Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Rural Development Department - RDD Tender

Works
Civil And Construction
Eprocure
Opening Date2 Dec 2022
Closing Date16 Dec 2022
Tender Amount₹ 1,34,38,211 
Notes
Download

Costs

Summary

Retrofiting Of Water Supply Scheme At Majrevadi Tal Shirol

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete.

15

-

157.5

... More
Filling in plinth and floors / trenches with contractor's murum for bedding in 15 cm to 20 cm layers including watering and compaction, etc. complete.

2.25

-

870.45

... More
Providing and supplying in standard lengths Polyethelene Pipes, confirming to IS 4984 /14151 / 12786 / 13488 with nesessary jointing material like mechanical connector i. e. thread /insert joint / quick release coupler joint /compression fitting joint or flanged joint excluding coupler/specials, including transportation and freight charges, inspection charges, loading / unloading charges, conveyance to the departmental stores & stacking the same in closed shade duly protecting from sunrays & rains, excluding GST levied by GI & GOM in all respect etc. complete. A.) PE-100 a) 6 Kg/Sq. cm : 160 mm dia

20

-

790

... More
Lowering, Laying and Jointing H. D. P. E./M. D. P. E. pipes in proper position including all specials by compression fitting/electrofusion and butt fusion jointing procedure as per relevent IS Code complete with all materials for jointing procedure like Electrofusion machine, Electric heater/butt fusion welding machine with hydraulic jack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part II A.) PE-100 a) 6 Kg/Sq. cm : 110mm dia

20

-

121.8

... More
Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete.

12.55

-

88.2

... More
Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmentalstore, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. Dia 150 mm without bypass

2

-

10251

... More
Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc.complete. (Rate for all class of valves.) Dia 150 mm without bypass

2

-

3748.5

... More
Sub Work No.2:-Switch House Providing and laying cast in situ/Ready Mix Cement Concrete of M2O grade RCC Double rim bored pile of 300 mm dia. each of load capacity as per design and of specified diameter of pile and bulb as directed, sunk to the required depth through all strata except rock, excluding provision of reinforcement including placing with fully automatic microprocessor based PLC with SCADA enabled reversible DrumType mixe /concrete Batch mix plant (Panmixer) etc. complete .With fine aggregate (Crushed sand VSI Grade) by tremie arrangement compaction of concrete including chipping anddressing etc. complete. (Excluding steel reinforcement) Chipping and dressing of the R.C.C. piles upto 0.60 meter including cleaning reinforcement and removal of dismantled materials upto a distance of 50 meter beyond the building area etc. for providing pile caps.Spec :(As directed by Engineer in Charge

20

-

1313.55

... More
Providing and laying in situ CementConcrete M-15 of trap/ granite / quartzite /gneiss metal for foundation and beddingincluding bailing out water, form work,compaction, curing, etc. complete.(Cement 5.90 bags / cum) Under pile caps Under beams

0.51

-

6514.2

... More
Providing and laying Cast in situ /Ready Mix cement concrete M-20 of trap metal for R.C.C. pile caps as per detailed designs and drawings, including bailing out water manually, centering, formwork, laying/pumping, compacting, finishing and curingetc. with fully automatic microprocessor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete.with Crushed sand VSI Grade/V.S.I. quality Artificial Sand, complete. (Excluding steel reinforcement

0.97

-

7910.7

... More
Providing and casting in situ C.C. of trap / granite/ quartzite / gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S.or Tor reinforcement) 1) Column M200

2.68

-

9255.75

... More
2) Beam & Lintels M200

2.1

-

9107.7

... More
3) Slab M200

2.81

-

9778.65

... More
4) Chajja M200

0.16

-

9736.65

... More
Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete (including cost of binding wire). (Bd-F- 17/306)

1.16

-

102066.3

... More
Providing second class Burnt Brick masonry with conventional/I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering andscaffolding etc. Complete.

5.87

-

7948.5

... More
Providing and fixing in position. (as per I.S.1868/1982) Aluminium sliding window of two tracks with rectangular pipe having over all dimension 63.50x38.10x1.02 mm at weight 0.547 Kilogram/Running metre. and window frame bottom track section 61.85x31.75x1.20 mm at weight 0.695Kilogram/Running metre.

2.4

-

5886.3

... More
Providing and fixing steel frame door of angle 50 x 50 x 6 mm with mild steel bars 16 mm dia. horizontally at 10mm c/c for ventilator portion including iron hold fast boxes for fixing shutters including welding, finishing,painting etc. complete.

1.68

-

1959.3

... More
Providing and fixing M.S. door 24 Kilogram/Square Metre of various size as per detailed drawingswithout hot dip coating, iron fixtures and fastenings and 3 coats of oil painting etc

1.68

-

3184.65

... More
Providing internal cement plaster 12 mm thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc.complete.

31.75

-

269.85

... More
Providing neeru finish to plastered surfaces in all positions including scaffolding and curing etc. complete.

31.75

-

64.05

... More
Providing internal cement plaster 20mm. thick in Single coats in cement mortar 1:3 withoutneeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc.complete.

29.52

-

394.8

... More
Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surfaces including leaning, preparing the plaster surface, applying primercoat, scaffolding if necessary, and watering the surface for two days etc complete.

29.52

-

249.9

... More
Providing and applying plastic emulsion paint of approved quality, colour and shade to new surface in three coats including scaffolding, preparing the surface. (excluding primer coat) etc. complete.

31.75

-

105

... More
Providing and laying matt finish ceramic tiles of having size 30 cm x 30 cm confirming to I.S.15622/2006 (groupDII-A) and 7 to 8 mm thick for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with white/colour cement slurry cleaning curing etc. complete.

6.25

-

1214.85

... More
Providing and fixing in position M.S. ladder 0.50 M wide consisting of 75 x 10 mm M.S. flats as stringers and 16 mm dia M.S. bars in double rows as steps placed at 25 cm c/c including cost of material and labour involved, welding, anchoring and applying 3 coats of anticorrosive paint, etc. complete as directed by Engineer-in-charge.

5

-

1567.65

... More
Sub Work No.3:- Pure Water Pumping Machinery Providing, erecting and giving test of submersible pump set 150 mm conforming to IS 8034 and motor conforming to IS 9283, with water proof winding. Pump shall be suitable fopr various delivery head and discharge with stainless steel shaft. Motor suitable for working on 415 V+/- 10%, Ph, 50 Hz A.C. Supply, with cable guard, thrust carbon/fiber bearing to withstand entire hydraullc thrust. The pump set shall be suitable for direct coupling, with suitable suction strainer. Pump should have suitable discharge out let as per manufacturer'sdesign. Antithrust stream lined non return valve shall be provided with the pump 3 m. Submersible copper conductor cable, in single/double run and 2 pair of erection clamp 65 mm width 10 mm thick shall be provided with each pump. 100 mm Pump duties 10 H P

2

-

47026

... More
Providing ISI mark G.I. pipe of following class and dia. excluding GST levied by GOI & GOM in all respect, inspection charges, transportation to stores, etc. complete as per IS-1239/2004. Note : One coupler shall be provided with each full length of pipe cost of which is included in rates below. 150 mm dia

40

-

914

... More
Providing and supplying ISI standard MS specials of required thickness with 3 coats of approved make epoxy paint (Shalimar, Ciba or Mahindra & Mahindra make) from inside and outside excluding all statutory duties & taxes such as GST levied by GOI & GOM in all respect, inspection charges, transportation to stores / site, and stacking, etc. complete.

20

-

141

... More
Providing & fixing 100 mm G I Bend

6

-

714

... More
Providing & fixing 100mm G I Nipple

4

-

466

... More
Providing & fixing 150 mm Sluice vlave PN 1 without bypass SS Spindal CIDF IS 780

2

-

9107

... More
Providing & fixing 150 mm reflex valve PN 1 without bypass IS 5312

2

-

7985

... More
Providing, erecting Pressure gauge of required range complete with syphon tube,isolating cock suitable for 12 mm dia G.I.Pipe. Pressure gauge shall be installed asdirected, with tapping on rising main.Pressure gauge (100 mm dia)

2

-

757

... More
Supply & erection of capacitor APP 2 KVAR .

5

-

343

... More
Supplying and erecting Fully AutomaticStar Delta starter to operate squirrel cageinduction motor working on 380- 440 Volt,3 phase, 50 Hz with no volt coil, over load element, and ON - OFF push buttons, withnecessary material and connected tosupply, etc complete. Starter with originalsheet steel encloser.LG 3-1 7.5 HP & Up to 12.5 HP Each 6043 180 6223

2

-

7150

... More
Internal Wiring panel of 7.50 Hp. Dual

1

-

1792

... More
Structure & Lifting equipment Providing structural steel work in rolledstanchions fixed with connecting platesor angle cleats as in main and crossbeams, hip and jack rafters, purlinsconnecting to truss members and like asper detailed designs and drawings or asdirected by Engineer-in-charge includingcutting,fabricating, hoisting, erecting,fixing in position, making riveted / bolted /welded connections and one coat ofanticorrosive paint and over it two coats ofoil painting, etc. complete. (Bd-C-3/275)

0.6

-

71286

... More
Providing, erecting triple spur gear type Chain Pulley Block suitable for capacity 1 ton with 6 m lift complete with load chainand hand chain suitable for above lift,tested to 50% over load as per IS 3832carrying ISI markLF 1-1 1 Tonne Capacity

1

-

11830

... More
Travelling TrolleyProviding, erecting Travelling Trolley of 1 ton capacity as below with 6 m lift, tested to50% over loadL

1

-

9287

... More
Panel Board Providing , installing & commissioning main control pannel board including V.meter & A. meter of suitable range single phase prevention 8 Nos. of phase indicater lamps with colour glass of 230 V rotary switch over load capacitor suitable for 7.50HP and 12.50BHP pump etc.complete.

1

-

50430.25

... More
MSECo material for Electric supply Supplying and erecting static energy meter 440 V 50 Hz. 100AISI mark meter AC 3 phase 4 wires LCD/LED display complete erected on polished teak wood board duly wired withrequired size of weather proof PVC wires duly tested for class IIaccuracy by electric supply company.Each 5401 237 5638

1

-

5919.9

... More
Supplying and erecting ISI mark GI pipe 25 mm. dia. ‘B’ class atposition with accessories complete. Specification no. CW-PLB/GP.m 286 50 336

3

-

352.8

... More
Supplying, erecting & terminating XLPE armoured cable 2 core 6 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12SWG) G.I. earth wire complete erected with glands & lugs, on wall/trusses/pole or laid in provided trench/ pipe as per specification no.CB-LT/ALm 78 17 95

50

-

112.35

... More
Sub Work No.4 :- Raw Water Rising Main From Injection Well to WTP Providing and supplying in standard lengths Polyethelene Pipes, confirming 140 mm dia. 6 kg/sq.cm

3000

-

610

... More
Proividing and supplying HDPE specials. considered for cost ofspecials (for estimate purpose only) Couplers 140

3

-

1257

... More
Equal Tee 110

6

-

1957

... More
Reducer 110x90

6

-

642

... More
Reducer 90 x 63

6

-

495

... More
LNPE 140

12

-

1445

... More
Providing and supplying ISI mark CI D/F reflux valves (non-return valves) of following dia including all taxes (Central and local), railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental stores / site, unloading, stacking, etc. complete. 100 mm dia.

3

-

5713

... More
Providing and supplying Air Valves as per IS- 14845-2000 and MJP’s standard specifications of approved make and quality of following diameters including railway freight, inspection charges, unloading from railway wagons, loading into truck, transportation upto departmental stores, unloding and stacking excluding GST levied by GOI & GOM in all respect etc. complete 25 mm

6

-

1054

... More
Providing and fixing in position air valve shaft including providing and fixing GI Medium Class or 6 mm thick M.S. pipe shaft 2.70 M long over branch flange of air valve tee, providing PCC block of M-150 concrete,150 mm thick around the air valve tee including encasing of vertical shaft in PCC M 150 as shown in type design together with providing and making flanged joints wherever required and fixing of air valve tee, etc. complete as per type design and as directed by Engineer -in- charge for following diameter of pipe line (type design attached.) Foundation in B. C. Soil or Any Other Soil.

6

-

7972

... More
Providing double flange sluice valve (scour valve) confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking etc. complete Sluice valves - PN -1.0 (With by pass arrangement)100 mm

3

-

6835

... More
Providing ISI standard R.C.C. pipes in standard lengths of following class and diameter suitable for either collar joints or rubber ring joints, excluding GST lev-ied by GOI & GOM in all respect including inspection charges, transport to departmental stores, unloading and stacking etc. complete as per IS-458/1988. Class NP-II - 200mm dia

10

-

327

... More
Excavation for foundation / pipe trenches in earth, soils of all types, sand gravel and soft murum including removing the excavated material upto a distance of 50 m, stacking and spreading as directed, dewatering, shoring and strutting, preparing the bed for the foundation etc. complete. Lift 0 to 1.5 M

979.8

-

157.5

... More
Excavation for foundation / pipe trenches in hard murum and boulders, W.B.M. road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. Lift 0 to 1.5 M

612.38

-

201.6

... More
Excavation for foundation / pipe trenches in hard strata, and old cement and lime masonary foundation asplalt road including removing the excavated materialupto a distance of 50 m, stacking and spreading as directed, dewatering, shoring and strutting, preparing the bed for the foundation etc. complete Lift 0 to 1.5 M

612.38

-

600.6

... More
Excavation for foundation / pipe trenches in hard rock and concrete road by chiselling, wedging, line drilling by mechanical means or by all means other than blasting including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, excluding backfilling, etc. complete by all means. Lift 0 to 1.5 M

244.95

-

1067.85

... More
Filling in plinth and floors murum bedding in trenches with approved murum from excavated materials from foundation in 15 cm to 20 cm layers including watering and compaction, etc. complete.

315

-

88.2

... More
Providing and laying in situ Cement Concrete M-15 of trap/ granite / quartzite / gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete.(Cement 5.90 bags / cum) PCC Blocks M150

2.27

-

6514.2

... More
Lowering, Laying and Jointing H. D. P. E./M. D. P. E. pipes in proper position including all specials by compression fitting/electrofusion and butt fusion jointing procedure as per relevent IS Code complete with all materials for jointing procedure like Electrofusion machine, Electric heater/butt fusion welding machine with hydraulic jack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part II 140 mm dia. 6 kg/sq.cm

3000

-

112.35

... More
Hydraulic testing of H. D. P. E./ M. D. P. E.pipe line to specified pressure including cost of all materials and labour and water for testing for specified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour,operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position.. 140 mm dia. 6 kg/sq.cm

3

-

13023.15

... More
Lowering, laying and jointing in position following C.I. D/F Reflux valves, Butterfly valves and Sluice valves including cost of all labour, jointing material, including nut bolts and giving satisfactory hydraulic testing, etc. complete. 100 mm dia.

3

-

2385.6

... More
Lowering, laying and fixing in proper alignment and position all types of C.I. air valves as directed by Engineer-in-charge including cost of conveyance from stores to site of work, cost of all material and giving satisfactory hydraulic testing, etc. complete.(for all class of valves). 25 mm

6

-

228.9

... More
Lowering, laying and jointing in position C.I. D/F Sluice valves (Scour valve) including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. (Rate for all class of valves.) Sluice valves - PN -1.0 (With by pass arrangement)100 mm

3

-

2385.6

... More
Lowering, laying and jointing in proper grade and alignment R.C.C. pipes with collar joints in C.M.1:1 proportion or socketed R.C.C. pipes with rubber joints (excluding cost of rubber ring or R.C.C. collar,) including cost of conveyance from stores to site of work, cost of jointing material, labour, etc. complete as directed by Engineerin- charge (For all class of pipes.) as per IS- 783-1985. Class NP-II - 200mm dia

20

-

135.45

... More
Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete.

2088.32

-

88.2

... More
Sub work No. 5 :- Pressure Filter Room Excavation for foundation/ pipe trenches in earth,soils of all types,sand,gravel and soft murum, including removing the excavated material upto a distance of 50metres and lifts as below,stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete

2.98

-

157.5

... More
Excavation for foundation/ pipe trenches in hard murum including removing the excavated material upto a distance of 50M and lifts as below,stacking and spreading as directed by Engineer-in-charge,normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete

4.26

-

178.5

... More
Excavation for foundation/ pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50M beyond the area and lifts as below,stacking as directed by Engineer-in-charge,normal dewatering, preparing the bed for foundation and excluding backfilling,etc.complete.

1.28

-

600.6

... More
Providing and Laying in situ Cement concreteM - 150 of trap / granite / quartzite / gneiss metal for foundation and bedding including bailing out water form work, compaction curing etc. complete.

5.43

-

6514.2

... More
Providing and casting in situ Cement Concrete of trap/ granite/ quartzite/gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer in-charge including normal dewatering, centering, formwork, compaction, finishing the formed surfaces with CM 1:3 of sufficient minimum thickness if special finish is to be provided and curing, etc. complete. (Excluding M.S.or Tor reinforcement) RCCM-200 for all types of columns.

1.5

-

9255.75

... More
Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings,fins,arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars,binding with wires or tack welding and supporting as required,etc. complete(including cost of binding wire) TOR Steel

0.15

-

102066.3

... More
Providing structural steel work in rolled sections like joists, channels, angles, tees, etc. as per detailed designs and drawings including fixing in position without connecting plates, braces,etc.and one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade, etc. complete. (Bd-C-2/275

1.4

-

102066.3

... More
Filling in plinth and floors murum bedding in trenches with approved murum from excavated materials from foundation in 15cm to 20 cm layers including watering and compaction, etc. complete. (Bd-A-10/263)

12

-

88.2

... More
Providing and fixing colour coated Zincalume(R)AZ150 (min150gms/sq.mt.total on each side) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45mm BaseMetal Thickness (BMT) (0.5mmTCT), Hi-strength steel with min.550MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy(55%aluminium 43.4%zinc 1.6%silicon) with COLORBOND(R) steel quality super durable polyester paint coat (within organic pigment). The paint shall have a total coating thickness of nominal 35um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom.950-1050mm effective cover width and nominal 25-30mm deep ribs with subtle square fluting in the five panatnominal180-250mm center-to-center.The end rib shall be designed for anti-capillary groove.andreturn leg.The feed material should have coil manufacturers product details marked aregularinterval. Including fasteners with min.fastened withmin. 25umZinc-Tinalloycoated, Hexhead, self-drilling screw etc. complete. (weight of profile 4.52 Kilogram/SquareMetre)

66.13

-

1149.75

... More
Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9mm with lock plate of3.15mm thickness reinforced with 35x35x5mm angle section fitted with sliding bolts and handles for both sides, deepM.S.channel section of depth and thickness not less than 65mm and 3.15mm respectively with hold fast arrangements,M.S. Bracket plate300x300x3.15mm minimum size and shape with square bar, suspension shaft of minimum 32mm diameter,hood cover ofM.S.sheet not less than 0.9mm thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worm sofhigh grade cast iron or mild steel and one coat of red lead primer etc. omplete. I.S. 62481979) (With mechanical gear)

3.15

-

4966.5

... More
Providing and fixing steel window of various size as per detailed drawing without hot dip zinc coating,without ventilators, including fabricating/ glazing with plain/ obscured glass panels of approved type and quality, iron oxidised fixtures and fastenings, finishing with oil painting two coats complete (with guard bars 12 mm square at 10 cm c/c.)

2.4

-

4709.25

... More
Providing and applying two coats of lead/zinc base oil paint/bituminious paint of approved colour to new structural steel work and iron work in buildings including scaffolding if necessary, cleaning and preparing the surface etc. complete. (excluding primer coat)

11.1

-

89.25

... More
Providing and applying two coats of waterproof cement paint of approved manufacture and of approved colour to the plastered surfaces including scaffolding if necessary,cleaning and preparing the surface, watering for two days etc.Complete

14.04

-

77.7

... More
Light Fitting

4

-

450

... More
Sub work No. 6- Pressure Filter Providing, supplying, installing & testing of Aqua Catalytic Oxidation filteration collaboration with WMC & Watch water Treatment systems, Germany, new innovative catalytic oxidation filteration media technology ZEOSORB media filteration of suspended solids upto less 3 microns Pressure filter 20 Cum/Hr.

1

-

1294642.86

... More
Sub Work No. 7:-Pure Water Rising main Providing and supplying in standard lengths Polyethelene Pipes, confirming to IS 4984/ 14151 12786 / 13488 with nesessary jointing material like mechanical connector i. e. thread / insert joint / quick release coupler joint / compression fitting joint or flanged joint excluding coupler/specials, including transportation and freight charges, inspection charges, loading / unloading charges, conveyance to the departmental stores & stacking the same in closed shade duly protecting from sunrays & rains, excluding GST levied by GI & GOM in all respect etc. complete. 140 mm dia. 6 kg/sq.cm

100

-

610

... More
Proividing and supplying HDPE specials. considered for cost ofspecials (for estimate purpose only) Couplers 140

1

-

1257

... More
Equal Tee 125

1

-

2700

... More
Reducer 125x90

1

-

713

... More
Providing and supplying ISI mark CI D/F reflux valves (non-return valves) of following dia including all taxes (Central and local), railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental stores / site, unloading, stacking, etc. complete. 100 mm dia.

1

-

5713

... More
Providing and supplying Air Valves as per IS- 14845-2000 and MJP’s standard specifications of approved make and quality of following diameters including railway freight, inspection charges, unloading from railway wagons, loading into truck, transportation upto departmental stores, unloding and stacking excluding GST levied by GOI & GOM in all respect etc. complete 25 mm

1

-

1054

... More
Providing and fixing in position air valve shaft including providing and fixing GI Medium Class or 6 mm thick M.S. pipe shaft 2.70 M long over branch flange of air valve tee, providing PCC block of M-150 concrete,150 mm thick around the air valve tee including encasing of vertical shaft in PCC M 150 as shown in type design together with providing and making flanged joints wherever required and fixing of air valve tee, etc. complete as per type design and as directed by Engineer -in- charge for following diameter of pipe line (type design attached.) Foundation in B. C. Soil or Any Other Soil.

1

-

7972

... More
Providing double flange sluice valve (scour valve) confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking etc. complete Sluice valves - PN -1.0 (With by pass arrangement)100 mm

2

-

6835

... More
Excavation for foundation / pipe trenches in earth, soils of all types, sand gravel and soft murum including removing the excavated material upto a distance of 50 m, stacking and spreading as directed, dewatering, shoring and strutting, preparing the bed for the foundation etc. complete. Lift 0 to 1.5 M

40.25

-

157.5

... More
Excavation for foundation / pipe trenches in hard murum and boulders, W.B.M. road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. Lift 0 to 1.5 M

20.13

-

201.6

... More
Excavation for foundation / pipe trenches in hard strata, and old cement and lime masonary foundation asplalt road including removing the excavated materialupto a distance of 50 m, stacking and spreading as directed, dewatering, shoring and strutting, preparing the bed for the foundation etc. complete Lift 0 to 1.5 M

20.13

-

600.6

... More
Filling in plinth and floors murum bedding in trenches with approved murum from excavated materials from foundation in 15 cm to 20 cm layers including watering and compaction, etc. complete.

10.5

-

88.2

... More
Providing and laying in situ Cement Concrete M-15 of trap/ granite / quartzite / gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete.(Cement 5.90 bags / cum) PCC Blocks M150

2.27

-

6514.2

... More
Lowering, Laying and Jointing H. D. P. E./M. D. P. E. pipes in proper position including all specials by compression fitting/electrofusion and butt fusion jointing procedure as per relevent IS Code complete with all materials for jointing procedure like Electrofusion machine, Electric heater/butt fusion welding machine with hydraulic jack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part II 140 mm dia. 6 kg/sq.cm

100

-

112.35

... More
Hydraulic testing of H. D. P. E./ M. D. P. E.pipe line to specified pressure including cost of all materials and labour and water for testing for specified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour,operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position.. 140 mm dia. 6 kg/sq.cm

0.1

-

13023.15

... More
Lowering, laying and jointing in position following C.I. D/F Reflux valves, Butterfly valves and Sluice valves including cost of all labour, jointing material, including nut bolts and giving satisfactory hydraulic testing, etc. complete. 100 mm dia.

1

-

2385.6

... More
Lowering, laying and fixing in proper alignment and position all types of C.I. air valves as directed by Engineer-in-charge including cost of conveyance from stores to site of work, cost of all material and giving satisfactory hydraulic testing, etc. complete.(for all class of valves). 25 mm

1

-

228.9

... More
Lowering, laying and jointing in position C.I. D/F Sluice valves (Scour valve) including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. (Rate for all class of valves.) Sluice valves - PN -1.0 (With by pass arrangement)100 mm

2

-

2385.6

... More
Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete.

68.46

-

88.2

... More
Sub Work No.8:-RCC ESR Capacity 121000 Litres, Designing (aesthetically), and constructing RCC elevated service reservoirs of following capacity with RCC staging consisting of columns, internal and external bracings spaced vertically not more than 4.5 meters centre to centre for E.S.R. having capacity 500 m3 & not more than 6 m c/c for E.S.R.having capacity above 500 m3 including excavation in all types of strata, foundation concret, cement plaster with water proofing compound to the inside face of the container including refilling disposing of the surplus stuff within a lead of 50 meters, all labour and material charges including lowering, laying, erecting, hoisting and jointing of pipe assembly of inlet, outlet, washout, overflow and bypass arrangements as per departmental design. providing and fixing accessories such as Stainless steel ladder inside and M.S. ladder with G.I. railing outside, C. I. manhole frame and covers water level indicatiors, lightening conductor, G. I. pipe railing around walk way and top slab, providing spiral staire case from ground level to roof level, M.S.Grill gate of 2 Mtrs height with locking arrangement, B.B. masonry chambers for all valves, ventilating shafts, providing and applying three coats of acrylic emulsion with silicon additives paint to the structure including roof slab and epoxy paint to internal surface & anti-termite treatment for underground parts of the structures and giving satisfactory water tightness test as per I.S. code, The job to include painting the name of the scheme and other details on the reservoir as per the directions of Engineer-in-charge. Cost of 121,000 litres capacity, 12 m staging height Notes :- 1) The design of the srtucture be in accoradance with relevant I S specification ( I S 3370 - 1965 or revised ) 2) The design shall satisfy the stipulations as per I S 1893 - 1984 and I S 13920 / 1993 for seismic force and I S -11682 / 1985 for RCC staging of overhead tanks. 3) For design having more than 6 columne,provision of internal bracing is obligatory.External bracings is also obligatory. 4) The entire structure shall be in M - 300 mix only. 5) Plain round mild steel bars grade-I confirming to I S 432 part-I or high yield strength deformed bars confirming to I S 1786 or I S 1139 shall be used,grade- II mild steel bars will not be allowed. 6) Irrespective of the type of foundation proposed in the design,one set of bracing be provided at the ground level. 7) These rates include providing M S ladder for E S R s upto 2 lakh litres capacity and providing spiral staircase for E S R above 2 lakh litres capacity. 8) Staging shall have to be designed with stresses of M- 200 concrete for ESR. However all RCC construction should be done in M-300. 9) These rates are including the cost of uplift pressure if any and entire dewatering during execution. In case of water logging area where water is stretch at shallow depth,extra provision of dewatering shall be made as per site condition. 10) All conditions given in the Member Secretary's Circular No. MJP/ TS-I/350/1668 dt.2-8-97 and MJP / S-I/350/2127 dt. 13-7-99 shall be strictly followed and additional cost,if any,due to these conditions is included in the rates mentioned below. 11) 75% part rate shall be payable for reinforcement concrete and plastering items of containers of ESR till satisfactory hydraulic testing for water tightness is given; and till that work shall be treated as incomplete.

1

-

2522071.65

... More
Providing and supplying ISI standard welded DI double flanged pipe excluding GST levied by GOI & GOM in all respect but including railway freight, insurance, unloading from railway wagon, loading into truck transport to store, unloading, stacking etc. complete as directed by Engineer -in- charge. (for 2.75 m bare pipe) 150 mm dia. DI D/F pipe

65

-

2694

... More
Providing and supplying double flange sluice valves confirming for IS 2906/14846 including warn gear arrangement as per test pressure stainless steel spindle caps including all taxes transportation etc complete. 150 mm dia D/F SI.Valve PN 1.0

3

-

10251

... More
Providing and supplying ISI standard D. I. specials & fitting with sealing rubber gasket of S.B.R,complete with cast iron follower gland and M. S. nut bolts coated or otherwise protected from rusting and suitable for D.I.pipes including cost of labour, materials, and transportation to stores, loading and unloading excluding GST levied by GOI & GOM in all respect etc. complete as per IS-9523.

300

-

111

... More
Sub WOrk No.9:- Distribution System Providing and supplying in standard lengths Polyethelene Pipes, confirming to IS 4984/ 14151 12786 / 13488 with nesessary jointing material like mechanical connector i. e. thread / insert joint / quick release coupler joint / compression fitting joint or flanged joint excluding coupler/specials, including transportation and freight charges, inspection charges, loading / unloading charges, conveyance to the departmental stores & stacking the same in closed shade duly protecting from sunrays & rains, excluding GST levied by GI & GOM in all respect etc. complete. 90 mm dia 6 kg/cm2

5000

-

244

... More
110 mm dia 6 kg/cm2

1223

-

354

... More
140 mm dia 6 kg/cm2

439

-

610

... More
Proividing and supplying HDPE specials. considered for cost ofspecials (As Per Actual used same shall be paid at rate SSR 2021-22)

1

-

171585.6

... More
Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. 80mm mm dia PN 1.

6

-

5132

... More
100 mm dia PN 1.

2

-

6835

... More
125 mm dia PN 1.

1

-

8548

... More
Excavation for foundation / pipe trenches in earth, soils of all types, sand gravel and soft murum, Hard Murum including removing the excavated materialupto a distance of 50 m, stacking and spreading as directed, dewatering, shoring and strutting, preparing the bed for the foundation etc. complete

2763.33

-

157.5

... More
Excavation for foundation / pipe trenches in hard murum, and boulders, WBM road including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding backfilling, etc complete.

1151.39

-

201.6

... More
Excavation for foundation / pipe trenches in hard strata, and old cement and lime masonary foundation asplalt road including removing the excavated materialupto a distance of 50 m, stacking and spreading as directed, dewatering, shoring and strutting, preparing the bed for the foundation etc. complete

460.56

-

600.6

... More
Excavation for foundation / pipe trenches in hard rock and concrete road by chiselling, wedging, line drilling by mechanical means or by all means other than blasting including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, excluding backfilling, etc. complete by all means. Lift 0 to 1.5 M

230.28

-

1067.85

... More
Filling in plinth and floors / excavated trenches with approved excavated materials from foundation in 15 to 20 cm. Layers, including waering compaction, etc. complete

599.58

-

88.2

... More
Lowering, laying and jointing with HDPE pipes and specials of following class and diameter including cost of conveyance from stores to site of works includingcost of all labour, material, except cement solvent, rubberring, giving satisfactory hydraulic testing as per IS code,etc. complete (with cement solvent joint/ring fit joint) 90 mm dia 6 kg/cm2

5000

-

70.35

... More
110 mm dia 6 kg/cm2

1223

-

73.5

... More
140 mm dia 6 kg/cm2

439

-

112.35

... More
Hydraulic testing of HDPE pipe line to specified pressure including cost of all materials and labour and water for testing for specified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position. 90 mm dia 6 kg/cm2

5

-

7814.1

... More
110 mm dia 6 kg/cm2

1.22

-

7814.1

... More
140 mm dia 6 kg/cm2

0.44

-

13023.15

... More
Lowering, laying and jointing in proper grade and alignment R.C.C. pipes with collar joints in CM 1:1 proportion or socketed R.C.C. pipes with rubber joints (excluding cost of rubber ring or R.C.C. collar), including cost of conveyance from stores to site of works, cost of jointing material, labour, giving hydraulic testing, etc. complete as directed by Engineer-in-charge. (IS-783/1985) 200 MM Dia NP II Class

50

-

135.45

... More
Labour charges for fixing of various valves of following nominal dia. Including cost of conveyance from stores to site of work, labour, jointing materials, giving satisfactory hydraulic test etc. complete 80mm mm dia PN 1.

6

-

1824.9

... More
100 mm dia PN 1.

2

-

2385.6

... More
125 mm dia PN 1.

1

-

2969.4

... More
Providing and fixing C.I. road box including loading, unloading and carting to site of work including all necessary excavation in all types of strata and fixing in murum packing, etc. complete. 100 mm x 225 mm (20 kg)

9

-

1621.2

... More
Refilling the trenches with available exvavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete

3659.56

-

88.2

... More
Providing and fixing road junction/ information sign boards of size 1.80 x 1.20 Meter Prepared 16 guage M.S.sheet on frame of size 40x40x5 mm with cross bracing of size 35x35 x 5 mm including painting with one coat of zinc cromate stoving primer and two coats each of green/white back ground and back side gray stove enamelled, bonded with red retro reflective sheet Engineering grade, border / letters / numeral /arrows, coated with non pealable crystal clear protective transperent coat retaining 100% reflection includingtwo angle iron post of size 65 x 65 x 6 mm of 3.65 m. long inflated at bottom drilled on top and painted in whiteand black bands of 30 cm. with 4 Nos. high strength G.I. bolts and nuts of size 10 mm dia. and 20 mm long sheet and angle iron post in one piece without joints including all taxes, conveying, fixing in ground with cement concrete 1:4:8 block of 60 cm x 60 cm x 75 cm size as directed by Engineer-in- charge etc. complete. Mild Steel Board with Engineering Grade.

1

-

20487.6

... More
Subwork No 10 :- RUNNING THE SCHEME (FOR ONE MONTH) Commissioning, running and maintaining the scheme to quantities, rated capacity, including manning necessary personnel such as operator, valveman, etc. as per requirements of the scheme and who should also administer chemical dose for a period of 1 month for individual scheme and 3 months for regional scheme, together with training of personnel spared by MJP / Local Body and handing over the scheme to Local Body after completion of the above period as directed by Engineer-in-charge. Note : Required chemicals to be supplied by Department free of cost and electricity bill will also be paid by the Department. a) For single village ( One Month ).

1

-

32103



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.