Rural Development Department Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Rural Development Department - RDD Tender

Works
Civil And Construction
Eprocure
Opening Date3 Feb 2025
Closing Date18 Feb 2025
Tender Amount₹ 97,61,776 
Notes
Download

Costs

  • EMD

    ₹ 97,618
  • Document Cost

    ₹ 18,000
  • Tender Fee

    ₹ 500

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing and laying in situ/Ready Mix cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete work in foundations like raft, strip foundations, grillage and footings of reinforced cement concrete columns and steel stanchions, excetra including bailling out water, formwork, cover blocks, compaction, curing and roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel), excetra complete, with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (using ARTIFICIAL SAND). Item / Page No : 11 / 178 Specification No : Bd.F.3, B-7 Spec. Page No : 298, 38-40 Additional Specifications : 1. The appropriate mix design shall be got done well in advance from the approved government laboratory and the same shall also be got approved from Engineer in-charge, before starting the work. 2. Cement from the same stock sent for mix design shall be used for concreting work. 3. The minimum cement for reinforced cement concrete / plain concrete to ensure durability / strength shall be as per IS 456-2000 with latest ammendment. If actual cement required / consumed is more than the provision in the IS code / approved mix design, no claim for that shall be entertained and cost for that shall be bourned by the contractor. 4. Before concreting work, cement from each consignment shall be got tested and if the strength of cement varies considerably from the approved mix design, the mix design should be got modified according to strength of fresh cement available in stock and concreting work should be done according to modified mix design. 5. For every consignment of cement, a sample shall be got tested as per norms and frequency of Vigilance and Quality Control Circle, Pune. As regards testing of cement it will be entire responsibility of the contractor. 6. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

16.43

8243

135433.31

... More
Providing and laying cast in situ / Ready Mix cement conrete M-20 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete columns as per detailed designs and drawing or as directed, including steel centering, formwork, cover blocks,aying/pumping, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete.with fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 31 / 179 Specification No : Bd.F.5, B-7 Spec. Page No : 300, 38-40 Additional Specifications : 1. The appropriate mix design shall be got done well in advance from the approved government laboratory and the same shall also be got approved from Engineer in-charge, before starting the work. 2. Cement from the same stock sent for mix design shall be used for concreting work. 3. The minimum cement for reinforced cement concrete / plain concrete to ensure durability / strength shall be as per IS 456-2000 with latest ammendment. If actual cement required / consumed is more than the provision in the IS code / approved mix design, no claim for that shall be entertained and cost for that shall be bourned by the contractor. 4. Before concreting work, cement from each consignment shall be got tested and if the strength of cement varies considerably from the approved mix design, the mix design should be got modified according to strength of fresh cement available in stock and concreting work should be done according to modified mix design. 5. For every consignment of cement, a sample shall be got tested as per norms and frequency of Vigilance and Quality Control Circle, Pune. As regards testing of cement it will be entire responsibility of the contractor. 6. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

14.31

15576

222901.15

... More
Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including centering, formwork, cover blocks, compacting, finishing and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement, including cover block) Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin excetra with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 23 / 185 Specification No : Bd.F.12, B-7 Spec. Page No : 304-305, 38-40 Additional Specifications : 1. The appropriate mix design shall be got done well in advance from the approved government laboratory and the same shall also be got approved from Engineer in-charge, before starting the work. 2. Cement from the same stock sent for mix design shall be used for concreting work. 3. The minimum cement for reinforced cement concrete / plain concrete to ensure durability / strength shall be as per IS 456-2000 with latest ammendment. If actual cement required / consumed is more than the provision in the IS code / approved mix design, no claim for that shall be entertained and cost for that shall be bourned by the contractor. 4. Before concreting work, cement from each consignment shall be got tested and if the strength of cement varies considerably from the approved mix design, the mix design should be got modified according to strength of fresh cement available in stock and concreting work should be done according to modified mix design. 5. For every consignment of cement, a sample shall be got tested as per norms and frequency of Vigilance and Quality Control Circle, Pune. As regards testing of cement it will be entire responsibility of the contractor. 6. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

10

8337

83374.5

... More
Providing second class burnt brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 in foundations and plinth of inner walls / in plinth of external walls including bailling out water manually, striking joints, on unexposed faces, racking out joints on exposed faces and watering, excetra complete. (using ARTIFICIAL SAND). Item / Page No : 1 / 197 Specification No : Bd.G.1 Spec. Page No : 313 Additional Specifications : 1. The brick shall be got tested before use, from the Government laboratory at the rate of one batch of 15 bricks for every 50000 bricks or part therof at the contractors cost for the following. A) Crushing strength:- i. Dry condition 5 bricks ii. Wet condition 5 bricks B) Water aborption 5 bricks 2. In addition, bricks shall be tested for size, shape and soundness. 3. The proportion of cement mortar shall be 1:6. 4. Minimum two drums of water shall be provided to masons for soaking of bricks at each place where masons are working. 5. For mixing of mortar steel forms of required size only shall be used For mixing of mortar, steel tough or back platform shall be used. 6. The brick work shall be cured for a minimum period of 14 days. 7. The joints on both faces shall be raked to a depth of not less than the thickness of joints for affording good bond plaster. 8. Hold fast of door or window frames shall be embedded in cast in situ 1:2:4 cement concrete blocks of required size without any extra cost. 9. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

20.63

9019

186034.14

... More
Filling in plinth and floors with contractors material / brought from outside and approved by Engineer In-Charge, in 15 centimetre to 20 centimetre layers including watering and compaction, excetra complete. Item / Page No : 37 / 157 Specification No : Bd.A.11 Spec. Page No : 263-264

77.34

877

67881.32

... More
Providing second class Burnt Brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 superstructure including striking joints, racking out joints, watering and scaffolding, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 5 / 197 Specification No : Bd.G.5 Spec. Page No : 315 Additional Specifications : 1. The brick shall be got tested before use, from the Government laboratory at the rate of one batch of 15 bricks for every 50000 bricks or part therof at the contractors cost for the following. A) Crushing strength:- i. Dry condition 5 bricks ii. Wet condition 5 bricks B) Water aborption 5 bricks 2. In addition, bricks shall be tested for size, shape and soundness. 3. The proportion of cement mortar shall be 1:6. 4. Minimum two drums of water shall be provided to masons for soaking of bricks at each place where masons are working. 5. For mixing of mortar steel forms of required size only shall be used For mixing of mortar, steel tough or back platform shall be used. 6. The brick work shall be cured for a minimum period of 14 days. 7. The joints on both faces shall be raked to a depth of not less than the thickness of joints for affording good bond plaster. 8. Hold fast of door or window frames shall be embedded in cast in situ 1:2:4 cement concrete blocks of required size without any extra cost. 9. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

50.09

9281

464927.87

... More
Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks,laying/pumping, compaction and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 50 / 181 Specification No : Bd.F.6, B-7 Spec. Page No : 300-301, 38-40 Additional Specifications : 1. The appropriate mix design shall be got done well in advance from the approved government laboratory and the same shall also be got approved from Engineer in-charge, before starting the work. 2. Cement from the same stock sent for mix design shall be used for concreting work. 3. The minimum cement for reinforced cement concrete / plain concrete to ensure durability / strength shall be as per IS 456-2000 with latest ammendment. If actual cement required / consumed is more than the provision in the IS code / approved mix design, no claim for that shall be entertained and cost for that shall be bourned by the contractor. 4. Before concreting work, cement from each consignment shall be got tested and if the strength of cement varies considerably from the approved mix design, the mix design should be got modified according to strength of fresh cement available in stock and concreting work should be done according to modified mix design. 5. For every consignment of cement, a sample shall be got tested as per norms and frequency of Vigilance and Quality Control Circle, Pune. As regards testing of cement it will be entire responsibility of the contractor. 6. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

7

13914

97399.4

... More
Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap metal for reinforced cement concrete chajja as per detailed design and drawings including centering, formwork, cover blocks, compacting, finishing and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate of natural sand/V.S.I. quality Artificial Sand (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 5 / 184 Specification No : BDF-9, B-7 Spec. Page No : 303-304, 38-40 Additional Specifications : 1. The appropriate mix design shall be got done well in advance from the approved government laboratory and the same shall also be got approved from Engineer in-charge, before starting the work. 2. Cement from the same stock sent for mix design shall be used for concreting work. 3. The minimum cement for reinforced cement concrete / plain concrete to ensure durability / strength shall be as per IS 456-2000 with latest ammendment. If actual cement required / consumed is more than the provision in the IS code / approved mix design, no claim for that shall be entertained and cost for that shall be bourned by the contractor. 4. Before concreting work, cement from each consignment shall be got tested and if the strength of cement varies considerably from the approved mix design, the mix design should be got modified according to strength of fresh cement available in stock and concreting work should be done according to modified mix design. 5. For every consignment of cement, a sample shall be got tested as per norms and frequency of Vigilance and Quality Control Circle, Pune. As regards testing of cement it will be entire responsibility of the contractor. 6. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

0.48

15740

7586.78

... More
Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap/ granite / quartzite/ gneiss metal for reinforced cement concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks,laying / pumping, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 70 / 182 Specification No : Bd.F.8, B-7 Spec. Page No : 302-303, 38-40 Additional Specifications : 1. The appropriate mix design shall be got done well in advance from the approved government laboratory and the same shall also be got approved from Engineer in-charge, before starting the work. 2. Cement from the same stock sent for mix design shall be used for concreting work. 3. The minimum cement for reinforced cement concrete / plain concrete to ensure durability / strength shall be as per IS 456-2000 with latest ammendment. If actual cement required / consumed is more than the provision in the IS code / approved mix design, no claim for that shall be entertained and cost for that shall be bourned by the contractor. 4. Before concreting work, cement from each consignment shall be got tested and if the strength of cement varies considerably from the approved mix design, the mix design should be got modified according to strength of fresh cement available in stock and concreting work should be done according to modified mix design. 5. For every consignment of cement, a sample shall be got tested as per norms and frequency of Vigilance and Quality Control Circle, Pune. As regards testing of cement it will be entire responsibility of the contractor. 6. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

7.91

15740

124504.98

... More
Providing and fixing in position thermo mechnically treated FE-500 steel bar reinforcement of various dias for reinforced cement concrete pile caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardis, copings, fins, arches, excetra as per detailed designs, drawings and schedules including cutting, bendding, hooking the bars, binding with wires or tack welding and supporting as requied complete. (For Ground Floor) Item / Page No : 33 / 188 Specification No : Bd.F.17 Spec. Page No : 306 Additional Specifications : 1. Steel to be used must be as per Indian Standard : 1786 (1985) with latest amendments and manufactured by approved and reputed make. 2. Steel to be used must be procured directly from the manufacturers or from authorised agent of main producers. 3. Various diameters of TMT-FE-500 steel bars brought on site of the work shall be got tested category wise and lot wise, as directed by the Engineer In-Charge and minimum 50 percent of testing should be done in the departmental laboratory.

5.48

98729

541332.48

... More
Providing and fixing frame with / without ventilator of size as specified with country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300 milimetre X 40 milimetre X 5 milimetre with oil painting, excetra complete. (For Ground Floor) Item / Page No : 1 / 245 Additional Specifications : The work shall be done as per instructions of Engineer in charge.

0.09

219654

19549.29

... More
Providing and fixing single or double leaf panelled door shutter excluding frame with glazed openable fanlight shutter 35 milimetre thick as per detailed drawing consisting of panelled vertical styles 100 milimetre X 35 milimetre and lock and bottom rail 200 milimetre X 35 milimetre and panels 12 milimetre thick both side commercial ply faced partical board, including stainless steel fixtures and fastening and teak wood beading at junctions of panel insert and as instructed by the Engineer In charge including three coats of oil painting, excetra complete. (For Ground Floor) Item / Page No : 7 / 246 Additional Specifications : 1. The work shall be done as per instructions of Engineer in charge. 2. Door shutter and fixtures and fastenings shall be got approved by Engineer in-charge.

2.64

8054

21265.07

... More
Providing and fixing mild steel grill work for windows, ventilator, excetra 20 kilogram per square metre as per drawings including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting, excetra complete. (For Ground Floor) Item / Page No : 1 / 264 Specification No : Bd.U.1 Spec. Page No : 537 Additional Specifications : 1. The work shall be done as per instructions of Engineer in charge. 2. The grill design shall be got approved from the Engineer in-charge before use.

10.08

2307

23260.61

... More
Providing and fixing in position (as per Indian Standard : 1868/1982) aluminium sliding window of two tracks with rectangular pipe having overall dimentsions 63.50 milimetre X 38.10 milimetre X 1.02 milimetre at weight 0.547 kilogram per running metre and window frame bottom track section 61.85 milimetre X 31.75 milimetre X 1.20 milimetre at weight 0.695 kilogram per running metre. Top and side track section 61.85 milimetre X 31.75 milimetre X 1.30 milimetre at weight 0.659 kilogram per running metre. The shutter should be of bearing bottom 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre. Interlocking secion 40 milimetre X 18 milimetre X 1.10 milimetre at weight 0.469 kilogram per running metre and handle section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre and top section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre as per detailed drawing and as directed by Engineer in-charge with all necessary aluminium sections, fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 milimetre thick plain glass with all required screws and nuts excetra complete. - With powder coating without box. (For Ground Floor) Item / Page No : 40 / 252 Additional Specifications : The work shall be done as per instructions of Engineer in charge.

10.08

5340

53833.75

... More
Providing internal cement plaster 6 milimetre thick in a single coat in cement mortar 1:3 without neeru finish to concrete surface in all positions including scaffolding and curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 2 / 209 Specification No : Bd.L.1, Spec. Page No : 367 Additional Specifications : 1. The surface to be plastered shall be first cleaned and thoroughly wetted for 24 hours and got checked from Engineer in-charge before starting the work. 2. Item includes rounding of all internal and external junctions, corners, jambs, etc. as directed by the Engineer in-charge. 3. Finishing shall be plain and in line, level and plumb. 4. Curing shall be done by sprinkling water on the surface for minimum period of 14 days. 5. Application of sand faced treatment shall be commenced only after passing the base coat Engineer in-charge. 6. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

60.84

232

14130.09

... More
Providing internal cement plaster 12 milimetre thick in a single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 4 / 209 Specification No : Bd.L.2, Bd.L.10 Spec. Page No : 368, 370 Additional Specifications : 1. The surface to be plastered shall be first cleaned and thoroughly wetted for 24 hours and got checked from Engineer in-charge before starting the work. 2. Item includes rounding of all internal and external junctions, corners, jambs, etc. as directed by the Engineer in-charge. 3. Finishing shall be plain and in line, level and plumb. 4. Curing shall be done by sprinkling water on the surface for minimum period of 14 days. 5. Application of sand faced treatment shall be commenced only after passing the base coat Engineer in-charge. 6. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

90.11

381

34408.5

... More
Providing sand faced plaster externally in cement mortar using approved screened sand in all positions including base coat of 15 milimetre thick in cement mortar 1:4 using waterproofing compound at one killogramme per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment of 6 to 8 milimetre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days, scaffolding, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 11 / 209 Specification No : Bd.L.7 Spec. Page No : 369 Additional Specifications : 1. The surface to be plastered shall be first cleaned and thoroughly wetted for 24 hours and got checked from Engineer in-charge before starting the work. 2. Item includes rounding of all internal and external junctions, corners, jambs, etc. as directed by the Engineer in-charge. 3. Finishing shall be plain and in line, level and plumb. 4. Curing shall be done by sprinkling water on the surface for minimum period of 14 days. 5. Application of sand faced treatment shall be commenced only after passing the base coat Engineer in-charge. 6. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

485.08

713

345959.06

... More
Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 milimetre to 605 milimetre X 590 milimetre to 605 milimetre of 8 milimetre to 10 milimetre thickness and confirming to Indian Standard 15622-2006 (Group BIa) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 40 / 217 Specification No : Bd.M.12 Spec. Page No : 385 Additional Specifications : 1. The work shall be carried out as per instructions of Engineer in-charge. 2. The work shall be carried out as per the sample approved by the Engineer in-charge and kept in the office of the Executive Engineer. 3. Water absorption should not be more than 0.05 percent. 4. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

65.31

1324

86503.1

... More
Providing and laying vitrified mirror / glossy finish tiles having size 590 milimetre to 605 milimetre X 590 milimetre to 605 milimetre of 8 milimetre to 10 milimetre thickness and confirming to Indian Standard 15622-2006 (Group BIa) of approved make, shade and pattern for dado and skirting in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 41 / 217 Specification No : Bd.M.12 Spec. Page No : 385 Additional Specifications : 1. The work shall be carried out as per instructions of Engineer in-charge. 2. The work shall be carried out as per the sample approved by the Engineer in-charge and kept in the office of the Executive Engineer. 3. Water absorption should not be more than 0.05 percent. 4. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

2.67

1406

3756.29

... More
Providing and laying in position flooring of telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone of approved shade and size 18 milimetre to 20 milimetre thick on a bed of 1:6 cement mortar including cement float, striking joints, pointing in cement mortar 1:3, curing and cleaning, excetra complete. (For Ground Floor) (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 34 / 216 Specification No : Bd.M.3 B Spec. Page No : 380 Additional Specifications : 1. The work shall be carried out as per the sample approved by the Engineer in-charge and kept in the office of the Executive Engineer. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

5.27

4428

23338.2

... More
Providing and laying green marble 18 milimetre to 20 milimetre thick for door frame / dado / window boxing excetra on cement mortar 1:6 including filling joints with polymer base filler, nosing / moulding the sharp edges wherever necessary, curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 48 / 218 Specification No : Bd.M.12 Spec. Page No : 385 Additional Specifications : 1. The work shall be carried out as per instructions of Engineer in-charge. 2. The work shall be carried out as per the sample approved by the Engineer in-charge and kept in the office of the Executive Engineer. 3. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

8.4

2608

21909.3

... More
Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in cement mortar 1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with cement mortar 1:3 admixed with approved water proofing compound and finally top finishing with average 20 milimetre thick layers of same mortar added with jute fiber at one kilogram per bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300 milimetre X 300 milimetre, making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 4 / 205 Additional Specifications : 1. The work shall be carried out as per instructions of Engineer in charge. 2. The amount of 10 percent of the total cost of the item shall be retained as retaintion money for the entire gaurantee period of 10 years. 3. The procedure of execution of this item should be got approved from the Engineer in-charge. 4. The contractor has to sign the gaurantee bond on stamp paper worth Rs. 100.00 5. The work shall be carried out as per the wording of the item and as per the guideline specification for waterproofing work. 6. Smooth finish over brick bat coba and for chamfer in cement mortar 1:3 should be done with proper line. 7. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

49.56

1339

66378.19

... More
Providing and applying white wash in two coats on old / new plastered or masonry surfaces and asbetos cement sheets including scaffolding and preparing the surface by brushing and brooming down, excetra complete. (For Ground Floor) Item / Page No : 3 / 227 Specification No : Bd.P.1 Spec. Page No : 411 Additional Specifications : 1. The priming coat should be applied and got approved from Engineer in-charge. 2. The shade of paints shall be got approved by the Engineer in-charge before use. 3. The paints shall be of Indian Standards and from approved manufactures. The paints shall be got approved before use.

60.84

13

803.09

... More
Providing and applying pearl / luster finish paint of approved colour and shade to the existing plastered surface including scaffolding, preparing the surface, applying the acrylic wall putti, excetra complete. (For Ground Floor) Item / Page No : 23 / 225 Additional Specifications : 1. The shade of paints shall be got approved by the Engineer in-charge before use. 2. The paints shall be of Indian Standards and from approved manufactures. The paints shall be got approved before use. 3. The work shall be carried out as per instructions of Engineer in charge.

90.11

237

21369.59

... More
Providing and applying two coats of exterior weather shield paint of approved manufacturer and of approved colour to the plastered surfaces including cleaning, preparing the plaster surfaces, applying primer coat, scaffolding, if necessary and watering the surface for two days, excetra complete. (For Ground Floor) Item / Page No : 26 / 225 Additional Specifications : 1. The shade of paints shall be got approved by the Engineer in-charge before use. 2. The paints shall be of Indian Standards and from approved manufactures. The paints shall be got approved before use.

218.08

323

70636.11

... More
Providing and fixing heavy duty inter locking concrete rubber mould glossy paving blocks of 60 milimetre thickness of having a strength of 400 kilogram per square centimetre of approved quality and shape on a bed of crushed sand of 25 milimetre to 30 milimetre thick including striking joints and cleaning excetra complete.(using 100 per cent crushed sand), excetra complete. Item / Page No : 53 / 219 Specification No : Bd.M-12 Spec. Page No : 385 Additional Specifications : 1. The work shall be carried out as per instructions of Engineer in-charge. 2. The work shall be carried out as per the sample approved by the Engineer in-charge and kept in the office of the Executive Engineer.

135.75

1237

168044.93

... More
Providing and laying Cast in situ / Ready Mix cement concrete M-15 of trap / granite / quartzite / gneiss metal for bed blocks, foundation blocks and such other items including bailling out water, plywood / steel formwork, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing, excetra complete. The cement mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin, excetra (Wooden centering will not be allowed.) with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (using ARTIFICIAL SAND). Item / Page No : 8 / 176 Specification No : Bd.E.4, B-7 Spec. Page No : 289-290, 38-40 Additional Specifications : 1. The appropriate mix design shall be got done well in advance from the approved government laboratory and the same shall also be got approved from Engineer in-charge, before starting the work. 2. Cement from the same stock sent for mix design shall be used for concreting work. 3. The minimum cement for reinforced cement concrete / plain concrete to ensure durability / strength shall be as per IS 456-2000 with latest ammendment. If actual cement required / consumed is more than the provision in the IS code / approved mix design, no claim for that shall be entertained and cost for that shall be bourned by the contractor. 4. Before concreting work, cement from each consignment shall be got tested and if the strength of cement varies considerably from the approved mix design, the mix design should be got modified according to strength of fresh cement available in stock and concreting work should be done according to modified mix design. 5. For every consignment of cement, a sample shall be got tested as per norms and frequency of Vigilance and Quality Control Circle, Pune. As regards testing of cement it will be entire responsibility of the contractor. 6. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

0.92

7439

6844.2

... More
Providing and fixing 90 centimetre X 60 centimetre marble name plate engraving 10 centimetre height letter, figures including painting the letters / figures with approved colour and shade complete. Item / Page No : 11 / 294 Specification No : Bd.W.7 Spec. Page No : 586-587

1

8393

8393.1

... More
Excavation for foundation in hard murum including removing the excavated material upto a distance of 50 metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting excetra complete. (Lift upto 1.5 metre) By Mechanical Means Item / Page No : 6 / 153 Specification No : Bd.A.2 Spec. Page No : 259 Additional Specifications : The useful excavated material shall be utilised as directed by the Engineer in-charge.

21.38

249

5328.97

... More
Providing and fixing 50 milimetre diameter medium class galvanised iron pipe gate with wicked gate of approved drawing with all fixtures and fittings in two leaves with strong hold fast embedded in cement concrete block at top and bottom with locking arrangement incluing cutting, bending, making holes and with one coat of primer, excetra complete. Item / Page No : 5 / 173 Additional Specifications : The work shall be done as per instructions of Engineer in charge.

5.75

7968

45817.15

... More
Providing and laying in situ cement concrete M-20 with tremix treatment for 100 milimetre thickness for flooring with groove cutting of 4 milimetre wide 20 milimetre deep with necessary refilling with bitumen, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 30 / 216 Additional Specifications : 1. The appropriate mix design shall be got done well in advance from the approved government laboratory and the same shall also be got approved from Engineer in-charge, before starting the work. 2. Cement from the same stock sent for mix design shall be used for concreting work. 3. The minimum cement for reinforced cement concrete / plain concrete to ensure durability / strength shall be as per IS 456-2000 with latest ammendment. If actual cement required / consumed is more than the provision in the IS code / approved mix design, no claim for that shall be entertained and cost for that shall be bourned by the contractor. 4. Before concreting work, cement from each consignment shall be got tested and if the strength of cement varies considerably from the approved mix design, the mix design should be got modified according to strength of fresh cement available in stock and concreting work should be done according to modified mix design. 5. For every consignment of cement, a sample shall be got tested as per norms and frequency of Vigilance and Quality Control Circle, Pune. As regards testing of cement it will be entire responsibility of the contractor. 6. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

630.9

932

588093.43

... More
Excavation for roadway in earth, soil of all sorts, sand, gravel or soft murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50 metre and spreading for embankment or stacking as directed. By Mechanical Means. Item / Page No : 11 / 23 Specification No : MORTH-301 Spec. Page No : 45-53 Additional Specifications : The useful excavated material shall be utilised as directed by the Engineer in-charge.

232.5

130

30376.13

... More
Supplying trap metal of required size by bringing the boulders / rubble at the road side breaking them to required gradation including conveying the boulders / rubble and stacking the broken metal, excetra complete. (Prior approval of sample stack of broken metal by the Executive Engineer is necessary the date of approval will form part of the measurements) - 60 milimetre metal, by breaking rubble obtained by blasting. (Hand broken). Item / Page No : 54A / 345 Additional Specifications : 1. Work shall be carried out as per the instructions of Engineer In-Charge. 2. Prior approval of sample stack of broken metal by the Executive Engineer is necessary. The date of approval will form part of the measurements.

155

1195

185225

... More
Supplying trap metal of required size by bringing the boulders / rubble at the road side breaking them to required gradation including conveying the boulders / rubble and stacking the broken metal, excetra complete. (Prior approval of sample stack of broken metal by the Executive Engineer is necessary the date of approval will form part of the measurements) - 40 milimetre metal, by breaking rubble obtained by blasting. (Hand broken). Item / Page No : 55 / 345 Additional Specifications : 1. Work shall be carried out as per the instructions of Engineer In-Charge. 2. Prior approval of sample stack of broken metal by the Executive Engineer is necessary. The date of approval will form part of the measurements.

159.89

1249

199846.51

... More
Supplying hard murum / kankar at the road site, including conveying and stacking, excetra complete. Item / Page No : 29a / 25 Specification No : MORTH-408 Spec. Page No : 139-142

206.66

697

144167.41

... More
Supplying soft murum at the road site, including conveying and stacking, excetra complete. Item / Page No : 29b / 25 Specification No : MORTH-408 Spec. Page No : 139-142

39.97

694

27753.25

... More
Spreading 60 mm metal for road work including sectionong, excetra complete as directed by Engineer in charge. Item / Page No : 58A / 346 Additional Specifications : Work shall be carried out as per the instructions of Engineer In-Charge.

155

93

14469.25

... More
Spreading 80 milimetre / 40 milimetre metal for road work including sectionong, excetra complete as directed by Engineer in charge. Item / Page No : 58 / 346 Additional Specifications : Work shall be carried out as per the instructions of Engineer In-Charge.

159.89

93

14925.73

... More
Spreading hard murum / soft murrum / gravel or kankar for side width, excetra complete. Item / Page No : 30 / 25 Specification No : MORTH-408 Spec. Page No : 139-142

246.64

86

21395.59

... More
Compacting the sub grade/gravel/oversize metal (200 milimetre loose) layers for all width with Power roller having weight 8 to 10 MT. including necessary, labour, materials and artificial watering complete. Item / Page No : 59 / 346 Additional Specifications : Work shall be carried out as per the instructions of Engineer In-Charge.

775

29

22978.75

... More
Compacting the sub grade / gravel / size metal (100 milimetre loose) layers for all widths with Power roller having weight 8 to 10 MT. including necessary, labour, materials and artificial watering complete. Item / Page No : 61 / 346 Additional Specifications : Work shall be carried out as per the instructions of Engineer In-Charge.

1598.9

27

43889.81

... More
Compacting the hard murum / kankar (upto 200 milimetre loose) with power roller including artificial watering complete. Item / Page No : 26aiii / 130 Specification No : RD.38 Spec. Page No : 210 Additional Specifications : The contract rate is for one square metre instead of one kilometre as mentioned in the specification.

775

6

5308.75

... More
Providing and constructing 75 milimetre thick modified penetration macadam road surface including all materials, preparing the existing road surface, spreading 40 milimetre stone metal layers 30 percent crusher broken metal plus 70 percent hand broken (by breaking rubble obtained by blasting), heating and spraying the bitumen of of specified grade at the rate of 2 kilogram per square metre, spreading 12 milimetre size chips, compacting with three wheel static roller having weight 8 to 10 metric tonnes to achive the desired degree of compaction as per technical specification Clause 506, excetra complete. Including picking of existing water bound macadam surface. (Using VG-30 bulk bitumen) Item / Page No : 35a / 31 Specification No : IRC-SP-20 Spec. Page No : 215

1598.9

358

573125.71

... More
Providing and constructing 75 milimetre thick modified penetration macadam road surface including all materials, preparing the existing road surface, spreading 40 milimetre stone metal layers 30 percent crusher broken metal plus 70 percent hand broken (by breaking rubble obtained by blasting), heating and spraying the bitumen of specified grade at the rate of 2 kilogram per square metre, spreading 12 milimetre size chips, compacting with three wheel static roller having weight 8 to 10 metric tonnes to achive the desired degree of compaction as per technical specification Clause 506, excetra complete, including applying tack coat of specified grade bitumen at the rate of 0.30 kilogram per square metre on existing bitumen surface. (Using VG-30 bulk bitumen) Item / Page No : 36a / 31 Specification No : IRC-SP-20 Spec. Page No : 215

2712.5

356

966599.38

... More
Providing 20 milimetre thick premix bituminous carpet including supplying all materials, preparing and cleaning the base, heating bitumen, applying tack coat at specified rate, mixing hot bitumen and chips, laying the carpet layer and compacting, excetra complete. By bulk asphalt.. (Excluding Tack Coat) (Cold Mix with prior approval) (Basic Carpet Rate approved by S.E. P.W. Circle, Ratnagiri Vide Letter No 3828 dated 23/09/2022) Item / Page No : 7-New / 0 Specification No : MORTH-511, MORTH-503 Spec. Page No : 149-162, 205-207, 198-205, 417-421, 19-21, 168-170 Additional Specifications : The work shall be carried out as directed by Engineer-In-Charge. 1. The work shall be carried out in day time and in dry wheather. 2. The representative of contractor shall maintain a register giving details of challens for bitumen received and should get it signed from the representative incharge of the Department in token of its acceptance. 3. For controlling trafic and maintening diversion during construction, no extra payment shall be made. 1. The work shall be carried out in day time and in dry wheather. 2. The representative of contractor shall maintain a register giving details of challens for bitumen received and should get it signed from the representative incharge of the Department in token of its acceptance. 3. For controlling trafic and maintening diversion during construction, no extra payment shall be made.

4311.4

289

1247934.73

... More
Royalty charges for various building construction bonafied materials which are used for government bonafied works and for which Royalty charges are to be paid by the contractor. (This Item is to be paid to the contractor only after he pays the Royalty amount to Revenue department and produces the required voucher.) Item / Page No : 3 / 0 Additional Specifications : 1. Government of Maharashtra, Revenue and Forest Department Gazette Number 146 Dated 04/06/2021 and Government of Maharashtra Public Works Department State Schedule of Rates 2021-22 General Note Number A(v), Page 5. 2. The amount of royalty charges will be paid only after submission of the receipt in original from Revenue authority for payment of royalty to Government, stating the name of work. 3. Above / below percentage quoted by the contractor will not be applicable for this item.

1079.1

216

233278.76

... More
Laboratory testing charges for various materials required for items of work, on the basis of testing frequency and charges fixed by Vigilence and Quality Control Circle, Pune. Item / Page No : 4 / 0 Additional Specifications : 1. The amount of the laboratory testing charges will be paid to the contractor after submission of the original receipt from the Office of the Vigilance and Quality Control with name of work mensioned on the original receipt within the stipulated period of work. 2. The frequency of tests will be as per the instructions of Vigilance and Quality Control, Pune; vide their letter No. Prasha/2647/ 2010 dated 30/10/2010. 3. No extra claim shall be entertained on account of additional tests required and material transportation charges for tests. 4. In addition to above, the conditions under clause 25 - Samples and Testing of Material, under 'Additional General Conditions and Specifications' of this tender document shall be applicable. 5. Above / below percentage quoted by the contractor will not be applicable for this item.Crushing Value / Compressive Strength, Water Absorption, Specific Gravity Test for Stone / Rubble 1 Test per Source

1

81835

81835

... More
Providing and fixing Road junction / Information sign board of size 0.90 metre X 0.60 metre prepared on 16 gauge mild steel sheet with angle iron frame of size 35 milimetre X 35 milimetre X 5 milimetre including painting with one coat of zinc cromate stoving primer and two coats each of green/ white back ground and back side gray stove enamelled, bonded with red retro-reflective sheet Engineering grade, border / letters / numeral / arrows, coated with non pealable crystal clear protective coat retaining 100 percent reflection including two angle iron post of size 50 milimetre X 50 milimetre X 5 milimetre of 3.65 metre long inflated at bottom drilled on top and painted in white and black bands of 30 centimetre. with 4 numbers high strength galvanised iron bolts and nuts of size 10 milimetre diameter and 20 milimetre long sheet and angle iron post in one piece without joints including all taxes, conveying, fixing in ground with cement concrete 1:4:8 block of 60 centimetre X 60 centimetre X 75 centimetre size as directed by Engineer-in-charge, excetra complete. Mild Steel Board with Engineering Grade. Item / Page No : 47 / 64 Specification No : MoRTH-801 Spec. Page No : --- Additional Specifications : The work shall be carried out as per instructions of Engineer in charge.

2

8579

17159.5

... More
Add Insurances 1% Non-Dsr Item Additional Specifications : The work shall be carried out as per the instructions of Engineer in-charge.

1

79384

79384

... More
Add GST.18% Non-Dsr Item Additional Specifications : The work shall be carried out as per the instructions of Engineer in-charge.

1

1428907

1428907



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.