Rural Development Department Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Rural Development Department - RDD Tender

Works
Civil And Construction
Civil Works Others
Eprocure
Opening Date19 Dec 2022
Closing Date31 Dec 2022
Tender Amount₹ 2,87,25,880 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Lift 1.50 to 3.00 m

75.36

-

364.1

... More
Lift 3.00 to 4.50 m

66.23

-

393.8

... More
Lift 4.50 to 6.00 M.

57.7

-

423.5

... More
Excavation in general in hard material comprising of soft rock, hard rock, Manjara rock, etc, by blasting / controlled blasting, chiselling as required in wet or dry condition for Head Works i.e. Intake Well, Connecting Pipe, Jack Well, Pump House, supply Well, etc. for lift 0 to 1.5 M and lead of 150 M including baricading, guarding, disposing off surplus excavated stuff within a radius of 0.5 km. as directed by Engineer-in-charge, excluding refilling. Lift 6.0 to 7.50 M

42.39

-

900.9

... More
Lift 7.50 to 9.00 m

42.39

-

931.7

... More
Lift 9.00 to 10.50 m

42.39

-

962.5

... More
Lift 10.50 to 12.00 m

42.39

-

993.3

... More
Lift 12.0 to 13.50 m

42.39

-

1024.1

... More
Lift 13.50 to 15.00 m

42.39

-

1054.9

... More
Lift 15.00 to 16.00 m

28.26

-

1085.7

... More
Dewatering the excavated trenches and pools of water in the building trenches / pipeline trenches, well works by using pumps and other devices including disposing off water to safe distance as directed by Engineer-in-charge (including cost of machinery, labour, fuel), etc. complete.

1500

-

84.7

... More
Providing and laying in situ Cement concrete of trap/granite/quartzite/ gneiss metal for PCC work below foundation and footing including normal dewatering,plywood form work, compaction, finishing and curing, etc, complete.

6.99

-

6824.4

... More
Providing and casting in situ C. C. of trap/granite/quartzite/ gneiss metal of approved quality for RCC work as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, plywood form work,bully/steel prop ups, compaction, finishing the formed surfaces with CM 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finssh is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use fo L&T, A.C. C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted .) Excluding M.S.or Tor reinforcement a) R.C.C. Ring Beam ,M250

2.8

-

9541.4

... More
b) R.C.C. Ring Wall ,M200

27.27

-

10244.3

... More
Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundation, slabs, beams, columns, canopies, staircases. newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete.(including cost of binding wire) Tor Steel

2.1

-

98286.3

... More
Providing stuctural steel work in single stanchions composed of RSJ, channel, etc, with caps, bases, mild steel plates, angles, brackets, cleats, gusset plates, anchor bolts, etc. as per detailed design and drawing or as directed by Engineer-in-charge including cutting, fabrication, hoisting, erecting, fixing in position, making riveted/ bolted / welded connections and one coats of anticorrosive paint and over it two coats of oil painting, etc. complete.

0.31

-

77018.7

... More
Providing and fixing M.S. chaquerred plate flooring of following thickness supported on M.S.angles (25 x 25 x 8 mm size) including welding, cutting and fabricating the plate to the required square or rounding shape, making holes in the plate, including providing and applying 3 coats of anticorrosive paint, etc. complete as directed by Engineer-in-charge. 8mm Thick

12

-

5622.1

... More
Providing and filling around the well boulders filling of selected variety and size of boulders including cost of all materials, labour, transportation, etc. complete with all leads and lifts.

204.21

-

1071.4

... More
Providing and fixing in position C.I. Type dapuri steps of 22 mm dia. M.S. bar step with proper anchorage, etc. and providing and applying 3 coats of ant-corrosive paint, etc complete as directed by Engineer-in-charge.

14

-

425.7

... More
Providing, and fixing 80 mm dia A.C./P.V.C. pipe weep holes at 1.5 M c/c staggered including cost of all materials and labour involved with all leads and lifts.etc. complete with all leads and lifts.

12

-

221.1

... More
Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete.

287.91

-

92.4

... More
Drilling of horizontal bores in soft and hard strata 150mm dia.by D.T.C machine including transportation of machine at site.

120

-

405.9

... More
Carrying out recuperation / yeild test for ascerting the discharge of constructed well / excavated profile as direrted by Engineer in charge.The test carried out by drawing down water from the well/ profile below normal / subsoil water level upto full depth rise in water level is recorded. The normal water level / subsoil water level in the well / profile as well as strainer / suction level at pump as per design of W.S. scheme shall be recorded prior. to the test including cost of all materials. overhead, labours etc. completed as directed. The test shall be carried out as per technical circular No.2597 dt. 20/11/97 and shall be carried out for 7 days.

7

-

2383.7

... More
S.W. No. 02:-CONSTRUCTION OF SWITCH ROOM (3.0 X 3.0 X 3.0 M) Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means

3.76

-

165

... More
Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 cm to 20 cm thick including hand packing and compacting etc. complete.

2.35

-

1292.5

... More
Filling in plinth and floors / trenches with contractor’s murum for bedding in 15cm to 20cm layers including watering and compaction complete.

4.68

-

911.9

... More
Providing and laying in situ 1:3:6 (M-100) grade of C.C. of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including dewatering from work, compacting and curing, finishing etc. complete with initial lift of 1.50m below / above ground level. P.C.C. 1:3:6

1.75

-

6274.4

... More
Providing and casting in situ C.C. of trap/ granite/ quartzite/ gneiss metal of approved quality for RCC work as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, from work, compaction, finishing the formed surface with CM 1:3 of sufficient minimum thickness to necessary or roughening if special finish is tobe provided and curing etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use for L&T, ACC, Ambuja, Birla Gold, Manikgad, Rajashree etc. cement is permitted excluding M.S. or Tor reinforcement)For RCC M-200 grade slabs / Landings / Vertical Walls/ Waist Slabs / Steps for Staircase. RCC M-200 A) R.C.C. Footing

0.24

-

8049.8

... More
B)R.C.C. Column

1.15

-

9696.5

... More
C)R.C.C. Beam

3.56

-

9541.4

... More
D)Chajja

0.16

-

10200.3

... More
E)R.C.C. Slab

1.7

-

10244.3

... More
Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundation, slabs, beams, columns, canopies, staircases. newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete. (including cost of binding wire)

0.32

-

98145

... More
Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete

10.57

-

8793.4

... More
Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 mm with lock plate of 3.15 mm thickness reinforced with 35 x 35 x 5 mm angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65 mm and 3.15 mm respectively with hold fast arrangements, M.S. Bracket plate 300 x 300 x 3.15 mm minimum size and shape with square bar, suspension shaft of minimum 32 mm diameter, hood cover of M.S. sheet not less than 0.9 mm thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc. complete. (I.S. 62481979) (Without mechanical gear)

1.62

-

5311.9

... More
Providing and fixing steel window of various sizes as per detailed drawing without hot dip zinc coating, without ventilators, including fabricating / glazing with plain / obscured glass panels of approved type and quality, iron oxidised fixtures and fastenings, finishing with oil painting two coats complete (with guard bars 12 mm square at 10 cm c/c.)

0.54

-

5361.4

... More
Providing internal cement plaster 20mm. thick in Single coats in cement mortar 1:3 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete.

43.92

-

432.3

... More
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete.

62.71

-

702.9

... More
Providing and laying cement concrete flooring 50 mm thick with M15 cement concrete laid to proper level and slope in alternate bays including compaction filling joints, marking lines to give the appearance of tiles of 30cm x 30cm or other size laid diagonally/ square etc finishing smooth (with extra cement) in any colour as directed and curing etc. complete.with Crushed sand VSI Grade

9

-

639.1

... More
Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces. (excluding the primer coat.) etc. complete.

43.92

-

52.8

... More
Providing and applying white-wash in two coats on old / new plastered or masonry surfaces and asbestos cement sheets including scaffolding and preparing the surface by brushing and brooming down etc. complete.

9

-

13.2

... More
Providing and applying two coats of exterior acraylic emulsion paint confirming to corresponding I.S. of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface, applying primer coat ,scaffolding if necessary , and watering the surface for two days etc complete.

62.71

-

287.1

... More
Providing internal & external electrification of switch room including cost of all material & labour shown in rate analysis etc. complete.

2

-

2000

... More
S.W. No. 03:- Pur Water Pumping Machinery (15 HP 1W +1S)- Providing, errecting and giving test of submersible Pump set confirming to I.S. 8034 and motor confirming to I.S. 9283 with water proof wiring, pump shall be suitable for 64m delivery head and discharge of 4.90 LPS with stainless steel shaft, motor suitable for working 415V(+/-) 10%, 3 Phase, 50 Hz AC supply with cable guard, thrust carbon bearing to withstand entire hydraulic thrust. The pump shall be suitable for direct coupling with suitable suction, straining pump should have suitable discharge outlet as per manufacturers design. Stream lined non return valve shall be provided with pump, 3m submersible copper conductor cable and 2 pair of erection clamps, 65mm width, 150mm Dia thick shall be provided with each pump. 15 HP Submerssible Pumpset,18550 LPH Discharge, 107 Head in M. 200 MM Dia.

2

-

95715.42

... More
Providing ISI mark G.I. pipe of following class and dia.excluding GST levied by GOI and GOM in all respect including inspection charges, transportation to stores, etc. complete as per IS-1239/2004. 65 mm Dia. G.I. Pipe (B Class )

80

-

504

... More
Providing & fixing of M.S. clamps for holding 65mm dia G.I. pipe.

4

-

800

... More
3 core PVC insulated, PVC sheathed copperconductor flat submersible cable Supplying and erecting, Flat flexible submersible cable with, Copper Conductor, PVC insulated, and PVC sheathed. (3 core 10 sq mm)

80

-

429

... More
Supplying & erecting G.I. pipe ‘A’ class 25 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE 25 MM Dia G.I.Pipe

80

-

196

... More
Making trench in soft soil of suitable width & depth for laying provided L.T cable up to 10 sq.mm complete.As per specification No. CW-EXN-CTR

80

-

167.3

... More
supplying and erecting DOL starter to operate squirrel cage induction motor working on 380- 440 Volt, 3 phase, 50 Hz with no volt coil and over load element with necessary material and connected to supply, etc complete. Starter with original sheet steel encloser. 15 HP Pump

1

-

18475.68

... More
Providing tools for pumping machinary

1

-

6802

... More
Aluminium conductor 4 Core, XLPE / PVC insulated & armoured cable Supplying and erecting, XLPE / PVC insulated, annoured cable 1100 V grade with ISi mark Four core, solid/ stranded aluminium conductor with 6 mm thick 25 mm width M.S. spacer with G.I. Earth wire 6 sq mm, complete erected on wall / on pole with 25 X 3 mm M.S. clamps or in provided trench in an approved manner.

60

-

266.2

... More
Providing and supplying ISI standard CI flanged / S& S specials excluding GST levied by GOI & GOM in all respect including railway freight, insurance, unloading from railway wagon, loading into truck transport to departmental store, unloading stacking etc. complete.

40

-

73

... More
EARTHING Supplying & errecting galvanised cast iron earth plate size 60 x 60 x .6 cm complete with all materials , testing as per specification No.EA-EP

2

-

5186

... More
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.

20

-

244.2

... More
Providing & fixing 100 mm dia. Pressure gauge.

2

-

929.16

... More
Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete

2

-

5132

... More
Providing , installing 80 MM. dia. Reflux Valve PN-1 rating, water works quality without bypass arrangements etc.complete.(MJP SSR 21-22,P.No. 131/1,4,5)

2

-

4092

... More
Supplying, installing, testing & commissioning 3 phase, 11/0.433 kV, 50 Hz., 25kVA Mineral oil immersed and naturally cooled outdoor type, aluminium wound Non-sealed transformer, delta/star connected with additional neutralbrought out on load side, temperature rise should not exceed 40 ℃ bythermometer in oil and 45 ℃ by the resistance method in winding at full loadrating, using type A winding insulation (kraft paper) with standard accessoriescomplete with test certificate with losses below 190 Watts at 50% load, 635Watts at 100% load as per IS:1180 (part 1) : 2014 with necessary permissions ofElectrical Inspector, asper specification no SS- TR-NSL.

1

-

91866

... More
Supplying & erecting inline D.P. Structure for 11/0.415kV, 63kVA Transformer with RSJ pole 2 nos. of size 100x116mm x 11m long with suitabledistribution box of CRCA sheet 16 SWG with 4 pole MCCB 100A as incomer & 6 nos. 63A kitkat/MCCB for outing circuits. Transformer D.P. Structure includes the A.B. switch 200A, D.O. fuse set & L.A. set. 2 nos. top channel of size 100x50mm for erection of A.B. Switch & 2 nos. base channel of size 100x50mm for erecting Transformer channel of size 75x40mm for erecting D.O. fuse set, L.A., A.B. switch handle etc. Angle of size 50x50x6mm for erecting distribution box, Transformer belt etc. as per drawing (min. 124 Kg. iron work ) with necessary clamps, Nut-bolts. V cross arm, top clip, insulators etc. with caution board &barbed wire, D.P. structure shall be erected in c.c. foundation complete.

1

-

127893

... More
Rising Main HDPE 12.5 Kg 125 mm L = 8065m- Providing and supplying in standard lengths Polyethelene Pipes, confirming to IS 4984 / 14151 / 12786 / 13488 with nesessary jointing material like mechanical connector i. e. thread / insert joint / quick release coupler joint / compression fitting joint or flanged joint excluding coupler/specials, includingb transportation and freight charges, inspection charges, loading / unloading charges, conveyance to the departmental stores & stacking the same in closed shade duly protecting from sunrays & rains, excluding GST levied by GI & GOM in all respect etc. complete. 125 mm dia HDPE 12.5 kg

8065

-

874

... More
Providing & supplying HDPE/GI specials ( 5 % of cost of pipe shall be considered percent of specials for estimate purpose.)

1

-

352440.5

... More
Providing double flange sluice valve confirming for IS-14846 including worn gear arrangements as per test pressure,stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. As Sluice Valve/Scour valve -150mm dia. Sluice Valve

12

-

10795

... More
Providing and Fixing ISI mark CI D/F reflux valves (non-return valves ) of following dia including railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental stores, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete.Reflux valves as per I.S.5312 Part I (1984) As Non Return Valve- 150 mm dia. Sluice Valve

7

-

9876

... More
Providing and supplying Air Valves as per IS-14845-2000 and MJP’s standard specifications of approved make and quality of following diameters including railway freight, inspection charges, unloading from railway wagons, loading into truck, transportation upto departmental stores, unloding and stacking excluding GST levied by GOI & GOM in all respect etc. complete. 25 mm dia. Single Ball Air Valve

27

-

1054

... More
Excavation for foundation / Pipe Trenches in earth soil of all types, sand, gravel and soft murum including removing the excavated material upto a distance of 50mtrs. And lift as below stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding back filling etc. complete.

1512.19

-

165

... More
Excavation for foundation / pipe trenches in hard murum with boulders, WBM roads including removing the excavated material upto a distance of 50 meters beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding back filling etc. complete.

1814.63

-

211.2

... More
Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation, asphalt roadincluding removing the excavated material upto a distance of 50 meters beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding back filling etc. complete.

1512.19

-

629.2

... More
Excavation for foundation / pipe trenches in hard rock by controlled blasting, including trimming and levelling the bed by chiselling where necessary and removing the excavated material and stacking it in measurable heaps within a distance of 50 metres from the area and lifts as below, normal dewatering, excluding backfilling, etc. complete.

1512.19

-

830.5

... More
Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard murum material in 15cm layers with all leads and lifts including consolidation, surcharging etc. complete.

907.31

-

92.4

... More
Lowering, Laying and Jointing H. D. P. E./M D. P. E. pipes in proper position including all specials by compression fitting/electrofusion and butt fusion jointing procedure as per relevent IS Code complete with all materials for jointing procedure like Electrofusion machine, Electric heater/butt fusion welding machine with hydraulicjack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part II 125mm dia H.D.P.E 10 Kg/cm2 pipe

8065

-

88

... More
Lowering, laying and jointing Valves and specials of following class and diameter including conveyance from stores to site of works, all labour, giving satisfactory hydraulic test etc complete either underground or in vertical position as directed by Engineer-in-charge As Sluice Valve/Scour valve- 150 mm dia. Sluice Valve

19

-

3927

... More
Providing and laying in situ 1:2:4 (M-150) grade of C.C. of trap / granite/ quartzite/ gneiss metal for foundation and bedding including dewatering, form work, compacting and curing finishing etc complete with initial lift of 1.50m below /above ground level.

270

-

6824.4

... More
Providing and fixing in position air valve shaft including providing and fixing GI Medium class or 6mm thick M.S, PIPE shaft 2.70m long over branch flange of air valve tee providing PCCblock of M- 150concrete 150mm thick around the air valve tee including encasing of vertical shaft in PCC M-150 as shown in type design together with providing and making flanged ionts wherver required and fixing of air valve over the shaft excluding cost of air vavle and branch flanged air valve tee, etc. complete as per type desihn and as per directed by Engineer - in -charge for following diameters of pipe line Foundation on Murum and Harder Strata.- 25 mm dia. Single Ball Air Valve

27

-

6135.8

... More
Providing & costructing B.B masonry valve chamber with 15 cm thick 1: 3 :6 proportion PCC bedding ,excluding excavation ,B.B masonry in C.M 1:5 proportion precast RCC frame and cover etc. complete as directed by Engineer-in-charge Chamber size 60X45X90cm

19

-

7254.5

... More
Hydraulic testing of H. D. P. E./ M. D. P. E. pipe line to specified pressure including cost of all materials and labour and water for testing for specified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position.. 125 mm dia HDPE 12.5 Kg/cm2 pipe

8.07

-

9550.2

... More
Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard murum material in 15cm layers with all leads and lifts including consolidation, surcharging etc. complete.

6029.92

-

92.4

... More
RCC ESR Capacity of 60000 Liters, for 9 Meter Staging TITANE- Designing (aesthetically) and constructing RCC elevated service reservoirs of following capacity with RCC staging consisting of columns, internal and external bracings spaced vertically not more than 4.5M. Centre to centre for ESR having capacity upto 500cum and not more than 6 m. c/c for ESRs having capacity above 500 cum including excavation in all types of strata, foundation concrete, cement plaster with water proofing compound to the inside face of the container including refilling disposing of the surplus stuff within a lead of 50 M. all labour and material charges including lowering, laying, erecting,, hoisting and jointing of pipe assembly of inlet, outlet, washout, overflow and bypass arrangements as per departmental desing, providing and fixing accessories such as M.S. ladder, C.I. manhole frame and covers water level indicatiors, lightening conductor, G.I. pipe railing around walk

1

-

1684620.72

... More
Providing and supplying ISI standard welded CI double flanged pipes excluding GST levied by GOI & GOM in all respect including railway freight, insurance, unloading from railway wagon, loading into truck transport to stores unloading etc. complete as directed by Engineer-in-charge., Inlet Pipe- 100 mm dia CIDF pipes

48

-

2738

... More
Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure,stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. c) Sluice valve - PN - 1 (Without by pass arrangement) 100 mm dia CIDF Sluice Valve

3

-

6835

... More
Providing and supplying ISI standard CI flanged / S& S specials excluding GST levied by GOI & GOM in all respect including railway freight, insurance, unloading from railway wagon, loading into truck transport to departmental store, unloading stacking etc. complete. Diameter 80 mm to 300 mm

250

-

73

... More
Distribution System (75 mm = 2046 m, 90 mm = 264 m, 110 mm =234 m, 140mm=12m PVC 4KG Total Length =2.556 Km- Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification no. 4985 / 1988 excluding GST levied by GOI and GOM in all respect, including transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solvent cement, etc. complete (selffit type to be jointed with cement solvent).75 mm dia pvc 4 kg/cm2

2046

-

115

... More
90 mm dia pvc 4 kg/cm2

264

-

160

... More
110 mm dia pvc 4 kg/cm2

234

-

219

... More
140 mm dia pvc 4 kg/cm2

12

-

367

... More
Providing double flange sluice valve confirming for IS-14846 including worn gear arrangements as per test pressure,stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. 80mm dia CIDF Sluice valve 80 mm dia CIDF Sluice valve

8

-

5132

... More
100 mm dia CIDF Sluice valve

1

-

6835

... More
150 mm dia CIDF Sluice valve

1

-

10251

... More
Providing and supplying PVC/C.I/G.I. Specials. '( 10% of pipes cost)

1

-

33318

... More
Excavation for foundation / Pipe Trenches in earth soil of all types, sand, gravel and soft murum including removing the excavated material upto a distance of 50mtrs. And lift as below stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding back filling etc. complete. 0.0 to 1.50.

779.1

-

165

... More
Excavation for foundation / pipe trenches in hard murum with boulders, WBM roads including removing the excavated material upto a distance of 50 meters beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding back filling etc. complete.

701.19

-

211.2

... More
Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation, asphalt roadincluding removing the excavated material upto a distance of 50 meters beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding back filling etc. complete.

233.73

-

629.2

... More
Lowerig and laying and jointing with PVC pipes and specials of following class and diameter including cost of conveyance from stores to site of works including cost of all labour, material except cement solvent, rubber ring giving satisfactory hydraullic testing as per IS Code etc complete (with cement sovlentjoint / ring fit joint working pressure 4 Kg./Sqm.) 75 mm dia pvc 4 kg/cm2

2046

-

27.5

... More
90 mm dia pvc 4 kg/cm2

264

-

34.1

... More
110 mm dia pvc 4 kg/cm2

234

-

38.5

... More
140 mm dia pvc 4 kg/cm2

12

-

45.1

... More
Hydraulic testing of PVC pipe line to specified pressure including cost of all materials and labour and water for testing for specified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position. 75 mm dia pvc 4 kg/cm2

2.05

-

2729.1

... More
90 mm dia pvc 4 kg/cm2

0.26

-

4093.1

... More
110 mm dia pvc 4 kg/cm2

0.23

-

4093.1

... More
140 mm dia pvc 4 kg/cm2

0.01

-

5437.1

... More
Lowering, laying and jointing Valves and specials of following class and diameter including conveyance from stores to site of works, all labour, giving satisfactory hydraulic test etc complete either underground or in vertical position as directed by Engineer-in-charge . 80mm dia CIDF Sluice valve

8

-

1911.8

... More
100 mm dia CIDF Sluice valve

1

-

2499.2

... More
150 mm dia CIDF Sluice valve

1

-

3927

... More
Providing & costructing B.B masonry valve chamber with 15 cm thick 1: 3 :6 proportion PCC bedding ,excluding excavation ,B.B masonry in C.M 1:5 proportion precast RCC frame and cover etc. complete as directed by Engineer-in-charge Chamber size 60X45X90cm

10

-

7254.5

... More
Refilling the trenches with available excavated stuff with soft material first over pipelines and then hard material in 15cm layers with all leads and lifts including consolidation surcharging etc complete.

1461.69

-

92.4

... More
Providing and laying in situ 1:2:4(M-150) grade of C.C. of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including dewatering from work, compacting and curing, finishing etc. complete with initial lift of 1.50m below / above ground level.

9

-

6824.4

... More
Filling in plinth and floors murum bedding in trenches with approved murum from excavated materials from foundation 15cm to 20cm layers including watering and compaction, etc complete. (Bd-A-10/263)

230.22

-

92.4

... More
Solar Plant 65 kWp Capacity at Source.& WTP- Supplying, installing, testing and commissioning of 55 kWp capacity on grid solar power pack with GI mounting structure and inter connecting wires / cables without battery bank SPV modules and solar power conditioning unit of required capacity complete, with 5 years on site performance warrantee. Specification no. ESD-RTONG Note:Rates are as per benchmark cost of Ministry of New and Renewable Energy (MNRE), inclusive of total system cost including PV solar module ,invertor,balance of systems including cables,switces/circuit breakers/connectors/junction boxes,mounting structure,earthing,lightning arrestors,cost of meter(if any other than net meter),local connectivity cost,cost of civil works,foundation etc and it's installation, commissioning, transportation, insurance,capital cost of online monitoring, comprehensive maintenance charges for five years,applicable fees and taxes etc..

10

-

38236

... More
Supplying and erecting AC three phase LT CT multifunction net meter DLMS compliance of accuracy class 0.5, 3 x 240V, 50Hz, with backlit LCD display, optical port & RS 232 port (measures import kWh, kVAh, export kWh, kVAh, Net kWh, kVAh, V, I, kW, 6 months history of energy, load survey,TOD, tamper detection & logging, power ON/OFF events, instantaneous parameters of rating 1/5A with display in absence of power) with wiring connections and mounting hardware on provided panels complete with calibration certificate from manufacturer.

2

-

16282.2

... More
AMBEMOHAR- Rising Main HDPE 12.5 Kg 90 mm L = 1637m- Providing and supplying in standard lengths Polyethelene Pipes, confirming to IS 4984 / 14151 / 12786 / 13488 with nesessary jointing material like mechanical connector i. e. thread / insert joint / quick release coupler joint / compression fitting joint or flanged joint excluding coupler/specials, includingb transportation and freight charges, inspection charges, loading / unloading charges, conveyance to the departmental stores & stacking the same in closed shade duly protecting from sunrays & rains, excluding GST levied by GI & GOM in all respect etc. complete. 90 mm dia HDPE 12.5 kg

1637

-

460

... More
Providing & supplying HDPE/GI specials ( 5 % of cost of pipe shall be considered percent of specials for estimate purpose.)

1

-

11901

... More
Providing double flange sluice valve confirming for IS-14846 including worn gear arrangements as per test pressure,stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. As Sluice Valve/Scour valve -80mm dia. Sluice Valve

3

-

5132

... More
Providing and Fixing ISI mark CI D/F reflux valves (non-return valves ) of following dia including railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental stores, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete.Reflux valves as per I.S.5312 Part I (1984) As Non Return Valve- 80 mm dia. Sluice Valve

2

-

4092

... More
Providing and supplying Air Valves as per IS-14845-2000 and MJP’s standard specifications of approved make and quality of following diameters including railway freight, inspection charges, unloading from railway wagons, loading into truck, transportation upto departmental stores, unloding and stacking excluding GST levied by GOI & GOM in all respect etc. complete. 20 mm dia. Single Ball Air Valve

7

-

764

... More
Excavation for foundation / Pipe Trenches in earth soil of all types, sand, gravel and soft murum including removing the excavated material upto a distance of 50mtrs. And lift as below stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding back filling etc. complete.

294.66

-

165

... More
Excavation for foundation / pipe trenches in hard murum with boulders, WBM roads including removing the excavated material upto a distance of 50 meters beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding back filling etc. complete.

294.66

-

211.2

... More
Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation, asphalt roadincluding removing the excavated material upto a distance of 50 meters beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding back filling etc. complete.

245.55

-

629.2

... More
Excavation for foundation / pipe trenches in hard rock by controlled blasting, including trimming and levelling the bed by chiselling where necessary and removing the excavated material and stacking it in measurable heaps within a distance of 50 metres from the area and lifts as below, normal dewatering, excluding backfilling, etc. complete.

147.33

-

830.5

... More
Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard murum material in 15cm layers with all leads and lifts including consolidation, surcharging etc. complete.

147.33

-

92.4

... More
Lowering, Laying and Jointing H. D. P. E./M D. P. E. pipes in proper position including all specials by compression fitting/electrofusion and butt fusion jointing procedure as per relevent IS Code complete with all materials for jointing procedure like Electrofusion machine, Electric heater/butt fusion welding machine with hydraulicjack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part II 90 mm dia H.D.P.E 12.5 Kg/cm2 pipe

1637

-

73.7

... More
Lowering, laying and jointing Valves and specials of following class and diameter including conveyance from stores to site of works, all labour, giving satisfactory hydraulic test etc complete either underground or in vertical position as directed by Engineer-in-charge As Sluice Valve/Scour valve- 80 mm dia. Sluice Valve

5

-

1911.8

... More
Providing and laying in situ 1:2:4 (M-150) grade of C.C. of trap / granite/ quartzite/ gneiss metal for foundation and bedding including dewatering, form work, compacting and curing finishing etc complete with initial lift of 1.50m below /above ground level.

45

-

6824.4

... More
Providing and fixing in position air valve shaft including providing and fixing GI Medium class or 6mm thick M.S, PIPE shaft 2.70m long over branch flange of air valve tee providing PCCblock of M- 150concrete 150mm thick around the air valve tee including encasing of vertical shaft in PCC M-150 as shown in type design together with providing and making flanged ionts wherver required and fixing of air valve over the shaft excluding cost of air vavle and branch flanged air valve tee, etc. complete as per type desihn and as per directed by Engineer - in -charge for following diameters of pipe line Foundation on Murum and Harder Strata.- 20 mm dia. Single Ball Air Valve

7

-

6135.8

... More
Providing & costructing B.B masonry valve chamber with 15 cm thick 1: 3 :6 proportion PCC bedding ,excluding excavation ,B.B masonry in C.M 1:5 proportion precast RCC frame and cover etc. complete as directed by Engineer-in-charge Chamber size 60X45X90cm

5

-

7254.5

... More
Hydraulic testing of H. D. P. E./ M. D. P. E. pipe line to specified pressure including cost of all materials and labour and water for testing for specified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position.. 90 mm dia HDPE 12.5 Kg/cm2 pipe

1.64

-

8186.2

... More
Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard murum material in 15cm layers with all leads and lifts including consolidation, surcharging etc. complete.

926.79

-

92.4

... More
Distribution System (75 mm = 900 m, Total Length =0.9 Km- Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification no. 4985 / 1988 excluding GST levied by GOI and GOM in all respect, including transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solvent cement, etc. complete (selffit type to be jointed with cement solvent).75 mm dia pvc 4 kg/cm2

900

-

115

... More
Providing double flange sluice valve confirming for IS-14846 including worn gear arrangements as per test pressure,stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. 80mm dia CIDF Sluice valve 80 mm dia CIDF Sluice valve

5

-

5132

... More
Providing and supplying PVC/C.I/G.I. Specials. '( 10% of pipes cost)

1

-

10350

... More
Excavation for foundation / Pipe Trenches in earth soil of all types, sand, gravel and soft murum including removing the excavated material upto a distance of 50mtrs. And lift as below stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding back filling etc. complete. 0.0 to 1.50.

270

-

165

... More
Excavation for foundation / pipe trenches in hard murum with boulders, WBM roads including removing the excavated material upto a distance of 50 meters beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding back filling etc. complete.

243

-

211.2

... More
Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation, asphalt roadincluding removing the excavated material upto a distance of 50 meters beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding back filling etc. complete.

81

-

629.2

... More
Lowerig and laying and jointing with PVC pipes and specials of following class and diameter including cost of conveyance from stores to site of works including cost of all labour, material except cement solvent, rubber ring giving satisfactory hydraullic testing as per IS Code etc complete (with cement sovlentjoint / ring fit joint working pressure 4 Kg./Sqm.) 75 mm dia pvc 4 kg/cm2

900

-

27.5

... More
Hydraulic testing of PVC pipe line to specified pressure including cost of all materials and labour and water for testing for specified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position. 75 mm dia pvc 4 kg/cm2

0.9

-

2729.1

... More
Lowering, laying and jointing Valves and specials of following class and diameter including conveyance from stores to site of works, all labour, giving satisfactory hydraulic test etc complete either underground or in vertical position as directed by Engineer-in-charge . 80mm dia CIDF Sluice valve

5

-

1911.8

... More
Providing & costructing B.B masonry valve chamber with 15 cm thick 1: 3 :6 proportion PCC bedding ,excluding excavation ,B.B masonry in C.M 1:5 proportion precast RCC frame and cover etc. complete as directed by Engineer-in-charge Chamber size 60X45X90cm

5

-

7254.5

... More
Refilling the trenches with available excavated stuff with soft material first over pipelines and then hard material in 15cm layers with all leads and lifts including consolidation surcharging etc complete.

500.93

-

92.4

... More
Providing and laying in situ 1:2:4(M-150) grade of C.C. of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including dewatering from work, compacting and curing, finishing etc. complete with initial lift of 1.50m below / above ground level.

8.1

-

6824.4

... More
Filling in plinth and floors murum bedding in trenches with approved murum from excavated materials from foundation 15cm to 20cm layers including watering and compaction, etc complete. (Bd-A-10/263)

81

-

92.4

... More
INDIRANAGAR- Rising Main HDPE 10 Kg 90 mm L = 475m- Providing and supplying in standard lengths Polyethelene Pipes, confirming to IS 4984 / 14151 / 12786 / 13488 with nesessary jointing material like mechanical connector i. e. thread / insert joint / quick release coupler joint / compression fitting joint or flanged joint excluding coupler/specials, includingb transportation and freight charges, inspection charges, loading / unloading charges, conveyance to the departmental stores & stacking the same in closed shade duly protecting from sunrays & rains, excluding GST levied by GI & GOM in all respect etc. complete. 90 mm dia HDPE 10 kg

475

-

389

... More
Providing & supplying HDPE/GI specials ( 5 % of cost of pipe shall be considered percent of specials for estimate purpose.)

1

-

9238.75

... More
Providing double flange sluice valve confirming for IS-14846 including worn gear arrangements as per test pressure,stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. As Sluice Valve/Scour valve -80mm dia. Sluice Valve

2

-

5132

... More
Providing and Fixing ISI mark CI D/F reflux valves (non-return valves ) of following dia including railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental stores, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete.Reflux valves as per I.S.5312 Part I (1984) As Non Return Valve- 80 mm dia. Sluice Valve

1

-

4092

... More
Providing and supplying Air Valves as per IS-14845-2000 and MJP’s standard specifications of approved make and quality of following diameters including railway freight, inspection charges, unloading from railway wagons, loading into truck, transportation upto departmental stores, unloding and stacking excluding GST levied by GOI & GOM in all respect etc. complete. 20 mm dia. Single Ball Air Valve

2

-

764

... More
Excavation for foundation / Pipe Trenches in earth soil of all types, sand, gravel and soft murum including removing the excavated material upto a distance of 50mtrs. And lift as below stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding back filling etc. complete.

85.5

-

165

... More
Excavation for foundation / pipe trenches in hard murum with boulders, WBM roads including removing the excavated material upto a distance of 50 meters beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding back filling etc. complete.

85.5

-

211.2

... More
Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation, asphalt roadincluding removing the excavated material upto a distance of 50 meters beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding back filling etc. complete.

71.25

-

629.2

... More
Excavation for foundation / pipe trenches in hard rock by controlled blasting, including trimming and levelling the bed by chiselling where necessary and removing the excavated material and stacking it in measurable heaps within a distance of 50 metres from the area and lifts as below, normal dewatering, excluding backfilling, etc. complete.

42.75

-

830.5

... More
Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard murum material in 15cm layers with all leads and lifts including consolidation, surcharging etc. complete.

42.75

-

92.4

... More
Lowering, Laying and Jointing H. D. P. E./M D. P. E. pipes in proper position including all specials by compression fitting/electrofusion and butt fusion jointing procedure as per relevent IS Code complete with all materials for jointing procedure like Electrofusion machine, Electric heater/butt fusion welding machine with hydraulicjack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part II 90 mm dia H.D.P.E 6 Kg/cm2 pipe

475

-

34.1

... More
Lowering, laying and jointing Valves and specials of following class and diameter including conveyance from stores to site of works, all labour, giving satisfactory hydraulic test etc complete either underground or in vertical position as directed by Engineer-in-charge As Sluice Valve/Scour valve- 80 mm dia. Sluice Valve

3

-

1911.8

... More
Providing and laying in situ 1:2:4 (M-150) grade of C.C. of trap / granite/ quartzite/ gneiss metal for foundation and bedding including dewatering, form work, compacting and curing finishing etc complete with initial lift of 1.50m below /above ground level.

36

-

6824.4

... More
Providing and fixing in position air valve shaft including providing and fixing GI Medium class or 6mm thick M.S, PIPE shaft 2.70m long over branch flange of air valve tee providing PCCblock of M- 150concrete 150mm thick around the air valve tee including encasing of vertical shaft in PCC M-150 as shown in type design together with providing and making flanged ionts wherver required and fixing of air valve over the shaft excluding cost of air vavle and branch flanged air valve tee, etc. complete as per type desihn and as per directed by Engineer - in -charge for following diameters of pipe line Foundation on Murum and Harder Strata.- 20 mm dia. Single Ball Air Valve

2

-

6135.8

... More
Providing & costructing B.B masonry valve chamber with 15 cm thick 1: 3 :6 proportion PCC bedding ,excluding excavation ,B.B masonry in C.M 1:5 proportion precast RCC frame and cover etc. complete as directed by Engineer-in-charge Chamber size 60X45X90cm

3

-

7254.5

... More
Hydraulic testing of H. D. P. E./ M. D. P. E. pipe line to specified pressure including cost of all materials and labour and water for testing for specified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position.. 90 mm dia HDPE 6 Kg/cm2 pipe

0.48

-

5457.1

... More
Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard murum material in 15cm layers with all leads and lifts including consolidation, surcharging etc. complete.

203.23

-

92.4

... More
RCC ESR Capacity of 10000 Liters, for 9 Meter Staging INDIRANAGAR- Designing (aesthetically) and constructing RCC elevated service reservoirs of following capacity with RCC staging consisting of columns, internal and external bracings spaced vertically not more than 4.5M. Centre to centre for ESR having capacity upto 500cum and not more than 6 m. c/c for ESRs having capacity above 500 cum including excavation in all types of strata, foundation concrete, cement plaster with water proofing compound to the inside face of the container including refilling disposing of the surplus stuff within a lead of 50 M. all labour and material charges including lowering, laying, erecting,, hoisting and jointing of pipe assembly of inlet, outlet, washout, overflow and bypass arrangements as per departmental desing, providing and fixing accessories such as M.S. ladder, C.I. manhole frame and covers water level indicatiors, lightening conductor, G.I. pipe railing around walk

1

-

605200.2

... More
Providing and supplying ISI standard welded CI double flanged pipes excluding GST levied by GOI & GOM in all respect including railway freight, insurance, unloading from railway wagon, loading into truck transport to stores unloading etc. complete as directed by Engineer-in-charge., Inlet Pipe- 100 mm dia CIDF pipes

24

-

2738

... More
100 mm dia CIDF pipes

24

-

2738

... More
Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure,stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. c) Sluice valve - PN - 1 (Without by pass arrangement) 100 mm dia CIDF Sluice Valve

3

-

6835

... More
Providing and supplying ISI standard CI flanged / S& S specials excluding GST levied by GOI & GOM in all respect including railway freight, insurance, unloading from railway wagon, loading into truck transport to departmental store, unloading stacking etc. complete. Diameter 80 mm to 300 mm

440

-

73

... More
Distribution System (75 mm = 858 m, 90 mm =120 m, 110 mm =24 m, PVC 4KG Total Length = 1.002 Km- Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification no. 4985 / 1988 excluding GST levied by GOI and GOM in all respect, including transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solvent cement, etc. complete (selffit type to be jointed with cement solvent).75 mm dia pvc 4 kg/cm2

858

-

115

... More
90 mm dia pvc 4 kg/cm2

120

-

160

... More
110 mm dia pvc 4 kg/cm2

24

-

199

... More
Providing double flange sluice valve confirming for IS-14846 including worn gear arrangements as per test pressure,stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. 80mm dia CIDF Sluice valve 80 mm dia CIDF Sluice valve

5

-

5132

... More
100 mm dia CIDF Sluice valve

1

-

6835

... More
Providing and supplying PVC/C.I/G.I. Specials. '( 10% of pipes cost)

1

-

12264.6

... More
Excavation for foundation / Pipe Trenches in earth soil of all types, sand, gravel and soft murum including removing the excavated material upto a distance of 50mtrs. And lift as below stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding back filling etc. complete. 0.0 to 1.50.

270.54

-

165

... More
Excavation for foundation / pipe trenches in hard murum with boulders, WBM roads including removing the excavated material upto a distance of 50 meters beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding back filling etc. complete.

270.54

-

211.2

... More
Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation, asphalt roadincluding removing the excavated material upto a distance of 50 meters beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding back filling etc. complete.

92.34

-

629.2

... More
Excavation for foundation / pipe trenches in hard rock and concrete road by chiselling, wedging, line drilling, by machnial means or by any other means other than blasting including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, excluding backfilling, etc. complete.

4.32

-

1118.7

... More
Lowerig and laying and jointing with PVC pipes and specials of following class and diameter including cost of conveyance from stores to site of works including cost of all labour, material except cement solvent, rubber ring giving satisfactory hydraullic testing as per IS Code etc complete (with cement sovlentjoint / ring fit joint working pressure 4 Kg./Sqm.) 75 mm dia pvc 4 kg/cm2

858

-

27.5

... More
90 mm dia pvc 4 kg/cm2

120

-

34.1

... More
110 mm dia pvc 4 kg/cm2

24

-

38.5

... More
Hydraulic testing of PVC pipe line to specified pressure including cost of all materials and labour and water for testing for specified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position. 75 mm dia pvc 4 kg/cm2

0.86

-

2729.1

... More
90 mm dia pvc 4 kg/cm2

0.12

-

4093.1

... More
110 mm dia pvc 4 kg/cm2

0.02

-

4093.1

... More
Lowering, laying and jointing Valves and specials of following class and diameter including conveyance from stores to site of works, all labour, giving satisfactory hydraulic test etc complete either underground or in vertical position as directed by Engineer-in-charge . 80mm dia CIDF Sluice valve

5

-

1911.8

... More
100 mm dia CIDF Sluice valve

1

-

2499.2

... More
Providing & costructing B.B masonry valve chamber with 15 cm thick 1: 3 :6 proportion PCC bedding ,excluding excavation ,B.B masonry in C.M 1:5 proportion precast RCC frame and cover etc. complete as directed by Engineer-in-charge Chamber size 60X45X90cm

6

-

7254.5

... More
Refilling the trenches with available excavated stuff with soft material first over pipelines and then hard material in 15cm layers with all leads and lifts including consolidation surcharging etc complete.

530.78

-

92.4

... More
Providing and laying in situ 1:2:4(M-150) grade of C.C. of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including dewatering from work, compacting and curing, finishing etc. complete with initial lift of 1.50m below / above ground level.

12

-

6824.4

... More
Filling in plinth and floors murum bedding in trenches with approved murum from excavated materials from foundation 15cm to 20cm layers including watering and compaction, etc complete. (Bd-A-10/263)

90.18

-

92.4

... More
WASANTNAGAR- CONSTRUCTION OF NEW WELL FOR (6X15) Item No.1 : Taking Trial Bore (Core Bore Sampling) by Calyxe machine with TCT/NX bits together undisturbed strata samples for investigation in all types of strata soft soil, murum, hard murum with boulders, soft rock hard rock & quartizite etc. The item includes all Hire & running cost of Callyx Machine conveying all materials to site of work excluding conveyance of callyx, machine and back sampling all over burden strata in glass jar and core samples serially numbered at site in a wooden Core Box, Samples to be taken at 1.0 m interval and conveying to the place as directed by Engineer-in-charge, The diameter of bore in overburden shall be 100 mm and of NX size (50mm) in other strata. The item shall also include M.S. casing pipe of 2.5 mm thick plate in overburdern only and shall be 1.0 m above GL with cap over it. a) in over burden ( soft soil, murum)

6

-

1691.8

... More
b) in weathered rock/soft rock

12

-

3392.4

... More
Excavation in general in soft material comprising of soft soil, soft murum, sand, hard murum with boulders in wet or dry condition for Head Works i.e. Intake Well, Connecting Pipe, Jack Well, Pump House, Supply Well, etc. for lift 0 to 1.5 M and lead of 150 M including baricating, gurading, disposing off surplus excavated stuff within a radius of 0.5 km. as directed by Engineer-in- charge, etc. complete excluding refilling. Lift 0.00 to 1.50 M

95.38

-

334.4

... More
Lift 1.50 to 3.00 m

75.36

-

364.1

... More
Lift 3.00 to 4.50 m

66.23

-

393.8

... More
Lift 4.50 to 6.00 M.

57.7

-

423.5

... More
Excavation in general in hard material comprising of soft rock, hard rock, Manjara rock, etc, by blasting / controlled blasting, chiselling as required in wet or dry condition for Head Works i.e. Intake Well, Connecting Pipe, Jack Well, Pump House, supply Well, etc. for lift 0 to 1.5 M and lead of 150 M including baricading, guarding, disposing off surplus excavated stuff within a radius of 0.5 km. as directed by Engineer-in-charge, excluding refilling. Lift 6.0 to 7.50 M

42.39

-

900.9

... More
Lift 7.50 to 9.00 m

42.39

-

931.7

... More
Lift 9.00 to 10.50 m

42.39

-

962.5

... More
Lift 10.50 to 12.00 m

42.39

-

993.3

... More
Lift 12.0 to 13.50 m

42.39

-

1024.1

... More
Lift 13.50 to 15.00 m

42.39

-

1054.9

... More
Lift 15.00 to 16.00 m

28.26

-

1085.7

... More
Dewatering the excavated trenches and pools of water in the building trenches / pipeline trenches, well works by using pumps and other devices including disposing off water to safe distance as directed by Engineer-in-charge (including cost of machinery, labour, fuel), etc. complete.

1500

-

84.7

... More
Providing and laying in situ Cement concrete of trap/granite/quartzite/ gneiss metal for PCC work below foundation and footing including normal dewatering,plywood form work, compaction, finishing and curing, etc, complete.

6.99

-

6824.4

... More
Providing and casting in situ C. C. of trap/granite/quartzite/ gneiss metal of approved quality for RCC work as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, plywood form work,bully/steel prop ups, compaction, finishing the formed surfaces with CM 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finssh is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use fo L&T, A.C. C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted .) Excluding M.S.or Tor reinforcement a) R.C.C. Ring Beam ,M250

2.8

-

9541.4

... More
b) R.C.C. Ring Wall ,M200

27.27

-

10244.3

... More
Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundation, slabs, beams, columns, canopies, staircases. newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete.(including cost of binding wire) Tor Steel

2.1

-

98286.3

... More
Providing stuctural steel work in single stanchions composed of RSJ, channel, etc, with caps, bases, mild steel plates, angles, brackets, cleats, gusset plates, anchor bolts, etc. as per detailed design and drawing or as directed by Engineer-in-charge including cutting, fabrication, hoisting, erecting, fixing in position, making riveted/ bolted / welded connections and one coats of anticorrosive paint and over it two coats of oil painting, etc. complete.

0.31

-

77018.7

... More
Providing and fixing M.S. chaquerred plate flooring of following thickness supported on M.S.angles (25 x 25 x 8 mm size) including welding, cutting and fabricating the plate to the required square or rounding shape, making holes in the plate, including providing and applying 3 coats of anticorrosive paint, etc. complete as directed by Engineer-in-charge. 8mm Thick

12

-

5622.1

... More
Providing and filling around the well boulders filling of selected variety and size of boulders including cost of all materials, labour, transportation, etc. complete with all leads and lifts.

204.21

-

1071.4

... More
Providing and fixing in position C.I. Type dapuri steps of 22 mm dia. M.S. bar step with proper anchorage, etc. and providing and applying 3 coats of ant-corrosive paint, etc complete as directed by Engineer-in-charge.

14

-

425.7

... More
Providing, and fixing 80 mm dia A.C./P.V.C. pipe weep holes at 1.5 M c/c staggered including cost of all materials and labour involved with all leads and lifts.etc. complete with all leads and lifts.

12

-

221.1

... More
Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete.

287.91

-

92.4

... More
Drilling of horizontal bores in soft and hard strata 150mm dia.by D.T.C machine including transportation of machine at site.

120

-

405.9

... More
Carrying out recuperation / yeild test for ascerting the discharge of constructed well / excavated profile as direrted by Engineer in charge.The test carried out by drawing down water from the well/ profile below normal / subsoil water level upto full depth rise in water level is recorded. The normal water level / subsoil water level in the well / profile as well as strainer / suction level at pump as per design of W.S. scheme shall be recorded prior. to the test including cost of all materials. overhead, labours etc. completed as directed. The test shall be carried out as per technical circular No.2597 dt. 20/11/97 and shall be carried out for 7 days.

7

-

2383.7

... More
S.W. No. 02:-CONSTRUCTION OF SWITCH ROOM (3.0 X 3.0 X 3.0 M) Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means

3.76

-

165

... More
Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 cm to 20 cm thick including hand packing and compacting etc. complete.

2.35

-

1292.5

... More
Filling in plinth and floors / trenches with contractor’s murum for bedding in 15cm to 20cm layers including watering and compaction complete.

4.68

-

911.9

... More
Providing and laying in situ 1:3:6 (M-100) grade of C.C. of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including dewatering from work, compacting and curing, finishing etc. complete with initial lift of 1.50m below / above ground level. P.C.C. 1:3:6

1.75

-

6274.4

... More
Providing and casting in situ C.C. of trap/ granite/ quartzite/ gneiss metal of approved quality for RCC work as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, from work, compaction, finishing the formed surface with CM 1:3 of sufficient minimum thickness to necessary or roughening if special finish is tobe provided and curing etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use for L&T, ACC, Ambuja, Birla Gold, Manikgad, Rajashree etc. cement is permitted excluding M.S. or Tor reinforcement)For RCC M-200 grade slabs / Landings / Vertical Walls/ Waist Slabs / Steps for Staircase. RCC M-200 A) R.C.C. Footing

0.24

-

8049.8

... More
B)R.C.C. Column

1.15

-

9696.5

... More
C)R.C.C. Beam

3.56

-

9541.4

... More
D)Chajja

0.16

-

10200.3

... More
E)R.C.C. Slab

1.7

-

10244.3

... More
Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundation, slabs, beams, columns, canopies, staircases. newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete. (including cost of binding wire)

0.32

-

97206

... More
Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete

10.57

-

8793.4

... More
Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 mm with lock plate of 3.15 mm thickness reinforced with 35 x 35 x 5 mm angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65 mm and 3.15 mm respectively with hold fast arrangements, M.S. Bracket plate 300 x 300 x 3.15 mm minimum size and shape with square bar, suspension shaft of minimum 32 mm diameter, hood cover of M.S. sheet not less than 0.9 mm thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc. complete. (I.S. 62481979) (Without mechanical gear)

1.62

-

5311.9

... More
Providing and fixing steel window of various sizes as per detailed drawing without hot dip zinc coating, without ventilators, including fabricating / glazing with plain / obscured glass panels of approved type and quality, iron oxidised fixtures and fastenings, finishing with oil painting two coats complete (with guard bars 12 mm square at 10 cm c/c.)

0.54

-

5361.4

... More
Providing internal cement plaster 20mm. thick in Single coats in cement mortar 1:3 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete.

43.92

-

432.3

... More
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete.

62.71

-

702.9

... More
Providing and laying cement concrete flooring 50 mm thick with M15 cement concrete laid to proper level and slope in alternate bays including compaction filling joints, marking lines to give the appearance of tiles of 30cm x 30cm or other size laid diagonally/ square etc finishing smooth (with extra cement) in any colour as directed and curing etc. complete.with Crushed sand VSI Grade

9

-

639.1

... More
Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces. (excluding the primer coat.) etc. complete.

43.92

-

52.8

... More
Providing and applying white-wash in two coats on old / new plastered or masonry surfaces and asbestos cement sheets including scaffolding and preparing the surface by brushing and brooming down etc. complete.

9

-

13.2

... More
Providing and applying two coats of exterior acraylic emulsion paint confirming to corresponding I.S. of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface, applying primer coat ,scaffolding if necessary , and watering the surface for two days etc complete.

62.71

-

287.1

... More
Providing internal & external electrification of switch room including cost of all material & labour shown in rate analysis etc. complete.

2

-

2000

... More
S.W. No. 03:- Pur Water Pumping Machinery (2.5 HP 1W +1S)- Providing, errecting and giving test of submersible Pump set confirming to I.S. 8034 and motor confirming to I.S. 9283 with water proof wiring, pump shall be suitable for 64m delivery head and discharge of 4.90 LPS with stainless steel shaft, motor suitable for working 415V(+/-) 10%, 3 Phase, 50 Hz AC supply with cable guard, thrust carbon bearing to withstand entire hydraulic thrust. The pump shall be suitable for direct coupling with suitable suction, straining pump should have suitable discharge outlet as per manufacturers design. Stream lined non return valve shall be provided with pump, 3m submersible copper conductor cable and 2 pair of erection clamps, 65mm width, 150mm Dia thick shall be provided with each pump. 2.50 HP Submerssible Pumpset,2249 LPH Discharge, 94 Head in M. 200 MM Dia.

2

-

44413.5

... More
Providing ISI mark G.I. pipe of following class and dia.excluding GST levied by GOI and GOM in all respect including inspection charges, transportation to stores, etc. complete as per IS-1239/2004. 65 mm Dia. G.I. Pipe (B Class )

60

-

490

... More
Providing & fixing of M.S. clamps for holding 65mm dia G.I. pipe.

6

-

800

... More
3 core PVC insulated, PVC sheathed copperconductor flat submersible cable Supplying and erecting, Flat flexible submersible cable with, Copper Conductor, PVC insulated, and PVC sheathed. (3 core 10 sq mm)

60

-

152.9

... More
Supplying & erecting G.I. pipe ‘A’ class 25 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE 25 MM Dia G.I.Pipe

39.91

-

196

... More
Making trench in soft soil of suitable width & depth for laying provided L.T cable up to 10 sq.mm complete.As per specification No. CW-EXN-CTR

100

-

167.3

... More
supplying and erecting DOL starter to operate squirrel cage induction motor working on 380- 440 Volt, 3 phase, 50 Hz with no volt coil and over load element with necessary material and connected to supply, etc complete. Starter with original sheet steel encloser. 2.5 HP Pump

2

-

6669.3

... More
Providing tools for pumping machinary

1

-

6802

... More
Aluminium conductor 4 Core, XLPE / PVC insulated & armoured cable Supplying and erecting, XLPE / PVC insulated, annoured cable 1100 V grade with ISi mark Four core, solid/ stranded aluminium conductor with 6 mm thick 25 mm width M.S. spacer with G.I. Earth wire 6 sq mm, complete erected on wall / on pole with 25 X 3 mm M.S. clamps or in provided trench in an approved manner.

83

-

139

... More
Providing and supplying ISI standard CI flanged / S& S specials excluding GST levied by GOI & GOM in all respect including railway freight, insurance, unloading from railway wagon, loading into truck transport to departmental store, unloading stacking etc. complete.

100

-

95

... More
EARTHING Supplying & errecting galvanised cast iron earth plate size 60 x 60 x .6 cm complete with all materials , testing as per specification No.EA-EP

1

-

5185.4

... More
Providing & fixing 100 mm dia. Pressure gauge.

1

-

929.16

... More
Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete

2

-

6094

... More
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.

20

-

244.2

... More
Providing , installing 80 MM. dia. Reflux Valve PN-1 rating, water works quality without bypass arrangements etc.complete.(MJP SSR 21-22,P.No. 131/1,4,5)

2

-

4070

... More
WASANTNAGAR- Rising Main HDPE 10 Kg 90 mm L = 1783m- Providing and supplying in standard lengths Polyethelene Pipes, confirming to IS 4984 / 14151 / 12786 / 13488 with nesessary jointing material like mechanical connector i. e. thread / insert joint / quick release coupler joint / compression fitting joint or flanged joint excluding coupler/specials, includingb transportation and freight charges, inspection charges, loading / unloading charges, conveyance to the departmental stores & stacking the same in closed shade duly protecting from sunrays & rains, excluding GST levied by GI & GOM in all respect etc. complete. 90 mm dia HDPE 10 kg

1783

-

564

... More
Providing & supplying HDPE/GI specials ( 5 % of cost of pipe shall be considered percent of specials for estimate purpose.)

1

-

50280.6

... More
Providing double flange sluice valve confirming for IS-14846 including worn gear arrangements as per test pressure,stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. As Sluice Valve/Scour valve -80mm dia. Sluice Valve

3

-

5132

... More
Providing and Fixing ISI mark CI D/F reflux valves (non-return valves ) of following dia including railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental stores, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete.Reflux valves as per I.S.5312 Part I (1984) As Non Return Valve- 80 mm dia. Sluice Valve

2

-

4092

... More
Providing and supplying Air Valves as per IS-14845-2000 and MJP’s standard specifications of approved make and quality of following diameters including railway freight, inspection charges, unloading from railway wagons, loading into truck, transportation upto departmental stores, unloding and stacking excluding GST levied by GOI & GOM in all respect etc. complete. 20 mm dia. Single Ball Air Valve

8

-

764

... More
Excavation for foundation / Pipe Trenches in earth soil of all types, sand, gravel and soft murum including removing the excavated material upto a distance of 50mtrs. And lift as below stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding back filling etc. complete.

320.94

-

165

... More
Excavation for foundation / pipe trenches in hard murum with boulders, WBM roads including removing the excavated material upto a distance of 50 meters beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding back filling etc. complete.

320.94

-

211.2

... More
Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation, asphalt roadincluding removing the excavated material upto a distance of 50 meters beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding back filling etc. complete.

267.45

-

629.2

... More
Excavation for foundation / pipe trenches in hard rock by controlled blasting, including trimming and levelling the bed by chiselling where necessary and removing the excavated material and stacking it in measurable heaps within a distance of 50 metres from the area and lifts as below, normal dewatering, excluding backfilling, etc. complete.

160.47

-

830.5

... More
Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard murum material in 15cm layers with all leads and lifts including consolidation, surcharging etc. complete.

160.47

-

92.4

... More
Lowering, Laying and Jointing H. D. P. E./M D. P. E. pipes in proper position including all specials by compression fitting/electrofusion and butt fusion jointing procedure as per relevent IS Code complete with all materials for jointing procedure like Electrofusion machine, Electric heater/butt fusion welding machine with hydraulicjack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part II 90 mm dia H.D.P.E 8 Kg/cm2 pipe

1783

-

34.1

... More
Lowering, laying and jointing Valves and specials of following class and diameter including conveyance from stores to site of works, all labour, giving satisfactory hydraulic test etc complete either underground or in vertical position as directed by Engineer-in-charge As Sluice Valve/Scour valve- 80 mm dia. Sluice Valve

5

-

1911.8

... More
Providing and laying in situ 1:2:4 (M-150) grade of C.C. of trap / granite/ quartzite/ gneiss metal for foundation and bedding including dewatering, form work, compacting and curing finishing etc complete with initial lift of 1.50m below /above ground level.

3.6

-

6824.4

... More
Providing and fixing in position air valve shaft including providing and fixing GI Medium class or 6mm thick M.S, PIPE shaft 2.70m long over branch flange of air valve tee providing PCCblock of M- 150concrete 150mm thick around the air valve tee including encasing of vertical shaft in PCC M-150 as shown in type design together with providing and making flanged ionts wherver required and fixing of air valve over the shaft excluding cost of air vavle and branch flanged air valve tee, etc. complete as per type desihn and as per directed by Engineer - in -charge for following diameters of pipe line Foundation on Murum and Harder Strata.- 20 mm dia. Single Ball Air Valve

8

-

6135.8

... More
Providing & costructing B.B masonry valve chamber with 15 cm thick 1: 3 :6 proportion PCC bedding ,excluding excavation ,B.B masonry in C.M 1:5 proportion precast RCC frame and cover etc. complete as directed by Engineer-in-charge Chamber size 60X45X90cm

5

-

7254.5

... More
Hydraulic testing of H. D. P. E./ M. D. P. E. pipe line to specified pressure including cost of all materials and labour and water for testing for specified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position.. 90 mm dia HDPE 6 Kg/cm2 pipe

1.78

-

5457.1

... More
Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard murum material in 15cm layers with all leads and lifts including consolidation, surcharging etc. complete.

894.39

-

92.4

... More
Distribution System (75 mm = 216 m, 90 mm = 258 m, 110 mm =150 m, PVC 4KG Total Length = 0.624 Km- Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification no. 4985 / 1988 excluding GST levied by GOI and GOM in all respect, including transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solvent cement, etc. complete (selffit type to be jointed with cement solvent).75 mm dia pvc 4 kg/cm2

216

-

115

... More
90 mm dia pvc 4 kg/cm2

258

-

160

... More
110 mm dia pvc 4 kg/cm2

150

-

219

... More
Providing double flange sluice valve confirming for IS-14846 including worn gear arrangements as per test pressure,stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. 80mm dia CIDF Sluice valve 80 mm dia CIDF Sluice valve

4

-

5132

... More
100 mm dia CIDF Sluice valve

1

-

6835

... More
Providing and supplying PVC/C.I/G.I. Specials. '( 10% of pipes cost)

1

-

9897

... More
Excavation for foundation / Pipe Trenches in earth soil of all types, sand, gravel and soft murum including removing the excavated material upto a distance of 50mtrs. And lift as below stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding back filling etc. complete. 0.0 to 1.50.

175.23

-

165

... More
Excavation for foundation / pipe trenches in hard murum with boulders, WBM roads including removing the excavated material upto a distance of 50 meters beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding back filling etc. complete.

175.23

-

211.2

... More
Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation, asphalt roadincluding removing the excavated material upto a distance of 50 meters beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding back filling etc. complete.

58.41

-

629.2

... More
Lowerig and laying and jointing with PVC pipes and specials of following class and diameter including cost of conveyance from stores to site of works including cost of all labour, material except cement solvent, rubber ring giving satisfactory hydraullic testing as per IS Code etc complete (with cement sovlentjoint / ring fit joint working pressure 4 Kg./Sqm.) 75 mm dia pvc 4 kg/cm2

216

-

27.5

... More
90 mm dia pvc 4 kg/cm2

258

-

34.1

... More
110 mm dia pvc 4 kg/cm2

150

-

38.5

... More
Hydraulic testing of PVC pipe line to specified pressure including cost of all materials and labour and water for testing for specified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position. 75 mm dia pvc 4 kg/cm2

0.22

-

2729.1

... More
90 mm dia pvc 4 kg/cm2

0.26

-

4093.1

... More
110 mm dia pvc 4 kg/cm2

0.15

-

4093.1

... More
Lowering, laying and jointing Valves and specials of following class and diameter including conveyance from stores to site of works, all labour, giving satisfactory hydraulic test etc complete either underground or in vertical position as directed by Engineer-in-charge . 80mm dia CIDF Sluice valve

4

-

1911.8

... More
100 mm dia CIDF Sluice valve

1

-

2499.2

... More
Providing & costructing B.B masonry valve chamber with 15 cm thick 1: 3 :6 proportion PCC bedding ,excluding excavation ,B.B masonry in C.M 1:5 proportion precast RCC frame and cover etc. complete as directed by Engineer-in-charge Chamber size 60X45X90cm

5

-

7254.5

... More
Refilling the trenches with available excavated stuff with soft material first over pipelines and then hard material in 15cm layers with all leads and lifts including consolidation surcharging etc complete.

339.25

-

92.4

... More
Providing and laying in situ 1:2:4(M-150) grade of C.C. of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including dewatering from work, compacting and curing, finishing etc. complete with initial lift of 1.50m below / above ground level.

7.2

-

6824.4

... More
Filling in plinth and floors murum bedding in trenches with approved murum from excavated materials from foundation 15cm to 20cm layers including watering and compaction, etc complete. (Bd-A-10/263)

58.41

-

92.4

... More
Trial & Run of Scheme- Commissioning running and maintaining the scheme to quantities, rated capacity, including manning necessary personnel such as operator valveman, etc as per requirements of the scheme and who should also administer chemical dose for a period of 1 year together with training of personnel spared by MJP / local body and handing over the scheme to local body after completion of the above period as directed by Engineer-in-charge. For Single Village

1

-

26244

... More
b) TCL Requirement

1

-

1466

... More
c) MSEB Charges

1

-

71756



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.