Rural Development Department Tender
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Rural Development Department - RDD Tender
Civil And Construction
Building Construction
Eprocure
Opening Date1 Jul 2024
Closing Date11 Jul 2024
Tender AmountRefer Documents
Costs
EMD
₹ 12,000Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_SATAR_1046134_1Bid Award Id
ViewTender No
No.ZPSDV /2515/5/E-Ten/2024Tender Authority
Rural Development Department ViewPurchaser Address
-Website
http://https://rdd.maharashtra.gov.in/en
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Providing and laying in situ/Ready Mix cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete work in foundations like raft, strip foundations, grillage and footings of reinforced cement concrete columns and steel stanchions, excetra including bailling out water, formwork, cover blocks, compaction, curing and roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel), excetra complete, with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (using ARTIFICIAL SAND).
Item / Page No : 11 / 178
Specification No : Bd.F.3, B-7
Spec. Page No : 298, 38-40
Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
6.05
50044
8271.9
Providing and laying cast in situ / Ready Mix cement conrete M-20 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete columns as per detailed designs and drawing or as directed, including steel centering, formwork, cover blocks,aying/pumping, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete.with fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND).
Item / Page No : 31 / 179
Specification No : Bd.F.5, B-7
Spec. Page No : 300, 38-40
Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
4.86
75907
15618.8
Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks,laying/pumping, compaction and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND).
Item / Page No : 50 / 181
Specification No : Bd.F.6, B-7
Spec. Page No : 300-301, 38-40
Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
7.32
102138
13953.4
Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap/ granite / quartzite/ gneiss metal for reinforced cement concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks,laying / pumping, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND).
Item / Page No : 70 / 182
Specification No : Bd.F.8, B-7
Spec. Page No : 302-303, 38-40
Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
9.05
142833
15782.7
Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap metal for reinforced cement concrete chajja as per detailed design and drawings including centering, formwork, cover blocks, compacting, finishing and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate of natural sand/V.S.I. quality Artificial Sand (For Ground Floor) (using ARTIFICIAL SAND).
Item / Page No : 5 / 184
Specification No : BDF-9, B-7
Spec. Page No : 303-304, 38-40
Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
0.23
3630
15782.7
Filling in plinth and floors with approved excavated materials in 15 centimetre to 20 centimetre layers including watering and compacting, excetra complete.
Item / Page No : 36 / 157
Specification No : Bd.A.10
Spec. Page No : 262-263
8.16
1077
132
Filling in plinth and floors with contractors material / brought from outside and approved by Engineer In-Charge, in 15 centimetre to 20 centimetre layers including watering and compaction, excetra complete.
Item / Page No : 37 / 157
Specification No : Bd.A.11
Spec. Page No : 263-264
13.16
11614
882.55
Providing and fixing in position thermo mechnically treated FE-500 steel bar reinforcement of various dias for reinforced cement concrete pile caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardis, copings, fins, arches, excetra as per detailed designs, drawings and schedules including cutting, bendding, hooking the bars, binding with wires or tack welding and supporting as requied complete. (For Ground Floor)
Item / Page No : 33 / 188
Specification No : Bd.F.17
Spec. Page No : 306
2.16
213199
98886.75
Providing second class burnt brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 in foundations and plinth of inner walls / in plinth of external walls including bailling out water manually, striking joints, on unexposed faces, racking out joints on exposed faces and watering, excetra complete. (using ARTIFICIAL SAND).
Item / Page No : 1 / 197
Specification No : Bd.G.1
Spec. Page No : 313
Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
2.04
18399
9019.6
Providing second class Burnt Brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 superstructure including striking joints, racking out joints, watering and scaffolding, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).
Item / Page No : 5 / 197
Specification No : Bd.G.5
Spec. Page No : 315
Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
6.84
63492
9282.5
Providing second class Burnt Brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 superstructure including striking joints, racking out joints, watering and scaffolding, excetra complete. (For First Floor) (using ARTIFICIAL SAND).
Item / Page No : 5 / 197
Specification No : As per Item No 13
Spec. Page No : ---
Additional Specifications : As per Item No 13
6.22
58262
9366.9
Providing and fixing frame with / without ventilator of size as specified with non teak wood for doors and windows including chamfering, rounding, rebating holdfast of size 300 milimetre X 40 milimetre X 5 milimetre with oil painting, excetra complete. (For Ground Floor)
Item / Page No : 2 / 245
Additional Specifications : The work shall be done as per instructions of Engineer in charge.
0.1
11546
117823.2
Providing and fixing solid core flush door shutter in single leaf 32 milimetre thick decorative type of exterior grade as per detailed drawings, approved face veneers 3 milimetre thick on both faces or as directed, all necessary beeds, moulding and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides and finishing with french polish, excetra complete. (For Ground Floor)
Item / Page No : 9 / 246
Specification No : Bd.T.34
Spec. Page No : 499
3.33
11278
3386.9
Providing and fixing in position (as per Indian Standard : 1868/1982) aluminium sliding window of two tracks with rectangular pipe having overall dimentsions 63.50 milimetre X 38.10 milimetre X 1.02 milimetre at weight 0.547 kilogram per running metre and window frame bottom track section 61.85 milimetre X 31.75 milimetre X 1.20 milimetre at weight 0.695 kilogram per running metre. Top and side track section 61.85 milimetre X 31.75 milimetre X 1.30 milimetre at weight 0.659 kilogram per running metre. The shutter should be of bearing bottom 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre. Interlocking secion 40 milimetre X 18 milimetre X 1.10 milimetre at weight 0.469 kilogram per running metre and handle section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre and top section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre as per detailed drawing and as directed by Engineer in-charge with all necessary aluminium sections, fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 milimetre thick plain glass with all required screws and nuts, excetra complete. - With colour anodising with box. (For Ground Floor)
Item / Page No : 37 / 251
Additional Specifications : The work shall be carried out as per instructions of Engineer in charge.
8.42
50746
6026.9
Providing and fixing mild steel grill work for windows, ventilator, excetra 20 kilogram per square metre as per drawings including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting, excetra complete. (For Ground Floor)
Item / Page No : 1 / 264
Specification No : Bd.U.1
Spec. Page No : 537
8.64
19970
2311.35
Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates excetra as per detailed desings and drawings or as directed including cuting, fabricating, hoisting, erecting, fixing in position, making rivetted / bolted / welded connection and one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade, excetra complete. (For First Floor)
Item / Page No : 4 / 173
Specification No : Bd.C.8
Spec. Page No : 278
0.05
6507
132814.9
Providing internal cement plaster 20 milimetre thick in single coat in cement mortar 1:5 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing, excetra complete. (For Ground Floor) (using NATURAL SAND).
Item / Page No : 6 / 209
Specification No : Bd.L.4
Spec. Page No : 368
Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
95.41
40406
423.5
Providing internal cement plaster 12 milimetre thick in single coat in cement mortar 1:3 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing, excetra complete. (For Ground Floor) (using NATURAL SAND).
Item / Page No : 5 / 209
Specification No : Bd.L.2
Spec. Page No : 368
Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
108.36
35227
325.1
Providing internal cement plaster 6 milimetre thick in a single coat in cement mortar 1:4 without neeru finish to concrete surface in all positions including scaffolding and curing, excetra complete. (For Ground Floor) (using NATURAL SAND).
Item / Page No : 1 / 209
Specification No : Bd.L.1
Spec. Page No : 367
Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
54.46
12348
226.75
Providing and laying vitrified mirror / glossy finish tiles having size 590 milimetre to 605 milimetre X 590 milimetre to 605 milimetre of 8 milimetre to 10 milimetre thickness and confirming to Indian Standard 15622-2006 (Group BIa) of approved make, shade and pattern for dado and skirting in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).
Item / Page No : 41 / 217
Specification No : Bd.M.12
Spec. Page No : 385
Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
48.14
67740
1407.15
Providing and laying matt finish ceramic tiles of having sizes 30 centimetre X 30 centimetre and confirming to Indian Standard 15622 : 2006 (Group DII-A) and 7 milimetre to 8 milimetre thick for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with white / colour cement slurry, cleaning, curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).
Item / Page No : 24 / 215
Specification No : Bd.M.12
Spec. Page No : 385
Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
3.15
4189
1330.15
Providing and laying ceramic tiles of having sizes 30 centimetre X 30 centimetre and confirming to corrosponding Indian standared for dado and skirting in required position with ready made adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white / colour cement slurry, cleanding, curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).
Item / Page No : 25 / 215
Specification No : Bd.M.13
Spec. Page No : 386
Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
10.8
15232
1410.45
Providing and laying chequered tiles of approved quality of size 30 centimetre X 30 centimetre and confirming to indian standard for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning, curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).
Item / Page No : 66 / 220
Specification No : Bd.M.12
Spec. Page No : 385
Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
5.4
4531
839.15
Providing and applying washable oil bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces (excluding the primer coat), excetra complete. (For Ground Floor)
Item / Page No : 11 / 227
Specification No : Bd.P.5
Spec. Page No : 413
162.82
8596
52.8
Providing and applying two coats of waterproof cement paint of approved manufacture and of approved colour to the plastered surfaces including scaffolding if necessary, cleaning and preparing the surfaces, watering for two days, excetra complete. (For Ground Floor)
Item / Page No : 13 / 224
Specification No : Bd.O.8
Spec. Page No : 406
95.41
8291
86.9
Providing and fixing 10 centimetre cast iron nahani trap including cast iron grating, bend and piece of cast iron pipe upto the outside face of the wall complete. (For Ground Floor)
Item / Page No : 80 / 273
Specification No : Bd.V.32
Spec. Page No : 567
1
1239
1239.7
Providing and fixing Orissa type white glazed earrthenware 575 milimetre water closet pan including "S" trap with earthenware foot rests, cast iron soil and vent pipe upto outside face of the wall, 1:2:4 brick bat lime concrete bedding without flushing tank and its accessories excetra complete. (For Ground Floor)
Item / Page No : 30 / 277
Additional Specifications : The work shall be done as per instructions of Engineer in charge.
1
4407
4407.7
Providing and fixing white glazed earthenware wash hand basin of 45 centimetre X 30 centimetre size including cold water piller tap / cold and hot water piller tap brackts, rubber plugs and brass chain, stop tap and necessary pipe connections including polyvinyl chloride waste pipe and trap upto the outside face of the wall.Making good thedamaged surface, testing excetra complete. (For Ground Floor)
Item / Page No : 64 / 272
Specification No : Bd.V.30
Spec. Page No : 565
1
6325
6325
Providing and fixing of colour coated zincalume (R) AZ 150 (Minimum 150 grams per square metre total on each sides) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 milimetre base metal thickness (BMT) (0.5 milimetre TCT), Hi-strength steel with minium 550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55 percent aluminium, 43.4 percent zinc, 1.6 percent silicon) with COLORBOND (R) steel quality super durable polyster paint coat (with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nominal 950-1050 milimetre effective cover width and nominal 25-30 milimetre deep ribs with subtle square fluting in the five pan at nominal 180-250 milimetre center to centre. The end rib shall be designed for anti capilary groove and return leg. The feed material should have coil manufacturer's product details marked at regular interval. Including fasteners with minium fatened with minium 25 um zinc-tin alloy coated, hex head, self-drilling screw, excetra complete. (Weight of profile 4.52 kilogram per square metre). (For Ground Floor)
Item / Page No : 34 / 236
Additional Specifications : The work shall be done as per instructions of Engineer in charge.
18.45
23806
1290.3
Providing and laying 100 milimetre diameter salt glazed stoneware pipe including fittings such as bends, tees, single junction, double junctions laying, jointing (including excavation and refilling the trenches) complete.
Item / Page No : 3 / 274
Specification No : Bd.V.39
Spec. Page No : 573
3
1151
383.9
Providing and fixing on walls / celling / floor, 20 milimetre diameter chlorinated poly vinyl chloride pipe with necessary fittings, remaking good the demolished portion, excetra complete.Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed excetra complete. (For Ground Floor)
Item / Page No : 56 / 280
Specification No : Bd.V.5
Spec. Page No : 551
Additional Specifications : The work shall be done as per instructions of Engineer in charge.
5
1705
341
Providing and fixing 25 milimetre diameter screw down bib / stop tap of brass including necessary socket union nut complete. (For Ground Floor)
Item / Page No : 42 / 270
Specification No : Bd.V.8
Spec. Page No : 554
1
1502
1502.6
Providing and fixing 15 milimetre diameter screw down bib / stop tap of brass including necessary socket union nut complete. (For Ground Floor)
Item / Page No : 40 / 270
Specification No : Bd.V.8
Spec. Page No : 554
1
738
738.1
Providing soak pit of size 120 centimetre X 120 centimetre X 120 centimetre including excavating and filling with brick bats.
Item / Page No : 19 / 275
Specification No : Bd.V.46
Spec. Page No : 576
1
3247
3247.2
Providing, laying and fixing polyvinyl chloride pipe of 110 milimetre diameter with fittings such as bends, tees, reducers, clamps, excetra including necessary excavation, trench filling, excetra complete.Including removing existing pipe line if necessary and conveying and stacking thesame in PWD chowky or as directed excetra complete.
Item / Page No : 28 / 277
Additional Specifications : The work shall be done as per instructions of Engineer in charge.
4
2613
653.4
Providing and fixing hume pipe septic tank 900 milimetre diameter with vent pipe and cap including excavation and laying.
Item / Page No : 18 / 275
Specification No : Bd.V.45
Spec. Page No : 575
1
18796
18796.95
Provoding and fixing high density polyethylen container one piece moulded water tank made out of high density polyethylen and built corrugated inclusive of delivery upto destination housting, fixing of accessaries such as inlet, outlet, overflow pipe inclusive of all Taxes. Capacity between 200 litres to 1000 litres. (For Ground Floor)
Item / Page No : 53 / 280
Additional Specifications : The work shall be done as per instructions of Engineer in charge.
500
7700
15.4
Providing internal cement plaster 12 milimetre thick in a single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing, excetra complete. (For First Floor) (using NATURAL SAND).
Item / Page No : 4 / 209
Specification No : Bd.L.2
Spec. Page No : 368
Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
44.78
14128
315.5
Providing internal cement plaster 20 milimetre thick in single coat in cement mortar 1:5 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing, excetra complete. (For First Floor) (using NATURAL SAND).
Item / Page No : 6 / 209
Specification No : As per Item No 20
Spec. Page No : ---
Additional Specifications : As per Item No 20
46.97
20072
427.35
Laboratory testing charges for various materials required for items of work, on the basis of testing frequency and charges fixed by Vigilence and Quality Control Circle, Pune.
Item / Page No : 4 / 0
Additional Specifications : 1. The amount of laboratory testing charges will be paid to contractor only after submission of the original receipt from the Vigillence and Quality Control Office with the name of work mensioned on it. 2. Above / below percentage quoted by the contractor will not be applicable for this item.
1
4502
4502
Providing and fixing Road junction / Information sign board of size 0.90 metre X 0.60 metre prepared on 16 gauge mild steel sheet with angle iron frame of size 35 milimetre X 35 milimetre X 5 milimetre including painting with one coat of zinc cromate stoving primer and two coats each of green/ white back ground and back side gray stove enamelled, bonded with red retro-reflective sheet Engineering grade, border / letters / numeral / arrows, coated with non pealable crystal clear protective coat retaining 100 percent reflection including two angle iron post of size 50 milimetre X 50 milimetre X 5 milimetre of 3.65 metre long inflated at bottom drilled on top and painted in white and black bands of 30 centimetre. with 4 numbers high strength galvanised iron bolts and nuts of size 10 milimetre diameter and 20 milimetre long sheet and angle iron post in one piece without joints including all taxes, conveying, fixing in ground with cement concrete 1:4:8 block of 60 centimetre X 60 centimetre X 75 centimetre size as directed by Engineer-in-charge, excetra complete. Mild Steel Board with Engineering Grade.
Item / Page No : 47 / 64
Specification No : MoRTH-801
Spec. Page No : ---
Additional Specifications : The work shall be carried out as per instructions of Engineer in charge.