Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Pune University - UOFP Tender
Eprocure
Opening Date31 Jul 2020
Closing DateCancelled
Tender AmountRefer Documents
Costs
EMD
₹ 58,000Document Cost
₹ 3,000Tender Fee
Refer Documents
Summary
Supply And Installation Of Hvac System For Athletic Pavilion Building At Sports Complex, Sppu, Pune(third Call)
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_UOFP_469097_3Bid Award Id
ViewTender No
CANO19-20/SPPU/EST/EE/ELCT/02Tender Authority
Pune University ViewPurchaser Address
-Website
http://www.unipune.ac.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
44 HP
2
-
-
In-door units - Supply, Installation, Testing & Commissioning of Ceiling Suspended Four Way Cassette (900mmx900mm) Type having efficient cooling unit and with full function corded remote control. Installation, testing & commissioning of factory built horizontal Ceiling mounted VRF based type units. a)Centrifugal fans, b)Coil section, c)Filter section, d)Insulated drain pan as detailed in specification.
-
-
-
3.33 TR
1
-
-
2.66 TR
3
-
-
2.33 TR
2
-
-
2.08 TR
1
-
-
1.66 TR
5
-
-
Supply, Installation, Testing & Commissioning of Ceiling Suspended Furred-In Unit Type having efficient cooling unit and with full function corded remote control. Installation, testing & commissioning of factory built horizontal Ceiling mounted VRF based type units. a)Centrifugal fans, b)Coil section, c)Filter section, d)Insulated drain pan as detailed in specification.
-
-
-
2.08 TR
1
-
-
1.66 TR
11
-
-
Supply, Installation, Testing & Commissioning of Kits for Floor Mounted Air Handling Units.
-
-
-
34.00 TR / 11,000 CFM
2
-
-
Supply, Installation, Testing & Commissioning of Remote control
-
-
-
Cordled remote control for cabins/ closed area
18
-
-
Supply, Installation, Testing & Commissioning of Refnets for connection between outdoor to Indoor .
24
-
-
Supply, Installation, Testing & Commissioning of Touch Screen Controller for VRV system for all the indoor & outdoor units installed at Ground floor With Necessary Cabling.
1
-
-
Supply, Installation, Testing & Commissioning of the following components of VRV system:- All refrigerant piping between indoor & outdoor Units duly insulated as per specifications.. Pipe line must be tested for requisite pressure & must be supported. All refrigerant piping to be insulated with 19 mm thick class "O" armaflex nitrile rubber & All exposed piping will be alluminum foil as per manufacturer.
-
-
-
6.35 - R410A
100
-
-
9.52 - R410A
70
-
-
12.70 - R410A
145
-
-
15.88 - R410A
50
-
-
19.05 - R410A
205
-
-
22.22 - R410A
25
-
-
25.40 - R410A
35
-
-
28.58 - R410A
65
-
-
31.75 - R410A
25
-
-
34.92 - R410A
50
-
-
38.10 - R410A
10
-
-
41.28 - R410A
145
-
-
Supply, Installation, Testing & Commissioning of All control cables between indoor and outdoor unit laid in PVC Piping and clamped .
-
-
-
2 Core 0.75/1 Sqmm Copper shielded Cable
601
-
-
3 Core 2.5 Sqmm Copper shielded Cable
91
-
-
Supply, Installation, Testing & Commissioning of All power cables with earthing between indoor and outdoor supported with M.S. Angles frame work (MCB/ELCB's provided 5m from Outdoor unit)
-
-
-
4 Core 10 Sqmm Copper shielded armoured cable
25
-
-
4 Core 16 Sqmm Copper shielded armoured cable
20
-
-
Supplying and erecting Iron, sheet metal work consisting of CRCA Sheets, Various sections of iron, Plates, Chequered Plates, Rods, Bars, MS pipes, etc. for panel board or any other purposes complete with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the Authority
900
-
-
Supply, Installation, Testing & Commissioning of PVC Drain piping for the unit with 6mm thick nitrile rubber insulation
-
-
-
50 mm Dia
15
-
-
40 mm Dia
50
-
-
32 mm Dia
50
-
-
25 mm Dia
95
-
-
Testing & Commissioning charges alongwith topping-up of refrigerant
95
-
-
Supply, Installation, Testing, Commissioning of Double Skin Floor Mounted Air Handling unit with thermal break profile and internal coving, double skin panels minimum 43±2 mm thick fabricated out pre-plasticized 22 swg GSS on outer side and plain 22 swg Galvanized sheet on inner side with PUF insulation density not less than 40 kg/m3 sandwiched between inner and outer sheet. , EU-4 filter section with filters, Coil Section with min. 6/8 Row DX coil, Metallic Moisture Eliminator Removable , Sliding Type Arrangement with access door, and SS drain pan, Supply air Blower section with DIDW centrifugal imported fan driven by High Energy Efficient (EFF1) motor and assembly. EU-7 filter section with filters. AHU Dampers to be of Extruded Aluminum Low Leakage Aerofoil Volume Control Dampers with extanded shaft suitable for Manual & Motorised operation & Necessary cabling & earthing strip. Limit switches for AHU doors, inspection lamps with fire proof Double Canvass connection (Fungal and Lint free). Junction box with contactor strip to be provided on the outer panel with positive isolation for electrical shock for heater connection.Fan static pressure shall be minimum 50/65 mm or higher if required to overcome actual pressure drop.Cooling coil to be selected as per minimum 500 FPM and 6 Row or as required to achieve required coil leaving conditions. Limit Switch, Lamp, Fire Damper etc control wiring to be given at one location on AHU.For detailed constructional feature, please refer Technical Annexure.The vendor shall comply with EN 1886-2007 for Casing Air Leakage (L2), Filter Bypass Leakage, Mechanical strength, Thermal Transmittance & Thermal Bridging Specification to be read following sequence- GTH-AHU capacity & St. pressure in mm of water coloum.Minimum AHU Fan Efficiency - 75%
-
-
-
AHU - 34.00 TR / 11,000 CFM / 65mm St.Pr. / 10µ & 20µ Combinatin Filter / 3µ Filter
2
-
-
Supply installation testing and commissioning of HVAC dedicated VFD's with IP 55 enclosure meeting with the tender specifications and having built in EMC filters to meet class 1B / C1 (with minimum 50 meters of output cabling) for restrictions of conducted emissions, along with internal harmonic filters on the DC bus to reduce THVD to below 5% & having built in 3 PID controllers in order to control 3 additional HVAC devices.
-
-
-
For 7.46 KW AHU Motor
2
-
-
Supply / Installation / Testing / Commissioning of FACTORY / SITE FABRICATED rectangular sheet metal ducts, as per specifications detailed in tender, made of Class VIII GP sheet as per SMACNA Standard for medium pressure air flow with MS angle / TDF flanges, supports, anchor fasteners, food grade gaskets and RTV sealant in accordance with the approved shop drawings. it is mandotary to use factory fabricated ducts for minimum 85% of the ducting system. Use of Site fabricated ducts should be restricted to only 'to suit' pieces.Cold rolled sheets continuous galvanized sheet steel with zinc coating as per class VIII confirming to IS:277-1962 (revised)(where ever specified) of LFQ (Lock Forming Quality) grade. Galvanizing shall be of 120gms/sq. m (Total coating on both sides) The fabrication of the ducting system for air-conditioning & Ventilation shall confirm to SMACNA-1995 standards ("HVAC Duct Construction Standards - Metal and Flexible - Second Edition - 1995"-SMACNA).Ducts of following Guage/thickness with Flanges, G.I. Sheet Metal Duct (Rectangular OR Round)
-
-
-
0.63 MM (24G) - Rectangular Duct
440
-
-
0.80 MM (22G) - Rectangular Duct
1
-
-
1.00 MM (20G) - Rectangular Duct
1
-
-
1.20 MM (18G) - Rectangular Duct
32
-
-
0.63 MM (24G) - Round Duct
1
-
-
0.80 MM (22G) - Round Duct
1
-
-
1.00 MM (20G) - Round Duct
1
-
-
1.20 MM (18G) - Round Duct
1
-
-
Supply,installation,testing and commissionig of extruded aluminium powder coated linear/Curved Grilles for Supply /Return grill with volume control dampers.
14
-
-
Fire Dampers shall meet the fire resistance rating of 2 hours as per UL555 and shall be tested and certified by CBRI.Fire Damper frame shall be galvanized steel of 1.6mm thickness, formed into a C channel in 4-piece construction with flanges suitable for duct connection. Damper Blades shall be single skin galvanized steel of 1.6mm thickness and must have 3 accurately rollformed longitudinal grooves for reinforcement and proper closure and operation. The blades shall be arranged in parallel to provide positive shut off. Each Blade shall have axles supported on both sides with sintered bronze self lubricating bearings turning in an extruded hole in the frame. All Blades shall be interconnected using linkage in the frame section . Each Damper shall be operated through a actuator. Each Damper shall be supplied with a factory mounted sleeve made from Minimum 1mm thick galvanized steel of minimum 250mm length
4
-
-
Supply / Installation / Testing / commissioning Of Actuator With It's Cabling.
8
-
-
Supply / Installation / Testing / commissioning Of Fresh Air GI Duct Dampers with bird screen & Cowl Piece
1
-
-
Supply / Installation / Testing / commissioning Of GI Duct Dampers.
3
-
-
Supply / Installation / Testing / commissioning Of Acoustic Insulation Of Ducts with Nitrile Rubber. The density of the same shall be within 140 to 180 Kg/m3 (thickness to be confirmed by Insulation Supplier)
a) 15 MM THK
110
-
-
Supply / Installation / Testing / commissioning Of Thermal Insulation Of Supply Ducts with Nitrile Rubber ( Exposed To Atmosphere Duct Will Be Cover With Glass Cloth & UV Paint ). Density of Material shall be between 40 to 60 Kg/m3 (thickness to be confirmed by Insulation Supplier)
a) 19 MM THK
376
-
-
Supply / Installation / Testing / commissioning Of AHU Room Wall Acoustic Insulation with 20mm THK Nitrile Rubber. The Density Of The Material Shall Be Between 140-180 Kg/m3
140
-
-
Supply / Installation / Testing / commissioning Of Under deck Insulation with 25mm THK Nitrile Rubber. Density Of Material Shall Be Between 40 to 60 Kg/m3
650
-
-
Ventilation Work:- Supply / Installation / Testing / Commissioning Wall Mounted Free Flow Propeller Fans For Toilet / Pantry.
-
-
-
800 CFM
1
-
-
300 CFM
7
-
-
150 CFM
25
-
-
Supply / Installation / Testing / Commissioning Ceiling Supspended Circular Fans For Toilet
-
-
-
300 CFM
5
-
-
AIR-COOLED HI-WALL UNITS :
Supplying and erecting split type room Airconditioning unit 2.00 TR 5 star capacity 250V, 50 cycles, A.C. supply having 1 No of air handling unit hiwall / floor mounting type complete with Refrigerent R410 A/R32 and COPPER CONDENSOR at position as per specification no. AP-AC/SAC
-
-
-
2.00 TR - 5 Star Rating
2
-
-
Supply, Installation, Testing & Commissioning of PVC Drain piping for the unit with 6mm thick nitrile rubber insulation
-
-
-
25 MM Dia
15
-
-
Supplying and erecting Iron, sheet metal work consisting of CRCA Sheets, Various sections of iron, Plates, Chequered Plates, Rods, Bars, MS pipes, etc. for panel board or any other purposes complete with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the Authority
100
-
-
Sequential controller for equal run time operation. The same should be able to run 1 units at a time out of 2 units. Controller will be time and temperature based.
1
-
-
Supply / Installation / Testing / Commissioning Of Cable Tray:- Providing & erecting Hot dipped Galvanised Perforated type Cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 300 mm width & 75 mm height complete with necessary coupler plates & ardware in approved manner.
300 mm x 75mm
50
-
-