Rashtriya Chemicals And Fertilizers Limited Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Rashtriya Chemicals And Fertilizers Limited - RCFL Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date1 Aug 2024
Closing Date23 Aug 2024
Tender Amount₹ 1,73,95,163 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Get the Best Price For TMT
Starting from
₹41,100/MT*
Maharashtra

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
PROVIDING SECOND CLASS BURNT BRICK MASONRY WITH CONVENTIONAL/ I.S. TYPE BRICKS IN CEMENT MORTAR 1:6 IN FOUNDATIONS AND PLINTH OF INNER WALLS/ IN PLINTH EXTERNAL WALLS INCLUDING BAILING OUT WATER MANUALLY , STRIKING JOINTS ON UNEXPOSED FACES, RAKING OUT JOINTS ON EXPOSED FACES AND WATERING ETC. COMPLETE.

10

-

7755

... More
PROVIDING SECOND CLASS BURNT BRICK MASONRY WITH CONVENTIONAL/ I.S. TYPE BRICKS IN CEMENT MORTAR 1:6 IN SUPERSTRUCTURE INCLUDING STRIKING JOINTS, RAKING OUT JOINTS, WATERING AND SCAFFOLDING ETC. COMPLETE

55

-

7994

... More
PROVIDING UNCOURSED RUBBLE MASONRY OF TRAP / GRANITE / QUARTZITE / GNEISS STONES IN CEMENT MORTAR 1:6 IN FOUNDATION AND PLINTH OF INNER WALLS / IN PLINTH OF EXTERNAL WALLS INCLUDING BAILING OUT WATER MANUALLY , STRIKING JOINTS ON UN EXPOSED FACES AND WATERING ETC.COMPLETE.

30

-

5025

... More
PROVIDING UNCOURSED RUBBLE MASONRY OF TRAP / GRANITE / QUARTZITE / GNEISS STONES IN CEMENT MORTAR 1:6 IN SUPERSTRUCTURE INCLUDING RACKING OUT JOINTS WHEN PLASTERING IS TO BE DONE / STRIKING JOINTS WHEN NO PLASTERING IS TO BE DONE ON INSIDE WATERING AND SCAFFOLDING ETC.COMPLETE.

20

-

5534

... More
PROVIDING AND LAYING DAMP PROOF COURSE 50 MM THICK IN M20 CEMENT CONCRETE LAYER AND BITUMEN / USING CEMENT WITH WATERPROOFING COMPOUND CURING, FORMWORK ETC. COMPLETE.

3000

-

432

... More
PROVIDING AND FIXING CHICKEN MESH OF 22 GAUGE, WITH ABOUT 30 CM. WIDTH AT THE JUNCTION OF R.C.C MEMBERS AND BRICK WORK, OF APPROVED QUALITY INCLUDING FIXING MESH IN POSITION BY NECESSARY DRILLING IN CONCRETE /B.B.MASONRY AND OR TYING BY BINDING WIRE ETC. COMPLETE.

25

-

57

... More
PROVIDING AND APPLYING TWO COATS OF WALL CARE PUTTY ON PLASTERED SURFACE AND CEILING AND WALLS TO PREPARE SURFACE EVEN AND SMOOTH OF APPROVED MAKE, ETC COMPLETE.

3250

-

90

... More
PROVIDING AND LAYING CEMENT CONCRETE PIPE OF IS 458:2003 NP-2 CLASS OF 450MM DIAMETER IN PROPER LINE, LEVEL AND SLOPE INCLUDING PROVIDING AND FIXING COLLARS IN CEMENT MORTAR 1:2 AND CURING ETC. COMPLETE.

5

-

1949

... More
PROVIDING AND LAYING CEMENT CONCRETE PIPE OF IS 458:2003 NP-2 CLASS OF 600MM DIAMETER IN PROPER LINE, LEVEL AND SLOPE INCLUDING PROVIDING AND FIXING COLLARS IN CEMENT MORTAR 1:2 AND CURING ETC. COMPLETE.

2.5

-

2733

... More
PROVIDING AND FABRICATING STRUCTURAL STEEL WORK IN ROLLED SECTIONS/HOLLOW PIPE SECTIONS LIKE JOISTS, CHANNELS, ANGLES, TEES ETC. AS PER DETAILED DESIGN AND DRAWINGS OR AS DIRECTED INCLUDING CUTTING, FABRICATING, HOISTING, ERECTING, FIXING IN POSITION MAKING RIVETED / BOLTED /WELDED CONNECTIONS WITHOUT CONNECTING PLATES, BRACES ETC. AND INCLUDING ONE COAT OF ANTICORROSIVE PAINT AND OVER IT TWO COATS OF OIL PAINTING OF APPROVED QUALITY AND SHADE ETC. COMPLETE.

1.5

-

101844

... More
PROVIDING AND LAYING PLAIN CEMENT CONCRETE (1 CEMENT: 3 FINE AGGREGATE :6 GRADED STONE AGGREGATE 20 MM NOMINAL SIZE), MANUAL / MACHINE MIXED IN FOUNDATIONS, PLINTH, UNDER FLOORS AS PER EIC ETC., INCLUDING ALL NECESSARY COST OF CENTERING AND SHUTTERING, ROUGHENEING / FINISHING AS REQUIRED, FINISHING UNEBEN AND HONEYCOMBED SURFACES WITH CEMENT MORTAR 1:3 PLASTER & CURING ETC. COMPLETE. (MINIMUM CEMENT CONTENT SHALL NOT BE LESS THAN 320 KG/CUM.)

15

-

5830

... More
PROVIDING AT ALL HEIGHTS 12 MM THICK CEMENT PLASTER ON BRICK WORK, EXPOSED SURFACES OF RCC LINTELS, BEAMS, ETC., COMPLETE IN ALL RESPECTS AND AS DIRECTED WITH CEMENT PLASTER MIX : 1:4(1 CEMENT : 4 PACKED BAG SAND), INCLUDING NECESSARY SCAFFOLDING, CURING ETC. COMPLETE.

250

-

278

... More
PROVIDING NEERU FINISH TO PLASTERED SURFACES IN ALL POSITIONS INCLUDING SCAFFOLDING AND CURING ETC. COMPLETE.

250

-

65

... More
PROVIDING EXTERNAL SAND FACED CEMENT PLASTER IN CEMENT SAND MORTAR 1:4 (1CEMENT:4 PACKED BAG SAND) USING PACKED BAG SAND IN TWO LAYERS INCLUDING PROVIDING BASE COAT OF 12 TO 15 MM THICK MIXING APPROVED WATER PROOFING COMPOUND TO THE FIRST COAT OF PLASTER AND KEEPING BASE COAT ROUGH TO RECEIVE SAND FACED TREATMENT OF 6 TO 8 MM THICK INCLUDING SCAFFOLDING,CURING ETC. COMPLETE.

250

-

639

... More
PROVIDING AND APPLYING WASHABLE OIL-BOUND DISTEMPER OF APPROVED COLOUR AND SHADE TO OLD AND NEW SURFACES IN TWO COATS INCLUDING SCAFFOLDING, PREPARING THE SURFACES. (EXCLUDING THE PRIMER COAT.) ETC. COMPLETE.

3250

-

48

... More
PROVIDING AND APPLYING TWO COATS OF EXTERIOR ACRAYLIC EMULSION PAINT CONFIRMING TO CORRESPONDING I.S. OF APPROVED MANUFACTURE AND OF APPROVED COLOUR TO THE PLASTERED SURFACES INCLUDING CLEANING ,PREPARING THE PLASTER SURFACE, APPLYING PRIMER COAT ,SCAFFOLDING IF NECESSARY , AND WATERING THE SURFACE FOR TWO DAYS ETC COMPLETE.

1035

-

261

... More
PROVIDING AND APPLYING ONE COAT OF ALUMINIUM PAINT OF APPROVED MAKE TO NEW STRUCTURAL STEEL WORK IN BUILDING AND WORKSHOP INCLUDING SCAFFOLDING IF NECESSARY, CLEANING AND PREPARING SURFACE (EXCLUDING PRIMER COAT) ETC. COMPLETE.

25

-

86

... More
PROVIDING AND APPLYING 2 COATS OF ALUMINIUM PAINT OF APPROVED MAKE TO NEW STRUCTURAL STEEL WORK IN BUILDINGS AND WORKSHOPS INCLUDING SCAFFOLDING IF NECESSARY, CLEANING AND PREPARING THE SURFACE (EXCLUDING PRIMER COAT)ETC. COMPLETE.

25

-

128

... More
PROVIDING AND APPLYING TWO COATS OF SYNTHETIC ENAMEL PAINT OF APPROVED COLOUR TO NEW /OLD STRUCTURAL STEEL WORK AND WOOD WORK IN BUILDINGS, INCLUDING SCAFFOLDING IF NECESSARY, CLEANING AND PREPARING THE SURFACE (EXCLUDING PRIMER COAT) ETC. COMPLETE.

100

-

96

... More
PROVIDING AND APPLYING ONE COAT OF FLAT OIL PAINT OF APPROVED COLOUR TO THE OLD STRUCTURAL STEEL WORK AND IRON WORK PREVIOUSLY PAINTED IN BUILDING INCLUDING SCAFFOLDING, IF NECESSARY, CLEANING AND PREPARING SURFACE (EXCLUDING PRIMER COAT) ETC. COMPLETE.

25

-

57

... More
PROVIDING AND APPLYING TWO COATS OF FLAT OIL PAINT OF APPROVED COLOUR TO THE OLD STRUCTURAL STEEL WORK AND IRON WORK PREVIOUSLY PAINTED IN BUILDING INCLUDING SCAFFOLDING, IF NECESSARY, CLEANING AND PREPARING THE SURFACE (EXCLUDING PRIMER COAT) ETC. COMPLETE.

250

-

85

... More
PROVIDING AND APPLYING ONE COAT OF FLAT OIL PAINT OF APPROVED COLOUR AND SHADE TO INTERNAL / EXTERNAL PLASTERED SURFACES INCLUDING SCAFFOLDING IF NECESSARY, CLEANING AND PREPARING THE SURFACE (EXCLUDING PRIMER COAT) ETC. COMPLETE.

25

-

53

... More
PROVIDING AND APPLYING TWO COATS OF FLAT OIL PAINT OF APPROVED COLOUR AND SHADE TO INTERNAL / EXTERNAL PLASTERED SURFACES INCLUDING SCAFFOLDING IF NECESSARY, CLEANING AND PREPARING THE SURFACE (EXCLUDING PRIMER COAT) ETC. COMPLETE.

25

-

101

... More
PROVIDING AND APPLYING TWO COATS OF WATER PROOF CEMENT PAINT OF APPROVED MANUFACTURE AND OF APPROVED COLOUR TO THE PLASTERED SURFACES INCLUDING SCAFFOLDING IF NECESSARY, CLEANING AND PREPARING THE SURFACE, WATERING FOR TWO DAYS ETC. COMPLETE.

25

-

79

... More
PROVIDING AND APPLYING PRIMING COAT OVER NEW WOOD AND WOOD BASED SURFACES, INCLUDING PREPARING THE SURFACE BY THOROUGHLY CLEANING OIL, GREASE, DIRT AND OTHER FOREIGN MATTER, SAND PAPERING AND KNOTTING, SCAFFOLDING ETC. COMPLETE.

25

-

34

... More
PROVIDING AND APPLYING PRIMING COAT OVER NEW/OLD STEEL AND OTHER METAL SURFACES INCLUDING PREPARING THE SURFACE BY THOROUGHLY CLEANING OIL, GREASE, DIRT AND OTHER FOREIGN MATTER AND SCOURED WITH WIRE BRUSHES, FINE STEEL WOOL, SCRAPPERS AND SAND PAPER, SCAFFOLDING ETC. COMPLETE.

50

-

37

... More
PROVIDING AND APPLYING PRIMING COAT ON WOODEN/STR. STEEL SECTION//CONCRETE/ MASONARY/ ASBESTOS CEMENT PLASTERED SURFACES INCLUDING SCAFFOLDING IF NECESSARY, PREPARING THE SURFACE BY THOROUGHLY CLEANING OIL, GREASE, DIRT AND OTHER FOREIGN MATTER AS REQUIRED ETC. AS INSTRUCTED BY EIC ETC. COMPLETE.

550

-

36

... More
PROVIDING AND APPLYING WASHABLE OIL-BOUND DISTEMPER OF APPROVED COLOUR AND SHADE TO OLD AND NEW SURFACES IN ONE COAT INCLUDING SCAFFOLDING, PREPARING THE SURFACES. (EXCLUDING THE PRIMER COAT.)ETC. COMPLETE.

25

-

32

... More
PROVIDING AND APPLYING PLASTIC EMULSION PAINT OF APPROVED QUALITY, COLOUR AND SHADE TO OLD AND NEW SURFACES IN TWO COATS INCLUDING SCAFFOLDING, PREPARING THE SURFACE. (EXCLUDING THE PRIMER COAT)ETC. COMPLETE.

25

-

80

... More
PROVIDING AND APPLYING PLASTIC EMULSION PAINT OF APPROVED QUALITY, COLOUR AND SHADE TO OLD AND NEW SURFACES IN SINGLE COAT INCLUDING SCAFFOLDING, PREPARING THE SURFACE. (EXCLUDING THE PRIMER COAT)ETC. COMPLETE.

25

-

57

... More
PROVIDING AND FIXING IN POSITION (AS PER 1868 / 1982) ALUMINIUM SLIDING WINDOW OF THREE TRACKS WITH RECTANGULAR PIPE AT WEIGHT 0.637 KILOGRAM/ONE RUNNING METRE.AS PER DETAILED DRAWINGS AND AS DIRECTED BY ENGINEERINCHARGE WITH ALL NECESSARY ALUMINIUM SECTIONS FIXTURES AND FASTENINGS SUCH AS ROLLER BEARING IN NYLON CASTING AND SELF LOCKING CATCH FITTED IN VERTICAL SECTION OF SHUTTER INCLUDING 5 MM THICK PLAIN GLASS AND ALUMINIUM MOSQUITO NET SHUTTER WITH STAINLESS STEEL JALI WITH ALL REQUIRED SCREWS AND NUTS ETC, COMPLETE. WITH POWDER COATING WITH BOX

5

-

5367

... More
PROVIDING & FIXING IN POSITION ANODIZED ALUMINUM LOUVERED WINDOWS/VENTILATORS HAVING FRAME MADE OUT OF SIZE 80 X 38 MM X 1.22 MM THICKNESS BOX TYPE WITH SHEET GLASS LOUVERS 5 MM THICK AND WOODEN ENCASEMENT WHEREVER NECESSARY ETC. AS DIRECTED BY EIC.

10

-

4827

... More
PROVIDING AND FIXING MILD STEEL GRILL WORK FOR WINDOWS, VENTILATORS ETC. 20 KILOGRAM/ ONE SQUARE METRE AS PER DRAWING INCLUDING FIXTURES, NECESSARY WELDING AND PAINTING WITH ONE COATS OF ANTICORROSIVE PAINT AND TWO COATS OF OIL PAINTING COMPLETE.

200

-

2097

... More
PROVIDING & FIXING 30 MM THICK SINGLE LEAF SOLID CORE FLUSH DOOR WITH APPROVED SHADE LAMINATE (1 MM) FINISH INCLUDING NECESSARY HARDWARE, FITTINGS & FIXTURES LIKE CYLINDRICAL DOOR LOCK, CHROMIUM PLATED HANDLES ON BOTH SIDES, PVC DOOR STOPPER, BRASS MAKE ISI MARKED HYDRAULIC DOOR CLOSER, POLISH TO ALL EXPOSED SURFACES, EDGES, ETC. COMPLETE AS PER DETAIL DRAWING. IF REQUIRED, THE DOOR SHALL HAVE 2' X 3' (OR AS DIRECTED) 5 MM THK. PLAIN GLASS AT TOP FIXED WITH BEADING PATTI ALL AS SPECIFIED AND AS DIRECTED.

50

-

3784

... More
PROVIDING AND FIXING FIBER GLASS REINFORCED POLYSTER DOOR SHUTTER 35 MM THICK WITHOUT VENTILATOR INCLUDING CHROMIUM PLATED FIXTURES AND FASTENING WITH CHROMIUM PLATED HANDLES ON BOTH SIDES, ETC COMPLETE.

14.8

-

3495

... More
SUPPLYING, FITTING & FIXING IN POSITION FULLY OR PARTLY GLAZED SINGLE LEAF ANODIZED ALUMINUM DOORS OF APPROVED SHADE MADE UP FROM ALUMINIUM EXTRUDED SECTIONS GLAZED WITH 5.0 MM THICK PLAIN GLASS FIXING WITH SPECIAL GASKET, BEADING, LOCK & ALL NECESSARY FIXTURES AND FASTENINGS ETC. COMPLETE AS PER SPECIFICATIONS, DRAWINGS AND DIRECTION OF ENGINEER-IN-CHARGE. (DETAIL MATERIAL SPECIFICATION WILL BE AS FOLLOWS)I) 15 TO 16 GAUGE THICK AL SECTIONS. (DOOR BOTTOM RAIL 95X44 MM, LOCK RAIL 50X44 MM, TOP & VERICAL RAIL 47X44 MM) II) ALUMINUM ANGLE-16 GAUGE III) 6 MM THICK PLY WOODS/3.5 MM THICK HARDNER SHEET IV) 28 GAUGE ALUMINUM SHEET.

15

-

4046

... More
PROVIDING SILLS OF POLISHED KADAPPA STONE 25MM TO 30MM THICK, ON A BED OF 1:4 CEMENT MORTAR INCLUDING CEMENT FLOAT, FILLING JOINTS WITH SLURRY, CURING POLISHING AND CLEANING ETC. COMPLETE.

5

-

1084

... More
PROVIDING AND LAYING TELEPHONE BLACK / AMBA WHITE / CADBURY BROWN / RBI RED / OCEAN BROWN GRANITE STONE OF 15 TO 20 MM THICK FOR DOOR FRAME / DADO / WINDOW BOXING / PLATFORM OTTA ETC. ON C.M. 1:6 INCLUDING FILLING JOINTS WITH POLYMER BASE FILLER NOSING THE SHARP EDGES WHEREVER NECESSARY, CURING, ETC. COMPLETE..

150

-

4386

... More
PROVIDING AND FIXING GREEN MARBLE OF 18 TO 20 MM THICK FOR DOOR FRAME/ DADO/ WINDOW BOXING ETC. ON C.M. 1:6 INCLUDING FILLING JOINTS WITH POLYMER BASE FILLER NOSING / MOULDING THE SHARP EDGES WHEREVER NECESSARY, CURING, ETC. COMPLETE.

5

-

2367

... More
PROVIDING AND FIXING HEAVY DUTY INTER LOCKING CONCRETE COLOURED PAVING BLOCKS OF 80 MM THICKNESS OF HAVING A STRENGTH OF 300 KILOGRAM/SQ.CM. OF APPROVED QUALITY AND SHAPE ON A BED OF CRUSHED SAND OF 25 TO 30 MM THICK INCLUDING SKIRTING JOINTS AND CLEANING ETC. COMPLETE

10

-

1166

... More
PROVIDING AND LAYING CHEQUERED TILES OF APPROVED QUALITY OF SIZE 30 CM X 30 CM, CONFIRMING TO CORRESPONDING I.S. FOR FLOORING IN REQUIRED POSITION LAID ON A BED OF 1:4 CEMENT MORTAR INCLUDING CEMENT FLOAT, FILLING JOINT WITH CEMENT SLURRY CLEANING CURING ETC. COMPLETE.

10

-

735

... More
PROVIDING AND LAYING MIRROR / GLOSSY / MATT FINISH VITRIFIED TILES OF SOMANY / RAK / KAJARIA / NITCO / JHONSON (300 MM X 300 MM OR 590-600 MM X 590-600 MM OR GREATER SIZED AS DIRECTED BY EIC) OF APPROVED QUALITY, SHADE AND PATTERN FOR FLOORING IN REQUIRED POSITION LAID ON A BED OF CEMENT MORTAR 1:4 INCLUDING CEMENT FLOAT JOINT FILLING WITH WHITE/COLOUR CEMENT SLURRY, CLEANING, CURING INCLUDING MAKING EXISTING FLOOR SUITABLE TO FIX NEW TILES IN PROPER LEVEL ETC. COMPLETE AS INSTRUCTED BY EIC.

800

-

1600

... More
PROVIDING AND LAYING MIRROR / GLOSSY / MATT FINISH VITRIFIED TILES OF SOMANY / RAK / KAJARIA / NITCO / JHONSON (300 MM X 300 MM OR 590-600 MM X 590-600 MM OR GREATER SIZED AS DIRECTED BY EIC) OF APPROVED QUALITY, SHADE AND PATTERN FOR DADO AND SKIRTING IN REQUIRED POSITION LAID ON A BED OF CEMENT MORTAR 1:4 INCLUDING CEMENT FLOAT JOINT FILLING WITH WHITE/COLOUR CEMENT SLURRY, CLEANING, CURING INCLUDING MAKING EXISTING FLOOR SUITABLE TO FIX NEW TILES IN PROPER LEVEL ETC. COMPLETE AS INSTRUCTED BY EIC.

25

-

1675

... More
PROVIDING WATER PROOF BEDDING FOR FLOORING OF BATH AND WC 25 MM THICK IN C.M. 1:3 INCLUDING USING APPROVED WATER PROOFING COMPOUND IN SPECIFIED PROPORTION AS PER MANUFACTURERS SPECIFICATIONS FOR PER BAG OF CEMENT INCLUDING LEVELING, CURING ETC. COMPLETE.

180

-

430

... More
PROVIDING AND LAYING ANTISKID CERAMIC TILES OF APPROVED QUALITY OF SIZE 30 CM X 30 CM FOR ANTISKID FLOORING IN REQUIRED POSITION LAID ON A BED OF 1:4 CEMENT MORTAR INCLUDING CEMENT FLOAT, FILLING JOINT WITH CEMENT SLURRY CLEANING CURING ETC. COMPLETE.

200

-

1200

... More
PROVIDING & FIXING COUNTER TOP WASH BASIN OF PARRYWARE/HINDWARE/ JAQUAR/CERA MAKE & OF APPROVED COLOR WITH ITS FITTINGS INCLUDING BRASS WASTE COUPLING, SS BOTTLE TRAP, CP PILLAR TAP (JAQUAR/PLUMBER MAKE), CONNECTOR FOR ANGEL COCK, CP HEAVY QUALITY ANGLE STOP COCK, ETC. COMPLETE SO AS TO MAKE IT FIT TO USE.

5

-

5599

... More
PROVIDING AND FIXING WHITE GLAZED EARTHENWARE SQUATTING PLATE (LADIES URINAL) WITH P.V.C. FLUSHING CISTERN OF 5 LITERS CAPACITY WITH FITTING, INLET PIPES AND STOP TAP, BRACKETS FOR FIXING THE CISTERN, 32 MM DIA. P.V.C FLUSH PIPE WITH FITTINGS AND FLUSHING ARRANGEMENT INCLUDING LEAD SOIL PIPE, LEAD TRAP, SOIL PIPE CONNECTIONUP TO THE OUTSIDE FACE OF THE WALL

5

-

4173

... More
PROVIDING & FIXING OF PROCELAIN CHINA WARE URINAL 635 X 395X 420 OF PARRYWARE / HINDWARE/ JAQUAR/CERA MAKE INCLUDING BRACKET AND ALL REQUIRED MATERIAL ETC. PVC OUTLET FOR URINAL OF SIZE 32MM DIA. CP DOOM TYPE WASTE COUPLING FOR URINAL ETC. COMPLETE. URINAL BRACKET, CP AUTO CLOSING ANGLE COCK, CP SPREADER CONNECTION FOR URINAL ETC. CP CONNECTOR FOR URINAL ETC. COMPLETE.

5

-

9774

... More
PROVIDING AND FIXING WALL HUNG / FLOOR MOUNTED EUROPEAN TYPE WHITE GLAZED EARTHENWARE WATER CLOSET PAN OF OF PARRYWARE / HINDWARE/ JAQUAR/CERA MAKE WITH ITS FITTINGS, 4" DIA. PVC BEND PIPE, M.S.BRACKETS, SOFT CLOSER SEAT, GROHE MAKE PNEUMATIC FLUSH TANK, 2 WAY BIB COCK WITH HEALTH FAUSCET, ETC. WITH CHROMIUM PLATED BRASS HINGES AND RUBBER BUFFERS INCLUDING UPVC AND VENT PIPE UP TO THE OUTSIDE FACE OF WALL WITH FITTINGS PIPE, BRACKETS FOR FIXING CISTERN 32 MM DIA. UPVC FLUSH PIPE WITH FITTINGS AND CLAMPS, 20 MM DIA. UPVC OVERFLOW PIPE, MOSQUITO PROOF COUPLINGS, WITH WATER JET AND FITTING INCLUDING CUTTING AND MAKING GROOVE TO THE WALLS AND FLOORS TESTING ETC. COMPLETE SO AS TO MAKE IT FIT TO USE.

5

-

11200

... More
PROVIDING & FIXING CONCEALED / CLAMPED ON WALL ASTRAL/FINOLEX OR EQUIVALENT MAKE CPVC PIPE IN TOILETS WITH NECESSARY FITTINGS LIKE ELBOW, UNIONS, PLUG, PVC INSULATION PIPE & OTHER HARDWARE AND MAKING ALL PIPES LEAK PROOF INCLUDING PLUMBING LINES FOR BELOW MENTION SANITARY FITTINGS FOR 15 MM DIA.

5

-

266

... More
PROVIDING & FIXING CONCEALED / CLAMPED ON WALL ASTRAL/FINOLEX OR EQUIVALENT MAKE CPVC PIPE IN TOILETS WITH NECESSARY FITTINGS LIKE ELBOW, UNIONS, PLUG, PVC INSULATION PIPE & OTHER HARDWARE AND MAKING ALL PIPES LEAK PROOF INCLUDING PLUMBING LINES FOR BELOW MENTION SANITARY FITTINGS FOR 20 MM DIA.

5

-

310

... More
PROVIDING & FIXING CONCEALED / CLAMPED ON WALL ASTRAL/FINOLEX OR EQUIVALENT MAKE CPVC PIPE IN TOILETS WITH NECESSARY FITTINGS LIKE ELBOW, UNIONS, PLUG, PVC INSULATION PIPE & OTHER HARDWARE AND MAKING ALL PIPES LEAK PROOF INCLUDING PLUMBING LINES FOR BELOW MENTION SANITARY FITTINGS FOR 25 MM DIA.

5

-

375

... More
PROVIDING & FIXING CONCEALED / CLAMPED ON WALL ASTRAL/FINOLEX OR EQUIVALENT MAKE CPVC PIPE IN TOILETS WITH NECESSARY FITTINGS LIKE ELBOW, UNIONS, PLUG, PVC INSULATION PIPE & OTHER HARDWARE AND MAKING ALL PIPES LEAK PROOF INCLUDING PLUMBING LINES FOR BELOW MENTION SANITARY FITTINGS FOR 32 MM DIA.

5

-

431

... More
PROVIDING & FIXING CONCEALED / CLAMPED ON WALL ASTRAL/FINOLEX OR EQUIVALENT MAKE UPVC PIPE IN TOILETS WITH NECESSARY FITTINGS LIKE ELBOW, UNIONS, PLUG, PVC INSULATION PIPE & OTHER HARDWARE AND MAKING ALL PIPES LEAK PROOF INCLUDING PLUMBING LINES FOR BELOW MENTION SANITARY FITTINGS FOR 15 MM DIA.

25

-

245

... More
PROVIDING & FIXING CONCEALED / CLAMPED ON WALL ASTRAL/FINOLEX OR EQUIVALENT MAKE UPVC PIPE IN TOILETS WITH NECESSARY FITTINGS LIKE ELBOW, UNIONS, PLUG, PVC INSULATION PIPE & OTHER HARDWARE AND MAKING ALL PIPES LEAK PROOF INCLUDING PLUMBING LINES FOR BELOW MENTION SANITARY FITTINGS FOR 20 MM DIA.

5

-

289

... More
PROVIDING & FIXING CONCEALED / CLAMPED ON WALL ASTRAL/FINOLEX OR EQUIVALENT MAKE UPVC PIPE IN TOILETS WITH NECESSARY FITTINGS LIKE ELBOW, UNIONS, PLUG, PVC INSULATION PIPE & OTHER HARDWARE AND MAKING ALL PIPES LEAK PROOF INCLUDING PLUMBING LINES FOR BELOW MENTION SANITARY FITTINGS FOR 25 MM DIA.

5

-

355

... More
PROVIDING & FIXING CONCEALED / CLAMPED ON WALL ASTRAL/FINOLEX OR EQUIVALENT MAKE UPVC PIPE IN TOILETS WITH NECESSARY FITTINGS LIKE ELBOW, UNIONS, PLUG, PVC INSULATION PIPE & OTHER HARDWARE AND MAKING ALL PIPES LEAK PROOF INCLUDING PLUMBING LINES FOR BELOW MENTION SANITARY FITTINGS FOR 32 MM DIA.

5

-

412

... More
PROVIDING AND FIXING 15 CM RIGID PVC NAHANI TRAP INCLUDING PVC GRATING ,BEND,CONNECTINGPIECE OF UPVC PIPE UP TO THE OUTSIDE FACE OF WALL ,MAKING THE GOOD DAMAGED SURFACE AND TESTING ETC. COMPLETE ( PRIOR APPROVAL OF SAMPLE AND BRAND BY EX. ENGR. IS NECESSARY BEFORE USE)

5

-

571

... More
PROVIDING AND FIXING 100 MM RIGID PVC NAHANI TRAP INCLUDING PVC GRATING, BEND, CONNECTING PIECE OF UPVC PIPE UP TO OUTSIDE FACE OF WALL AND OTHER NECESSARY FITTINGS ETC. COMPLETE AS DIRECTED BY EIC.

15

-

539

... More
PROVIDING AND FIXING 15 MM DIA. 2 IN 1 BIB COCK OF BRASS INCLUDING NECESSARY SOCKETS/UNION NUT COMPLETE.

10

-

775

... More
PROVIDING AND FIXING 15 MM DIA. ANGLE COCK OF BRASS INCLUDING NECESSARY SOCKETS/UNION NUT COMPLETE.

10

-

485

... More
PROVIDING AND FIXING S.S. JALI OF ROUND 5" (PLAIN) OVER NAHANI TRAP INCLUDING NECESSARY SOCKETS/UNION NUT COMPLETE.

10

-

42

... More
PROVIDING AND FIXING 15 MM DIA. CONCEALED STOP COCK OF BRASS INCLUDING NECESSARY SOCKETS/UNION NUT COMPLETE.

10

-

750

... More
PROVIDING AND FIXING 15 MM DIA. MIXER COCK OF BRASS INCLUDING NECESSARY SOCKETS/UNION NUT COMPLETE.

10

-

3400

... More
PROVIDING AND FIXING BRASS PILLAR, STOP TAP OR REGULAR TAP WITH NECESSARY FITTINGS OF SEIKO/PLUMBER OR OF EQUIVALENT MAKE AS APPROVED BY EIC.

10

-

400

... More
PROVIDING AND FIXING P.V.C. RAIN WATER PIPES OF 110MM OUTER DIAMETER AND HAVING WALL THICKNESS OF 2.2 TO 2.7 MM CONFIRMING TO I.S. 13592-1992 INCLUDING PROPER RAINWATER RECEIVING RECESS WITH P.V.C. PLUG, BEND, NECESSARY FITTINGS, SUCH AS, OFFSETS, SHOES, INLUDING FIXING THE PIPE ON WALL USING APPROVED WOODEN CLEATS PROJECTING 25MM TO 40MM FROM FACE OF WALL A FIXING WITH CLIPS OF APPROVED QUALITY AND ONE NUMBER ,FILING THE JOINT USING RUBBER GASKET WITH SOLVENT CEMENT AND PROPERLY RESTING THE SHOE OF PIPES ON C.C. OR MASONRY BLOCKS, INCLUDING NECESSARY SCAFFOLDING AND MAINTENANCE FOR 3 YRS FOR ANY LEAKAGES OR DISLOCATIONS OF PIPES. ALL THE P.V.C. FITTINGS AND ADDITIONAL 2 PIECE SOCKET CLIPS SHALL BE GOT APPROVED FROM ENGINEER IN CHARGE ETC. COMPLETE.

25

-

569

... More
PROVIDING AND APPLYING LIQUID ELASTOMERIC POLYMERIZED BITUMINOUS MEMBRANE WATERPROOFING TREATMENT WITH BRUSH APPLIED SINGLE COMPONENT, WATER BASED, COLD APPLIED (TARFELT LM OR EQUIVALENT) INCLUDING CLEANING THE SURFACE AND MADE FREE OF DIRT, DUST, LAITANCE ETC. THE RATE IS INCLUSIVE OF ONE COAT OF PRIMER @0.2 KG/SQM AND TWO COAT OF LIQUID MEMBRANE COATING @ 0.50 KG/SQM FOR TWO COAT ETC. COMPLETE AS PER MANUFACTURE'S SPECIFICATION.

1300

-

264

... More
PROVIDING AND LAYING PLAIN FINISH AAP (ATACTIC POLYPROPYLENE POLYMER) POLYMER MODIFIED BITUMINOUS MEMBRANE 3 MM. THICK (WT: 3.5 TO 4.0 KG/SQM) BLACK FINISHED REINFORCED WITH NON WOVEN POLYSTER MATT BY SAME MEMBRANE MANUFACTURER OF FOR WATER-PROOFING OF TERRACE SLAB AND RCC SURFACES AFTER APPLICATION OF COMPATIBLE MODIFIED BITUMINOUS PRIMER @ MIN. 0.25 LTR/SQM AS PER MANUFACTURER'S SPECIFICATIONS, TO SLAB WITH ALL LEADS AND LIFTS WITH TRANSVERSE LAPPING OF MIN 75 MM. & LONGITUDINAL LAPPING OF MIN 150 MM. ETC. COMPLETE, LAYER OF PMB MEMBRANE SHALL BE LAID BY USING BUTANE TORCH AND SEALING ALL JOINT ETC. AND PREPARING THE SURFACE AS PER MANUFACTURER'S SPECIFICATIONS AS DIRECTED BY EIC WITH THE FOLLOWING SPECIFICATIONS OF THE MEMBRANE : 1. LONGITUDINAL & TRANSVERSE TENSILE STRENGTH OF MIN 600N & 400N/SCM. LENGTH AT 23 C. 2. LONGITUDINAL & TRANSVERSE TEAR STRENGTH OF MIN 300N & 2500N/SCM. LENGTH AT 23 C. 3. SOFTENING POINT OF NOT LESS THAN 150 C. 4. NON FLOW HEAT RESISTANCE OF NOT LESS THAN 1000 C. 5. COLD FLEXIBILITY OF UP -20 C WHEN TESTED IN ACCORDANCE WITH ASTM, D-5147 PRIMER SHALL HAVE DENSITY.

5000

-

371

... More
PROVIDING AND LAYING CERAMIC TILES HAVING SIZE 30 CM. X 45 CM. CONFIRMING TO CORRESPONDING I.S. FOR DADO AND SKIRTING IN REQUIRED POSITION WITH READYMADE ADHESIVE MORTAR OF APPROVED QUALITY ON PLASTER OF 1:2 CEMENT MORTAR INCLUDING JOINT FILLING WITH WHITE/ COLOUR CEMENT SLURRY CLEANING CURING ETC. COMPLETE.

1200

-

1278

... More
PROVIDING AND APPLYING POLYMER MODIFIED READY MIX CEMENT MORTAR (PMM) FOR PLASTERING/ MICRO CONCRETE (PMC) OF ANY THICKNESS AS PER SITE REQUIREMENT OF APPROVED BRAND INCLUDING CURING ETC. AS PER MANUFACTURER'S SPECIFICATIONS OR AS PER INSTRUCTIONS OF ENGINEER IN-CHARGE (THE ITEMS SHALL BE PAID ON ACTUAL CONSUMPTION OF READY MIX QUANTITY ONLY). THE RATE SHALL BE INCLUSIVE OF SURFACE PREPARATION BEFORE APPLICATION AS PER THE MANUFACTURER'S SPECIFICATIONS INCLUDING NECESSARY FORMWORK, APPLYING RUST CONVERTER, RUST INHIBITOR COAT, BOND COAT ETC. AS DIRECTED BY EIC AT ALL HEIGHTS INCLUDING M.S. PIPE SCAFFOLDING ETC. COMPLETE.

5

-

40000

... More
PROVIDING AND LAYING IN SITU CEMENT CONCRETE OF GRADE M-25 OF TRAP/ GRANITE /QUARTZITE/ GNEISS METAL (USING 20 MM NOMINAL GAUGE GRADED STONE AGGREGATE) FOR R.C.C. WORK IN PLINTHS BEAM, LINTELS, COLUMNS, PEDETSALS, WALLS/PARDIS, SLABS, LANDINGS, CHAJJA ETC. INCLUDING MAKING ARRANGEMENT FOR BAILING OUT OF ANY SEEPAGE WATER UNDERNEATH, DEWATERING, FORMWORK, COVER BLOCKS, COMPACTION AND CURING (EXCLUDING REINFORCEMENT AND STRUCTURAL STEEL) COMPLETE INCLUDING CENTERING, SHUTTERING, FINISHING SURFACES TO GIVE A SMOOTH AND EVEN SURFACE OR ROUGHENING IF SPECIAL FINISH TO BE PROVIDED ETC. COMPLETE IN ALL RESPECTS AS PER DIRECTION OF ENGINEER-IN-CHARGE. (MINIMUM CEMENT CONTENT SHALL NOT BE LESS THAN 410 KG/CUM.)

1

-

12452

... More
PROVIDING AND FIXING STEEL BAR REINFORCEMENT (TMT FE 500 ISI MARKED STEEL) OF VARIOUS DIAMETERS (CONFORMING TO IS CODE) FOR R.C.C. FOOTINGS, FOUNDATIONS, SLABS, BEAMS, COLUMNS, STAIRCASE, NEWELS, CHAJJAS, LINTELS, PARDIS, COPINGS, ARCHES ETC. AS PER DETAILED DESIGNS, DRAWINGS AND SCHEDULES INCLUDING CUTTING, BENDING, HOOKING THE BARS BINDING WITH WIRES, COVER BLOCK SUPPORTING, TACK WELDING AS REQUIRED ETC. COMPLETE. NO EXTRA PAYMENT SHALL BE MADE FOR 18 SWG ANNEALED BINDING WIRES, CHAIRS.

1

-

89703

... More
PROVIDING AND FIXING STAINLESS STEEL (GRADE 304) RAILING MADE OF HOLLOW TUBES, CHANNELS, PLATES ETC. INCLUDING WELDING GRINDING, BUFFING, POLISHING AND MAKING CURVATURE (WHEREVER REQUIRED) AND FITTING THE SAME WITH NECESSARY STAINLESS STEEL NUTS AND BOLTS COMPLETE, I/C FIXING THE RAILING WITH NECESSARY ACCESSORIES AND STAINLESS STEEL DASH FASTENERS, STAINLESS STEEL BOLTS, ETC. OF THE REQUIRED SIZE ON THE TOP OF THE FLOOR OF THE SIDE OF WAISTE SLAB WITH SUITABLE ARRANGEMENT AS PER APPROVAL OF ENGINEER IN CHARGE (FOR PAYMENT PURPOSE, ONLY THE WEIGHT OF THE STAINLESS STEEL MEMBERS SHALL BE CONSIDERED EXCLUDING FIXING ACCESSORIES SUCH AS NUT BOLTS, FASTENERS ETC.). 50MM DIA. PIPE, 1.5MM THICKNESS AND WEIGHT 1.92KILOGRAM/ R. METRE

15

-

694

... More
DEMOLISHING EXISTING BRICK / STONE MASONRY WORK IN CEMENT MORTAR (ANY PROPORTION AT ANY HEIGHTS / DEPTHS INCLUDING STACKING OF SERVICEABLE MATERIALS AND DISPOSAL OF UNSERVICEABLE WITHIN A LEAD OF 3 KM., COMPLETE AS DIRECTED BY ENGINEER-IN-CHARGE

2

-

335

... More
REMOVING EXISTING LOOSE CEMENT PLASTER/ CONCRETE OF ANY FINISH FROM THE WALL, COMPLETE INCLUDING PREPARING SURFACE, NECESSARY SCAFFOLDING, CLEANING ETC. COMPLETE INCLUDING DISPOSAL OF MATERIALS DEBRIS WITHIN RCF FACTORY PREMISES WITHIN A LEAD OF 3 KM., COMPLETE AS DIRECTED BY ENGINEER-IN-CHARGE.

625

-

52

... More
REMOVING DOORS AND WINDOWS WITH FRAMES AND STACKING THE MATRIALS AS DIRECTED WITH ALL LEADS, LIFTS ETC. COMPLETE.

200

-

156

... More
DEMOLISHING EXISTING PLAIN CEMENT CONCRETE WORK INCLUDING RCC, ETC. AT ALL HEIGHTS / DEPTHS INCLUDING DISPOSAL OF MATERIALS DEBRIS & SCRAP METAL WITHIN RCF FACTORY PREMISES WITHIN A LEAD OF 3 KM., COMPLETE AS DIRECTED BY ENGINEER-IN-CHARGE.

1

-

1451

... More
DISMANTLING FLOOR TILES/CHEQUERED TILES INCLUDING DISPOSAL OF MATERIALS DEBRIS & SCRAP METAL WITHIN RCF FACTORY PREMISES WITHIN A LEAD OF 3 KM., COMPLETE AS DIRECTED BY ENGINEER-IN-CHARGE.

1500

-

45

... More
REMOVING URINAL PANS / WASH HAND BASINS / WC PANS WITH FRAME INCLUDING DISCONNECTING THE SANITARY AND WATER SUPPLY CONNECTIONS, REMOVING THE SAME CAREFULLY AND STACKING THE SERVICEABLE MATERIALS AS AND WHERE DIRECTED ETC COMPLETE

25

-

96

... More
REMOVING IRON PIPE RALING HAVING WOODEN R.C.C. OR C.C. OR IRON POST AND STACKING THE MATERIALS AS DIRECTED ETC. COMPLETE.

25

-

69

... More
REMOVING EARTHEN, STONEWATE PIPE AND STACKING THEM AS DIRECTED WITH ALL LEADS, LIFTS ETC. COMPLETE.

5

-

22

... More
REMOVING CAST IRON OR WROUGHT IRON OR A.C. PIPE AND STACKING THEM AS DIRECTED WITH ALL LEADS, LIFTS ETC. COMPLETE.

15

-

22

... More
DISMANTLING THE R.C.C. WORK AND SORTING OUT THE MATERIALS SUCH AS STEEL ETC. AS DIRECTED AND STACKING THEM WITHIN THE SPECIFIED LEAD AS DIRECTED ETC. COMPLETE.

30

-

1451

... More
REMOVING THE TAR OR COBA OR BITUMINOUS MEMBRANE AND DISPOSING OF THE MATERIAL AS DIRECTED ETC. COMPLETE.

3000

-

26

... More
DISMANTLING OF EXISTING WATERPROOFING LAYERS OVERBURDEN IF ANY WITHOUT DAMAGING THE CONCRETE SURFACE OF RCC ROOF, INCLUDIING REMOVING SCALING ,STAINS OF OLD WATERPROOFING TREATMENT CLEANING THE ROOF CONCRETE SURFACE OF RCC ROOF BY MACHANICAL WIRE BRUSH ETC, LOWERING AND DISPOSAL OF THE DEBRIS TO THE SITE AS DIRECTED UPTO 3 KM LEAD WITH IN RCF PREMISES COMPLETE AS DIRECTED BY EIC.

500

-

16

... More
PROVIDING AND FIXING ONLY MISC. MATERIALS NOT COVERED IN THE SCHEDULE OF RATES MENTIONED ABOVE INCLUDING, FIXING AS DIRECTED BY EIC, STORAGE, TRANSPORTING, LOADING, UNLOADING AT SITE ETC. COMPLETE AS DIRECTED EIC AS PER REQUITREMENT OF JOB .(PAYMENT SHALL BE MADE ON BASIS OF ACTUAL COST OF MATERIAL PER GST-CASH MEMO/ RECEIPT-GST). 15% EXTRA PAYABLE TO THE CONTRACTOR TO COVER PROFIT AND OVERHEAD.

1.15

-

100000

... More
PROVIDING AND FIXING IN POSITION 0.50MM THICK CORRUGATED GALVALUME SHEETS, PLANE RIDGES, PLANE CORNERS, PLANE BOUNDRY GUTTERS ETC. OF APPROVED COLOUR & DESIGN OF APPROVED MAKE FOR ROOFING/CLADDING (550 MPA & AZ150 COATING) INCLUDING NECESSAARY FITTINGS, FASTNINGS & PACKINGS FOR SLOPE TO DRAIN AS PER MANUFACTURER'S SPECIFICATIONS AT ALL HEIGHTS. COMLETE AS DIRCTED BY ENGINEER IN CHARGE.

100

-

577

... More
PROVIDING AND FIXING ANODIZED ( TRANSPARENT OR DYED TO REQUIRED SHADE ACCORDING TO IS: 1868. MINIMUM ANODIC COATING OF GRADE AC 15) ALUMINUM SECTIONS FOR FIXED/ SLIDING / PIVOTED / TOP HUNG / SIDE HUNG / LOUVERED TYPE WINDOWS, DOORS, VENTILATORS AND PARTITIONS CONFORMING TO IS:1948, 1961 WITH HOLLOW BOTTOM SECTION & STANDARD SINGLE / TWO / THREE / FOUR TRACK FRAME SECTION ALL ROUND (TOP, BOTTOM AND SIDES) WITH SHUTTER FRAME MADE UP OF STANDARD HANDLE SECTIONS STANDARD INTERLOCKING SECTION AND STANDARD TOP AND BOTTOM SECTION WITH IN FILL PANEL OF PLAIN FROSTED / TINTED GLASS/ NOVAPAN SHEET / ACRYLIC SHEET / HARDNER LAMINATED SHEET AS LISTED BELOW WITH NYLON GUIDES, GLIDERS GLASS FIXING PVC WEATHER STRIPS, NEOPRENE GASKET, PVC WEEP HOLES ETC. COMPLETE WITH APPROVED TYPE OF LOCKING ARRANGEMENT, HANDLES AND OTHER FIXTURES INCLUDING FIXING, FILLING THE GAPS WITH SILICON SEALANT, CLEANING POLISHING THE ALUMINIUM SECTION WITH PETROL AND / OR OTHER AGENTS AS SPECIFIED BY THE MANUFACTURERS ETC. COMPLETE AS DIRECTED BY ENGINEER IN CHARGE. GLAZING WORK / NOVAPAN / HARDNER / ACRYLIC SHEET SHALL BE PAID SEPARATELY UNDER RESPECTIVE ITEM.

1205

-

639

... More
SUPPLYING FABRICATING & ERECTING IN POSITION BOLTED AND/ OR WELDED HOT DIPPED GALVANIZED GRATING IN WALKWAYS, PLATFORMS ETC. (FABRICATED AS PER STANDARD DRAWING)MADE OUT OF CONTRACTORS OWN MS PLATES, CHEQUERED PLATE, MS FLATS, HSD REINFORCEMENT BARS INCLUDING CUTTING OF REQUIRED SIZE, SHAPE, MAKING HOLE OF REQUIRED SIZE, MAKING THE EDGES SMOOTH, GETTING IT HOT DIP GALVANISED AFTER FABRICATION, ERECTING USING GI CLAMPS, NUT BOLTS AND WASHERS ETC. ALL COMPLETE. NOTE: 1) ALL MATERIAL TO BE SUPPLIED BY THE CONTRACTOR. 2) HSD REINFORCEMENT SHALL CONFIRM TO IS:1786 FE415 AND MS PLATES/ CHEQUERED PLATE/ MS FLAT SHALL CONFIRM TO IS:2062. 3) HOT DIP GALVANISING SHALL BE OF 80 to 90 MICRONS THICKNESS 4) PAYMENT FOR G.I. GRATINGS SHALL BE MADE AS PER THE ACTUAL PHYSICAL WEIGHT OF THE G.I. GRATING AS OBTAINED AT SITE. WEIGHMENT AT RCF WEIGH-BRIDGE SHALL BE NECESSARY. 5) THIS INCLUDES SUPPLYING, FABRICATING & ERECTING IN POSITION BOLTED AND/ OR WELDED HOT.( APPROXIMATE WEIGHT OF GRATING SHALL BE 35 TO 40 KG/SQ.)

2

-

120000

... More
PROVIDING, AND FIXING ALUMINIUM COMPOSITE PANEL 3MM THICK WITH SHEET OF APPROVED QUALITY AND MAKE (VIVA OR EURO BOND OR EQUIVALENT MAKE) IN PLAIN CLEAR OR ANY APPROVED COLOUR WITH HEAVY SECTIONAL ALUMINUM FRAME WORK AND CLADDING COMPOSITE WITH SILICON INCLUDING PROVIDING SCAFFOLDING AND INSTALATION IN PROPER LINE AND LEVEL COMPLETE AS DIRECTED BY ENGINEER IN CHARGE.

300

-

3520

... More
PROVIDING AND LAYING VITRIFIED MIRROR/GLOSSY FINISH HAVING DECORATIVE TYPE OF SIZE 590 MILLIMETER TO 605 MILLIMETER X 590 MILLIMETER TO 605 MILLIMETER OF 8 TO 10 MILLIMETER THICKNESS (ON A EXISTING FLOORING) WITH BONDING CHEMICAL OF APPROVED MAKE SHADE AND PATTERN FOR FLOORING IN REQUIRED POSITION LAID ON A BED OF BONDING CHEMICAL FILLING JOINTS CURING AND CLEANING ETC . COMPLETE.

800

-

1217

... More
HEALTH ASSESMENT OF SCHOOL BUILDING STRUCTURE AND ISSUE OF STABILITY CERTIFICATE IN RCF FORMAT FOR MINIMUM FIVE YEARS BY COMPETENT AUTHORITY- LISCENSED CHARTER STRUCTURAL ENGINEER. DETAILED STRUCTURAL REPORT SHALL BE SUBMITTED WHICH SHALL INCLUDE PHOTOGRAPHIC EVIDENCE, NECESSARY TEST LIKE NDT'S, REBOUND HAMMER TEST. IF REQUIRED CORE EXTRACTION, CARBONATION TEST ON SITU CONCRETE, CHEMICAL ANALYSIS (PH, CHLORIDE CONTENT, SULPHATE CONTENT ETC), CONDITION OF REINFORCEMENT, ANALYSIS OF TESTS, INTERPRITATION OF TEST, CONFIRMATION OF RESIDUAL STRENGTH ETC.

1

-

10000

... More
POINT WIRING FOR LIGHTING :PRIMARY LIGHT POINT WIRING (2.5 SQMM) (MAIN SWITCH BOARD TO SWITCH BOX & SWITCH BOX TO FIRST LIGHT POINT) THROUGH 20/25 MM HMS PVC CONDUIT WITH ALL REQUIRED ACCESSORIES LIKE 2 NOS OF 2.5 SQMM & 1 NO OF 2.5 SQMM ( FOR EARTH) COLOR RED, BLACK & GREEN PVC INSULATED COPPER FRLS WIRES WITH MODULAR TYPE SWITCHES COMPLETE WITH ALL ACCESSORIES AS REQUIRED. THE SWITCH BOXES SHALL BE FLUSH MOUNTED WITH PARTITION WORKS OR AS DIRECTED BY THE ARCHITECTS AND SHALL BE DONE IN CO-ORDINATION WITH INTERIOR FURNITURE WORKS. THE RATE SHALL INCLUDE CIRCUIT WIRING FRLS FROM MAIN DB TO SWITCHBOARD & FRLS FROM SWITCHBOARD TO SWITCHBOARD. CONDUIT SHALL BE FIXED ON WALL / TRAYS OR CEILING WITH SPACERS & SADDLES. THE WIRES WILL BE TERMINATED IN A SEPARATE CONNECTOR BEFORE FIXTURES. APPROVED MAKES:-CONDUITS-PRECISION/DIAMOND, WIRES-FINOLEX/POLYCAB/BONTON, SWITCHES-ANCHOR

51

-

757.72

... More
SECONDARY LIGHT POINT WIRING (1.5 SQMM) (FIRST LIGHT POINT TO SECOND LIGHT POINT) THROUGH 20/25 MM HMS PVC CONDUIT WITH ALL REQUIRED ACCESSORIES LIKE 2 NOS OF 1.5 SQMM & 1 NO OF 1.5 SQMM ( FOR EARTH) COLOR RED, BLACK & GREEN PVC INSULATED COPPER FRLS WIRES AS DIRECTED BY THE ARCHITECTS AND SHALL BE DONE IN CO-ORDINATION WITH INTERIOR FURNITURE WORKS. THE RATE SHALL INCLUDE CIRCUIT WIRING (FRLS WIRES) FROM FIRST LIGHT POINT TO SECOND LIGHT POINT & CONDUIT SHALL BE FIXED ON WALL / TRAYS OR CEILING WITH SPACERS & SADDLES. THE WIRES WILL BE TERMINATED IN A SEPARATE CONNECTOR BEFORE FIXTURES. APPROVED MAKES:-CONDUITS-PRECISION/DIAMOND, WIRES-FINOLEX/POLYCAB/BONTON.

300

-

421.26

... More
SECONDARY (1/2 POINT) POINT, 6 AMP. ON SAME SWITCH BOARD WITH ACCESSORY LIKE 6 AMP. MODULAR SWITCH & 6 AMP. MODULAR SOCKET (5 PIN). MAKE - ANCHOR.

26

-

162.59

... More
SECONDARY (1/2 POINT) POINT, 16 AMP. ON SAME SWITCH BOARD WITH ACCESSORY LIKE 16 AMP. MODULAR SWITCH & 16 AMP. MODULAR SOCKET (5 PIN). MAKE - ANCHOR.

10

-

216.8

... More
SUPPLY & INSTALLATION OF MODULAR ELCB/RCCB IN MAIN LIGHTING SWITCH BOARD (6A/10 A, 30 MA ) MAKE - ANCHOR

30

-

3833.71

... More
POWER POINT WIRING FOR POWER POINT - POINT WIRING THROUGH ALREADY LAID FLOOR RACEWAYS & CONDUITS WITH ALL REQUIRED ACCESSORIES LIKE 2 NOS OF 2.5 SQMM & 1 NO OF 2.5 SQMM ( FOR EARTH) COLOR RED, BLACK & GREEN PVC INSULATED COPPER FRLS WIRES WITH 1 NOS OF 6 AMP. SWITCH & 1 NO. 6 AMP SOCKET (5 PIN) MODULAR TYPE SWITCHES AND SOCKETS COMPLETE WITH ALL ACCESSORIES AS REQUIRED. THE SWITCH BOXES SHALL BE FLUSH MOUNTED WITH PARTITION WORKS OR AS DIRECTED BY THE ARCHITECTS AND SHALL BE DONE IN CO-ORDINATION WITH INTERIOR FURNITURE WORKS. THE RATE SHALL INCLUDE CIRCUIT WIRING FRLS FROM MAIN DB TO SWITCHBOARD FOR RAW POWER. APPROVED MAKES:-CONDUITS-PRECISION/DIAMOND, WIRES-FINOLEX/POLYCAB/BONTON, SWITCHES-ANCHOR

35

-

1192.41

... More
POWER POINT WIRING FOR POWER POINT - POINT WIRING THROUGH ALREADY LAID FLOOR RACEWAYS & CONDUITS WITH ALL REQUIRED ACCESSORIES LIKE 2 NOS OF 2.5 SQMM & 1 NO OF 2.5 SQMM ( FOR EARTH) COLOR RED, BLACK & GREEN PVC INSULATED COPPER FRLS WIRES WITH 1 NOS OF 16 AMP. SWITCH & 1 NO. 16 AMP SOCKET (5 PIN) MODULAR TYPE SWITCHES AND SOCKETS COMPLETE WITH ALL ACCESSORIES AS REQUIRED. THE SWITCH BOXES SHALL BE FLUSH MOUNTED WITH PARTITION WORKS OR AS DIRECTED BY THE ARCHITECTS AND SHALL BE DONE IN CO-ORDINATION WITH INTERIOR FURNITURE WORKS. THE RATE SHALL INCLUDE CIRCUIT WIRING FRLS FROM MAIN DB TO SWITCHBOARD FOR RAW POWER. APPROVED MAKES:-CONDUITS-PRECISION/DIAMOND, WIRES-FINOLEX/POLYCAB/BONTON, SWITCHES-ANCHOR

30

-

867.21

... More
SUPPLY & INSTALLATION OF MODULAR ELCB/RCCB IN MAIN COMPUTOR SWITCH BOARD (10A, 30 MA/16 A, 30 MA ) MAKE - ANCHOR

25

-

1530.78

... More
POWER POINT WIRING FOR AIRCONDITIONS - POINT WIRING THROUGH 20/25MM DIA MG PVC CONDUIT WITH ALL REQUIRED ACCESSORIES LIKE 2 NOS OF 4 SQMM & 1 NO OF 4 SQMM ( FOR EARTH) COLOR RED, BLACK & GREEN PVC INSULATED COPPER FRLS WIRES WITH 1 NOS OF 20 AMP. ELCB (100MA) & 1 NO. 20 AMP SOCKET (5 PIN) MODULAR TYPE SWITCHES AND SOCKETS COMPLETE WITH ALL ACCESSORIES AS REQUIRED. THE SWITCH BOXES SHALL BE FLUSH MOUNTED WITH PARTITION WORKS OR AS DIRECTED BY THE ARCHITECTS AND SHALL BE DONE IN CO-ORDINATION WITH INTERIOR FURNITURE WORKS. THE RATE SHALL INCLUDE CIRCUIT WIRING FRLS FROM MAIN DB TO SWITCHBOARD FOR RAW POWER. APPROVED MAKES:-CONDUITS-PRECISION/DIAMOND, WIRES-FINOLEX/POLYCAB/BONTON, SWITCHES-ANCHOR

10

-

1734.42

... More
POWER POINT WIRING FOR WATER COOLER - POINT WIRING THROUGH 20/25MM DIA MG PVC CONDUIT WITH ALL REQUIRED ACCESSORIES LIKE 2 NOS OF 4 SQMM & 1 NO OF 4 SQMM ( FOR EARTH) COLOR RED, BLACK & GREEN PVC INSULATED COPPER FRLS WIRES WITH 1 NOS OF 10 AMP. ELCB (30MA) & 1 NO. 20 AMP SOCKET (5 PIN) MODULAR TYPE SWITCHES AND SOCKETS COMPLETE WITH ALL ACCESSORIES AS REQUIRED. THE SWITCH BOXES SHALL BE FLUSH MOUNTED WITH PARTITION WORKS OR AS DIRECTED BY THE ARCHITECTS AND SHALL BE DONE IN CO-ORDINATION WITH INTERIOR FURNITURE WORKS. THE RATE SHALL INCLUDE CIRCUIT WIRING FRLS FROM MAIN DB TO SWITCHBOARD FOR RAW POWER. APPROVED MAKES:-CONDUITS-PRECISION/DIAMOND, WIRES-FINOLEX/POLYCAB/BONTON, SWITCHES-ANCHOR

2

-

1613.77

... More
SUPPLY AND LAYING RACEWAYS / CONDUITS (FOR UNDER FLOOR TRENCHES/ON TRAYS) ON EXISTING FOLLRING. RACEWAYS/CONDUITS SHALL BE FIXED TO THE FLOORING WITH GI CLAMPS FOR FINISHED LEVELS AS PER THE SITE CONDITIONS OR THROUGH PARTITIONS WITH ALL ACESSORIES. THE RATE SHALL PREPARATION OF TRENCHES UPTO 22" WIDE BY CAREFULLY REMOVING THE FLOOR TILES & MALWA BELOW THE TILES FOR ;AYING RACEWAYS.CONDUITS FOR POWER, TELEPHONES ETC. THE DEPTHOF THE TRENCHES SHALL BE AT LEAST 2 INCHES FROM THE FINISHED FLOOR LEVEL OR UPTO RCC OF THE SLAB. THE RATE SHALL INCLUDE THE ACTIVITY OF CLEARING THE DEBRIS GENERATED FROM THE PREPARATION OF TRENCHES & FILLING THE SAME WITH PCC 1:2:3 FOR THE PORTION WITHOUT FALSE FLOORING), APPROVED MAKES : GEETA.JINDAL. SIZE 80MM X 38MM X2MM THICK RECTANGULAR ALUMINUM SECTION FOR ROUTING OF ELECTRICAL, DATA & VOICE CABLES AS SPEFIFIED.

800

-

271

... More
SUPPLY & LAYING OF RIGID HG PVC CONDUITS FOR LIGHT / POWER POINT , SIZE 25 MM, MAKE - PRECISION / DIAMOND.

501

-

54.12

... More
SUPPLY & LAYING OF RIGID HG PVC CONDUITS FOR LIGHT / POWER POINT , SIZE 20 MM, MAKE - PRECISION / DIAMOND.

500

-

43.25

... More
SUPPLY AND LAYING OF SHEET STEEL FABRICATED METAL JUNCTION BOXES WITH KNOCKOUT HOLES ON THE SIDE WALLS OF THE BOX AND STAINLESS STEEL COVER OF 2.3/3 MM THICKNESS WITH A GASKET TO MAKE THE INSTALLATION WATER PROOF. JUNCTION BOXES SHALL BE FABRICATED FROM 16 GAUGE CRCA SHEETS DULY PAINTED WITH TWO COATS OF RED OXIDE PRIMER AND TWO COATS OF SYNTHETIC ENAMEL PAINT AND SHALL BE PROVIDED AT SUITABLE LOCATIONS SO THAT THE CABLES MAY BE PULLED OR REPLACED OF ADDITIONAL CABLES MAY BE PULLED WHENEVER REQUIRED IN FUTURE. COVER FOR THE TRUNKING SHALL ALSO BE FABRICATED AS ABOVE AND SHALL BE FIXED WITH RUST PROOF BRASS COUNTER SUNK LEVELER TYPE SCREWS. SIZE 300MM X 300MM X 50MM

30

-

542

... More
SUPPLY AND LAYING OF SHEET STEEL FABRICATED METAL JUNCTION BOXES WITH KNOCKOUT HOLES ON THE SIDE WALLS OF THE BOX AND STAINLESS STEEL COVER OF 2.3/3 MM THICKNESS WITH A GASKET TO MAKE THE INSTALLATION WATER PROOF. JUNCTION BOXES SHALL BE FABRICATED FROM 16 GAUGE CRCA SHEETS DULY PAINTED WITH TWO COATS OF RED OXIDE PRIMER AND TWO COATS OF SYNTHETIC ENAMEL PAINT AND SHALL BE PROVIDED AT SUITABLE LOCATIONS SO THAT THE CABLES MAY BE PULLED OR REPLACED OF ADDITIONAL CABLES MAY BE PULLED WHENEVER REQUIRED IN FUTURE. COVER FOR THE TRUNKING SHALL ALSO BE FABRICATED AS ABOVE AND SHALL BE FIXED WITH RUST PROOF BRASS COUNTER SUNK LEVELER TYPE SCREWS. SIZE 200MM X 200MM X 50MM

30

-

346.09

... More
SUPPLY & INSTALLATION OF 12 WAY MS DB WITH 32 A, 4 P, 440V, MCB (01 NOS) FOR INCOMMING SUPPLY AND 20A , SP MCB (08 NOS) FOR OUTGOING CIRCUIT INDOOR TYPE, WITH NEUTRAL & EARTHING BUS BAR (COMPLETE).

10

-

4216.56

... More
SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF INDOOR COMMERCIAL RECESS MOUNTED 1X36W LED LIGHT FIXTURE COMPLETE. APPROVED MAKES - WIPRO / PHILIPS/ HAVELLS / SYSKA

30

-

2396.74

... More
SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF INDOOR COMMERCIAL ROUND RECESS MOUNTED 1X20W LED LIGHT FIXTURE COMPLETE. APPROVED MAKES - WIPRO / PHILIPS/ HAVELLS / SYSKA

50

-

596.25

... More
SUPPLY AND INSTALLATION EXHAUST FAN 120MM SWEEP. APPROVED MAKE BAJAJ / HAVELLS / INDO

10

-

1625.49

... More
SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF LED TUBE LIGHT FITTING 20W, 4FT COMPLETE FIXTURE. APPROVED MAKES - WIPRO / PHILIPS/ HAVELLS / SYSKA

225

-

758.62

... More
LAYING, CLAMPING OF 4C X 16 SQMM, ALUMINIUM ARMOURED CABLE ON WALL / RACEWAY

400

-

206.4

... More
ESCAVATION CABLE TRENCHES OF SIZE (0.5X0.75XL ) WITH HALF ROUND CONTREAT PIPE SIZE 150 X 1000 MM FOR POWER CABLE

619

-

203.74

... More
LAYING OF 3.5C X 150 SQMM, ALUMINIUM ARMOURED CABLE IN ESCAVATED TRENCH

400

-

18.51

... More
SUPPLY OF 4C X 16 SQMM, 1100 V, ALUMINIUM ARMOURED CABLE

400

-

183.29

... More
SUPPLY OF 3.5C X 150 SQMM, 1100 V, ALUMINIUM ARMOURED CABLE

400

-

485.96

... More
SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF CALL BELL. APPROVED MAKES - ANCHOR / HAVELLS

5

-

215.02

... More
SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF EXHAUST FAN, 380 MM SWEEP, 1 PH, 230 V. MAKE- ALMONARD/ANCHOR/HAVELLS.

10

-

3818.98

... More
CABLE TERMINATION OF 3 ½ C X 16 SQ MM AL ARMORED CABLE WITH AL. LUGS, CABLE GLANDS, ETC.

15

-

451.02

... More
CABLE TERMINATION OF 3 ½ C X 150 SQ MM AL ARMORED CABLE WITH AL. LUGS, CABLE GLANDS, ETC.

10

-

676.54

... More
SUPPLY INSTALLATION TESTING & COMMISSIONING OF FOLLOWING MAIN PANEL SYSTEM: 415V AC, 3PH, 50HZ, FAULT LEVEL 50KA FOR 1-SEC.WIRING: THE WIRING WILL BE CARRIED OUT WITH 650/1100V GRADE PVC INSULATED STRANDED COPPER CONDUCTOR. CONTROL CIRCUIT: 1.5SMM.,C.T. CIRCUIT: 2.5SMM, SWITCH FUSE UNIT : 250A = 40 X 10CU, 125A = 35SQMM CU, CONSTRUCTION: FREE STANDING FLOOR/ WALL MOUNTING, NON-DRAWOUT & COMPARTMENTALIZED. FABRICATION: BASE: 5 X 75MM FABRICATED CHANNEL,FRAME: 14 SWG THICK CRCA SHEET STEEL.COVERS/ DOORS: 16 SWG THICK CRCA SHEET STEEL, DEGREE OF PROTECTION: IP-42. PAINTING: TWO COATS OF PRIMER & FINISH WITH EPOXY PAINT. BASED PAINT SHADE: EXTERNAL/ INTERNAL: SIEMENS GRAY 7032, SEMI GLOSSY. BASE CHANNEL: BLACK.CABLE ENTRY: BOTTOM/ TOP 3MM THICK CRCA SHEET STEEL DETACHABLE GLAND PLATE. BUSBARS: ELECTROLYTIC GRADE AL BUSBARES SUPPORTED ON SMC SUPPORTS. THE BUSBAR SYSTEM IS SUITABLE FOR 415V, 3PH, 50HZ WITH FAULT WITHSTANDING CAPACITY OF 50KA FOR 1S. HEAT SHRINKABLE PVC SLEEVES & COLOR CODE FOR PHASE IDENTIFICATION PROVIDED. EARTH BUSBAR: 1 X 40 X 10MM AL. MINIMUM BUSBAR CLEARANCES: PHASE TO PHASE: 25.4MM., PHASE TO NEUTRAL: 25.4MM, PHASE TO GROUND: 25.4MM, NEUTRAL TO GROUND: 19.4MM, LIVE PART TO GROUND: 19.4M. PANEL COMPRISES - INCOMING FEEDER: 250A, FP,SFU,36KA- 2 NOS. FOR INCOMMER 1 & 2. WITH INDICATING LED LAMPS R,Y,B WITH FUSES – 6 NOS., TWO (2) - MULTI DATA METER WITH THE FACILITY TO RECORD KILOWATTHOURS ( LOAD MANAGER ).MAKE: RISHABH/ MEGER / ELMEASURE, SIX (6) -250/5A, 10VA, CL 1.0, CTS, ALIMINIUM BUSBAR. OUTGOING FEEDERS :100A, 4P, SFU – 08NOS., 63A, 4P, SFU - 04 NOS. WITH BUSCOUPLER: 250A, FP, SFU ISOLATOR- 01 NO. SFU & ISOLATOR MAKE - L&T/HAVELLS/SCHNEIDER.

3

-

220099.87

... More
SUPPLY, INSTALLATION, CONNECTION, TESTING AND COMMISSIONING OF EARTHING STATION, AS PER SPECIFICATION AND IS: 3043 - 1985 FOR EQUIPMENT EARTHING WITH :EXCAVATION IN HARD MARRUM, WATERING PIPE, EARTHING STRIP / EARTHING CABLE, PLATE / PIPE ELECTRODE, HARDWARE, BRICK MASONRY CHAMBER WITH C.I. HINGED COVER AND FUNNEL, CHARCOAL AND SALT FILL, EQUIPOTENTIAL BAR, 600 X 600 X 3 MM. THICK CU.. EARTH ELECTRODE TYPE EARTH STATION.

5

-

9213.53

... More
PROVIDING AND LAYING EARTHING STRIP AS EARTHING CONDUCTOR INCLUDING NECESSARY ACCESSORIES, CLAMPING TO WALLS, CABLES ETC. AS REQUIRED AND INTERCONNECTION BETWEEN LENGHTS AS PER SPECIFICATIONS AND AS PER GOOD INSTALLATION PRACTICE. EARTHING BUSBAR SIZE OF 25X3 MM GI STRIP

500

-

405.79

... More
SMOKE DETECTOR FIXING AND COMMISSIONING

25

-

108.4

... More
REMOVING OF DB,OLD WIRING WITH ALL ACCESSORIES

25

-

446.88

... More
12 CORE SINGLE MODE OUTDOOR FIBER OPTIC CABLE OF 9/125 MICRON SPECIFICATION

300

-

80

... More
1U RACK MOUNT 24 PORT SC LOADED FIBER DISTRIBUTION UNIT(LIU) WITH ADAPTER STRIP AND COUPLERS, SPLICE TRAY

2

-

8500

... More
SC PIGTAIL SINGLE MODE 9/125

48

-

206.91

... More
LC-SC SINGLE MODE DUPLEX FIBER PATCH CORD OF 3 METER LENGTH

4

-

849.2

... More
UTP CAT 6E CABLE (300 M BOX)

15

-

7500

... More
UTP CAT 6E PATCH CORD OF 3 FEET LENGTH

50

-

650

... More
UTP CAT 6E PATCH CORD OF 7 FEET LENGTH

200

-

250

... More
UTP CAT 6E PATCH CORD OF 15 FEET LENGTH

50

-

450

... More
CAT 6E WALL MOUNT INFORMATION OUTLET WITH LOADED ONE RJ 45 PORT

100

-

199.1

... More
CAT 6E RJ 45 JACKS (1 BOX 100 NO. CONNECTORS)

1

-

544.5

... More
CAT 6E 48 PORT RJ 45 PATCH PANEL WITH LOADED UTP MODULES

2

-

6642.9

... More
9U NETWOK RACKS WITH WALL MOUNT ACCESSORIES

6

-

5500

... More
21 U FLOOR STANDING NETWORK RACK WITH FANS, WHEEL,TRAY & POWER ADAPTER STRIP FRONT AND BOTH SIDE DOOR OPENINGS

1

-

38500

... More
1 INCH PVC CONDUIT, T- JOINTS ACCESSORIES, COUPLERS ETC FOR FIXING

250

-

21

... More
30MM PERMANENT LUBRICATED HDPE DUCT(PLHDPE)

90

-

95

... More
OPTICAL FIBRE CABLE PULLING LAYING

200

-

35

... More
REMOVING OF FIBRE DISTRIBUTION UNIT

2

-

11

... More
OTDR TESTING OF FIBRE CABLE

48

-

200

... More
SPLICING OF SM OPTICAL CABLE

48

-

220

... More
UTP CABLE PULLING LAYING

4500

-

7.7

... More
REMOVAL OF EXISTING UTP CABLE

2000

-

3.3

... More
REMOVING 9U WALL MOUNT RACK

1

-

233.2

... More
FIXING OF 1 INCH PVC CONDUIT

250

-

7.7

... More
REMOVING OF EXISTING 1 INCH CASING CAPING /CONDUITS

100

-

3.3

... More
FIXING OF WALL MOUNT INFORMATION OUTLET AND PUNCHING BOTH END

100

-

27.72

... More
FIXING OF FIBRE DISTRIBUTION UNIT

2

-

275

... More
FIXING OF UTP PATCH PANEL

2

-

275

... More
RACEWAY JUNCTION BOX : RACEWAY FOR CABLE WORK AS PER DRAWING 4 HEAVY DUTY SECTION ALUMINIUM SIZE : 38 MM X80 MM X2MM THICK HEAVY DUTY SS (STAINLESS STEEL) FACE PLATE SIZE 300MM X 300 MM OR 500MM X500 MM AS PER REQUIREMENT

1

-

95000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.