Rural Development Department Tender
... More
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Rural Development Department - RDD Tender
Civil And Construction
Civil Works Others
Eprocure
Opening Date8 Feb 2025
Closing Date22 Feb 2025
Tender Amount₹ 39,74,186
Costs
EMD
₹ 39,800Document Cost
₹ 1,180Tender Fee
₹ 500
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_SATAR_1147398_3Tender No
No/Works/South/A-1/ET/70/2025Tender Authority
Rural Development Department ViewPurchaser Address
-Website
http://https://rdd.maharashtra.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Providing and laying in situ/Ready Mix cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete work in foundations like raft, strip foundations, grillage and footings of reinforced cement concrete columns and steel stanchions, excetra including bailling out water, formwork, cover blocks, compaction, curing and roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel), excetra complete, with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (using ARTIFICIAL SAND).
Item / Page No : 11 / 178
Specification No : Bd.F.3, B-7
Spec. Page No : 298, 38-40
Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
13.72
7348
100820.73
... More
Providing and laying in situ / ready mix M-20 cement concrete of trap / granite / quartzite / gneiss metal for cast in citu reinforced cement concrete solid piers, columns, excetra including provision of "V" shaped false joints to form suitable panels on the faces of approved design with compacting by vibrating and curing complete, including plywood / steel formwork, centering (excluding dewatering by means of pump) and including bailling out water and including finishing in cement mortar 1:3, curing complete.(With Concrete Mixer) With fine agreegates of required specifications (Natural sand / VSI sand finely washed excetra). (Height up to 5 metre) (using ARTIFICIAL SAND).
Item / Page No : 47 / 137
Specification No : MORTH 1700, 2204, 2304
Spec. Page No : ---
Additional Specifications : 1. With additional specifications for controlled conrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
10.21
8469
86474.11
... More
Providing and laying in situ / ready mix M-20 cement concrete of trap / granite / quartzite / gneiss metal for cast in citu reinforced cement concrete solid piers, columns, excetra including provision of "V" shaped false joints to form suitable panels on the faces of approved design with compacting by vibrating and curing complete, including plywood / steel formwork, centering (excluding dewatering by means of pump) and including bailling out water and including finishing in cement mortar 1:3, curing complete.(With Concrete Mixer) With fine agreegates of required specifications (Natural sand / VSI sand finely washed excetra). (Height up to 5 metre) (using ARTIFICIAL SAND).
Item / Page No : 47 / 137
Specification No : As per Item No 5a
Spec. Page No : ---
Additional Specifications : As per Item No 5a
6.16
8469
52172.43
... More
Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks,laying/pumping, compaction and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (using ARTIFICIAL SAND).
Item / Page No : 50 / 181
Specification No : Bd.F.6, B-7
Spec. Page No : 300-301, 38-40
Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
36.98
12513
462747.38
... More
Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks,laying/pumping, compaction and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (using ARTIFICIAL SAND).
Item / Page No : 50 / 181
Specification No : As per Item No 6a
Spec. Page No : ---
Additional Specifications : As per Item No 6a
26.68
12634
337097.8
... More
Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap/ granite / quartzite/ gneiss metal for reinforced cement concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks,laying / pumping, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (using ARTIFICIAL SAND).
Item / Page No : 70 / 182
Specification No : Bd.F.8, B-7
Spec. Page No : 302-303, 38-40
Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
16.32
14176
231359.66
... More
Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap/ granite / quartzite/ gneiss metal for reinforced cement concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks,laying / pumping, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (using ARTIFICIAL SAND).
Item / Page No : 70 / 182
Specification No : As per Item No 7a
Spec. Page No : ---
Additional Specifications : As per Item No 7a
13.86
14314
198398.97
... More
Providing and fixing in position thermo mechnically treated FE-500 steel bar reinforcement of various dias for reinforced cement concrete pile caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardis, copings, fins, arches, excetra as per detailed designs, drawings and schedules including cutting, bendding, hooking the bars, binding with wires or tack welding and supporting as requied complete.
Item / Page No : 33 / 188
Specification No : Bd.F.17
Spec. Page No : 306
6.66
89925
599171.27
... More
Providing and fixing in position thermo mechnically treated FE-500 steel bar reinforcement of various dias for reinforced cement concrete pile caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardis, copings, fins, arches, excetra as per detailed designs, drawings and schedules including cutting, bendding, hooking the bars, binding with wires or tack welding and supporting as requied complete.
Item / Page No : 33 / 188
Specification No : As per Item No 8a
Spec. Page No : ---
Additional Specifications : As per Item No 8a
4.31
90822
391534.5
... More
Filling in plinth and floors with approved excavated materials in 15 centimetre to 20 centimetre layers including watering and compacting, excetra complete.
Item / Page No : 36 / 157
Specification No : Bd.A.10
Spec. Page No : 262-263
10.75
120
1290
... More
Filling in plinth and floors with contractors material / brought from outside and approved by Engineer In-Charge, in 15 centimetre to 20 centimetre layers including watering and compaction, excetra complete.
Item / Page No : 37 / 157
Specification No : Bd.A.11
Spec. Page No : 263-264
57.85
802
46413.06
... More
Laboratory testing charges for various materials required for items of work, on the basis of testing frequency and charges fixed by Vigilence and Quality Control Circle, Pune.
Item / Page No : 4 / 0
Additional Specifications : 1. The amount of laboratory testing charges will be paid to contractor only after submission of the original receipt from the Vigillence and Quality Control Office with the name of work mensioned on it. 2. Above / below percentage quoted by the contractor will not be applicable for this item.Fineness Modulus (Sieve Analysis), Silt and Clay Content Test for Sand
1 Test per Source
1
30000
30000
... More
Providing second class burnt brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 in foundations and plinth of inner walls / in plinth of external walls including bailling out water manually, striking joints, on unexposed faces, racking out joints on exposed faces and watering, excetra complete. (using ARTIFICIAL SAND).
Item / Page No : 1 / 197
Specification No : Bd.G.1
Spec. Page No : 313
Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
10.94
8098
88596.5
... More
Providing second class burnt brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 in foundations and plinth of inner walls / in plinth of external walls including bailling out water manually, striking joints, on unexposed faces, racking out joints on exposed faces and watering, excetra complete. (using ARTIFICIAL SAND).
Item / Page No : 1 / 197
Specification No : As per Item No 12a
Spec. Page No : ---
Additional Specifications : As per Item No 12a
0.2
8098
1619.68
... More
Providing sand faced plaster externally in cement mortar using approved screened sand in all positions including base coat of 15 milimetre thick in cement mortar 1:4 using waterproofing compound at one killogramme per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment of 6 to 8 milimetre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days, scaffolding, excetra complete. (using ARTIFICIAL SAND).
Item / Page No : 11 / 209
Specification No : Bd.L.7
Spec. Page No : 369
Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
31.07
645
20061.9
... More
Providing sand faced plaster externally in cement mortar using approved screened sand in all positions including base coat of 15 milimetre thick in cement mortar 1:4 using waterproofing compound at one killogramme per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment of 6 to 8 milimetre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days, scaffolding, excetra complete. (using ARTIFICIAL SAND).
Item / Page No : 11 / 209
Specification No : As per Item No 13a
Spec. Page No : ---
Additional Specifications : As per Item No 13a
0.01
652
6.52
... More
Providing internal cement plaster 6 milimetre thick in a single coat in cement mortar 1:4 without neeru finish to concrete surface in all positions including scaffolding and curing, excetra complete. (using ARTIFICIAL SAND).
Item / Page No : 1 / 209
Specification No : Bd.L.1
Spec. Page No : 367
Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
134.39
204
27482.75
... More
Providing internal cement plaster 6 milimetre thick in a single coat in cement mortar 1:4 without neeru finish to concrete surface in all positions including scaffolding and curing, excetra complete. (using ARTIFICIAL SAND).
Item / Page No : 1 / 209
Specification No : As per Item No 14a
Spec. Page No : ---
Additional Specifications : As per Item No 14a
115.5
206
23850.75
... More
For Ground Floor
Item / Page No : 34 / 216
Specification No : Bd.M.3 B
Spec. Page No : 380
Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
127.93
4030
515628.26
... More
Providing and laying in position flooring of telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone of approved shade and size 18 milimetre to 20 milimetre thick on a bed of 1:6 cement mortar including cement float, striking joints, pointing in cement mortar 1:3, curing and cleaning, excetra complete. (using ARTIFICIAL SAND).
Item / Page No : 34 / 216
Specification No : As per Item No 15a
Spec. Page No : ---
Additional Specifications : As per Item No 15a
2.4
4030
9673.32
... More
For First Floor
Item / Page No : 34 / 216
Specification No : As per Item No 15a
Spec. Page No : ---
Additional Specifications : As per Item No 15a
109.04
4070
443880.03
... More
Providing and laying in position flooring of telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone of approved shade and size 18 milimetre to 20 milimetre thick on a bed of 1:6 cement mortar including cement float, striking joints, pointing in cement mortar 1:3, curing and cleaning, excetra complete. (using ARTIFICIAL SAND).
Item / Page No : 34 / 216
Specification No : As per Item No 15a
Spec. Page No : ---
Additional Specifications : As per Item No 15a
2.4
4070
9769.92
... More
Providing and applying two coats of exterior weather shield paint of approved manufacturer and of approved colour to the plastered surfaces including cleaning, preparing the plaster surfaces, applying primer coat, scaffolding, if necessary and watering the surface for two days, excetra complete.
Item / Page No : 26 / 225
Additional Specifications : The work shall be carried out as per instructions of Engineer in charge.
79.07
295
23325.65
... More
Providing and applying two coats of exterior weather shield paint of approved manufacturer and of approved colour to the plastered surfaces including cleaning, preparing the plaster surfaces, applying primer coat, scaffolding, if necessary and watering the surface for two days, excetra complete.
Item / Page No : 26 / 225
Specification No : As per Item No 16a
Spec. Page No : ---
Additional Specifications : As per Item No 16a
169.5
297
50502.53
... More
Providing and fixing heavy duty inter locking concrete rubber mould glossy paving blocks of 60 milimetre thickness of having a strength of 400 kilogram per square centimetre of approved quality and shape on a bed of crushed sand of 25 milimetre to 30 milimetre thick including striking joints and cleaning excetra complete.(using 100 per cent crushed sand), excetra complete.
Item / Page No : 53 / 219
Specification No : Bd.M-12
Spec. Page No : 385
Additional Specifications : The work shall be carried out as per instructions of Engineer in charge.
18
1162
20931.3
... More
Providing and laying Cast in situ / Ready Mix cement concrete M-15 of trap / granite / quartzite / gneiss metal for steps including steel centering, plywood / steel formwork, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing, excetra complete. The cement mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin, excetra (Wooden centering will not be allowed.) with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (using ARTIFICIAL SAND).
Item / Page No : 4 / 175
Specification No : Bd.E.2, B-7
Spec. Page No : 288, 38-40
Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
11.31
6604
74701.98
... More
Royalty charges for various building construction bonafied materials which are used for government bonafied works and for which Royalty charges are to be paid by the contractor. (This Item is to be paid to the contractor only after he pays the Royalty amount to Revenue department and produces the required voucher.)
Item / Page No : 3 / 0
Additional Specifications : 1. Government of Maharashtra, Revenue and Forest Department Gazette Number 146 Dated 04/06/2021 and Government of Maharashtra Public Works Department State Schedule of Rates 2021-22 General Note Number A(v), Page 5. 2. The amount of royalty charges will be paid only after submission of the receipt in original from Revenue authority for payment of royalty to Government, stating the name of work. 3. Above / below percentage quoted by the contractor will not be applicable for this item.
57.85
216
12506.01
... More
Providing and fixing Road junction / Information sign board of size 0.90 metre X 0.60 metre prepared on 16 gauge mild steel sheet with angle iron frame of size 35 milimetre X 35 milimetre X 5 milimetre including painting with one coat of zinc cromate stoving primer and two coats each of green/ white back ground and back side gray stove enamelled, bonded with red retro-reflective sheet Engineering grade, border / letters / numeral / arrows, coated with non pealable crystal clear protective coat retaining 100 percent reflection including two angle iron post of size 50 milimetre X 50 milimetre X 5 milimetre of 3.65 metre long inflated at bottom drilled on top and painted in white and black bands of 30 centimetre. with 4 numbers high strength galvanised iron bolts and nuts of size 10 milimetre diameter and 20 milimetre long sheet and angle iron post in one piece without joints including all taxes, conveying, fixing in ground with cement concrete 1:4:8 block of 60 centimetre X 60 centimetre X 75 centimetre size as directed by Engineer-in-charge, excetra complete. Mild Steel Board with Engineering Grade.
Item / Page No : 47 / 64
Specification No : MoRTH-801
Spec. Page No : ---
Additional Specifications : The work shall be carried out as per instructions of Engineer in charge.
1
7814
7814