Rural Development Department Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Rural Development Department - RDD Tender

Works
Civil And Construction
Road Construction
Eprocure
Opening Date5 Jun 2023
Closing Date13 Jun 2023
Tender Amount₹ 13,17,69,942 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Cutting of trees, including cutting of trunks, branches and removal of stumps & roots, refilling, compaction of backfilling and stacking of serviceable material by manual means with all lifts as per Technical Specification Clause 201. Girth above 300 mm to 600 mm

2

938

469.49

... More
Cutting of trees, including cutting of trunks, branches and removal of stumps & roots, refilling, compaction of backfilling and stacking of serviceable material by manual means with all lifts as per Technical Specification Clause 201. Girth above 600 mm to 900 mm

3

2249

749.72

... More
Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and croun-sections, and transporting to the embankment location with a lift upto 1.5 m and lead above 1000 m as per Technical Specification MORD 2014 Clause 302.3

141939.06

8741884

61.59

... More
Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, transporting to embankment site with a lift upto 1.5 m and lead above 1000 m, trimming bottom and side slopes in accordance with requirements of lines, grades and croun-sections as per Technical Specification MORD 2014 Clause 302.3.5

9022.85

851080

94.33

... More
Excavation for roadway in hard rock (requiring blasting) by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and croun-sections, loading and disposal of cut rock with a lift upto 1.5 m and with all leads as per Technical Specification MORD 2014 Clause 302.3.5

9022.85

951026

105.4

... More
Excavation in Hard Rock (blasting Prohibited) -Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal with a lift upto 1.5 metre and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification Clause 302.3.5

18045.7

7452386

412.97

... More
Excavation for roadway in hard rock with controlled blasting by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross-sections, loading and disposal of cut rock with a lift upto 1.5 m and leads upto 1000 m as per Technical Specification Clause 302.3.5

3609.14

628975

174.27

... More
Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5

44933.7

3566657

79.38

... More
Construction of Granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. For Grading I material by mix in Place Method

4709.91

9628875

2044.39

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, Stone screening biding material to fill-up the interstices of coarse aggregate, watering and compacting to the required density WBM Grading 2 as per Technical Specification Clause 405. For - By Mechanical Means

1875.09

4527680

2414.65

... More
Modified Penetration Macadam- Construction of penetration macadam over prepared base by providing a layer of compacted crushed coarse aggregate using chips spreader with alternate applications of bituminous binder and key aggregates and rolling with a three wheel 80-100 kN static roller to achieve the desired degree of compaction as per Technical Specification Clause 506.(50 mm thick Bitumen (S-65) Material As per MORD specification no. 506)

24988.25

5930306

237.32

... More
20mm thick Open-Graded Premix Carpet using S 65 (penetration grade/modified bitumen) Binder Bitumen(S-65) 60/70- (VG 30)-Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades. to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508 . Case - II By Mechanical Means, Bitumen(S-65) - (VG 30)

24988.25

4126244

165.13

... More
Tack Coat -Providing and applying tack coat with Bitumen emulsion (Rapid Setting-1) using emulsion distributor at the rate of 0.20 to 0.25 kilogram per square meter on the prepared bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503

24988.25

353854

14.16

... More
Seal Coat-Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A , Type B (by Paver finisher) and Type C as per Technical Specification Clause 510

24988.25

2076700

83.11

... More
Road Marking with Hot Applied Thermoplastic Compound with Reflectorizing Glass Beads on Bituminous Surface- Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorizing glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.complete.

260

192207

739.26

... More
Road Delineators: Supplying and installation of delineators (Roadway Indicators, Hazard markers, Object markers) 80 to 100 cm high above ground level, painted black and white in 15 cm wide strips, fitted with 80x100mm rectangular or 75mm dia. Circular reflectorised panels at the top, buried or pressed into the ground and confirming to I.R.C. 79 and the drawings

250

228105

912.42

... More
Retroreflective tape (Engg Gr.)

70

81658

1166.55

... More
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 1.5 mm thick supported on GI pipe 50 mm dia firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 1701 a. 600 mm equilateral triangular

14

36226

2587.64

... More
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 1.5 mm thick supported on GI pipe 50 mm dia firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 1701 b. 600 mm circular

8

20701

2587.64

... More
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 1.5 mm thick supported on GI pipe 50 mm dia firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 1701 c. 600 x 450 mm Rectangular

5

12938

2587.64

... More
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 1.5 mm thick supported on GI pipe 50 mm dia firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 1701 d. 600 x 600 mm Square

5

12938

2587.64

... More
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 1.5 mm thick supported on GI pipe 50 mm dia firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 1701 e. 900 x 600 mm Rectangular

5

12938

2587.64

... More
Providing and fixing Retro Reflective MMGSY/PMGSY LOGO informatory sign board with Logo as per section 1700 of MORD specification sand latest PMGSY Signage Manual/Circuler and drawing. The board will be a composite unit consisting of Two Plates of ACP (Aluminum Composite Panel), material specifications as per clause 17001.3. The top most plate will be of 3mm ACP in diamond shape of 600x600 mm size, rivete dwith MS angle ironframe of 25mmx25mmx5mm size on back on edges. The Lower plate will be of 4mm ACP of 1100x300mm size riveted with MS angle ironframe of 25mmx25mmx5mm size on back on edges. Riveting of all the sheets over angle and flat ironframe will be done neatly to have plain surface on one side. The angle ironframe of Both the plates will be welded to a 75mmx75mmx12 swg Mild steel post at/Tube Centre and this post will be embeded in cement concrete M15 grade block of 450x450x600mm below ground level. The height of the bottom of the lower plate will be 1200 mm from normal ground level. The spacing between the diamond shaped plate and Lower Plate is kept 150mm. MMGSY/PMGSY logo, letters and numeral sonthe ACP should be made up of Retro Reflective sheeting of Class-A/Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013 (11) /3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo MMGSY Logo Project description on ClassA or ClassB type retroreflective sheeting using modern technology printing plat form. The printer shall be approved by the retroreflective sheeting manufacturer and printe dsign shall conform to retroreflective values as laid down in IRC67-2012. The in k sused for printing shall be ecofriendly with VOC emissions complying to UL2801 standards and specifications for the different kinds of plat forms. The printe dsign shall be laminated by UV protected laminate and shall carry awarranty of 5 years & 7 years for ClassA and ClassB sheeting respectively for traffic colors.” All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY signage manual Fig.1 (A) and Fig.1(B) and as directed by Engineerin-charge. A warranty for 5/7 years for the Retroreflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor.(SOR ITEM NO.10.16 ) A) Retro Reflective sheeting class-A

2

32471

16235.7

... More
MMGSY/PMGSY Citizen's information Board-Providing and fixing of typical PMGSY Retro Reflective information board as per as per section1700 of MORD specification sand latest PMGSY Sign age Manual/Circuler and drawing.Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottom duly rivetted with MS angles of 35x35x5mm thic kM. Sangle shall be welded by two vertical M.S angle of 5mm thick to 75mmx75mm of 12 SWG square tubes/75mm Dia Pipe posts duly embedded in cement concrete M-20 grade blocks of 600mmx600mmx75mm, below ground level . MMGSY/PMGSY logo, letter sand numer also n the ACP should be made up of Retro Reflective sheeting of Class-A/Class-B grade as per the latest MORD section1700 specifications (Refer Circuler no. NRRDA-P 013 (11) /3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo /MMGSY Logo/Project descriptionon ClassA or ClassB type retroreflective sheeting using modern technology printing platform. The printer shall be approved by the retroreflective sheeting manufacturer and printe dsign shall conform to retroreflective values as laid down in IRC67-2012. The inks used for printing shall bee co friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of plat forms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All sections of framed post sand steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4 and as directed

2

32471

16235.7

... More
Reinforced cement concrete M15 grade 5 th kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014 Clause 1703 5th Kilometer Stone (Precast)

1

4735

4735.57

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014 Clause 1703 Ordinary Kilometer Stone (Precast)

6

16685

2780.88

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014 Clause 1703 200 m stone (precast)

32

18450

576.58

... More
(Village Name Board) Providing and Fixing of Retro Reflectorised direction & place identification sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4 mmt hick ACP sheet supported with Back support frame of 35x35x5 mm mild steel angle with are as not exceeding 0.9 sqm. Supported in mild steel angle iron post 75x75x6mm-3.5mt rheight, firmly fixed to the ground by means of properly designed foundation of M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level complete (as per MoRT & H specification No.801) (for area Less than 0.9 sqm). 7 Both border & background shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product offered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. The reshall be as tamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting.

3.6

13676

3799

... More
Supplying & Fixing of Molded Shank Raised Pavement Markers / Cat's Eye made of polycarbonate and ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face and shall support a load of 16000 kg tested in accordance to ASTM D 4280 Type H and complying to Specifications of Category A of MORTH Circular No RW/NH/33023/10-97 DO III Dt 11.06. 1997. The height, width and length shall not exceed 50 mm, 100 mm and 102 +/- 2 mm and with minimum reflective area of 13 Sqcm on each side and the slope to the base shall be 35 +/- 5 degree. The strength of detachment of the integrated cylindrical shanks, (of diameter not less than 19 +/- 2 mm and height not less than 30+/- 2 mm) from the body is to be a minimum value of 500 Kg. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturer's recommendation and complete as directed by the engineer.The contractor shall submit a two year warranty for satisfactory field performance including stipulated retro-reflectance of the reflecting panel, to the Engineer.

500

203130

406.26

... More
Boundary Pillar / Guard Stone-Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704

630

414559

658.03

... More
Providing laterite stone machinery in civil mortal 1:6 per foundation and plinth including streaking joints on the unexpose faces and watering complete letterhead stone 6 sides cut and thickness of motor joints be 12 mm Max

7.3

52742

7224.99

... More
Hazard Board- Providing and Fixing of Retro Relectorised 300 x 900 milimeter Hazard marked boards made out of aluminium sheet bonded with white retro reflective sheeting (Type IV High intensity micro - prismatic grade sheeting - HIP) having pressure sensitive / heat activated adhesive retroflective specified back ground, border and back side retoreflective symbols, letters, numerals, arrow as per Indian Road Congress 67-2012 Table No.8.3, supported with back support frame 25 milimeter x 25 milimeter x 3 milimeter, duly painted on back side with two coats of grey stove enamel paint and supported on one no mild steel steel angle iron post 75 milimeter x 75 milimeter x 6 milimeter, 3.5 meter long firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 centimeter x 45 centimeter x 60 centimeter, 60 centimeter below ground level as per approved drawing. the angle iron post shall be duly painted with one coat of epoxy primer and two coats of epoxy finish paints having laternate black and white bands of 25 centimeter width including GI fixtures and transportation etc complete. The nut bolts of board with angle iron post / supporting structure after fixing at site has to be electrically welded, Class B (Type IV High intensity micro-prismatic grade sheeting-HIP) sheeting shall have 7 years written written warranty from the manufacturer and authorised distributor / convertor issued for field performance includingthe screen printed areas ang cut-out durable transperent overlay film and this warranty certificate in original should besubmitted to the Engineer in charge by the contractor / supplier.

4

14178

3544.65

... More
Metal Beam Crash Barrier -- Type - A, W : Metal Beam Crash Barrier (Providing and erecting a W "metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810)

380

2071881

5452.32

... More
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202.

0.51

421

825.52

... More
Removing all types of Hume pipes and stackig within a lead of 1000 m including Earthwork and Dismantling of Masonry work as per Technical Specification clause 202- Above 600 to 900mm dia. Hume pipe

82.5

42390

513.82

... More
Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary soil By Mechanical means

1017.33

595710

585.56

... More
Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary rock (not requiring blasting) Upto 3 m depth

327.21

204232

624.16

... More
Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Hard rock (requiring blasting) Upto 3 m depth including 1.5 m depth in hard rock

416.67

427770

1026.64

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802,803, 1202 & 1203 P.C.C grade M 10 Nominal mix (1:3:6)

341.06

2043398

5991.38

... More
Plain/reinforced cement concrete in sub structure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 - P.C.C grade M 15 Nominal mix (1:2.5:5)

1776.28

11358991

6394.8

... More
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. B. 1000 mm NP3 Class As per Technical Specification MORD 2014 Cluase No. 1100

217.5

1691318

7776.18

... More
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. 600 NP3 Class

60

319147

5319.12

... More
Providing and laying reinforced cement concrete pipe NP2 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. D)600 mm dia NP2

75

227522

3033.63

... More
Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered/concrete surfaces as per drawing and Technical Specification Clause 1701

318.64

50367

158.07

... More
Providing weepholes in brick masonry / stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification MORD 2014 Clauses 614, 709, 1204.3.7 A.C. pipe 100 mm Dia

420.5

83846

199.4

... More
Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1302

197.8

328786

1662.22

... More
Providing and laying filter material underneath pitching in slopes complete as per drawing and technical specifications Clause 1302

129

349094

2706.16

... More
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202.

20.07

4761

237.23

... More
Backfilling behind abutment, wing wall and return wall with Granular Material complete as per drawings & technical specification Clause 1204.3.8

164.7

270677

1643.46

... More
Supplying, fitting, and placing TMT bar reinforcement in substructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202

8.57

586691

68466.71

... More
Printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade as per drawings and Technical Specification Clause 1701

775

1236

1.6

... More
2.00 Upgradation & Maintanance of Asaniye varchiwadi Gharpi Road ,Taluka-- Sawantwadi,District-Sindhudurg.

-

-

-

... More
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Mord 2014 Clause 201. (A) In area of Non-thorny jungle

0.48

19142

39879.53

... More
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Mord 2014 Clause 201. (B) In area of thorny jungle

0.72

23322

32392.7

... More
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lead lifts m as per Technical Specification Clause 202.Rubble Stone Masonry in Cement Mortar, as directed by Engineer in Charge.

23.62

20260

857.78

... More
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lead lifts m as per Technical Specification Clause 202.Cement Concrete , as directed by Engineer in Charge.

0.6

495

825.52

... More
Scarifying the existing Bituminous surface to a depth of 150 mm and disposal of scarified material with a lift up to 3 m and lead upto 1000 m as per technical specificationa Clause 301.4

8697

121236

13.94

... More
Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and croun-sections, and transporting to the embankment location with a lift upto 1.5 m and lead above 1000 m as per Technical Specification MORD 2014 Clause 302.3

28495.22

1755020

61.59

... More
Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, transporting to embankment site with a lift upto 1.5 m and lead above 1000 m, trimming bottom and side slopes in accordance with requirements of lines, grades and croun-sections as per Technical Specification MORD 2014 Clause 302.3.5

1636.19

154341

94.33

... More
Excavation for roadway in hard rock (requiring blasting) by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and croun-sections, loading and disposal of cut rock with a lift upto 1.5 m and with all leads as per Technical Specification MORD 2014 Clause 302.3.5

818.1

86227

105.4

... More
Excavation in Hard Rock (blasting Prohibited) -Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal with a lift upto 1.5 metre and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification Clause 302.3.5

1636.19

675697

412.97

... More
Excavation for roadway in hard rock with controlled blasting by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross-sections, loading and disposal of cut rock with a lift upto 1.5 m and leads upto 1000 m as per Technical Specification Clause 302.3.5

818.1

142570

174.27

... More
Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5

14269.15

1132685

79.38

... More
Construction of Granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. For Grading I material by mix in Place Method

661.37

1352098

2044.39

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density WBM Grading 2 as per Technical Specification Clause 405. For - By Mechanical Means

951.89

2263603

2378.01

... More
Modified Penetration Macadam- Construction of penetration macadam over prepared base by providing a layer of compacted crushed coarse aggregate using chips spreader with alternate applications of bituminous binder and key aggregates and rolling with a three wheel 80-100 kN static roller to achieve the desired degree of compaction as per Technical Specification Clause 506.(50 mm thick Bitumen (S-65) Material As per MORD specification no. 506)

11583

2742159

236.74

... More
20mm thick Open-Graded Premix Carpet using S 65 (penetration grade/modified bitumen) Binder Bitumen(S-65) 60/70- (VG 30)-Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades. to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508 . Case - II By Mechanical Means, Bitumen(S-65) - (VG 30)

11583

1906330

164.58

... More
Tack Coat -Providing and applying tack coat with Bitumen emulsion (Rapid Setting-1) using emulsion distributor at the rate of 0.20 to 0.25 kilogram per square meter on the prepared bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503

11583

163204

14.09

... More
Seal Coat-Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A , Type B (by Paver finisher) and Type C as per Technical Specification Clause 510

11583

958840

82.78

... More
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.

267.82

156824

585.56

... More
Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary soil By Mechanical means

18.85

9733

516.36

... More
Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Hard rock (requiring blasting) Upto 3 m depth including 1.5 m depth in hard rock

55.14

50664

918.84

... More
Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Hard rock (blasting Provided) Upto 3 m depth including 1.5 m depth in hard rock

53.3

44358

832.24

... More
Removing all types of Hume pipes and stacking within a lead of 1000 m including Earthwork and Dismantling of Masonry Works as per Technical Specification Clause 202. upto 600 mm Hume pipe

12

4560

380.04

... More
Removing all types of Hume pipes and stackig within a lead of 1000 m including Earthwork and Dismantling of Masonry work as per Technical Specification clause 202- Above 600 to 900mm dia. Hume pipe

15

7707

513.82

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802,803, 1202 & 1203 P.C.C grade M 10 Nominal mix (1:3:6)

71.4

425698

5962.16

... More
Plain/reinforced cement concrete in sub structure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 - P.C.C grade M 15 Nominal mix (1:2.5:5)

650.48

4140688

6365.59

... More
Providing and laying reinforced cement concrete pipe NP2 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. D)600 mm dia

40

120252

3006.3

... More
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. B. 1000 mm NP3 Class As per Technical Specification MORD 2014 Cluase No. 1100

37.5

291606

7776.18

... More
Supplying, fitting and placing TMT bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202

1.48

101330

68466.71

... More
Supplying, fitting, and placing TMT bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202

1.82

128381

70539.15

... More
Providing weepholes in brick masonry / stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification MORD 2014 Clauses 614, 709, 1204.3.7 A.C. pipe 100 mm Dia

146.25

29162

199.4

... More
Backfilling behind abutment, wing wall and return wall with Granular Material complete as per drawings & technical specification Clause 1204.3.8

175.5

288427

1643.46

... More
Printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade as per drawings and Technical Specification Clause 1701

150

241

1.61

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 Ordinary Kilometer Stone (precast). as directed by Engineer in Charge.

4

11123

2780.88

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 200 meter Stone (precast). as directed by Engineer in Charge.

12

6918

576.58

... More
Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704, as directed by Engineer in Charge.

300

197409

658.03

... More
Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered/concrete surfaces as per drawing and Technical Specification Clause 1701

55.71

8806

158.07

... More
Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 as directed by Engineer in Charge.

2

32471

16235.7

... More
Sign Board of MMGSY / PMGSY Project Information : Providing and fixing of typical retro reflective MMGSY / PMGSY Project informatory sign board with Logo as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing. The board will be a composite unit consisting of Three Plates ACP (Aluminum Composite Panel), material specificaitons as per clause 17001.3. The top most plate will be of 3mm ACP in diamond shape of 600x600mm size, riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. The middle 4mm ACP plate of will be 1200x150mm size riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. The main 4mm ACP lower most plate will be 1500mmx600mm size, riveted with MS angle iron frame of 25mmx25mmx5mm size. Riveting of all the sheets over angle and flat iron frame will be done neatly to have plain surface on one side. The angle iron frame of lower most plate and flat iron frame of the middle plate will be welded to two nos. 75mm x75mm x 12 swg sheet tubes posts placed at 1125mm apart centre to centre. the top of the middle plate will be flushed with the top of 75mm dia medium steel tube posts and these posts will be embeded in cement concrete M15 grade block of 450x450x600mm below ground level. The height of the bottom of the lower plate will be 1200mm from normal ground level and the bottom of the middle plate will be 100mm above the top level of the lower most plate. the diamond shaped plate mounted over flat angle iron frame will be connected to middle plate by square steel section of 47mmx47mm, thickness 12SWG having a spacing of 100mm between the diamond shaped plate and middle plate and this square section will be riveted to the bottom point of the diamond shaped plate. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no.

3

48707

16235.7

... More
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 1.5 mm thick supported on GI pipe 50 mm dia firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 1701 600 mm x 600 mm Square

4

10350

2587.64

... More
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 1.5 mm thick supported on GI pipe 50 mm dia firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 1701 600 mm equilateral triangular

30

77629

2587.64

... More
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 1.5 mm thick supported on GI pipe 50 mm dia firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 1701 900 x 600 milimeter reclangular

6

15525

2587.64

... More
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 1.5 mm thick supported on GI pipe 50 mm dia firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 1701 600 x 450 mm Rectangular

4

10350

2587.64

... More
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 1.5 mm thick supported on GI pipe 50 mm dia firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 1701 600 mm circular

4

10350

2587.64

... More
Providing and Fixing of Retro Reflectorised direction & place identification sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type IV standards of ASTM D4956-09 specifications, fixed over 4 mm thick ACP sheet supported with Back support frame of 35x35x5mm mild steel angle with areas not exceeding 0.9 sqm. Supported in mild steel angle iron post 75x75x6mm - 3.5 mtr height ,firmly fixed to the grounf by means of properly designed foundation of M 20 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level complete (as per MoRT&H specification No.801) (for area Less than 0.9 sqm). 7Both border & background shall be retro reflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor(Bottom of the board shall be at least 2.6 mtr. above ground level) Specification: IRC 67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective

3.6

13676

3799

... More
Metal Beam Crash Barrier -- Type - A, W : Metal Beam Crash Barrier (Providing and erecting a W "metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810)

100

545232

5452.32

... More
Shifting of Water Supply Lines ( Providing,layingandfixingP.V.C.pipeof50mmdia.withfittingssuchasbends,tees,reducers,clamps,etc.includingnecessaryexcavation,trenchfillingetc.complete.Includingremovingexistingpipelineifnecessaryandconveyingandstacking the same in PWD chowky or as directed etc. complete.)

163.79

76723

468.42

... More
Providing laterite stone machinery in civil mortal 1:6 per foundation and plinth including streaking joints on the unexpose faces and watering complete letterhead stone 6 sides cut and thickness of motor joints be 12 mm Max

36.5

263949

7231.5

... More
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. 600 NP3 Class

7.5

39534

5271.2

... More
Providing and Constructing gabion structure 1 Meter high or required section made up of soft mechanically woven hexagonal shaped G.I. wire confirming to IS 16014:2012 having zinc plus PVC coating of overall diameter of 3.7 mm and tying lacing wire of 3.2 mm with edge wire confirming to overall diameter 4.4 mm edges being mechanically selvedge including placing in position, fitting neatly with trap stone rubble (15 to 23 cm) all loose ends to be securely tied (Excluding transportation) etc. complete. ( In Dry condition and for under water installation extra cost to be considered)as directed by Engineer in Charge.

300

792198

2640.66

... More
3.00 Upgradation & Maintanance of Amboli satlchiwaadi Gele Gavthan Road ,Taluka-- SAWANTWADI,District-Sindhudurg

-

-

-

... More
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Mord 2014 Clause 201. (A) In area of Non-thorny jungle

0.8

31903

39879.53

... More
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Mord 2014 Clause 201. (B) In area of thorny jungle

1.2

38871

32392.7

... More
Loosening, Levelling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Tables 300.1 and 300.2 for embankment construction as per Technical Specification Clause 301.4.1.

216.38

6625

30.62

... More
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lead lifts m as per Technical Specification Clause 202.Rubble Stone Masonry in Cement Mortar, as directed by Engineer in Charge.

411.95

353362

857.78

... More
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lead lifts m as per Technical Specification Clause 202.Cement Concrete , as directed by Engineer in Charge.

14.48

11953

825.52

... More
Scarifying the existing Bituminous surface to a depth of 150 mm and disposal of scarified material with a lift up to 3 m and lead upto 1000 m as per technical specificationa Clause 301.4

8679

120985

13.94

... More
Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and croun-sections, and transporting to the embankment location with a lift upto 1.5 m and lead above 1000 m as per Technical Specification MORD 2014 Clause 302.3

9606.11

591640

61.59

... More
Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, transporting to embankment site with a lift upto 1.5 m and lead above 1000 m, trimming bottom and side slopes in accordance with requirements of lines, grades and croun-sections as per Technical Specification MORD 2014 Clause 302.3.5

1371.19

129344

94.33

... More
Excavation for roadway in hard rock (requiring blasting) by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and croun-sections, loading and disposal of cut rock with a lift upto 1.5 m and with all leads as per Technical Specification MORD 2014 Clause 302.3.5

274.24

28904

105.4

... More
Excavation in Hard Rock (blasting Prohibited) -Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal with a lift upto 1.5 metre and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification Clause 302.3.5

1371.19

566260

412.97

... More
Excavation for roadway in hard rock with controlled blasting by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross-sections, loading and disposal of cut rock with a lift upto 1.5 m and leads upto 1000 m as per Technical Specification Clause 302.3.5

1371.19

238957

174.27

... More
Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5

8361.57

663741

79.38

... More
Construction of Granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. For Grading I material by mix in Place Method

2122.95

4340137

2044.39

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density WBM Grading 2 as per Technical Specification Clause 405. For - By Mechanical Means

2878

6132240

2130.73

... More
Modified Penetration Macadam- Construction of penetration macadam over prepared base by providing a layer of compacted crushed coarse aggregate using chips spreader with alternate applications of bituminous binder and key aggregates and rolling with a three wheel 80-100 kN static roller to achieve the desired degree of compaction as per Technical Specification Clause 506.(50 mm thick Bitumen (S-65) Material As per MORD specification no. 506)

27597

6534969

236.8

... More
20mm thick Open-Graded Premix Carpet using S 65 (penetration grade/modified bitumen) Binder Bitumen(S-65) 60/70- (VG 30)-Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades. to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508 . Case - II By Mechanical Means, Bitumen(S-65) - (VG 30)

27597

4546053

164.73

... More
Tack Coat -Providing and applying tack coat with Bitumen emulsion (Rapid Setting-1) using emulsion distributor at the rate of 0.20 to 0.25 kilogram per square meter on the prepared bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503

27597

388841

14.09

... More
Seal Coat-Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A , Type B (by Paver finisher) and Type C as per Technical Specification Clause 510

27597

2285307

82.81

... More
Construction of un-reinforced, dowel jointed at expansion and construction joint only, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel,edges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, admixtures as approved, curing of concrete slabs for 14-days, using curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification Clause 1501(excluding dowel bars and Polythene sheet)

110

896541

8150.38

... More
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.

1162.88

680936

585.56

... More
Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary soil By Mechanical means

587.25

303232

516.36

... More
Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Hard rock (requiring blasting) Upto 3 m depth including 1.5 m depth in hard rock

721.26

662722

918.84

... More
Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Hard rock (blasting Provided) Upto 3 m depth including 1.5 m depth in hard rock

95.95

79853

832.24

... More
Removing all types of Hume pipes and stackig within a lead of 1000 m including Earthwork and Dismantling of Masonry work as per Technical Specification clause 202- Above 600 to 900mm dia. Hume pipe

232.5

119463

513.82

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802,803, 1202 & 1203 P.C.C grade M 10 Nominal mix (1:3:6)

77.52

460911

5945.71

... More
Plain/reinforced cement concrete in sub structure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 - P.C.C grade M 15 Nominal mix (1:2.5:5)

830.13

5269250

6347.5

... More
Providing and laying reinforced cement concrete pipe NP2 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. 600 mm dia

50

151681

3033.63

... More
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. B. 1000 mm NP3 Class As per Technical Specification MORD 2014 Cluase No. 1100

135

1049784

7776.18

... More
Providing weepholes in brick masonry / stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification MORD 2014 Clauses 614, 709, 1204.3.7 A.C. pipe 100 mm Dia

123.75

24675

199.4

... More
Backfilling behind abutment, wing wall and return wall with Granular Material complete as per drawings & technical specification Clause 1204.3.8

112.5

184889

1643.46

... More
Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1302

23

37852

1645.76

... More
Providing and laying filter material underneath pitching in slopes complete as per drawing and technical specifications Clause 1302

18.4

49300

2679.36

... More
Printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade as per drawings and Technical Specification Clause 1701

450

720

1.6

... More
"Providing and Laying hot applied thermoplastic road marking strip on Bituminous Surface of specified shade/ colour of 2.5 mm thick including 1.5 Refractive index reflectorizing glass beads @ 250gm/sqm thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC 35:2015. Initial Dry reflectivity RL shall be 250 mcd/sqm/lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/sqm/ lux and Qd of 100 mcd/sqm/ lux measured at the end of 2 years by means of a Standard Reflectometer of Zehntner, Easylux, Delta make capable of measuring RL & QD both according to IRC 35:2015 clause 15.5. The finished surface to be level, uniform, and free from streaks and holes complete as per direction of Engineer-in-charge and in accordance with applicable specifications.(Refer MORTH Clause 803 for technical Specification and Performance for IRC 35:2015)."

1000

739260

739.26

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 5th Kilometre Stone (precast)

1

4735

4735.57

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 Ordinary Kilometer Stone (Precast)

5

13904

2780.88

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 200 meter Stone (precast). as directed by Engineer in Charge.

24

13837

576.58

... More
Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704, as directed by Engineer in Charge.

500

329015

658.03

... More
Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered/concrete surfaces as per drawing and Technical Specification Clause 1701

197.29

31185

158.07

... More
Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 as directed by Engineer in Charge.

2

32471

16235.7

... More
Sign Board of MMGSY / PMGSY Project Information : Providing and fixing of typical retro reflective MMGSY / PMGSY Project informatory sign board with Logo as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing. The board will be a composite unit consisting of Three Plates ACP (Aluminum Composite Panel), material specificaitons as per clause 17001.3. The top most plate will be of 3mm ACP in diamond shape of 600x600mm size, riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. The middle 4mm ACP plate of will be 1200x150mm size riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. The main 4mm ACP lower most plate will be 1500mmx600mm size, riveted with MS angle iron frame of 25mmx25mmx5mm size. Riveting of all the sheets over angle and flat iron frame will be done neatly to have plain surface on one side. The angle iron frame of lower most plate and flat iron frame of the middle plate will be welded to two nos. 75mm x75mm x 12 swg sheet tubes posts placed at 1125mm apart centre to centre. the top of the middle plate will be flushed with the top of 75mm dia medium steel tube posts and these posts will be embeded in cement concrete M15 grade block of 450x450x600mm below ground level. The height of the bottom of the lower plate will be 1200mm from normal ground level and the bottom of the middle plate will be 100mm above the top level of the lower most plate. the diamond shaped plate mounted over flat angle iron frame will be connected to middle plate by square steel section of 47mmx47mm, thickness 12SWG having a spacing of 100mm between the diamond shaped plate and middle plate and this square section will be riveted to the bottom point of the diamond shaped plate. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no.

3

48707

16235.7

... More
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 1.5 mm thick supported on GI pipe 50 mm dia firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 1701 600 x 600 milimeter Square

2

5175

2587.64

... More
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 1.5 mm thick supported on GI pipe 50 mm dia firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 1701 600 mm equilateral triangular

25

64691

2587.64

... More
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 1.5 mm thick supported on GI pipe 50 mm dia firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 1701 900 x 600 milimeter reclangular

3

7762

2587.64

... More
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 1.5 mm thick supported on GI pipe 50 mm dia firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 1701. 600 x 450 mm Rectangular

2

5175

2587.64

... More
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 1.5 mm thick supported on GI pipe 50 mm dia firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 1701. 600 mm circular

2

5175

2587.64

... More
Providing and Fixing of Retro Reflectorised direction & place identification sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type IV standards of ASTM D4956-09 specifications, fixed over 4 mm thick ACP sheet supported with Back support frame of 35x35x5mm mild steel angle with areas not exceeding 0.9 sqm. Supported in mild steel angle iron post 75x75x6mm - 3.5 mtr height ,firmly fixed to the grounf by means of properly designed foundation of M 20 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level complete (as per MoRT&H specification No.801) (for area Less than 0.9 sqm). 7Both border & background shall be retro reflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor(Bottom of the board shall be at least 2.6 mtr. above ground level) Specification: IRC 67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective

3.6

13676

3799

... More
Supplying & Fixing of Molded Shank Raised Pavement Markers / Cat's Eye made of polycarbonate and ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face and shall support a load of 16000 kg tested in accordance to ASTM D 4280 Type H and complying to Specifications of Category A of MORTH Circular No RW/NH/33023/10-97 DO III Dt 11.06. 1997. The height, width and length shall not exceed 50 mm, 100 mm and 102 +/- 2 mm and with minimum reflective area of 13 Sqcm on each side and the slope to the base shall be 35 +/- 5 degree. The strength of detachment of the integrated cylindrical shanks, (of diameter not less than 19 +/- 2 mm and height not less than 30+/- 2 mm) from the body is to be a minimum value of 500 Kg. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturer's recommendation and complete as directed by the engineer.The contractor shall submit a two year warranty for satisfactory field performance including stipulated retro-reflectance of the reflecting panel, to the Engineer.

600

243756

406.26

... More
Road Delineators: Supplying and installation of delineators (Roadway Indicators, Hazard markers, Object markers) 80 to 100 cm high above ground level, painted black and white in 15 cm wide strips, fitted with 80x100mm rectangular or 75mm dia. Circular reflectorised panels at the top, buried or pressed into the ground and confirming to I.R.C. 79 and the drawings

130

118614

912.42

... More
Retroreflective tape (Engg Gr.)

90

104989

1166.55

... More
Shifting of Water Supply Lines ( Providing,layingandfixingP.V.C.pipeof50mmdia.withfittingssuchasbends,tees,reducers,clamps,etc.includingnecessaryexcavation,trenchfillingetc.complete.Includingremovingexistingpipelineifnecessaryandconveyingandstacking the same in PWD chowky or as directed etc. complete.)

81.9

38361

468.42

... More
Providing laterite stone machinery in civil mortal 1:6 per foundation and plinth including streaking joints on the unexpose faces and watering complete letterhead stone 6 sides cut and thickness of motor joints be 12 mm Max

36.5

263949

7231.5

... More
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. 600 NP3 Class

45

239360

5319.12



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.