Pune University Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Pune University - UOFP Tender

Works
Civil And Construction
Civil Works Others
Eprocure
Opening Date10 Jan 2024
Closing DateCancelled
Tender Amount₹ 3,30,07,376 
Notes
Download

Costs

Summary

Construction Of Vertical Extension To The Pavilion Building At Savitribai Phule Pune University Pune

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Get the Best Price For TMT
Starting from
₹57,500/MT*
Maharashtra

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete. Spec. No.:- Bd.A.11 Page One Number 263

10

12802

1280.25

... More
Removing brick bat coba including stacking the spoils as directed with all leads, lifts etc, complete. Rate for First Floor Spec. No.:- As directed by Engineer incharge.

99.1

66429

670.33

... More
Disposal of excavated material upto lead of 3 km including carting away upto municipal dumping ground loading, unloading, spreading etc. complete. As directed by Engineer in charge

118.9

26158

220

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite/quartzite/gneiss metal for foundation and bedding / steps including steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.),with fully automatic micro processor based PLC without SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Spec. No.:- Bd.E.2 Page One Number 288 andB.7 Page No 38

2

14597

7298.65

... More
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering, formwork ,cover blocks, laying/pumping, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC without SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Spec. No.:- Bd.F.3 Page One Number 298 and B.7, Page One Number38

2

16481

8240.95

... More
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC without SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) RATE FOR SECOND FLOOR Spec. No.:- Bd.F.5 Page One Number 300 andB-7,Page No 38.

76.4

1186125

15525.2

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC without SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) RATE FOR SECOND FLOOR Spec. No.:- Bd.F.6 Page One Number 300 and B.7, Page One Number38

58.3

810699

13905.65

... More
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC without SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) RATE FOR SECOND FLOOR Spec. No.:- Bd.F.8 Page One Number 302 and B.7, Page One Number38

37.5

588166

15684.45

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC without SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) RATE FOR SECOND FLOOR Spec. No.:- Bd.F.11 Page One Number 304 and B.7, Page One Number 38

9.85

171697

17431.2

... More
Providing and laying Cast in situ/Ready Mixcement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC without SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) RATE FOR SECOND FLOOR Spec. No.:- Bd.F.9 Page One Number 303 and B.7, Page One Number38

2.7

42348

15684.45

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap / quartzite/granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC without SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) RATE FOR SECOND FLOOR Spec. No.:- Bd. F. 13 Page One Number 305/I.S. 456 (2000

5.85

80047

13683.35

... More
Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. RATE FOR SECOND FLOOR Spec. No.:- Bd.F.17, Page One Number 306

26.2

2512383

95892.5

... More
Providing and fabricating structural steel work in rolled sections, fixed with connecting plates or angle cleats in main and cross beams, hip and jack rafters, purlins connecting to truss members and the like, as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted/ bolted/ welded connections and one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete. RATE FOR SECOND FLOOR Spec. No.:- Bd.C.3 Page One Number 275

35.39

3698619

104504.4

... More
Providing, fabricating and erecting at site of work the tubular steel structure (shed) as per standard design and specifications having various spans in between trusses and in multiples of standard length of bays as specified as per standard specifications, inclusive of cost of steel tubular trusses, tubular columns purlins, tie runners, foundation bolts, base plates, nuts and bolts, welding wherever required etc. as per detailed drawing inclusive of one coat of anticorrosive paint and two coats of oil painting of approved quality and shade etc. complete. Spec. One Number : As directed by Engineer-in-charge. RATE FOR SECOND FLOOR Spec. No.:- B-18 Page One Number 78

0.5

61377

122754.3

... More
Supply and Installation of concealed fix/stading seam non screwing type self supported reverse T clip type free flowing Concealed fix roofing system with nominal 430 mm effective cover width & two major corrugations of nominal 65 mm depth. The flat portion of the panel shall have three longitudinal flutes parallel to major corrugations at pitch of nominal 107.5 mm center to center spacing for strength.(Considered to be factory/ site roll formed.)The profile should have 3micro ribs mini ribs to provide additional strength at the pan, and material test certificate (MTC) to be submitted for each lot supplied at site. NOTE: The galvanised iron colour coated base coils for production of roofing sheets will be of nominal 0.5 mm Total Coated Thickness (TCT), Hi-strength steel with min. 300 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% Aluminium, 45% Zinc) as per ASTMA_755_2003G_80_550 Class1 & IS 15961 (2012) Galvalume AZ150 (Min. 150 gms/sq.mt total on both sides) with Regular modified quality paint coat . The paint shall have a total coating thickness of nominal 25 μm, comprising of nominal 18-20 μm exterior coat on top surface and nominal 5-6 μm reverse coat on back surface over nominal 5 μm primer coat on both surfaces of approved colour shade by concern authority. The steel manufacturer's test certificate for the chemical and mechanical properties of steel must be submitted for approval by the concerned authority prior to installation. The sheet shall have brand marking of the manufacturer giving product details on the back of the sheet at every 1 meter c/c for confirming genuinity of the material.System should accompany with The support aluminium clip shall be manufactured from extruded aluminium alloy 6061 T6 in accordance with BSEN 485 part 2. Each aluminium clip shall be coupled with a 5mm thick black polyamide thermal barrier base pad. and fixed on Aluminum clip and which is fixed to steel with SS-304 screwsand standard accessories like Foam Fillers, Drip Angles to ensure weather tightness.Complete installation to be done by specialized authorised team/installer of the manufacturer with safety & Site engineer. INSULATION LAYER:The insulation shall be 125 mm thick (laid in two layers of 75 & 50 mm fiberglass with minimum density 24 kg/m3 or Rockwool with minimum density 64 kg/m3 to achieve minimum U value of 0.26 W/m2 K,and minimum R- Value of insulation -3.70 sqm-k/w as approved by Engineer-In-Charge. SUPPORT SUB STRUCTURE: Galvanised steel Top hats with saddles of min. thickness of 1.6mm and to be installed over the VCL, liner sheet, with min. yield strength of 240 Mpa and with min 80GSM Galvanizing coat to be fixed with Steel fasteners. BOTTOM LAYER: Supply of colour coated sheet of nom.1015 mm effective cover width and nominal 28.5 mm deep ribs with subtle square fluting in the five pan at nominal 202 mm centre-to-centre. The end rib shall be designed for anticapillary action, to avoid any seepage of water through the lateral overlap. The feed material is manufactured out of nominal 0.5 mm Total Coated Thickness (TCT), Hi-strength steel with min. 550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% Aluminium, 45% Zinc) as perASTMA_755_2003G_80_550 Class1 & IS 15961 (2012) (Min. 150 gms/sq.mt total on both sides) with Regular modified quality paint coat . The paint shall have a total coating thickness of nominal 25 μm, comprising of nominal 18-20 μm exterior coat on top surface and nominal 5-6 μm reverse coat on back surface over nominal 5 μm primer coat on both surfaces of approved colour shade by concern authority. The steel manufacturer's test certificate for the chemical and mechanical properties of steel must be submitted for approval by the concerned authority prior to installation. The sheet shall have brand marking of the manufacturer giving product details on the back of the sheet at every 1 meter c/c for confirming genuinity of the material. Spec. No.:- As directed by Engineer in charge. (RATE FOR SECOND FLOOR)

1165.71

4868646

4176.55

... More
Supply & Installation of Flashings and trims:- Supply & Fixing of All the accessories like flashing / capping shall be made from the same material which is used for main roofing (upto 620mm girth) as per the dwg. Spec. No.:- As directed by Engineer in charge. (RATE FOR SECOND FLOOR)

1304.1

769810

590.3

... More
Providing and fixing valley gutter of 22 B.W.G. (0.8 mm) plain galvanised iron sheets 90 cm wide with teak wood planking 20 mm thick including two coats of coal-tarring the upper surface of plank etc. complete. (excluding painting to underside of plank). RATE FOR SECOND FLOOR Spec. No.:- Bd. R. 10, Page One Number 455

156

369883

2371.05

... More
Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete RATE FOR SECOND FLOOR Spec. No.:- Bd.G.5 Page One Number 315

260.19

2494753

9588.2

... More
Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of 2 bars of 6 mm diameter / 2 hoop iron strips 25 mm X 1.6 mm placed at every third course, properly bent and bonded at ends scaffolding, racking out joints and watering etc. complete. RATE FOR SECOND FLOOR Spec. No.:- Bd.G.7 Page One Number 316

46.5

61326

1318.85

... More
Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1Kilogramper bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete. RATE FOR SECOND FLOOR Spec. No.:- As directed by Engineer in charge.

194.8

269836

1385.2

... More
Providing waterproofing in W.C. and bath including brick bat coba in all position including providing and laying 12mm bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound @ 1Kilogram/per bag of cement laying brick bat coba of required thickness in cm 1:5 with waterproofing compound 1 Kilogram/bag of cement grouting and finishing the top layer with 20mm thick brick bedding in cm mortor 1:3 with waterproofing compound 1 Kilogram/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etc. complete. RATE FOR SECOND FLOOR Spec. No.:- As directed by Engineer in charge

11.1

85277

7682.7

... More
Providing water proof bedding for flooring of Bath and WC 25 mm thick in C.M. 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete. RATE FOR SECOND FLOOR Spec. No.:- As directed by Engineer in charge.

4.8

2377

495.3

... More
Providing and applying water proofing treatment using acrylic polymer modified cement based water proofing coating with fibre glass mesh mixing at the rate of powder to liquid (2:1) by weight covering 9 to 10 Square Metre /Kilogram with two coat using approved chemicals for masonry and concrete surface by brush covering 7 years guarantee on Stamp Papers etc. complete. RATE FOR SECOND FLOOR Spec. No.:- As directed by Engineer in charge

2

1314

657.45

... More
Providing internal cement plaster 12mm thick in single coat in cement mortar 1:3 without neeru finish to concrete or brick surfaces, in all position including scaffolding and curing etc. complete. RATE FOR SECOND FLOOR Spec. No.:- Bd.L.2 Page One Number 368

1843.5

604760

328.05

... More
Providing internal cement plaster 6 mm thick in a single coat in cement mortar 1:3 without neeru finish to concrete surface in all positions including scaffolding and curing etc. complete. RATE FOR SECOND FLOOR Spec. No.:- Bd.L.1 Page One Number 367

171.5

39976

233.1

... More
Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete. RATE FOR SECOND FLOOR Spec. No.:-As directed by Engineer incharge.

171.49

16497

96.2

... More
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. RATE FOR SECOND FLOOR Spec. No.:- Bd.L.7 Page One Number 369

1043.5

756694

725.15

... More
Providing and applying gypsum plaster ( with Gypsum material ) with finishing with gypsum material in 10 to 13 millimeter thickness to previously plastered surface / or on newly brick surface ( Excluding rough cast plaster ) in all position including preparing and Finishing the surface scaffolding etc.complete. RATE FOR SECOND FLOOR Spec. No.:- As directed by Engineer in charge.

1843.5

1507614

817.8

... More
Providing and Fixing of Mineral Fibre Board Acoustical Suspended Ceiling System with ultima (Bevelled Tegular) Edge Tiles of size 15mm Exposed GRID. The tiles should have Humidity Resistance (RH) of 99%, NRC 0.7, Light Reflectance 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 20mm , suitable for Green Building application, with Recycled content of 32%. The tile shall be laid on precoated G.I.channel on XL2 Clip having a web height of 32 mm with 15 mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm and 600 mm Cross Tees with a web height of 32 mm and a load carrying capacity of 7.7 Kilograms/M2 and minimum pull out strength of 100 Kilograms.. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system. The Tile and Grid system used together should carry a 10 year warranty. products approved as per GRIHA and BS 476 etc. complete. RATE FOR GROUND FLOOR Spec. No.:- As directed by Engineer in charge.

6

15048

2508.15

... More
Providing and fixing in position Gypsum board false ceiling with 12.5 mm thick Gypsum boards, screwed/fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete. Spec. No.:- As directed by Engineer in charge.

-

-

-

... More
Ground Floor

6

11134

1855.7

... More
First Floor

6

11240

1873.4

... More
Second Floor

414.93

784664

1891.1

... More
Providing and fixing in position Gypsum board false ceiling with 12.5 mm thick Gypsum boards, screwed/fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete. Spec. No.:- As directed by Engineer in charge.

-

-

-

... More
Ground Floor

3.45

7400

2145.2

... More
First Floor

3.63

7861

2165.65

... More
Second Floor

99.75

218061

2186.1

... More
Providing and fixing in position Gypsum board false ceiling with 12.5 mm thick Gypsum boards, screwed/fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete. Spec. No.:- As directed by Engineer in charge.

-

-

-

... More
First Floor

3.96

55066

13905.7

... More
Second Floor

44.03

618049

14037

... More
Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete. RATE FOR SECOND FLOOR Spec. No.:- Bd.M. 12 Page One Number385

85.1

108038

1269.55

... More
Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete RATE FOR SECOND FLOOR Spec. No.:- Bd.M. 12 Page One Number385

7.6

10258

1349.75

... More
Providing and laying vitrified matt fininsh tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete. RATE FOR SECOND FLOOR Spec. No.:- Bd.M.12 Page One Number 385

39.7

68353

1721.75

... More
Providing and laying vitrified matt finish tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. RATE FOR SECOND FLOOR Spec. No.:- Bd.M.12 Page One Number 385

158.97

286448

1801.9

... More
Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete. RATE FOR SECOND FLOOR Spec. No.:- Bd. M.22B/Page One Number 390

46.7

208805

4471.2

... More
Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete. RATE FOR SECOND FLOOR Spec. No.:- Bd.M. 3 B/PageOne Number 380

173

746149

4313

... More
Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etc. complete. RATE FOR SECOND FLOOR Spec. No.:- As directed by Engineer-In- Charge

162

761391

4699.95

... More
Providing and fixing machine cut mirror polished 18 mm to 20 mm thick telephone black granite / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone partition with full moulding the edges etc. complete . Both side polish RATE FOR SECOND FLOOR Spec. No.:- Bd.M.35 B/Page One Number393

7.2

30953

4299.15

... More
Providing and laying machine cut machine Polished Kota stone flooring 25mm to 30mm thick and required width in plain/ diamond pattern on bed of 1:6 C. M. including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete. RATE FOR SECOND FLOOR Spec. No.:- Bd.M.3 Page One Number 380

550

739420

1344.4

... More
Providing and fixing in required position skirting or dado of polished Kotah Stone slab 25 mm to 30 mm thick fixed on base on plaster of cement mortar 1:4 including cement float, filling joints with cement slurry, curing rubbing, polishing and cleaning complete. RATE FOR SECOND FLOOR Spec. No.:- As directed by Engineer in Charge

21.6

31278

1448.1

... More
Providing and laying Rubberized Gym Flooring Technical Specification: Providing and laying Rubberized Gym Flooring of 20mm thick Safe lock Interlocking rubber tiles of sizes (50 X50 cm or 48 X 48 cm) with 4.6 kgs weight for gymnasium floor. Safelock is a mix of natural rubber & recycled rubber with Elephant skin pattern. It will be UV resistant & the thicker layer of rubber matting protects the floor as well as the user. It also dampens sound & absorbs shocks. including cost of all required materials for fixing, labour, conveyance, sundries, T&P, complete as per direction of Engineer-in-Charge. RATE FOR ALL FLOOR

550

1623297

2951.45

... More
Providing and applying pearl/ luster finish paint of approved colour and shade to the existing plaster surface including scaffolding, preparing the surface, applying the acrylic wall putti etc.complete. RATE FOR SECOND FLOOR Spec. No.:- As directed by Engineer incharge.

2015

465263

230.9

... More
Providing and applying two coats of exterior acraylic emulsion paint confirming to corresponding I.S. of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface, applying primer coat ,scaffolding if necessary , and watering the surface for two days etc complete. RATE FOR SECOND FLOOR Spec. No.:- As directed by Engineer in charge.

1043.5

291136

279

... More
Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete. RATE FOR SECOND FLOOR Spec. No.:- As directed by Engineer in charge.

0.9

192468

213853.45

... More
Providing and fixing flush door shutter in Single leaf 34 mm thick with teak wood bidding of size 32x12mm thk finished with 1 mm thick laminate of approved colour on both faces also including vision panel glass 5mm thick fixing with teak wood bidding on both side of vision as per given detail drawing and all necessary hardware & accessories like Hinges, D type handles on both sides, Tower bolt, Aldrops, Door stopper, as directed by Engineer Incharge etc.complete. RATE FOR SECOND FLOOR (SPPU NRB RA)

24

147128

6130.35

... More
Providing and fixing flush door shutter in Double leaf 34 mm thick with teak wood bidding of size 32x12mm thk finished with 1 mm thick laminate of approved colour on both faces also including vision panel glass 5mm thick fixing with teak wood bidding on both side of vision as per given detail drawing and all necessary hardware & accessories like Hinges, D type handles on both sides, Tower bolt, Aldrops, Door stopper, as directed by Engineer Incharge etc.complete. RATE FOR SECOND FLOOR (SPPU NRB RA)

18

114862

6381.25

... More
Providing and fixing fiber glass reinforced polyster door shutter 30mm thick as per IS 14856 (2000) (Reaffirmed 2006)without ventilator including chromium plated fixtures and fastening with chromium plated handles on both sides, etc complete Spec. No.:- As directed by Engineer in charge.

15.2

53199

3499.95

... More
Providing and fixing in position (as per 1868 / 1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 Kilogram/One Running Metre. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 Kilogram/One Running Metre.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 Kilogram/Running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/One Running Metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/Running metre. and handle and top section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With powder coating without box. RATE FOR SECOND FLOOR Spec. No.:- As directed by Engineer in charge.

64.8

344139

5310.8

... More
Providing & fixing of structural glazing system with approved powder coating 60 to 80 mic, Jindal make aluminium profiles , mullion of size 130 x 70mm & transom of size 130 x 70mm fixed on slab / beam with ms HDG bracket, anchor fastner Hilti make, SS nut bolt , standard stainless screws , required aluminium cleats , angle , sleeve, toggle and using 24mm thick DGU , 6mm thick ST 120 HS from out side + 12mm air gap + 6mm clear toughen glass from inside glazed on secondary frame with double side spacer tape, structural silicone DC make & glass to glass joint filled with weather silicone etc. complete including Outer & Inner Toughen or Clear glass & Specific Colour as approved by architect or engineer incharge. NON DSR ITEM. RATE FOR ALL FLOOR

222.5

1883308

8464.5

... More
Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 mm x 1.22 mm box type, 5 mm thick sheet glass louvers, of approved quality etc. complete. RATE FOR SECOND FLOOR Spec. No.:- As directed by Engineer in charge.

2.2

8153

3706.25

... More
Providing and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/ One Square Metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. RATE FOR SECOND FLOOR Spec. No.:- Bd.U.1 Page One Number 537

70.35

157703

2241.7

... More
Providing and Fixing mat finish stainless steel (of 302 grade ) railing with top pipe of 50 mm dia. and vertical pipe of 38 mm dia at 0.60 m c/c or as required and horizontal pipes of 25 mm dia in three rows, all pipes of 2 mm thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 mm dia above newel post of 75 mm diameter etc. complete (Prior approval of sample and brand by Ex.Engineer is necessary before use) RATE FOR SECOND FLOOR Spec. No.:- As directed by Engineer Incharge.

9

34106

3789.6

... More
Providing and fixing on walls/ ceiling/ floors, 15 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes weight of 1.48 Kilogram/metre with necessary fittings. remaking good the demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in store or as directed etc. complete. RATE FOR SECOND FLOOR Spec. No.:- Bd.V.5 Page One Number 551

80

38828

485.35

... More
Providing and fixing on walls/ ceiling/ floors 20 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes of 1.93 Kilogram/meter with necessary fitting remaking good the demolished portion and applying primer of anti-corrosive oil paint, 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in store or as directed etc. complete. RATE FOR SECOND FLOOR Spec. No.:- Bd.V.5 Page One Number 551c

60

31620

527

... More
Providing and fixing on walls/ ceiling/ floors, 25 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes weight of 3.01 Kilogram/meter with necessary fittings . remaking good the demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in store or as directed etc. complete. RATE FOR SECOND FLOOR Spec. No.:- Bd.V.5 Page One Number 551

30

20493

683.1

... More
Providing and fixing on walls/ ceiling/ floors, 32 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes weight of 3.89 Kilogram/meter with necessary fittings . remaking good the demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in store or as directed etc. complete. RATE FOR SECOND FLOOR Spec. No.:- Bd.V.5 Page One Number 551

34

25296

744

... More
Providing and fixing on walls/ ceiling/ floors, 40 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes weight of 4.49 Kilogram/meter with necessary fittings and remaking good the demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in store or as directed etc. complete. RATE FOR SECOND FLOOR Spec. No.:- Bd.V.5 Page One Number 551

20

16442

822.1

... More
Providing and fixing on walls/ ceiling/ floors, 50 mm dia heavy grade having embossed as ISI Mark galvanised iron pipes weight of 6.33 Kilogram/meter with necessary fittings.and remaking good the demolished portion and primer of anti corrossive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in store or as directed etc. complete. RATE FOR SECOND FLOOR Spec. No.:- Bd.V.5Page One Number 551

20

21038

1051.9

... More
Providing and fixing 15 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete. RATE FOR SECOND FLOOR Spec. No.:- Bd.V.8 Page One Number 554

2

1434

717.3

... More
Providing and fixing screw down 15 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete. RATE FOR SECOND FLOOR Spec. No.:- Bd.V.9 Page One Number 555

2

1103

551.6

... More
Providing and fixing screw down for 20 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete. RATE FOR SECOND FLOOR Spec. No.:- Bd.V.9 Page One Number 555

2

1368

684.15

... More
Providing and fixing screw down for 40 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete. RATE FOR SECOND FLOOR Spec. No.:- Bd.V.9 Page One Number 555

4

5007

1251.8

... More
Providing and fixing screw down for 50 mm dia. wheeled stop tap of brass including necessary sockets/ union nut complete. RATE FOR SECOND FLOOR Spec. No.:- Bd.V.9 Page One Number 555

4

8522

2130.5

... More
Providing and fixing White Glazed Earthenware full stall type Urinal with P.V.C. flushing cistern of 5 liters capacity with fitting, inlet pipes and stop tap, brackets for fixing the cistern, 32 mm dia. P.V.C flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap, soil pipe connectionup to the outside face of the wall. RATE FOR SECOND FLOOR Spec. No.:- Bd.V.23 Page One Number 562

6

62766

10461.15

... More
Providing and laying 100 mm dia. half round white glazed earthenware pipes in 1:5:10 cement concrete bedding including bends, etc. complete. RATE FOR SECOND FLOOR Spec. No.:- Bd.V.29 Page One Number 565

24

11468

477.85

... More
Providing and fixing White glazed with bottle trap earthenware Wash Hand Basin of 55x40 cm size including cold water piller taps, brackets, rubber plugs and brass chain, stop tap, chromium plate bottle trap and necessary pipe connections including UPAC waste pipe and trap upto the outside face of the wall, making good the damaged surface, testing etc. complete. RATE FOR SECOND FLOOR Spec. No.:- BDV.-30 PageOne Number616

8

55458

6932.35

... More
Providing and fixing 10 cm PVC nahani trap with grating etc. complete. RATE FOR SECOND FLOOR Spec. No.:- BD.V 32 A page 551 and as directed by Engineer incharge

14

8245

588.95

... More
Providing and fixing stainless steel sink of size 600 x 510 x 200 mm incluidng coupling, outlet pipe, elbow and other necessary fitting, finishing etc. complete. RATE FOR SECOND FLOOR Spec. No.:- As directed by Engineer incharge

1

21273

21273.1

... More
Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap Spec. No.:- Bd.V.38, Page One Number 572

2

4014

2007.1

... More
Providing and laying concrete pipes of I.S.NP. class of 150mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. Spec. No.:- Bd.V.41, Page One Number 573

10

5559

555.95

... More
Providing and laying concrete pipes of I.S.NP. class of 225mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. Spec. No.:- Bd.V.41, Page One Number 573

10

5885

588.5

... More
Providing and laying concrete pipes of I.S.NP. class of 300mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. Spec. No.:- Bd.V.41, Page One Number 573

5

3902

780.45

... More
Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140Kilogramwith frame etc complete. Spec. No.:- Bd.V.43, Page One Number 574

2

24955

12477.95

... More
Providing and constructing Brick Masonry inspection trap Chamber 90cm x 45cm including 1:4:8 C.C foundation, 1:2:4 C.C.channels/half round glazed stoneware pipe channel, salt glazed stone-ware intercepting trap with rodding pipe set in 1:4:8 cement concrete block, brick masonry plastering inside and Outside, fixed in cement concrete with R.C.C. Cover medium duty 140 Kilogram. etc complete Spec. No.:- Bd.V.44, Page One Number 575

2

29070

14535.35

... More
Providing and fixing 6 mm thk mirror on bracket/ stud with edge polishing/Bevelling to all sides with fittings etc complete . RATE FOR SECOND FLOOR (SPPU NRB RA) Spec. No.:- As directed by Engineer incharge.

8

37124

4640.5

... More
Providing and fixing 40 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirements etc. complete. RATE FOR SECOND FLOOR Spec. No.:- As directed by Engineer incharge.

4

5174

1293.5

... More
Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. RATE FOR SECOND FLOOR Spec. No.:- As directed by Engineer incharge.

30

19467

648.9

... More
Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. RATE FOR SECOND FLOOR Spec. No.:- As directed by Engineer incharge.

30

25270

842.35

... More
Providing and fixing H.D.P container one piece moulded water tank made out of low density polythyler and built corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity above 1000 to 20,000 litres. RATE FOR SECOND FLOOR Spec. No.:- As directed by engineer-in- charge.

4000

47000

11.75

... More
Providing and fixing C.P.Two way BIB cock of approved make continental including necessary sockets/union nut etc. complete. RATE FOR SECOND FLOOR Spec. No.:- As directed by Engineer incharge

4

6238

1559.7

... More
Providing and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete. RATE FOR SECOND FLOOR Spec. No.:- As directed by Engineer incharge

4

4737

1184.45

... More
Providing and fixing European type wall-hung white water closet of approved make with push valve concealed type with cover plate 32mm size of approved make including soil pipe, vent pipe up to outside face of wall ,100mm dia. G.I. plug bend inlet pipe all fittings, cuttingand making good walls, floors etc. complete. RATE FOR SECOND FLOOR Spec. No.:- As directed by Engineer Incharge

4

64429

16107.35

... More
Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and One Number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. RATE FOR SECOND FLOOR Spec. No.:- As directed by Engineer Incharge

20

12166

608.3

... More
Providing and fixing Hand shower (health faucet) with 8mm dia. 1m long flexible tube having wall hook with approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge. RATE FOR SECOND FLOOR Spec. No.:- As directed by Engineer in charge.

4

7949

1987.3

... More
Providing and fixing C.P. wall mixer with provision for overhead shower with 115mm long bend pipe and wall flange of approved make including necessary sockets/union nut etc.complete. RATE FOR SECOND FLOOR Spec. No.:- As directed by Engineer incharge

2

10129

5064.9

... More
Providing and fixing 100 mm dia. chromium plated brass showers rose to 15mm dia. supply pipe including necessary bend and socket complete. RATE FOR SECOND FLOOR Spec. No.:- Bd.V. 12 PageOne Number 556

2

1128

564.4

... More
Providing and fixing chromium plated towel rod 16 mm dia and 75 cm. in length including all accessories complete. RATE FOR SECOND FLOOR Spec. No.:- As directed by Engineer in charge.

2

639

319.65

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron)

2334.3

1117312

478.65

... More
Providing Plumber with tools - Skilled Spec. No: - As directed by Engineer in charge

5

3554

710.85

... More
Mazdoor, Unskilled Heavy Male/Female Spec. No: - As directed by Engineer in charge

10

6457

645.75

... More
Basic Test of Cement:- Standard Consistancy, Fineness, Specific Gravity, Setting Time ( Initial & Final ), Compressive Strength, Soundness

1

3770

3770

... More
BASIC TEST OF AGGREGATE:-

-

-

-

... More
Water Absorption, Specific Gravity,lmpact Value /Crushing Value.

1

2600

2600

... More
Sieve Analysis

1

690

690

... More
Abrasion Value

1

1170

1170

... More
Flakiness Index & Elongation Index

1

850

850

... More
Soundness

1

2495

2495

... More
FINE AGGREGATE/ SAND Test:- Fineness Modulus ( Sieve Analysis ), Silt & Clay Content

1

1380

1380

... More
BRICKS TEST:- Water Absorption (Set of 5 Bricks), Compressive Strength ( Set of 5 Bricks), Efflorescence (Set of 5 Bricks).

2

4350

2175

... More
CONCRETE CUBE TEST:- Compressive Strength OF C.C. Cube (Set of 3 cubes)

14

9660

690

... More
Concrete Mix Design:- (M25) (With all Tests on basic materials)

1

13755

13755

... More
MORTOR:- Compressive Strength.( Set of 3 Cubes) for(1:3 & 1:4 grade)

2

1380

690

... More
STEEL BAR TESTING Upto 16 mm (Set of 3 Bars):- (Tensile strength, %, Elongation, Yield Stress, Weight-Per Meter, Bend / Rebend Test, Proof Stress.)

4

5100

1275

... More
STEEL BAR TESTING Above 16 mm (Set of 3 Bars):- (Tensile strength, %, Elongation, Yield Stress, Weight-Per Meter, Bend / Rebend Test, Proof Stress.)

3

4785

1595

... More
FLUSH DOOR TEST:- Knife Test, Adhesion Test, End Immersion Test

1

2710

2710



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.