7642

... More
Providing & Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to 15: 383, the size of coarse aggregate not exceeding 25 mm, , cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days,mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts,laid with a paver with electronic sensor /by suitable means as approved by Engineer-in charge , compacting with vibratory roller, finishing, curing and including preparation of sub-grade surface if required etc. complete. And As Directed by Engineer Incharge

1797.35

6521145

3628.2

... More
Providing and fixing in position 25mm dia anti corrosive MS dowel bars of required Dia. 60 cms. Long and at 30.00cm C/C and wherever directed including handling, straightening, necessary cutting supported by chairs with proper alignment with half length covered by polyethene sheathhing including cap etc. cpmpleted. And As Directed by Engineer Incharge

540

125469

232.35

... More
Providing and fixing in position anticorrosive TMT FE 500 tie bars of 12mm dia. 70cms long and 30.00cm. C/C and wherever directed including handling, straightening, necessary cutting, handling, straightening, supported by assembly of TMT FE 500, Chairs with proper alignement etc. completed. And As Directed by Engineer Incharge

15583

989520

63.5

... More
Removing all types of Hume pipes and stacking within a lead of 1000 m including Earthwork and Dismantling of Masonry Works as per Technical Specification MORD 2014 Clause 202. Upto 600 mm dia Hume pipe And As Directed by Engineer Incharge

37.5

22053

588.1

... More
Earthwork in excavation for structures as per drawing and technical specifications Ministry Of Rural Development 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 meter, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary soil And As Directed by Engineer Incharge

315.8

211664

670.25

... More
Earthwork in excavation for structures as per drawing and technical specifications Ministry Of Rural Development 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 meter, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary rock (not requiring blasting) Upto 3 meter depth And As Directed by Engineer Incharge

183.59

153820

837.85

... More
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Hard rock (blasting prohibited) Upto 3 meter depth And As Directed by Engineer Incharge

67.95

80041

1177.95

... More
Filling in foundation trenches as per drawing and technical specification Clause 305.3.9 Rubble soling with Rubble And As Directed by Engineer Incharge

15.26

34534

2263.05

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 Plane cement concreate grade M 10 Nominal mix 1:3:6 And As Directed by Engineer Incharge

51.66

329288

6374.15

... More
Providing concrete for plain/reinforced concrete in sub structure complete as per drawings and technical specifications Ministry Of Rural Development 2014 Clause 802, 803, 804, 805, 806, 807, 1202 & 1203, 1204 Plain cement concreate grade M 15 Nominal mix (1:2.5:5) And As Directed by Engineer Incharge

386.26

2555669

6616.45

... More
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. B. 1000 milimeter Non pressure 3 Class As per Technical Specification Ministry Of Rural Development 2014 Cluase No. 1100 And As Directed by Engineer Incharge

90

679477

7549.75

... More
Providing and laying reinforced cement concrete pipe Non pressure2 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. D. 600 milimeter Non pressure 2 Class As per Technical Specification Ministry Of Rural Development 2014 Cluase No. 1100 And As Directed by Engineer Incharge

315

860895

2733

... More
Providing weepholes in brick masonry / stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 milimeter dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7 A.C. pipe 100 milimeter Dia And As Directed by Engineer Incharge

20

6068

303.4

... More
Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1303 And As Directed by Engineer Incharge

154.7

341415

2206.95

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per Indian Road Congress:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Ministry Of Rural Development 2014 Clause 1703 Ordinary Kilometer Stone (Precast) And As Directed by Engineer Incharge

4

11895

2973.9

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per Indian Road Congress:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Ministry Of Rural Development 2014 Clause 1703 200 meter stone (precast) And As Directed by Engineer Incharge

16

13344

834.05

... More
Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per Indian Road Congress:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704. And As Directed by Engineer Incharge

419

394446

941.4

... More
MMGSY / PMGSY Citizen' s information Board- Providing and fixing of typical PMGSY Retro Reflective information board as per as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circular and drawing. Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottom duly rivetted with MS angles of 35 x 35 x 5 mm thick M.S angle shall be welded by two vertical M.S angle of 5 mm thick to 75 mm x 75 mm of 12 SWG square tubes / 75mm Dia Pipe posts duly embedded in cement concrete M-20 grade blocks of 600mm x 600mm x 75mm, below ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circular no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4 and as directed by Engineer-In-charge. . A warranty for 5 / 7 years for the Retro reflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor And As Directed by Engineer Incharge.

2

57370

28685

... More
Providing and fixing of typical Mukhya Mantri Gram Sadak Yojana informatory sign board with Logo as per Ministry Of Rural Development specifications and drawing. Three Mild steel Plates of 1.6 mm thick, top and middle plate duly welded with Mild steel flat iron 25Millimeter x 5meter size on back on edges. The lower plate will be welded with Mild steel angle iron frame of 25 Millimeter x 25 Millimeter x 5 Millimeter. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75Millimeter x 75 Millimeter of 12 Steel wire Gause sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450Millimeter x 450Millimeter x 600Millimeter, 600Millimeter below ground level. The top most diamond plate will be welded to middle plate by 47Millimeter x 47Millimeter of 12 Steel wire Gauge steel plate tube. All Mild steel will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 'Logo' of Mukhya Mantri Gram Sadak Yojana Project And As Directed by Engineer Incharge

1

18348

18348.7

... More
Providing and erecting direction and place identification of semi reflective sign boards as per IRC-67 made of 2 mm thick M.S. Sheet duly stove enameled paint white colour in front and grey colour on back with reflective border of 70 mm width and required message, letters, figures with reflective tape of engineering grade as per MORD specifications of required shade and colour. Supported and welded on two nos. 47 mm x 47 mm of 12 SWG square tube of 3050 mm height duly strengthened by 25 mm x 5 mm MS flat iron on edges on back firmly fixed to the ground by means of properly designed foundations with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701 And As Directed by Engineer Incharge

6

24657

4109.5

... More
Providing and fixing Cautionary/Warning sign boards in Equilateral Triangle size of mm made out of mm aluminum sheet bonded with white retro reflective sheeting of Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3 Supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with grey stove enamel paint and supported on one no. of M. S. angle iron post of size 65 mm X 65 mm X 6 mm, 3.45 m long, duly painted with with flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in M25 grade concrete block of size 60cm X 60cm X 75cm including transportation etc; complete. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier. And As Directed by Engineer Incharge

32

122528

3829

... More
Providing and fixing of retro- reflectorised informatory sign board rectangular/Square in shape having area less than 0.9 One Square Meterr made out of mm aluminum sheet bonded with white retro reflective sheeting of Class ( Type IV High intensity micro- prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3, supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with two coats of grey stove enamel paint and supported on one no. mild steel angle iron post 75 mm x 75 mm x 6 mm, 3.5 mt long firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing The angle iron post shall be duly painted with one coat of epoxy primer and two coats of epoxy finish paints having alternate black and white bands of 25 cm width including GI fixures and transportation etc.complete.The nut bolts of board with angle iron post/supporting structure after fixing at site has to be electrically welded. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) sheeting shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier. 600 x 450 milimeter Rectangular And As Directed by Engineer Incharge

2.7

26100

9667

... More
Providing and fixing Mandatory/Regulatory sign boards in circular shape of mm dia made out of mm aluminum sheet bonded with white retro reflective sheeting of Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3 Supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with grey stove enamel paint and supported on one no. of M. S. angle iron post of size 65 mm X 65 mm X 6 mm, 3.45 m long, duly painted with with flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in M25 grade concrete block of size 60cm X 60cm X 75cm including transportation etc; complete. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier. 600mm circular And As Directed by Engineer Incharge

30

135480

4516

... More
Providing and Laying hot applied thermoplastic road marking strip on Bituminous Surface of specified shade/ colour of 2.5 mm thick including 1.5 Refractive index reflectorizing glass beads @ 250gm/sqm .Thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC 35:2015. Initial Dry reflectivity RL shall be 250 mcd/sqm/lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/sqm/ lux and Qd of 100 mcd/sqm/ lux measured at the end of 2 years by means of a Standard Reflectometer of Zehntner, Easylux, Delta make capable of measuring RL & QD both according to IRC 35:2015 clause 15.5. The finished surface to be level, uniform, and free from streaks and holes complete as per direction of Engineer-in-charge and in accordance with applicable specifications.(Refer MORTH Clause 803 for technical Specification and Performance for IRC 35:2015) And As Directed by Engineer Incharge

902

600732

666

... More
Road Delineators: Supplying and installation of delineators (Roadway Indicators, Hazard markers, Object markers) 80 to 100 cm high above ground level, painted black and white in 15cm wide strips, fitted with 80x100mm rectangular or 75mm dia. Circular reflectorised panels at the top, buried or pressed into the ground and confirming to I.R.C. 79 and the drawings And As Directed by Engineer Incharge

37

30414

822

... More
Providing and fixing in position Pipe Railing consisting of IS Rolled steel joist posts designation IS MB 100 (100x75) at 2.5 m interval and three rows of 50 mm dia steel pipes (light) including fixing in position on bridge deck complete as per drawing and technical specifications Clause 1208.2 And As Directed by Engineer Incharge

20

41798

2089.9

... More
Painting two coats including prime coat with epoxy paint of approved brand on concrete/steel surfaces after through cleaning of surface to give an even shade as per drawing and Technical Specification Clause 1701 And As Directed by Engineer Incharge

0.84

138

165.45

... More
White washing two coats on parapet walls and white washing and geru lime painting to tree trunks including preparation of surface by cleaning scraping etc. complete And As Directed by Engineer Incharge

10

260

26

... More
A,W : Metal Beam Crash Barrier (Providing and erecting a "W "metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip cess, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810) And As Directed by Engineer Incharge

50

245600

4912

... More
Providing and Laying of 2 or more sets (6Nos. each set) Dual Ribs Pattern Rumble Markings on roads with vehicular speeds of more than 50 Km/hr laid as per the spacing recommended for each set under Table11.1 and Fig.11.2 of IRC35:2015 using Plastirib 2K, or equivalent 2 component cold plastic profiled material. Each Dual Rib pattern rumble marking shall have width of 500mm. Each dual rib pattern rumble marking shall have 2 ribs each of Width of 100mm and height 20mm. Gap between two ribs shall be 300mm. Each rumble marking shall be made complete with drop on Soild Plus reflective glass beads @ 300 gm / One Square Metre spread throughout the surface of marking. The finished surface to be levelled,uniform and free from streaks and holes,including surface cleaning and cost of all materials etc. complete. And As Directed by Engineer Incharge.

6

25998

4333

... More
C) Improvement of Road from Gomewadi to Hivtad Shukracharya Road Ch 0/000 to 3/420, Taluka -Atpadi, District:-Sangli, Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 milimeter, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 meter including removal and disposal of top organic soil not exceeding 150 milimeter in thickness as per Technical Specification Ministry Of Rural Development 2014 Clause 201. By mechnical means (A) In area Non of thorny jungle And As Directed by Engineer Incharge

1.03

28693

27857.35

... More
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 milimeter, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 meter including removal and disposal of top organic soil not exceeding 150 milimeter in thickness as per Technical Specification Ministry Of Rural Development 2014 Clause 201.By mechnical means (B) In area of thorny jungle And As Directed by Engineer Incharge

0.69

23893

34627.65

... More
Excavation for roadwork in soil with hydraulic excavator of 0.9 cubicmeter bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with a lift upto 1.5 meter and lead more than 100 meter as per Technical Specification Ministry Of Rural Development 2014 Clause 302.3 And As Directed by Engineer Incharge

2582

200492

77.65

... More
Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cubicmeter bucket capacity including cutting and loading in tippers, transporting to embankment site with a lift upto 1.5 meter and lead above 100 meter, trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections as per Technical Specification Ministry Of Rural Development 2014 Clause 302.3.5 And As Directed by Engineer Incharge

790.05

90144

114.1

... More
Excavation for roadway in hard rock (requiring blasting) by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross-sections, loading and disposal of cut rock with a lift upto 1.5 meter and leads upto 1000 meter as per Technical Specification Clause 302.3.5 And As Directed by Engineer Incharge

48.28

7630

158.05

... More
Scarifying existing bituminous surface to a depth of 150 mm and disposal of scarified material with a lift upto 3 m and leads upto 1000 m as per Technical Specification Clause 301.4. as per Technical Specification Clause 301.4 And As Directed by Engineer Incharge

10350

171810

16.6

... More
Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Ministry Of Rural Development 2014 Clause 301.5 And As Directed by Engineer Incharge

1511.63

133099

88.05

... More
Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 And As Directed by Engineer Incharge

2429.04

1202131

494.9

... More
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 as per Technical Specification Ministry Of Rural Development 2014 Clause 303.1. And As Directed by Engineer Incharge

2515.73

1503149

597.5

... More
Loosening, Levelling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 milimeter, mixed with water at optimum moisture content and then compacted by rolling so as to achieve minimum dry density as given in Tables 300.1 and 300.2 for embankment construction as per Technical Specification Clause 301.4.1.And As Directed by Engineer Incharge And As Directed by Engineer Incharge

120

4146

34.55

... More
Setting Out And As Directed by Engineer Incharge

3.42

89432

26149.8

... More
Construction of Granular sub-base grade -II by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator and compacting with vibretary wheel roller to achieve the desired density, complete as per Technical Specification Ministry Of Rural Development 2014 Clause 401. And As Directed by Engineer Incharge

520.8

1145421

2199.35

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kilonewton static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Water bound macadum Grading 2 as per Technical Specification Ministry Of Rural Development 2014 Clause 405. For - By Mechanical Means And As Directed by Engineer Incharge

339.4

799575

2355.85

... More
Providing and laying White Topping/Short Paneled Concrete as per IRC-SP 76-2015 (Existing surface preparation to be done if necessary either by milling or leveling course with DLC to correct surface profile and to be paid separately) with un reinforced M-40 grade Pavement Quality Concrete using Ordinary Portland Cement 43/53 Grade OR Portland Pozzolona Cement IS-1489 at 425kg/cum, coarse aggregate, fine aggregate(VSI) and Admixture confirming to IS 9130-1999 (R-2004) polymeric synthetic fiber as per ASTM (1116) such as polyester / polyethylene / polypropylene / Glass fiber at 1.20 kg/cum, mixed in batching and mixing plant or weigh batcher as per approved mix design to achieve minimum flexural strength or modulus of rupture of concrete 4.50 MPa at 28 days limiting maximum water cement ratio to 0.40, transported to site, laid with fixed form/ slip form paver finisher (preferably with slip form paver finisher), spread, vibrated, compacted and finished in a continuous operation to the lines and grades as per drawing, texture finishing of surface, spraying two layers of curing compound, curing with water sprayed on hessian cloth covered over concrete surface, groove cutting grid 1m x 1m or as directed by Engineer Incharge to a depth of 1/3 to 1/4 of the Thickness and of width 3-5 mm as per design including cost of all material, side form work, labour and machineries etc. complete as per specifications.(Excluding Dowel Bars and Tie Bars) ( Including Polythene sheet 125 micron) And As Directed by Engineer Incharge

2055.07

16195390

7880.7

... More
Providing & Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to 15: 383, the size of coarse aggregate not exceeding 25 mm, , cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days,mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts,laid with a paver with electronic sensor /by suitable means as approved by Engineer-in charge , compacting with vibratory roller, finishing, curing and including preparation of sub-grade surface if required etc. complete And As Directed by Engineer Incharge.

1470.81

5403241

3673.65

... More
Providing and fixing in position 25mm dia anti corrosive MS dowel bars of required Dia. 60 cms. Long and at 30.00cm C/C and wherever directed including handling, straightening, necessary cutting supported by chairs with proper alignment with half length covered by polyethene sheathhing including cap etc. cpmpleted And As Directed by Engineer Incharge.

442

107781

243.85

... More
Providing and fixing in position anticorrosive TMT FE 500 tie bars of 12mm dia. 70cms long and 30.00cm. C/C and wherever directed including handling, straightening, necessary cutting, handling, straightening, supported by assembly of TMT FE 500, Chairs with proper alignement etc. completed. And As Directed by Engineer Incharge

11850

789802

66.65

... More
Dismantling Stone Masonry as per Technical Specification MORD 2014 Clause 202. Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification MORD 2014 Clause 202. Rubble Stone Masonry in Cement Mortar And As Directed by Engineer Incharge

142.75

90060

630.9

... More
Removing all types of Hume pipes and stacking within a lead of 1000 m including Earthwork and Dismantling of Masonry Works as per Technical Specification MORD 2014 Clause 202. Upto 600 mm dia Hume pipe And As Directed by Engineer Incharge

60

37050

617.5

... More
Earthwork in excavation for structures as per drawing and technical specifications Ministry Of Rural Development 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 meter, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary soil And As Directed by Engineer Incharge

762.85

536855

703.75

... More
Earthwork in excavation for structures as per drawing and technical specifications Ministry Of Rural Development 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 meter, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary rock (not requiring blasting) Upto 3 meter depth And As Directed by Engineer Incharge

200.55

176423

879.7

... More
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Hard rock (blasting prohibited) Upto 3 meter depth And As Directed by Engineer Incharge

55.3

68397

1236.85

... More
Filling in foundation trenches as per drawing and technical specification Clause 305.3.9 Rubble soling with Rubble And As Directed by Engineer Incharge

66.97

157252

2348.1

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 Plane cement concreate grade M 10 Nominal mix 1:3:6 And As Directed by Engineer Incharge

165.26

1082453

6550

... More
Providing concrete for plain/reinforced concrete in sub structure complete as per drawings and technical specifications Ministry Of Rural Development 2014 Clause 802, 803, 804, 805, 806, 807, 1202 & 1203, 1204 Plain cement concreate grade M 15 Nominal mix (1:2.5:5) And As Directed by Engineer Incharge

683.1

4657956

6818.85

... More
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. B. 1000 milimeter Non pressure 3 Class As per Technical Specification Ministry Of Rural Development 2014 Cluase No. 1100 And As Directed by Engineer Incharge

105

832361

7927.25

... More
Providing and laying reinforced cement concrete pipe Non pressure2 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. D. 600 milimeter Non pressure 2 Class As per Technical Specification Ministry Of Rural Development 2014 Cluase No. 1100 And As Directed by Engineer Incharge

270

774805

2869.65

... More
Supplying, fitting, and placing TMT bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202 And As Directed by Engineer Incharge

0.17

14588

85812.8

... More
Supplying, fitting and placing TMT bar reinforcement (Fe 415) in sub structure complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202 And As Directed by Engineer Incharge

4.67

389277

83357

... More
Providing weepholes in brick masonry / stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 milimeter dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7 A.C. pipe 100 milimeter Dia And As Directed by Engineer Incharge

20

6372

318.6

... More
Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1303 And As Directed by Engineer Incharge

139.23

306584

2202

... More
Providing groove to required size at specified location as directed by Engineer, at junction of brick masonry wall and R.C.C beams or Column, at junction of composite masonry, including scaffolding, finishing, curing etc. Complete And As Directed by Engineer Incharge

54.17

2811

51.9

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per Indian Road Congress:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Ministry Of Rural Development 2014 Clause 1703 Ordinary Kilometer Stone (Precast) And As Directed by Engineer Incharge

4

12490

3122.6

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per Indian Road Congress:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Ministry Of Rural Development 2014 Clause 1703 200 meter stone (precast) And As Directed by Engineer Incharge

14

12260

875.75

... More
Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per Indian Road Congress:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704. And As Directed by Engineer Incharge

326

287662

882.4

... More
MMGSY / PMGSY Citizen' s information Board- Providing and fixing of typical PMGSY Retro Reflective information board as per as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circular and drawing. Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottom duly rivetted with MS angles of 35 x 35 x 5 mm thick M.S angle shall be welded by two vertical M.S angle of 5 mm thick to 75 mm x 75 mm of 12 SWG square tubes / 75mm Dia Pipe posts duly embedded in cement concrete M-20 grade blocks of 600mm x 600mm x 75mm, below ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circular no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4 and as directed by Engineer-In-charge. . A warranty for 5 / 7 years for the Retro reflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor And As Directed by Engineer Incharge.

2

60238

30119.25

... More
Providing and fixing of typical Mukhya Mantri Gram Sadak Yojana informatory sign board with Logo as per Ministry Of Rural Development specifications and drawing. Three Mild steel Plates of 1.6 mm thick, top and middle plate duly welded with Mild steel flat iron 25Millimeter x 5meter size on back on edges. The lower plate will be welded with Mild steel angle iron frame of 25 Millimeter x 25 Millimeter x 5 Millimeter. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75Millimeter x 75 Millimeter of 12 Steel wire Gause sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450Millimeter x 450Millimeter x 600Millimeter, 600Millimeter below ground level. The top most diamond plate will be welded to middle plate by 47Millimeter x 47Millimeter of 12 Steel wire Gauge steel plate tube. All Mild steel will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 'Logo' of Mukhya Mantri Gram Sadak Yojana Project And As Directed by Engineer Incharge

1

19266

19266.15

... More
Providing and erecting direction and place identification of semi reflective sign boards as per IRC-67 made of 2 mm thick M.S. Sheet duly stove enameled paint white colour in front and grey colour on back with reflective border of 70 mm width and required message, letters, figures with reflective tape of engineering grade as per MORD specifications of required shade and colour. Supported and welded on two nos. 47 mm x 47 mm of 12 SWG square tube of 3050 mm height duly strengthened by 25 mm x 5 mm MS flat iron on edges on back firmly fixed to the ground by means of properly designed foundations with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701 And As Directed by Engineer Incharge

10

43149

4314.95

... More
Providing and fixing Cautionary/Warning sign boards in Equilateral Triangle size of mm made out of mm aluminum sheet bonded with white retro reflective sheeting of Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3 Supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with grey stove enamel paint and supported on one no. of M. S. angle iron post of size 65 mm X 65 mm X 6 mm, 3.45 m long, duly painted with with flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in M25 grade concrete block of size 60cm X 60cm X 75cm including transportation etc; complete. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier. And As Directed by Engineer Incharge

34

136695

4020.45

... More
Providing and fixing of retro- reflectorised informatory sign board rectangular/Square in shape having area less than 0.9 One Square Meterr made out of mm aluminum sheet bonded with white retro reflective sheeting of Class ( Type IV High intensity micro- prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3, supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with two coats of grey stove enamel paint and supported on one no. mild steel angle iron post 75 mm x 75 mm x 6 mm, 3.5 mt long firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing The angle iron post shall be duly painted with one coat of epoxy primer and two coats of epoxy finish paints having alternate black and white bands of 25 cm width including GI fixures and transportation etc.complete.The nut bolts of board with angle iron post/supporting structure after fixing at site has to be electrically welded. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) sheeting shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier. 600 x 450 milimeter Rectangular And As Directed by Engineer Incharge

2.16

21924

10150.35

... More
Providing and fixing Mandatory/Regulatory sign boards in circular shape of mm dia made out of mm aluminum sheet bonded with white retro reflective sheeting of Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3 Supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with grey stove enamel paint and supported on one no. of M. S. angle iron post of size 65 mm X 65 mm X 6 mm, 3.45 m long, duly painted with with flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in M25 grade concrete block of size 60cm X 60cm X 75cm including transportation etc; complete. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier. 600mm circular And As Directed by Engineer Incharge

36

170704

4741.8

... More
Providing and Laying hot applied thermoplastic road marking strip on Bituminous Surface of specified shade/ colour of 2.5 mm thick including 1.5 Refractive index reflectorizing glass beads @ 250gm/sqm .Thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC 35:2015. Initial Dry reflectivity RL shall be 250 mcd/sqm/lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/sqm/ lux and Qd of 100 mcd/sqm/ lux measured at the end of 2 years by means of a Standard Reflectometer of Zehntner, Easylux, Delta make capable of measuring RL & QD both according to IRC 35:2015 clause 15.5. The finished surface to be level, uniform, and free from streaks and holes complete as per direction of Engineer-in-charge and in accordance with applicable specifications.(Refer MORTH Clause 803 for technical Specification and Performance for IRC 35:2015) And As Directed by Engineer Incharge

690

482517

699.3

... More
Road Delineators: Supplying and installation of delineators (Roadway Indicators, Hazard markers, Object markers) 80 to 100 cm high above ground level, painted black and white in 15cm wide strips, fitted with 80x100mm rectangular or 75mm dia. Circular reflectorised panels at the top, buried or pressed into the ground and confirming to I.R.C. 79 and the drawings And As Directed by Engineer Incharge

52

44881

863.1

... More
Providing and fixing in position Pipe Railing consisting of IS Rolled steel joist posts designation IS MB 100 (100x75) at 2.5 m interval and three rows of 50 mm dia steel pipes (light) including fixing in position on bridge deck complete as per drawing and technical specifications Clause 1208.2 And As Directed by Engineer Incharge

50

109720

2194.4

... More
Painting two coats including prime coat with epoxy paint of approved brand on concrete/steel surfaces after through cleaning of surface to give an even shade as per drawing and Technical Specification Clause 1701 And As Directed by Engineer Incharge

3

521

173.75

... More
White washing two coats on parapet walls and white washing and geru lime painting to tree trunks including preparation of surface by cleaning scraping etc. complete And As Directed by Engineer Incharge

10

273

27.3

... More
A,W : Metal Beam Crash Barrier (Providing and erecting a "W "metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip cess, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810) And As Directed by Engineer Incharge

250

1289400

5157.6

... More
Providing and Laying of 2 or more sets (6Nos. each set) Dual Ribs Pattern Rumble Markings on roads with vehicular speeds of more than 50 Km/hr laid as per the spacing recommended for each set under Table11.1 and Fig.11.2 of IRC35:2015 using Plastirib 2K, or equivalent 2 component cold plastic profiled material. Each Dual Rib pattern rumble marking shall have width of 500mm. Each dual rib pattern rumble marking shall have 2 ribs each of Width of 100mm and height 20mm. Gap between two ribs shall be 300mm. Each rumble marking shall be made complete with drop on Soild Plus reflective glass beads @ 300 gm / One Square Metre spread throughout the surface of marking. The finished surface to be levelled,uniform and free from streaks and holes,including surface cleaning and cost of all materials etc. complete. And As Directed by Engineer Incharge.

6

27297

4549.65

... More
D) Improvement Of Road From Ghanwad To (Bhagyanagar ) Bhakuchiwadi Road Ch 0/000 to 3/910, Taluka -Khanapur , District:-Sangli, Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 milimeter, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 meter including removal and disposal of top organic soil not exceeding 150 milimeter in thickness as per Technical Specification Ministry Of Rural Development 2014 Clause 201. By mechnical means (A) In area Non of thorny jungle And As Directed by Engineer Incharge

1.18

32871

27857.35

... More
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 milimeter, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 meter including removal and disposal of top organic soil not exceeding 150 milimeter in thickness as per Technical Specification Ministry Of Rural Development 2014 Clause 201.By mechnical means (B) In area of thorny jungle And As Directed by Engineer Incharge

0.79

27355

34627.65

... More
Excavation for roadwork in soil with hydraulic excavator of 0.9 cubicmeter bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with a lift upto 1.5 meter and lead more than 100 meter as per Technical Specification Ministry Of Rural Development 2014 Clause 302.3 And As Directed by Engineer Incharge

6045.44

469428

77.65

... More
Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cubicmeter bucket capacity including cutting and loading in tippers, transporting to embankment site with a lift upto 1.5 meter and lead above 100 meter, trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections as per Technical Specification Ministry Of Rural Development 2014 Clause 302.3.5 And As Directed by Engineer Incharge

1211.72

138257

114.1

... More
Excavation for roadway in hard rock (requiring blasting) by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross-sections, loading and disposal of cut rock with a lift upto 1.5 meter and leads upto 1000 meter as per Technical Specification Clause 302.3.5 And As Directed by Engineer Incharge

115.4

18238

158.05

... More
Scarifying existing bituminous surface to a depth of 150 mm and disposal of scarified material with a lift upto 3 m and leads upto 1000 m as per Technical Specification Clause 301.4. as per Technical Specification Clause 301.4 And As Directed by Engineer Incharge

11730

194718

16.6

... More
Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Ministry Of Rural Development 2014 Clause 301.5 And As Directed by Engineer Incharge

2662.52

234434

88.05

... More
Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 And As Directed by Engineer Incharge

3720.6

2329281

626.05

... More
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 as per Technical Specification Ministry Of Rural Development 2014 Clause 303.1. And As Directed by Engineer Incharge

2538.96

1864612

734.4

... More
Setting Out And As Directed by Engineer Incharge

3.91

101872

26054.31

... More
Construction of Granular sub-base grade -II by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator and compacting with vibretary wheel roller to achieve the desired density, complete as per Technical Specification Ministry Of Rural Development 2014 Clause 401. And As Directed by Engineer Incharge

1546.06

3300528

2134.8

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kilonewton static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Water bound macadum Grading 2 as per Technical Specification Ministry Of Rural Development 2014 Clause 405. For - By Mechanical Means And As Directed by Engineer Incharge

845.19

1959234

2318.1

... More
Providing and laying White Topping/Short Paneled Concrete as per IRC-SP 76-2015 (Existing surface preparation to be done if necessary either by milling or leveling course with DLC to correct surface profile and to be paid separately) with un reinforced M-40 grade Pavement Quality Concrete using Ordinary Portland Cement 43/53 Grade OR Portland Pozzolona Cement IS-1489 at 425kg/cum, coarse aggregate, fine aggregate(VSI) and Admixture confirming to IS 9130-1999 (R-2004) polymeric synthetic fiber as per ASTM (1116) such as polyester / polyethylene / polypropylene / Glass fiber at 1.20 kg/cum, mixed in batching and mixing plant or weigh batcher as per approved mix design to achieve minimum flexural strength or modulus of rupture of concrete 4.50 MPa at 28 days limiting maximum water cement ratio to 0.40, transported to site, laid with fixed form/ slip form paver finisher (preferably with slip form paver finisher), spread, vibrated, compacted and finished in a continuous operation to the lines and grades as per drawing, texture finishing of surface, spraying two layers of curing compound, curing with water sprayed on hessian cloth covered over concrete surface, groove cutting grid 1m x 1m or as directed by Engineer Incharge to a depth of 1/3 to 1/4 of the Thickness and of width 3-5 mm as per design including cost of all material, side form work, labour and machineries etc. complete as per specifications.(Excluding Dowel Bars and Tie Bars) ( Including Polythene sheet 125 micron) And As Directed by Engineer Incharge

3829.67

29944381

7819.05

... More
Providing & Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate ( natural sand/ VSI grade finely washed crushed sand) conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, , cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days,mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts,laid with a paver with electronic sensor /by suitable means as approved by Engineer-in charge , compacting with vibratory roller, finishing, curing and including preparation of sub-grade surface if required etc. complete. And As Directed by Engineer Incharge

2374.78

8306861

3497.95

... More
Providing and fixing in position 25mm dia anti corrosive MS dowel bars of required Dia. 60 cms. Long and at 30.00 cm. C/C and wherever directed including handling. straightening, necessary cutting supported by chairs with proper alignment with half length covered by polyethene sheathing including cap etc. complete.And As Directed by Engineer Incharge

684

166827

243.9

... More
Providing and fixing in position anticorrosive TMT FE 500 tie bars of 12 mm dia. 70 cms. long and at 30.00 cm. C/C and wherever directed including handling, straightening necessary cutting, handling, straightening, supported by assembly of TMT FE 500, chairs with proper alignment etc. complete.And As Directed by Engineer Incharge

39295

2619011

66.65

... More
Dismantling Stone Masonry as per Technical Specification MORD 2014 Clause 202. Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification MORD 2014 Clause 202. Rubble Stone Masonry in Cement Mortar And As Directed by Engineer Incharge

78.75

49683

630.9

... More
Removing all types of Hume pipes and stacking within a lead of 1000 m including Earthwork and Dismantling of Masonry Works as per Technical Specification MORD 2014 Clause 202. Upto 600 mm dia Hume pipe And As Directed by Engineer Incharge

22.5

13893

617.5

... More
Earthwork in excavation for structures as per drawing and technical specifications Ministry Of Rural Development 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 meter, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary soil And As Directed by Engineer Incharge

577.66

406528

703.75

... More
Earthwork in excavation for structures as per drawing and technical specifications Ministry Of Rural Development 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 meter, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary rock (not requiring blasting) Upto 3 meter depth And As Directed by Engineer Incharge

148.77

129928

873.35

... More
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Hard rock (blasting prohibited) Upto 3 meter depth And As Directed by Engineer Incharge

21.55

26654

1236.85

... More
Filling in foundation trenches as per drawing and technical specification Clause 305.3.9 Rubble soling with Rubble And As Directed by Engineer Incharge

17.64

41420

2348.1

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 Plane cement concreate grade M 10 Nominal mix 1:3:6 And As Directed by Engineer Incharge

90.37

585710

6481.25

... More
Providing concrete for plain/reinforced concrete in sub structure complete as per drawings and technical specifications Ministry Of Rural Development 2014 Clause 802, 803, 804, 805, 806, 807, 1202 & 1203, 1204 Plain cement concreate grade M 15 Nominal mix (1:2.5:5) And As Directed by Engineer Incharge

490.52

3315130

6758.4

... More
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. B. 1000 milimeter Non pressure 3 Class As per Technical Specification Ministry Of Rural Development 2014 Cluase No. 1100 And As Directed by Engineer Incharge

51.15

430012

8406.9

... More
Providing and laying reinforced cement concrete pipe Non pressure2 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. D. 600 milimeter Non pressure 2 Class As per Technical Specification Ministry Of Rural Development 2014 Cluase No. 1100 And As Directed by Engineer Incharge

277.5

796327

2869.65

... More
Supplying, fitting and placing TMT bar reinforcement (Fe 415) in sub structure complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202 And As Directed by Engineer Incharge

4.31

359307

83365.9

... More
Providing weepholes in brick masonry / stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 milimeter dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7 A.C. pipe 100 milimeter Dia And As Directed by Engineer Incharge

50

15930

318.6

... More
Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1303 And As Directed by Engineer Incharge

124.88

267393

2141.2

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per Indian Road Congress:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Ministry Of Rural Development 2014 Clause 1703 Ordinary Kilometer Stone (Precast) And As Directed by Engineer Incharge

4

12490

3122.6

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per Indian Road Congress:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Ministry Of Rural Development 2014 Clause 1703 200 meter stone (precast) And As Directed by Engineer Incharge

16

14012

875.75

... More
Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per Indian Road Congress:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704. And As Directed by Engineer Incharge

365

322076

882.4

... More
MMGSY / PMGSY Citizen' s information Board- Providing and fixing of typical PMGSY Retro Reflective information board as per as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circular and drawing. Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottom duly rivetted with MS angles of 35 x 35 x 5 mm thick M.S angle shall be welded by two vertical M.S angle of 5 mm thick to 75 mm x 75 mm of 12 SWG square tubes / 75mm Dia Pipe posts duly embedded in cement concrete M-20 grade blocks of 600mm x 600mm x 75mm, below ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circular no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4 and as directed by Engineer-In-charge. . A warranty for 5 / 7 years for the Retro reflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor.And As Directed by Engineer Incharge

2

60238

30119.25

... More
Providing and fixing of typical Mukhya Mantri Gram Sadak Yojana informatory sign board with Logo as per Ministry Of Rural Development specifications and drawing. Three Mild steel Plates of 1.6 mm thick, top and middle plate duly welded with Mild steel flat iron 25Millimeter x 5meter size on back on edges. The lower plate will be welded with Mild steel angle iron frame of 25 Millimeter x 25 Millimeter x 5 Millimeter. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75Millimeter x 75 Millimeter of 12 Steel wire Gause sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450Millimeter x 450Millimeter x 600Millimeter, 600Millimeter below ground level. The top most diamond plate will be welded to middle plate by 47Millimeter x 47Millimeter of 12 Steel wire Gauge steel plate tube. All Mild steel will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 'Logo' of Mukhya Mantri Gram Sadak Yojana Project And As Directed by Engineer Incharge

2

38532

19266.1

... More
Providing and erecting direction and place identification of semi reflective sign boards as per IRC-67 made of 2 mm thick M.S. Sheet duly stove enameled paint white colour in front and grey colour on back with reflective border of 70 mm width and required message, letters, figures with reflective tape of engineering grade as per MORD specifications of required shade and colour. Supported and welded on two nos. 47 mm x 47 mm of 12 SWG square tube of 3050 mm height duly strengthened by 25 mm x 5 mm MS flat iron on edges on back firmly fixed to the ground by means of properly designed foundations with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701 And As Directed by Engineer Incharge

8

34519

4314.95

... More
Providing and fixing Cautionary/Warning sign boards in Equilateral Triangle size of mm made out of mm aluminum sheet bonded with white retro reflective sheeting of Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3 Supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with grey stove enamel paint and supported on one no. of M. S. angle iron post of size 65 mm X 65 mm X 6 mm, 3.45 m long, duly painted with with flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in M25 grade concrete block of size 60cm X 60cm X 75cm including transportation etc; complete. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier. And As Directed by Engineer Incharge

30

120613

4020.45

... More
Providing and fixing of retro- reflectorised informatory sign board rectangular/Square in shape having area less than 0.9 One Square Meterr made out of mm aluminum sheet bonded with white retro reflective sheeting of Class ( Type IV High intensity micro- prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3, supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with two coats of grey stove enamel paint and supported on one no. mild steel angle iron post 75 mm x 75 mm x 6 mm, 3.5 mt long firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing The angle iron post shall be duly painted with one coat of epoxy primer and two coats of epoxy finish paints having alternate black and white bands of 25 cm width including GI fixures and transportation etc.complete.The nut bolts of board with angle iron post/supporting structure after fixing at site has to be electrically welded. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) sheeting shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier. 600 x 450 milimeter Rectangular And As Directed by Engineer Incharge

2.43

24665

10150.35

... More
Providing and fixing Mandatory/Regulatory sign boards in circular shape of mm dia made out of mm aluminum sheet bonded with white retro reflective sheeting of Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3 Supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with grey stove enamel paint and supported on one no. of M. S. angle iron post of size 65 mm X 65 mm X 6 mm, 3.45 m long, duly painted with with flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in M25 grade concrete block of size 60cm X 60cm X 75cm including transportation etc; complete. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier. 600mm circular And As Directed by Engineer Incharge

28

132770

4741.8

... More
Providing and Laying hot applied thermoplastic road marking strip on Bituminous Surface of specified shade/ colour of 2.5 mm thick including 1.5 Refractive index reflectorizing glass beads @ 250gm/sqm .Thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC 35:2015. Initial Dry reflectivity RL shall be 250 mcd/sqm/lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/sqm/ lux and Qd of 100 mcd/sqm/ lux measured at the end of 2 years by means of a Standard Reflectometer of Zehntner, Easylux, Delta make capable of measuring RL & QD both according to IRC 35:2015 clause 15.5. The finished surface to be level, uniform, and free from streaks and holes complete as per direction of Engineer-in-charge and in accordance with applicable specifications.(Refer MORTH Clause 803 for technical Specification and Performance for IRC 35:2015)

792.5

554195

699.3

... More
Road Delineators: Supplying and installation of delineators (Roadway Indicators, Hazard markers, Object markers) 80 to 100 cm high above ground level, painted black and white in 15cm wide strips, fitted with 80x100mm rectangular or 75mm dia. Circular reflectorised panels at the top, buried or pressed into the ground and confirming to I.R.C. 79 and the drawings And As Directed by Engineer Incharge

38

32797

863.1

... More
Providing and fixing in position Pipe Railing consisting of IS Rolled steel joist posts designation IS MB 100 (100x75) at 2.5 m interval and three rows of 50 mm dia steel pipes (light) including fixing in position on bridge deck complete as per drawing and technical specifications Clause 1208.2 And As Directed by Engineer Incharge

50

109720

2194.4

... More
Painting two coats including prime coat with epoxy paint of approved brand on concrete/steel surfaces after through cleaning of surface to give an even shade as per drawing and Technical Specification Clause 1701 And As Directed by Engineer Incharge

2.04

354

173.75

... More
White washing two coats on parapet walls and white washing and geru lime painting to tree trunks including preparation of surface by cleaning scraping etc. complete And As Directed by Engineer Incharge

17

464

27.3

... More
A,W : Metal Beam Crash Barrier (Providing and erecting a "W "metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip cess, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810) And As Directed by Engineer Incharge

120

618912

5157.6

... More
Providing and Laying of 2 or more sets (6Nos. each set) Dual Ribs Pattern Rumble Markings on roads with vehicular speeds of more than 50 Km/hr laid as per the spacing recommended for each set under Table11.1 and Fig.11.2 of IRC35:2015 using Plastirib 2K, or equivalent 2 component cold plastic profiled material. Each Dual Rib pattern rumble marking shall have width of 500mm. Each dual rib pattern rumble marking shall have 2 ribs each of Width of 100mm and height 20mm. Gap between two ribs shall be 300mm. Each rumble marking shall be made complete with drop on Soild Plus reflective glass beads @ 300 gm / One Square Metre spread throughout the surface of marking. The finished surface to be levelled,uniform and free from streaks and holes,including surface cleaning and cost of all materials etc. complete. And As Directed by Engineer Incharge.

10.5

47771

4549.65

... More
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. And As Directed by Engineer Incharge

171

116690

682.4

... More
Providing groove to required size at specified location as directed by Engineer, at junction of brick masonry wall and R.C.C beams or Column, at junction of composite masonry, including scaffolding, finishing, curing etc. Complete

51.3

2480

48.35

... More
Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete And As Directed by Engineer Incharge

47.25

2827

59.85

... More
E) Improvement of Road from Nagewadi To Godachiwadi ( Kanharwadi Dist. Border) Road Ch 0/000 To 4/100, Taluka -Khanapur, District:-Sangli, Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 milimeter, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 meter including removal and disposal of top organic soil not exceeding 150 milimeter in thickness as per Technical Specification Ministry Of Rural Development 2014 Clause 201. By mechnical means (A) In area Non of thorny jungle And As Directed by Engineer Incharge

1.23

34264

27857.35

... More
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 milimeter, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 meter including removal and disposal of top organic soil not exceeding 150 milimeter in thickness as per Technical Specification Ministry Of Rural Development 2014 Clause 201.By mechnical means (B) In area of thorny jungle And As Directed by Engineer Incharge

0.82

28394

34627.65

... More
Excavation for roadwork in soil with hydraulic excavator of 0.9 cubicmeter bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with a lift upto 1.5 meter and lead more than 100 meter as per Technical Specification Ministry Of Rural Development 2014 Clause 302.3 And As Directed by Engineer Incharge

3461.36

268774

77.65

... More
Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cubicmeter bucket capacity including cutting and loading in tippers, transporting to embankment site with a lift upto 1.5 meter and lead above 100 meter, trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections as per Technical Specification Ministry Of Rural Development 2014 Clause 302.3.5 And As Directed by Engineer Incharge

1210.47

138114

114.1

... More
Excavation for roadway in hard rock (requiring blasting) by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross-sections, loading and disposal of cut rock with a lift upto 1.5 meter and leads upto 1000 meter as per Technical Specification Clause 302.3.5 And As Directed by Engineer Incharge

49.28

7788

158.05

... More
Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal with a lift upto 1.5 meter and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification Clause 302.3.5 And As Directed by Engineer Incharge

21.12

11669

552.55

... More
Scarifying existing bituminous surface to a depth of 150 mm and disposal of scarified material with a lift upto 3 m and leads upto 1000 m as per Technical Specification Clause 301.4. as per Technical Specification Clause 301.4 And As Directed by Engineer Incharge

9187.5

152512

16.6

... More
Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Ministry Of Rural Development 2014 Clause 301.5 And As Directed by Engineer Incharge

1973.14

173734

88.05

... More
Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 And As Directed by Engineer Incharge

1554.92

973457

626.05

... More
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 as per Technical Specification Ministry Of Rural Development 2014 Clause 303.1. And As Directed by Engineer Incharge

2707.83

1988631

734.4

... More
Setting Out And As Directed by Engineer Incharge

4.1

107398

26194.77

... More
Construction of Granular sub-base grade -II by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator and compacting with vibretary wheel roller to achieve the desired density, complete as per Technical Specification Ministry Of Rural Development 2014 Clause 401. And As Directed by Engineer Incharge

243.41

551080

2264

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kilonewton static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Water bound macadum Grading 2 as per Technical Specification Ministry Of Rural Development 2014 Clause 405. For - By Mechanical Means And As Directed by Engineer Incharge

213.6

521354

2440.8

... More
Providing and laying White Topping/Short Paneled Concrete as per IRC-SP 76-2015 (Existing surface preparation to be done if necessary either by milling or leveling course with DLC to correct surface profile and to be paid separately) with un reinforced M-40 grade Pavement Quality Concrete using Ordinary Portland Cement 43/53 Grade OR Portland Pozzolona Cement IS-1489 at 425kg/cum, coarse aggregate, fine aggregate(VSI) and Admixture confirming to IS 9130-1999 (R-2004) polymeric synthetic fiber as per ASTM (1116) such as polyester / polyethylene / polypropylene / Glass fiber at 1.20 kg/cum, mixed in batching and mixing plant or weigh batcher as per approved mix design to achieve minimum flexural strength or modulus of rupture of concrete 4.50 MPa at 28 days limiting maximum water cement ratio to 0.40, transported to site, laid with fixed form/ slip form paver finisher (preferably with slip form paver finisher), spread, vibrated, compacted and finished in a continuous operation to the lines and grades as per drawing, texture finishing of surface, spraying two layers of curing compound, curing with water sprayed on hessian cloth covered over concrete surface, groove cutting grid 1m x 1m or as directed by Engineer Incharge to a depth of 1/3 to 1/4 of the Thickness and of width 3-5 mm as per design including cost of all material, side form work, labour and machineries etc. complete as per specifications.(Excluding Dowel Bars and Tie Bars) ( Including Polythene sheet 125 micron) And As Directed by Engineer Incharge

2399.65

19076497

7949.7

... More
Providing & Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate ( natural sand/ VSI grade finely washed crushed sand) conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, , cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days,mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts,laid with a paver with electronic sensor /by suitable means as approved by Engineer-in charge , compacting with vibratory roller, finishing, curing and including preparation of sub-grade surface if required etc. complete. And As Directed by Engineer Incharge

1144.09

4280555

3741.45

... More
Providing and fixing in position 25mm dia anti corrosive MS dowel bars of required Dia. 60 cms. Long and at 30.00 cm. C/C and wherever directed including handling. straightening, necessary cutting supported by chairs with proper alignment with half length covered by polyethene sheathing including cap etc. complete.And As Directed by Engineer Incharge

492

119998

243.9

... More
Providing and fixing in position anticorrosive TMT FE 500 tie bars of 12 mm dia. 70 cms. long and at 30.00 cm. C/C and wherever directed including handling, straightening necessary cutting, handling, straightening, supported by assembly of TMT FE 500, chairs with proper alignment etc. complete.And As Directed by Engineer Incharge

13748

916304

66.65

... More
Dismantling Stone Masonry as per Technical Specification MORD 2014 Clause 202. Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification MORD 2014 Clause 202. Rubble Stone Masonry in Cement Mortar And As Directed by Engineer Incharge

46.26

29185

630.9

... More
Removing all types of Hume pipes and stacking within a lead of 1000 m including Earthwork and Dismantling of Masonry Works as per Technical Specification MORD 2014 Clause 202. Upto 600 mm dia Hume pipe And As Directed by Engineer Incharge

15

9262

617.5

... More
Earthwork in excavation for structures as per drawing and technical specifications Ministry Of Rural Development 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 meter, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary soil And As Directed by Engineer Incharge

264.7

186282

703.75

... More
Earthwork in excavation for structures as per drawing and technical specifications Ministry Of Rural Development 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 meter, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary rock (not requiring blasting) Upto 3 meter depth And As Directed by Engineer Incharge

150.36

132271

879.7

... More
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Hard rock (blasting prohibited) Upto 3 meter depth And As Directed by Engineer Incharge

41.54

51378

1236.85

... More
Filling in foundation trenches as per drawing and technical specification Clause 305.3.9 Rubble soling with Rubble And As Directed by Engineer Incharge

7.64

17939

2348.1

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 Plane cement concreate grade M 10 Nominal mix 1:3:6 And As Directed by Engineer Incharge

43.56

288502

6623.1

... More
Providing concrete for plain/reinforced concrete in sub structure complete as per drawings and technical specifications Ministry Of Rural Development 2014 Clause 802, 803, 804, 805, 806, 807, 1202 & 1203, 1204 Plain cement concreate grade M 15 Nominal mix (1:2.5:5) And As Directed by Engineer Incharge

301.11

2072856

6884.05

... More
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. B. 1000 milimeter Non pressure 3 Class As per Technical Specification Ministry Of Rural Development 2014 Cluase No. 1100 And As Directed by Engineer Incharge

52.5

416180

7927.25

... More
Providing and laying reinforced cement concrete pipe Non pressure2 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. D. 600 milimeter Non pressure 2 Class As per Technical Specification Ministry Of Rural Development 2014 Cluase No. 1100 And As Directed by Engineer Incharge

312.5

896765

2869.65

... More
Providing weepholes in brick masonry / stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 milimeter dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7 A.C. pipe 100 milimeter Dia And As Directed by Engineer Incharge

20

6372

318.6

... More
Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1303 And As Directed by Engineer Incharge

104.82

237191

2262.85

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per Indian Road Congress:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Ministry Of Rural Development 2014 Clause 1703 Ordinary Kilometer Stone (Precast) And As Directed by Engineer Incharge

5

15613

3122.6

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per Indian Road Congress:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Ministry Of Rural Development 2014 Clause 1703 200 meter stone (precast) And As Directed by Engineer Incharge

16

14012

875.75

... More
Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per Indian Road Congress:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704. And As Directed by Engineer Incharge

388

342371

882.4

... More
MMGSY / PMGSY Citizen' s information Board- Providing and fixing of typical PMGSY Retro Reflective information board as per as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circular and drawing. Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottom duly rivetted with MS angles of 35 x 35 x 5 mm thick M.S angle shall be welded by two vertical M.S angle of 5 mm thick to 75 mm x 75 mm of 12 SWG square tubes / 75mm Dia Pipe posts duly embedded in cement concrete M-20 grade blocks of 600mm x 600mm x 75mm, below ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circular no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4 and as directed by Engineer-In-charge. . A warranty for 5 / 7 years for the Retro reflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor. And As Directed by Engineer Incharge

2

60238

30119.25

... More
Providing and fixing of typical Mukhya Mantri Gram Sadak Yojana informatory sign board with Logo as per Ministry Of Rural Development specifications and drawing. Three Mild steel Plates of 1.6 mm thick, top and middle plate duly welded with Mild steel flat iron 25Millimeter x 5meter size on back on edges. The lower plate will be welded with Mild steel angle iron frame of 25 Millimeter x 25 Millimeter x 5 Millimeter. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75Millimeter x 75 Millimeter of 12 Steel wire Gause sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450Millimeter x 450Millimeter x 600Millimeter, 600Millimeter below ground level. The top most diamond plate will be welded to middle plate by 47Millimeter x 47Millimeter of 12 Steel wire Gauge steel plate tube. All Mild steel will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 'Logo' of Mukhya Mantri Gram Sadak Yojana Project And As Directed by Engineer Incharge

2

38532

19266.15

... More
Providing and erecting direction and place identification of semi reflective sign boards as per IRC-67 made of 2 mm thick M.S. Sheet duly stove enameled paint white colour in front and grey colour on back with reflective border of 70 mm width and required message, letters, figures with reflective tape of engineering grade as per MORD specifications of required shade and colour. Supported and welded on two nos. 47 mm x 47 mm of 12 SWG square tube of 3050 mm height duly strengthened by 25 mm x 5 mm MS flat iron on edges on back firmly fixed to the ground by means of properly designed foundations with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701 And As Directed by Engineer Incharge

6

25889

4314.95

... More
Providing and fixing Cautionary/Warning sign boards in Equilateral Triangle size of mm made out of mm aluminum sheet bonded with white retro reflective sheeting of Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3 Supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with grey stove enamel paint and supported on one no. of M. S. angle iron post of size 65 mm X 65 mm X 6 mm, 3.45 m long, duly painted with with flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in M25 grade concrete block of size 60cm X 60cm X 75cm including transportation etc; complete. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier. And As Directed by Engineer Incharge

35

140715

4020.45

... More
Providing and fixing of retro- reflectorised informatory sign board rectangular/Square in shape having area less than 0.9 One Square Meterr made out of mm aluminum sheet bonded with white retro reflective sheeting of Class ( Type IV High intensity micro- prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3, supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with two coats of grey stove enamel paint and supported on one no. mild steel angle iron post 75 mm x 75 mm x 6 mm, 3.5 mt long firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing The angle iron post shall be duly painted with one coat of epoxy primer and two coats of epoxy finish paints having alternate black and white bands of 25 cm width including GI fixures and transportation etc.complete.The nut bolts of board with angle iron post/supporting structure after fixing at site has to be electrically welded. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) sheeting shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier. 600 x 450 milimeter Rectangular And As Directed by Engineer Incharge

2.16

21924

10150.35

... More
Providing and fixing Mandatory/Regulatory sign boards in circular shape of mm dia made out of mm aluminum sheet bonded with white retro reflective sheeting of Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3 Supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with grey stove enamel paint and supported on one no. of M. S. angle iron post of size 65 mm X 65 mm X 6 mm, 3.45 m long, duly painted with with flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in M25 grade concrete block of size 60cm X 60cm X 75cm including transportation etc; complete. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier. 600mm circular And As Directed by Engineer Incharge

34

161221

4741.8

... More
Providing and Laying hot applied thermoplastic road marking strip on Bituminous Surface of specified shade/ colour of 2.5 mm thick including 1.5 Refractive index reflectorizing glass beads @ 250gm/sqm .Thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC 35:2015. Initial Dry reflectivity RL shall be 250 mcd/sqm/lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/sqm/ lux and Qd of 100 mcd/sqm/ lux measured at the end of 2 years by means of a Standard Reflectometer of Zehntner, Easylux, Delta make capable of measuring RL & QD both according to IRC 35:2015 clause 15.5. The finished surface to be level, uniform, and free from streaks and holes complete as per direction of Engineer-in-charge and in accordance with applicable specifications.(Refer MORTH Clause 803 for technical Specification and Performance for IRC 35:2015) And As Directed by Engineer Incharge

829

579719

699.3

... More
Road Delineators: Supplying and installation of delineators (Roadway Indicators, Hazard markers, Object markers) 80 to 100 cm high above ground level, painted black and white in 15cm wide strips, fitted with 80x100mm rectangular or 75mm dia. Circular reflectorised panels at the top, buried or pressed into the ground and confirming to I.R.C. 79 and the drawings And As Directed by Engineer Incharge

50

43155

863.1

... More
Providing and fixing in position Pipe Railing consisting of IS Rolled steel joist posts designation IS MB 100 (100x75) at 2.5 m interval and three rows of 50 mm dia steel pipes (light) including fixing in position on bridge deck complete as per drawing and technical specifications Clause 1208.2 And As Directed by Engineer Incharge

100

219440

2194.4

... More
Painting two coats including prime coat with epoxy paint of approved brand on concrete/steel surfaces after through cleaning of surface to give an even shade as per drawing and Technical Specification Clause 1701 And As Directed by Engineer Incharge

1.92

333

173.75

... More
White washing two coats on parapet walls and white washing and geru lime painting to tree trunks including preparation of surface by cleaning scraping etc. complete And As Directed by Engineer Incharge

9.6

262

27.3

... More
A,W : Metal Beam Crash Barrier (Providing and erecting a "W "metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip cess, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810) And As Directed by Engineer Incharge

215

1108884

5157.6

... More
Providing and Laying of 2 or more sets (6Nos. each set) Dual Ribs Pattern Rumble Markings on roads with vehicular speeds of more than 50 Km/hr laid as per the spacing recommended for each set under Table11.1 and Fig.11.2 of IRC35:2015 using Plastirib 2K, or equivalent 2 component cold plastic profiled material. Each Dual Rib pattern rumble marking shall have width of 500mm. Each dual rib pattern rumble marking shall have 2 ribs each of Width of 100mm and height 20mm. Gap between two ribs shall be 300mm. Each rumble marking shall be made complete with drop on Soild Plus reflective glass beads @ 300 gm / One Square Metre spread throughout the surface of marking. The finished surface to be levelled,uniform and free from streaks and holes,including surface cleaning and cost of all materials etc. complete. And As Directed by Engineer Incharge

9

40946

4549.65

... More
F) Improvement of Road from SH 143 Vibhutwadi to Gulewadi Ch 0/000 to 3/630, Taluka -Atpadi, District:-Sangli, Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 milimeter, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 meter including removal and disposal of top organic soil not exceeding 150 milimeter in thickness as per Technical Specification Ministry Of Rural Development 2014 Clause 201. By mechnical means (A) In area Non of thorny jungle And As Directed by Engineer Incharge

1.09

28918

26530.8

... More
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 milimeter, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 meter including removal and disposal of top organic soil not exceeding 150 milimeter in thickness as per Technical Specification Ministry Of Rural Development 2014 Clause 201.By mechnical means (B) In area of thorny jungle And As Directed by Engineer Incharge

0.73

24074

32978.7

... More
Excavation for roadwork in soil with hydraulic excavator of 0.9 cubicmeter bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with a lift upto 1.5 meter and lead more than 100 meter as per Technical Specification Ministry Of Rural Development 2014 Clause 302.3 And As Directed by Engineer Incharge

5630.97

416410

73.95

... More
Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cubicmeter bucket capacity including cutting and loading in tippers, transporting to embankment site with a lift upto 1.5 meter and lead above 100 meter, trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections as per Technical Specification Ministry Of Rural Development 2014 Clause 302.3.5 And As Directed by Engineer Incharge

1387.22

150790

108.7

... More
Excavation for roadway in hard rock (requiring blasting) by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross-sections, loading and disposal of cut rock with a lift upto 1.5 meter and leads upto 1000 meter as per Technical Specification Clause 302.3.5 And As Directed by Engineer Incharge

189.47

28524

150.55

... More
Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal with a lift upto 1.5 meter and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification Clause 302.3.5 And As Directed by Engineer Incharge

81.21

42736

526.25

... More
Scarifying existing bituminous surface to a depth of 150 mm and disposal of scarified material with a lift upto 3 m and leads upto 1000 m as per Technical Specification Clause 301.4. as per Technical Specification Clause 301.4 And As Directed by Engineer Incharge

11002.5

173839

15.8

... More
Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Ministry Of Rural Development 2014 Clause 301.5 And As Directed by Engineer Incharge

1760.25

147596

83.85

... More
Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 And As Directed by Engineer Incharge

474.39

254699

536.9

... More
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 as per Technical Specification Ministry Of Rural Development 2014 Clause 303.1. And As Directed by Engineer Incharge

3015.08

1922115

637.5

... More
Setting Out And As Directed by Engineer Incharge

3.63

93770

25832.17

... More
Construction of Granular sub-base grade -II by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator and compacting with vibretary wheel roller to achieve the desired density, complete as per Technical Specification Ministry Of Rural Development 2014 Clause 401. And As Directed by Engineer Incharge

488.48

976447

1998.95

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kilonewton static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Water bound macadum Grading 2 as per Technical Specification Ministry Of Rural Development 2014 Clause 405. For - By Mechanical Means And As Directed by Engineer Incharge

173.68

374766

2157.8

... More
Providing and laying White Topping/Short Paneled Concrete as per IRC-SP 76-2015 (Existing surface preparation to be done if necessary either by milling or leveling course with DLC to correct surface profile and to be paid separately) with un reinforced M-40 grade Pavement Quality Concrete using Ordinary Portland Cement 43/53 Grade OR Portland Pozzolona Cement IS-1489 at 425kg/cum, coarse aggregate, fine aggregate(VSI) and Admixture confirming to IS 9130-1999 (R-2004) polymeric synthetic fiber as per ASTM (1116) such as polyester / polyethylene / polypropylene / Glass fiber at 1.20 kg/cum, mixed in batching and mixing plant or weigh batcher as per approved mix design to achieve minimum flexural strength or modulus of rupture of concrete 4.50 MPa at 28 days limiting maximum water cement ratio to 0.40, transported to site, laid with fixed form/ slip form paver finisher (preferably with slip form paver finisher), spread, vibrated, compacted and finished in a continuous operation to the lines and grades as per drawing, texture finishing of surface, spraying two layers of curing compound, curing with water sprayed on hessian cloth covered over concrete surface, groove cutting grid 1m x 1m or as directed by Engineer Incharge to a depth of 1/3 to 1/4 of the Thickness and of width 3-5 mm as per design including cost of all material, side form work, labour and machineries etc. complete as per specifications.(Excluding Dowel Bars and Tie Bars) ( Including Polythene sheet 125 micron) And As Directed by Engineer Incharge

2203.98

16359702

7422.8

... More
Providing & Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate ( natural sand/ VSI grade finely washed crushed sand) conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, , cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days,mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts,laid with a paver with electronic sensor /by suitable means as approved by Engineer-in charge , compacting with vibratory roller, finishing, curing and including preparation of sub-grade surface if required etc. complete. And As Directed by Engineer Incharge

1584.9

5396426

3404.9

... More
Providing and fixing in position 25mm dia anti corrosive MS dowel bars of required Dia. 60 cms. Long and at 30.00 cm. C/C and wherever directed including handling. straightening, necessary cutting supported by chairs with proper alignment with half length covered by polyethene sheathing including cap etc. complete.And As Directed by Engineer Incharge

432

100375

232.35

... More
Providing and fixing in position anticorrosive TMT FE 500 tie bars of 12 mm dia. 70 cms. long and at 30.00 cm. C/C and wherever directed including handling, straightening necessary cutting, handling, straightening, supported by assembly of TMT FE 500, chairs with proper alignment etc. complete.And As Directed by Engineer Incharge

12208

775208

63.5

... More
Earthwork in excavation for structures as per drawing and technical specifications Ministry Of Rural Development 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 meter, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary soil And As Directed by Engineer Incharge

286.1

191758

670.25

... More
Earthwork in excavation for structures as per drawing and technical specifications Ministry Of Rural Development 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 meter, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary rock (not requiring blasting) Upto 3 meter depth And As Directed by Engineer Incharge

148.97

124814

837.85

... More
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Hard rock (blasting prohibited) Upto 3 meter depth And As Directed by Engineer Incharge

52.45

61783

1177.95

... More
Filling in foundation trenches as per drawing and technical specification Clause 305.3.9 Rubble soling with Rubble And As Directed by Engineer Incharge

7.3

16520

2263.05

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 Plane cement concreate grade M 10 Nominal mix 1:3:6 And As Directed by Engineer Incharge

45.79

281200

6141.1

... More
Providing concrete for plain/reinforced concrete in sub structure complete as per drawings and technical specifications Ministry Of Rural Development 2014 Clause 802, 803, 804, 805, 806, 807, 1202 & 1203, 1204 Plain cement concreate grade M 15 Nominal mix (1:2.5:5) And As Directed by Engineer Incharge

466.61

2990970

6410

... More
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. B. 1000 milimeter Non pressure 3 Class As per Technical Specification Ministry Of Rural Development 2014 Cluase No. 1100 And As Directed by Engineer Incharge

60

452985

7549.75

... More
Providing and laying reinforced cement concrete pipe Non pressure2 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. D. 600 milimeter Non pressure 2 Class As per Technical Specification Ministry Of Rural Development 2014 Cluase No. 1100 And As Directed by Engineer Incharge

252.5

690082

2733

... More
Providing weepholes in brick masonry / stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 milimeter dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7 A.C. pipe 100 milimeter Dia And As Directed by Engineer Incharge

50

15170

303.4

... More
Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1303 And As Directed by Engineer Incharge

125.26

251396

2007

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per Indian Road Congress:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Ministry Of Rural Development 2014 Clause 1703 Ordinary Kilometer Stone (Precast) And As Directed by Engineer Incharge

4

11895

2973.9

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per Indian Road Congress:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Ministry Of Rural Development 2014 Clause 1703 200 meter stone (precast) And As Directed by Engineer Incharge

15

12510

834.05

... More
Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per Indian Road Congress:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704. And As Directed by Engineer Incharge

346

290778

840.4

... More
MMGSY / PMGSY Citizen' s information Board- Providing and fixing of typical PMGSY Retro Reflective information board as per as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circular and drawing. Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottom duly rivetted with MS angles of 35 x 35 x 5 mm thick M.S angle shall be welded by two vertical M.S angle of 5 mm thick to 75 mm x 75 mm of 12 SWG square tubes / 75mm Dia Pipe posts duly embedded in cement concrete M-20 grade blocks of 600mm x 600mm x 75mm, below ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circular no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4 and as directed by Engineer-In-charge. . A warranty for 5 / 7 years for the Retro reflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor And As Directed by Engineer Incharge.

2

57370

28685

... More
Providing and fixing of typical Mukhya Mantri Gram Sadak Yojana informatory sign board with Logo as per Ministry Of Rural Development specifications and drawing. Three Mild steel Plates of 1.6 mm thick, top and middle plate duly welded with Mild steel flat iron 25Millimeter x 5meter size on back on edges. The lower plate will be welded with Mild steel angle iron frame of 25 Millimeter x 25 Millimeter x 5 Millimeter. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75Millimeter x 75 Millimeter of 12 Steel wire Gause sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450Millimeter x 450Millimeter x 600Millimeter, 600Millimeter below ground level. The top most diamond plate will be welded to middle plate by 47Millimeter x 47Millimeter of 12 Steel wire Gauge steel plate tube. All Mild steel will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 'Logo' of Mukhya Mantri Gram Sadak Yojana Project And As Directed by Engineer Incharge

2

36697

18348.7

... More
Providing and erecting direction and place identification of semi reflective sign boards as per IRC-67 made of 2 mm thick M.S. Sheet duly stove enameled paint white colour in front and grey colour on back with reflective border of 70 mm width and required message, letters, figures with reflective tape of engineering grade as per MORD specifications of required shade and colour. Supported and welded on two nos. 47 mm x 47 mm of 12 SWG square tube of 3050 mm height duly strengthened by 25 mm x 5 mm MS flat iron on edges on back firmly fixed to the ground by means of properly designed foundations with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701

8

32876

4109.5

... More
Providing and fixing Cautionary/Warning sign boards in Equilateral Triangle size of mm made out of mm aluminum sheet bonded with white retro reflective sheeting of Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3 Supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with grey stove enamel paint and supported on one no. of M. S. angle iron post of size 65 mm X 65 mm X 6 mm, 3.45 m long, duly painted with with flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in M25 grade concrete block of size 60cm X 60cm X 75cm including transportation etc; complete. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier. And As Directed by Engineer Incharge

36

137844

3829

... More
Providing and fixing of retro- reflectorised informatory sign board rectangular/Square in shape having area less than 0.9 One Square Meterr made out of mm aluminum sheet bonded with white retro reflective sheeting of Class ( Type IV High intensity micro- prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3, supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with two coats of grey stove enamel paint and supported on one no. mild steel angle iron post 75 mm x 75 mm x 6 mm, 3.5 mt long firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing The angle iron post shall be duly painted with one coat of epoxy primer and two coats of epoxy finish paints having alternate black and white bands of 25 cm width including GI fixures and transportation etc.complete.The nut bolts of board with angle iron post/supporting structure after fixing at site has to be electrically welded. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) sheeting shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier. 600 x 450 milimeter Rectangular And As Directed by Engineer Incharge

2.16

20880

9667

... More
Providing and fixing Mandatory/Regulatory sign boards in circular shape of mm dia made out of mm aluminum sheet bonded with white retro reflective sheeting of Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3 Supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with grey stove enamel paint and supported on one no. of M. S. angle iron post of size 65 mm X 65 mm X 6 mm, 3.45 m long, duly painted with with flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in M25 grade concrete block of size 60cm X 60cm X 75cm including transportation etc; complete. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier. 600mm circular And As Directed by Engineer Incharge

40

180640

4516

... More
Providing and Laying hot applied thermoplastic road marking strip on Bituminous Surface of specified shade/ colour of 2.5 mm thick including 1.5 Refractive index reflectorizing glass beads @ 250gm/sqm .Thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC 35:2015. Initial Dry reflectivity RL shall be 250 mcd/sqm/lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/sqm/ lux and Qd of 100 mcd/sqm/ lux measured at the end of 2 years by means of a Standard Reflectometer of Zehntner, Easylux, Delta make capable of measuring RL & QD both according to IRC 35:2015 clause 15.5. The finished surface to be level, uniform, and free from streaks and holes complete as per direction of Engineer-in-charge and in accordance with applicable specifications.(Refer MORTH Clause 803 for technical Specification and Performance for IRC 35:2015) And As Directed by Engineer Incharge

736.5

490509

666

... More
Road Delineators: Supplying and installation of delineators (Roadway Indicators, Hazard markers, Object markers) 80 to 100 cm high above ground level, painted black and white in 15cm wide strips, fitted with 80x100mm rectangular or 75mm dia. Circular reflectorised panels at the top, buried or pressed into the ground and confirming to I.R.C. 79 and the drawings And As Directed by Engineer Incharge

40

32880

822

... More
Providing and fixing in position Pipe Railing consisting of IS Rolled steel joist posts designation IS MB 100 (100x75) at 2.5 m interval and three rows of 50 mm dia steel pipes (light) including fixing in position on bridge deck complete as per drawing and technical specifications Clause 1208.2 And As Directed by Engineer Incharge

50

104495

2089.9

... More
Painting two coats including prime coat with epoxy paint of approved brand on concrete/steel surfaces after through cleaning of surface to give an even shade as per drawing and Technical Specification Clause 1701 And As Directed by Engineer Incharge

1.44

238

165.45

... More
White washing two coats on parapet walls and white washing and geru lime painting to tree trunks including preparation of surface by cleaning scraping etc. complete And As Directed by Engineer Incharge

20

520

26

... More
A,W : Metal Beam Crash Barrier (Providing and erecting a "W "metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip cess, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810) And As Directed by Engineer Incharge

270

1326240

4912

... More
Providing and Laying of 2 or more sets (6Nos. each set) Dual Ribs Pattern Rumble Markings on roads with vehicular speeds of more than 50 Km/hr laid as per the spacing recommended for each set under Table11.1 and Fig.11.2 of IRC35:2015 using Plastirib 2K, or equivalent 2 component cold plastic profiled material. Each Dual Rib pattern rumble marking shall have width of 500mm. Each dual rib pattern rumble marking shall have 2 ribs each of Width of 100mm and height 20mm. Gap between two ribs shall be 300mm. Each rumble marking shall be made complete with drop on Soild Plus reflective glass beads @ 300 gm / One Square Metre spread throughout the surface of marking. The finished surface to be levelled,uniform and free from streaks and holes,including surface cleaning and cost of all materials etc. complete. And As Directed by Engineer Incharge.

10.5

45496

4333

... More
G) Improvement of Road from Hivare to Jadhvwasti Ch 0/000 to 2/370, Taluka -Khanapur, District:-Sangli, Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 milimeter, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 meter including removal and disposal of top organic soil not exceeding 150 milimeter in thickness as per Technical Specification Ministry Of Rural Development 2014 Clause 201. By mechnical means (A) In area Non of thorny jungle And As Directed by Engineer Incharge

0.72

19102

26530.9

... More
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 milimeter, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 meter including removal and disposal of top organic soil not exceeding 150 milimeter in thickness as per Technical Specification Ministry Of Rural Development 2014 Clause 201.By mechnical means (B) In area of thorny jungle And As Directed by Engineer Incharge

0.48

15829

32978.7

... More
Excavation for roadwork in soil with hydraulic excavator of 0.9 cubicmeter bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with a lift upto 1.5 meter and lead more than 100 meter as per Technical Specification Ministry Of Rural Development 2014 Clause 302.3 And As Directed by Engineer Incharge

4376.75

323660

73.95

... More
Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cubicmeter bucket capacity including cutting and loading in tippers, transporting to embankment site with a lift upto 1.5 meter and lead above 100 meter, trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections as per Technical Specification Ministry Of Rural Development 2014 Clause 302.3.5 And As Directed by Engineer Incharge

1546.25

168077

108.7

... More
Excavation for roadway in hard rock (requiring blasting) by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross-sections, loading and disposal of cut rock with a lift upto 1.5 meter and leads upto 1000 meter as per Technical Specification Clause 302.3.5 And As Directed by Engineer Incharge

276.29

41595

150.55

... More
Scarifying existing bituminous surface to a depth of 150 mm and disposal of scarified material with a lift upto 3 m and leads upto 1000 m as per Technical Specification Clause 301.4. as per Technical Specification Clause 301.4 And As Directed by Engineer Incharge

2460

38868

15.8

... More
Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Ministry Of Rural Development 2014 Clause 301.5 And As Directed by Engineer Incharge

2738.18

229596

83.85

... More
Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 And As Directed by Engineer Incharge

1967.54

1185442

602.5

... More
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 as per Technical Specification Ministry Of Rural Development 2014 Clause 303.1. And As Directed by Engineer Incharge

1961.53

1384742

705.95

... More
Loosening, Levelling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 milimeter, mixed with water at optimum moisture content and then compacted by rolling so as to achieve minimum dry density as given in Tables 300.1 and 300.2 for embankment construction as per Technical Specification Clause 301.4.1.And As Directed by Engineer Incharge And As Directed by Engineer Incharge

1860

61194

32.9

... More
Setting Out And As Directed by Engineer Incharge

2.37

61753

26056.13

... More
Construction of Granular sub-base grade -II by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator and compacting with vibretary wheel roller to achieve the desired density, complete as per Technical Specification Ministry Of Rural Development 2014 Clause 401. And As Directed by Engineer Incharge

778.2

1826124

2346.6

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kilonewton static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Water bound macadum Grading 2 as per Technical Specification Ministry Of Rural Development 2014 Clause 405. For - By Mechanical Means And As Directed by Engineer Incharge

88.34

221556

2508

... More
Providing and laying White Topping/Short Paneled Concrete as per IRC-SP 76-2015 (Existing surface preparation to be done if necessary either by milling or leveling course with DLC to correct surface profile and to be paid separately) with un reinforced M-40 grade Pavement Quality Concrete using Ordinary Portland Cement 43/53 Grade OR Portland Pozzolona Cement IS-1489 at 425kg/cum, coarse aggregate, fine aggregate(VSI) and Admixture confirming to IS 9130-1999 (R-2004) polymeric synthetic fiber as per ASTM (1116) such as polyester / polyethylene / polypropylene / Glass fiber at 1.20 kg/cum, mixed in batching and mixing plant or weigh batcher as per approved mix design to achieve minimum flexural strength or modulus of rupture of concrete 4.50 MPa at 28 days limiting maximum water cement ratio to 0.40, transported to site, laid with fixed form/ slip form paver finisher (preferably with slip form paver finisher), spread, vibrated, compacted and finished in a continuous operation to the lines and grades as per drawing, texture finishing of surface, spraying two layers of curing compound, curing with water sprayed on hessian cloth covered over concrete surface, groove cutting grid 1m x 1m or as directed by Engineer Incharge to a depth of 1/3 to 1/4 of the Thickness and of width 3-5 mm as per design including cost of all material, side form work, labour and machineries etc. complete as per specifications.(Excluding Dowel Bars and Tie Bars) ( Including Polythene sheet 125 micron) And As Directed by Engineer Incharge

1412.95

10976219

7768.3

... More
Providing & Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate ( natural sand/ VSI grade finely washed crushed sand) conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, , cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days,mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts,laid with a paver with electronic sensor /by suitable means as approved by Engineer-in charge , compacting with vibratory roller, finishing, curing and including preparation of sub-grade surface if required etc. complete. And As Directed by Engineer Incharge

1016.1

3823279

3762.7

... More
Providing and fixing in position 25mm dia anti corrosive MS dowel bars of required Dia. 60 cms. Long and at 30.00 cm. C/C and wherever directed including handling. straightening, necessary cutting supported by chairs with proper alignment with half length covered by polyethene sheathing including cap etc. complete.And As Directed by Engineer Incharge

312

72493

232.35

... More
Providing and fixing in position anticorrosive TMT FE 500 tie bars of 12 mm dia. 70 cms. long and at 30.00 cm. C/C and wherever directed including handling, straightening necessary cutting, handling, straightening, supported by assembly of TMT FE 500, chairs with proper alignment etc. complete.And As Directed by Engineer Incharge

7920

502920

63.5

... More
Earthwork in excavation for structures as per drawing and technical specifications Ministry Of Rural Development 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 meter, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary soil And As Directed by Engineer Incharge

210.74

141248

670.25

... More
Earthwork in excavation for structures as per drawing and technical specifications Ministry Of Rural Development 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 meter, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary rock (not requiring blasting) Upto 3 meter depth And As Directed by Engineer Incharge

123.44

103424

837.85

... More
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Hard rock (blasting prohibited) Upto 3 meter depth And As Directed by Engineer Incharge

55.21

53117

962.1

... More
Filling in foundation trenches as per drawing and technical specification Clause 305.3.9 Rubble soling with Rubble And As Directed by Engineer Incharge

29.18

66035

2263.05

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 Plane cement concreate grade M 10 Nominal mix 1:3:6 And As Directed by Engineer Incharge

30.89

201487

6522.75

... More
Providing concrete for plain/reinforced concrete in sub structure complete as per drawings and technical specifications Ministry Of Rural Development 2014 Clause 802, 803, 804, 805, 806, 807, 1202 & 1203, 1204 Plain cement concreate grade M 15 Nominal mix (1:2.5:5) And As Directed by Engineer Incharge

286.54

1933586

6748.05

... More
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. B. 1000 milimeter Non pressure 3 Class As per Technical Specification Ministry Of Rural Development 2014 Cluase No. 1100 And As Directed by Engineer Incharge

67.5

509608

7549.75

... More
Providing and laying reinforced cement concrete pipe Non pressure2 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. D. 600 milimeter Non pressure 2 Class As per Technical Specification Ministry Of Rural Development 2014 Cluase No. 1100 And As Directed by Engineer Incharge

152.5

416782

2733

... More
Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1303 And As Directed by Engineer Incharge

90.76

211870

2334.4

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per Indian Road Congress:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Ministry Of Rural Development 2014 Clause 1703 Ordinary Kilometer Stone (Precast) And As Directed by Engineer Incharge

3

8921

2973.9

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per Indian Road Congress:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Ministry Of Rural Development 2014 Clause 1703 200 meter stone (precast) And As Directed by Engineer Incharge

10

8340

834.05

... More
Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per Indian Road Congress:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704. And As Directed by Engineer Incharge

230

193292

840.4

... More
MMGSY / PMGSY Citizen' s information Board- Providing and fixing of typical PMGSY Retro Reflective information board as per as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circular and drawing. Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottom duly rivetted with MS angles of 35 x 35 x 5 mm thick M.S angle shall be welded by two vertical M.S angle of 5 mm thick to 75 mm x 75 mm of 12 SWG square tubes / 75mm Dia Pipe posts duly embedded in cement concrete M-20 grade blocks of 600mm x 600mm x 75mm, below ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circular no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4 and as directed by Engineer-In-charge. . A warranty for 5 / 7 years for the Retro reflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor. And As Directed by Engineer Incharge

2

57370

28685

... More
Providing and fixing of typical Mukhya Mantri Gram Sadak Yojana informatory sign board with Logo as per Ministry Of Rural Development specifications and drawing. Three Mild steel Plates of 1.6 mm thick, top and middle plate duly welded with Mild steel flat iron 25Millimeter x 5meter size on back on edges. The lower plate will be welded with Mild steel angle iron frame of 25 Millimeter x 25 Millimeter x 5 Millimeter. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75Millimeter x 75 Millimeter of 12 Steel wire Gause sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450Millimeter x 450Millimeter x 600Millimeter, 600Millimeter below ground level. The top most diamond plate will be welded to middle plate by 47Millimeter x 47Millimeter of 12 Steel wire Gauge steel plate tube. All Mild steel will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 'Logo' of Mukhya Mantri Gram Sadak Yojana Project And As Directed by Engineer Incharge

2

36697

18348.7

... More
Providing and erecting direction and place identification of semi reflective sign boards as per IRC-67 made of 2 mm thick M.S. Sheet duly stove enameled paint white colour in front and grey colour on back with reflective border of 70 mm width and required message, letters, figures with reflective tape of engineering grade as per MORD specifications of required shade and colour. Supported and welded on two nos. 47 mm x 47 mm of 12 SWG square tube of 3050 mm height duly strengthened by 25 mm x 5 mm MS flat iron on edges on back firmly fixed to the ground by means of properly designed foundations with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701 And As Directed by Engineer Incharge

6

24657

4109.5

... More
Providing and fixing Cautionary/Warning sign boards in Equilateral Triangle size of mm made out of mm aluminum sheet bonded with white retro reflective sheeting of Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3 Supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with grey stove enamel paint and supported on one no. of M. S. angle iron post of size 65 mm X 65 mm X 6 mm, 3.45 m long, duly painted with with flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in M25 grade concrete block of size 60cm X 60cm X 75cm including transportation etc; complete. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier. And As Directed by Engineer Incharge

24

91896

3829

... More
Providing and fixing of retro- reflectorised informatory sign board rectangular/Square in shape having area less than 0.9 One Square Meterr made out of mm aluminum sheet bonded with white retro reflective sheeting of Class ( Type IV High intensity micro- prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3, supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with two coats of grey stove enamel paint and supported on one no. mild steel angle iron post 75 mm x 75 mm x 6 mm, 3.5 mt long firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing The angle iron post shall be duly painted with one coat of epoxy primer and two coats of epoxy finish paints having alternate black and white bands of 25 cm width including GI fixures and transportation etc.complete.The nut bolts of board with angle iron post/supporting structure after fixing at site has to be electrically welded. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) sheeting shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier. 600 x 450 milimeter Rectangular And As Directed by Engineer Incharge

1.62

15660

9667

... More
Providing and fixing Mandatory/Regulatory sign boards in circular shape of mm dia made out of mm aluminum sheet bonded with white retro reflective sheeting of Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3 Supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with grey stove enamel paint and supported on one no. of M. S. angle iron post of size 65 mm X 65 mm X 6 mm, 3.45 m long, duly painted with with flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in M25 grade concrete block of size 60cm X 60cm X 75cm including transportation etc; complete. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier. 600mm circular And As Directed by Engineer Incharge

24

108384

4516

... More
Providing and Laying hot applied thermoplastic road marking strip on Bituminous Surface of specified shade/ colour of 2.5 mm thick including 1.5 Refractive index reflectorizing glass beads @ 250gm/sqm .Thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC 35:2015. Initial Dry reflectivity RL shall be 250 mcd/sqm/lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/sqm/ lux and Qd of 100 mcd/sqm/ lux measured at the end of 2 years by means of a Standard Reflectometer of Zehntner, Easylux, Delta make capable of measuring RL & QD both according to IRC 35:2015 clause 15.5. The finished surface to be level, uniform, and free from streaks and holes complete as per direction of Engineer-in-charge and in accordance with applicable specifications.(Refer MORTH Clause 803 for technical Specification and Performance for IRC 35:2015) And As Directed by Engineer Incharge

483

321678

666

... More
Road Delineators: Supplying and installation of delineators (Roadway Indicators, Hazard markers, Object markers) 80 to 100 cm high above ground level, painted black and white in 15cm wide strips, fitted with 80x100mm rectangular or 75mm dia. Circular reflectorised panels at the top, buried or pressed into the ground and confirming to I.R.C. 79 and the drawings And As Directed by Engineer Incharge

32

26304

822

... More
Providing and fixing in position Pipe Railing consisting of IS Rolled steel joist posts designation IS MB 100 (100x75) at 2.5 m interval and three rows of 50 mm dia steel pipes (light) including fixing in position on bridge deck complete as per drawing and technical specifications Clause 1208.2 And As Directed by Engineer Incharge

90

188091

2089.9

... More
Painting two coats including prime coat with epoxy paint of approved brand on concrete/steel surfaces after through cleaning of surface to give an even shade as per drawing and Technical Specification Clause 1701 And As Directed by Engineer Incharge

1.44

238

165.45

... More
White washing two coats on parapet walls and white washing and geru lime painting to tree trunks including preparation of surface by cleaning scraping etc. complete And As Directed by Engineer Incharge

9

234

26

... More
A,W : Metal Beam Crash Barrier (Providing and erecting a "W "metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip cess, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810) And As Directed by Engineer Incharge

140

687680

4912

... More
Providing and Laying of 2 or more sets (6Nos. each set) Dual Ribs Pattern Rumble Markings on roads with vehicular speeds of more than 50 Km/hr laid as per the spacing recommended for each set under Table11.1 and Fig.11.2 of IRC35:2015 using Plastirib 2K, or equivalent 2 component cold plastic profiled material. Each Dual Rib pattern rumble marking shall have width of 500mm. Each dual rib pattern rumble marking shall have 2 ribs each of Width of 100mm and height 20mm. Gap between two ribs shall be 300mm. Each rumble marking shall be made complete with drop on Soild Plus reflective glass beads @ 300 gm / One Square Metre spread throughout the surface of marking. The finished surface to be levelled,uniform and free from streaks and holes,including surface cleaning and cost of all materials etc. complete. And As Directed by Engineer Incharge.

9

38997

4333

... More
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete And As Directed by Engineer Incharge.

45.5

29936

657.95

... More
Providing groove to required size at specified location as directed by Engineer, at junction of brick masonry wall and R.C.C beams or Column, at junction of composite masonry, including scaffolding, finishing, curing etc. Complete And As Directed by Engineer Incharge

13.65

642

47.1

... More
Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete And As Directed by Engineer Incharge

12.6

718

57

... More
H) Improvement of Road from Kamlapur to Mahalaxmi Mandir Ch 0/000 to 4/000, Taluka -Khanapur, District:-Sangli, Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 milimeter, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 meter including removal and disposal of top organic soil not exceeding 150 milimeter in thickness as per Technical Specification Ministry Of Rural Development 2014 Clause 201. By mechnical means (A) In area Non of thorny jungle And As Directed by Engineer Incharge

1.2

33428

27857.45

... More
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 milimeter, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 meter including removal and disposal of top organic soil not exceeding 150 milimeter in thickness as per Technical Specification Ministry Of Rural Development 2014 Clause 201.By mechnical means (B) In area of thorny jungle And As Directed by Engineer Incharge

0.8

27702

34627.65

... More
Excavation for roadwork in soil with hydraulic excavator of 0.9 cubicmeter bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with a lift upto 1.5 meter and lead more than 100 meter as per Technical Specification Ministry Of Rural Development 2014 Clause 302.3 And As Directed by Engineer Incharge

4203.18

249668

59.4

... More
Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cubicmeter bucket capacity including cutting and loading in tippers, transporting to embankment site with a lift upto 1.5 meter and lead above 100 meter, trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections as per Technical Specification Ministry Of Rural Development 2014 Clause 302.3.5 And As Directed by Engineer Incharge

1742.4

198807

114.1

... More
Excavation for roadway in hard rock (requiring blasting) by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross-sections, loading and disposal of cut rock with a lift upto 1.5 meter and leads upto 1000 meter as per Technical Specification Clause 302.3.5 And As Directed by Engineer Incharge

41.28

6524

158.05

... More
Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal with a lift upto 1.5 meter and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification Clause 302.3.5 And As Directed by Engineer Incharge

17.69

9774

552.55

... More
Scarifying existing bituminous surface to a depth of 150 mm and disposal of scarified material with a lift upto 3 m and leads upto 1000 m as per Technical Specification Clause 301.4. as per Technical Specification Clause 301.4 And As Directed by Engineer Incharge

1387.5

23032

16.6

... More
Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Ministry Of Rural Development 2014 Clause 301.5 And As Directed by Engineer Incharge

3336.55

293783

88.05

... More
Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 And As Directed by Engineer Incharge

5707.1

3572929

626.05

... More
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 as per Technical Specification Ministry Of Rural Development 2014 Clause 303.1. And As Directed by Engineer Incharge

3815.21

2801890

734.4

... More
Loosening, Levelling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 milimeter, mixed with water at optimum moisture content and then compacted by rolling so as to achieve minimum dry density as given in Tables 300.1 and 300.2 for embankment construction as per Technical Specification Clause 301.4.1.And As Directed by Engineer Incharge And As Directed by Engineer Incharge

4628.25

159906

34.55

... More
Setting Out And As Directed by Engineer Incharge

4

104998

26249.75

... More
Construction of Granular sub-base grade -II by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator and compacting with vibretary wheel roller to achieve the desired density, complete as per Technical Specification Ministry Of Rural Development 2014 Clause 401. And As Directed by Engineer Incharge

1947.88

4563298

2342.7

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kilonewton static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Water bound macadum Grading 2 as per Technical Specification Ministry Of Rural Development 2014 Clause 405. For - By Mechanical Means And As Directed by Engineer Incharge

10.72

26966

2515.5

... More
Providing and laying White Topping/Short Paneled Concrete as per IRC-SP 76-2015 (Existing surface preparation to be done if necessary either by milling or leveling course with DLC to correct surface profile and to be paid separately) with un reinforced M-40 grade Pavement Quality Concrete using Ordinary Portland Cement 43/53 Grade OR Portland Pozzolona Cement IS-1489 at 425kg/cum, coarse aggregate, fine aggregate(VSI) and Admixture confirming to IS 9130-1999 (R-2004) polymeric synthetic fiber as per ASTM (1116) such as polyester / polyethylene / polypropylene / Glass fiber at 1.20 kg/cum, mixed in batching and mixing plant or weigh batcher as per approved mix design to achieve minimum flexural strength or modulus of rupture of concrete 4.50 MPa at 28 days limiting maximum water cement ratio to 0.40, transported to site, laid with fixed form/ slip form paver finisher (preferably with slip form paver finisher), spread, vibrated, compacted and finished in a continuous operation to the lines and grades as per drawing, texture finishing of surface, spraying two layers of curing compound, curing with water sprayed on hessian cloth covered over concrete surface, groove cutting grid 1m x 1m or as directed by Engineer Incharge to a depth of 1/3 to 1/4 of the Thickness and of width 3-5 mm as per design including cost of all material, side form work, labour and machineries etc. complete as per specifications.(Excluding Dowel Bars and Tie Bars) ( Including Polythene sheet 125 micron) And As Directed by Engineer Incharge

2379.25

19115727

8034.35

... More
Providing & Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate ( natural sand/ VSI grade finely washed crushed sand) conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, , cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days,mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts,laid with a paver with electronic sensor /by suitable means as approved by Engineer-in charge , compacting with vibratory roller, finishing, curing and including preparation of sub-grade surface if required etc. complete. And As Directed by Engineer Incharge

1711.26

6544286

3824.25

... More
Providing and fixing in position 25mm dia anti corrosive MS dowel bars of required Dia. 60 cms. Long and at 30.00 cm. C/C and wherever directed including handling. straightening, necessary cutting supported by chairs with proper alignment with half length covered by polyethene sheathing including cap etc. complete.And As Directed by Engineer Incharge

520

126828

243.9

... More
Providing and fixing in position anticorrosive TMT FE 500 tie bars of 12 mm dia. 70 cms. long and at 30.00 cm. C/C and wherever directed including handling, straightening necessary cutting, handling, straightening, supported by assembly of TMT FE 500, chairs with proper alignment etc. complete.And As Directed by Engineer Incharge

13516

900841

66.65

... More
Removing all types of Hume pipes and stacking within a lead of 1000 m including Earthwork and Dismantling of Masonry Works as per Technical Specification MORD 2014 Clause 202. Upto 600 mm dia Hume pipe And As Directed by Engineer Incharge

15

9262

617.5

... More
Earthwork in excavation for structures as per drawing and technical specifications Ministry Of Rural Development 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 meter, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary soil And As Directed by Engineer Incharge

388.06

273097

703.75

... More
Earthwork in excavation for structures as per drawing and technical specifications Ministry Of Rural Development 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 meter, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary rock (not requiring blasting) Upto 3 meter depth And As Directed by Engineer Incharge

191.31

168295

879.7

... More
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Hard rock (blasting prohibited) Upto 3 meter depth And As Directed by Engineer Incharge

39.34

39741

1010.2

... More
Filling in foundation trenches as per drawing and technical specification Clause 305.3.9 Rubble soling with Rubble And As Directed by Engineer Incharge

51.02

119800

2348.1

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 Plane cement concreate grade M 10 Nominal mix 1:3:6 And As Directed by Engineer Incharge

54.81

367912

6712.5

... More
Providing concrete for plain/reinforced concrete in sub structure complete as per drawings and technical specifications Ministry Of Rural Development 2014 Clause 802, 803, 804, 805, 806, 807, 1202 & 1203, 1204 Plain cement concreate grade M 15 Nominal mix (1:2.5:5) And As Directed by Engineer Incharge

414.41

2885889

6963.85

... More
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. B. 1000 milimeter Non pressure 3 Class As per Technical Specification Ministry Of Rural Development 2014 Cluase No. 1100 And As Directed by Engineer Incharge

97.5

772906

7927.25

... More
Providing and laying reinforced cement concrete pipe Non pressure2 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. D. 600 milimeter Non pressure 2 Class As per Technical Specification Ministry Of Rural Development 2014 Cluase No. 1100 And As Directed by Engineer Incharge

230

660019

2869.65

... More
Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1303 And As Directed by Engineer Incharge

145.61

340283

2336.95

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per Indian Road Congress:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Ministry Of Rural Development 2014 Clause 1703 Ordinary Kilometer Stone (Precast) And As Directed by Engineer Incharge

5

15613

3122.6

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per Indian Road Congress:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Ministry Of Rural Development 2014 Clause 1703 200 meter stone (precast) And As Directed by Engineer Incharge

16

14012

875.75

... More
Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per Indian Road Congress:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704. And As Directed by Engineer Incharge

280

247072

882.4

... More
MMGSY / PMGSY Citizen' s information Board- Providing and fixing of typical PMGSY Retro Reflective information board as per as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circular and drawing. Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottom duly rivetted with MS angles of 35 x 35 x 5 mm thick M.S angle shall be welded by two vertical M.S angle of 5 mm thick to 75 mm x 75 mm of 12 SWG square tubes / 75mm Dia Pipe posts duly embedded in cement concrete M-20 grade blocks of 600mm x 600mm x 75mm, below ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circular no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4 and as directed by Engineer-In-charge. . A warranty for 5 / 7 years for the Retro reflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor.

2

60238

30119.25

... More
Providing and fixing of typical Mukhya Mantri Gram Sadak Yojana informatory sign board with Logo as per Ministry Of Rural Development specifications and drawing. Three Mild steel Plates of 1.6 mm thick, top and middle plate duly welded with Mild steel flat iron 25Millimeter x 5meter size on back on edges. The lower plate will be welded with Mild steel angle iron frame of 25 Millimeter x 25 Millimeter x 5 Millimeter. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75Millimeter x 75 Millimeter of 12 Steel wire Gause sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450Millimeter x 450Millimeter x 600Millimeter, 600Millimeter below ground level. The top most diamond plate will be welded to middle plate by 47Millimeter x 47Millimeter of 12 Steel wire Gauge steel plate tube. All Mild steel will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 'Logo' of Mukhya Mantri Gram Sadak Yojana Project And As Directed by Engineer Incharge

1

19266

19266.15

... More
Providing and erecting direction and place identification of semi reflective sign boards as per IRC-67 made of 2 mm thick M.S. Sheet duly stove enameled paint white colour in front and grey colour on back with reflective border of 70 mm width and required message, letters, figures with reflective tape of engineering grade as per MORD specifications of required shade and colour. Supported and welded on two nos. 47 mm x 47 mm of 12 SWG square tube of 3050 mm height duly strengthened by 25 mm x 5 mm MS flat iron on edges on back firmly fixed to the ground by means of properly designed foundations with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701

8

34519

4314.95

... More
Providing and fixing Cautionary/Warning sign boards in Equilateral Triangle size of mm made out of mm aluminum sheet bonded with white retro reflective sheeting of Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3 Supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with grey stove enamel paint and supported on one no. of M. S. angle iron post of size 65 mm X 65 mm X 6 mm, 3.45 m long, duly painted with with flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in M25 grade concrete block of size 60cm X 60cm X 75cm including transportation etc; complete. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier. And As Directed by Engineer Incharge

34

136695

4020.45

... More
Providing and fixing of retro- reflectorised informatory sign board rectangular/Square in shape having area less than 0.9 One Square Meterr made out of mm aluminum sheet bonded with white retro reflective sheeting of Class ( Type IV High intensity micro- prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3, supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with two coats of grey stove enamel paint and supported on one no. mild steel angle iron post 75 mm x 75 mm x 6 mm, 3.5 mt long firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing The angle iron post shall be duly painted with one coat of epoxy primer and two coats of epoxy finish paints having alternate black and white bands of 25 cm width including GI fixures and transportation etc.complete.The nut bolts of board with angle iron post/supporting structure after fixing at site has to be electrically welded. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) sheeting shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier. 600 x 450 milimeter Rectangular And As Directed by Engineer Incharge

2.7

27405

10150.35

... More
Providing and fixing Mandatory/Regulatory sign boards in circular shape of mm dia made out of mm aluminum sheet bonded with white retro reflective sheeting of Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3 Supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with grey stove enamel paint and supported on one no. of M. S. angle iron post of size 65 mm X 65 mm X 6 mm, 3.45 m long, duly painted with with flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in M25 grade concrete block of size 60cm X 60cm X 75cm including transportation etc; complete. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier. 600mm circular And As Directed by Engineer Incharge

40

189672

4741.8

... More
Providing and Laying hot applied thermoplastic road marking strip on Bituminous Surface of specified shade/ colour of 2.5 mm thick including 1.5 Refractive index reflectorizing glass beads @ 250gm/sqm .Thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC 35:2015. Initial Dry reflectivity RL shall be 250 mcd/sqm/lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/sqm/ lux and Qd of 100 mcd/sqm/ lux measured at the end of 2 years by means of a Standard Reflectometer of Zehntner, Easylux, Delta make capable of measuring RL & QD both according to IRC 35:2015 clause 15.5. The finished surface to be level, uniform, and free from streaks and holes complete as per direction of Engineer-in-charge and in accordance with applicable specifications.(Refer MORTH Clause 803 for technical Specification and Performance for IRC 35:2015) And As Directed by Engineer Incharge

809

565733

699.3

... More
Road Delineators: Supplying and installation of delineators (Roadway Indicators, Hazard markers, Object markers) 80 to 100 cm high above ground level, painted black and white in 15cm wide strips, fitted with 80x100mm rectangular or 75mm dia. Circular reflectorised panels at the top, buried or pressed into the ground and confirming to I.R.C. 79 and the drawings And As Directed by Engineer Incharge

65

56101

863.1

... More
Providing and fixing in position Pipe Railing consisting of IS Rolled steel joist posts designation IS MB 100 (100x75) at 2.5 m interval and three rows of 50 mm dia steel pipes (light) including fixing in position on bridge deck complete as per drawing and technical specifications Clause 1208.2 And As Directed by Engineer Incharge

240

526656

2194.4

... More
Painting two coats including prime coat with epoxy paint of approved brand on concrete/steel surfaces after through cleaning of surface to give an even shade as per drawing and Technical Specification Clause 1701 And As Directed by Engineer Incharge

3.24

562

173.75

... More
White washing two coats on parapet walls and white washing and geru lime painting to tree trunks including preparation of surface by cleaning scraping etc. complete And As Directed by Engineer Incharge

30

819

27.3

... More
A,W : Metal Beam Crash Barrier (Providing and erecting a "W "metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip cess, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810) And As Directed by Engineer Incharge

190

979944

5157.6

... More
Providing and Laying of 2 or more sets (6Nos. each set) Dual Ribs Pattern Rumble Markings on roads with vehicular speeds of more than 50 Km/hr laid as per the spacing recommended for each set under Table11.1 and Fig.11.2 of IRC35:2015 using Plastirib 2K, or equivalent 2 component cold plastic profiled material. Each Dual Rib pattern rumble marking shall have width of 500mm. Each dual rib pattern rumble marking shall have 2 ribs each of Width of 100mm and height 20mm. Gap between two ribs shall be 300mm. Each rumble marking shall be made complete with drop on Soild Plus reflective glass beads @ 300 gm / One Square Metre spread throughout the surface of marking. The finished surface to be levelled,uniform and free from streaks and holes,including surface cleaning and cost of all materials etc. complete. And As Directed by Engineer Incharge.

9

40946

4549.65

... More
I) Improvement of Road from Vita to Chinchani (M) (Khairatimala) Road (Part Chinchani (m) to Khairatimala Road) Ch 1/200 to 4/000, Taluka -Khanapur, District:-Sangli, Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 milimeter, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 meter including removal and disposal of top organic soil not exceeding 150 milimeter in thickness as per Technical Specification Ministry Of Rural Development 2014 Clause 201. By mechnical means (A) In area Non of thorny jungle And As Directed by Engineer Incharge

0.84

23400

27857.45

... More
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 milimeter, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 meter including removal and disposal of top organic soil not exceeding 150 milimeter in thickness as per Technical Specification Ministry Of Rural Development 2014 Clause 201.By mechnical means (B) In area of thorny jungle And As Directed by Engineer Incharge

0.56

19391

34627.65

... More
Excavation for roadwork in soil with hydraulic excavator of 0.9 cubicmeter bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with a lift upto 1.5 meter and lead more than 100 meter as per Technical Specification Ministry Of Rural Development 2014 Clause 302.3 And As Directed by Engineer Incharge

2475.52

192224

77.65

... More
Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cubicmeter bucket capacity including cutting and loading in tippers, transporting to embankment site with a lift upto 1.5 meter and lead above 100 meter, trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections as per Technical Specification Ministry Of Rural Development 2014 Clause 302.3.5 And As Directed by Engineer Incharge

900.47

102743

114.1

... More
Excavation for roadway in hard rock (requiring blasting) by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross-sections, loading and disposal of cut rock with a lift upto 1.5 meter and leads upto 1000 meter as per Technical Specification Clause 302.3.5 And As Directed by Engineer Incharge

112.33

17753

158.05

... More
Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal with a lift upto 1.5 meter and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification Clause 302.3.5 And As Directed by Engineer Incharge

48.15

26605

552.55

... More
Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Ministry Of Rural Development 2014 Clause 301.5 And As Directed by Engineer Incharge

2858.05

251651

88.05

... More
Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 And As Directed by Engineer Incharge

3495.87

1959257

560.45

... More
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 as per Technical Specification Ministry Of Rural Development 2014 Clause 303.1. And As Directed by Engineer Incharge

2635.5

1755111

665.95

... More
Loosening, Levelling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 milimeter, mixed with water at optimum moisture content and then compacted by rolling so as to achieve minimum dry density as given in Tables 300.1 and 300.2 for embankment construction as per Technical Specification Clause 301.4.1.And As Directed by Engineer Incharge And As Directed by Engineer Incharge

3570

123343

34.55

... More
Setting Out And As Directed by Engineer Incharge

2.8

73534

26262.49

... More
Construction of Granular sub-base grade -II by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator and compacting with vibretary wheel roller to achieve the desired density, complete as per Technical Specification Ministry Of Rural Development 2014 Clause 401. And As Directed by Engineer Incharge

1209.51

2856318

2361.55

... More
Providing and laying White Topping/Short Paneled Concrete as per IRC-SP 76-2015 (Existing surface preparation to be done if necessary either by milling or leveling course with DLC to correct surface profile and to be paid separately) with un reinforced M-40 grade Pavement Quality Concrete using Ordinary Portland Cement 43/53 Grade OR Portland Pozzolona Cement IS-1489 at 425kg/cum, coarse aggregate, fine aggregate(VSI) and Admixture confirming to IS 9130-1999 (R-2004) polymeric synthetic fiber as per ASTM (1116) such as polyester / polyethylene / polypropylene / Glass fiber at 1.20 kg/cum, mixed in batching and mixing plant or weigh batcher as per approved mix design to achieve minimum flexural strength or modulus of rupture of concrete 4.50 MPa at 28 days limiting maximum water cement ratio to 0.40, transported to site, laid with fixed form/ slip form paver finisher (preferably with slip form paver finisher), spread, vibrated, compacted and finished in a continuous operation to the lines and grades as per drawing, texture finishing of surface, spraying two layers of curing compound, curing with water sprayed on hessian cloth covered over concrete surface, groove cutting grid 1m x 1m or as directed by Engineer Incharge to a depth of 1/3 to 1/4 of the Thickness and of width 3-5 mm as per design including cost of all material, side form work, labour and machineries etc. complete as per specifications.(Excluding Dowel Bars and Tie Bars) ( Including Polythene sheet 125 micron) And As Directed by Engineer Incharge

1680.9

13526370

8047.1

... More
Providing & Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate ( natural sand/ VSI grade finely washed crushed sand) conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, , cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days,mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts,laid with a paver with electronic sensor /by suitable means as approved by Engineer-in charge , compacting with vibratory roller, finishing, curing and including preparation of sub-grade surface if required etc. complete. And As Directed by Engineer Incharge

1208.61

4645534

3843.7

... More
Providing and fixing in position 25mm dia anti corrosive MS dowel bars of required Dia. 60 cms. Long and at 30.00 cm. C/C and wherever directed including handling. straightening, necessary cutting supported by chairs with proper alignment with half length covered by polyethene sheathing including cap etc. complete.And As Directed by Engineer Incharge

364

88779

243.9

... More
Providing and fixing in position anticorrosive TMT FE 500 tie bars of 12 mm dia. 70 cms. long and at 30.00 cm. C/C and wherever directed including handling, straightening necessary cutting, handling, straightening, supported by assembly of TMT FE 500, chairs with proper alignment etc. complete.And As Directed by Engineer Incharge

9636

642239

66.65

... More
Removing all types of Hume pipes and stacking within a lead of 1000 m including Earthwork and Dismantling of Masonry Works as per Technical Specification MORD 2014 Clause 202. Upto 600 mm dia Hume pipe And As Directed by Engineer Incharge

45

27787

617.5

... More
Earthwork in excavation for structures as per drawing and technical specifications Ministry Of Rural Development 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 meter, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary soil And As Directed by Engineer Incharge

496.54

349440

703.75

... More
Earthwork in excavation for structures as per drawing and technical specifications Ministry Of Rural Development 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 meter, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary rock (not requiring blasting) Upto 3 meter depth And As Directed by Engineer Incharge

210.7

185352

879.7

... More
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Hard rock (blasting prohibited) Upto 3 meter depth And As Directed by Engineer Incharge

62.48

63117

1010.2

... More
Filling in foundation trenches as per drawing and technical specification Clause 305.3.9 Rubble soling with Rubble And As Directed by Engineer Incharge

37.94

89086

2348.1

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 Plane cement concreate grade M 10 Nominal mix 1:3:6 And As Directed by Engineer Incharge

98.46

662950

6733.2

... More
Providing concrete for plain/reinforced concrete in sub structure complete as per drawings and technical specifications Ministry Of Rural Development 2014 Clause 802, 803, 804, 805, 806, 807, 1202 & 1203, 1204 Plain cement concreate grade M 15 Nominal mix (1:2.5:5) And As Directed by Engineer Incharge

599.95

4188970

6982.2

... More
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. B. 1000 milimeter Non pressure 3 Class As per Technical Specification Ministry Of Rural Development 2014 Cluase No. 1100 And As Directed by Engineer Incharge

120

951270

7927.25

... More
Providing and laying reinforced cement concrete pipe Non pressure2 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. D. 600 milimeter Non pressure 2 Class As per Technical Specification Ministry Of Rural Development 2014 Cluase No. 1100 And As Directed by Engineer Incharge

195

559581

2869.65

... More
Providing weepholes in brick masonry / stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 milimeter dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7 A.C. pipe 100 milimeter Dia And As Directed by Engineer Incharge

140

44604

318.6

... More
Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1303 And As Directed by Engineer Incharge

142.32

335128

2354.75

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per Indian Road Congress:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Ministry Of Rural Development 2014 Clause 1703 Ordinary Kilometer Stone (Precast) And As Directed by Engineer Incharge

3

9367

3122.6

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per Indian Road Congress:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Ministry Of Rural Development 2014 Clause 1703 200 meter stone (precast) And As Directed by Engineer Incharge

12

10509

875.75

... More
Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per Indian Road Congress:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704. And As Directed by Engineer Incharge

269

237365

882.4

... More
MMGSY / PMGSY Citizen' s information Board- Providing and fixing of typical PMGSY Retro Reflective information board as per as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circular and drawing. Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottom duly rivetted with MS angles of 35 x 35 x 5 mm thick M.S angle shall be welded by two vertical M.S angle of 5 mm thick to 75 mm x 75 mm of 12 SWG square tubes / 75mm Dia Pipe posts duly embedded in cement concrete M-20 grade blocks of 600mm x 600mm x 75mm, below ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circular no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4 and as directed by Engineer-In-charge. . A warranty for 5 / 7 years for the Retro reflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor And As Directed by Engineer Incharge.

2

60238

30119.25

... More
Providing and fixing of typical Mukhya Mantri Gram Sadak Yojana informatory sign board with Logo as per Ministry Of Rural Development specifications and drawing. Three Mild steel Plates of 1.6 mm thick, top and middle plate duly welded with Mild steel flat iron 25Millimeter x 5meter size on back on edges. The lower plate will be welded with Mild steel angle iron frame of 25 Millimeter x 25 Millimeter x 5 Millimeter. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75Millimeter x 75 Millimeter of 12 Steel wire Gause sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450Millimeter x 450Millimeter x 600Millimeter, 600Millimeter below ground level. The top most diamond plate will be welded to middle plate by 47Millimeter x 47Millimeter of 12 Steel wire Gauge steel plate tube. All Mild steel will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 'Logo' of Mukhya Mantri Gram Sadak Yojana Project And As Directed by Engineer Incharge

2

38532

19266.15

... More
Providing and erecting direction and place identification of semi reflective sign boards as per IRC-67 made of 2 mm thick M.S. Sheet duly stove enameled paint white colour in front and grey colour on back with reflective border of 70 mm width and required message, letters, figures with reflective tape of engineering grade as per MORD specifications of required shade and colour. Supported and welded on two nos. 47 mm x 47 mm of 12 SWG square tube of 3050 mm height duly strengthened by 25 mm x 5 mm MS flat iron on edges on back firmly fixed to the ground by means of properly designed foundations with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701 And As Directed by Engineer Incharge

6

25889

4314.95

... More
Providing and fixing Cautionary/Warning sign boards in Equilateral Triangle size of mm made out of mm aluminum sheet bonded with white retro reflective sheeting of Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3 Supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with grey stove enamel paint and supported on one no. of M. S. angle iron post of size 65 mm X 65 mm X 6 mm, 3.45 m long, duly painted with with flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in M25 grade concrete block of size 60cm X 60cm X 75cm including transportation etc; complete. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier. And As Directed by Engineer Incharge

29

116593

4020.45

... More
Providing and fixing of retro- reflectorised informatory sign board rectangular/Square in shape having area less than 0.9 One Square Meterr made out of mm aluminum sheet bonded with white retro reflective sheeting of Class ( Type IV High intensity micro- prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3, supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with two coats of grey stove enamel paint and supported on one no. mild steel angle iron post 75 mm x 75 mm x 6 mm, 3.5 mt long firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing The angle iron post shall be duly painted with one coat of epoxy primer and two coats of epoxy finish paints having alternate black and white bands of 25 cm width including GI fixures and transportation etc.complete.The nut bolts of board with angle iron post/supporting structure after fixing at site has to be electrically welded. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) sheeting shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier. 600 x 450 milimeter Rectangular And As Directed by Engineer Incharge

1.62

16443

10150.35

... More
Providing and fixing Mandatory/Regulatory sign boards in circular shape of mm dia made out of mm aluminum sheet bonded with white retro reflective sheeting of Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3 Supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with grey stove enamel paint and supported on one no. of M. S. angle iron post of size 65 mm X 65 mm X 6 mm, 3.45 m long, duly painted with with flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in M25 grade concrete block of size 60cm X 60cm X 75cm including transportation etc; complete. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier. 600mm circular And As Directed by Engineer Incharge

31

146995

4741.8

... More
Providing and Laying hot applied thermoplastic road marking strip on Bituminous Surface of specified shade/ colour of 2.5 mm thick including 1.5 Refractive index reflectorizing glass beads @ 250gm/sqm .Thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC 35:2015. Initial Dry reflectivity RL shall be 250 mcd/sqm/lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/sqm/ lux and Qd of 100 mcd/sqm/ lux measured at the end of 2 years by means of a Standard Reflectometer of Zehntner, Easylux, Delta make capable of measuring RL & QD both according to IRC 35:2015 clause 15.5. The finished surface to be level, uniform, and free from streaks and holes complete as per direction of Engineer-in-charge and in accordance with applicable specifications.(Refer MORTH Clause 803 for technical Specification and Performance for IRC 35:2015) And As Directed by Engineer Incharge

569

397901

699.3

... More
Road Delineators: Supplying and installation of delineators (Roadway Indicators, Hazard markers, Object markers) 80 to 100 cm high above ground level, painted black and white in 15cm wide strips, fitted with 80x100mm rectangular or 75mm dia. Circular reflectorised panels at the top, buried or pressed into the ground and confirming to I.R.C. 79 and the drawings And As Directed by Engineer Incharge

40

34524

863.1

... More
Providing and fixing in position Pipe Railing consisting of IS Rolled steel joist posts designation IS MB 100 (100x75) at 2.5 m interval and three rows of 50 mm dia steel pipes (light) including fixing in position on bridge deck complete as per drawing and technical specifications Clause 1208.2 And As Directed by Engineer Incharge

30

65832

2194.4

... More
Painting two coats including prime coat with epoxy paint of approved brand on concrete/steel surfaces after through cleaning of surface to give an even shade as per drawing and Technical Specification Clause 1701 And As Directed by Engineer Incharge

0.84

145

173.75

... More
White washing two coats on parapet walls and white washing and geru lime painting to tree trunks including preparation of surface by cleaning scraping etc. complete And As Directed by Engineer Incharge

9

245

27.3

... More
A,W : Metal Beam Crash Barrier (Providing and erecting a "W "metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip cess, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810) And As Directed by Engineer Incharge

70

361032

5157.6

... More
Providing and Laying of 2 or more sets (6Nos. each set) Dual Ribs Pattern Rumble Markings on roads with vehicular speeds of more than 50 Km/hr laid as per the spacing recommended for each set under Table11.1 and Fig.11.2 of IRC35:2015 using Plastirib 2K, or equivalent 2 component cold plastic profiled material. Each Dual Rib pattern rumble marking shall have width of 500mm. Each dual rib pattern rumble marking shall have 2 ribs each of Width of 100mm and height 20mm. Gap between two ribs shall be 300mm. Each rumble marking shall be made complete with drop on Soild Plus reflective glass beads @ 300 gm / One Square Metre spread throughout the surface of marking. The finished surface to be levelled,uniform and free from streaks and holes,including surface cleaning and cost of all materials etc. complete. And As Directed by Engineer Incharge.

9

40946

4549.65

... More
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. And As Directed by Engineer Incharge

45.5

31390

689.9

... More
Providing groove to required size at specified location as directed by Engineer, at junction of brick masonry wall and R.C.C beams or Column, at junction of composite masonry, including scaffolding, finishing, curing etc. Complete And As Directed by Engineer Incharge

13.65

670

49.1

... More
Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete And As Directed by Engineer Incharge

12.6

754

59.85

... More
J) Improvement of Road from Hingangade to Salunkhewasti Ch 0/000 to 2/000 Taluka -Khanapur, District:-Sangli, Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 milimeter, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 meter including removal and disposal of top organic soil not exceeding 150 milimeter in thickness as per Technical Specification Ministry Of Rural Development 2014 Clause 201. By mechnical means (A) In area Non of thorny jungle And As Directed by Engineer Incharge

0.6

16714

27857.35

... More
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 milimeter, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 meter including removal and disposal of top organic soil not exceeding 150 milimeter in thickness as per Technical Specification Ministry Of Rural Development 2014 Clause 201.By mechnical means (B) In area of thorny jungle And As Directed by Engineer Incharge

0.4

13851

34627.65

... More
Excavation for roadwork in soil with hydraulic excavator of 0.9 cubicmeter bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with a lift upto 1.5 meter and lead more than 100 meter as per Technical Specification Ministry Of Rural Development 2014 Clause 302.3 And As Directed by Engineer Incharge

3960.76

307553

77.65

... More
Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cubicmeter bucket capacity including cutting and loading in tippers, transporting to embankment site with a lift upto 1.5 meter and lead above 100 meter, trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections as per Technical Specification Ministry Of Rural Development 2014 Clause 302.3.5 And As Directed by Engineer Incharge

967.29

110367

114.1

... More
Scarifying existing bituminous surface to a depth of 150 mm and disposal of scarified material with a lift upto 3 m and leads upto 1000 m as per Technical Specification Clause 301.4. as per Technical Specification Clause 301.4 And As Directed by Engineer Incharge

900

14940

16.6

... More
Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Ministry Of Rural Development 2014 Clause 301.5 And As Directed by Engineer Incharge

1998.89

176002

88.05

... More
Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 And As Directed by Engineer Incharge

3072.94

1923814

626.05

... More
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 as per Technical Specification Ministry Of Rural Development 2014 Clause 303.1. And As Directed by Engineer Incharge

1823.09

1338879

734.4

... More
Loosening, Levelling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 milimeter, mixed with water at optimum moisture content and then compacted by rolling so as to achieve minimum dry density as given in Tables 300.1 and 300.2 for embankment construction as per Technical Specification Clause 301.4.1.And As Directed by Engineer Incharge And As Directed by Engineer Incharge

2167.5

74887

34.55

... More
Setting Out And As Directed by Engineer Incharge

2

52317

26158.69

... More
Construction of Granular sub-base grade -II by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator and compacting with vibretary wheel roller to achieve the desired density, complete as per Technical Specification Ministry Of Rural Development 2014 Clause 401. And As Directed by Engineer Incharge

780.66

1725727

2210.6

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kilonewton static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Water bound macadum Grading 2 as per Technical Specification Ministry Of Rural Development 2014 Clause 405. For - By Mechanical Means And As Directed by Engineer Incharge

30.58

73093

2390.05

... More
Providing and laying White Topping/Short Paneled Concrete as per IRC-SP 76-2015 (Existing surface preparation to be done if necessary either by milling or leveling course with DLC to correct surface profile and to be paid separately) with un reinforced M-40 grade Pavement Quality Concrete using Ordinary Portland Cement 43/53 Grade OR Portland Pozzolona Cement IS-1489 at 425kg/cum, coarse aggregate, fine aggregate(VSI) and Admixture confirming to IS 9130-1999 (R-2004) polymeric synthetic fiber as per ASTM (1116) such as polyester / polyethylene / polypropylene / Glass fiber at 1.20 kg/cum, mixed in batching and mixing plant or weigh batcher as per approved mix design to achieve minimum flexural strength or modulus of rupture of concrete 4.50 MPa at 28 days limiting maximum water cement ratio to 0.40, transported to site, laid with fixed form/ slip form paver finisher (preferably with slip form paver finisher), spread, vibrated, compacted and finished in a continuous operation to the lines and grades as per drawing, texture finishing of surface, spraying two layers of curing compound, curing with water sprayed on hessian cloth covered over concrete surface, groove cutting grid 1m x 1m or as directed by Engineer Incharge to a depth of 1/3 to 1/4 of the Thickness and of width 3-5 mm as per design including cost of all material, side form work, labour and machineries etc. complete as per specifications.(Excluding Dowel Bars and Tie Bars) ( Including Polythene sheet 125 micron) And As Directed by Engineer Incharge

1198.9

10085086

8411.95

... More
Providing & Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate ( natural sand/ VSI grade finely washed crushed sand) conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, , cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days,mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts,laid with a paver with electronic sensor /by suitable means as approved by Engineer-in charge , compacting with vibratory roller, finishing, curing and including preparation of sub-grade surface if required etc. complete. And As Directed by Engineer Incharge

860.76

3677683

4272.6

... More
Providing and fixing in position 25mm dia anti corrosive MS dowel bars of required Dia. 60 cms. Long and at 30.00 cm. C/C and wherever directed including handling. straightening, necessary cutting supported by chairs with proper alignment with half length covered by polyethene sheathing including cap etc. complete.And As Directed by Engineer Incharge

260

63414

243.9

... More
Providing and fixing in position anticorrosive TMT FE 500 tie bars of 12 mm dia. 70 cms. long and at 30.00 cm. C/C and wherever directed including handling, straightening necessary cutting, handling, straightening, supported by assembly of TMT FE 500, chairs with proper alignment etc. complete.And As Directed by Engineer Incharge

6770

451220

66.65

... More
Earthwork in excavation for structures as per drawing and technical specifications Ministry Of Rural Development 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 meter, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary soil And As Directed by Engineer Incharge

215.37

151566

703.75

... More
Earthwork in excavation for structures as per drawing and technical specifications Ministry Of Rural Development 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 meter, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary rock (not requiring blasting) Upto 3 meter depth And As Directed by Engineer Incharge

104.61

92025

879.7

... More
Filling in foundation trenches as per drawing and technical specification Clause 305.3.9 Rubble soling with Rubble And As Directed by Engineer Incharge

22.26

52268

2348.1

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 Plane cement concreate grade M 10 Nominal mix 1:3:6 And As Directed by Engineer Incharge

31.74

208355

6564.45

... More
Providing concrete for plain/reinforced concrete in sub structure complete as per drawings and technical specifications Ministry Of Rural Development 2014 Clause 802, 803, 804, 805, 806, 807, 1202 & 1203, 1204 Plain cement concreate grade M 15 Nominal mix (1:2.5:5) And As Directed by Engineer Incharge

241.83

1652206

6832.1

... More
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. B. 1000 milimeter Non pressure 3 Class As per Technical Specification Ministry Of Rural Development 2014 Cluase No. 1100 And As Directed by Engineer Incharge

52.5

416180

7927.25

... More
Providing and laying reinforced cement concrete pipe Non pressure2 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. D. 600 milimeter Non pressure 2 Class As per Technical Specification Ministry Of Rural Development 2014 Cluase No. 1100 And As Directed by Engineer Incharge

140

401751

2869.65

... More
Providing and laying cement concrete wearing course M30 grade Excluding reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3 And As Directed by Engineer Incharge

7.43

110123

14821.5

... More
Providing weepholes in brick masonry / stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 milimeter dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7 A.C. pipe 100 milimeter Dia And As Directed by Engineer Incharge

90

28674

318.6

... More
Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1303 And As Directed by Engineer Incharge

92.35

204328

2212.55

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per Indian Road Congress:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Ministry Of Rural Development 2014 Clause 1703 Ordinary Kilometer Stone (Precast) And As Directed by Engineer Incharge

3

9367

3122.6

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per Indian Road Congress:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Ministry Of Rural Development 2014 Clause 1703 200 meter stone (precast) And As Directed by Engineer Incharge

8

7006

875.75

... More
Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per Indian Road Congress:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704. And As Directed by Engineer Incharge

190

167656

882.4

... More
MMGSY / PMGSY Citizen' s information Board- Providing and fixing of typical PMGSY Retro Reflective information board as per as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circular and drawing. Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottom duly rivetted with MS angles of 35 x 35 x 5 mm thick M.S angle shall be welded by two vertical M.S angle of 5 mm thick to 75 mm x 75 mm of 12 SWG square tubes / 75mm Dia Pipe posts duly embedded in cement concrete M-20 grade blocks of 600mm x 600mm x 75mm, below ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circular no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4 and as directed by Engineer-In-charge. . A warranty for 5 / 7 years for the Retro reflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor. And As Directed by Engineer Incharge

2

60238

30119.25

... More
Providing and fixing of typical Mukhya Mantri Gram Sadak Yojana informatory sign board with Logo as per Ministry Of Rural Development specifications and drawing. Three Mild steel Plates of 1.6 mm thick, top and middle plate duly welded with Mild steel flat iron 25Millimeter x 5meter size on back on edges. The lower plate will be welded with Mild steel angle iron frame of 25 Millimeter x 25 Millimeter x 5 Millimeter. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75Millimeter x 75 Millimeter of 12 Steel wire Gause sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450Millimeter x 450Millimeter x 600Millimeter, 600Millimeter below ground level. The top most diamond plate will be welded to middle plate by 47Millimeter x 47Millimeter of 12 Steel wire Gauge steel plate tube. All Mild steel will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 'Logo' of Mukhya Mantri Gram Sadak Yojana Project And As Directed by Engineer Incharge

1

19266

19266.15

... More
Providing and erecting direction and place identification of semi reflective sign boards as per IRC-67 made of 2 mm thick M.S. Sheet duly stove enameled paint white colour in front and grey colour on back with reflective border of 70 mm width and required message, letters, figures with reflective tape of engineering grade as per MORD specifications of required shade and colour. Supported and welded on two nos. 47 mm x 47 mm of 12 SWG square tube of 3050 mm height duly strengthened by 25 mm x 5 mm MS flat iron on edges on back firmly fixed to the ground by means of properly designed foundations with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701 And As Directed by Engineer Incharge

6

25889

4314.95

... More
Providing and fixing Cautionary/Warning sign boards in Equilateral Triangle size of mm made out of mm aluminum sheet bonded with white retro reflective sheeting of Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3 Supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with grey stove enamel paint and supported on one no. of M. S. angle iron post of size 65 mm X 65 mm X 6 mm, 3.45 m long, duly painted with with flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in M25 grade concrete block of size 60cm X 60cm X 75cm including transportation etc; complete. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier. And As Directed by Engineer Incharge

18

72368

4020.45

... More
Providing and fixing of retro- reflectorised informatory sign board rectangular/Square in shape having area less than 0.9 One Square Meterr made out of mm aluminum sheet bonded with white retro reflective sheeting of Class ( Type IV High intensity micro- prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3, supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with two coats of grey stove enamel paint and supported on one no. mild steel angle iron post 75 mm x 75 mm x 6 mm, 3.5 mt long firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing The angle iron post shall be duly painted with one coat of epoxy primer and two coats of epoxy finish paints having alternate black and white bands of 25 cm width including GI fixures and transportation etc.complete.The nut bolts of board with angle iron post/supporting structure after fixing at site has to be electrically welded. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) sheeting shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier. 600 x 450 milimeter Rectangular And As Directed by Engineer Incharge

1.35

13702

10150.35

... More
Providing and fixing Mandatory/Regulatory sign boards in circular shape of mm dia made out of mm aluminum sheet bonded with white retro reflective sheeting of Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3 Supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with grey stove enamel paint and supported on one no. of M. S. angle iron post of size 65 mm X 65 mm X 6 mm, 3.45 m long, duly painted with with flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in M25 grade concrete block of size 60cm X 60cm X 75cm including transportation etc; complete. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier. 600mm circular And As Directed by Engineer Incharge

19

90094

4741.8

... More
Providing and Laying hot applied thermoplastic road marking strip on Bituminous Surface of specified shade/ colour of 2.5 mm thick including 1.5 Refractive index reflectorizing glass beads @ 250gm/sqm .Thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC 35:2015. Initial Dry reflectivity RL shall be 250 mcd/sqm/lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/sqm/ lux and Qd of 100 mcd/sqm/ lux measured at the end of 2 years by means of a Standard Reflectometer of Zehntner, Easylux, Delta make capable of measuring RL & QD both according to IRC 35:2015 clause 15.5. The finished surface to be level, uniform, and free from streaks and holes complete as per direction of Engineer-in-charge and in accordance with applicable specifications.(Refer MORTH Clause 803 for technical Specification and Performance for IRC 35:2015) And As Directed by Engineer Incharge

406

283915

699.3

... More
Road Delineators: Supplying and installation of delineators (Roadway Indicators, Hazard markers, Object markers) 80 to 100 cm high above ground level, painted black and white in 15cm wide strips, fitted with 80x100mm rectangular or 75mm dia. Circular reflectorised panels at the top, buried or pressed into the ground and confirming to I.R.C. 79 and the drawings And As Directed by Engineer Incharge

22

18988

863.1

... More
Providing and fixing in position Pipe Railing consisting of IS Rolled steel joist posts designation IS MB 100 (100x75) at 2.5 m interval and three rows of 50 mm dia steel pipes (light) including fixing in position on bridge deck complete as per drawing and technical specifications Clause 1208.2 And As Directed by Engineer Incharge

15

32916

2194.4

... More
Painting two coats including prime coat with epoxy paint of approved brand on concrete/steel surfaces after through cleaning of surface to give an even shade as per drawing and Technical Specification Clause 1701 And As Directed by Engineer Incharge

0.6

104

173.75

... More
White washing two coats on parapet walls and white washing and geru lime painting to tree trunks including preparation of surface by cleaning scraping etc. complete And As Directed by Engineer Incharge

19

518

27.3

... More
A,W : Metal Beam Crash Barrier (Providing and erecting a "W "metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip cess, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810) And As Directed by Engineer Incharge

70

361032

5157.6

... More
Providing and Laying of 2 or more sets (6Nos. each set) Dual Ribs Pattern Rumble Markings on roads with vehicular speeds of more than 50 Km/hr laid as per the spacing recommended for each set under Table11.1 and Fig.11.2 of IRC35:2015 using Plastirib 2K, or equivalent 2 component cold plastic profiled material. Each Dual Rib pattern rumble marking shall have width of 500mm. Each dual rib pattern rumble marking shall have 2 ribs each of Width of 100mm and height 20mm. Gap between two ribs shall be 300mm. Each rumble marking shall be made complete with drop on Soild Plus reflective glass beads @ 300 gm / One Square Metre spread throughout the surface of marking. The finished surface to be levelled,uniform and free from streaks and holes,including surface cleaning and cost of all materials etc. complete. And As Directed by Engineer Incharge.

6

27297

4549.65

... More
K) Improvement of Road from Hatnoor to Pirdeo road Ch 0/000 to 2/780, Taluka -Tasgaon, District:-Sangli, Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 milimeter, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 meter including removal and disposal of top organic soil not exceeding 150 milimeter in thickness as per Technical Specification Ministry Of Rural Development 2014 Clause 201. By mechnical means (A) In area Non of thorny jungle And As Directed by Engineer Incharge

0.98

26000

26530.8

... More
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 milimeter, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 meter including removal and disposal of top organic soil not exceeding 150 milimeter in thickness as per Technical Specification Ministry Of Rural Development 2014 Clause 201.By mechnical means (B) In area of thorny jungle And As Directed by Engineer Incharge

0.42

15547

37018.7

... More
Excavation for roadwork in soil with hydraulic excavator of 0.9 cubicmeter bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with a lift upto 1.5 meter and lead more than 100 meter as per Technical Specification Ministry Of Rural Development 2014 Clause 302.3 And As Directed by Engineer Incharge

4856.34

359126

73.95

... More
Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cubicmeter bucket capacity including cutting and loading in tippers, transporting to embankment site with a lift upto 1.5 meter and lead above 100 meter, trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections as per Technical Specification Ministry Of Rural Development 2014 Clause 302.3.5 And As Directed by Engineer Incharge

1944.95

211416

108.7

... More
Excavation for roadway in hard rock (requiring blasting) by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross-sections, loading and disposal of cut rock with a lift upto 1.5 meter and leads upto 1000 meter as per Technical Specification Clause 302.3.5 And As Directed by Engineer Incharge

136.35

20527

150.55

... More
Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Ministry Of Rural Development 2014 Clause 301.5 And As Directed by Engineer Incharge

4045.69

339231

83.85

... More
Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 And As Directed by Engineer Incharge

2856.86

1721256

602.5

... More
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 as per Technical Specification Ministry Of Rural Development 2014 Clause 303.1. And As Directed by Engineer Incharge

2533.28

1788369

705.95

... More
Loosening, Levelling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 milimeter, mixed with water at optimum moisture content and then compacted by rolling so as to achieve minimum dry density as given in Tables 300.1 and 300.2 for embankment construction as per Technical Specification Clause 301.4.1.And As Directed by Engineer Incharge And As Directed by Engineer Incharge

3336

109754

32.9

... More
Setting Out And As Directed by Engineer Incharge

2.78

72131

25946.49

... More
Construction of Granular sub-base grade -II by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator and compacting with vibretary wheel roller to achieve the desired density, complete as per Technical Specification Ministry Of Rural Development 2014 Clause 401. And As Directed by Engineer Incharge

1256.07

2805243

2233.35

... More
Providing and laying White Topping/Short Paneled Concrete as per IRC-SP 76-2015 (Existing surface preparation to be done if necessary either by milling or leveling course with DLC to correct surface profile and to be paid separately) with un reinforced M-40 grade Pavement Quality Concrete using Ordinary Portland Cement 43/53 Grade OR Portland Pozzolona Cement IS-1489 at 425kg/cum, coarse aggregate, fine aggregate(VSI) and Admixture confirming to IS 9130-1999 (R-2004) polymeric synthetic fiber as per ASTM (1116) such as polyester / polyethylene / polypropylene / Glass fiber at 1.20 kg/cum, mixed in batching and mixing plant or weigh batcher as per approved mix design to achieve minimum flexural strength or modulus of rupture of concrete 4.50 MPa at 28 days limiting maximum water cement ratio to 0.40, transported to site, laid with fixed form/ slip form paver finisher (preferably with slip form paver finisher), spread, vibrated, compacted and finished in a continuous operation to the lines and grades as per drawing, texture finishing of surface, spraying two layers of curing compound, curing with water sprayed on hessian cloth covered over concrete surface, groove cutting grid 1m x 1m or as directed by Engineer Incharge to a depth of 1/3 to 1/4 of the Thickness and of width 3-5 mm as per design including cost of all material, side form work, labour and machineries etc. complete as per specifications.(Excluding Dowel Bars and Tie Bars) ( Including Polythene sheet 125 micron) And As Directed by Engineer Incharge

1655.8

12701641

7671

... More
Providing & Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate ( natural sand/ VSI grade finely washed crushed sand) conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, , cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days,mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts,laid with a paver with electronic sensor /by suitable means as approved by Engineer-in charge , compacting with vibratory roller, finishing, curing and including preparation of sub-grade surface if required etc. complete. And As Directed by Engineer Incharge

1191.27

4357189

3657.6

... More
Providing and fixing in position 25mm dia anti corrosive MS dowel bars of required Dia. 60 cms. Long and at 30.00 cm. C/C and wherever directed including handling. straightening, necessary cutting supported by chairs with proper alignment with half length covered by polyethene sheathing including cap etc. complete.And As Directed by Engineer Incharge

364

84575

232.35

... More
Providing and fixing in position anticorrosive TMT FE 500 tie bars of 12 mm dia. 70 cms. long and at 30.00 cm. C/C and wherever directed including handling, straightening necessary cutting, handling, straightening, supported by assembly of TMT FE 500, chairs with proper alignment etc. complete.And As Directed by Engineer Incharge

9375

595312

63.5

... More
Dismantling Stone Masonry as per Technical Specification MORD 2014 Clause 202. Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification MORD 2014 Clause 202. Rubble Stone Masonry in Cement Mortar And As Directed by Engineer Incharge

65.63

32102

489.15

... More
Removing all types of Hume pipes and stacking within a lead of 1000 m including Earthwork and Dismantling of Masonry Works as per Technical Specification MORD 2014 Clause 202. Upto 600 mm dia Hume pipe And As Directed by Engineer Incharge

52.5

30875

588.1

... More
Earthwork in excavation for structures as per drawing and technical specifications Ministry Of Rural Development 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 meter, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary soil And As Directed by Engineer Incharge

404.6

271183

670.25

... More
Earthwork in excavation for structures as per drawing and technical specifications Ministry Of Rural Development 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 meter, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary rock (not requiring blasting) Upto 3 meter depth And As Directed by Engineer Incharge

269.08

225448

837.85

... More
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Hard rock (blasting prohibited) Upto 3 meter depth And As Directed by Engineer Incharge

39.2

37714

962.1

... More
Filling in foundation trenches as per drawing and technical specification Clause 305.3.9 Rubble soling with Rubble And As Directed by Engineer Incharge

27.42

59188

2158.6

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 Plane cement concreate grade M 10 Nominal mix 1:3:6 And As Directed by Engineer Incharge

65.84

422146

6411.7

... More
Providing concrete for plain/reinforced concrete in sub structure complete as per drawings and technical specifications Ministry Of Rural Development 2014 Clause 802, 803, 804, 805, 806, 807, 1202 & 1203, 1204 Plain cement concreate grade M 15 Nominal mix (1:2.5:5) And As Directed by Engineer Incharge

511.53

3402441

6651.5

... More
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. B. 1000 milimeter Non pressure 3 Class As per Technical Specification Ministry Of Rural Development 2014 Cluase No. 1100 And As Directed by Engineer Incharge

145

1094713

7549.75

... More
Providing and laying reinforced cement concrete pipe Non pressure2 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. D. 600 milimeter Non pressure 2 Class As per Technical Specification Ministry Of Rural Development 2014 Cluase No. 1100 And As Directed by Engineer Incharge

177.5

485107

2733

... More
Providing and laying cement concrete wearing course M30 grade Excluding reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3 And As Directed by Engineer Incharge

21.15

301940

14276.15

... More
Providing weepholes in brick masonry / stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 milimeter dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7 A.C. pipe 100 milimeter Dia And As Directed by Engineer Incharge

100

30340

303.4

... More
Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1303 And As Directed by Engineer Incharge

120.76

269029

2227.8

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per Indian Road Congress:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Ministry Of Rural Development 2014 Clause 1703 Ordinary Kilometer Stone (Precast) And As Directed by Engineer Incharge

3

8921

2973.9

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per Indian Road Congress:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Ministry Of Rural Development 2014 Clause 1703 200 meter stone (precast) And As Directed by Engineer Incharge

12

10008

834.05

... More
Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per Indian Road Congress:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704. And As Directed by Engineer Incharge

265

222706

840.4

... More
MMGSY / PMGSY Citizen' s information Board- Providing and fixing of typical PMGSY Retro Reflective information board as per as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circular and drawing. Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottom duly rivetted with MS angles of 35 x 35 x 5 mm thick M.S angle shall be welded by two vertical M.S angle of 5 mm thick to 75 mm x 75 mm of 12 SWG square tubes / 75mm Dia Pipe posts duly embedded in cement concrete M-20 grade blocks of 600mm x 600mm x 75mm, below ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circular no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4 and as directed by Engineer-In-charge. . A warranty for 5 / 7 years for the Retro reflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor. And As Directed by Engineer Incharge

2

57370

28685

... More
Providing and fixing of typical Mukhya Mantri Gram Sadak Yojana informatory sign board with Logo as per Ministry Of Rural Development specifications and drawing. Three Mild steel Plates of 1.6 mm thick, top and middle plate duly welded with Mild steel flat iron 25Millimeter x 5meter size on back on edges. The lower plate will be welded with Mild steel angle iron frame of 25 Millimeter x 25 Millimeter x 5 Millimeter. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75Millimeter x 75 Millimeter of 12 Steel wire Gause sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450Millimeter x 450Millimeter x 600Millimeter, 600Millimeter below ground level. The top most diamond plate will be welded to middle plate by 47Millimeter x 47Millimeter of 12 Steel wire Gauge steel plate tube. All Mild steel will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 'Logo' of Mukhya Mantri Gram Sadak Yojana Project And As Directed by Engineer Incharge

2

36697

18348.7

... More
Providing and erecting direction and place identification of semi reflective sign boards as per IRC-67 made of 2 mm thick M.S. Sheet duly stove enameled paint white colour in front and grey colour on back with reflective border of 70 mm width and required message, letters, figures with reflective tape of engineering grade as per MORD specifications of required shade and colour. Supported and welded on two nos. 47 mm x 47 mm of 12 SWG square tube of 3050 mm height duly strengthened by 25 mm x 5 mm MS flat iron on edges on back firmly fixed to the ground by means of properly designed foundations with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701 And As Directed by Engineer Incharge

6

24657

4109.5

... More
Providing and fixing Cautionary/Warning sign boards in Equilateral Triangle size of mm made out of mm aluminum sheet bonded with white retro reflective sheeting of Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3 Supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with grey stove enamel paint and supported on one no. of M. S. angle iron post of size 65 mm X 65 mm X 6 mm, 3.45 m long, duly painted with with flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in M25 grade concrete block of size 60cm X 60cm X 75cm including transportation etc; complete. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier and As Directed by Engineer Incharge

28

107212

3829

... More
Providing and fixing of retro- reflectorised informatory sign board rectangular/Square in shape having area less than 0.9 One Square Meterr made out of mm aluminum sheet bonded with white retro reflective sheeting of Class ( Type IV High intensity micro- prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3, supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with two coats of grey stove enamel paint and supported on one no. mild steel angle iron post 75 mm x 75 mm x 6 mm, 3.5 mt long firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing The angle iron post shall be duly painted with one coat of epoxy primer and two coats of epoxy finish paints having alternate black and white bands of 25 cm width including GI fixures and transportation etc.complete.The nut bolts of board with angle iron post/supporting structure after fixing at site has to be electrically welded. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) sheeting shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier. 600 x 450 milimeter Rectangular And As Directed by Engineer Incharge

2.16

20880

9667

... More
Providing and fixing Mandatory/Regulatory sign boards in circular shape of mm dia made out of mm aluminum sheet bonded with white retro reflective sheeting of Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3 Supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with grey stove enamel paint and supported on one no. of M. S. angle iron post of size 65 mm X 65 mm X 6 mm, 3.45 m long, duly painted with with flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in M25 grade concrete block of size 60cm X 60cm X 75cm including transportation etc; complete. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier. 600mm circular And As Directed by Engineer Incharge

26

117416

4516

... More
Providing and Laying hot applied thermoplastic road marking strip on Bituminous Surface of specified shade/ colour of 2.5 mm thick including 1.5 Refractive index reflectorizing glass beads @ 250gm/sqm .Thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC 35:2015. Initial Dry reflectivity RL shall be 250 mcd/sqm/lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/sqm/ lux and Qd of 100 mcd/sqm/ lux measured at the end of 2 years by means of a Standard Reflectometer of Zehntner, Easylux, Delta make capable of measuring RL & QD both according to IRC 35:2015 clause 15.5. The finished surface to be level, uniform, and free from streaks and holes complete as per direction of Engineer-in-charge and in accordance with applicable specifications.(Refer MORTH Clause 803 for technical Specification and Performance for IRC 35:2015) And As Directed by Engineer Incharge

562

374292

666

... More
Road Delineators: Supplying and installation of delineators (Roadway Indicators, Hazard markers, Object markers) 80 to 100 cm high above ground level, painted black and white in 15cm wide strips, fitted with 80x100mm rectangular or 75mm dia. Circular reflectorised panels at the top, buried or pressed into the ground and confirming to I.R.C. 79 and the drawings And As Directed by Engineer Incharge

36

29592

822

... More
Providing and fixing in position Pipe Railing consisting of IS Rolled steel joist posts designation IS MB 100 (100x75) at 2.5 m interval and three rows of 50 mm dia steel pipes (light) including fixing in position on bridge deck complete as per drawing and technical specifications Clause 1208.2 And As Directed by Engineer Incharge

25

52247

2089.9

... More
Painting two coats including prime coat with epoxy paint of approved brand on concrete/steel surfaces after through cleaning of surface to give an even shade as per drawing and Technical Specification Clause 1701 And As Directed by Engineer Incharge

1.08

178

165.45

... More
White washing two coats on parapet walls and white washing and geru lime painting to tree trunks including preparation of surface by cleaning scraping etc. complete And As Directed by Engineer Incharge

18

468

26

... More
A,W : Metal Beam Crash Barrier (Providing and erecting a "W "metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip cess, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810) And As Directed by Engineer Incharge

90

442080

4912

... More
Providing and Laying of 2 or more sets (6Nos. each set) Dual Ribs Pattern Rumble Markings on roads with vehicular speeds of more than 50 Km/hr laid as per the spacing recommended for each set under Table11.1 and Fig.11.2 of IRC35:2015 using Plastirib 2K, or equivalent 2 component cold plastic profiled material. Each Dual Rib pattern rumble marking shall have width of 500mm. Each dual rib pattern rumble marking shall have 2 ribs each of Width of 100mm and height 20mm. Gap between two ribs shall be 300mm. Each rumble marking shall be made complete with drop on Soild Plus reflective glass beads @ 300 gm / One Square Metre spread throughout the surface of marking. The finished surface to be levelled,uniform and free from streaks and holes,including surface cleaning and cost of all materials etc. complete And As Directed by Engineer Incharge. A) Improvement of Road from Atpadi to Pandhrewadi (Ranmala) Road Ch 0/000 to Ch 6/020, Taluka -Atpadi, District:-Sangli-(65877378.14), B) Improvement of Road from Shetphale to Chavarwasti(Ranmala) Road Ch 0/000 to 4/480, Taluka -Atpadi, District:-Sangli-(44343518.39), C) Improvement of Road from Gomewadi to Hivtad Shukracharya Road Ch 0/000 to 3/420, Taluka -Atpadi, District:-Sangli- (39748088.03), D) Improvement Of Road From Ghanwad To (Bhagyanagar ) Bhakuchiwadi Road Ch 0/000 to 3/910, Taluka -Khanapur , District:-Sangli - (60391968.95), E) Improvement of Road from Nagewadi To Godachiwadi ( Kanharwadi Dist. Border) Road Ch 0/000 To 4/100, Taluka -Khanapur, District:-Sangli - (36507982.61), F) Improvement of Road from SH 143 Vibhutwadi to Gulewadi Ch 0/000 to 3/630, Taluka -Atpadi, District:-Sangli - (35124958.04), G) Improvement of Road from Hivare to Jadhvwasti Ch 0/000 to 2/370, Taluka -Khanapur, District:-Sangli-(26429355.61), H) Improvement of Road from Kamlapur to Mahalaxmi Mandir Ch 0/000 to 4/000, Taluka -Khanapur, District:-Sangli- (47312860.80), I) Improvement of Road from Vita to Chinchani (M) (Khairatimala) Road (Part Chinchani (m) to Khairatimala Road) Ch 1/200 to 4/000, Taluka -Khanapur, District:-Sangli- (35356927.78), I) Improvement of Road from Hingangade to Salunkhewasti Ch 0/000 to 2/000 Taluka -Khanapur, District:-Sangli, Taluka -Khanapur-(24613395.64), K) Improvement of Road from Hatnoor to Pirdeo road Ch 0/000 to 2/780, Taluka -Tasgaon, District:-Sangli-(33400281.25),

6

25998

4333



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.