Public Works Department Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Public Works Department - PWD Tender

Works
Building Construction
Eprocure
Opening Date15 Oct 2024
Closing Date29 Oct 2024
Tender Amount₹ 75,88,35,161 
Notes
Download

Costs

  • EMD

    ₹ 38,00,000
  • Document Cost

    ₹ 3,540
  • Tender Fee

    ₹ 500

Summary

Upgradation Of 30 Bedded Rural Hospital To 100 Bedded Sub District Hospital And Construction Of Residential Quarters For Medical Superintendent,

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth /murum, ramming, watering including shoring and strutting, dewatering etc. complete (lift upto 1.5 metre) by Mechanical Means.

3751.31

-

-

... More
Excavation for foundation in Hard rock by chiselling, wedging, line drilling, etc. including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the building area stacking as directed, dewatering and back filling with available earth/ murum watering, ramming etc. complete. (Lift 1.5 To 3 metre) by Mechanical Means.

2211.24

-

-

... More
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper.

10963.11

-

-

... More
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per square metre of surface area covering ten years guarantee on bond paper.

4147.36

-

-

... More
Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 centimetre to 20 centimetre thick including hand packing and compacting etc. complete.

544.65

-

-

... More
Filling in plinth and floors with approved excavated material in 15 centimetre to 20 centimetre layers including watering and compacting etc. complete. Spec. No. : Bd.A. 11/Page No. 262

590.62

-

-

... More
Filling in plinth and floors with contractors material/ brought from outside and approved by Engineer incharge in layers of 15 centimetre to 20 centimetre including watering and compaction etc. complete. Spec. No. : Bd.A. 11/Page No. 263

2578.24

-

-

... More
Providing and laying Cast in situ/ Ready Mix cement concrete in Mix- 10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisition enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand V.S.I. Grade).

925.14

-

-

... More
Providing and laying in situ/ Ready Mix cement concrete Mix-35 of trap/ granite/quartzite/ gneiss metal for Reinforced Cement Concrete work in foundations like raft, strip foundations, grillage and footings of Reinforced Cement Concrete columns and steel stanchions etc. including bailing out water, formwork, laying/ pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided, (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade).

2463.7

-

-

... More
Providing and laying cast in situ/ Ready Mix cement concrete Mix-35 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete columns as per detailed designs and drawing or as directed including centering, formwork, cover blocks, laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade). Ground Floor

255.72

-

-

... More
Providing and laying cast in situ/ Ready Mix cement concrete Mix-35 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete columns as per detailed designs and drawing or as directed including centering, formwork, cover blocks, laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade). First Floor

206.52

-

-

... More
Providing and laying cast in situ/ Ready Mix cement concrete Mix-35 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete columns as per detailed designs and drawing or as directed including centering, formwork, cover blocks, laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade). Second Floor

202.22

-

-

... More
Providing and laying cast in situ/ Ready Mix cement concrete Mix-35 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete columns as per detailed designs and drawing or as directed including centering, formwork, cover blocks, laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade). Third Floor

202.22

-

-

... More
Providing and laying cast in situ/ Ready Mix cement concrete Mix-35 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete columns as per detailed designs and drawing or as directed including centering, formwork, cover blocks, laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade). Fourth Floor

287.93

-

-

... More
Providing and laying Cast in situ/ Ready Mix cement concrete Mix-35 of trap/ granite/quartzite/ gneiss metal for Reinforced Cement Concrete Beams and Lintels as per detailed designs and drawings or as directed including centering, formwork, cover blocks, laying/ pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel), with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade). Ground Floor

608.19

-

-

... More
Providing and laying Cast in situ/ Ready Mix cement concrete Mix-35 of trap/ granite/quartzite/ gneiss metal for Reinforced Cement Concrete Beams and Lintels as per detailed designs and drawings or as directed including centering, formwork, cover blocks, laying/ pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel), with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade). First Floor

275.51

-

-

... More
Providing and laying Cast in situ/ Ready Mix cement concrete Mix-35 of trap/ granite/quartzite/ gneiss metal for Reinforced Cement Concrete Beams and Lintels as per detailed designs and drawings or as directed including centering, formwork, cover blocks, laying/ pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel), with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade). Second Floor

363.5

-

-

... More
Providing and laying Cast in situ/ Ready Mix cement concrete Mix-35 of trap/ granite/quartzite/ gneiss metal for Reinforced Cement Concrete Beams and Lintels as per detailed designs and drawings or as directed including centering, formwork, cover blocks, laying/ pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel), with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade). Third Floor

331.7

-

-

... More
Providing and laying Cast in situ/ Ready Mix cement concrete Mix-35 of trap/ granite/quartzite/ gneiss metal for Reinforced Cement Concrete Beams and Lintels as per detailed designs and drawings or as directed including centering, formwork, cover blocks, laying/ pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel), with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade). Fourth Floor

284.87

-

-

... More
Providing and laying Cast in situ/ Ready Mix cement concrete Mix-35 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Slabs and Landings as per detailed designs and drawings including centering, formwork, cover blocks, laying/ pumping, compactionfinishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). Ground Floor

593.66

-

-

... More
Providing and laying Cast in situ/ Ready Mix cement concrete Mix-35 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Slabs and Landings as per detailed designs and drawings including centering, formwork, cover blocks, laying/ pumping, compactionfinishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). First Floor

592.59

-

-

... More
Providing and laying Cast in situ/ Ready Mix cement concrete Mix-35 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Slabs and Landings as per detailed designs and drawings including centering, formwork, cover blocks, laying/ pumping, compactionfinishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). Second Floor

540.06

-

-

... More
Providing and laying Cast in situ/ Ready Mix cement concrete Mix-35 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Slabs and Landings as per detailed designs and drawings including centering, formwork, cover blocks, laying/ pumping, compactionfinishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). Third Floor

599.1

-

-

... More
Providing and laying Cast in situ/ Ready Mix cement concrete Mix-35 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Slabs and Landings as per detailed designs and drawings including centering, formwork, cover blocks, laying/ pumping, compactionfinishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). Fourth Floor

656.11

-

-

... More
Providing and laying Cast in situ/ Ready Mix cement concrete in Mix-35 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Pardi of required thickness including centering, formwork, cover blocks, laying/ pumping, compacting, curing, finishing and rougheningthem if special finish is to be provided and curing complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). Ground Floor

47.44

-

-

... More
Providing and laying Cast in situ/ Ready Mix cement concrete in Mix-35 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Pardi of required thickness including centering, formwork, cover blocks, laying/ pumping, compacting, curing, finishing and rougheningthem if special finish is to be provided and curing complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). First Floor

34.02

-

-

... More
Providing and laying Cast in situ/ Ready Mix cement concrete in Mix-35 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Pardi of required thickness including centering, formwork, cover blocks, laying/ pumping, compacting, curing, finishing and rougheningthem if special finish is to be provided and curing complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). Second Floor

34.02

-

-

... More
Providing and laying Cast in situ/ Ready Mix cement concrete in Mix-35 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Pardi of required thickness including centering, formwork, cover blocks, laying/ pumping, compacting, curing, finishing and rougheningthem if special finish is to be provided and curing complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). Third Floor

34.02

-

-

... More
Providing and laying Cast in situ/ Ready Mix cement concrete in Mix-35 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Pardi of required thickness including centering, formwork, cover blocks, laying/ pumping, compacting, curing, finishing and rougheningthem if special finish is to be provided and curing complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). Fourth Floor

106.06

-

-

... More
Providing and laying Cast in situ/ Ready Mix cement concrete Mix-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Chajja as per detailed design and drawings including centering, formwork, cover blocks compacting , curing , finishing and roughening the surface if special finish is to be provided and curing complete (Excluding reinforcement and structural steel), with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). Ground Floor

25.09

-

-

... More
Providing and laying Cast in situ/ Ready Mix cement concrete Mix-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Chajja as per detailed design and drawings including centering, formwork, cover blocks compacting , curing , finishing and roughening the surface if special finish is to be provided and curing complete (Excluding reinforcement and structural steel), with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). First Floor

24.71

-

-

... More
Providing and laying Cast in situ/ Ready Mix cement concrete Mix-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Chajja as per detailed design and drawings including centering, formwork, cover blocks compacting , curing , finishing and roughening the surface if special finish is to be provided and curing complete (Excluding reinforcement and structural steel), with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). Second Floor

23.35

-

-

... More
Providing and laying Cast in situ/ Ready Mix cement concrete Mix-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Chajja as per detailed design and drawings including centering, formwork, cover blocks compacting , curing , finishing and roughening the surface if special finish is to be provided and curing complete (Excluding reinforcement and structural steel), with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). Third Floor

23.43

-

-

... More
Providing and laying Cast in situ/ Ready Mix cement concrete Mix-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Chajja as per detailed design and drawings including centering, formwork, cover blocks compacting , curing , finishing and roughening the surface if special finish is to be provided and curing complete (Excluding reinforcement and structural steel), with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). Fourth Floor

24.1

-

-

... More
Providing and laying Cast in situ/ Ready Mix cement concrete Mix-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Chajja as per detailed design and drawings including centering, formwork, cover blocks compacting , curing , finishing and roughening the surface if special finish is to be provided and curing complete (Excluding reinforcement and structural steel), with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). Fifth Floor

19.74

-

-

... More
Providing and laying Cast in situ/ Ready Mix cement concrete in Mix-25 of trap / quartzite /granite /gneiss metal for Reinforced Cement Concrete Waist Slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/ pumping, compaction, finishing uneven and honeycombed surface with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete, with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin ). Ground Floor

44.49

-

-

... More
Providing and laying Cast in situ/ Ready Mix cement concrete in Mix-25 of trap / quartzite /granite /gneiss metal for Reinforced Cement Concrete Waist Slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/ pumping, compaction, finishing uneven and honeycombed surface with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete, with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin ). First Floor

44.49

-

-

... More
Providing and laying Cast in situ/ Ready Mix cement concrete in Mix-25 of trap / quartzite /granite /gneiss metal for Reinforced Cement Concrete Waist Slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/ pumping, compaction, finishing uneven and honeycombed surface with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete, with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin ). Second Floor

42.28

-

-

... More
Providing and laying Cast in situ/ Ready Mix cement concrete in Mix-25 of trap / quartzite /granite /gneiss metal for Reinforced Cement Concrete Waist Slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/ pumping, compaction, finishing uneven and honeycombed surface with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete, with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin ). Third Floor

42.28

-

-

... More
Providing and laying Cast in situ/ Ready Mix cement concrete in Mix-25 of trap / quartzite /granite /gneiss metal for Reinforced Cement Concrete Waist Slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/ pumping, compaction, finishing uneven and honeycombed surface with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete, with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin ). Fourth Floor

42.28

-

-

... More
Providing and laying Cast in situ/ Ready Mix cement concrete in Mix-25 of trap / quartzite /granite /gneiss metal for Reinforced Cement Concrete Waist Slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/ pumping, compaction, finishing uneven and honeycombed surface with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete, with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin ). Fifth Floor

11.58

-

-

... More
Providing and fixing in position Thermo Mechanically Treated (TMT) FE -500 bar reinforcement of various diameters for Reinforced Cement Concrete pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules, including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. Ground Floor

526.75

-

-

... More
Providing and fixing in position Thermo Mechanically Treated (TMT) FE -500 bar reinforcement of various diameters for Reinforced Cement Concrete pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules, including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. First Floor

164.99

-

-

... More
Providing and fixing in position Thermo Mechanically Treated (TMT) FE -500 bar reinforcement of various diameters for Reinforced Cement Concrete pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules, including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. Second Floor

167.76

-

-

... More
Providing and fixing in position Thermo Mechanically Treated (TMT) FE -500 bar reinforcement of various diameters for Reinforced Cement Concrete pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules, including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. Third Floor

168.51

-

-

... More
Providing and fixing in position Thermo Mechanically Treated (TMT) FE -500 bar reinforcement of various diameters for Reinforced Cement Concrete pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules, including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. Fourth Floor

188.78

-

-

... More
Providing and fixing in position Thermo Mechanically Treated (TMT) FE -500 bar reinforcement of various diameters for Reinforced Cement Concrete pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules, including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. Fifth Floor

35.71

-

-

... More
Providing and laying Cast in situ/ Ready Mix cement concrete in Mix-20 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including centering, formwork, cover blocks, laying/ pumping, compacting , curing , finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel), with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade).

56.73

-

-

... More
Providing fly ash brick masonary with conventional /Indian Standardtype fly ash bricks in cement mortar 1:6 in foundation and plinth including bailing out water manually, striking joints, racking out joints, watering and scaffolding complete.

107.71

-

-

... More
Providing fly ash brick masonary with conventional /Indian Standard type fly ash brick in cement mortar 1:6 for superstructure including striking joints, racking out joints, watering and scaffolding complete. Ground Floor

1132.41

-

-

... More
Providing fly ash brick masonary with conventional /Indian Standard type fly ash brick in cement mortar 1:6 for superstructure including striking joints, racking out joints, watering and scaffolding complete. First Floor

1042.37

-

-

... More
Providing fly ash brick masonary with conventional /Indian Standard type fly ash brick in cement mortar 1:6 for superstructure including striking joints, racking out joints, watering and scaffolding complete. Second Floor

1015.67

-

-

... More
Providing fly ash brick masonary with conventional /Indian Standard type fly ash brick in cement mortar 1:6 for superstructure including striking joints, racking out joints, watering and scaffolding complete. Third Floor

1081.64

-

-

... More
Providing fly ash brick masonary with conventional /Indian Standard type fly ash brick in cement mortar 1:6 for superstructure including striking joints, racking out joints, watering and scaffolding complete. Fourth Floor

1351.37

-

-

... More
Providing fly ash brick masonary with conventional /Indian Standard type fly ash brick in cement mortar 1:6 for superstructure including striking joints, racking out joints, watering and scaffolding complete. Fifth Floor

315.91

-

-

... More
Providing and fixing chicken mesh of 22 gauge, with about 30 centimetre width at the junction of Reinforce Cement Concrete members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete/ Burnt Brick Masonry and or tying by binding wire etc. complete. Ground Floor

2734.57

-

-

... More
Providing and fixing chicken mesh of 22 gauge, with about 30 centimetre width at the junction of Reinforce Cement Concrete members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete/ Burnt Brick Masonry and or tying by binding wire etc. complete. First Floor

4502.14

-

-

... More
Providing and fixing chicken mesh of 22 gauge, with about 30 centimetre width at the junction of Reinforce Cement Concrete members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete/ Burnt Brick Masonry and or tying by binding wire etc. complete. Second Floor

4352.84

-

-

... More
Providing and fixing chicken mesh of 22 gauge, with about 30 centimetre width at the junction of Reinforce Cement Concrete members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete/ Burnt Brick Masonry and or tying by binding wire etc. complete. Third Floor

4525.06

-

-

... More
Providing and fixing chicken mesh of 22 gauge, with about 30 centimetre width at the junction of Reinforce Cement Concrete members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete/ Burnt Brick Masonry and or tying by binding wire etc. complete. Fourth Floor

4656.1

-

-

... More
Providing and fixing chicken mesh of 22 gauge, with about 30 centimetre width at the junction of Reinforce Cement Concrete members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete/ Burnt Brick Masonry and or tying by binding wire etc. complete. Fifth Floor

1729.51

-

-

... More
Providing internal cement plaster 12 milimetre thick in single coat in cement mortar 1:3 without neeru finish to concrete or brick surfaces, in all position including scaffolding and curing etc. complete. Ground Floor

3686.24

-

-

... More
Providing internal cement plaster 12 milimetre thick in single coat in cement mortar 1:3 without neeru finish to concrete or brick surfaces, in all position including scaffolding and curing etc. complete. First Floor

3964.35

-

-

... More
Providing internal cement plaster 12 milimetre thick in single coat in cement mortar 1:3 without neeru finish to concrete or brick surfaces, in all position including scaffolding and curing etc. complete. Second Floor

3687.96

-

-

... More
Providing internal cement plaster 12 milimetre thick in single coat in cement mortar 1:3 without neeru finish to concrete or brick surfaces, in all position including scaffolding and curing etc. complete. Third Floor

3865.08

-

-

... More
Providing internal cement plaster 12 milimetre thick in single coat in cement mortar 1:3 without neeru finish to concrete or brick surfaces, in all position including scaffolding and curing etc. complete. Fourth Floor

4673.83

-

-

... More
Providing internal cement plaster 12 milimetre thick in single coat in cement mortar 1:3 without neeru finish to concrete or brick surfaces, in all position including scaffolding and curing etc. complete. Fifth Floor

1116.56

-

-

... More
Providing internal cement plaster 20 mm. thick in two coats in cement mortar 1:3 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete. Ground Floor

1595.13

-

-

... More
Providing internal cement plaster 20 mm. thick in two coats in cement mortar 1:3 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete. First Floor

2064.75

-

-

... More
Providing internal cement plaster 20 mm. thick in two coats in cement mortar 1:3 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete. Second Floor

1776.43

-

-

... More
Providing internal cement plaster 20 mm. thick in two coats in cement mortar 1:3 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete. Third Floor

2276.16

-

-

... More
Providing internal cement plaster 20 mm. thick in two coats in cement mortar 1:3 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete. Fourth Floor

2237.58

-

-

... More
Providing internal cement plaster 20 mm. thick in two coats in cement mortar 1:3 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete. Fifth Floor

482.67

-

-

... More
Providing and applying plaster with plaster of paris in 6 milimetre thickness to previously plastered surface in all position including preparing the surface scaffolding etc. complete. Ground Floor

2955.6

-

-

... More
Providing and applying plaster with plaster of paris in 6 milimetre thickness to previously plastered surface in all position including preparing the surface scaffolding etc. complete. First Floor

3767.94

-

-

... More
Providing and applying plaster with plaster of paris in 6 milimetre thickness to previously plastered surface in all position including preparing the surface scaffolding etc. complete. Second Floor

3503.89

-

-

... More
Providing and applying plaster with plaster of paris in 6 milimetre thickness to previously plastered surface in all position including preparing the surface scaffolding etc. complete. Third Floor

3743.2

-

-

... More
Providing and applying plaster with plaster of paris in 6 milimetre thickness to previously plastered surface in all position including preparing the surface scaffolding etc. complete. Fourth Floor

3552.26

-

-

... More
Providing and applying plaster with plaster of paris in 6 milimetre thickness to previously plastered surface in all position including preparing the surface scaffolding etc. complete. Fifth Floor

834.94

-

-

... More
Providing and applying gypsum plaster (with Gypsum material of Gypsum India/ Mega Sign or equivalent make) with finishing with gypsum material in 10 to 13 millimeter thickness to previously plastered surface/ or on newly brick surface (Excluding rough cast plaster) in all position including preparing and Finishing the surface scaffolding etc. complete. Ground Floor

5278.33

-

-

... More
Providing and applying gypsum plaster (with Gypsum material of Gypsum India/ Mega Sign or equivalent make) with finishing with gypsum material in 10 to 13 millimeter thickness to previously plastered surface/ or on newly brick surface (Excluding rough cast plaster) in all position including preparing and Finishing the surface scaffolding etc. complete. First Floor

6067.21

-

-

... More
Providing and applying gypsum plaster (with Gypsum material of Gypsum India/ Mega Sign or equivalent make) with finishing with gypsum material in 10 to 13 millimeter thickness to previously plastered surface/ or on newly brick surface (Excluding rough cast plaster) in all position including preparing and Finishing the surface scaffolding etc. complete. Second Floor

5464.38

-

-

... More
Providing and applying gypsum plaster (with Gypsum material of Gypsum India/ Mega Sign or equivalent make) with finishing with gypsum material in 10 to 13 millimeter thickness to previously plastered surface/ or on newly brick surface (Excluding rough cast plaster) in all position including preparing and Finishing the surface scaffolding etc. complete. Third Floor

6141.23

-

-

... More
Providing and applying gypsum plaster (with Gypsum material of Gypsum India/ Mega Sign or equivalent make) with finishing with gypsum material in 10 to 13 millimeter thickness to previously plastered surface/ or on newly brick surface (Excluding rough cast plaster) in all position including preparing and Finishing the surface scaffolding etc. complete. Fourth Floor

6911.41

-

-

... More
Providing and applying gypsum plaster (with Gypsum material of Gypsum India/ Mega Sign or equivalent make) with finishing with gypsum material in 10 to 13 millimeter thickness to previously plastered surface/ or on newly brick surface (Excluding rough cast plaster) in all position including preparing and Finishing the surface scaffolding etc. complete. Fifth Floor

1599.23

-

-

... More
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 milimetre thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 milimetre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc. complete. Ground Floor

8612.32

-

-

... More
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 milimetre thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 milimetre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc. complete. First Floor

3454.53

-

-

... More
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 milimetre thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 milimetre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc. complete. Second Floor

3190.49

-

-

... More
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 milimetre thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 milimetre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc. complete. Third Floor

3245.03

-

-

... More
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 milimetre thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 milimetre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc. complete. Fourth Floor

4978.17

-

-

... More
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 milimetre thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 milimetre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc. complete. Fifth Floor

2354.76

-

-

... More
Providing rough cast cement plaster externally in two coats to concrete, brick or stone masonry surfaces in all positions with base coat of 12 to 15 milimetre thick in cement mortar 1:4 and rough cast treatment 12 milimetre thick in proportion 1:1.5:3 including scaffolding and fourteen days curing complete. Ground Floor

20.43

-

-

... More
Providing rough cast cement plaster externally in two coats to concrete, brick or stone masonry surfaces in all positions with base coat of 12 to 15 milimetre thick in cement mortar 1:4 and rough cast treatment 12 milimetre thick in proportion 1:1.5:3 including scaffolding and fourteen days curing complete. First Floor

20.43

-

-

... More
Providing rough cast cement plaster externally in two coats to concrete, brick or stone masonry surfaces in all positions with base coat of 12 to 15 milimetre thick in cement mortar 1:4 and rough cast treatment 12 milimetre thick in proportion 1:1.5:3 including scaffolding and fourteen days curing complete. Second Floor

31.5

-

-

... More
Providing rough cast cement plaster externally in two coats to concrete, brick or stone masonry surfaces in all positions with base coat of 12 to 15 milimetre thick in cement mortar 1:4 and rough cast treatment 12 milimetre thick in proportion 1:1.5:3 including scaffolding and fourteen days curing complete. Third Floor

31.5

-

-

... More
Providing rough cast cement plaster externally in two coats to concrete, brick or stone masonry surfaces in all positions with base coat of 12 to 15 milimetre thick in cement mortar 1:4 and rough cast treatment 12 milimetre thick in proportion 1:1.5:3 including scaffolding and fourteen days curing complete. Fourth Floor

31.5

-

-

... More
Dry wall cladding with clay tile; Designing, supplying and fixing of Clay tile of Wienerberger (Red Series or Grey Series) or Equivalent with suitable size and thickness not less than 20 mm as per manufacturer with approved colour and pattern with composition of finest powdered clay and colour mixtures. The clay tile shall be fixed on the suitable farming system by using continuous aluminium profiled section as per manufacturer with suitable size and spacing to withstand the structural design criteria specifled in the technical specification by using necessary HDG brackets, SS316 grade anchor bolts etc as per manufacturer specification. Cladding joints should be with open groove system. with prior approval of concerned Superitending Engineer. Ground Floor

20.43

-

-

... More
Dry wall cladding with clay tile; Designing, supplying and fixing of Clay tile of Wienerberger (Red Series or Grey Series) or Equivalent with suitable size and thickness not less than 20 mm as per manufacturer with approved colour and pattern with composition of finest powdered clay and colour mixtures. The clay tile shall be fixed on the suitable farming system by using continuous aluminium profiled section as per manufacturer with suitable size and spacing to withstand the structural design criteria specifled in the technical specification by using necessary HDG brackets, SS316 grade anchor bolts etc as per manufacturer specification. Cladding joints should be with open groove system. with prior approval of concerned Superitending Engineer. First Floor

20.43

-

-

... More
Dry wall cladding with clay tile; Designing, supplying and fixing of Clay tile of Wienerberger (Red Series or Grey Series) or Equivalent with suitable size and thickness not less than 20 mm as per manufacturer with approved colour and pattern with composition of finest powdered clay and colour mixtures. The clay tile shall be fixed on the suitable farming system by using continuous aluminium profiled section as per manufacturer with suitable size and spacing to withstand the structural design criteria specifled in the technical specification by using necessary HDG brackets, SS316 grade anchor bolts etc as per manufacturer specification. Cladding joints should be with open groove system. with prior approval of concerned Superitending Engineer. Second Floor

20.43

-

-

... More
Dry wall cladding with clay tile; Designing, supplying and fixing of Clay tile of Wienerberger (Red Series or Grey Series) or Equivalent with suitable size and thickness not less than 20 mm as per manufacturer with approved colour and pattern with composition of finest powdered clay and colour mixtures. The clay tile shall be fixed on the suitable farming system by using continuous aluminium profiled section as per manufacturer with suitable size and spacing to withstand the structural design criteria specifled in the technical specification by using necessary HDG brackets, SS316 grade anchor bolts etc as per manufacturer specification. Cladding joints should be with open groove system. with prior approval of concerned Superitending Engineer. Third Floor

20.43

-

-

... More
Dry wall cladding with clay tile; Designing, supplying and fixing of Clay tile of Wienerberger (Red Series or Grey Series) or Equivalent with suitable size and thickness not less than 20 mm as per manufacturer with approved colour and pattern with composition of finest powdered clay and colour mixtures. The clay tile shall be fixed on the suitable farming system by using continuous aluminium profiled section as per manufacturer with suitable size and spacing to withstand the structural design criteria specifled in the technical specification by using necessary HDG brackets, SS316 grade anchor bolts etc as per manufacturer specification. Cladding joints should be with open groove system. with prior approval of concerned Superitending Engineer. Fourth Floor

20.43

-

-

... More
Providing and applying Royale Luxury Emulsion of Asian/ Berger/ Nerolac/ Dulux Paints or equivalent make on internal wall surface as detailed below Scrapping for surface with emery paper and wipe clean for area. Applying Asian/ Berger/ Nerolac/ Dulux Paints or equivalent wall primer with brush by adding mineral turpentine oil by 8 to 10 % or water by 15 to 20% allowing to dry for 6 to 8 hoursAfter applying Asian/ Berger/ Nerolac/ Dulux Paints or equivalent acrylic wall putty with appropriate prpportion of water of allow to dry for period of 4 to 6 hours of activity. Scrapping with emery paper and wipe clean Applying paints Royale Luxury emulsion 1st coat with brush water content water 40 to 45% or 65 to 70% by role Applying paints Royale luxury emulsion 2nd coat with brush with water content 40 to 45 % or 65 to 70 % by roller (With prior approval of S.E.). Ground Floor

5079

-

-

... More
Providing and applying Royale Luxury Emulsion of Asian/ Berger/ Nerolac/ Dulux Paints or equivalent make on internal wall surface as detailed below Scrapping for surface with emery paper and wipe clean for area. Applying Asian/ Berger/ Nerolac/ Dulux Paints or equivalent wall primer with brush by adding mineral turpentine oil by 8 to 10 % or water by 15 to 20% allowing to dry for 6 to 8 hoursAfter applying Asian/ Berger/ Nerolac/ Dulux Paints or equivalent acrylic wall putty with appropriate prpportion of water of allow to dry for period of 4 to 6 hours of activity. Scrapping with emery paper and wipe clean Applying paints Royale Luxury emulsion 1st coat with brush water content water 40 to 45% or 65 to 70% by role Applying paints Royale luxury emulsion 2nd coat with brush with water content 40 to 45 % or 65 to 70 % by roller (With prior approval of S.E.). First Floor

4445.14

-

-

... More
Providing and applying Royale Luxury Emulsion of Asian/ Berger/ Nerolac/ Dulux Paints or equivalent make on internal wall surface as detailed below Scrapping for surface with emery paper and wipe clean for area. Applying Asian/ Berger/ Nerolac/ Dulux Paints or equivalent wall primer with brush by adding mineral turpentine oil by 8 to 10 % or water by 15 to 20% allowing to dry for 6 to 8 hoursAfter applying Asian/ Berger/ Nerolac/ Dulux Paints or equivalent acrylic wall putty with appropriate prpportion of water of allow to dry for period of 4 to 6 hours of activity. Scrapping with emery paper and wipe clean Applying paints Royale Luxury emulsion 1st coat with brush water content water 40 to 45% or 65 to 70% by role Applying paints Royale luxury emulsion 2nd coat with brush with water content 40 to 45 % or 65 to 70 % by roller (With prior approval of S.E.). Second Floor

3842.31

-

-

... More
Providing and applying Royale Luxury Emulsion of Asian/ Berger/ Nerolac/ Dulux Paints or equivalent make on internal wall surface as detailed below Scrapping for surface with emery paper and wipe clean for area. Applying Asian/ Berger/ Nerolac/ Dulux Paints or equivalent wall primer with brush by adding mineral turpentine oil by 8 to 10 % or water by 15 to 20% allowing to dry for 6 to 8 hoursAfter applying Asian/ Berger/ Nerolac/ Dulux Paints or equivalent acrylic wall putty with appropriate prpportion of water of allow to dry for period of 4 to 6 hours of activity. Scrapping with emery paper and wipe clean Applying paints Royale Luxury emulsion 1st coat with brush water content water 40 to 45% or 65 to 70% by role Applying paints Royale luxury emulsion 2nd coat with brush with water content 40 to 45 % or 65 to 70 % by roller (With prior approval of S.E.). Third Floor

4492.52

-

-

... More
Providing and applying Royale Luxury Emulsion of Asian/ Berger/ Nerolac/ Dulux Paints or equivalent make on internal wall surface as detailed below Scrapping for surface with emery paper and wipe clean for area. Applying Asian/ Berger/ Nerolac/ Dulux Paints or equivalent wall primer with brush by adding mineral turpentine oil by 8 to 10 % or water by 15 to 20% allowing to dry for 6 to 8 hoursAfter applying Asian/ Berger/ Nerolac/ Dulux Paints or equivalent acrylic wall putty with appropriate prpportion of water of allow to dry for period of 4 to 6 hours of activity. Scrapping with emery paper and wipe clean Applying paints Royale Luxury emulsion 1st coat with brush water content water 40 to 45% or 65 to 70% by role Applying paints Royale luxury emulsion 2nd coat with brush with water content 40 to 45 % or 65 to 70 % by roller (With prior approval of S.E.). Fourth Floor

5201.39

-

-

... More
Providing and applying Royale Luxury Emulsion of Asian/ Berger/ Nerolac/ Dulux Paints or equivalent make on internal wall surface as detailed below Scrapping for surface with emery paper and wipe clean for area. Applying Asian/ Berger/ Nerolac/ Dulux Paints or equivalent wall primer with brush by adding mineral turpentine oil by 8 to 10 % or water by 15 to 20% allowing to dry for 6 to 8 hoursAfter applying Asian/ Berger/ Nerolac/ Dulux Paints or equivalent acrylic wall putty with appropriate prpportion of water of allow to dry for period of 4 to 6 hours of activity. Scrapping with emery paper and wipe clean Applying paints Royale Luxury emulsion 1st coat with brush water content water 40 to 45% or 65 to 70% by role Applying paints Royale luxury emulsion 2nd coat with brush with water content 40 to 45 % or 65 to 70 % by roller (With prior approval of S.E.). Fifth Floor

366.28

-

-

... More
Providing and applying pearl/ luster finish paint of approved colour and shade to the existing plastered surface including scaffolding preparing the surface applying acrylic wall putti etc. complete. Ground Floor

2152.34

-

-

... More
Providing and applying pearl/ luster finish paint of approved colour and shade to the existing plastered surface including scaffolding preparing the surface applying acrylic wall putti etc. complete. First Floor

4662.63

-

-

... More
Providing and applying pearl/ luster finish paint of approved colour and shade to the existing plastered surface including scaffolding preparing the surface applying acrylic wall putti etc. complete. Second Floor

4398.58

-

-

... More
Providing and applying pearl/ luster finish paint of approved colour and shade to the existing plastered surface including scaffolding preparing the surface applying acrylic wall putti etc. complete. Third Floor

4664.53

-

-

... More
Providing and applying pearl/ luster finish paint of approved colour and shade to the existing plastered surface including scaffolding preparing the surface applying acrylic wall putti etc. complete. Fourth Floor

4509.7

-

-

... More
Providing and applying pearl/ luster finish paint of approved colour and shade to the existing plastered surface including scaffolding preparing the surface applying acrylic wall putti etc. complete. Fifth Floor

1521.93

-

-

... More
Providing and applying two coats Apex Ultima Puranature Anti-Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC’s, CO, SOx, formaldehydes, etc.) in presence of natural or artificial light. It contains Graphene and nanoparticles of ium oxide. and Absorbs CO2 (4.8 kg/15 l). plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recommended applicator and he should be able to furnish stage wise onsite technical reports from the concerned company technologist. Ground Floor

8612.32

-

-

... More
Providing and applying two coats Apex Ultima Puranature Anti-Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC’s, CO, SOx, formaldehydes, etc.) in presence of natural or artificial light. It contains Graphene and nanoparticles of ium oxide. and Absorbs CO2 (4.8 kg/15 l). plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recommended applicator and he should be able to furnish stage wise onsite technical reports from the concerned company technologist. First Floor

3454.53

-

-

... More
Providing and applying two coats Apex Ultima Puranature Anti-Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC’s, CO, SOx, formaldehydes, etc.) in presence of natural or artificial light. It contains Graphene and nanoparticles of ium oxide. and Absorbs CO2 (4.8 kg/15 l). plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recommended applicator and he should be able to furnish stage wise onsite technical reports from the concerned company technologist. Second Floor

3190.49

-

-

... More
Providing and applying two coats Apex Ultima Puranature Anti-Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC’s, CO, SOx, formaldehydes, etc.) in presence of natural or artificial light. It contains Graphene and nanoparticles of ium oxide. and Absorbs CO2 (4.8 kg/15 l). plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recommended applicator and he should be able to furnish stage wise onsite technical reports from the concerned company technologist. Third Floor

2882.78

-

-

... More
Providing and applying two coats Apex Ultima Puranature Anti-Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC’s, CO, SOx, formaldehydes, etc.) in presence of natural or artificial light. It contains Graphene and nanoparticles of ium oxide. and Absorbs CO2 (4.8 kg/15 l). plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recommended applicator and he should be able to furnish stage wise onsite technical reports from the concerned company technologist. Fourth Floor

4978.17

-

-

... More
Providing and applying two coats Apex Ultima Puranature Anti-Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC’s, CO, SOx, formaldehydes, etc.) in presence of natural or artificial light. It contains Graphene and nanoparticles of ium oxide. and Absorbs CO2 (4.8 kg/15 l). plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recommended applicator and he should be able to furnish stage wise onsite technical reports from the concerned company technologist. Fifth Floor

2354.76

-

-

... More
Provinding and fixing aluminium grill diamond mesh type DG-202 of 7.5 milimetre thick including fixing in position anodised aluminium frame section of 80 x 38 milimetre x 1.22 milimetre size box, cutting to the required size with all wastage, labour, lead lift complete. Ground Floor

320.58

-

-

... More
Provinding and fixing aluminium grill diamond mesh type DG-202 of 7.5 milimetre thick including fixing in position anodised aluminium frame section of 80 x 38 milimetre x 1.22 milimetre size box, cutting to the required size with all wastage, labour, lead lift complete. First Floor

320.58

-

-

... More
Provinding and fixing aluminium grill diamond mesh type DG-202 of 7.5 milimetre thick including fixing in position anodised aluminium frame section of 80 x 38 milimetre x 1.22 milimetre size box, cutting to the required size with all wastage, labour, lead lift complete. Second Floor

320.58

-

-

... More
Provinding and fixing aluminium grill diamond mesh type DG-202 of 7.5 milimetre thick including fixing in position anodised aluminium frame section of 80 x 38 milimetre x 1.22 milimetre size box, cutting to the required size with all wastage, labour, lead lift complete. Third Floor

320.58

-

-

... More
Provinding and fixing aluminium grill diamond mesh type DG-202 of 7.5 milimetre thick including fixing in position anodised aluminium frame section of 80 x 38 milimetre x 1.22 milimetre size box, cutting to the required size with all wastage, labour, lead lift complete. Fourth Floor

320.58

-

-

... More
Providing and Fixing Sun Louvre panels roll formed, 0.6 milimetre thick, pre-painted stove enameled aluminium strip of a corrosion resistant alloy, including necessary fitting etc. complete, as directed by Engineer in Charge. Ground Floor

310.35

-

-

... More
Providing and Fixing Sun Louvre panels roll formed, 0.6 milimetre thick, pre-painted stove enameled aluminium strip of a corrosion resistant alloy, including necessary fitting etc. complete, as directed by Engineer in Charge. First Floor

321.47

-

-

... More
Providing and Fixing Sun Louvre panels roll formed, 0.6 milimetre thick, pre-painted stove enameled aluminium strip of a corrosion resistant alloy, including necessary fitting etc. complete, as directed by Engineer in Charge. Second Floor

440.42

-

-

... More
Providing and Fixing Sun Louvre panels roll formed, 0.6 milimetre thick, pre-painted stove enameled aluminium strip of a corrosion resistant alloy, including necessary fitting etc. complete, as directed by Engineer in Charge. Third Floor

440.42

-

-

... More
Providing and Fixing Sun Louvre panels roll formed, 0.6 milimetre thick, pre-painted stove enameled aluminium strip of a corrosion resistant alloy, including necessary fitting etc. complete, as directed by Engineer in Charge. Fourth Floor

440.42

-

-

... More
Providing and Fixing Sun Louvre panels roll formed, 0.6 milimetre thick, pre-painted stove enameled aluminium strip of a corrosion resistant alloy, including necessary fitting etc. complete, as directed by Engineer in Charge. Fifth Floor

76.35

-

-

... More
Providing and fixing 20 to 25 milimetre thick rough shahabad box type waterproofing for basement or underground floor on a base of Cement concrete 1:3:6, including sub base of 2.50 centimetre thick Cement mortar 1:3 with conceal, setcrete (RMW), Algaeproof or other alike water proofing liquids, raking of joints upto 35 milimetre depth,filling the joints with 6 milimetre size crushed metal, hand grouting with cement slurry, curing and cleaning, with 7 years guarantee on court fee stamp of Rs. 100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete).

588.38

-

-

... More
Providing and fixing 20 to 25 milimetre thick rough shahabad box type waterproofing treatment to vertical outside faces of Reinforced Cement concrete walls of basement or underground floor including filling the gap of 25 milimetre between rough shahabad and Reinforced Cement concrete walls with cement grout mixed with water proofing liquid Algaeproof or other alike with one tile lift method, brushing the joints horizontally with cement slurry mixed with water proofing liquid for width 30 to 35 milimetre and sloping coping over topmost tile with cement mortar 1:3, butting the bottom most with Cement concrete 1:2:4 mixed with water proofing liquid, curing, with 7 years guarantee on court fee stamp of Rs. 100/- with ponding test etc complete. (excluding Cement concrtete 1:3:6 base concrete).

488.22

-

-

... More
Providing and applying a base coat comprising of 1 kilogram Polydee-MC and 1 kilogram fresh cement after wetting the surface followed by drying the surface for 2 days, apply primer coat of TP-40 and after drying, applying Polydee-11 two component (mixing ratio 2 A: 1 B) Antibactorial food grade coating inside drinking watertank in two coats with time interval of minimum 8 hours covering 7 years guarantee on Court Fee Stamp Paper of Rs.100/- etc complete.

862.43

-

-

... More
Providing water proof bedding for flooring of bath and water closet, 25 milimetre thick in cement mortar 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete. Ground Floor

98.17

-

-

... More
Providing water proof bedding for flooring of bath and water closet, 25 milimetre thick in cement mortar 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete. First Floor

345.75

-

-

... More
Providing water proof bedding for flooring of bath and water closet, 25 milimetre thick in cement mortar 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete. Second Floor

322.96

-

-

... More
Providing water proof bedding for flooring of bath and water closet, 25 milimetre thick in cement mortar 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete. Third Floor

363.6

-

-

... More
Providing water proof bedding for flooring of bath and water closet, 25 milimetre thick in cement mortar 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete. Fourth Floor

254.39

-

-

... More
Providing water proof bedding for flooring of bath and water closet, 25 milimetre thick in cement mortar 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete. Fifth Floor

16.2

-

-

... More
Providing waterproofing in Water Closet and bath including brick bat coba in all position including providing and laying 12 milimetre bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound at the rate of 1kg/ per bag of cement laying brick bat coba of required thickness in cm 1:5 with waterproofing compound 1 kilogram per bag of cement grouting and finishing the top layer with 20 milimetre thick brick bedding in cement mortor 1:3 with waterproofing compound 1 kilogram per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etc. complete. Ground Floor

23.92

-

-

... More
Providing waterproofing in Water Closet and bath including brick bat coba in all position including providing and laying 12 milimetre bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound at the rate of 1kg/ per bag of cement laying brick bat coba of required thickness in cm 1:5 with waterproofing compound 1 kilogram per bag of cement grouting and finishing the top layer with 20 milimetre thick brick bedding in cement mortor 1:3 with waterproofing compound 1 kilogram per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etc. complete. First Floor

99

-

-

... More
Providing waterproofing in Water Closet and bath including brick bat coba in all position including providing and laying 12 milimetre bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound at the rate of 1kg/ per bag of cement laying brick bat coba of required thickness in cm 1:5 with waterproofing compound 1 kilogram per bag of cement grouting and finishing the top layer with 20 milimetre thick brick bedding in cement mortor 1:3 with waterproofing compound 1 kilogram per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etc. complete. Second Floor

93.88

-

-

... More
Providing waterproofing in Water Closet and bath including brick bat coba in all position including providing and laying 12 milimetre bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound at the rate of 1kg/ per bag of cement laying brick bat coba of required thickness in cm 1:5 with waterproofing compound 1 kilogram per bag of cement grouting and finishing the top layer with 20 milimetre thick brick bedding in cement mortor 1:3 with waterproofing compound 1 kilogram per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etc. complete. Third Floor

84.06

-

-

... More
Providing waterproofing in Water Closet and bath including brick bat coba in all position including providing and laying 12 milimetre bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound at the rate of 1kg/ per bag of cement laying brick bat coba of required thickness in cm 1:5 with waterproofing compound 1 kilogram per bag of cement grouting and finishing the top layer with 20 milimetre thick brick bedding in cement mortor 1:3 with waterproofing compound 1 kilogram per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etc. complete. Fourth Floor

76.92

-

-

... More
Providing waterproofing in Water Closet and bath including brick bat coba in all position including providing and laying 12 milimetre bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound at the rate of 1kg/ per bag of cement laying brick bat coba of required thickness in cm 1:5 with waterproofing compound 1 kilogram per bag of cement grouting and finishing the top layer with 20 milimetre thick brick bedding in cement mortor 1:3 with waterproofing compound 1 kilogram per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etc. complete. Fifth Floor

14.4

-

-

... More
Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in cement mortar 1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with cement mortar1:3 admixed with approved water proofing compound and finally top finishing with average 20 milimetre thick layers of same mortar added with jute fiber at 1 kilogram per bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300 milimetre x 300 milimetre making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete. Ground Floor

15.68

-

-

... More
Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in cement mortar 1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with cement mortar1:3 admixed with approved water proofing compound and finally top finishing with average 20 milimetre thick layers of same mortar added with jute fiber at 1 kilogram per bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300 milimetre x 300 milimetre making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete. First Floor

452.29

-

-

... More
Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in cement mortar 1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with cement mortar1:3 admixed with approved water proofing compound and finally top finishing with average 20 milimetre thick layers of same mortar added with jute fiber at 1 kilogram per bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300 milimetre x 300 milimetre making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete. Second Floor

105

-

-

... More
Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in cement mortar 1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with cement mortar1:3 admixed with approved water proofing compound and finally top finishing with average 20 milimetre thick layers of same mortar added with jute fiber at 1 kilogram per bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300 milimetre x 300 milimetre making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete. Third Floor

105

-

-

... More
Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in cement mortar 1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with cement mortar1:3 admixed with approved water proofing compound and finally top finishing with average 20 milimetre thick layers of same mortar added with jute fiber at 1 kilogram per bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300 milimetre x 300 milimetre making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete. Fourth Floor

3455.57

-

-

... More
Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in cement mortar 1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with cement mortar1:3 admixed with approved water proofing compound and finally top finishing with average 20 milimetre thick layers of same mortar added with jute fiber at 1 kilogram per bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300 milimetre x 300 milimetre making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete. Fifth Floor

971.91

-

-

... More
Providing and laying in position flooring of telephone black/ Amba White/ Cat bary brown/ Ruby red/ Ocean Brown granite stone of approved shade and size 18 milimetre to 20 milimetre thick on bed 1:6 cement mortar including cement floats striking joints, pointing in Cement Mortar 1:3 curing and cleaning etc. complete. Ground Floor

1512.53

-

-

... More
Providing and laying in position flooring of telephone black/ Amba White/ Cat bary brown/ Ruby red/ Ocean Brown granite stone of approved shade and size 18 milimetre to 20 milimetre thick on bed 1:6 cement mortar including cement floats striking joints, pointing in Cement Mortar 1:3 curing and cleaning etc. complete. First Floor

967.86

-

-

... More
Providing and laying in position flooring of telephone black/ Amba White/ Cat bary brown/ Ruby red/ Ocean Brown granite stone of approved shade and size 18 milimetre to 20 milimetre thick on bed 1:6 cement mortar including cement floats striking joints, pointing in Cement Mortar 1:3 curing and cleaning etc. complete. Second Floor

656.03

-

-

... More
Providing and laying in position flooring of telephone black/ Amba White/ Cat bary brown/ Ruby red/ Ocean Brown granite stone of approved shade and size 18 milimetre to 20 milimetre thick on bed 1:6 cement mortar including cement floats striking joints, pointing in Cement Mortar 1:3 curing and cleaning etc. complete. Third Floor

956.39

-

-

... More
Providing and laying in position flooring of telephone black/ Amba White/ Cat bary brown/ Ruby red/ Ocean Brown granite stone of approved shade and size 18 milimetre to 20 milimetre thick on bed 1:6 cement mortar including cement floats striking joints, pointing in Cement Mortar 1:3 curing and cleaning etc. complete. Fourth Floor

781.73

-

-

... More
Providing and laying in position flooring of telephone black/ Amba White/ Cat bary brown/ Ruby red/ Ocean Brown granite stone of approved shade and size 18 milimetre to 20 milimetre thick on bed 1:6 cement mortar including cement floats striking joints, pointing in Cement Mortar 1:3 curing and cleaning etc. complete. Fifth Floor

60.17

-

-

... More
Providing and fixing machine cut machine polished 18 milimetre to 20 milimetre thick telephone black/ Amba White/ Cat bary brown/ Ruby Red/ Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete. Ground Floor

271.27

-

-

... More
Providing and fixing machine cut machine polished 18 milimetre to 20 milimetre thick telephone black/ Amba White/ Cat bary brown/ Ruby Red/ Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete. First Floor

177.39

-

-

... More
Providing and fixing machine cut machine polished 18 milimetre to 20 milimetre thick telephone black/ Amba White/ Cat bary brown/ Ruby Red/ Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete. Second Floor

169.29

-

-

... More
Providing and fixing machine cut machine polished 18 milimetre to 20 milimetre thick telephone black/ Amba White/ Cat bary brown/ Ruby Red/ Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete. Third Floor

169.29

-

-

... More
Providing and fixing machine cut machine polished 18 milimetre to 20 milimetre thick telephone black/ Amba White/ Cat bary brown/ Ruby Red/ Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete. Fourth Floor

169.29

-

-

... More
Providing and fixing machine cut machine polished 18 milimetre to 20 milimetre thick telephone black/ Amba White/ Cat bary brown/ Ruby Red/ Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete. Fifth Floor

40.5

-

-

... More
Providing and laying telephone black/ Amba White/ Cadbury Brown/ Ruby red/ Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. on Cement Mortar 1:6 including filling joints with polymer base filler nosing the sharp edges wherever necessary, curing, etc. complete. Ground Floor

982.81

-

-

... More
Providing and laying telephone black/ Amba White/ Cadbury Brown/ Ruby red/ Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. on Cement Mortar 1:6 including filling joints with polymer base filler nosing the sharp edges wherever necessary, curing, etc. complete. First Floor

1072.19

-

-

... More
Providing and laying telephone black/ Amba White/ Cadbury Brown/ Ruby red/ Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. on Cement Mortar 1:6 including filling joints with polymer base filler nosing the sharp edges wherever necessary, curing, etc. complete. Second Floor

1029.13

-

-

... More
Providing and laying telephone black/ Amba White/ Cadbury Brown/ Ruby red/ Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. on Cement Mortar 1:6 including filling joints with polymer base filler nosing the sharp edges wherever necessary, curing, etc. complete. Third Floor

1178.35

-

-

... More
Providing and laying telephone black/ Amba White/ Cadbury Brown/ Ruby red/ Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. on Cement Mortar 1:6 including filling joints with polymer base filler nosing the sharp edges wherever necessary, curing, etc. complete. Fourth Floor

1222.63

-

-

... More
Providing and laying telephone black/ Amba White/ Cadbury Brown/ Ruby red/ Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. on Cement Mortar 1:6 including filling joints with polymer base filler nosing the sharp edges wherever necessary, curing, etc. complete. Fifth Floor

198.42

-

-

... More
Providing leather finished polishing to Granite Stone slab by continuous grinding in 4 coats of different bits to receive rough and matt finish including buffing process before laying and fixing of stone as per drawing and design, including cleaning, washing and finishing etc. complete. Ground Floor

293.72

-

-

... More
Providing leather finished polishing to Granite Stone slab by continuous grinding in 4 coats of different bits to receive rough and matt finish including buffing process before laying and fixing of stone as per drawing and design, including cleaning, washing and finishing etc. complete. First Floor

225.62

-

-

... More
Providing leather finished polishing to Granite Stone slab by continuous grinding in 4 coats of different bits to receive rough and matt finish including buffing process before laying and fixing of stone as per drawing and design, including cleaning, washing and finishing etc. complete. Second Floor

202.78

-

-

... More
Providing leather finished polishing to Granite Stone slab by continuous grinding in 4 coats of different bits to receive rough and matt finish including buffing process before laying and fixing of stone as per drawing and design, including cleaning, washing and finishing etc. complete. Third Floor

202.78

-

-

... More
Providing leather finished polishing to Granite Stone slab by continuous grinding in 4 coats of different bits to receive rough and matt finish including buffing process before laying and fixing of stone as per drawing and design, including cleaning, washing and finishing etc. complete. Fourth Floor

202.78

-

-

... More
Providing leather finished polishing to Granite Stone slab by continuous grinding in 4 coats of different bits to receive rough and matt finish including buffing process before laying and fixing of stone as per drawing and design, including cleaning, washing and finishing etc. complete. Fifth Floor

88.34

-

-

... More
Providing and laying polished Kotah stone flooring 25 millimeter to 30 millimeter thick and of reqd. width in plain/ diamond pattern on a bed of 1:6 cement mortar including cement float,filling joints with neat cement slurry,curing,polishing and cleaning complete. Ground Floor

171.67

-

-

... More
Providing and laying polished Kotah stone flooring 25 millimeter to 30 millimeter thick and of reqd. width in plain/ diamond pattern on a bed of 1:6 cement mortar including cement float,filling joints with neat cement slurry,curing,polishing and cleaning complete. First Floor

214.42

-

-

... More
Providing and laying polished Kotah stone flooring 25 millimeter to 30 millimeter thick and of reqd. width in plain/ diamond pattern on a bed of 1:6 cement mortar including cement float,filling joints with neat cement slurry,curing,polishing and cleaning complete. Second Floor

201.25

-

-

... More
Providing and laying polished Kotah stone flooring 25 millimeter to 30 millimeter thick and of reqd. width in plain/ diamond pattern on a bed of 1:6 cement mortar including cement float,filling joints with neat cement slurry,curing,polishing and cleaning complete. Third Floor

194.47

-

-

... More
Providing and laying polished Kotah stone flooring 25 millimeter to 30 millimeter thick and of reqd. width in plain/ diamond pattern on a bed of 1:6 cement mortar including cement float,filling joints with neat cement slurry,curing,polishing and cleaning complete. Fourth Floor

29.26

-

-

... More
Providing and fixing 1.5 milimetre thick polyvenyl venyl chloride flooring including leveling the base with white cement including pasting with appropriate material cleaning the surface etc. complete Ground Floor

142.22

-

-

... More
Providing and fixing 1.5 milimetre thick polyvenyl venyl chloride flooring including leveling the base with white cement including pasting with appropriate material cleaning the surface etc. complete First Floor

185.16

-

-

... More
Providing and fixing 1.5 milimetre thick polyvenyl venyl chloride flooring including leveling the base with white cement including pasting with appropriate material cleaning the surface etc. complete Second Floor

175.12

-

-

... More
Providing and fixing 1.5 milimetre thick polyvenyl venyl chloride flooring including leveling the base with white cement including pasting with appropriate material cleaning the surface etc. complete Third Floor

165.21

-

-

... More
Providing and laying vitrified matt fininsh tiles for flooring having size 590 milimetre to 605 milimetre of 8 to 10 milimetre thickness and confirming Indian Standard 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete. Ground Floor

1292.82

-

-

... More
Providing and laying vitrified matt fininsh tiles for flooring having size 590 milimetre to 605 milimetre of 8 to 10 milimetre thickness and confirming Indian Standard 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete. First Floor

1404.73

-

-

... More
Providing and laying vitrified matt fininsh tiles for flooring having size 590 milimetre to 605 milimetre of 8 to 10 milimetre thickness and confirming Indian Standard 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete. Second Floor

1369.18

-

-

... More
Providing and laying vitrified matt fininsh tiles for flooring having size 590 milimetre to 605 milimetre of 8 to 10 milimetre thickness and confirming Indian Standard 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete. Third Floor

1477.22

-

-

... More
Providing and laying vitrified matt fininsh tiles for flooring having size 590 milimetre to 605 milimetre of 8 to 10 milimetre thickness and confirming Indian Standard 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete. Fourth Floor

1580.55

-

-

... More
Providing and laying vitrified matt finish tiles for Skirting having size 590 milimetre to 605 milimetre x to 605 milimetre of 8 to 10 mm thickness and confirming Indian Standard 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. Ground Floor

1501.47

-

-

... More
Providing and laying vitrified matt finish tiles for Skirting having size 590 milimetre to 605 milimetre x to 605 milimetre of 8 to 10 mm thickness and confirming Indian Standard 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. First Floor

2083.07

-

-

... More
Providing and laying vitrified matt finish tiles for Skirting having size 590 milimetre to 605 milimetre x to 605 milimetre of 8 to 10 mm thickness and confirming Indian Standard 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. Second Floor

1936.45

-

-

... More
Providing and laying vitrified matt finish tiles for Skirting having size 590 milimetre to 605 milimetre x to 605 milimetre of 8 to 10 mm thickness and confirming Indian Standard 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. Third Floor

2275.18

-

-

... More
Providing and laying vitrified matt finish tiles for Skirting having size 590 milimetre to 605 milimetre x to 605 milimetre of 8 to 10 mm thickness and confirming Indian Standard 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. Fourth Floor

1708.96

-

-

... More
Providing and laying in situ cement concrete M-20 with tremix treatment for 100 milimetre thickness for flooring with groove cutting of 4 milimetre wide and 20 milimetre deep with necessary refilling with bitumen etc. complete.

646.61

-

-

... More
Providing and fixing 15 milimetre thick eco-friendly densified edge calcium silicate fall ceiling (like aeroltie) of approved texture spintone/cosmos/hexa or equivalent of size 595 milimetre x 595 milimetre in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections (galvanising at the rate 12 gram per square metre including both sides) consisting of main “T” runner suitably spaced at joints to get required length and size 24 x 38 milimetre made from 0.33 milimetre thick (minimum ) sheet, spaced 1200 milimetre center to center and cross “T” of size 24x28 milimetre made of 0.33 milimetre thick (minimum ) sheet to be interlocked at the middle of the 1200 x 600 milimetre panel to form the grid of size 600 x 600 milimetre resting on periphery walls/partitions on a perimeter wall angle precoated steel of size 24 x24x 3000 made of 0.4 milimetre thick (minimum) sheet with the help of all plugs at 450 milimetre and laying 15 milimetre thick densified edges calcium silicate ceiling tiles of approved texture (spintone/ cosmos/ hexa) in the grid, including light fittings, fixtures, smoke detectors, wherever required. Main “T” runners suspended from ceiling with using Galvanised Iron slotted cleats of size 25x35x1.6 milimetre fixed to ceiling using 12.5 milimetre diametre and 50 milimetre long dash fasteners, 4 milimetre Galvanised Iron adjustable rods with galvanized steel levels clips of size 85x30x0.8 milimetre, spaced at 1200 milimetre center to center along main “T” bottom exposed with 24 milimetre of all T-sections shall be prepainted with polyester baked paint, for all heights, as per specifications, drawings complete. (currently this item should be used only for VIP cabins). Ground Floor

31.27

-

-

... More
Providing and fixing 15 milimetre thick eco-friendly densified edge calcium silicate fall ceiling (like aeroltie) of approved texture spintone/cosmos/hexa or equivalent of size 595 milimetre x 595 milimetre in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections (galvanising at the rate 12 gram per square metre including both sides) consisting of main “T” runner suitably spaced at joints to get required length and size 24 x 38 milimetre made from 0.33 milimetre thick (minimum ) sheet, spaced 1200 milimetre center to center and cross “T” of size 24x28 milimetre made of 0.33 milimetre thick (minimum ) sheet to be interlocked at the middle of the 1200 x 600 milimetre panel to form the grid of size 600 x 600 milimetre resting on periphery walls/partitions on a perimeter wall angle precoated steel of size 24 x24x 3000 made of 0.4 milimetre thick (minimum) sheet with the help of all plugs at 450 milimetre and laying 15 milimetre thick densified edges calcium silicate ceiling tiles of approved texture (spintone/ cosmos/ hexa) in the grid, including light fittings, fixtures, smoke detectors, wherever required. Main “T” runners suspended from ceiling with using Galvanised Iron slotted cleats of size 25x35x1.6 milimetre fixed to ceiling using 12.5 milimetre diametre and 50 milimetre long dash fasteners, 4 milimetre Galvanised Iron adjustable rods with galvanized steel levels clips of size 85x30x0.8 milimetre, spaced at 1200 milimetre center to center along main “T” bottom exposed with 24 milimetre of all T-sections shall be prepainted with polyester baked paint, for all heights, as per specifications, drawings complete. (currently this item should be used only for VIP cabins). First Floor

127.18

-

-

... More
Providing and fixing 15 milimetre thick eco-friendly densified edge calcium silicate fall ceiling (like aeroltie) of approved texture spintone/cosmos/hexa or equivalent of size 595 milimetre x 595 milimetre in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections (galvanising at the rate 12 gram per square metre including both sides) consisting of main “T” runner suitably spaced at joints to get required length and size 24 x 38 milimetre made from 0.33 milimetre thick (minimum ) sheet, spaced 1200 milimetre center to center and cross “T” of size 24x28 milimetre made of 0.33 milimetre thick (minimum ) sheet to be interlocked at the middle of the 1200 x 600 milimetre panel to form the grid of size 600 x 600 milimetre resting on periphery walls/partitions on a perimeter wall angle precoated steel of size 24 x24x 3000 made of 0.4 milimetre thick (minimum) sheet with the help of all plugs at 450 milimetre and laying 15 milimetre thick densified edges calcium silicate ceiling tiles of approved texture (spintone/ cosmos/ hexa) in the grid, including light fittings, fixtures, smoke detectors, wherever required. Main “T” runners suspended from ceiling with using Galvanised Iron slotted cleats of size 25x35x1.6 milimetre fixed to ceiling using 12.5 milimetre diametre and 50 milimetre long dash fasteners, 4 milimetre Galvanised Iron adjustable rods with galvanized steel levels clips of size 85x30x0.8 milimetre, spaced at 1200 milimetre center to center along main “T” bottom exposed with 24 milimetre of all T-sections shall be prepainted with polyester baked paint, for all heights, as per specifications, drawings complete. (currently this item should be used only for VIP cabins). Second Floor

86.19

-

-

... More
Providing and fixing 15 milimetre thick eco-friendly densified edge calcium silicate fall ceiling (like aeroltie) of approved texture spintone/cosmos/hexa or equivalent of size 595 milimetre x 595 milimetre in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections (galvanising at the rate 12 gram per square metre including both sides) consisting of main “T” runner suitably spaced at joints to get required length and size 24 x 38 milimetre made from 0.33 milimetre thick (minimum ) sheet, spaced 1200 milimetre center to center and cross “T” of size 24x28 milimetre made of 0.33 milimetre thick (minimum ) sheet to be interlocked at the middle of the 1200 x 600 milimetre panel to form the grid of size 600 x 600 milimetre resting on periphery walls/partitions on a perimeter wall angle precoated steel of size 24 x24x 3000 made of 0.4 milimetre thick (minimum) sheet with the help of all plugs at 450 milimetre and laying 15 milimetre thick densified edges calcium silicate ceiling tiles of approved texture (spintone/ cosmos/ hexa) in the grid, including light fittings, fixtures, smoke detectors, wherever required. Main “T” runners suspended from ceiling with using Galvanised Iron slotted cleats of size 25x35x1.6 milimetre fixed to ceiling using 12.5 milimetre diametre and 50 milimetre long dash fasteners, 4 milimetre Galvanised Iron adjustable rods with galvanized steel levels clips of size 85x30x0.8 milimetre, spaced at 1200 milimetre center to center along main “T” bottom exposed with 24 milimetre of all T-sections shall be prepainted with polyester baked paint, for all heights, as per specifications, drawings complete. (currently this item should be used only for VIP cabins). Third Floor

206.19

-

-

... More
Providing and fixing 15 milimetre thick eco-friendly densified edge calcium silicate fall ceiling (like aeroltie) of approved texture spintone/cosmos/hexa or equivalent of size 595 milimetre x 595 milimetre in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections (galvanising at the rate 12 gram per square metre including both sides) consisting of main “T” runner suitably spaced at joints to get required length and size 24 x 38 milimetre made from 0.33 milimetre thick (minimum ) sheet, spaced 1200 milimetre center to center and cross “T” of size 24x28 milimetre made of 0.33 milimetre thick (minimum ) sheet to be interlocked at the middle of the 1200 x 600 milimetre panel to form the grid of size 600 x 600 milimetre resting on periphery walls/partitions on a perimeter wall angle precoated steel of size 24 x24x 3000 made of 0.4 milimetre thick (minimum) sheet with the help of all plugs at 450 milimetre and laying 15 milimetre thick densified edges calcium silicate ceiling tiles of approved texture (spintone/ cosmos/ hexa) in the grid, including light fittings, fixtures, smoke detectors, wherever required. Main “T” runners suspended from ceiling with using Galvanised Iron slotted cleats of size 25x35x1.6 milimetre fixed to ceiling using 12.5 milimetre diametre and 50 milimetre long dash fasteners, 4 milimetre Galvanised Iron adjustable rods with galvanized steel levels clips of size 85x30x0.8 milimetre, spaced at 1200 milimetre center to center along main “T” bottom exposed with 24 milimetre of all T-sections shall be prepainted with polyester baked paint, for all heights, as per specifications, drawings complete. (currently this item should be used only for VIP cabins). Fourth Floor

83.03

-

-

... More
Providing and Fixing of Armstrong or equivalent Mineral Fibre Acoustical Suspended Ceiling System with ultima (Bevelled Tegular) Edge Tiles With Armstrong or equivalent 15 milimetre Exposed GRID. The tiles should have Humidity Resistance (RH) of 99 percent, NRC 0.7, Light Reflectance ≥85 percent, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 and 7) in module size of 600 x 600 x 20 milimetre, suitable for Green Building application, with Recycled content of 32 percent.The tile shall be laid on precoated Galvanised Iron channel on XL2 Clip having a web height of 32 milimetre with 15 milimetre wide T- section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 milimetre and 600 milimetre Cross Tees with a web height of 32 milimetre and a load carrying capacity of 7.7 Kilogramme per square metre and minimum pull out strength of 100 Kilogram. The T Sections have a Galvanizing of 90 grams per square metre and need to be installed with Suspension system of Armstrong or equivalent make. . The Tile and Grid system used together should carry a 10 year warranty. products approved as per GRIHA and BS :476 Ground Floor

824.65

-

-

... More
Providing and Fixing of Armstrong or equivalent Mineral Fibre Acoustical Suspended Ceiling System with ultima (Bevelled Tegular) Edge Tiles With Armstrong or equivalent 15 milimetre Exposed GRID. The tiles should have Humidity Resistance (RH) of 99 percent, NRC 0.7, Light Reflectance ≥85 percent, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 and 7) in module size of 600 x 600 x 20 milimetre, suitable for Green Building application, with Recycled content of 32 percent.The tile shall be laid on precoated Galvanised Iron channel on XL2 Clip having a web height of 32 milimetre with 15 milimetre wide T- section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 milimetre and 600 milimetre Cross Tees with a web height of 32 milimetre and a load carrying capacity of 7.7 Kilogramme per square metre and minimum pull out strength of 100 Kilogram. The T Sections have a Galvanizing of 90 grams per square metre and need to be installed with Suspension system of Armstrong or equivalent make. . The Tile and Grid system used together should carry a 10 year warranty. products approved as per GRIHA and BS :476 First Floor

303.82

-

-

... More
Providing and Fixing of Armstrong or equivalent Mineral Fibre Acoustical Suspended Ceiling System with ultima (Bevelled Tegular) Edge Tiles With Armstrong or equivalent 15 milimetre Exposed GRID. The tiles should have Humidity Resistance (RH) of 99 percent, NRC 0.7, Light Reflectance ≥85 percent, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 and 7) in module size of 600 x 600 x 20 milimetre, suitable for Green Building application, with Recycled content of 32 percent.The tile shall be laid on precoated Galvanised Iron channel on XL2 Clip having a web height of 32 milimetre with 15 milimetre wide T- section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 milimetre and 600 milimetre Cross Tees with a web height of 32 milimetre and a load carrying capacity of 7.7 Kilogramme per square metre and minimum pull out strength of 100 Kilogram. The T Sections have a Galvanizing of 90 grams per square metre and need to be installed with Suspension system of Armstrong or equivalent make. . The Tile and Grid system used together should carry a 10 year warranty. products approved as per GRIHA and BS :476 Second Floor

262.06

-

-

... More
Providing and Fixing of Armstrong or equivalent Mineral Fibre Acoustical Suspended Ceiling System with ultima (Bevelled Tegular) Edge Tiles With Armstrong or equivalent 15 milimetre Exposed GRID. The tiles should have Humidity Resistance (RH) of 99 percent, NRC 0.7, Light Reflectance ≥85 percent, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 and 7) in module size of 600 x 600 x 20 milimetre, suitable for Green Building application, with Recycled content of 32 percent.The tile shall be laid on precoated Galvanised Iron channel on XL2 Clip having a web height of 32 milimetre with 15 milimetre wide T- section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 milimetre and 600 milimetre Cross Tees with a web height of 32 milimetre and a load carrying capacity of 7.7 Kilogramme per square metre and minimum pull out strength of 100 Kilogram. The T Sections have a Galvanizing of 90 grams per square metre and need to be installed with Suspension system of Armstrong or equivalent make. . The Tile and Grid system used together should carry a 10 year warranty. products approved as per GRIHA and BS :476 Third Floor

171.83

-

-

... More
Providing and Fixing of Armstrong or equivalent Mineral Fibre Acoustical Suspended Ceiling System with ultima (Bevelled Tegular) Edge Tiles With Armstrong or equivalent 15 milimetre Exposed GRID. The tiles should have Humidity Resistance (RH) of 99 percent, NRC 0.7, Light Reflectance ≥85 percent, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 and 7) in module size of 600 x 600 x 20 milimetre, suitable for Green Building application, with Recycled content of 32 percent.The tile shall be laid on precoated Galvanised Iron channel on XL2 Clip having a web height of 32 milimetre with 15 milimetre wide T- section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 milimetre and 600 milimetre Cross Tees with a web height of 32 milimetre and a load carrying capacity of 7.7 Kilogramme per square metre and minimum pull out strength of 100 Kilogram. The T Sections have a Galvanizing of 90 grams per square metre and need to be installed with Suspension system of Armstrong or equivalent make. . The Tile and Grid system used together should carry a 10 year warranty. products approved as per GRIHA and BS :476 Fourth Floor

231.58

-

-

... More
Providing and fixing in position Gypsum board false ceiling with 12.5 milimetre thick Gypsum boards, screwed/ fixed to the under structure of suspended galvanised iron Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 milimetre maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete. Ground Floor

274.86

-

-

... More
Providing and fixing in position Gypsum board false ceiling with 12.5 milimetre thick Gypsum boards, screwed/ fixed to the under structure of suspended galvanised iron Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 milimetre maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete. First Floor

36.92

-

-

... More
Providing and fixing in position Gypsum board false ceiling with 12.5 milimetre thick Gypsum boards, screwed/ fixed to the under structure of suspended galvanised iron Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 milimetre maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete. Second Floor

36.92

-

-

... More
Providing and fixing in position Gypsum board false ceiling with 12.5 milimetre thick Gypsum boards, screwed/ fixed to the under structure of suspended galvanised iron Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 milimetre maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete. Third Floor

20.21

-

-

... More
Providing and fixing in position Gypsum board false ceiling with 12.5 milimetre thick Gypsum boards, screwed/ fixed to the under structure of suspended galvanised iron Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 milimetre maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete. Fourth Floor

87.65

-

-

... More
FALSE CEILING SYSTEM GI METAL BIOGUARD CLIP IN PLAIN TILE WITH CARRIER SYSTEM 600 X 600MM Providing & Fixing horizontal level suspended ceiling comprising of GI Bioguard Clip-in Plain Tile 600x600mm (Nominal Size) tiles of 120 gsm galvanized steel as per IS 277 (2003) suitable for architectural finishes in 0.5mm thickness as per in IS:513 (1994) in Global white color with concealed suspension system having a bevelled edge of 3x3mm and height of 33mm on one side and 18mm on the other side. Tiles shall be flattened by precision leveller to minimize sag to less than 1/400mm. The tiles shall have double round pip of ɸ 2mm and ɸ 6mm for secure engagement and levelling respectively, along with swing down feature and special tabs to allow removal of tile to enable plenum access. The coated surface of the tile shall exhibit anti-microbial properties (eradication and inhibition of growth) and shall achieve up to 99.99% reduction in bacterial activity as per ISO22196:2011. The tile shall be electrostatically polyester powder coated using RoHS compliant powder having coating thickness ranging from 60-80 microns. The powder coating shall pass Salt Spray Test for 750 Hours as per ASTM B117, QUV –A Test for 1000hours as per ASTM G- 154 – (Cycle – 1) and Humidity test for 1000hours as per DIN 50017. The powder coating shall have an adhesion of GT0 as per EN ISO 2409. The shade variation across batches shall be delta E1 using Excite/BYK Gardner instrument and gloss level of 25±5% at 60˚ as per ASTM D523. The tile shall have scratch, mar & abrasive resistance properties. The tile shall have a Light Reflectance of ≥ 63% in accordance to ASTM 1477-98 and Fire Performance of class 0/1 as per BS 476 Part 6 & 7 in module size of 600x600mm. SUSPENSION & INSTALLATION: Shall comprise of 3000mm long ‗C‘ channels of 38H x 12W mm and 1mm thick spaced at 1200mm centre to centre securely fixed to the structural soffit using threaded rod (Approved make/Third Party Supply) connecting to C-channel hanger of 109x18.5x16.5mm at 1200mm C/C and anchor fastener (Approved make/Third Party Supply). The last hanger at the end of each C-channel shall not be greater than 600mm from the adjacent wall. Use a C-channel connector of 99.5x35x 9mm for splicing together two pieces of C-channels. 4000mm Clip-in bar of 16W x 40H mm and 0.6mm thick made of galvanized steel of 140gsm as IS 277 (2003) and shall be spaced at 600mm centre to centre in a direction perpendicular to the C-channels and secured at every intersection with C-channel using a Clip-in bar hanger of 54x18x20mm. Use Clip-in bar connecter to splice two pieces of Clip-in bar. Tiles shall be clipped in between two Clip-in bars from below. Optionally - Security clip to be installed to ensure the panels are positively engaged with Clip-in bar channel. Installation shall be carried out as per Manufacturer recommended procedure. Perimeter to be finished using wall angles of size 3000x19x32mm in white color secured to walls using screws at 450mm centre to centre. Cut tiles to be secured to the wall angles using a spring clamp. The Tile & Grid system used together shall carry a 10 year warranty against manufacturing defect and manufacturer shall provide a warranty certificate. The Tile & Grid shall have the manufacturers name embossed/printed on it. The supply shall be backed by a Manufacturing Test Certificate. Ground Floor

139.88

-

-

... More
FALSE CEILING SYSTEM GI METAL BIOGUARD CLIP IN PLAIN TILE WITH CARRIER SYSTEM 600 X 600MM Providing & Fixing horizontal level suspended ceiling comprising of GI Bioguard Clip-in Plain Tile 600x600mm (Nominal Size) tiles of 120 gsm galvanized steel as per IS 277 (2003) suitable for architectural finishes in 0.5mm thickness as per in IS:513 (1994) in Global white color with concealed suspension system having a bevelled edge of 3x3mm and height of 33mm on one side and 18mm on the other side. Tiles shall be flattened by precision leveller to minimize sag to less than 1/400mm. The tiles shall have double round pip of ɸ 2mm and ɸ 6mm for secure engagement and levelling respectively, along with swing down feature and special tabs to allow removal of tile to enable plenum access. The coated surface of the tile shall exhibit anti-microbial properties (eradication and inhibition of growth) and shall achieve up to 99.99% reduction in bacterial activity as per ISO22196:2011. The tile shall be electrostatically polyester powder coated using RoHS compliant powder having coating thickness ranging from 60-80 microns. The powder coating shall pass Salt Spray Test for 750 Hours as per ASTM B117, QUV –A Test for 1000hours as per ASTM G- 154 – (Cycle – 1) and Humidity test for 1000hours as per DIN 50017. The powder coating shall have an adhesion of GT0 as per EN ISO 2409. The shade variation across batches shall be delta E1 using Excite/BYK Gardner instrument and gloss level of 25±5% at 60˚ as per ASTM D523. The tile shall have scratch, mar & abrasive resistance properties. The tile shall have a Light Reflectance of ≥ 63% in accordance to ASTM 1477-98 and Fire Performance of class 0/1 as per BS 476 Part 6 & 7 in module size of 600x600mm. SUSPENSION & INSTALLATION: Shall comprise of 3000mm long ‗C‘ channels of 38H x 12W mm and 1mm thick spaced at 1200mm centre to centre securely fixed to the structural soffit using threaded rod (Approved make/Third Party Supply) connecting to C-channel hanger of 109x18.5x16.5mm at 1200mm C/C and anchor fastener (Approved make/Third Party Supply). The last hanger at the end of each C-channel shall not be greater than 600mm from the adjacent wall. Use a C-channel connector of 99.5x35x 9mm for splicing together two pieces of C-channels. 4000mm Clip-in bar of 16W x 40H mm and 0.6mm thick made of galvanized steel of 140gsm as IS 277 (2003) and shall be spaced at 600mm centre to centre in a direction perpendicular to the C-channels and secured at every intersection with C-channel using a Clip-in bar hanger of 54x18x20mm. Use Clip-in bar connecter to splice two pieces of Clip-in bar. Tiles shall be clipped in between two Clip-in bars from below. Optionally - Security clip to be installed to ensure the panels are positively engaged with Clip-in bar channel. Installation shall be carried out as per Manufacturer recommended procedure. Perimeter to be finished using wall angles of size 3000x19x32mm in white color secured to walls using screws at 450mm centre to centre. Cut tiles to be secured to the wall angles using a spring clamp. The Tile & Grid system used together shall carry a 10 year warranty against manufacturing defect and manufacturer shall provide a warranty certificate. The Tile & Grid shall have the manufacturers name embossed/printed on it. The supply shall be backed by a Manufacturing Test Certificate. First Floor

185.16

-

-

... More
FALSE CEILING SYSTEM GI METAL BIOGUARD CLIP IN PLAIN TILE WITH CARRIER SYSTEM 600 X 600MM Providing & Fixing horizontal level suspended ceiling comprising of GI Bioguard Clip-in Plain Tile 600x600mm (Nominal Size) tiles of 120 gsm galvanized steel as per IS 277 (2003) suitable for architectural finishes in 0.5mm thickness as per in IS:513 (1994) in Global white color with concealed suspension system having a bevelled edge of 3x3mm and height of 33mm on one side and 18mm on the other side. Tiles shall be flattened by precision leveller to minimize sag to less than 1/400mm. The tiles shall have double round pip of ɸ 2mm and ɸ 6mm for secure engagement and levelling respectively, along with swing down feature and special tabs to allow removal of tile to enable plenum access. The coated surface of the tile shall exhibit anti-microbial properties (eradication and inhibition of growth) and shall achieve up to 99.99% reduction in bacterial activity as per ISO22196:2011. The tile shall be electrostatically polyester powder coated using RoHS compliant powder having coating thickness ranging from 60-80 microns. The powder coating shall pass Salt Spray Test for 750 Hours as per ASTM B117, QUV –A Test for 1000hours as per ASTM G- 154 – (Cycle – 1) and Humidity test for 1000hours as per DIN 50017. The powder coating shall have an adhesion of GT0 as per EN ISO 2409. The shade variation across batches shall be delta E1 using Excite/BYK Gardner instrument and gloss level of 25±5% at 60˚ as per ASTM D523. The tile shall have scratch, mar & abrasive resistance properties. The tile shall have a Light Reflectance of ≥ 63% in accordance to ASTM 1477-98 and Fire Performance of class 0/1 as per BS 476 Part 6 & 7 in module size of 600x600mm. SUSPENSION & INSTALLATION: Shall comprise of 3000mm long ‗C‘ channels of 38H x 12W mm and 1mm thick spaced at 1200mm centre to centre securely fixed to the structural soffit using threaded rod (Approved make/Third Party Supply) connecting to C-channel hanger of 109x18.5x16.5mm at 1200mm C/C and anchor fastener (Approved make/Third Party Supply). The last hanger at the end of each C-channel shall not be greater than 600mm from the adjacent wall. Use a C-channel connector of 99.5x35x 9mm for splicing together two pieces of C-channels. 4000mm Clip-in bar of 16W x 40H mm and 0.6mm thick made of galvanized steel of 140gsm as IS 277 (2003) and shall be spaced at 600mm centre to centre in a direction perpendicular to the C-channels and secured at every intersection with C-channel using a Clip-in bar hanger of 54x18x20mm. Use Clip-in bar connecter to splice two pieces of Clip-in bar. Tiles shall be clipped in between two Clip-in bars from below. Optionally - Security clip to be installed to ensure the panels are positively engaged with Clip-in bar channel. Installation shall be carried out as per Manufacturer recommended procedure. Perimeter to be finished using wall angles of size 3000x19x32mm in white color secured to walls using screws at 450mm centre to centre. Cut tiles to be secured to the wall angles using a spring clamp. The Tile & Grid system used together shall carry a 10 year warranty against manufacturing defect and manufacturer shall provide a warranty certificate. The Tile & Grid shall have the manufacturers name embossed/printed on it. The supply shall be backed by a Manufacturing Test Certificate. Second Floor

52.27

-

-

... More
FALSE CEILING SYSTEM GI METAL BIOGUARD CLIP IN PLAIN TILE WITH CARRIER SYSTEM 600 X 600MM Providing & Fixing horizontal level suspended ceiling comprising of GI Bioguard Clip-in Plain Tile 600x600mm (Nominal Size) tiles of 120 gsm galvanized steel as per IS 277 (2003) suitable for architectural finishes in 0.5mm thickness as per in IS:513 (1994) in Global white color with concealed suspension system having a bevelled edge of 3x3mm and height of 33mm on one side and 18mm on the other side. Tiles shall be flattened by precision leveller to minimize sag to less than 1/400mm. The tiles shall have double round pip of ɸ 2mm and ɸ 6mm for secure engagement and levelling respectively, along with swing down feature and special tabs to allow removal of tile to enable plenum access. The coated surface of the tile shall exhibit anti-microbial properties (eradication and inhibition of growth) and shall achieve up to 99.99% reduction in bacterial activity as per ISO22196:2011. The tile shall be electrostatically polyester powder coated using RoHS compliant powder having coating thickness ranging from 60-80 microns. The powder coating shall pass Salt Spray Test for 750 Hours as per ASTM B117, QUV –A Test for 1000hours as per ASTM G- 154 – (Cycle – 1) and Humidity test for 1000hours as per DIN 50017. The powder coating shall have an adhesion of GT0 as per EN ISO 2409. The shade variation across batches shall be delta E1 using Excite/BYK Gardner instrument and gloss level of 25±5% at 60˚ as per ASTM D523. The tile shall have scratch, mar & abrasive resistance properties. The tile shall have a Light Reflectance of ≥ 63% in accordance to ASTM 1477-98 and Fire Performance of class 0/1 as per BS 476 Part 6 & 7 in module size of 600x600mm. SUSPENSION & INSTALLATION: Shall comprise of 3000mm long ‗C‘ channels of 38H x 12W mm and 1mm thick spaced at 1200mm centre to centre securely fixed to the structural soffit using threaded rod (Approved make/Third Party Supply) connecting to C-channel hanger of 109x18.5x16.5mm at 1200mm C/C and anchor fastener (Approved make/Third Party Supply). The last hanger at the end of each C-channel shall not be greater than 600mm from the adjacent wall. Use a C-channel connector of 99.5x35x 9mm for splicing together two pieces of C-channels. 4000mm Clip-in bar of 16W x 40H mm and 0.6mm thick made of galvanized steel of 140gsm as IS 277 (2003) and shall be spaced at 600mm centre to centre in a direction perpendicular to the C-channels and secured at every intersection with C-channel using a Clip-in bar hanger of 54x18x20mm. Use Clip-in bar connecter to splice two pieces of Clip-in bar. Tiles shall be clipped in between two Clip-in bars from below. Optionally - Security clip to be installed to ensure the panels are positively engaged with Clip-in bar channel. Installation shall be carried out as per Manufacturer recommended procedure. Perimeter to be finished using wall angles of size 3000x19x32mm in white color secured to walls using screws at 450mm centre to centre. Cut tiles to be secured to the wall angles using a spring clamp. The Tile & Grid system used together shall carry a 10 year warranty against manufacturing defect and manufacturer shall provide a warranty certificate. The Tile & Grid shall have the manufacturers name embossed/printed on it. The supply shall be backed by a Manufacturing Test Certificate. Third Floor

165.21

-

-

... More
FALSE CEILING SYSTEM GI METAL BIOGUARD CLIP IN PLAIN TILE WITH CARRIER SYSTEM 600 X 600MM Providing & Fixing horizontal level suspended ceiling comprising of GI Bioguard Clip-in Plain Tile 600x600mm (Nominal Size) tiles of 120 gsm galvanized steel as per IS 277 (2003) suitable for architectural finishes in 0.5mm thickness as per in IS:513 (1994) in Global white color with concealed suspension system having a bevelled edge of 3x3mm and height of 33mm on one side and 18mm on the other side. Tiles shall be flattened by precision leveller to minimize sag to less than 1/400mm. The tiles shall have double round pip of ɸ 2mm and ɸ 6mm for secure engagement and levelling respectively, along with swing down feature and special tabs to allow removal of tile to enable plenum access. The coated surface of the tile shall exhibit anti-microbial properties (eradication and inhibition of growth) and shall achieve up to 99.99% reduction in bacterial activity as per ISO22196:2011. The tile shall be electrostatically polyester powder coated using RoHS compliant powder having coating thickness ranging from 60-80 microns. The powder coating shall pass Salt Spray Test for 750 Hours as per ASTM B117, QUV –A Test for 1000hours as per ASTM G- 154 – (Cycle – 1) and Humidity test for 1000hours as per DIN 50017. The powder coating shall have an adhesion of GT0 as per EN ISO 2409. The shade variation across batches shall be delta E1 using Excite/BYK Gardner instrument and gloss level of 25±5% at 60˚ as per ASTM D523. The tile shall have scratch, mar & abrasive resistance properties. The tile shall have a Light Reflectance of ≥ 63% in accordance to ASTM 1477-98 and Fire Performance of class 0/1 as per BS 476 Part 6 & 7 in module size of 600x600mm. SUSPENSION & INSTALLATION: Shall comprise of 3000mm long ‗C‘ channels of 38H x 12W mm and 1mm thick spaced at 1200mm centre to centre securely fixed to the structural soffit using threaded rod (Approved make/Third Party Supply) connecting to C-channel hanger of 109x18.5x16.5mm at 1200mm C/C and anchor fastener (Approved make/Third Party Supply). The last hanger at the end of each C-channel shall not be greater than 600mm from the adjacent wall. Use a C-channel connector of 99.5x35x 9mm for splicing together two pieces of C-channels. 4000mm Clip-in bar of 16W x 40H mm and 0.6mm thick made of galvanized steel of 140gsm as IS 277 (2003) and shall be spaced at 600mm centre to centre in a direction perpendicular to the C-channels and secured at every intersection with C-channel using a Clip-in bar hanger of 54x18x20mm. Use Clip-in bar connecter to splice two pieces of Clip-in bar. Tiles shall be clipped in between two Clip-in bars from below. Optionally - Security clip to be installed to ensure the panels are positively engaged with Clip-in bar channel. Installation shall be carried out as per Manufacturer recommended procedure. Perimeter to be finished using wall angles of size 3000x19x32mm in white color secured to walls using screws at 450mm centre to centre. Cut tiles to be secured to the wall angles using a spring clamp. The Tile & Grid system used together shall carry a 10 year warranty against manufacturing defect and manufacturer shall provide a warranty certificate. The Tile & Grid shall have the manufacturers name embossed/printed on it. The supply shall be backed by a Manufacturing Test Certificate. Fourth Floor

31.4

-

-

... More
Providing and fixing frame with / without ventilator of size as specified with teak wood for doors and windows including chamferring, rounding, rebating, iron holdfast size 300 milimetre x 40 milimetre x 5 milimetre with oil painting complete. Ground Floor

4.53

-

-

... More
Providing and fixing frame with / without ventilator of size as specified with teak wood for doors and windows including chamferring, rounding, rebating, iron holdfast size 300 milimetre x 40 milimetre x 5 milimetre with oil painting complete. First Floor

7.02

-

-

... More
Providing and fixing frame with / without ventilator of size as specified with teak wood for doors and windows including chamferring, rounding, rebating, iron holdfast size 300 milimetre x 40 milimetre x 5 milimetre with oil painting complete. Second Floor

5.47

-

-

... More
Providing and fixing frame with / without ventilator of size as specified with teak wood for doors and windows including chamferring, rounding, rebating, iron holdfast size 300 milimetre x 40 milimetre x 5 milimetre with oil painting complete. Third Floor

6.81

-

-

... More
Providing and fixing frame with / without ventilator of size as specified with teak wood for doors and windows including chamferring, rounding, rebating, iron holdfast size 300 milimetre x 40 milimetre x 5 milimetre with oil painting complete. Fourth Floor

6.59

-

-

... More
Providing and fixing frame with / without ventilator of size as specified with teak wood for doors and windows including chamferring, rounding, rebating, iron holdfast size 300 milimetre x 40 milimetre x 5 milimetre with oil painting complete. Fifth Floor

1.79

-

-

... More
Providing and fixing in position U.P.V.C.(Unplasticized Poly Vinyl Chloride) having multi-chambered outer frame section (73 x 50) milimetre with an outer wall thickness of 2 milimetre & steel reinforcement, multi-chambered slider frame (73x 60) milimetre with steel reinforcement, multi-chambered slider sash (46x 82) milimetre with steel reinforcement designed to give optimum strength, 5 milimetre thick toughened double glass with 12 milimetre spacer of good quality including alluminium track, Inter-locking profile, coextruded beadings, EPDM gaskets,silicon sealent,sliding handle, fixtures and fastenings (couplings, hinges) including with all required screws and nuts with all necessary U.P.V.C. sections as per the detailed drawing and as directed by Engineer-In-Charge etc. complete. Ground Floor

77.35

-

-

... More
Providing and fixing in position U.P.V.C.(Unplasticized Poly Vinyl Chloride) having multi-chambered outer frame section (73 x 50) milimetre with an outer wall thickness of 2 milimetre & steel reinforcement, multi-chambered slider frame (73x 60) milimetre with steel reinforcement, multi-chambered slider sash (46x 82) milimetre with steel reinforcement designed to give optimum strength, 5 milimetre thick toughened double glass with 12 milimetre spacer of good quality including alluminium track, Inter-locking profile, coextruded beadings, EPDM gaskets,silicon sealent,sliding handle, fixtures and fastenings (couplings, hinges) including with all required screws and nuts with all necessary U.P.V.C. sections as per the detailed drawing and as directed by Engineer-In-Charge etc. complete. First Floor

187.91

-

-

... More
Providing and fixing in position U.P.V.C.(Unplasticized Poly Vinyl Chloride) having multi-chambered outer frame section (73 x 50) milimetre with an outer wall thickness of 2 milimetre & steel reinforcement, multi-chambered slider frame (73x 60) milimetre with steel reinforcement, multi-chambered slider sash (46x 82) milimetre with steel reinforcement designed to give optimum strength, 5 milimetre thick toughened double glass with 12 milimetre spacer of good quality including alluminium track, Inter-locking profile, coextruded beadings, EPDM gaskets,silicon sealent,sliding handle, fixtures and fastenings (couplings, hinges) including with all required screws and nuts with all necessary U.P.V.C. sections as per the detailed drawing and as directed by Engineer-In-Charge etc. complete. Second Floor

163.37

-

-

... More
Providing and fixing in position U.P.V.C.(Unplasticized Poly Vinyl Chloride) having multi-chambered outer frame section (73 x 50) milimetre with an outer wall thickness of 2 milimetre & steel reinforcement, multi-chambered slider frame (73x 60) milimetre with steel reinforcement, multi-chambered slider sash (46x 82) milimetre with steel reinforcement designed to give optimum strength, 5 milimetre thick toughened double glass with 12 milimetre spacer of good quality including alluminium track, Inter-locking profile, coextruded beadings, EPDM gaskets,silicon sealent,sliding handle, fixtures and fastenings (couplings, hinges) including with all required screws and nuts with all necessary U.P.V.C. sections as per the detailed drawing and as directed by Engineer-In-Charge etc. complete. Third Floor

184.32

-

-

... More
Providing and fixing in position factory made EPS cement sandwich wall/roof/floor light weight solid core pannel made of core material of EPS granule ball/beads (conforming to IS 4671:1984 and shall have density not less than 15 kg per cum) adhesive, cement,sand,flyash and other bonding material in mortar state processed to form in a preset mould. The outer face on both sides of the panels will be non asbestos fibre cement board confirming to IS 14862:2000 or Calcium Silicate Board confirming to EN 14306:2009 of 5 mm thick each Panels shall be laid on 6 mm thick cement mortar ( 1 cement : 2 fine sand)mixed with chemical adhesive of 0.5 Kg per 50 Kg of cement or shall be preferbly fixed into 'C' channel made of 1.2 mm thick MS plate screwed/fastenered to the salb/coloumn/beam etc. The Panel shall fixed vertically with tongue and groove joint and horizontally locked with steel bar between each other and floors and filled with cement mortar and adhesive. Panels should be used as floor and roofing with additional structure support, steel or RCC depending upon the design. All the operation shall be completed in all respect as per drawing, manufacturing specification and under the overall direction of Enginner-in-charge ( Cost oa all the material is included except 'C' channel which will be paid separtely) A) Non Load bearing panels 60 mm thick required size Ground Floor

43.2

-

-

... More
Providing and fixing in position factory made EPS cement sandwich wall/roof/floor light weight solid core pannel made of core material of EPS granule ball/beads (conforming to IS 4671:1984 and shall have density not less than 15 kg per cum) adhesive, cement,sand,flyash and other bonding material in mortar state processed to form in a preset mould. The outer face on both sides of the panels will be non asbestos fibre cement board confirming to IS 14862:2000 or Calcium Silicate Board confirming to EN 14306:2009 of 5 mm thick each Panels shall be laid on 6 mm thick cement mortar ( 1 cement : 2 fine sand)mixed with chemical adhesive of 0.5 Kg per 50 Kg of cement or shall be preferbly fixed into 'C' channel made of 1.2 mm thick MS plate screwed/fastenered to the salb/coloumn/beam etc. The Panel shall fixed vertically with tongue and groove joint and horizontally locked with steel bar between each other and floors and filled with cement mortar and adhesive. Panels should be used as floor and roofing with additional structure support, steel or RCC depending upon the design. All the operation shall be completed in all respect as per drawing, manufacturing specification and under the overall direction of Enginner-in-charge ( Cost oa all the material is included except 'C' channel which will be paid separtely) A) Non Load bearing panels 60 mm thick required size First Floor

43.2

-

-

... More
Providing and fixing in position factory made EPS cement sandwich wall/roof/floor light weight solid core pannel made of core material of EPS granule ball/beads (conforming to IS 4671:1984 and shall have density not less than 15 kg per cum) adhesive, cement,sand,flyash and other bonding material in mortar state processed to form in a preset mould. The outer face on both sides of the panels will be non asbestos fibre cement board confirming to IS 14862:2000 or Calcium Silicate Board confirming to EN 14306:2009 of 5 mm thick each Panels shall be laid on 6 mm thick cement mortar ( 1 cement : 2 fine sand)mixed with chemical adhesive of 0.5 Kg per 50 Kg of cement or shall be preferbly fixed into 'C' channel made of 1.2 mm thick MS plate screwed/fastenered to the salb/coloumn/beam etc. The Panel shall fixed vertically with tongue and groove joint and horizontally locked with steel bar between each other and floors and filled with cement mortar and adhesive. Panels should be used as floor and roofing with additional structure support, steel or RCC depending upon the design. All the operation shall be completed in all respect as per drawing, manufacturing specification and under the overall direction of Enginner-in-charge ( Cost oa all the material is included except 'C' channel which will be paid separtely) A) Non Load bearing panels 60 mm thick required size Second Floor

43.2

-

-

... More
Providing and fixing in position factory made EPS cement sandwich wall/roof/floor light weight solid core pannel made of core material of EPS granule ball/beads (conforming to IS 4671:1984 and shall have density not less than 15 kg per cum) adhesive, cement,sand,flyash and other bonding material in mortar state processed to form in a preset mould. The outer face on both sides of the panels will be non asbestos fibre cement board confirming to IS 14862:2000 or Calcium Silicate Board confirming to EN 14306:2009 of 5 mm thick each Panels shall be laid on 6 mm thick cement mortar ( 1 cement : 2 fine sand)mixed with chemical adhesive of 0.5 Kg per 50 Kg of cement or shall be preferbly fixed into 'C' channel made of 1.2 mm thick MS plate screwed/fastenered to the salb/coloumn/beam etc. The Panel shall fixed vertically with tongue and groove joint and horizontally locked with steel bar between each other and floors and filled with cement mortar and adhesive. Panels should be used as floor and roofing with additional structure support, steel or RCC depending upon the design. All the operation shall be completed in all respect as per drawing, manufacturing specification and under the overall direction of Enginner-in-charge ( Cost oa all the material is included except 'C' channel which will be paid separtely) A) Non Load bearing panels 60 mm thick required size Third Floor

43.2

-

-

... More
Providing and fixing in position factory made EPS cement sandwich wall/roof/floor light weight solid core pannel made of core material of EPS granule ball/beads (conforming to IS 4671:1984 and shall have density not less than 15 kg per cum) adhesive, cement,sand,flyash and other bonding material in mortar state processed to form in a preset mould. The outer face on both sides of the panels will be non asbestos fibre cement board confirming to IS 14862:2000 or Calcium Silicate Board confirming to EN 14306:2009 of 5 mm thick each Panels shall be laid on 6 mm thick cement mortar ( 1 cement : 2 fine sand)mixed with chemical adhesive of 0.5 Kg per 50 Kg of cement or shall be preferbly fixed into 'C' channel made of 1.2 mm thick MS plate screwed/fastenered to the salb/coloumn/beam etc. The Panel shall fixed vertically with tongue and groove joint and horizontally locked with steel bar between each other and floors and filled with cement mortar and adhesive. Panels should be used as floor and roofing with additional structure support, steel or RCC depending upon the design. All the operation shall be completed in all respect as per drawing, manufacturing specification and under the overall direction of Enginner-in-charge ( Cost oa all the material is included except 'C' channel which will be paid separtely) A) Non Load bearing panels 60 mm thick required size Fourth Floor

43.2

-

-

... More
Providing of 60 min Fire rated doors system duly tested for 3 criteria - Integrity, Insulation and Stability Criteria as per the IS: 3614 Part 2 and BS: 476 part 22 at National Test House, Govt of India laborator and/or with Central Building Research Institute, Govt of India undertaking with standard heating conditions as specified in IS:3614 Part II 1992 and BS: 476 part 20 & 22 1987 to achieve the required integrity, insulation and stability (i.e. to restrict the heat radiation, temperature rise on the non fire side to the maximum of 140° C above the ambient temperature on the exposed surface of the shutter. The fire doors are tested with NCBN technology ("Non Combustible by Nature"). with prior approval of concerned Superitending Engineer. b) Shutter : Providing of 65mm thick asbestos free composite - 3 criteria - fire, heat and smoke check Accoustic Door Shutter with flame guard of 120 minutes IS3614 part -II comprising of 2x9mm Calcium Silicate boards, Chemical treated internal timber with Fire retardant chemicals in pressure impregnation vessels under 160 PSI pressure as per IS:401and kiln seasoned to moisture below 15% as per IS:1141 frame work of 100x32 mm with 32mm thick infill of ceramic fiber (density 128Kgs/CMT), vermaculite mix faced with 6mm Fire retardant High Density ply, internally lipped with hardwood beading, and pasted in Hydraulic Press under 50 tonnes pressure, spray quoted with 2 coats of In tumescent paint of minimum 200 micron, and with 1 row of Brush- Type Astroflame® intumescent strip (imported) of size 10mmx4mm concealed for fire and smoke sealing in the grooves in the shutter on all edges except bottom, without any external lipping. Ground Floor

18

-

-

... More
Providing of 60 min Fire rated doors system duly tested for 3 criteria - Integrity, Insulation and Stability Criteria as per the IS: 3614 Part 2 and BS: 476 part 22 at National Test House, Govt of India laborator and/or with Central Building Research Institute, Govt of India undertaking with standard heating conditions as specified in IS:3614 Part II 1992 and BS: 476 part 20 & 22 1987 to achieve the required integrity, insulation and stability (i.e. to restrict the heat radiation, temperature rise on the non fire side to the maximum of 140° C above the ambient temperature on the exposed surface of the shutter. The fire doors are tested with NCBN technology ("Non Combustible by Nature"). with prior approval of concerned Superitending Engineer. b) Shutter : Providing of 65mm thick asbestos free composite - 3 criteria - fire, heat and smoke check Accoustic Door Shutter with flame guard of 120 minutes IS3614 part -II comprising of 2x9mm Calcium Silicate boards, Chemical treated internal timber with Fire retardant chemicals in pressure impregnation vessels under 160 PSI pressure as per IS:401and kiln seasoned to moisture below 15% as per IS:1141 frame work of 100x32 mm with 32mm thick infill of ceramic fiber (density 128Kgs/CMT), vermaculite mix faced with 6mm Fire retardant High Density ply, internally lipped with hardwood beading, and pasted in Hydraulic Press under 50 tonnes pressure, spray quoted with 2 coats of In tumescent paint of minimum 200 micron, and with 1 row of Brush- Type Astroflame® intumescent strip (imported) of size 10mmx4mm concealed for fire and smoke sealing in the grooves in the shutter on all edges except bottom, without any external lipping. First Floor

25.2

-

-

... More
Providing of 60 min Fire rated doors system duly tested for 3 criteria - Integrity, Insulation and Stability Criteria as per the IS: 3614 Part 2 and BS: 476 part 22 at National Test House, Govt of India laborator and/or with Central Building Research Institute, Govt of India undertaking with standard heating conditions as specified in IS:3614 Part II 1992 and BS: 476 part 20 & 22 1987 to achieve the required integrity, insulation and stability (i.e. to restrict the heat radiation, temperature rise on the non fire side to the maximum of 140° C above the ambient temperature on the exposed surface of the shutter. The fire doors are tested with NCBN technology ("Non Combustible by Nature"). with prior approval of concerned Superitending Engineer. b) Shutter : Providing of 65mm thick asbestos free composite - 3 criteria - fire, heat and smoke check Accoustic Door Shutter with flame guard of 120 minutes IS3614 part -II comprising of 2x9mm Calcium Silicate boards, Chemical treated internal timber with Fire retardant chemicals in pressure impregnation vessels under 160 PSI pressure as per IS:401and kiln seasoned to moisture below 15% as per IS:1141 frame work of 100x32 mm with 32mm thick infill of ceramic fiber (density 128Kgs/CMT), vermaculite mix faced with 6mm Fire retardant High Density ply, internally lipped with hardwood beading, and pasted in Hydraulic Press under 50 tonnes pressure, spray quoted with 2 coats of In tumescent paint of minimum 200 micron, and with 1 row of Brush- Type Astroflame® intumescent strip (imported) of size 10mmx4mm concealed for fire and smoke sealing in the grooves in the shutter on all edges except bottom, without any external lipping. Second Floor

10.8

-

-

... More
Providing of 60 min Fire rated doors system duly tested for 3 criteria - Integrity, Insulation and Stability Criteria as per the IS: 3614 Part 2 and BS: 476 part 22 at National Test House, Govt of India laborator and/or with Central Building Research Institute, Govt of India undertaking with standard heating conditions as specified in IS:3614 Part II 1992 and BS: 476 part 20 & 22 1987 to achieve the required integrity, insulation and stability (i.e. to restrict the heat radiation, temperature rise on the non fire side to the maximum of 140° C above the ambient temperature on the exposed surface of the shutter. The fire doors are tested with NCBN technology ("Non Combustible by Nature"). with prior approval of concerned Superitending Engineer. b) Shutter : Providing of 65mm thick asbestos free composite - 3 criteria - fire, heat and smoke check Accoustic Door Shutter with flame guard of 120 minutes IS3614 part -II comprising of 2x9mm Calcium Silicate boards, Chemical treated internal timber with Fire retardant chemicals in pressure impregnation vessels under 160 PSI pressure as per IS:401and kiln seasoned to moisture below 15% as per IS:1141 frame work of 100x32 mm with 32mm thick infill of ceramic fiber (density 128Kgs/CMT), vermaculite mix faced with 6mm Fire retardant High Density ply, internally lipped with hardwood beading, and pasted in Hydraulic Press under 50 tonnes pressure, spray quoted with 2 coats of In tumescent paint of minimum 200 micron, and with 1 row of Brush- Type Astroflame® intumescent strip (imported) of size 10mmx4mm concealed for fire and smoke sealing in the grooves in the shutter on all edges except bottom, without any external lipping. Third Floor

21.6

-

-

... More
Providing of 60 min Fire rated doors system duly tested for 3 criteria - Integrity, Insulation and Stability Criteria as per the IS: 3614 Part 2 and BS: 476 part 22 at National Test House, Govt of India laborator and/or with Central Building Research Institute, Govt of India undertaking with standard heating conditions as specified in IS:3614 Part II 1992 and BS: 476 part 20 & 22 1987 to achieve the required integrity, insulation and stability (i.e. to restrict the heat radiation, temperature rise on the non fire side to the maximum of 140° C above the ambient temperature on the exposed surface of the shutter. The fire doors are tested with NCBN technology ("Non Combustible by Nature"). with prior approval of concerned Superitending Engineer. b) Shutter : Providing of 65mm thick asbestos free composite - 3 criteria - fire, heat and smoke check Accoustic Door Shutter with flame guard of 120 minutes IS3614 part -II comprising of 2x9mm Calcium Silicate boards, Chemical treated internal timber with Fire retardant chemicals in pressure impregnation vessels under 160 PSI pressure as per IS:401and kiln seasoned to moisture below 15% as per IS:1141 frame work of 100x32 mm with 32mm thick infill of ceramic fiber (density 128Kgs/CMT), vermaculite mix faced with 6mm Fire retardant High Density ply, internally lipped with hardwood beading, and pasted in Hydraulic Press under 50 tonnes pressure, spray quoted with 2 coats of In tumescent paint of minimum 200 micron, and with 1 row of Brush- Type Astroflame® intumescent strip (imported) of size 10mmx4mm concealed for fire and smoke sealing in the grooves in the shutter on all edges except bottom, without any external lipping. Fourth Floor

10.8

-

-

... More
Providing and fixing of factory made uPVC Louver window (White Colour) comprising of uPVC multi-chambered with wall thickness of 2.3mm (+-0.2 mm ), duly reinforced with 1.5 mm thick G. I. Section. uPVC window & door profile shall be made in India & shall conform to BS EN 12608 and other standards as mentioned below: S.No. Name of the test Test Method Specifie Parameter 1 Tensile Impact Strength ISO 8256 - more than 700Kj/m2 2 Vicat Softening Temperature EN ISO – 306 Shall not be 750C 3 Charpy Impact Strength EN ISO – 179-2 Shall not be 20KJ/m2 4 Flexural Modulus Elasticity EN ISO – 178 Shall not be 2200 N/mm2 5 Mean Breaking Stress for welded corner (a) For the tensile bending test EN – 514 Shall not be 25 N/mm2 (b) For the compression bending test Shall not be 30N/mm2 6 Heat Reversion Test IS:4985-2000 Shall not be 2.0 % 7 Surface Spread of flame BS : 476 - Part 7 Classification 1 8 Ignitability Evaluation BS : 476 - Part 5 'P' Not easily ignitable 9 Tensile modulus ASTM D 638 Shall not be 35 MPa 10 Shear Modulus ASTM D 732 Shall not be 220 MPa 11 Tensile Strength EN ISO 527 Shall not be 30 MPa. All corners of frame shall be fusion welded. Both vertical sides of the frame, adjustable louver mechanism having one lever or fixed louver bracket shall be fitted with the of 4 mm Frosted Annealed glass. Window will be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge. uPVC Window and Door Profiles are warranted for a period of ten (10) years against non- uniform discoloration,wrapping and rotting under general use. a.Louver Window (Big Series) frame of size 67 x 62 mm & Mullion (if required) of size 67 x 78 mm. Ground Floor

6.48

-

-

... More
Providing and fixing of factory made uPVC Louver window (White Colour) comprising of uPVC multi-chambered with wall thickness of 2.3mm (+-0.2 mm ), duly reinforced with 1.5 mm thick G. I. Section. uPVC window & door profile shall be made in India & shall conform to BS EN 12608 and other standards as mentioned below: S.No. Name of the test Test Method Specifie Parameter 1 Tensile Impact Strength ISO 8256 - more than 700Kj/m2 2 Vicat Softening Temperature EN ISO – 306 Shall not be 750C 3 Charpy Impact Strength EN ISO – 179-2 Shall not be 20KJ/m2 4 Flexural Modulus Elasticity EN ISO – 178 Shall not be 2200 N/mm2 5 Mean Breaking Stress for welded corner (a) For the tensile bending test EN – 514 Shall not be 25 N/mm2 (b) For the compression bending test Shall not be 30N/mm2 6 Heat Reversion Test IS:4985-2000 Shall not be 2.0 % 7 Surface Spread of flame BS : 476 - Part 7 Classification 1 8 Ignitability Evaluation BS : 476 - Part 5 'P' Not easily ignitable 9 Tensile modulus ASTM D 638 Shall not be 35 MPa 10 Shear Modulus ASTM D 732 Shall not be 220 MPa 11 Tensile Strength EN ISO 527 Shall not be 30 MPa. All corners of frame shall be fusion welded. Both vertical sides of the frame, adjustable louver mechanism having one lever or fixed louver bracket shall be fitted with the of 4 mm Frosted Annealed glass. Window will be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge. uPVC Window and Door Profiles are warranted for a period of ten (10) years against non- uniform discoloration,wrapping and rotting under general use. a.Louver Window (Big Series) frame of size 67 x 62 mm & Mullion (if required) of size 67 x 78 mm. First Floor

11.88

-

-

... More
Providing and fixing of factory made uPVC Louver window (White Colour) comprising of uPVC multi-chambered with wall thickness of 2.3mm (+-0.2 mm ), duly reinforced with 1.5 mm thick G. I. Section. uPVC window & door profile shall be made in India & shall conform to BS EN 12608 and other standards as mentioned below: S.No. Name of the test Test Method Specifie Parameter 1 Tensile Impact Strength ISO 8256 - more than 700Kj/m2 2 Vicat Softening Temperature EN ISO – 306 Shall not be 750C 3 Charpy Impact Strength EN ISO – 179-2 Shall not be 20KJ/m2 4 Flexural Modulus Elasticity EN ISO – 178 Shall not be 2200 N/mm2 5 Mean Breaking Stress for welded corner (a) For the tensile bending test EN – 514 Shall not be 25 N/mm2 (b) For the compression bending test Shall not be 30N/mm2 6 Heat Reversion Test IS:4985-2000 Shall not be 2.0 % 7 Surface Spread of flame BS : 476 - Part 7 Classification 1 8 Ignitability Evaluation BS : 476 - Part 5 'P' Not easily ignitable 9 Tensile modulus ASTM D 638 Shall not be 35 MPa 10 Shear Modulus ASTM D 732 Shall not be 220 MPa 11 Tensile Strength EN ISO 527 Shall not be 30 MPa. All corners of frame shall be fusion welded. Both vertical sides of the frame, adjustable louver mechanism having one lever or fixed louver bracket shall be fitted with the of 4 mm Frosted Annealed glass. Window will be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge. uPVC Window and Door Profiles are warranted for a period of ten (10) years against non- uniform discoloration,wrapping and rotting under general use. a.Louver Window (Big Series) frame of size 67 x 62 mm & Mullion (if required) of size 67 x 78 mm. Second Floor

9.18

-

-

... More
Providing and fixing of factory made uPVC Louver window (White Colour) comprising of uPVC multi-chambered with wall thickness of 2.3mm (+-0.2 mm ), duly reinforced with 1.5 mm thick G. I. Section. uPVC window & door profile shall be made in India & shall conform to BS EN 12608 and other standards as mentioned below: S.No. Name of the test Test Method Specifie Parameter 1 Tensile Impact Strength ISO 8256 - more than 700Kj/m2 2 Vicat Softening Temperature EN ISO – 306 Shall not be 750C 3 Charpy Impact Strength EN ISO – 179-2 Shall not be 20KJ/m2 4 Flexural Modulus Elasticity EN ISO – 178 Shall not be 2200 N/mm2 5 Mean Breaking Stress for welded corner (a) For the tensile bending test EN – 514 Shall not be 25 N/mm2 (b) For the compression bending test Shall not be 30N/mm2 6 Heat Reversion Test IS:4985-2000 Shall not be 2.0 % 7 Surface Spread of flame BS : 476 - Part 7 Classification 1 8 Ignitability Evaluation BS : 476 - Part 5 'P' Not easily ignitable 9 Tensile modulus ASTM D 638 Shall not be 35 MPa 10 Shear Modulus ASTM D 732 Shall not be 220 MPa 11 Tensile Strength EN ISO 527 Shall not be 30 MPa. All corners of frame shall be fusion welded. Both vertical sides of the frame, adjustable louver mechanism having one lever or fixed louver bracket shall be fitted with the of 4 mm Frosted Annealed glass. Window will be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge. uPVC Window and Door Profiles are warranted for a period of ten (10) years against non- uniform discoloration,wrapping and rotting under general use. a.Louver Window (Big Series) frame of size 67 x 62 mm & Mullion (if required) of size 67 x 78 mm. Third Floor

8.1

-

-

... More
Providing and fixing of factory made uPVC Louver window (White Colour) comprising of uPVC multi-chambered with wall thickness of 2.3mm (+-0.2 mm ), duly reinforced with 1.5 mm thick G. I. Section. uPVC window & door profile shall be made in India & shall conform to BS EN 12608 and other standards as mentioned below: S.No. Name of the test Test Method Specifie Parameter 1 Tensile Impact Strength ISO 8256 - more than 700Kj/m2 2 Vicat Softening Temperature EN ISO – 306 Shall not be 750C 3 Charpy Impact Strength EN ISO – 179-2 Shall not be 20KJ/m2 4 Flexural Modulus Elasticity EN ISO – 178 Shall not be 2200 N/mm2 5 Mean Breaking Stress for welded corner (a) For the tensile bending test EN – 514 Shall not be 25 N/mm2 (b) For the compression bending test Shall not be 30N/mm2 6 Heat Reversion Test IS:4985-2000 Shall not be 2.0 % 7 Surface Spread of flame BS : 476 - Part 7 Classification 1 8 Ignitability Evaluation BS : 476 - Part 5 'P' Not easily ignitable 9 Tensile modulus ASTM D 638 Shall not be 35 MPa 10 Shear Modulus ASTM D 732 Shall not be 220 MPa 11 Tensile Strength EN ISO 527 Shall not be 30 MPa. All corners of frame shall be fusion welded. Both vertical sides of the frame, adjustable louver mechanism having one lever or fixed louver bracket shall be fitted with the of 4 mm Frosted Annealed glass. Window will be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge. uPVC Window and Door Profiles are warranted for a period of ten (10) years against non- uniform discoloration,wrapping and rotting under general use. a.Louver Window (Big Series) frame of size 67 x 62 mm & Mullion (if required) of size 67 x 78 mm. Fourth Floor

9.18

-

-

... More
Providing and fixing of factory made uPVC Sliding window (White Colour) with 3 Track with Mesh-2 Glass Sash + 1 Mesh Sash (Each sash shall be half of width of window) (Big Series) Window frame of size 122 x 54 mm & Sash of size 64 x 47 mm., comprising uPVC multi-chambered frame having in-built uPVC roller track on top and uPVC sash with wall thickness of 2.3mm (+-0.2 mm), duly reinforced with G.I. section 1.5 mm, wherever required. uPVC window & door profile shall be made in India & shall conform to BS EN 12608 and other standards as mentioned below: S.No. Name of the test Test Method Specified Parameter 1 Tensile Impact Strength ISO 8256 - more than 700Kj/m2 2 Vicat Softening Temperature EN ISO – 306 Shall not be 750C 3 Charpy Impact Strength EN ISO – 179-2 Shall not be 20KJ/m2 4 Flexural Modulus Elasticity EN ISO – 178 Shall not be 2200 N/mm2 5 Mean Breaking Stress for welded corner (a) For the tensile bending test EN – 514 Shall not be 25 N/mm2 (b) For the compression bending test Shall not be 30N/mm2 6 Heat Reversion Test IS:4985-2000 Shall not be 2.0 % 7 Surface Spread of flame BS : 476 - Part 7 Classification 1 8 Ignitability Evaluation BS : 476 - Part 5 'P' Not easily ignitable 9 Tensile modulus ASTM D 638 Shall not be 35 MPa 10 Shear Modulus ASTM D 732 Shall not be 220 MPa 11 Tensile Strength EN ISO 527 Shall not be 30 MPa All corners of frame and sash will be fusion welded. After placing 5 mm Float Annealed glass in the sash, uPVC glazing bead, interlock, EPDM / TPE gasket, brush shall be provided including touch lock and rollers & proper drainage system shall be provided. Window / Door will be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge. uPVC Window and Door Profiles are warranted for a period of ten (10) years against non-uniform discoloration, wrapping and rotting under general use. Ground Floor

57.6

-

-

... More
Providing and fixing of factory made uPVC Sliding window (White Colour) with 3 Track with Mesh-2 Glass Sash + 1 Mesh Sash (Each sash shall be half of width of window) (Big Series) Window frame of size 122 x 54 mm & Sash of size 64 x 47 mm., comprising uPVC multi-chambered frame having in-built uPVC roller track on top and uPVC sash with wall thickness of 2.3mm (+-0.2 mm), duly reinforced with G.I. section 1.5 mm, wherever required. uPVC window & door profile shall be made in India & shall conform to BS EN 12608 and other standards as mentioned below: S.No. Name of the test Test Method Specified Parameter 1 Tensile Impact Strength ISO 8256 - more than 700Kj/m2 2 Vicat Softening Temperature EN ISO – 306 Shall not be 750C 3 Charpy Impact Strength EN ISO – 179-2 Shall not be 20KJ/m2 4 Flexural Modulus Elasticity EN ISO – 178 Shall not be 2200 N/mm2 5 Mean Breaking Stress for welded corner (a) For the tensile bending test EN – 514 Shall not be 25 N/mm2 (b) For the compression bending test Shall not be 30N/mm2 6 Heat Reversion Test IS:4985-2000 Shall not be 2.0 % 7 Surface Spread of flame BS : 476 - Part 7 Classification 1 8 Ignitability Evaluation BS : 476 - Part 5 'P' Not easily ignitable 9 Tensile modulus ASTM D 638 Shall not be 35 MPa 10 Shear Modulus ASTM D 732 Shall not be 220 MPa 11 Tensile Strength EN ISO 527 Shall not be 30 MPa All corners of frame and sash will be fusion welded. After placing 5 mm Float Annealed glass in the sash, uPVC glazing bead, interlock, EPDM / TPE gasket, brush shall be provided including touch lock and rollers & proper drainage system shall be provided. Window / Door will be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge. uPVC Window and Door Profiles are warranted for a period of ten (10) years against non-uniform discoloration, wrapping and rotting under general use. First Floor

57.6

-

-

... More
Providing and fixing of factory made uPVC Sliding window (White Colour) with 3 Track with Mesh-2 Glass Sash + 1 Mesh Sash (Each sash shall be half of width of window) (Big Series) Window frame of size 122 x 54 mm & Sash of size 64 x 47 mm., comprising uPVC multi-chambered frame having in-built uPVC roller track on top and uPVC sash with wall thickness of 2.3mm (+-0.2 mm), duly reinforced with G.I. section 1.5 mm, wherever required. uPVC window & door profile shall be made in India & shall conform to BS EN 12608 and other standards as mentioned below: S.No. Name of the test Test Method Specified Parameter 1 Tensile Impact Strength ISO 8256 - more than 700Kj/m2 2 Vicat Softening Temperature EN ISO – 306 Shall not be 750C 3 Charpy Impact Strength EN ISO – 179-2 Shall not be 20KJ/m2 4 Flexural Modulus Elasticity EN ISO – 178 Shall not be 2200 N/mm2 5 Mean Breaking Stress for welded corner (a) For the tensile bending test EN – 514 Shall not be 25 N/mm2 (b) For the compression bending test Shall not be 30N/mm2 6 Heat Reversion Test IS:4985-2000 Shall not be 2.0 % 7 Surface Spread of flame BS : 476 - Part 7 Classification 1 8 Ignitability Evaluation BS : 476 - Part 5 'P' Not easily ignitable 9 Tensile modulus ASTM D 638 Shall not be 35 MPa 10 Shear Modulus ASTM D 732 Shall not be 220 MPa 11 Tensile Strength EN ISO 527 Shall not be 30 MPa All corners of frame and sash will be fusion welded. After placing 5 mm Float Annealed glass in the sash, uPVC glazing bead, interlock, EPDM / TPE gasket, brush shall be provided including touch lock and rollers & proper drainage system shall be provided. Window / Door will be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge. uPVC Window and Door Profiles are warranted for a period of ten (10) years against non-uniform discoloration, wrapping and rotting under general use. Second Floor

57.6

-

-

... More
Providing and fixing of factory made uPVC Sliding window (White Colour) with 3 Track with Mesh-2 Glass Sash + 1 Mesh Sash (Each sash shall be half of width of window) (Big Series) Window frame of size 122 x 54 mm & Sash of size 64 x 47 mm., comprising uPVC multi-chambered frame having in-built uPVC roller track on top and uPVC sash with wall thickness of 2.3mm (+-0.2 mm), duly reinforced with G.I. section 1.5 mm, wherever required. uPVC window & door profile shall be made in India & shall conform to BS EN 12608 and other standards as mentioned below: S.No. Name of the test Test Method Specified Parameter 1 Tensile Impact Strength ISO 8256 - more than 700Kj/m2 2 Vicat Softening Temperature EN ISO – 306 Shall not be 750C 3 Charpy Impact Strength EN ISO – 179-2 Shall not be 20KJ/m2 4 Flexural Modulus Elasticity EN ISO – 178 Shall not be 2200 N/mm2 5 Mean Breaking Stress for welded corner (a) For the tensile bending test EN – 514 Shall not be 25 N/mm2 (b) For the compression bending test Shall not be 30N/mm2 6 Heat Reversion Test IS:4985-2000 Shall not be 2.0 % 7 Surface Spread of flame BS : 476 - Part 7 Classification 1 8 Ignitability Evaluation BS : 476 - Part 5 'P' Not easily ignitable 9 Tensile modulus ASTM D 638 Shall not be 35 MPa 10 Shear Modulus ASTM D 732 Shall not be 220 MPa 11 Tensile Strength EN ISO 527 Shall not be 30 MPa All corners of frame and sash will be fusion welded. After placing 5 mm Float Annealed glass in the sash, uPVC glazing bead, interlock, EPDM / TPE gasket, brush shall be provided including touch lock and rollers & proper drainage system shall be provided. Window / Door will be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge. uPVC Window and Door Profiles are warranted for a period of ten (10) years against non-uniform discoloration, wrapping and rotting under general use. Third Floor

41.4

-

-

... More
Providing and fixing of factory made uPVC Sliding window (White Colour) with 3 Track with Mesh-2 Glass Sash + 1 Mesh Sash (Each sash shall be half of width of window) (Big Series) Window frame of size 122 x 54 mm & Sash of size 64 x 47 mm., comprising uPVC multi-chambered frame having in-built uPVC roller track on top and uPVC sash with wall thickness of 2.3mm (+-0.2 mm), duly reinforced with G.I. section 1.5 mm, wherever required. uPVC window & door profile shall be made in India & shall conform to BS EN 12608 and other standards as mentioned below: S.No. Name of the test Test Method Specified Parameter 1 Tensile Impact Strength ISO 8256 - more than 700Kj/m2 2 Vicat Softening Temperature EN ISO – 306 Shall not be 750C 3 Charpy Impact Strength EN ISO – 179-2 Shall not be 20KJ/m2 4 Flexural Modulus Elasticity EN ISO – 178 Shall not be 2200 N/mm2 5 Mean Breaking Stress for welded corner (a) For the tensile bending test EN – 514 Shall not be 25 N/mm2 (b) For the compression bending test Shall not be 30N/mm2 6 Heat Reversion Test IS:4985-2000 Shall not be 2.0 % 7 Surface Spread of flame BS : 476 - Part 7 Classification 1 8 Ignitability Evaluation BS : 476 - Part 5 'P' Not easily ignitable 9 Tensile modulus ASTM D 638 Shall not be 35 MPa 10 Shear Modulus ASTM D 732 Shall not be 220 MPa 11 Tensile Strength EN ISO 527 Shall not be 30 MPa All corners of frame and sash will be fusion welded. After placing 5 mm Float Annealed glass in the sash, uPVC glazing bead, interlock, EPDM / TPE gasket, brush shall be provided including touch lock and rollers & proper drainage system shall be provided. Window / Door will be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge. uPVC Window and Door Profiles are warranted for a period of ten (10) years against non-uniform discoloration, wrapping and rotting under general use. Fourth Floor

54

-

-

... More
Providing and fixing mild steel grill work for windows, ventilators 20 kilogram per square metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. Ground Floor

73.53

-

-

... More
Providing and fixing mild steel grill work for windows, ventilators 20 kilogram per square metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. First Floor

69.48

-

-

... More
Providing and fixing mild steel grill work for windows, ventilators 20 kilogram per square metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. Second Floor

66.78

-

-

... More
Providing and fixing mild steel grill work for windows, ventilators 20 kilogram per square metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. Third Floor

49.5

-

-

... More
Providing and fixing mild steel grill work for windows, ventilators 20 kilogram per square metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. Fourth Floor

63.18

-

-

... More
Providing and fixing in position, Single shuttered aluminium extruded powder coated openable door of overall size 0.90 metre x 2.40 metre with aluminium door frame of powder coated section 101.60 x 44.75 milimetre, 3.18 milimetre thick and shutter comprising of powder coated section having bottom and lock rail of size 150 milimetre x 44.5 milimetre x 3.00 milimetre thick top rails 47.62 x 44.45 milimetre x 3.00 milimetre thick, vertical style 47.62 x 44.45 milimetre, 3.00 milimetre thick and for shutter plain glass panes 5 milimetre thick for top panels and 12 milimetre thick both side laminated phenol bonded particle board panels for bottom panels etc., Indian Standard Institute mark, with bijagiri having heavy duty concealed lock, necessary beading, glazing clips, Poly Venyl Chloride gaskets, 250 milimetre length tower bolts, 150 milimetre diameter pad handle, etc. as per detailed design and drawing or as directed by engineer in charge including all materials, labours and equipment etc. complete. Ground Floor

28.8

-

-

... More
Providing and fixing in position, Single shuttered aluminium extruded powder coated openable door of overall size 0.90 metre x 2.40 metre with aluminium door frame of powder coated section 101.60 x 44.75 milimetre, 3.18 milimetre thick and shutter comprising of powder coated section having bottom and lock rail of size 150 milimetre x 44.5 milimetre x 3.00 milimetre thick top rails 47.62 x 44.45 milimetre x 3.00 milimetre thick, vertical style 47.62 x 44.45 milimetre, 3.00 milimetre thick and for shutter plain glass panes 5 milimetre thick for top panels and 12 milimetre thick both side laminated phenol bonded particle board panels for bottom panels etc., Indian Standard Institute mark, with bijagiri having heavy duty concealed lock, necessary beading, glazing clips, Poly Venyl Chloride gaskets, 250 milimetre length tower bolts, 150 milimetre diameter pad handle, etc. as per detailed design and drawing or as directed by engineer in charge including all materials, labours and equipment etc. complete. First Floor

28.8

-

-

... More
Providing and fixing in position, Single shuttered aluminium extruded powder coated openable door of overall size 0.90 metre x 2.40 metre with aluminium door frame of powder coated section 101.60 x 44.75 milimetre, 3.18 milimetre thick and shutter comprising of powder coated section having bottom and lock rail of size 150 milimetre x 44.5 milimetre x 3.00 milimetre thick top rails 47.62 x 44.45 milimetre x 3.00 milimetre thick, vertical style 47.62 x 44.45 milimetre, 3.00 milimetre thick and for shutter plain glass panes 5 milimetre thick for top panels and 12 milimetre thick both side laminated phenol bonded particle board panels for bottom panels etc., Indian Standard Institute mark, with bijagiri having heavy duty concealed lock, necessary beading, glazing clips, Poly Venyl Chloride gaskets, 250 milimetre length tower bolts, 150 milimetre diameter pad handle, etc. as per detailed design and drawing or as directed by engineer in charge including all materials, labours and equipment etc. complete. Second Floor

28.8

-

-

... More
Providing and fixing in position, Single shuttered aluminium extruded powder coated openable door of overall size 0.90 metre x 2.40 metre with aluminium door frame of powder coated section 101.60 x 44.75 milimetre, 3.18 milimetre thick and shutter comprising of powder coated section having bottom and lock rail of size 150 milimetre x 44.5 milimetre x 3.00 milimetre thick top rails 47.62 x 44.45 milimetre x 3.00 milimetre thick, vertical style 47.62 x 44.45 milimetre, 3.00 milimetre thick and for shutter plain glass panes 5 milimetre thick for top panels and 12 milimetre thick both side laminated phenol bonded particle board panels for bottom panels etc., Indian Standard Institute mark, with bijagiri having heavy duty concealed lock, necessary beading, glazing clips, Poly Venyl Chloride gaskets, 250 milimetre length tower bolts, 150 milimetre diameter pad handle, etc. as per detailed design and drawing or as directed by engineer in charge including all materials, labours and equipment etc. complete. Third Floor

28.8

-

-

... More
Providing and fixing in position, Single shuttered aluminium extruded powder coated openable door of overall size 0.90 metre x 2.40 metre with aluminium door frame of powder coated section 101.60 x 44.75 milimetre, 3.18 milimetre thick and shutter comprising of powder coated section having bottom and lock rail of size 150 milimetre x 44.5 milimetre x 3.00 milimetre thick top rails 47.62 x 44.45 milimetre x 3.00 milimetre thick, vertical style 47.62 x 44.45 milimetre, 3.00 milimetre thick and for shutter plain glass panes 5 milimetre thick for top panels and 12 milimetre thick both side laminated phenol bonded particle board panels for bottom panels etc., Indian Standard Institute mark, with bijagiri having heavy duty concealed lock, necessary beading, glazing clips, Poly Venyl Chloride gaskets, 250 milimetre length tower bolts, 150 milimetre diameter pad handle, etc. as per detailed design and drawing or as directed by engineer in charge including all materials, labours and equipment etc. complete. Fourth Floor

28.8

-

-

... More
Providing and fixing collapsible steel gate in one/ two leaves with hot rolled vertical channels of 18 x 9 x 3 milimetre minimum size, crossings of mild steel flats of size 18 x 5 milimetre T or E section for runner of minimum 40 x 6 milimetre size for flange, mild steel flat for top runner of minimum size 40 x 12 milimetre with roller wheels confirming to grade F.G. 150 fitted with snap headed rivets of minimum size 6 milimetre max. spacing of vertical channels be 100 milimetre enclosed gate position and clear space of 150 milimetre between two sets of crossings with hold fasts, stoppers, spaces, handles, locking arrangement and one coat of red lead primer & oil painting etc. complete. (I.S. 10521-1983). Ground Floor

36

-

-

... More
Providing and fixing collapsible steel gate in one/ two leaves with hot rolled vertical channels of 18 x 9 x 3 milimetre minimum size, crossings of mild steel flats of size 18 x 5 milimetre T or E section for runner of minimum 40 x 6 milimetre size for flange, mild steel flat for top runner of minimum size 40 x 12 milimetre with roller wheels confirming to grade F.G. 150 fitted with snap headed rivets of minimum size 6 milimetre max. spacing of vertical channels be 100 milimetre enclosed gate position and clear space of 150 milimetre between two sets of crossings with hold fasts, stoppers, spaces, handles, locking arrangement and one coat of red lead primer & oil painting etc. complete. (I.S. 10521-1983). First Floor

9

-

-

... More
Providing and fixing collapsible steel gate in one/ two leaves with hot rolled vertical channels of 18 x 9 x 3 milimetre minimum size, crossings of mild steel flats of size 18 x 5 milimetre T or E section for runner of minimum 40 x 6 milimetre size for flange, mild steel flat for top runner of minimum size 40 x 12 milimetre with roller wheels confirming to grade F.G. 150 fitted with snap headed rivets of minimum size 6 milimetre max. spacing of vertical channels be 100 milimetre enclosed gate position and clear space of 150 milimetre between two sets of crossings with hold fasts, stoppers, spaces, handles, locking arrangement and one coat of red lead primer & oil painting etc. complete. (I.S. 10521-1983). Second Floor

9

-

-

... More
Providing and fixing collapsible steel gate in one/ two leaves with hot rolled vertical channels of 18 x 9 x 3 milimetre minimum size, crossings of mild steel flats of size 18 x 5 milimetre T or E section for runner of minimum 40 x 6 milimetre size for flange, mild steel flat for top runner of minimum size 40 x 12 milimetre with roller wheels confirming to grade F.G. 150 fitted with snap headed rivets of minimum size 6 milimetre max. spacing of vertical channels be 100 milimetre enclosed gate position and clear space of 150 milimetre between two sets of crossings with hold fasts, stoppers, spaces, handles, locking arrangement and one coat of red lead primer & oil painting etc. complete. (I.S. 10521-1983). Third Floor

9

-

-

... More
Providing and fixing collapsible steel gate in one/ two leaves with hot rolled vertical channels of 18 x 9 x 3 milimetre minimum size, crossings of mild steel flats of size 18 x 5 milimetre T or E section for runner of minimum 40 x 6 milimetre size for flange, mild steel flat for top runner of minimum size 40 x 12 milimetre with roller wheels confirming to grade F.G. 150 fitted with snap headed rivets of minimum size 6 milimetre max. spacing of vertical channels be 100 milimetre enclosed gate position and clear space of 150 milimetre between two sets of crossings with hold fasts, stoppers, spaces, handles, locking arrangement and one coat of red lead primer & oil painting etc. complete. (I.S. 10521-1983). Fourth Floor

9

-

-

... More
Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 milimetre with lock plate of 3.15 milimetre thickness reinforced with 35 x 35 x 5 milimetre angle section fitted with sliding bolts and handles for both sides, deep Mild Steel channel section of depth and thickness not less than 65 milimetre and 3.15 milimetre respectively with hold fast arrangments, Mild Steel Bracket plate 300 x 300 x 3.15 milimetre minimum size and shape with square bar suspension shaft of minimum 32 milimetre diameter, hood cover of Mild Steel sheet not less than 0.9 milimetre thickness and of any size at top and safety devices including mechanical gear operation arrangementconsisting of worm gear whwwls and worms of high grade cast iron or mild steel and one coat of red lead primer complete. (I. S. 6248 - 1979) with mechanical gear. Ground Floor

10.8

-

-

... More
Providing and fixing country cut teak wood single leaf pannelled door shutter without fanlight 35 milimetre thick as per drawing consisting of teak wood top rail size 100 milimetre x 35 milimetre and bottom rail and lock rail 200 milimetre x 35 milimetre insert pannel 12 milimetre thick commercial ply faced teak wood particle board with phenol formaldehyde synthetic resin (Generally conforming to Indian Standard 3097) excluding frame, including stainless steel fixtures and fastening and fastening and teak wood beading to junctions of pannelled inserts and as instructed by Engineer in charge including three coats of oil painting etc. complete. Ground Floor

48.18

-

-

... More
Providing and fixing country cut teak wood single leaf pannelled door shutter without fanlight 35 milimetre thick as per drawing consisting of teak wood top rail size 100 milimetre x 35 milimetre and bottom rail and lock rail 200 milimetre x 35 milimetre insert pannel 12 milimetre thick commercial ply faced teak wood particle board with phenol formaldehyde synthetic resin (Generally conforming to Indian Standard 3097) excluding frame, including stainless steel fixtures and fastening and fastening and teak wood beading to junctions of pannelled inserts and as instructed by Engineer in charge including three coats of oil painting etc. complete. First Floor

90.72

-

-

... More
Providing and fixing country cut teak wood single leaf pannelled door shutter without fanlight 35 milimetre thick as per drawing consisting of teak wood top rail size 100 milimetre x 35 milimetre and bottom rail and lock rail 200 milimetre x 35 milimetre insert pannel 12 milimetre thick commercial ply faced teak wood particle board with phenol formaldehyde synthetic resin (Generally conforming to Indian Standard 3097) excluding frame, including stainless steel fixtures and fastening and fastening and teak wood beading to junctions of pannelled inserts and as instructed by Engineer in charge including three coats of oil painting etc. complete. Second Floor

65.52

-

-

... More
Providing and fixing country cut teak wood single leaf pannelled door shutter without fanlight 35 milimetre thick as per drawing consisting of teak wood top rail size 100 milimetre x 35 milimetre and bottom rail and lock rail 200 milimetre x 35 milimetre insert pannel 12 milimetre thick commercial ply faced teak wood particle board with phenol formaldehyde synthetic resin (Generally conforming to Indian Standard 3097) excluding frame, including stainless steel fixtures and fastening and fastening and teak wood beading to junctions of pannelled inserts and as instructed by Engineer in charge including three coats of oil painting etc. complete. Third Floor

105.84

-

-

... More
Providing and fixing country cut teak wood single leaf pannelled door shutter without fanlight 35 milimetre thick as per drawing consisting of teak wood top rail size 100 milimetre x 35 milimetre and bottom rail and lock rail 200 milimetre x 35 milimetre insert pannel 12 milimetre thick commercial ply faced teak wood particle board with phenol formaldehyde synthetic resin (Generally conforming to Indian Standard 3097) excluding frame, including stainless steel fixtures and fastening and fastening and teak wood beading to junctions of pannelled inserts and as instructed by Engineer in charge including three coats of oil painting etc. complete. Fourth Floor

47.88

-

-

... More
Providing and fixing the country cut teak wood double or single leaf second class fully pannelled door shutter with 35 milimetre thick style and rail with 25 milimetre thick pannels with openable fan light as per detailed drawings. Excluding the door frame 60 milimetre x 100 milimetre, including stainless steel fixtures and fastening and finishing the wood work with oil panting 3 coats. Ground Floor

141.09

-

-

... More
Providing and fixing the country cut teak wood double or single leaf second class fully pannelled door shutter with 35 milimetre thick style and rail with 25 milimetre thick pannels with openable fan light as per detailed drawings. Excluding the door frame 60 milimetre x 100 milimetre, including stainless steel fixtures and fastening and finishing the wood work with oil panting 3 coats. First Floor

74.06

-

-

... More
Providing and fixing the country cut teak wood double or single leaf second class fully pannelled door shutter with 35 milimetre thick style and rail with 25 milimetre thick pannels with openable fan light as per detailed drawings. Excluding the door frame 60 milimetre x 100 milimetre, including stainless steel fixtures and fastening and finishing the wood work with oil panting 3 coats. Second Floor

47.52

-

-

... More
Providing and fixing the country cut teak wood double or single leaf second class fully pannelled door shutter with 35 milimetre thick style and rail with 25 milimetre thick pannels with openable fan light as per detailed drawings. Excluding the door frame 60 milimetre x 100 milimetre, including stainless steel fixtures and fastening and finishing the wood work with oil panting 3 coats. Third Floor

75.6

-

-

... More
Providing and fixing the country cut teak wood double or single leaf second class fully pannelled door shutter with 35 milimetre thick style and rail with 25 milimetre thick pannels with openable fan light as per detailed drawings. Excluding the door frame 60 milimetre x 100 milimetre, including stainless steel fixtures and fastening and finishing the wood work with oil panting 3 coats. Fourth Floor

77.76

-

-

... More
Providing and Fixing 30 milimetre thick both side Prelaminated Solid Panel Poly Venyl Chloride Door Shutter consisting of frame made out of Mild Steel tubes of 19 guage thickness and, size 19 x 19 milimetre for styles and 15 x15 milimetre for the top and bottom rails, Mild Steel frame shall have a coat of metel primer of approved make and manufacture. Mild Steel frame shall be covered with heat mouled Poly Venyl Chloride ' C ' channel made from 5 milimetre (+/- 0.25) thick prelaminated sheet of density 600 kilogram per cubic metre, of size 30 milimetre thickness 70 milimetre width out of which 50 milimetre shall be flat and 20 milimetre shall be tapered in 45 degree angle on either side forming stiles and 5 milimetre thick, 95 milimetre wide Poly Venyl Chloride sheet out of which 75 milimetre shall be falt and 20 milimetre shall be tapered in 45 degree angle on the inner side to form top and bottom rail and 115 milimetre wide Poly Venyl Chloride sheet out of which 75 milimetre shall be falt and 20 milimetre shall be tapered on both sides to form lock rail.Top,bottom and lock rail shall be provided either side of the panel. An additional 5 milimetre (+/- 0.25) thick Poly Venyl Chloride strip of 20 milimetre width is to be stuck on the bottom side of the ' c ' channel prelaminated paneling of 5 milimetre (+/- 0.25) thick Poly Venyl Chloride sheet to be fitted inside the mild steel frame welded/ sealed to the styles and rails with 5 milimetre (+/- 0.25) x 30 milimetre Poly Venyl Chloride sheet beading on either side and joined together with solvent cement adhesive etc ,10 milimetre thickness (5 milimetre (+/- 0.25) x 2 nos ) 20 milimetre wide cross Poly Venyl Chloride sheet as gap insert for the rail and bottom rail. Door to be fixed to frames with 3 nos mild steel powder coated but hinges of size 100 milimetre x 25 milimetre x 2 milimetre using 32 milimetre long steel screws drilled suitable to pass through both the walls of the Mild Steel tube. Other hardwares should be fixed with 19 x 6 milimetre size steel screws including fixture fasting complete as per direction of engineer -in -charge. Ground Floor

32.85

-

-

... More
Providing and Fixing 30 milimetre thick both side Prelaminated Solid Panel Poly Venyl Chloride Door Shutter consisting of frame made out of Mild Steel tubes of 19 guage thickness and, size 19 x 19 milimetre for styles and 15 x15 milimetre for the top and bottom rails, Mild Steel frame shall have a coat of metel primer of approved make and manufacture. Mild Steel frame shall be covered with heat mouled Poly Venyl Chloride ' C ' channel made from 5 milimetre (+/- 0.25) thick prelaminated sheet of density 600 kilogram per cubic metre, of size 30 milimetre thickness 70 milimetre width out of which 50 milimetre shall be flat and 20 milimetre shall be tapered in 45 degree angle on either side forming stiles and 5 milimetre thick, 95 milimetre wide Poly Venyl Chloride sheet out of which 75 milimetre shall be falt and 20 milimetre shall be tapered in 45 degree angle on the inner side to form top and bottom rail and 115 milimetre wide Poly Venyl Chloride sheet out of which 75 milimetre shall be falt and 20 milimetre shall be tapered on both sides to form lock rail.Top,bottom and lock rail shall be provided either side of the panel. An additional 5 milimetre (+/- 0.25) thick Poly Venyl Chloride strip of 20 milimetre width is to be stuck on the bottom side of the ' c ' channel prelaminated paneling of 5 milimetre (+/- 0.25) thick Poly Venyl Chloride sheet to be fitted inside the mild steel frame welded/ sealed to the styles and rails with 5 milimetre (+/- 0.25) x 30 milimetre Poly Venyl Chloride sheet beading on either side and joined together with solvent cement adhesive etc ,10 milimetre thickness (5 milimetre (+/- 0.25) x 2 nos ) 20 milimetre wide cross Poly Venyl Chloride sheet as gap insert for the rail and bottom rail. Door to be fixed to frames with 3 nos mild steel powder coated but hinges of size 100 milimetre x 25 milimetre x 2 milimetre using 32 milimetre long steel screws drilled suitable to pass through both the walls of the Mild Steel tube. Other hardwares should be fixed with 19 x 6 milimetre size steel screws including fixture fasting complete as per direction of engineer -in -charge. First Floor

34.31

-

-

... More
Providing and Fixing 30 milimetre thick both side Prelaminated Solid Panel Poly Venyl Chloride Door Shutter consisting of frame made out of Mild Steel tubes of 19 guage thickness and, size 19 x 19 milimetre for styles and 15 x15 milimetre for the top and bottom rails, Mild Steel frame shall have a coat of metel primer of approved make and manufacture. Mild Steel frame shall be covered with heat mouled Poly Venyl Chloride ' C ' channel made from 5 milimetre (+/- 0.25) thick prelaminated sheet of density 600 kilogram per cubic metre, of size 30 milimetre thickness 70 milimetre width out of which 50 milimetre shall be flat and 20 milimetre shall be tapered in 45 degree angle on either side forming stiles and 5 milimetre thick, 95 milimetre wide Poly Venyl Chloride sheet out of which 75 milimetre shall be falt and 20 milimetre shall be tapered in 45 degree angle on the inner side to form top and bottom rail and 115 milimetre wide Poly Venyl Chloride sheet out of which 75 milimetre shall be falt and 20 milimetre shall be tapered on both sides to form lock rail.Top,bottom and lock rail shall be provided either side of the panel. An additional 5 milimetre (+/- 0.25) thick Poly Venyl Chloride strip of 20 milimetre width is to be stuck on the bottom side of the ' c ' channel prelaminated paneling of 5 milimetre (+/- 0.25) thick Poly Venyl Chloride sheet to be fitted inside the mild steel frame welded/ sealed to the styles and rails with 5 milimetre (+/- 0.25) x 30 milimetre Poly Venyl Chloride sheet beading on either side and joined together with solvent cement adhesive etc ,10 milimetre thickness (5 milimetre (+/- 0.25) x 2 nos ) 20 milimetre wide cross Poly Venyl Chloride sheet as gap insert for the rail and bottom rail. Door to be fixed to frames with 3 nos mild steel powder coated but hinges of size 100 milimetre x 25 milimetre x 2 milimetre using 32 milimetre long steel screws drilled suitable to pass through both the walls of the Mild Steel tube. Other hardwares should be fixed with 19 x 6 milimetre size steel screws including fixture fasting complete as per direction of engineer -in -charge. Second Floor

16.61

-

-

... More
Providing and Fixing 30 milimetre thick both side Prelaminated Solid Panel Poly Venyl Chloride Door Shutter consisting of frame made out of Mild Steel tubes of 19 guage thickness and, size 19 x 19 milimetre for styles and 15 x15 milimetre for the top and bottom rails, Mild Steel frame shall have a coat of metel primer of approved make and manufacture. Mild Steel frame shall be covered with heat mouled Poly Venyl Chloride ' C ' channel made from 5 milimetre (+/- 0.25) thick prelaminated sheet of density 600 kilogram per cubic metre, of size 30 milimetre thickness 70 milimetre width out of which 50 milimetre shall be flat and 20 milimetre shall be tapered in 45 degree angle on either side forming stiles and 5 milimetre thick, 95 milimetre wide Poly Venyl Chloride sheet out of which 75 milimetre shall be falt and 20 milimetre shall be tapered in 45 degree angle on the inner side to form top and bottom rail and 115 milimetre wide Poly Venyl Chloride sheet out of which 75 milimetre shall be falt and 20 milimetre shall be tapered on both sides to form lock rail.Top,bottom and lock rail shall be provided either side of the panel. An additional 5 milimetre (+/- 0.25) thick Poly Venyl Chloride strip of 20 milimetre width is to be stuck on the bottom side of the ' c ' channel prelaminated paneling of 5 milimetre (+/- 0.25) thick Poly Venyl Chloride sheet to be fitted inside the mild steel frame welded/ sealed to the styles and rails with 5 milimetre (+/- 0.25) x 30 milimetre Poly Venyl Chloride sheet beading on either side and joined together with solvent cement adhesive etc ,10 milimetre thickness (5 milimetre (+/- 0.25) x 2 nos ) 20 milimetre wide cross Poly Venyl Chloride sheet as gap insert for the rail and bottom rail. Door to be fixed to frames with 3 nos mild steel powder coated but hinges of size 100 milimetre x 25 milimetre x 2 milimetre using 32 milimetre long steel screws drilled suitable to pass through both the walls of the Mild Steel tube. Other hardwares should be fixed with 19 x 6 milimetre size steel screws including fixture fasting complete as per direction of engineer -in -charge. Third Floor

22.61

-

-

... More
Providing and Fixing 30 milimetre thick both side Prelaminated Solid Panel Poly Venyl Chloride Door Shutter consisting of frame made out of Mild Steel tubes of 19 guage thickness and, size 19 x 19 milimetre for styles and 15 x15 milimetre for the top and bottom rails, Mild Steel frame shall have a coat of metel primer of approved make and manufacture. Mild Steel frame shall be covered with heat mouled Poly Venyl Chloride ' C ' channel made from 5 milimetre (+/- 0.25) thick prelaminated sheet of density 600 kilogram per cubic metre, of size 30 milimetre thickness 70 milimetre width out of which 50 milimetre shall be flat and 20 milimetre shall be tapered in 45 degree angle on either side forming stiles and 5 milimetre thick, 95 milimetre wide Poly Venyl Chloride sheet out of which 75 milimetre shall be falt and 20 milimetre shall be tapered in 45 degree angle on the inner side to form top and bottom rail and 115 milimetre wide Poly Venyl Chloride sheet out of which 75 milimetre shall be falt and 20 milimetre shall be tapered on both sides to form lock rail.Top,bottom and lock rail shall be provided either side of the panel. An additional 5 milimetre (+/- 0.25) thick Poly Venyl Chloride strip of 20 milimetre width is to be stuck on the bottom side of the ' c ' channel prelaminated paneling of 5 milimetre (+/- 0.25) thick Poly Venyl Chloride sheet to be fitted inside the mild steel frame welded/ sealed to the styles and rails with 5 milimetre (+/- 0.25) x 30 milimetre Poly Venyl Chloride sheet beading on either side and joined together with solvent cement adhesive etc ,10 milimetre thickness (5 milimetre (+/- 0.25) x 2 nos ) 20 milimetre wide cross Poly Venyl Chloride sheet as gap insert for the rail and bottom rail. Door to be fixed to frames with 3 nos mild steel powder coated but hinges of size 100 milimetre x 25 milimetre x 2 milimetre using 32 milimetre long steel screws drilled suitable to pass through both the walls of the Mild Steel tube. Other hardwares should be fixed with 19 x 6 milimetre size steel screws including fixture fasting complete as per direction of engineer -in -charge. Fourth Floor

31.73

-

-

... More
Supply and installation of CEILING HUNG cubicles of width and depth as per specifications/ site drawings. Cubicle height to be 2400 mm. Std Sizes (W x D x H): 900 mm x 1550 mm x 2400 mm, (Height is including 100 mm gap from bottom) Door Width- 600 mm ITEM DESCRIPTION Made from solid grade Merino make compact high pressure laminate as per IS:2046 and EN 438 manufactured under high specific pressure 5 MPa and temperature 120° C, All doors will be of single colour and made of 18 mm thick Merino HPL compact panel. The doors will have chamfered edges. Each door will be supported by 3 stainless steel made hinges affixed to the pilasters. All intermediate partitions or dividers will be made of 12 mm thick Merino HPL compact laminate panels. Size of panels to be as per drawing. HARDWARE & ACCESSORIES are H shaped (Top) head frame structure made of extruded Aluminum grade 6063 T5-50 micron epoxy powder coated for surface protection. Size to be 125x70x5T. Corner joinery section, Size to be 40x16.5x1.8T. U-Channel Wall joinery section, Size to be 22x16x1.6T. Door stopper section, Size to be 21x12.5x1.6T. Spring loaded Butt Hinges made from Stainless steel grade 304. Surface finish to be matt type. Covers to be lacor coated.Coat hook with rubber stopper made from Stainless steel grade 304. Surface finish to be matt type. etc complete. Ground Floor

77.7

-

-

... More
Supply and installation of CEILING HUNG cubicles of width and depth as per specifications/ site drawings. Cubicle height to be 2400 mm. Std Sizes (W x D x H): 900 mm x 1550 mm x 2400 mm, (Height is including 100 mm gap from bottom) Door Width- 600 mm ITEM DESCRIPTION Made from solid grade Merino make compact high pressure laminate as per IS:2046 and EN 438 manufactured under high specific pressure 5 MPa and temperature 120° C, All doors will be of single colour and made of 18 mm thick Merino HPL compact panel. The doors will have chamfered edges. Each door will be supported by 3 stainless steel made hinges affixed to the pilasters. All intermediate partitions or dividers will be made of 12 mm thick Merino HPL compact laminate panels. Size of panels to be as per drawing. HARDWARE & ACCESSORIES are H shaped (Top) head frame structure made of extruded Aluminum grade 6063 T5-50 micron epoxy powder coated for surface protection. Size to be 125x70x5T. Corner joinery section, Size to be 40x16.5x1.8T. U-Channel Wall joinery section, Size to be 22x16x1.6T. Door stopper section, Size to be 21x12.5x1.6T. Spring loaded Butt Hinges made from Stainless steel grade 304. Surface finish to be matt type. Covers to be lacor coated.Coat hook with rubber stopper made from Stainless steel grade 304. Surface finish to be matt type. etc complete. First Floor

263.43

-

-

... More
Supply and installation of CEILING HUNG cubicles of width and depth as per specifications/ site drawings. Cubicle height to be 2400 mm. Std Sizes (W x D x H): 900 mm x 1550 mm x 2400 mm, (Height is including 100 mm gap from bottom) Door Width- 600 mm ITEM DESCRIPTION Made from solid grade Merino make compact high pressure laminate as per IS:2046 and EN 438 manufactured under high specific pressure 5 MPa and temperature 120° C, All doors will be of single colour and made of 18 mm thick Merino HPL compact panel. The doors will have chamfered edges. Each door will be supported by 3 stainless steel made hinges affixed to the pilasters. All intermediate partitions or dividers will be made of 12 mm thick Merino HPL compact laminate panels. Size of panels to be as per drawing. HARDWARE & ACCESSORIES are H shaped (Top) head frame structure made of extruded Aluminum grade 6063 T5-50 micron epoxy powder coated for surface protection. Size to be 125x70x5T. Corner joinery section, Size to be 40x16.5x1.8T. U-Channel Wall joinery section, Size to be 22x16x1.6T. Door stopper section, Size to be 21x12.5x1.6T. Spring loaded Butt Hinges made from Stainless steel grade 304. Surface finish to be matt type. Covers to be lacor coated.Coat hook with rubber stopper made from Stainless steel grade 304. Surface finish to be matt type. etc complete. Second Floor

180.15

-

-

... More
Supply and installation of CEILING HUNG cubicles of width and depth as per specifications/ site drawings. Cubicle height to be 2400 mm. Std Sizes (W x D x H): 900 mm x 1550 mm x 2400 mm, (Height is including 100 mm gap from bottom) Door Width- 600 mm ITEM DESCRIPTION Made from solid grade Merino make compact high pressure laminate as per IS:2046 and EN 438 manufactured under high specific pressure 5 MPa and temperature 120° C, All doors will be of single colour and made of 18 mm thick Merino HPL compact panel. The doors will have chamfered edges. Each door will be supported by 3 stainless steel made hinges affixed to the pilasters. All intermediate partitions or dividers will be made of 12 mm thick Merino HPL compact laminate panels. Size of panels to be as per drawing. HARDWARE & ACCESSORIES are H shaped (Top) head frame structure made of extruded Aluminum grade 6063 T5-50 micron epoxy powder coated for surface protection. Size to be 125x70x5T. Corner joinery section, Size to be 40x16.5x1.8T. U-Channel Wall joinery section, Size to be 22x16x1.6T. Door stopper section, Size to be 21x12.5x1.6T. Spring loaded Butt Hinges made from Stainless steel grade 304. Surface finish to be matt type. Covers to be lacor coated.Coat hook with rubber stopper made from Stainless steel grade 304. Surface finish to be matt type. etc complete. Third Floor

313.8

-

-

... More
Supply and installation of CEILING HUNG cubicles of width and depth as per specifications/ site drawings. Cubicle height to be 2400 mm. Std Sizes (W x D x H): 900 mm x 1550 mm x 2400 mm, (Height is including 100 mm gap from bottom) Door Width- 600 mm ITEM DESCRIPTION Made from solid grade Merino make compact high pressure laminate as per IS:2046 and EN 438 manufactured under high specific pressure 5 MPa and temperature 120° C, All doors will be of single colour and made of 18 mm thick Merino HPL compact panel. The doors will have chamfered edges. Each door will be supported by 3 stainless steel made hinges affixed to the pilasters. All intermediate partitions or dividers will be made of 12 mm thick Merino HPL compact laminate panels. Size of panels to be as per drawing. HARDWARE & ACCESSORIES are H shaped (Top) head frame structure made of extruded Aluminum grade 6063 T5-50 micron epoxy powder coated for surface protection. Size to be 125x70x5T. Corner joinery section, Size to be 40x16.5x1.8T. U-Channel Wall joinery section, Size to be 22x16x1.6T. Door stopper section, Size to be 21x12.5x1.6T. Spring loaded Butt Hinges made from Stainless steel grade 304. Surface finish to be matt type. Covers to be lacor coated.Coat hook with rubber stopper made from Stainless steel grade 304. Surface finish to be matt type. etc complete. Fourth Floor

119.7

-

-

... More
Providing and Fixing mat finish stainless steel (of 302 grade) railing with top pipe of 50 milimetre diameter and vertical pipe of 38 milimetre diameter at 0.60 metre center to center or as required and horizontal pipes of 25 milimetre diameter in three rows, all pipes of 2 milimetre thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 milimetre diameter above newel post of 75 milimetre diameter etc. complete (Prior approval of sample and brand by Ex.Engineer is necessary before use). Ground Floor

73.93

-

-

... More
Providing and Fixing mat finish stainless steel (of 302 grade) railing with top pipe of 50 milimetre diameter and vertical pipe of 38 milimetre diameter at 0.60 metre center to center or as required and horizontal pipes of 25 milimetre diameter in three rows, all pipes of 2 milimetre thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 milimetre diameter above newel post of 75 milimetre diameter etc. complete (Prior approval of sample and brand by Ex.Engineer is necessary before use). First Floor

131.93

-

-

... More
Providing and Fixing mat finish stainless steel (of 302 grade) railing with top pipe of 50 milimetre diameter and vertical pipe of 38 milimetre diameter at 0.60 metre center to center or as required and horizontal pipes of 25 milimetre diameter in three rows, all pipes of 2 milimetre thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 milimetre diameter above newel post of 75 milimetre diameter etc. complete (Prior approval of sample and brand by Ex.Engineer is necessary before use). Second Floor

124.93

-

-

... More
Providing and Fixing mat finish stainless steel (of 302 grade) railing with top pipe of 50 milimetre diameter and vertical pipe of 38 milimetre diameter at 0.60 metre center to center or as required and horizontal pipes of 25 milimetre diameter in three rows, all pipes of 2 milimetre thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 milimetre diameter above newel post of 75 milimetre diameter etc. complete (Prior approval of sample and brand by Ex.Engineer is necessary before use). Third Floor

124.93

-

-

... More
Providing and Fixing mat finish stainless steel (of 302 grade) railing with top pipe of 50 milimetre diameter and vertical pipe of 38 milimetre diameter at 0.60 metre center to center or as required and horizontal pipes of 25 milimetre diameter in three rows, all pipes of 2 milimetre thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 milimetre diameter above newel post of 75 milimetre diameter etc. complete (Prior approval of sample and brand by Ex.Engineer is necessary before use). Fourth Floor

124.93

-

-

... More
Providing and Fixing mat finish stainless steel (of 302 grade) railing with top pipe of 50 milimetre diameter and vertical pipe of 38 milimetre diameter at 0.60 metre center to center or as required and horizontal pipes of 25 milimetre diameter in three rows, all pipes of 2 milimetre thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 milimetre diameter above newel post of 75 milimetre diameter etc. complete (Prior approval of sample and brand by Ex.Engineer is necessary before use). Fifth Floor

21

-

-

... More
Providing and fixing mild steel grill railing 20 kilogram per square metre with teak wood hand rail of size 75 milimetre x 60 milimetre and sill of 75 milimetre.x 25 milimetre and newel posts for staircases, including fabricating, fixtures, erecting, painting the grill work with one coat of anticorrosive paint and two coats of oil painting with approved colour and polishing the sill, hand rail and the newel post with french polish. First Floor

223.62

-

-

... More
Providing and fixing mild steel grill railing 20 kilogram per square metre with teak wood hand rail of size 75 milimetre x 60 milimetre and sill of 75 milimetre.x 25 milimetre and newel posts for staircases, including fabricating, fixtures, erecting, painting the grill work with one coat of anticorrosive paint and two coats of oil painting with approved colour and polishing the sill, hand rail and the newel post with french polish. Second Floor

140.7

-

-

... More
Providing and fixing mild steel grill railing 20 kilogram per square metre with teak wood hand rail of size 75 milimetre x 60 milimetre and sill of 75 milimetre.x 25 milimetre and newel posts for staircases, including fabricating, fixtures, erecting, painting the grill work with one coat of anticorrosive paint and two coats of oil painting with approved colour and polishing the sill, hand rail and the newel post with french polish. Third Floor

219.07

-

-

... More
Providing and fixing mild steel grill railing 20 kilogram per square metre with teak wood hand rail of size 75 milimetre x 60 milimetre and sill of 75 milimetre.x 25 milimetre and newel posts for staircases, including fabricating, fixtures, erecting, painting the grill work with one coat of anticorrosive paint and two coats of oil painting with approved colour and polishing the sill, hand rail and the newel post with french polish. Fourth Floor

165.06

-

-

... More
Providing and fixing mild steel grill railing 20 kilogram per square metre with teak wood hand rail of size 75 milimetre x 60 milimetre and sill of 75 milimetre.x 25 milimetre and newel posts for staircases, including fabricating, fixtures, erecting, painting the grill work with one coat of anticorrosive paint and two coats of oil painting with approved colour and polishing the sill, hand rail and the newel post with french polish. Fifth Floor

78.1

-

-

... More
Providing and fixing 40 milimetre diameter and 1.5 milimetre thick Stainless steel hand railing in S.S. 304 Grade including fabricating, fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe complete. Ground Floor

66.93

-

-

... More
Providing and fixing 40 milimetre diameter and 1.5 milimetre thick Stainless steel hand railing in S.S. 304 Grade including fabricating, fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe complete. First Floor

66.93

-

-

... More
Providing and fixing 40 milimetre diameter and 1.5 milimetre thick Stainless steel hand railing in S.S. 304 Grade including fabricating, fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe complete. Second Floor

66.93

-

-

... More
Providing and fixing 40 milimetre diameter and 1.5 milimetre thick Stainless steel hand railing in S.S. 304 Grade including fabricating, fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe complete. Third Floor

66.93

-

-

... More
Providing and fixing 40 milimetre diameter and 1.5 milimetre thick Stainless steel hand railing in S.S. 304 Grade including fabricating, fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe complete. Fourth Floor

66.93

-

-

... More
Providing and fixing 40 milimetre diameter and 1.5 milimetre thick Stainless steel hand railing in S.S. 304 Grade including fabricating, fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe complete. Fifth Floor

21

-

-

... More
Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 milimetre x 450 milimetre size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 milimetre thick supports with kadappah top 35 to 40 milimetre thick and polished granite 16 to 20 milimetre top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 centimetre height and top granite of 75 x 40 centimetre including cutting, opening for sink of required size in kadappah as well as granite etc. complete. Ground Floor

18.94

-

-

... More
Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 milimetre x 450 milimetre size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 milimetre thick supports with kadappah top 35 to 40 milimetre thick and polished granite 16 to 20 milimetre top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 centimetre height and top granite of 75 x 40 centimetre including cutting, opening for sink of required size in kadappah as well as granite etc. complete. First Floor

71.7

-

-

... More
Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 milimetre x 450 milimetre size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 milimetre thick supports with kadappah top 35 to 40 milimetre thick and polished granite 16 to 20 milimetre top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 centimetre height and top granite of 75 x 40 centimetre including cutting, opening for sink of required size in kadappah as well as granite etc. complete. Second Floor

71.7

-

-

... More
Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 milimetre x 450 milimetre size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 milimetre thick supports with kadappah top 35 to 40 milimetre thick and polished granite 16 to 20 milimetre top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 centimetre height and top granite of 75 x 40 centimetre including cutting, opening for sink of required size in kadappah as well as granite etc. complete. Third Floor

71.7

-

-

... More
Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 milimetre x 450 milimetre size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 milimetre thick supports with kadappah top 35 to 40 milimetre thick and polished granite 16 to 20 milimetre top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 centimetre height and top granite of 75 x 40 centimetre including cutting, opening for sink of required size in kadappah as well as granite etc. complete. Fourth Floor

71.7

-

-

... More
Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 milimetre x 450 milimetre size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 milimetre thick supports with kadappah top 35 to 40 milimetre thick and polished granite 16 to 20 milimetre top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 centimetre height and top granite of 75 x 40 centimetre including cutting, opening for sink of required size in kadappah as well as granite etc. complete. Fifth Floor

37.13

-

-

... More
Providing and fixing sink cock with regular swinging spout (Wall Mounted Model) with wall flange with approved make incluidng other necessary fitting, etc. complete as directed by Engineer in charge. Ground Floor

10

-

-

... More
Providing and fixing sink cock with regular swinging spout (Wall Mounted Model) with wall flange with approved make incluidng other necessary fitting, etc. complete as directed by Engineer in charge. First Floor

40

-

-

... More
Providing and fixing sink cock with regular swinging spout (Wall Mounted Model) with wall flange with approved make incluidng other necessary fitting, etc. complete as directed by Engineer in charge. Second Floor

40

-

-

... More
Providing and fixing sink cock with regular swinging spout (Wall Mounted Model) with wall flange with approved make incluidng other necessary fitting, etc. complete as directed by Engineer in charge. Third Floor

40

-

-

... More
Providing and fixing sink cock with regular swinging spout (Wall Mounted Model) with wall flange with approved make incluidng other necessary fitting, etc. complete as directed by Engineer in charge. Fourth Floor

40

-

-

... More
Providing and fixing sink cock with regular swinging spout (Wall Mounted Model) with wall flange with approved make incluidng other necessary fitting, etc. complete as directed by Engineer in charge. Fifth Floor

20

-

-

... More
Providing and fixing white european type wall-hung pan, of size 350 milimetre x 355 milimetre x 570 milimetre concealed flush tank with floor-mounting frame installing kit and drain pipe connection set for wall hung WC, with approved make square control plates including soil pipe, vent pipe upto the outside face of wall, 100 milimetre dia C.I. plug bend inlet pipe all fittings,cutting & making good walls, floors etc. complete. Ground Floor

10

-

-

... More
Providing and fixing white european type wall-hung pan, of size 350 milimetre x 355 milimetre x 570 milimetre concealed flush tank with floor-mounting frame installing kit and drain pipe connection set for wall hung WC, with approved make square control plates including soil pipe, vent pipe upto the outside face of wall, 100 milimetre dia C.I. plug bend inlet pipe all fittings,cutting & making good walls, floors etc. complete. First Floor

44

-

-

... More
Providing and fixing white european type wall-hung pan, of size 350 milimetre x 355 milimetre x 570 milimetre concealed flush tank with floor-mounting frame installing kit and drain pipe connection set for wall hung WC, with approved make square control plates including soil pipe, vent pipe upto the outside face of wall, 100 milimetre dia C.I. plug bend inlet pipe all fittings,cutting & making good walls, floors etc. complete. Second Floor

40

-

-

... More
Providing and fixing white european type wall-hung pan, of size 350 milimetre x 355 milimetre x 570 milimetre concealed flush tank with floor-mounting frame installing kit and drain pipe connection set for wall hung WC, with approved make square control plates including soil pipe, vent pipe upto the outside face of wall, 100 milimetre dia C.I. plug bend inlet pipe all fittings,cutting & making good walls, floors etc. complete. Third Floor

49

-

-

... More
Providing and fixing white european type wall-hung pan, of size 350 milimetre x 355 milimetre x 570 milimetre concealed flush tank with floor-mounting frame installing kit and drain pipe connection set for wall hung WC, with approved make square control plates including soil pipe, vent pipe upto the outside face of wall, 100 milimetre dia C.I. plug bend inlet pipe all fittings,cutting & making good walls, floors etc. complete. Fourth Floor

42

-

-

... More
Providing and fixing white european type wall-hung pan, of size 350 milimetre x 355 milimetre x 570 milimetre concealed flush tank with floor-mounting frame installing kit and drain pipe connection set for wall hung WC, with approved make square control plates including soil pipe, vent pipe upto the outside face of wall, 100 milimetre dia C.I. plug bend inlet pipe all fittings,cutting & making good walls, floors etc. complete. Fifth Floor

24

-

-

... More
Providing and fixing Oval Type Under Counter Wash Hand Basin of 420 x 590 x 195 milimetre size with pillar cock, C.P.Angular stop cock, long thread of approved make continental including SS bottle trap of necessary pipe connection up to the outside face of the wall, having Telephonic Black / Colour Granite of 180 milimetre thick fixed on Black Kadappa Framework, etc. Complete as directed by Engineer in charge. Ground Floor

26

-

-

... More
Providing and fixing Oval Type Under Counter Wash Hand Basin of 420 x 590 x 195 milimetre size with pillar cock, C.P.Angular stop cock, long thread of approved make continental including SS bottle trap of necessary pipe connection up to the outside face of the wall, having Telephonic Black / Colour Granite of 180 milimetre thick fixed on Black Kadappa Framework, etc. Complete as directed by Engineer in charge. First Floor

23

-

-

... More
Providing and fixing Oval Type Under Counter Wash Hand Basin of 420 x 590 x 195 milimetre size with pillar cock, C.P.Angular stop cock, long thread of approved make continental including SS bottle trap of necessary pipe connection up to the outside face of the wall, having Telephonic Black / Colour Granite of 180 milimetre thick fixed on Black Kadappa Framework, etc. Complete as directed by Engineer in charge. Second Floor

19

-

-

... More
Providing and fixing Oval Type Under Counter Wash Hand Basin of 420 x 590 x 195 milimetre size with pillar cock, C.P.Angular stop cock, long thread of approved make continental including SS bottle trap of necessary pipe connection up to the outside face of the wall, having Telephonic Black / Colour Granite of 180 milimetre thick fixed on Black Kadappa Framework, etc. Complete as directed by Engineer in charge. Third Floor

31

-

-

... More
Providing and fixing Oval Type Under Counter Wash Hand Basin of 420 x 590 x 195 milimetre size with pillar cock, C.P.Angular stop cock, long thread of approved make continental including SS bottle trap of necessary pipe connection up to the outside face of the wall, having Telephonic Black / Colour Granite of 180 milimetre thick fixed on Black Kadappa Framework, etc. Complete as directed by Engineer in charge. Fourth Floor

20

-

-

... More
Providing and fixing Orissa Pan of size 580x445x260 milimetre with approved make flush valve including trap, C.I. soil and vent pipe upto outside face of wall including 100 milimetre dia. C.I. plug, bend and necessary pipe connection, etc complete. As directed by Engineer in charge. Ground Floor

2

-

-

... More
Providing and fixing Orissa Pan of size 580x445x260 milimetre with approved make flush valve including trap, C.I. soil and vent pipe upto outside face of wall including 100 milimetre dia. C.I. plug, bend and necessary pipe connection, etc complete. As directed by Engineer in charge. First Floor

6

-

-

... More
Providing and fixing Orissa Pan of size 580x445x260 milimetre with approved make flush valve including trap, C.I. soil and vent pipe upto outside face of wall including 100 milimetre dia. C.I. plug, bend and necessary pipe connection, etc complete. As directed by Engineer in charge. Second Floor

6

-

-

... More
Providing and fixing Orissa Pan of size 580x445x260 milimetre with approved make flush valve including trap, C.I. soil and vent pipe upto outside face of wall including 100 milimetre dia. C.I. plug, bend and necessary pipe connection, etc complete. As directed by Engineer in charge. Third Floor

6

-

-

... More
Providing and fixing Orissa Pan of size 580x445x260 milimetre with approved make flush valve including trap, C.I. soil and vent pipe upto outside face of wall including 100 milimetre dia. C.I. plug, bend and necessary pipe connection, etc complete. As directed by Engineer in charge. Fourth Floor

6

-

-

... More
Providing and fixing Table top white wash basin of size 120x635x405 milimetre rubber plugs and brass chain, with pillar cock, C.P.Angular stop cock long thread, continental including S.S. bottle trap of approved make having necessary pipe connection up to theoutside face of the wall.etc complete as directed by Engineer in charge. Ground Floor

3

-

-

... More
Providing and fixing Table top white wash basin of size 120x635x405 milimetre rubber plugs and brass chain, with pillar cock, C.P.Angular stop cock long thread, continental including S.S. bottle trap of approved make having necessary pipe connection up to theoutside face of the wall.etc complete as directed by Engineer in charge. First Floor

4

-

-

... More
Providing and fixing Table top white wash basin of size 120x635x405 milimetre rubber plugs and brass chain, with pillar cock, C.P.Angular stop cock long thread, continental including S.S. bottle trap of approved make having necessary pipe connection up to theoutside face of the wall.etc complete as directed by Engineer in charge. Second Floor

2

-

-

... More
Providing and fixing Table top white wash basin of size 120x635x405 milimetre rubber plugs and brass chain, with pillar cock, C.P.Angular stop cock long thread, continental including S.S. bottle trap of approved make having necessary pipe connection up to theoutside face of the wall.etc complete as directed by Engineer in charge. Third Floor

2

-

-

... More
Providing and fixing Table top white wash basin of size 120x635x405 milimetre rubber plugs and brass chain, with pillar cock, C.P.Angular stop cock long thread, continental including S.S. bottle trap of approved make having necessary pipe connection up to theoutside face of the wall.etc complete as directed by Engineer in charge. Fourth Floor

2

-

-

... More
Providing and fixing C.P. 2 Way BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge. Ground Floor

10

-

-

... More
Providing and fixing C.P. 2 Way BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge. First Floor

44

-

-

... More
Providing and fixing C.P. 2 Way BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge. Second Floor

40

-

-

... More
Providing and fixing C.P. 2 Way BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge. Third Floor

49

-

-

... More
Providing and fixing C.P. 2 Way BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge. Fourth Floor

42

-

-

... More
Providing and fixing C.P. 2 Way BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge. Fifth Floor

20

-

-

... More
Providing & fixing 15 milimetre diameter Poly Vinyl Chloride Aqua kraft type of approved make super jet spray with flange 2 in 1 faucet 1.50 metre long including all accessories etc. complete. Ground Floor

10

-

-

... More
Providing & fixing 15 milimetre diameter Poly Vinyl Chloride Aqua kraft type of approved make super jet spray with flange 2 in 1 faucet 1.50 metre long including all accessories etc. complete. First Floor

44

-

-

... More
Providing & fixing 15 milimetre diameter Poly Vinyl Chloride Aqua kraft type of approved make super jet spray with flange 2 in 1 faucet 1.50 metre long including all accessories etc. complete. Second Floor

40

-

-

... More
Providing & fixing 15 milimetre diameter Poly Vinyl Chloride Aqua kraft type of approved make super jet spray with flange 2 in 1 faucet 1.50 metre long including all accessories etc. complete. Third Floor

49

-

-

... More
Providing & fixing 15 milimetre diameter Poly Vinyl Chloride Aqua kraft type of approved make super jet spray with flange 2 in 1 faucet 1.50 metre long including all accessories etc. complete. Fourth Floor

42

-

-

... More
Providing & fixing 15 milimetre diameter Poly Vinyl Chloride Aqua kraft type of approved make super jet spray with flange 2 in 1 faucet 1.50 metre long including all accessories etc. complete. Fifth Floor

20

-

-

... More
Providing and fixing Shower Head, with shower arm of approved make mixer of including all necessary pipe fittings and connections etc. complete as directed by Engineer in charge. Ground Floor

1

-

-

... More
Providing and fixing Shower Head, with shower arm of approved make mixer of including all necessary pipe fittings and connections etc. complete as directed by Engineer in charge. First Floor

37

-

-

... More
Providing and fixing Shower Head, with shower arm of approved make mixer of including all necessary pipe fittings and connections etc. complete as directed by Engineer in charge. Second Floor

36

-

-

... More
Providing and fixing Shower Head, with shower arm of approved make mixer of including all necessary pipe fittings and connections etc. complete as directed by Engineer in charge. Third Floor

32

-

-

... More
Providing and fixing Shower Head, with shower arm of approved make mixer of including all necessary pipe fittings and connections etc. complete as directed by Engineer in charge. Fourth Floor

30

-

-

... More
Providing and fixing Shower Head, with shower arm of approved make mixer of including all necessary pipe fittings and connections etc. complete as directed by Engineer in charge. Fifth Floor

20

-

-

... More
Providing and fixing 15 cm rigid Poly Venyl Chloride Nahani trap including Poly Venyl Chloride grating, bend, connecting piece of Unplasticised Poly Venyl Chloride pipe up to the outside face of wall, making the good damaged surface and testing complete. ( Prior approval of sample and brand by Ex. Engr. is necessary before use). Ground Floor

88

-

-

... More
Providing and fixing 15 cm rigid Poly Venyl Chloride Nahani trap including Poly Venyl Chloride grating, bend, connecting piece of Unplasticised Poly Venyl Chloride pipe up to the outside face of wall, making the good damaged surface and testing complete. ( Prior approval of sample and brand by Ex. Engr. is necessary before use). First Floor

170

-

-

... More
Providing and fixing 15 cm rigid Poly Venyl Chloride Nahani trap including Poly Venyl Chloride grating, bend, connecting piece of Unplasticised Poly Venyl Chloride pipe up to the outside face of wall, making the good damaged surface and testing complete. ( Prior approval of sample and brand by Ex. Engr. is necessary before use). Second Floor

162

-

-

... More
Providing and fixing 15 cm rigid Poly Venyl Chloride Nahani trap including Poly Venyl Chloride grating, bend, connecting piece of Unplasticised Poly Venyl Chloride pipe up to the outside face of wall, making the good damaged surface and testing complete. ( Prior approval of sample and brand by Ex. Engr. is necessary before use). Third Floor

184

-

-

... More
Providing and fixing 15 cm rigid Poly Venyl Chloride Nahani trap including Poly Venyl Chloride grating, bend, connecting piece of Unplasticised Poly Venyl Chloride pipe up to the outside face of wall, making the good damaged surface and testing complete. ( Prior approval of sample and brand by Ex. Engr. is necessary before use). Fourth Floor

144

-

-

... More
Providing and fixing 15 cm rigid Poly Venyl Chloride Nahani trap including Poly Venyl Chloride grating, bend, connecting piece of Unplasticised Poly Venyl Chloride pipe up to the outside face of wall, making the good damaged surface and testing complete. ( Prior approval of sample and brand by Ex. Engr. is necessary before use). Fifth Floor

40

-

-

... More
Providing and fixing 15 centimetre x 10 centimetre salt glazed stoneware gully trap in cement concrete 1:4:8 out side the building including cast iron grating in the sink, connecting glazed stonewre pipe brick masonry chamber with cast iron lid and cast iron grating for the gully trap.

26

-

-

... More
Providing and fixing on walls / ceiling / floor 15 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete. Ground Floor

244.5

-

-

... More
Providing and fixing on walls / ceiling / floor 15 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete. First Floor

467.5

-

-

... More
Providing and fixing on walls / ceiling / floor 15 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete. Second Floor

445.5

-

-

... More
Providing and fixing on walls / ceiling / floor 15 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete. Third Floor

506

-

-

... More
Providing and fixing on walls / ceiling / floor 15 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete. Fourth Floor

396

-

-

... More
Providing and fixing on walls / ceiling / floor 15 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete. Fifth Floor

110

-

-

... More
Providing and fixing on walls / ceiling / floor 20 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete. Ground Floor

235.5

-

-

... More
Providing and fixing on walls / ceiling / floor 20 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete. First Floor

465.5

-

-

... More
Providing and fixing on walls / ceiling / floor 20 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete. Second Floor

445.5

-

-

... More
Providing and fixing on walls / ceiling / floor 20 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete. Third Floor

495

-

-

... More
Providing and fixing on walls / ceiling / floor 20 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete. Fourth Floor

385

-

-

... More
Providing and fixing on walls / ceiling / floor 20 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete. Fifth Floor

110

-

-

... More
Providing and fixing on walls / ceiling / floor 25 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete. Ground Floor

1554.5

-

-

... More
Providing and fixing on walls / ceiling / floor 25 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete. First Floor

465.5

-

-

... More
Providing and fixing on walls / ceiling / floor 25 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete. Second Floor

445.5

-

-

... More
Providing and fixing on walls / ceiling / floor 25 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete. Third Floor

495

-

-

... More
Providing and fixing on walls / ceiling / floor 25 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete. Fourth Floor

385

-

-

... More
Providing and fixing on walls / ceiling / floor 25 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete. Fifth Floor

110

-

-

... More
Providing and fixing on walls / ceiling / floor 32 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete. Ground Floor

584.5

-

-

... More
Providing and fixing on walls / ceiling / floor 32 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete. First Floor

363.2

-

-

... More
Providing and fixing on walls / ceiling / floor 32 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete. Second Floor

357

-

-

... More
Providing and fixing on walls / ceiling / floor 32 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete. Third Floor

378

-

-

... More
Providing and fixing on walls / ceiling / floor 32 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete. Fourth Floor

294

-

-

... More
Providing and fixing on walls / ceiling / floor 32 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete. Fifth Floor

84

-

-

... More
Providing and fixing on walls / ceiling / floor 40 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete. Ground Floor

270

-

-

... More
Providing and fixing on walls / ceiling / floor 40 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete. First Floor

112.2

-

-

... More
Providing and fixing on walls / ceiling / floor 40 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete. Second Floor

112.2

-

-

... More
Providing and fixing on walls / ceiling / floor 40 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete. Third Floor

103.8

-

-

... More
Providing and fixing on walls / ceiling / floor 40 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete. Fourth Floor

103.8

-

-

... More
Providing and fixing on walls / ceiling / floor 40 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete. Fifth Floor

42

-

-

... More
Providing and fixing on walls / ceiling / floor 50 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion complete. Ground Floor

400

-

-

... More
Providing and fixing on walls / ceiling / floor 50 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion complete. First Floor

112.2

-

-

... More
Providing and fixing on walls / ceiling / floor 50 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion complete. Second Floor

112.2

-

-

... More
Providing and fixing on walls / ceiling / floor 50 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion complete. Third Floor

103.8

-

-

... More
Providing and fixing on walls / ceiling / floor 50 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion complete. Fourth Floor

103.8

-

-

... More
Providing and fixing on walls / ceiling / floor 50 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion complete. Fifth Floor

42

-

-

... More
Providing and fixing 20 milimetre diameter screw down bib/ stop tap of brass including necessary socket union nut complete. Ground Floor

27

-

-

... More
Providing and fixing 20 milimetre diameter screw down bib/ stop tap of brass including necessary socket union nut complete. First Floor

28

-

-

... More
Providing and fixing 20 milimetre diameter screw down bib/ stop tap of brass including necessary socket union nut complete. Second Floor

26

-

-

... More
Providing and fixing 20 milimetre diameter screw down bib/ stop tap of brass including necessary socket union nut complete. Third Floor

26

-

-

... More
Providing and fixing 20 milimetre diameter screw down bib/ stop tap of brass including necessary socket union nut complete. Fourth Floor

26

-

-

... More
Providing and fixing 20 milimetre diameter screw down bib/ stop tap of brass including necessary socket union nut complete. Fifth Floor

10

-

-

... More
Providing and fixing screw down 15 milimetre diameter wheeled stop tap of brass including necessary sockets/union nut complete. Ground Floor

5

-

-

... More
Providing and fixing screw down 15 milimetre diameter wheeled stop tap of brass including necessary sockets/union nut complete. First Floor

22

-

-

... More
Providing and fixing screw down 15 milimetre diameter wheeled stop tap of brass including necessary sockets/union nut complete. Second Floor

20

-

-

... More
Providing and fixing screw down 15 milimetre diameter wheeled stop tap of brass including necessary sockets/union nut complete. Third Floor

18

-

-

... More
Providing and fixing screw down 15 milimetre diameter wheeled stop tap of brass including necessary sockets/union nut complete. Fourth Floor

18

-

-

... More
Providing and fixing screw down 15 milimetre diameter wheeled stop tap of brass including necessary sockets/union nut complete. Fifth Floor

10

-

-

... More
Providing and fixing screw down for 25 milimetre diameter wheeled stop tap of brass including necessary sockets/union nut complete. Ground Floor

17

-

-

... More
Providing and fixing screw down for 25 milimetre diameter wheeled stop tap of brass including necessary sockets/union nut complete. First Floor

22

-

-

... More
Providing and fixing screw down for 25 milimetre diameter wheeled stop tap of brass including necessary sockets/union nut complete. Second Floor

20

-

-

... More
Providing and fixing screw down for 25 milimetre diameter wheeled stop tap of brass including necessary sockets/union nut complete. Third Floor

18

-

-

... More
Providing and fixing screw down for 25 milimetre diameter wheeled stop tap of brass including necessary sockets/union nut complete. Fourth Floor

26

-

-

... More
Providing and fixing screw down for 25 milimetre diameter wheeled stop tap of brass including necessary sockets/union nut complete. Fifth Floor

10

-

-

... More
Providing and fixing screw down for 32 milimetre diameter wheeled stop tap of brass including necessary sockets/union nut complete. Ground Floor

21

-

-

... More
Providing and fixing screw down for 32 milimetre diameter wheeled stop tap of brass including necessary sockets/union nut complete. First Floor

21

-

-

... More
Providing and fixing screw down for 32 milimetre diameter wheeled stop tap of brass including necessary sockets/union nut complete. Second Floor

20

-

-

... More
Providing and fixing screw down for 32 milimetre diameter wheeled stop tap of brass including necessary sockets/union nut complete. Third Floor

17

-

-

... More
Providing and fixing screw down for 32 milimetre diameter wheeled stop tap of brass including necessary sockets/union nut complete. Fourth Floor

17

-

-

... More
Providing and fixing screw down for 32 milimetre diameter wheeled stop tap of brass including necessary sockets/union nut complete. Fifth Floor

10

-

-

... More
Providing and fixing screw down for 40 milimetre diameter wheeled stop tap of brass including necessary sockets/union nut complete. Ground Floor

21

-

-

... More
Providing and fixing screw down for 40 milimetre diameter wheeled stop tap of brass including necessary sockets/union nut complete. First Floor

21

-

-

... More
Providing and fixing screw down for 40 milimetre diameter wheeled stop tap of brass including necessary sockets/union nut complete. Second Floor

20

-

-

... More
Providing and fixing screw down for 40 milimetre diameter wheeled stop tap of brass including necessary sockets/union nut complete. Third Floor

17

-

-

... More
Providing and fixing screw down for 40 milimetre diameter wheeled stop tap of brass including necessary sockets/union nut complete. Fourth Floor

17

-

-

... More
Providing and fixing screw down for 40 milimetre diameter wheeled stop tap of brass including necessary sockets/union nut complete. Fifth Floor

10

-

-

... More
Providing and fixing screw down for 50 milimetre diameter wheeled stop tap of brass including necessary sockets / union nut complete. Ground Floor

22

-

-

... More
Providing and fixing screw down for 50 milimetre diameter wheeled stop tap of brass including necessary sockets / union nut complete. First Floor

22

-

-

... More
Providing and fixing screw down for 50 milimetre diameter wheeled stop tap of brass including necessary sockets / union nut complete. Second Floor

20

-

-

... More
Providing and fixing screw down for 50 milimetre diameter wheeled stop tap of brass including necessary sockets / union nut complete. Third Floor

18

-

-

... More
Providing and fixing screw down for 50 milimetre diameter wheeled stop tap of brass including necessary sockets / union nut complete. Fourth Floor

18

-

-

... More
Providing and fixing screw down for 50 milimetre diameter wheeled stop tap of brass including necessary sockets / union nut complete. Fifth Floor

8

-

-

... More
Providing and fixing on walls/ ceiling/ floors, 50 milimetre diameter heavy grade having embossed as Indian Standard Institute Mark galvanised iron pipes of 6.33 kilogrames per metre with necessary fitting, remaking good the demolished portion and applying primer of anti-corrosive oil paint in 2 coats complete. Ground Floor

126

-

-

... More
Providing and fixing on walls/ ceiling/ floors, 50 milimetre diameter heavy grade having embossed as Indian Standard Institute Mark galvanised iron pipes of 6.33 kilogrames per metre with necessary fitting, remaking good the demolished portion and applying primer of anti-corrosive oil paint in 2 coats complete. First Floor

90

-

-

... More
Providing and fixing on walls/ ceiling/ floors, 50 milimetre diameter heavy grade having embossed as Indian Standard Institute Mark galvanised iron pipes of 6.33 kilogrames per metre with necessary fitting, remaking good the demolished portion and applying primer of anti-corrosive oil paint in 2 coats complete. Second Floor

76.5

-

-

... More
Providing and fixing on walls/ ceiling/ floors, 50 milimetre diameter heavy grade having embossed as Indian Standard Institute Mark galvanised iron pipes of 6.33 kilogrames per metre with necessary fitting, remaking good the demolished portion and applying primer of anti-corrosive oil paint in 2 coats complete. Third Floor

76.5

-

-

... More
Providing and fixing on walls/ ceiling/ floors, 50 milimetre diameter heavy grade having embossed as Indian Standard Institute Mark galvanised iron pipes of 6.33 kilogrames per metre with necessary fitting, remaking good the demolished portion and applying primer of anti-corrosive oil paint in 2 coats complete. Fourth Floor

76.5

-

-

... More
Providing and fixing on walls/ ceiling/ floors, 50 milimetre diameter heavy grade having embossed as Indian Standard Institute Mark galvanised iron pipes of 6.33 kilogrames per metre with necessary fitting, remaking good the demolished portion and applying primer of anti-corrosive oil paint in 2 coats complete. Fifth Floor

54

-

-

... More
Providing and fixing 75 milimetre diameter stabiliser pipe /Poly Venyl Chloride soil vent /waste pipe and with necessary fixtuers and fiting such as bends, tees, single junctions slotted vent, clamps complete. Ground Floor

224.4

-

-

... More
Providing and fixing 75 milimetre diameter stabiliser pipe /Poly Venyl Chloride soil vent /waste pipe and with necessary fixtuers and fiting such as bends, tees, single junctions slotted vent, clamps complete. First Floor

222.6

-

-

... More
Providing and fixing 75 milimetre diameter stabiliser pipe /Poly Venyl Chloride soil vent /waste pipe and with necessary fixtuers and fiting such as bends, tees, single junctions slotted vent, clamps complete. Second Floor

216

-

-

... More
Providing and fixing 75 milimetre diameter stabiliser pipe /Poly Venyl Chloride soil vent /waste pipe and with necessary fixtuers and fiting such as bends, tees, single junctions slotted vent, clamps complete. Third Floor

216

-

-

... More
Providing and fixing 75 milimetre diameter stabiliser pipe /Poly Venyl Chloride soil vent /waste pipe and with necessary fixtuers and fiting such as bends, tees, single junctions slotted vent, clamps complete. Fourth Floor

216

-

-

... More
Providing and fixing 75 milimetre diameter stabiliser pipe /Poly Venyl Chloride soil vent /waste pipe and with necessary fixtuers and fiting such as bends, tees, single junctions slotted vent, clamps complete. Fifth Floor

90

-

-

... More
Providing and fixing 100 milimetre diameter stabiliser pipe /Poly Venyl Chloride soil vent /waste pipe and with necessary fixtuers and fiting such as bends, tees, single junctions slotted vent, clamps complete. Ground Floor

225

-

-

... More
Providing and fixing 100 milimetre diameter stabiliser pipe /Poly Venyl Chloride soil vent /waste pipe and with necessary fixtuers and fiting such as bends, tees, single junctions slotted vent, clamps complete. First Floor

222.6

-

-

... More
Providing and fixing 100 milimetre diameter stabiliser pipe /Poly Venyl Chloride soil vent /waste pipe and with necessary fixtuers and fiting such as bends, tees, single junctions slotted vent, clamps complete. Second Floor

216

-

-

... More
Providing and fixing 100 milimetre diameter stabiliser pipe /Poly Venyl Chloride soil vent /waste pipe and with necessary fixtuers and fiting such as bends, tees, single junctions slotted vent, clamps complete. Third Floor

216

-

-

... More
Providing and fixing 100 milimetre diameter stabiliser pipe /Poly Venyl Chloride soil vent /waste pipe and with necessary fixtuers and fiting such as bends, tees, single junctions slotted vent, clamps complete. Fourth Floor

216

-

-

... More
Providing and fixing 100 milimetre diameter stabiliser pipe /Poly Venyl Chloride soil vent /waste pipe and with necessary fixtuers and fiting such as bends, tees, single junctions slotted vent, clamps complete. Fifth Floor

90

-

-

... More
Providing and fixing Poly Venyl Chloride Rain water pipes of 160 milimetre outer diameter and having wall thickness of 2.2 to 2.7 milimetre confirming to Indian Standard 13592-1992 including proper rainwater receiving recess with Poly Venyl Chloride plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25 milimetre to 40milimetre from face of wall a fixing with clips of approved quality and number, filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on Cement Concrete or masonry blocks, including necessary scaffolding and maintenance for 3 years for any leakages or dislocations of pipes. All the Poly Venyl Chloride fittings and additional 2 piece socket clips shall be got approved from engineer in charge complete. (The contractor shall give 3 years guarantee bond for payment). Ground Floor

240

-

-

... More
Providing and fixing Poly Venyl Chloride Rain water pipes of 160 milimetre outer diameter and having wall thickness of 2.2 to 2.7 milimetre confirming to Indian Standard 13592-1992 including proper rainwater receiving recess with Poly Venyl Chloride plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25 milimetre to 40milimetre from face of wall a fixing with clips of approved quality and number, filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on Cement Concrete or masonry blocks, including necessary scaffolding and maintenance for 3 years for any leakages or dislocations of pipes. All the Poly Venyl Chloride fittings and additional 2 piece socket clips shall be got approved from engineer in charge complete. (The contractor shall give 3 years guarantee bond for payment). First Floor

208.2

-

-

... More
Providing and fixing Poly Venyl Chloride Rain water pipes of 160 milimetre outer diameter and having wall thickness of 2.2 to 2.7 milimetre confirming to Indian Standard 13592-1992 including proper rainwater receiving recess with Poly Venyl Chloride plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25 milimetre to 40milimetre from face of wall a fixing with clips of approved quality and number, filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on Cement Concrete or masonry blocks, including necessary scaffolding and maintenance for 3 years for any leakages or dislocations of pipes. All the Poly Venyl Chloride fittings and additional 2 piece socket clips shall be got approved from engineer in charge complete. (The contractor shall give 3 years guarantee bond for payment). Second Floor

201.6

-

-

... More
Providing and fixing Poly Venyl Chloride Rain water pipes of 160 milimetre outer diameter and having wall thickness of 2.2 to 2.7 milimetre confirming to Indian Standard 13592-1992 including proper rainwater receiving recess with Poly Venyl Chloride plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25 milimetre to 40milimetre from face of wall a fixing with clips of approved quality and number, filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on Cement Concrete or masonry blocks, including necessary scaffolding and maintenance for 3 years for any leakages or dislocations of pipes. All the Poly Venyl Chloride fittings and additional 2 piece socket clips shall be got approved from engineer in charge complete. (The contractor shall give 3 years guarantee bond for payment). Third Floor

201.6

-

-

... More
Providing and fixing Poly Venyl Chloride Rain water pipes of 160 milimetre outer diameter and having wall thickness of 2.2 to 2.7 milimetre confirming to Indian Standard 13592-1992 including proper rainwater receiving recess with Poly Venyl Chloride plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25 milimetre to 40milimetre from face of wall a fixing with clips of approved quality and number, filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on Cement Concrete or masonry blocks, including necessary scaffolding and maintenance for 3 years for any leakages or dislocations of pipes. All the Poly Venyl Chloride fittings and additional 2 piece socket clips shall be got approved from engineer in charge complete. (The contractor shall give 3 years guarantee bond for payment). Fourth Floor

201.6

-

-

... More
Providing and fixing Poly Venyl Chloride Rain water pipes of 160 milimetre outer diameter and having wall thickness of 2.2 to 2.7 milimetre confirming to Indian Standard 13592-1992 including proper rainwater receiving recess with Poly Venyl Chloride plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25 milimetre to 40milimetre from face of wall a fixing with clips of approved quality and number, filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on Cement Concrete or masonry blocks, including necessary scaffolding and maintenance for 3 years for any leakages or dislocations of pipes. All the Poly Venyl Chloride fittings and additional 2 piece socket clips shall be got approved from engineer in charge complete. (The contractor shall give 3 years guarantee bond for payment). Fifth Floor

100.8

-

-

... More
Providing and laying concrete pipe of Indian Standard Non Pressure class of 100 milimetre diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.

531.32

-

-

... More
Providing and laying concrete pipe of Indian Standard Non Pressure class of 150 milimetre diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.

560

-

-

... More
Providing and laying concrete pipe of Indian Standard Non Pressure class of 225 milimetre diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.

770

-

-

... More
Providing and laying concrete pipe of Indian Standard Non Pressure class of 300 milimetre diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.

919

-

-

... More
Providing and constructing Brick Masonry Inspection Chamber 60 centimetre x 45 centimetre x 90 centimetre including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round Glazed Stone Ware pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with Reinforced Cement Concrete cover medium duty 140 kilogram with frame etc. complete.

98

-

-

... More
Providing and constructing Brick Masonry Inspection Chamber 90 centimetre x 45 centimetre x 90 centimetre including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round Glazed Stone Ware pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with Reinforced Cement Concrete cover medium duty 140 kilogram with frame etc. complete.

169

-

-

... More
Providing and fixing High Density Polymer container Syntex or alike one piece moulded water tank made out of high density polythyler and built corrugated inclusive of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow pipe inclusive of all tanks capacity between 1000 to 20000 liters.

96000

-

-

... More
Supply and Installation of Dpi Flux translucent roof with standing seam multicell polycarbonate panel system. The system with complete assembly of co extruded UV protected multicell panels incorporated into a complete system. Co-extruded UV protected polycarbonate panel system of min 16 mm thick of 1200mm (min.) width with angular daylighting concept. Panels shall have minimum seven layers in a truss bridge design for higher flexibility & strength. Panels with opaque and translucent clear combination as per required lux level and design requirements with all fixing accessories to ensure best performance for wind uplift, vibration, oil canning and visual appearance. Panels shall have an additional IR Blocking features for enhance thermal comfort. Panels shall be manufactured with vertical standing seam at both sides of the panel. Panels shall be fixed on Purlin with snap on connectors with double tooth grip lock locking mechanism and will be secured on MS structure (will be paid Separately) with 3 numbers self-drilling screws & trapezoid SS fasteners holding the base of the standing seam offering best stability having a pull-out load of

329.41

-

-

... More
Providing, fabricating and erecting at site of work the tubular steel structure (shed) as per standard design and specifications having various spans in between trusses and in multiples of standard length of bays as specified as per standard specifications, inclusive of cost of steel tubular trusses, tubular columns purlins, tie runners, foundation bolts, base plates, nuts and bolts, welding wherever required etc. as per detailed drawing inclusive of one coat of anticorrosive paint and two coats of oil painting of approved quality and shade etc. complete.

21.05

-

-

... More
Providing and fixing 90 centimetre x 60 centimetre Granite plate engraving 10 centimetre height letter, figures including painting the letters/ figures with approved colour and shade complete.

2

-

-

... More
Providing and laying in situ/ Ready Mix cement concrete Mix-25 of trap/ granite/quartzite/ gneiss metal for Reinforced Cement Concrete work in foundations like raft, strip foundations, grillage and footings of Reinforced Cement Concrete columns and steel stanchions etc. including bailing out water, formwork, laying/ pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided, (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade).

383.95

-

-

... More
Providing and laying cast in situ/ Ready Mix cement concrete Mix-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete columns as per detailed designs and drawing or as directed including centering, formwork, cover blocks, laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade). Ground Floor

253.1

-

-

... More
Providing and laying cast in situ/ Ready Mix cement concrete Mix-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete columns as per detailed designs and drawing or as directed including centering, formwork, cover blocks, laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade). First Floor

129.48

-

-

... More
Providing and laying cast in situ/ Ready Mix cement concrete Mix-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete columns as per detailed designs and drawing or as directed including centering, formwork, cover blocks, laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade). Second Floor

120.06

-

-

... More
Providing and laying cast in situ/ Ready Mix cement concrete Mix-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete columns as per detailed designs and drawing or as directed including centering, formwork, cover blocks, laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade). Third Floor

120.06

-

-

... More
Providing and laying cast in situ/ Ready Mix cement concrete Mix-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete columns as per detailed designs and drawing or as directed including centering, formwork, cover blocks, laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade). Fourth Floor

119.04

-

-

... More
Providing and laying cast in situ/ Ready Mix cement concrete Mix-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete columns as per detailed designs and drawing or as directed including centering, formwork, cover blocks, laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade). Fifth Floor

136.44

-

-

... More
Providing and laying Cast in situ/ Ready Mix cement concrete Mix-25 of trap/ granite/quartzite/ gneiss metal for Reinforced Cement Concrete Beams and Lintels as per detailed designs and drawings or as directed including centering, formwork, cover blocks, laying/ pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel), with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade). Ground Floor

179.55

-

-

... More
Providing and laying Cast in situ/ Ready Mix cement concrete Mix-25 of trap/ granite/quartzite/ gneiss metal for Reinforced Cement Concrete Beams and Lintels as per detailed designs and drawings or as directed including centering, formwork, cover blocks, laying/ pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel), with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade). First Floor

97.7

-

-

... More
Providing and laying Cast in situ/ Ready Mix cement concrete Mix-25 of trap/ granite/quartzite/ gneiss metal for Reinforced Cement Concrete Beams and Lintels as per detailed designs and drawings or as directed including centering, formwork, cover blocks, laying/ pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel), with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade). Second Floor

88.6

-

-

... More
Providing and laying Cast in situ/ Ready Mix cement concrete Mix-25 of trap/ granite/quartzite/ gneiss metal for Reinforced Cement Concrete Beams and Lintels as per detailed designs and drawings or as directed including centering, formwork, cover blocks, laying/ pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel), with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade). Third Floor

88.6

-

-

... More
Providing and laying Cast in situ/ Ready Mix cement concrete Mix-25 of trap/ granite/quartzite/ gneiss metal for Reinforced Cement Concrete Beams and Lintels as per detailed designs and drawings or as directed including centering, formwork, cover blocks, laying/ pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel), with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade). Fourth Floor

92.21

-

-

... More
Providing and laying Cast in situ/ Ready Mix cement concrete Mix-25 of trap/ granite/quartzite/ gneiss metal for Reinforced Cement Concrete Beams and Lintels as per detailed designs and drawings or as directed including centering, formwork, cover blocks, laying/ pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel), with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade). Fifth Floor

78.5

-

-

... More
Providing and laying Cast in situ/ Ready Mix cement concrete Mix-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Slabs and Landings as per detailed designs and drawings including centering, formwork, cover blocks, laying/ pumping, compactionfinishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). Ground Floor

289.41

-

-

... More
Providing and laying Cast in situ/ Ready Mix cement concrete Mix-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Slabs and Landings as per detailed designs and drawings including centering, formwork, cover blocks, laying/ pumping, compactionfinishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). First Floor

152.04

-

-

... More
Providing and laying Cast in situ/ Ready Mix cement concrete Mix-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Slabs and Landings as per detailed designs and drawings including centering, formwork, cover blocks, laying/ pumping, compactionfinishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). Second Floor

142.43

-

-

... More
Providing and laying Cast in situ/ Ready Mix cement concrete Mix-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Slabs and Landings as per detailed designs and drawings including centering, formwork, cover blocks, laying/ pumping, compactionfinishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). Third Floor

142.43

-

-

... More
Providing and laying Cast in situ/ Ready Mix cement concrete Mix-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Slabs and Landings as per detailed designs and drawings including centering, formwork, cover blocks, laying/ pumping, compactionfinishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). Fourth Floor

153.31

-

-

... More
Providing and laying Cast in situ/ Ready Mix cement concrete Mix-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Slabs and Landings as per detailed designs and drawings including centering, formwork, cover blocks, laying/ pumping, compactionfinishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). Fifth Floor

134.73

-

-

... More
Providing and laying Cast in situ/ Ready Mix cement concrete in Mix-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Pardi of required thickness including centering, formwork, cover blocks, laying/ pumping, compacting, curing, finishing and rougheningthem if special finish is to be provided and curing complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). Ground Floor

154.02

-

-

... More
Providing and laying Cast in situ/ Ready Mix cement concrete in Mix-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Pardi of required thickness including centering, formwork, cover blocks, laying/ pumping, compacting, curing, finishing and rougheningthem if special finish is to be provided and curing complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). First Floor

14.59

-

-

... More
Providing and laying Cast in situ/ Ready Mix cement concrete in Mix-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Pardi of required thickness including centering, formwork, cover blocks, laying/ pumping, compacting, curing, finishing and rougheningthem if special finish is to be provided and curing complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). Second Floor

14.59

-

-

... More
Providing and laying Cast in situ/ Ready Mix cement concrete in Mix-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Pardi of required thickness including centering, formwork, cover blocks, laying/ pumping, compacting, curing, finishing and rougheningthem if special finish is to be provided and curing complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). Third Floor

14.59

-

-

... More
Providing and laying Cast in situ/ Ready Mix cement concrete in Mix-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Pardi of required thickness including centering, formwork, cover blocks, laying/ pumping, compacting, curing, finishing and rougheningthem if special finish is to be provided and curing complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). Fourth Floor

16.02

-

-

... More
Providing and laying Cast in situ/ Ready Mix cement concrete in Mix-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Pardi of required thickness including centering, formwork, cover blocks, laying/ pumping, compacting, curing, finishing and rougheningthem if special finish is to be provided and curing complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). Fifth Floor

36.48

-

-

... More
Providing and applying Texture plaster with finishing with Purlina/ Rustic texture material (with texture material of Asian/ Renava/ Nitco/Temtex or equivalent company make) in 3 to 4 millimeter thickness on previously finished plastered surface, including Plaster Groove 6 milimetre thickness or Tape Grooves 35 to 45 milimetre thickness or as required, in all position including preparing the surface scaffolding etc.complete. Ground Floor

62.42

-

-

... More
Providing and applying Texture plaster with finishing with Purlina/ Rustic texture material (with texture material of Asian/ Renava/ Nitco/Temtex or equivalent company make) in 3 to 4 millimeter thickness on previously finished plastered surface, including Plaster Groove 6 milimetre thickness or Tape Grooves 35 to 45 milimetre thickness or as required, in all position including preparing the surface scaffolding etc.complete. First Floor

368.9

-

-

... More
Providing and applying Texture plaster with finishing with Purlina/ Rustic texture material (with texture material of Asian/ Renava/ Nitco/Temtex or equivalent company make) in 3 to 4 millimeter thickness on previously finished plastered surface, including Plaster Groove 6 milimetre thickness or Tape Grooves 35 to 45 milimetre thickness or as required, in all position including preparing the surface scaffolding etc.complete. Second Floor

324.63

-

-

... More
Providing and applying Texture plaster with finishing with Purlina/ Rustic texture material (with texture material of Asian/ Renava/ Nitco/Temtex or equivalent company make) in 3 to 4 millimeter thickness on previously finished plastered surface, including Plaster Groove 6 milimetre thickness or Tape Grooves 35 to 45 milimetre thickness or as required, in all position including preparing the surface scaffolding etc.complete. Third Floor

324.63

-

-

... More
Providing and applying Texture plaster with finishing with Purlina/ Rustic texture material (with texture material of Asian/ Renava/ Nitco/Temtex or equivalent company make) in 3 to 4 millimeter thickness on previously finished plastered surface, including Plaster Groove 6 milimetre thickness or Tape Grooves 35 to 45 milimetre thickness or as required, in all position including preparing the surface scaffolding etc.complete. Fourth Floor

491.86

-

-

... More
Providing and applying Texture plaster with finishing with Purlina/ Rustic texture material (with texture material of Asian/ Renava/ Nitco/Temtex or equivalent company make) in 3 to 4 millimeter thickness on previously finished plastered surface, including Plaster Groove 6 milimetre thickness or Tape Grooves 35 to 45 milimetre thickness or as required, in all position including preparing the surface scaffolding etc.complete. Fifth Floor

616.59

-

-

... More
Providing and applying washable oil bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces including Primer Coat complete. Ground Floor

1002.59

-

-

... More
Providing and applying washable oil bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces including Primer Coat complete. First Floor

727.38

-

-

... More
Providing and applying washable oil bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces including Primer Coat complete. Second Floor

727.38

-

-

... More
Providing and applying washable oil bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces including Primer Coat complete. Third Floor

522.02

-

-

... More
Providing and applying washable oil bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces including Primer Coat complete. Fourth Floor

752.58

-

-

... More
Providing and applying washable oil bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces including Primer Coat complete. Fifth Floor

545.96

-

-

... More
Providing and applying Two coats of wall care Putty of 2 milimetre thickness for plastered surface and 5-6 milimetre thickness finished concrete surface to Ceiling and Walls to prepare surface even and smooth of Brands BIRLA WHITE, BERGER, BISION, J.K., make, etc complete for plastered walls/ceiling 2 mm. Ground Floor

949.84

-

-

... More
Providing and applying Two coats of wall care Putty of 2 milimetre thickness for plastered surface and 5-6 milimetre thickness finished concrete surface to Ceiling and Walls to prepare surface even and smooth of Brands BIRLA WHITE, BERGER, BISION, J.K., make, etc complete for plastered walls/ceiling 2 mm. First Floor

727.38

-

-

... More
Providing and applying Two coats of wall care Putty of 2 milimetre thickness for plastered surface and 5-6 milimetre thickness finished concrete surface to Ceiling and Walls to prepare surface even and smooth of Brands BIRLA WHITE, BERGER, BISION, J.K., make, etc complete for plastered walls/ceiling 2 mm. Second Floor

727.38

-

-

... More
Providing and applying Two coats of wall care Putty of 2 milimetre thickness for plastered surface and 5-6 milimetre thickness finished concrete surface to Ceiling and Walls to prepare surface even and smooth of Brands BIRLA WHITE, BERGER, BISION, J.K., make, etc complete for plastered walls/ceiling 2 mm. Third Floor

522.02

-

-

... More
Providing and applying Two coats of wall care Putty of 2 milimetre thickness for plastered surface and 5-6 milimetre thickness finished concrete surface to Ceiling and Walls to prepare surface even and smooth of Brands BIRLA WHITE, BERGER, BISION, J.K., make, etc complete for plastered walls/ceiling 2 mm. Fourth Floor

752.58

-

-

... More
Providing and applying Two coats of wall care Putty of 2 milimetre thickness for plastered surface and 5-6 milimetre thickness finished concrete surface to Ceiling and Walls to prepare surface even and smooth of Brands BIRLA WHITE, BERGER, BISION, J.K., make, etc complete for plastered walls/ceiling 2 mm. Fifth Floor

545.96

-

-

... More
Providing and laying vitrified mirror/ glossy finish tiles for Flooring of decorative type having size 590 milimetre to 605 milimetre x 590 milimetre to 605 milimetre of 8 to 10 milimetre thickness and confirming to Indian Standard 15622: 2006 (group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete. Ground Floor

14.26

-

-

... More
Providing and laying vitrified mirror/ glossy finish tiles for Flooring of decorative type having size 590 milimetre to 605 milimetre x 590 milimetre to 605 milimetre of 8 to 10 milimetre thickness and confirming to Indian Standard 15622: 2006 (group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete. First Floor

725.27

-

-

... More
Providing and laying vitrified mirror/ glossy finish tiles for Flooring of decorative type having size 590 milimetre to 605 milimetre x 590 milimetre to 605 milimetre of 8 to 10 milimetre thickness and confirming to Indian Standard 15622: 2006 (group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete. Second Floor

725.27

-

-

... More
Providing and laying vitrified mirror/ glossy finish tiles for Flooring of decorative type having size 590 milimetre to 605 milimetre x 590 milimetre to 605 milimetre of 8 to 10 milimetre thickness and confirming to Indian Standard 15622: 2006 (group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete. Third Floor

725.27

-

-

... More
Providing and laying vitrified mirror/ glossy finish tiles for Flooring of decorative type having size 590 milimetre to 605 milimetre x 590 milimetre to 605 milimetre of 8 to 10 milimetre thickness and confirming to Indian Standard 15622: 2006 (group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete. Fourth Floor

725.27

-

-

... More
Providing and laying vitrified mirror/ glossy finish tiles for Flooring of decorative type having size 590 milimetre to 605 milimetre x 590 milimetre to 605 milimetre of 8 to 10 milimetre thickness and confirming to Indian Standard 15622: 2006 (group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete. Fifth Floor

571.3

-

-

... More
Providing and laying vitrified mirror / glossy finish tiles for Skirting having size 590 milimetre to 605 milimetre x 590 milimetre to 605 milimetre of 8 to 10 milimetre thickness and confirming to IS. 15622-2006 (group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete. Ground Floor

1.28

-

-

... More
Providing and laying vitrified mirror / glossy finish tiles for Skirting having size 590 milimetre to 605 milimetre x 590 milimetre to 605 milimetre of 8 to 10 milimetre thickness and confirming to IS. 15622-2006 (group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete. First Floor

574.26

-

-

... More
Providing and laying vitrified mirror / glossy finish tiles for Skirting having size 590 milimetre to 605 milimetre x 590 milimetre to 605 milimetre of 8 to 10 milimetre thickness and confirming to IS. 15622-2006 (group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete. Second Floor

574.26

-

-

... More
Providing and laying vitrified mirror / glossy finish tiles for Skirting having size 590 milimetre to 605 milimetre x 590 milimetre to 605 milimetre of 8 to 10 milimetre thickness and confirming to IS. 15622-2006 (group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete. Third Floor

574.25

-

-

... More
Providing and laying vitrified mirror / glossy finish tiles for Skirting having size 590 milimetre to 605 milimetre x 590 milimetre to 605 milimetre of 8 to 10 milimetre thickness and confirming to IS. 15622-2006 (group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete. Fourth Floor

574.25

-

-

... More
Providing and laying vitrified mirror / glossy finish tiles for Skirting having size 590 milimetre to 605 milimetre x 590 milimetre to 605 milimetre of 8 to 10 milimetre thickness and confirming to IS. 15622-2006 (group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete. Fifth Floor

303.38

-

-

... More
Providing and laying Antiskid Ceramic tiles of approved quality of size 30 centimetre x 30 centimetre and conforming to Indian Standard 15622-2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete. First Floor

192.08

-

-

... More
Providing and laying Antiskid Ceramic tiles of approved quality of size 30 centimetre x 30 centimetre and conforming to Indian Standard 15622-2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete. Second Floor

192.08

-

-

... More
Providing and laying Antiskid Ceramic tiles of approved quality of size 30 centimetre x 30 centimetre and conforming to Indian Standard 15622-2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete. Third Floor

192.08

-

-

... More
Providing and laying Antiskid Ceramic tiles of approved quality of size 30 centimetre x 30 centimetre and conforming to Indian Standard 15622-2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete. Fourth Floor

192.08

-

-

... More
Providing and laying Antiskid Ceramic tiles of approved quality of size 30 centimetre x 30 centimetre and conforming to Indian Standard 15622-2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete. Fifth Floor

124.08

-

-

... More
Providing and laying chequered tiles of approved quality of size 30 centimetre x 30 centimetre for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete.

1191.35

-

-

... More
Providing and fixing in position aluminium fixed window fully glazed of any size with Powder Coating as per detailed drawing and as directed by Engineer in Charge with all necessary aluminium sections including necessary fixtures and fastening with 5 milimetre thick clear float glass etc. complete. Ground Floor

64.66

-

-

... More
Providing and fixing in position aluminium fixed window fully glazed of any size with Powder Coating as per detailed drawing and as directed by Engineer in Charge with all necessary aluminium sections including necessary fixtures and fastening with 5 milimetre thick clear float glass etc. complete. First Floor

8.64

-

-

... More
Providing and fixing in position aluminium fixed window fully glazed of any size with Powder Coating as per detailed drawing and as directed by Engineer in Charge with all necessary aluminium sections including necessary fixtures and fastening with 5 milimetre thick clear float glass etc. complete. Second Floor

8.64

-

-

... More
Providing and fixing in position aluminium fixed window fully glazed of any size with Powder Coating as per detailed drawing and as directed by Engineer in Charge with all necessary aluminium sections including necessary fixtures and fastening with 5 milimetre thick clear float glass etc. complete. Third Floor

8.64

-

-

... More
Providing and fixing in position aluminium fixed window fully glazed of any size with Powder Coating as per detailed drawing and as directed by Engineer in Charge with all necessary aluminium sections including necessary fixtures and fastening with 5 milimetre thick clear float glass etc. complete. Fourth Floor

8.64

-

-

... More
Providing and fixing in position aluminium fixed window fully glazed of any size with Powder Coating as per detailed drawing and as directed by Engineer in Charge with all necessary aluminium sections including necessary fixtures and fastening with 5 milimetre thick clear float glass etc. complete. Fifth Floor

8.64

-

-

... More
Providing and fixing in position powder coated aluminium louvered windows ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 milimetre x 1.22 milimetre box type, 5 milimetre thick sheet glass louvers, of approved quality complete. Ground Floor

2.3

-

-

... More
Providing and fixing in position powder coated aluminium louvered windows ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 milimetre x 1.22 milimetre box type, 5 milimetre thick sheet glass louvers, of approved quality complete. First Floor

22.44

-

-

... More
Providing and fixing in position powder coated aluminium louvered windows ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 milimetre x 1.22 milimetre box type, 5 milimetre thick sheet glass louvers, of approved quality complete. Second Floor

21.36

-

-

... More
Providing and fixing in position powder coated aluminium louvered windows ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 milimetre x 1.22 milimetre box type, 5 milimetre thick sheet glass louvers, of approved quality complete. Third Floor

21.36

-

-

... More
Providing and fixing in position powder coated aluminium louvered windows ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 milimetre x 1.22 milimetre box type, 5 milimetre thick sheet glass louvers, of approved quality complete. Fourth Floor

21.36

-

-

... More
Providing and fixing in position powder coated aluminium louvered windows ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 milimetre x 1.22 milimetre box type, 5 milimetre thick sheet glass louvers, of approved quality complete. Fifth Floor

13.8

-

-

... More
Providing and fixing in position (as per 1868:1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 milimetre at weight 0.637 kilogram per running metre with window frame bottom track section 92 x 31.75 x 1.30 milimetre at weight 1.070 kilogram per running metre. Top and side track section 92 x 31.75 x 1.30 milimetre at weight 0.933 kilogram per running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 milimetre at weight 0.417 kilogram per running metre Inter locking section 40 x 18 x 1.10 milimetre at weight 0.469 kilogram per running metre and handle and top section 40 x 18 x 1.25 milimetre at weight o.417 kilogram per running metre. As per detailed drawings and as directed by Engineer-in-charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 milimetre thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc. complete with powder coating without box. Ground Floor

73.71

-

-

... More
Providing and fixing in position (as per 1868:1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 milimetre at weight 0.637 kilogram per running metre with window frame bottom track section 92 x 31.75 x 1.30 milimetre at weight 1.070 kilogram per running metre. Top and side track section 92 x 31.75 x 1.30 milimetre at weight 0.933 kilogram per running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 milimetre at weight 0.417 kilogram per running metre Inter locking section 40 x 18 x 1.10 milimetre at weight 0.469 kilogram per running metre and handle and top section 40 x 18 x 1.25 milimetre at weight o.417 kilogram per running metre. As per detailed drawings and as directed by Engineer-in-charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 milimetre thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc. complete with powder coating without box. First Floor

217.13

-

-

... More
Providing and fixing in position (as per 1868:1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 milimetre at weight 0.637 kilogram per running metre with window frame bottom track section 92 x 31.75 x 1.30 milimetre at weight 1.070 kilogram per running metre. Top and side track section 92 x 31.75 x 1.30 milimetre at weight 0.933 kilogram per running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 milimetre at weight 0.417 kilogram per running metre Inter locking section 40 x 18 x 1.10 milimetre at weight 0.469 kilogram per running metre and handle and top section 40 x 18 x 1.25 milimetre at weight o.417 kilogram per running metre. As per detailed drawings and as directed by Engineer-in-charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 milimetre thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc. complete with powder coating without box. Second Floor

208.81

-

-

... More
Providing and fixing in position (as per 1868:1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 milimetre at weight 0.637 kilogram per running metre with window frame bottom track section 92 x 31.75 x 1.30 milimetre at weight 1.070 kilogram per running metre. Top and side track section 92 x 31.75 x 1.30 milimetre at weight 0.933 kilogram per running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 milimetre at weight 0.417 kilogram per running metre Inter locking section 40 x 18 x 1.10 milimetre at weight 0.469 kilogram per running metre and handle and top section 40 x 18 x 1.25 milimetre at weight o.417 kilogram per running metre. As per detailed drawings and as directed by Engineer-in-charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 milimetre thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc. complete with powder coating without box. Third Floor

204.49

-

-

... More
Providing and fixing in position (as per 1868:1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 milimetre at weight 0.637 kilogram per running metre with window frame bottom track section 92 x 31.75 x 1.30 milimetre at weight 1.070 kilogram per running metre. Top and side track section 92 x 31.75 x 1.30 milimetre at weight 0.933 kilogram per running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 milimetre at weight 0.417 kilogram per running metre Inter locking section 40 x 18 x 1.10 milimetre at weight 0.469 kilogram per running metre and handle and top section 40 x 18 x 1.25 milimetre at weight o.417 kilogram per running metre. As per detailed drawings and as directed by Engineer-in-charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 milimetre thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc. complete with powder coating without box. Fourth Floor

208.81

-

-

... More
Providing and fixing in position (as per 1868:1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 milimetre at weight 0.637 kilogram per running metre with window frame bottom track section 92 x 31.75 x 1.30 milimetre at weight 1.070 kilogram per running metre. Top and side track section 92 x 31.75 x 1.30 milimetre at weight 0.933 kilogram per running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 milimetre at weight 0.417 kilogram per running metre Inter locking section 40 x 18 x 1.10 milimetre at weight 0.469 kilogram per running metre and handle and top section 40 x 18 x 1.25 milimetre at weight o.417 kilogram per running metre. As per detailed drawings and as directed by Engineer-in-charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 milimetre thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc. complete with powder coating without box. Fifth Floor

129.86

-

-

... More
Providing and fixing mild steel grill work for windows, ventilators, 15 kilogram per square metre as per drawing including fixtures, necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting complete. Ground Floor

29.61

-

-

... More
Providing and fixing mild steel grill work for windows, ventilators, 15 kilogram per square metre as per drawing including fixtures, necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting complete. First Floor

157.11

-

-

... More
Providing and fixing mild steel grill work for windows, ventilators, 15 kilogram per square metre as per drawing including fixtures, necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting complete. Second Floor

148.33

-

-

... More
Providing and fixing mild steel grill work for windows, ventilators, 15 kilogram per square metre as per drawing including fixtures, necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting complete. Third Floor

148.33

-

-

... More
Providing and fixing mild steel grill work for windows, ventilators, 15 kilogram per square metre as per drawing including fixtures, necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting complete. Fourth Floor

148.33

-

-

... More
Providing and fixing mild steel grill work for windows, ventilators, 15 kilogram per square metre as per drawing including fixtures, necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting complete. Fifth Floor

97.7

-

-

... More
Providing and fixing solid core flush door shutter in single leaf 32 milimetre thick decorative type of exterior grade as per detailed drawings approved face veneers 3 milimetre thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. First Floor

65.04

-

-

... More
Providing and fixing solid core flush door shutter in single leaf 32 milimetre thick decorative type of exterior grade as per detailed drawings approved face veneers 3 milimetre thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. Second Floor

65.04

-

-

... More
Providing and fixing solid core flush door shutter in single leaf 32 milimetre thick decorative type of exterior grade as per detailed drawings approved face veneers 3 milimetre thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. Third Floor

65.04

-

-

... More
Providing and fixing solid core flush door shutter in single leaf 32 milimetre thick decorative type of exterior grade as per detailed drawings approved face veneers 3 milimetre thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. Fourth Floor

69.98

-

-

... More
Providing and fixing solid core flush door shutter in single leaf 32 milimetre thick decorative type of exterior grade as per detailed drawings approved face veneers 3 milimetre thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. Fifth Floor

59.34

-

-

... More
Providing and fixing 34 milimetre thick moulded door shutter consisting of solid core single leaf flush door of 30 milimetre thickness lipped with 15 milimetre (5 milimetre x 3) thick x 30 milimetre width on one style and top rail and 10 milimetre (5 milimetre x 2) thick x 30 milimetre width on other style and bottom rails. The inner panels laminated with 2 milimetre thick termite proof, water proof and fire resistant moulded Poly Venyl Chloride sheet with 2,4,6 design in different plain and /or prelim colours on one side after routing the moulded design on flush doors and 2 milimetre plain and /or pre lam Poly Venyl Chloride on other side using rubber adhesive on flush door and solvent cement adhesive on the Poly Venyl Chloride lipping etc. as per direction of Engineer in charge and manufacturers specification and drawing etc. complete. Ground Floor

21.96

-

-

... More
Providing and fixing 34 milimetre thick moulded door shutter consisting of solid core single leaf flush door of 30 milimetre thickness lipped with 15 milimetre (5 milimetre x 3) thick x 30 milimetre width on one style and top rail and 10 milimetre (5 milimetre x 2) thick x 30 milimetre width on other style and bottom rails. The inner panels laminated with 2 milimetre thick termite proof, water proof and fire resistant moulded Poly Venyl Chloride sheet with 2,4,6 design in different plain and /or prelim colours on one side after routing the moulded design on flush doors and 2 milimetre plain and /or pre lam Poly Venyl Chloride on other side using rubber adhesive on flush door and solvent cement adhesive on the Poly Venyl Chloride lipping etc. as per direction of Engineer in charge and manufacturers specification and drawing etc. complete. First Floor

39.48

-

-

... More
Providing and fixing 34 milimetre thick moulded door shutter consisting of solid core single leaf flush door of 30 milimetre thickness lipped with 15 milimetre (5 milimetre x 3) thick x 30 milimetre width on one style and top rail and 10 milimetre (5 milimetre x 2) thick x 30 milimetre width on other style and bottom rails. The inner panels laminated with 2 milimetre thick termite proof, water proof and fire resistant moulded Poly Venyl Chloride sheet with 2,4,6 design in different plain and /or prelim colours on one side after routing the moulded design on flush doors and 2 milimetre plain and /or pre lam Poly Venyl Chloride on other side using rubber adhesive on flush door and solvent cement adhesive on the Poly Venyl Chloride lipping etc. as per direction of Engineer in charge and manufacturers specification and drawing etc. complete. Second Floor

39.48

-

-

... More
Providing and fixing 34 milimetre thick moulded door shutter consisting of solid core single leaf flush door of 30 milimetre thickness lipped with 15 milimetre (5 milimetre x 3) thick x 30 milimetre width on one style and top rail and 10 milimetre (5 milimetre x 2) thick x 30 milimetre width on other style and bottom rails. The inner panels laminated with 2 milimetre thick termite proof, water proof and fire resistant moulded Poly Venyl Chloride sheet with 2,4,6 design in different plain and /or prelim colours on one side after routing the moulded design on flush doors and 2 milimetre plain and /or pre lam Poly Venyl Chloride on other side using rubber adhesive on flush door and solvent cement adhesive on the Poly Venyl Chloride lipping etc. as per direction of Engineer in charge and manufacturers specification and drawing etc. complete. Third Floor

39.48

-

-

... More
Providing and fixing 34 milimetre thick moulded door shutter consisting of solid core single leaf flush door of 30 milimetre thickness lipped with 15 milimetre (5 milimetre x 3) thick x 30 milimetre width on one style and top rail and 10 milimetre (5 milimetre x 2) thick x 30 milimetre width on other style and bottom rails. The inner panels laminated with 2 milimetre thick termite proof, water proof and fire resistant moulded Poly Venyl Chloride sheet with 2,4,6 design in different plain and /or prelim colours on one side after routing the moulded design on flush doors and 2 milimetre plain and /or pre lam Poly Venyl Chloride on other side using rubber adhesive on flush door and solvent cement adhesive on the Poly Venyl Chloride lipping etc. as per direction of Engineer in charge and manufacturers specification and drawing etc. complete. Fourth Floor

39.48

-

-

... More
Providing and fixing 34 milimetre thick moulded door shutter consisting of solid core single leaf flush door of 30 milimetre thickness lipped with 15 milimetre (5 milimetre x 3) thick x 30 milimetre width on one style and top rail and 10 milimetre (5 milimetre x 2) thick x 30 milimetre width on other style and bottom rails. The inner panels laminated with 2 milimetre thick termite proof, water proof and fire resistant moulded Poly Venyl Chloride sheet with 2,4,6 design in different plain and /or prelim colours on one side after routing the moulded design on flush doors and 2 milimetre plain and /or pre lam Poly Venyl Chloride on other side using rubber adhesive on flush door and solvent cement adhesive on the Poly Venyl Chloride lipping etc. as per direction of Engineer in charge and manufacturers specification and drawing etc. complete. Fifth Floor

24.68

-

-

... More
Providing and fixing fibre glass reinforced polyster door shutter 35 milimetre thick as per IS 14856 (2000) (reaffirmed 2006 ) without ventilator including chromium plated fixtures and fastening with chromium plated handles on both sides, complete. First Floor

67.68

-

-

... More
Providing and fixing fibre glass reinforced polyster door shutter 35 milimetre thick as per IS 14856 (2000) (reaffirmed 2006 ) without ventilator including chromium plated fixtures and fastening with chromium plated handles on both sides, complete. Second Floor

67.68

-

-

... More
Providing and fixing fibre glass reinforced polyster door shutter 35 milimetre thick as per IS 14856 (2000) (reaffirmed 2006 ) without ventilator including chromium plated fixtures and fastening with chromium plated handles on both sides, complete. Third Floor

67.68

-

-

... More
Providing and fixing fibre glass reinforced polyster door shutter 35 milimetre thick as per IS 14856 (2000) (reaffirmed 2006 ) without ventilator including chromium plated fixtures and fastening with chromium plated handles on both sides, complete. Fourth Floor

67.68

-

-

... More
Providing and fixing fibre glass reinforced polyster door shutter 35 milimetre thick as per IS 14856 (2000) (reaffirmed 2006 ) without ventilator including chromium plated fixtures and fastening with chromium plated handles on both sides, complete. Fifth Floor

37.6

-

-

... More
Providing and fixing white wash basin with half pedestal of size 515 milimetre x 615 milimetre x 460 milimetre including pillar cock auto-closing system CP angular stop cock long thread of approved make continental including S.S. bottle trap of necessary pipe connection upto the outside face of the wall. First Floor

32

-

-

... More
Providing and fixing white wash basin with half pedestal of size 515 milimetre x 615 milimetre x 460 milimetre including pillar cock auto-closing system CP angular stop cock long thread of approved make continental including S.S. bottle trap of necessary pipe connection upto the outside face of the wall. Second Floor

32

-

-

... More
Providing and fixing white wash basin with half pedestal of size 515 milimetre x 615 milimetre x 460 milimetre including pillar cock auto-closing system CP angular stop cock long thread of approved make continental including S.S. bottle trap of necessary pipe connection upto the outside face of the wall. Third Floor

32

-

-

... More
Providing and fixing white wash basin with half pedestal of size 515 milimetre x 615 milimetre x 460 milimetre including pillar cock auto-closing system CP angular stop cock long thread of approved make continental including S.S. bottle trap of necessary pipe connection upto the outside face of the wall. Fourth Floor

32

-

-

... More
Providing and fixing white wash basin with half pedestal of size 515 milimetre x 615 milimetre x 460 milimetre including pillar cock auto-closing system CP angular stop cock long thread of approved make continental including S.S. bottle trap of necessary pipe connection upto the outside face of the wall. Fifth Floor

20

-

-

... More
Providing and fixing Crome Plated BIB cock with wall flange of approved make including necessary sockets/union nut etc. complete. First Floor

8

-

-

... More
Providing and fixing Crome Plated BIB cock with wall flange of approved make including necessary sockets/union nut etc. complete. Second Floor

8

-

-

... More
Providing and fixing Crome Plated BIB cock with wall flange of approved make including necessary sockets/union nut etc. complete. Third Floor

8

-

-

... More
Providing and fixing Crome Plated BIB cock with wall flange of approved make including necessary sockets/union nut etc. complete. Fourth Floor

8

-

-

... More
Providing and laying in situ/ Ready Mix cement concrete Mix-20 of trap/ granite/quartzite/ gneiss metal for Reinforced Cement Concrete work in foundations like raft, strip foundations, grillage and footings of Reinforced Cement Concrete columns and steel stanchions etc. including bailing out water, formwork, laying/ pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided, (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade).

211.84

-

-

... More
Providing and laying cast in situ/ Ready Mix cement concrete Mix-20 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete columns as per detailed designs and drawing or as directed including centering, formwork, cover blocks, laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade).

134.29

-

-

... More
Providing and laying Cast in situ/ Ready Mix cement concrete Mix-20 of trap/ granite/quartzite/ gneiss metal for Reinforced Cement Concrete Beams and Lintels as per detailed designs and drawings or as directed including centering, formwork, cover blocks, laying/ pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel), with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade).

109.7

-

-

... More
Providing and laying Cast in situ/ Ready Mix cement concrete Mix-20 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Slabs and Landings as per detailed designs and drawings including centering, formwork, cover blocks, laying/ pumping, compactionfinishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade).

3.89

-

-

... More
Providing and fixing 50 milimetre diameter medium class Galvanised Iron pipe gate with wicket gate of approved drawing with all fixtures and fittings in two leaves with strong hold fast embedded in Cement Concrete block at top and bottom with locking arrangement including cutting, bending, making holes and with one coat of primer complete.

49.6

-

-

... More
Excavation for roadway in earth soil of all sorts, sand, gravel or soft murum including dressing section to the required grade camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50 metre and spreading for embankment or stacking as directed.

3418.17

-

-

... More
Providing earth work in embankment with approved materials obtained from other sources upto lead of 50 metre including all lifts, laying in layers of 20 centimetre to 30 centimetre thickness breaking clods, dressing to the required lines, curves, grades and section, watering and compaction with vibratory roller with V-Sat attachment to achieve not less than 97% of standard proctor density etc. complete (Material obtained from Other sources).

3418.17

-

-

... More
Supplying hard murum at the road site including conveying and stacking complete.

4050.17

-

-

... More
Compacting the hard murum side widths including laying in layers on each side with power roller including artificial watering complete.

7754.4

-

-

... More
Construction of granular sub-base by Plant Mix Method by providing close graded Material, mixing in a mechanical mix plant at Optimum Moisture Content, carriage of mixed Material to work site,spreading in uniform layers with Motor Grader/ Paver on prepared surface and compacting with vibratory power roller to achieve the desired density complete as per clause 401.For Grading I Material.

502.58

-

-

... More
Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate (Natural Sand/ VSI grade finely washed Crushed Sand) conforming to IS: 383, the size of coarse aggregate not exceeding 25 milimetre, cement content not to be less than 150 kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor/ by suitable means as approved by Engineer-in-charge, compacting with vibratory roller, finishing and curing including preparation of sub-grade surface if required etc. complete.

502.58

-

-

... More
Providing and fixing in position TMT FE-500,32 milimetre diameter dowel bars precoated with anticorrosive epoxy paint 60 centimetre long and at 30.00 centimetre center to center wherever directed including handling, straightening, necessary cutting supported by HYSD chairs with proper alignment by using properly designed assembly of Bulkheads lubricating half length with bituminous paint as directed etc. complete.

1060

-

-

... More
Providing and fixing in position TMT FE-500, tie bars precoated with anticorrosive epoxy paint of 12 milimetre diameter 70 centimetre long and at 30.00 centimetre center to center and wherever directed including handling, straightening wrapping with paper of approved quality for half length, necessary cutting, handling, straightening, supported by assembly of HYSD chairs with proper alignment etc. complete.

1750

-

-

... More
Providing and laying in situ cement concrete M-30 with tremix treatment for 200 milimetre thickness for Concrete Road including laying plastic sheet of 125 micron with groove cutting of 4 milimetre wide and 20 milimetre deep, with necessary refilling with Refilling with Polysulfide Sealent (pouring Grade) conforming to BS:5212-1989 into sawed groove widened at top for sealent reservoir of specified size and shape as per detailed drawing including fixing polyethylene foam backer road of required diameter (excluding reinforcement) with course and fine agreegates using VSI quality artificial sand etc. complete.

617.44

-

-

... More
Providing and applying Cold plastic paint two component rolled on surfacing material solvent free,high build two pack seamless,tough,skid resistant,material with has property of attaining 2.00 milimetre thickness in single coat application white(or as required colour) based on glass and colour retaining acralic cross linking resin system for coloured road surfacing including surface cleaning and cost of all material etc. complete. (All inclusive on bitumen or concrete surface) work shall carried out as per IRC 35-2015 clause 2.2).

151.15

-

-

... More
Providing and casting in situ or precast tapering Reinforced Cement Concrete Mix-20 Barrier type Kerb with gutter (as per IRC:86-1983) embedded 125 milimetre below ground level over Mix-10 Plain Cement Concrete finished neatly with Cement Mortar 1:2, setting the same in Cement Mortar 1:2, including the required excavation in any strata and removing the excavated stuff any where in city and redoing the surface as specified and directed by Engineering In-charge. Using Concrete Batching and Mixing Plant.

1671.52

-

-

... More
Providing and laying in situ cement concrete M30 with tremix treatment for 200 millimeter thickness for flooring with groove cutting of 4 millimeter wide and 20 millimeter deep with necessary refilling with bitumen complete.

480

-

-

... More
Providing and fixing colour coated Zincalume ( R ) AZ150 ( min 150 gms/sq.mt. total on each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% aluminium 43.4% zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyester paint coat ( with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950-1050 mm effective cover width and nominal 25-30 mm deep ribs with subtle square fluting in the five pan at nominal 180-250 mm center-to-center. The end rib shall be designed for anti-capillary groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete. (weight of profile 4.52 kg/sqm)

480

-

-

... More
GARDEN SOIL : Supplying on site garden soil well sieved 90% to pass through I.S. sieve of 10 mm sixe free from stones rubbish like dried grass mots and other such materials. The soil should be fresh from qarry. The colour of the soil generally be red. The soil will be measured b measuring box .(Farma) (Item includes Royalty charges ., Transporting, loading unloading etc.) lead charges for 20 k.m. is considered

180

-

-

... More
FARM YARD MANURE :Supplying on site well decayed, well dried , well powered, without clods and free from stones, dried grass and other rubbish material . The colour fo manure generally be black. The manure will be measured by measuring box. (Fanna)(Item includes Transporting , loading unloading etc.) lead charges for 20 k.m. is considered

180

-

-

... More
Preparing Lawn (30 cms.Depth) Excavating the ground to a required depth of 30 cms. Removing & conveying unwanted stuff to a required distance as directed. Filling fresh garden soil/silt & manure in excavated area in 3:1 proportion to a height of 30cms. Mixing garden soil and manure thoroughly, well, leveling, watering on previous night. Planting required variety of lawn grass as directed and maintaining till well established by watering, weeding, clipping, rolling etc. complete (R.A.No.1)

600

-

-

... More
Providing and installing Bio Digester unit based on DRDO technology made of fibre reinforced plastic (FRP) having composition and following technical specifications and including necessary pipe and accessories up to 3 meter length, excluding the necessary excavation for installing the bio digester. Percentage of fibre glass (glass content in fibre glass should be minimum 30 percent): -33.33 percent Percentage of polyester resin: - 66.67 percent, Water absorption (as per ASTM):-0.30 percent, Flammability as per ASTM, Tensile strength:-115 MPA Specific Gravity at 25 degree centigrade 1.45, Izod impact strength:-65KJ/M2, Heat defection/distort temperature:-65deg C, Corrosion resistance (Non Corrosive) fitted with Inlet pipe size rigid PVC: -100mm Outlet pipe size rigid PVC:-80mm, Gas outlet rigid PVC with Valve: 20mm, Bacteria immobilization PVC mattes (on all partition) With DRDO TOT licensee and latest batch certificate(month & year of supply) and capacity as below Up to 200 user size (4mx2.0mx1.25m), Capacity of Biodigester:-10000 liters, Area of top, bottom and side walls: - 31.00 sq.m, Area of partition walls: 10.00sq.m, Total weight of FRP: - 462.60 kg, Bacteria inoculums quantity: - 3400 liters, Minimum thickness of side walls / top and bottom: 7mm, Number of inside partitions: - 4, Minimum thickness of partition wall: 4mm

1

-

-

... More
Providing and fixing reinforced cement concrete Heavy duty (160 kilogram) cover of size 60 centimeter x 45 centimeter with frame over inspection chamber complete.

4

-

-

... More
SUB- WORK - NO-1 Providing Internal Electrification to proposed Upgradation of 30 Bedded to 100 beded Sub District Hospital and Staff Residential Buildingss at Mangalwedha, Tal.- Mangalwedha Dist.- Solapur. Supplying and erecting HMS PVC conduit FRLS grade 20 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.

5174

-

-

... More
Supplying and laying HMS PVC conduit FRLS grade 20 mm dia. With necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.

14630

-

-

... More
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.

2446

-

-

... More
Supplying and laying HMS PVC conduit FRLS grade 25 mm dia. With necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.

7142

-

-

... More
Supplying and erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW

10523

-

-

... More
Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW

12556

-

-

... More
Supplying and erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW

19789

-

-

... More
Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW

19789

-

-

... More
Supplying and erecting mains with 1x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW

6790

-

-

... More
Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW

6790

-

-

... More
Supplying and erecting mains with 1x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW

2785

-

-

... More
Supplying and erecting mains with 2x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW

2785

-

-

... More
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.

2799

-

-

... More
Supplying and erecting modular type switch one way 16 / 20 A, duly erected on provided plate and box with wiring connections complete with neon indicator.

1367

-

-

... More
Supplying and erecting modular type switch 16 / 20 A with indicator, duly erected on provided plate and box with wiring connections complete. (for Split AC)

38

-

-

... More
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete

2799

-

-

... More
Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.

1404

-

-

... More
Supplying and erecting modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connections complete.

113

-

-

... More
Supplying and erecting modular type computer Jack RJ45 with safety shutter, duly erected on provided plate and box with wiring connections complete.

171

-

-

... More
Supplying and erecting modular type T.V. socket single outlet, duly erected on provided plate and box with wiring connections complete.

131

-

-

... More
Supplying and erecting modular type bell-push 6A / 10A duly erected on provided plate and box with wiring connections complete.

193

-

-

... More
Supplying and erecting luminous / modular type call bell indicator with plastic body, heavy duty coil and indicator lamp working on 230V A.C. Supply with resetting arrangement complete erected on double wooden/ sunmica board.

193

-

-

... More
Supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete.

1063

-

-

... More
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.

786

-

-

... More
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.

299

-

-

... More
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.

842

-

-

... More
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 4 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.

54

-

-

... More
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.

1222

-

-

... More
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.

167

-

-

... More
Wiring for plug on board with Switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WGPW/CW

1120

-

-

... More
Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/CW

1643

-

-

... More
Point wiring for ceiling fan concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/CW

379

-

-

... More
Point wiring for light/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/HW

1640

-

-

... More
Point wiring for ceiling fan (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/HW

684

-

-

... More
Secondary point wiring for additional light/ bell point in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire with required accessories as per specification No: WG-PW/SW

691

-

-

... More
Supplying and erecting LED square / circular Max. 14 W down lighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 1500 Lumens, min. efficacy of 110 lumen/W, CRI80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD10%, p.f. 0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.

552

-

-

... More
Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD10%, p.f. 0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.

68

-

-

... More
Supplying and erecting LED square / circular Max. 25 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2750 Lumens, min. efficacy of 110 lumen/W, CRI80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD10%, p.f. 0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.

399

-

-

... More
Supplying and erecting LED Panel Light(600mm X 600mm) Max. 30 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min. 3600 Lumens, min. efficacy of 120 lumen/W, CRI80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD10%, p.f. 0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.

354

-

-

... More
Supplying and erecting LED Panel Light(600mm X 600mm) Max. 35 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min 4200 Lumens, min. efficacy of 120 lumen/W, CRI80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD10%, p.f. 0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.

219

-

-

... More
Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens , min. efficacy of 100 lumen/W, CRI80, CCT upto 6000K, Beam Angle of 110 deg., Ripple5%, THD10%, p.f. 0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty.

605

-

-

... More
Supplying and erecting anodized aluminium corridor / passage / mirror light LED fitting (2 feet) Max. 12W with high transitivity diffuser with min. system lumens output of 1200 lumens, min. efficacy of 100 lumen/W, CRI80, CCT upto 6000K, Beam Angle of 110 deg., Ripple5%, THD10%, p.f. 0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver with end caps on provided PVC Block / wooden board with 3 years warranty.

305

-

-

... More
Supplying & erecting 10-12W, 230V integral type LED Lamp suitable for B-22 / E-27 base.

443

-

-

... More
Supplying & erecting inverter LED batten 20W tube light fitting with polycarbonate housing, heat sink, integrated HF electronic driver, Min. 2600 mAh Lithium ion Battery with charging time of 8-10 Hours and backup time of Min. 3 hrs. with minimum 25% of initial Watts having luminous efficacy of 100 lumen/watt, CRI80, CCT of 6500K and THD=20% having useful life of minimum 25000 hrs. with overheating protection with 2 years warranty.

367

-

-

... More
Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI80, CCT upto 6500K, Beam Angle of 120 deg., THD10%, p.f. 0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty.

281

-

-

... More
Supplying LED concealed type foot / step light with aluminium body for indoor/outdoor application suitable for 4W-6W LED including driver and erecting by making necessary arrangement / recess in wall to make it flush with surface with 1 year warranty.

12

-

-

... More
Supplying and erecting ding dong / electronic musical type call bell with heavy duty coil suitable to operate on 230V A.C. supply erected on polished double wooden block/sunmica block of suitable size.

157

-

-

... More
Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 300mm. 1400 RPM rust proof body & blades, wire mesh, duly erected, complete.

209

-

-

... More
Supplying and erecting bracket fan 400 mm. sweep A. C. 230 volts 50 cycles 1350 RPM. Oscillating type, plastic or metal blades chrome plated guard with speed regulator and moisture proof treatment to winding and with ‘E’ class insulation.

10

-

-

... More
Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of 28W having service ratio (CMM/W) of Min. 8 , PF0.9, THD10% without IR remote control/compatible speed regulator, Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF

1059

-

-

... More
Supplying and erecting fan hook box of 10 mm M.S. round bar bounded to the R.C.C. bars upto 50 mm length each side and pierced through a 16 S.W.G. thick aluminium/M.S. Bowl 100 mm dia. or equivalent square size and having depth upto 75 mm complete erected with duly painted by one coat of red oxide paint and two coats of paint erected in position and without any leakage of slurry of cement concrete on either side of the box and positioned to the bottom level of the slab.

1059

-

-

... More
Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire.

1059

-

-

... More
Supplying and erecting storage type water heater 50 litres capacity having standing loss 0.675 kWh/24hour/45°C, high impact resistance engineering plastic body with anti corrosive high grade steel inner tank heating element having hard water & corrosion protection, with minimum 3 safety protections (i.e. thermostat & thermal cut-out, function valve) with total pressure 8 bar withstanding capacity duly tested and marking sr. no. and date of erection complete. specification no.AP-WH/STWH

23

-

-

... More
Supplying and erecting storage type water heater 25 litres capacity having standing loss 0.511kWh/24hour/45°C, high impact resistance engineering plastic body with anti corrosive high grade steel inner tank, heating element having hard water & corrosion protection, with minimum 3 safety protections (i.e. thermostat & thermal function cut-out, valve) with total pressure 8 bar withstanding capacity duly tested and marking sr. no. and date of erection complete. specification no. AP-WH/STWH

112

-

-

... More
Supplying, erecting, testing and commissioning self contained water cooler 230/250V 50Hz nominal cooling capacity of 80 litres per hour and storage capacity 120 litres with partially stainless steel body as per specification no. AP-WCR/WC

6

-

-

... More
Supplying and erecting ultra violet water purifier with softener for safe drinking water consisting of UV germicidal tube of 8W capacity, choke made of copper wire, two indicator lamps, dual function cartridge with output of purified water 1 litre/min with activated carbon filter and softener operating on 230V, single phase A.C. supply with UV fail & filter change indication system.

6

-

-

... More
Supplying, erecting, testing and commissioning of single phase input & 1 phase output 1 kVA capacity online pure sine wave UPS, with backup time of Two hrs. PWM & IGBT based, with 0.8 to unity output pf complete with all protections as per specification no. AP-UPS

6

-

-

... More
Supplying, erecting, testing and commissioning of 10kVA capacity online pure sine wave, with backup time of 1 hrs. PWM & IGBT based UPS with 0.9 to unity output pf, 3 phase input & 3 phase output complete with all protections as per specification no. AP-UPS

5

-

-

... More
Supplying and erecting 12 V/65Ah SMF battery with battery terminal wire, duly charged complete with 24 months warranty complete

118

-

-

... More
Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

1221

-

-

... More
Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

748

-

-

... More
Supplying, erecting & commissioning 2 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB

74

-

-

... More
Supplying, erecting & marking DPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

12

-

-

... More
Supplying, erecting & marking TPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

63

-

-

... More
Supplying, erecting & marking FPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

83

-

-

... More
Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

18

-

-

... More
Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 2 ways (2 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB

8

-

-

... More
Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB

3

-

-

... More
Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB

72

-

-

... More
Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 4 ways/phase (12 poles), with door, 1.2mm thickness, surface/flush mounted, IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB

72

-

-

... More
Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 4 ways /12 Poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB

11

-

-

... More
Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 8 ways /24 poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB

17

-

-

... More
Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame.

4

-

-

... More
Supplying, erecting & terminating XL-HFFR insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

250

-

-

... More
Supplying, erecting & terminating XL-HFFR insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

1494

-

-

... More
Supplying, erecting & terminating XL-HFFR insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

996

-

-

... More
Supplying, erecting & terminating XL-HFFR insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

630

-

-

... More
Supplying, erecting & terminating XL-HFFR insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

30

-

-

... More
Supplying, erecting & terminating XL-HFFR insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 70 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

70

-

-

... More
Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware.

445

-

-

... More
Providing & erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 150 mm width & 20 mm height complete with necessary hardware.

445

-

-

... More
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. Cover complete with all materials, testing & recording the results as per specification no.EA-EP

16

-

-

... More
Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with insulating and non-corrosive bond with required joints As per specification no. EA-EP.

866

-

-

... More
Supplying & erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation complete.

12

-

-

... More
Supplying & erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW

3450

-

-

... More
Supplying & erecting 20 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW

970

-

-

... More
Supplying & erecting 100 pair, 0.5mm dia, jelly filled unarmoured telephone copper cable with poly-al laminate moisture barrier, laid in provided PVC casing capping/ conduit as per specification No. WG-TW

70

-

-

... More
Supplying, erecting & commissioning MDF Box 100x100 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW

1

-

-

... More
Supplying, erecting & commissioning 20 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TW

13

-

-

... More
Supplying and installing, testing & commissioning of digital (hybrid) type EPABX of 6 x 32 extensions suitable upto 96 extensions complete. With additional 16 extension card

1

-

-

... More
Supplying, installing, testing & commissioning push button telephone instrument desk top unit as per specification complete

113

-

-

... More
Supplying, installing, testing & commissioning IP telephone instrument as per specification complete.

1

-

-

... More
Supplying and installing cat-6 LSZH cable suitable for networking as per specification no. WG-COC/NC

4275

-

-

... More
Supplying and installing cat-6 armoured cable with ECCS tape suitable for networking as per specification No. WG-COC/NC

90

-

-

... More
Supplying and fixing 1 m UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC

181

-

-

... More
Supplying, fixing, and configuring 24 ports with 4 (SFP+) port, ethernet managed switch with web view/CLI, 6KV surge protection on ethernet port and console port for management in provided rack as per specification no. WGNWC/ GBS

9

-

-

... More
Supplying, fixing, and configuring broadband ADSL router with all accessories, on provided rack or as directed as per specification No. WG-NWC/ADSL

20

-

-

... More
Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP

9

-

-

... More
Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x600x367 mm) as per specification No. WG-NAS/RAK

8

-

-

... More
Supplying and fixing 9U wall mount rack (Dimension-DxWxH – 500x600x500 mm) as per specification No. WG-NAS/RAK

1

-

-

... More
Supplying and fixing dual-band manageable wireless 3x3 Mesh Router, high performance, 802.11 n/ac unified, concurrent access point with POE in networking as per specification no. WG-NAS/LAP2

1

-

-

... More
SUB- WORK - NO-2 Providing External Electrification Works DTC, DG set works, Solar Hot Water System, MSEDCL Provison to proposed Upgradation of 30 Bedded to 100 beded Sub District Hospital and Staff Residential Buildingss at Mangalwedha, Tal.- Mangalwedha Dist.- Solapur. Supplying, erecting, testing & commissioning 11kV, 630A, 21kA/3sec, 5 way outdoor, extensible motorised SCADA compatible RMU, internal arc tested consisting of 2 nos. feeder with 2 LBS and 3 nos. feeder with 3 VCB compliant to IEC 62271 -100, 200 and 102, as per specification no. SW-HTS/RMU SCADA

1

-

-

... More
Supplying and erecting triple pole mini feeder pillar with 500V, 300A FPMCCB as incomer and 3 outgoing circuits with HRC fuse base and cartridge of 100A with aluminium bus bar erected in 14 SWG CRCA sheet box with supporting angles, self locks, gasket having IP54,IK10 protection and slanting top to be erected on provided foundation as per specification no. SW-SWR/MFP

1

-

-

... More
Supplying, erecting, testing and commissioning 11KV HT metering cubical (compact / vertical type) approved by MSEDCL / licensee fabricated with 2 mm (14 SWG) M.S. sheets with supporting angle, painted with powder coating / epoxy paint of required shade, copper bus bar size 25 x 6 mm, heavy duty mechanical lock, with counter meter for measuring no of times the opening of meter door, top side cover (CT, PT cover) interlock with meter door, epoxy casted 3 nos. CT having required ratio between 10/5A to 50/5A, VA10 or 15, Class 0.5S, epoxy casted 3 nos. PT having ratio 11000/V3/110/V3 VA 50, Class 0.5 suitable for provided trivector meter, and provision for incoming and outgoing cables complete duly tested by licensee with necessary test certificates and erected on provided plinth/ cc foundation.

1

-

-

... More
Supplying and erecting 125 kVAr, 440 V 3 phase, 50 Hz., Contactor Logic & Intelligent Relay micro APFC passive filter panel, consisting of suitable steps of APP/MPP type capacitor units with Detuned (harmonic filter) reactors of suitable rating , APFC panel shall be compliance to IEC 61439 and power quality IEC 61921 standard as per specification no CP-ED/APFC

1

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 300 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL (for Transformer 2x25m & DG Set 2x25m to MLTP, MLTP to Hosp Dist. Panel 2x145m, MLTP to HVAC Panel 150m, MLTP to Med Equip Panel 150m, MLTP to FP1 252m, MLTP to Res Qtr FP 275m)

390

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 185 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL (for Hosp. FP2 & ResQtr Bldg B)

120

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 95 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL (for APFC panel)

20

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 50 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL (for ResQtr Bldg A&C)

100

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL ( for Pump Room, Kitchen & Laundry Bldg)

375

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL (STP )

215

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL (Security Cabin)

100

-

-

... More
Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 11 kV(E), 3 x 95 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT (Res Qtr) (2 Run 1W+1S)

50

-

-

... More
Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 11 kV(E), 3 x 120 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT (Hospital) (2 Run 1W+1S)

80

-

-

... More
Providing and erecting Heat shrinkable indoor termination kit for 11 kV ( E ) XLPE HT cable 3x up to 95 sq. mm. with necessary material as per specification no. CB-JT/HT (at RMU)(1W+1S)

2

-

-

... More
Providing and erecting Heat shrinkable out door termination kit for 11 kV ( E ) XLPE HT cable 3 x up to 95 sq. mm. with necessary material as per specification No. CB-JT/HT (at X'mer)(1W+1S)

2

-

-

... More
Providing and erecting Heat shrinkable indoor termination kit for 11 kV ( E ) XLPE HT cable 3x up to 120 sq. mm. with necessary material as per specification no. CB-JT/HT (at RMU-2, KIOSIK-2, X'mer-1)(1W+1S)

10

-

-

... More
Providing and erecting Heat shrinkable outdoor termination kit for 11 kV ( E ) XLPE HT cable 3x120 to 185 sq. mm. with necessary material as per specification no. CB-JT/HT (at Exsting feeder)(1W+1S)

2

-

-

... More
Supplying & laying (including excavation) reinforced cement concrete pipe of IS 458:2003 NP-2 class of 250 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. (for Hospital & ResQtr Supply)

417

-

-

... More
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.

553

-

-

... More
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 90 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.

175

-

-

... More
Supplying & erecting end pole D. P. Structure for 11/0.415 kV, 200 kVA Transformer with R.S.J. Pole 2 Nos. of size 100mm x 116 mm x 11 m Long with suitable Distribution Box of C.R.C.A. Sheet 16 SWG with 4 Pole MCCB 400 Amps as incomer & 6 Nos.200 Amps Kitkat / MCCB for out going circuits. Transformer D.P. Structure includes the A. B. Switch 200 Amps, D.O. fuse Set & L.A. Set. 2 Nos. Top channel of size 100 mmx 50 mm for erection of A.B. Switch & 2 Nos. Base channel of size 100 mm x 50 x mm for erecting Transformer. Channel of size 75 x40 mm for erecting D.O. Fuse Set, L.A., A.B. Switch handle etc. Angle of size 50 x 50 x6 mm for erecting Distribution Box , Transformer Belt etc.as per drawing (min. 124 Kg. iron work) with necessary clamps, Nut-bolts. V cross arm, top clip, insulators etc. complete with caution board & barbed wire. D.P. Structure shall be erected in c.c. foundation complete. (Res. Qtr)

1

-

-

... More
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no.EA-EP

21

-

-

... More
Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results as per specification no. EA-EP

15

-

-

... More
Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with insulating and non-corrosive bond with required joints As per specification no. EA-EP.

86

-

-

... More
Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EAEP.

43

-

-

... More
Supplying, installing, testing & commissioning 3 phase, 11/0.433 kV, 50 Hz., 200 kVA, Mineral oil immersed and naturally cooled outdoor type, copper wound Non-sealed transformer delta/star connected with additional neutral brought out on load side, temperature rise should not exceed 45℃ by thermometer in oil and 50 ℃ by the resistance method in winding at full load rating, using type A winding insulation (kraft paper) with HV tapping (with off load tap changer)off load +2.5 to -5 in steps of 2.5%, having 4 number of tap positions, with standard accessories complete with test certificate with losses below 780 Watts at 50% load, 2300 Watts at 100% load as per IS:1180 (part 1) : 2014 , with necessary permissions of Electrical Inspector, as per specification no SS- TRNSL.

1

-

-

... More
Supplying, installing, testing & commissioning 3 phase, 11/0.433 kV, 50 Hz., 500 kVA, Mineral oil immersed and naturally cooled indoor type, Copper wound Non-sealed transformer delta/star connected with additional neutral brought out on load side, temperature rise should not exceed 45℃ by thermometer in oil and 50℃ by the resistance method in winding at full load rating, using type A winding insulation (kraft paper) with HV tapping (with off load tap changer) off load +5 to -10 in steps of 2.5%, having 7 number of tap positions with standard accessories complete with test certificate with losses below 1225 Watts at 50% load, 3450 Watts at 100% load as per IS:1180 (part 1) : 2014 with necessary permissions of Electrical Inspector, as per specification no SS- TRNSL.

1

-

-

... More
Supplying and erecting fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work erected in CC foundation and painted complete as per specification no SS-AS/FSG ( for Each DTC 10 nos)

10

-

-

... More
Supplying and erecting fencing of section having size 2450 mm in height from ground level and 600 mm width with angle iron frame work erected in CC foundation and painted complete as per specification no SS-AS/FSG ( for Each DTC 3 nos)

3

-

-

... More
Supplying and erecting 50 x 50 x 6 mm angle iron as corner support 2m long fixed at the middle of the fencing frame and the other side inclined at 30 degree angle, in cement concrete foundation of 15 x 15 x 40 cm complete duly painted with one coat of red oxide and two coats aluminium paint complete.

4

-

-

... More
Supplying and erecting double leaf hinged door each 1500 mm in width x 1850 mm in height using B class, GI pipe with angle iron supports, chain link wire mesh (jali) complete supported on channel iron, erected in foundation, and painted complete as per specification no SS-AS/DLD

1

-

-

... More
Providing pair of duly tested rubber hand gloves as per IS :47705 suitable for working up to 22 kV supply complete.

1

-

-

... More
Supplying and fixing PVC synthetic elastomer electrically insulating mat with class B insulation conforming to IS: 15652 – 2006 having 2.5 mm thickness up to 11 kV

2

-

-

... More
Supplying and spreading stone metal 25 mm size for 100 mm depth above the ground level complete

16

-

-

... More
Making Transformer plinth (1.5 x 1.5 x 1.5)m in size with necessary excavation in ground with 150mm thick M-10 PCC at the bottom and top and 250mm thick, burnt brick wall constructed at periphery and remaining hollow portion shall be filled with 40mm hard broken aggregate. External surface duly plastered by 12mm thick including watering etc. complete.

1

-

-

... More
Making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (for Feeder Piller- 3 Nos 300x300x500mm, RMU - 1250x 1250 x 800 mm , Koisik 1250x 1250 x 800 mm & DG Set 2Nos 1950x 4650 x 500 mm).

13.36

-

-

... More
Excavating soft murum / soft soil road by chiselling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site good complete. (for Feeder Piller- 3 Nos 300x300x300mm, RMU - 1250x 1250 x 500 mm , Koisik 1250x 1250 x 500 mm & DG Set 2Nos 1950x 4650 x 350 mm).

9.48

-

-

... More
SITC of Main Panel,The panel shall be comprising of following & IEC 61439, Panel should be fully compartmentallised, wall mounted with M.S. Channel dully painted, fabricated of 14/16swg CRCA sheets completely derusted, chemically treated and powder coated with approved shade, ON - Off Indicating LED lamp, locking arrangements, withdual source intelligent flush mounted panel meter three phase four wire (IPM) 415V CT/ PT site programmable class I flush mounted (96 x 96mm) meter with voltage, current, frequency, power factor , ON hrs, kWh, EB and DG set metering and LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden, The Panel is compitable with Provided Synchronisation Panel for 2 Nos 200 KVA DG Set, with follwing Incoming and Out going :-- Main I/O 630 Amp ACB. 650V, rated at 50º C without deration, 12kV Impulse, 4 pole (100% Neutral Protection), 50 kA (Ics=Icu=Icw for 1s), with Micro-processer based LCD display release with LSIG and temperature rise protection & with 4 C/O contacts for On-Off-Trip indication, min. 5 event and trip history on breaker display DG I/O 630 Amp ACB. 650V, rated at 50º C without deration, 12kV Impulse, 4 pole (100% Neutral Protection), 50 kA (Ics=Icu=Icw for 1s), with Micro-processer based LCD display release with LSIG and temperature rise protection & with 4 C/O contacts for On-Off-Trip indication, min. 5 event and trip history on breaker display Bus bar chamber TPN & E with aluminium bars 630 A. Outgoing- 400ATP MCCB -4 Nos. 250ATP MCCB -1 No. 200ATP MCCB -2 No 100ATP MCCB -1 No 40- 63A TP MCB C series -2 Nos. 6-32A TP MCB C Series- 4 Nos

1

-

-

... More
SITC of DISTRIBUTION Floor Panel,The panel shall be comprising of following & IEC 61439, Panel should be fully compartmentallised, wall mounted with M.S. Channel dully painted, fabricated of 14/16swg CRCA sheets completely derusted, chemically treated and powder coated with approved shade, ON - Off Indicating LED lamp, locking arrangements, withdual source intelligent flush mounted panel meter three phase four wire (IPM) 415V CT/ PT site programmable class I flush mounted (96 x 96mm) meter with voltage, current, frequency, power factor , ON hrs, kWh and LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden as per SLD having following items:- Main I/O 400 Amp FP MCCB. Bus bar chamber TPN & E with aluminium bars Outgoing- 200A TP MCCB- 3 N0s. 100A TP MCCB- 1 N0s., 63A TP MCB-4 Nos, 32A TP MCB -4.Nos (RA Sheet Attached)

1

-

-

... More
SITC of Floor Panel,The panel shall be comprising of following & IEC 61439, Panel should be fully compartmentallised, wall mounted with M.S. Channel dully painted, fabricated of 14/16swg CRCA sheets completely derusted, chemically treated and powder coated with approved shade, ON - Off Indicating LED lamp, locking arrangements, withdual source intelligent flush mounted panel meter three phase four wire (IPM) 415V CT/ PT site programmable class I flush mounted (96 x 96mm) meter with voltage, current, frequency, power factor , ON hrs, kWh and LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden as per SLD having following items:- Main I/O 200 Amp FP MCCB. Bus bar chamber TPN & E with aluminium bars Outgoing- 63A FP MCB-6 Nos, 32A FP MCB -8.Nos, 25/32A DP MCB -2.Nos

4

-

-

... More
SITC of Medical Equipment Panel (Central Bldg),The panel shall be comprising of following & IEC 61439, Panel should be fully compartmentallised, wall mounted with M.S. Channel dully painted, fabricated of 14/16swg CRCA sheets completely derusted, chemically treated and powder coated with approved shade, ON - Off Indicating LED lamp, locking arrangements, withdual source intelligent flush mounted panel meter three phase four wire (IPM) 415V CT/ PT site programmable class I flush mounted (96 x 96mm) meter with voltage, current, frequency, power factor , ON hrs, kWh and LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden as per SLD having following items:- Main I/O 400 Amp FP MCCB. Bus bar chamber TPN & E with aluminium bars Outgoing- 250A TP MCCB- 1 No. 100A TP MCCB- 2 N0s., 63A FP MCB-4Nos, 32A FP MCB -4.Nos

1

-

-

... More
SITC of Meter Panel for Type I Qtr. Building (16 Quarters) having details as below & IEC 61439 for fixing meters complete with wiring, fittings and accessories, ON - Off Indicating LED lamp, locking arrangements and painting and 100 x100mm Display of Acrelyc sheet 2mm Thick for each meter,(size adequate for the following equipment, internal wiring and termination of external cables, lugs and glands and conduits as required, comprising of the following: - Incomer 100A 4 pole MCCB - 1 No Busbars 100A TPN & EARTH 25A DP MCB's -17 Nos. static energy meter with 240V 50 Hz. AC supply 5 to 30 A, ISI mark, accuracy class 1.0 with backlit LCD display, (measuring and display kWh, V, I, kW six month history of energy and MD in kVA ) - 17 Nos

1

-

-

... More
SITC of Meter Panel for Type II Qtr. Building (20 Quarters) having details as below & IEC 61439 for fixing meters complete with wiring, fittings and accessories, ON - Off Indicating LED lamp, locking arrangements and painting and 100 x100mm Display of Acrelyc sheet 2mm Thick for each meter,(size adequate for the following equipment, internal wiring and termination of external cables, lugs and glands and conduits as required, comprising of the following: - Incomer 400A 4 pole MCCB - 1 No Busbars 400A TPN & EARTH 25A DP MCB's -21 Nos. Static energy meter with 240V 50 Hz. AC supply 10 to 60 A, ISI mark, accuracy class 1.0 with backlit LCD display, (measuring and display kWh, kVAh, V,I,PF, frequency, kW, kVA, six months history of Energy & MD in kW & kVA ) - 21 Nos

2

-

-

... More
SITC of Meter Panel for Type III Building (12 Quarters) having details as below & IEC 61439 for fixing meters complete with wiring, fittings and accessories, ON - Off Indicating LED lamp, locking arrangements and painting and 100 x100mm Display of Acrelyc sheet 2mm Thick for each meter,(size adequate for the following equipment, internal wiring and termination of external cables, lugs and glands and conduits as required, comprising of the following: - Incomer 200A 4 pole MCCB - 1 No Busbars 200A TPN & EARTH 40A DP MCB's -13 Nos. Static energy meter with 240V 50 Hz. AC supply 10 to 60 A, ISI mark, accuracy class 1.0 with backlit LCD display, (measuring and display kWh, kVAh, V,I,PF, frequency, kW, kVA, six months history of Energy & MD in kW & kVA ) - 13 Nos

1

-

-

... More
SITC of Meter Panel for Type 4 (1 Quarter) Bldg having details as below & IEC 61439 for fixing meters complete with wiring, fittings and accessories, locking arrangements and painting and 100 x100mm Display of Acrelyc sheet 2mm Thick for each meter,(size adequate for the following equipment, internal wiring and termination of external cables, lugs and glands and conduits as required, comprising of the following: - 32A DP MCB's -1 Nos. static energy meter with 240V 50 Hz. AC supply 5 to 30 A, ISI mark, accuracy class 1.0 with backlit LCD display, (measuring and display kWh, V, I, kW six month history of energy and MD in kVA ) - 1 Nos

1

-

-

... More
Supplying, installing, testing and commissioning FR, XLPE armoured cable 4 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU (for DG Set control Cabeling)

35

-

-

... More
Supplying, erecting, testing and commissioning of diesel generating set with alternator of 125 kVA output continuous rating, 3 phase, 415 V, 50 Hz, 0.8 p.f., A.C. supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2/G3 and maximum fuel consumption 21.4 ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads, with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 230 ltr etc., on provided M20 grade CC foundation as per specification no. GEN-DG

2

-

-

... More
Supplying, erecting, testing and commissioning of Microprocessor based Generator Control Unit (Synchronization panel) panel suitable for diesel generating set of 320 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features and safeties etc as per specification no. GEN-SYNC.

1

-

-

... More
Supplying, installing, testing and commissioning of ETC solar water heating system without heat exchanger type of 500 LPD capacity with SS water tank of 0.5 mm thickness conforming to IS1239 Part-I :2004 complete as per specification no. ESD-SHWS-ETC

20

-

-

... More
Supplying and erecting 20/25 mm (ID/OD) Chlorinated polyvinyl chloride pipe (CPVC), thickness 2.6 mm on forming to IS 15778 (CTS Series) with necessary CPVC fittings and solvent cement for Solar Water Heater System as per specification No. ESD-HWP/CPVC

400

-

-

... More
Supplying and erecting 25/32 mm (ID/OD) Chlorinated polyvinyl chloride pipe (CPVC), thickness 3.2 mm conforming to IS 15778 (CTS Series) with necessary CPVC fittings and solvent cement for Solar Water Heater System as per specification No. ESD-HWP/CPVC

200

-

-

... More
Providing and fixing high-density polyethylene (HDPE) container one piece moulded triple layer water tank made out of high density polyethylene and built corrugated inclusive of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow pipe inclusive of all tanks capacity 20000 litres. (20 N0s of 1000 Ltrs)

20000

-

-

... More
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. ( Solar Tank frame)

1160

-

-

... More
SUB- WORK - NO-3 Providing Fire Fighting & Fire Alarm system Works to proposed Upgradation of 30 Bedded to 100 beded Sub District Hospital and Staff Residential Buildingss at Mangalwedha, Tal.- Mangalwedha Dist.- Solapur. Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete.

24

-

-

... More
Supplying and erecting ABC powder type fire extinguisher as per IS : 13849 /15683 of 6 kg capacity with necessary clamp for erection on wall.

50

-

-

... More
Supplying, installation, testing and commissioning of main fire pump (MFP / EP) suitable for water discharge of 2280 to 2850LPM at 80 to 60 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 45kW or of suitable kW capacity for manual/automatic operation and consisting of following: (a) Horizontal type, single stage, centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/ SSC /EP

1

-

-

... More
Supplying, installation, testing and commissioning of jockey fire pump (JP) suitable for water discharge of 180 LPM at 70 to 50 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 5.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal/vertical type, multi stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003)complete, as per specification no. FF-MFP/JP

1

-

-

... More
Supplying, installation, testing and commissioning of booster fire pump [BP] suitable for water discharge of 450 LPM at 35 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 5.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal/vertical type, single/multi stage, centrifugal casing pump of cast iron body & bronze/CI impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/BP

1

-

-

... More
Supplying, installation, testing and commissioning of booster fire pump [BP] suitable for water discharge of 900 LPM at 35 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 7.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal/vertical type, single/multi stage, centrifugal casing pump of cast iron body & bronze/CI impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation on with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d)Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/BP

4

-

-

... More
Supplying, installation, testing and commissioning of main fire pump (MFP/DP) suitable for water discharge of 2280 to 2850 LPM at 90 to 60 m head driven by 76 HP or suitable HP capacity diesel engine at required working speed suitable for manual/automatic operation and consisting of following : (a) Horizontal type, single stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520. (b) Water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12/24 volts DC electric starting equipment with battery of required AH capacity with necessary charger suitable to work on 230v, 50Hz AC supply, diesel tank of minimum 150ltr capacity with first filling of diesel up to 100% level with necessary piping with valves up to engine, exhaust pipe extended up to 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications etc. as required. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with engine assembly and accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/DP

1

-

-

... More
Supplying, erecting, testing & commissioning of fire pump control panel (FCP) of cubical construction, floor mounted type, fabricated from minimum 2 mm thick CRCA sheet, compartmentalised with hinged lockable doors, with enclosure protection class IP54, duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003), cable alley, inter connection with suitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessories, mountings and internal wiring with adequate size copper conductor cable, earth terminals, numbering etc. complete in all respect, suitable for satisfactory operation of main fire pump and jockey (pressurisation) pumps (1working+1standby) with necessary accessories, wiring &cabling along with allied accessories with following incoming and outgoings, suitable for automatic & manual operation on 415V, 3 phase, 50Hz ac supply as per specifications the capacity of electric motor driven pump are as follows a. Main fire pump(MFP) having capacity of 30 kW 1no (1 working) b. Jockey pump(JP) capacity of 5.5KW 2 nos(1 working +1 standby, alternate run per start in auto mode) D. 45HP main diesel engine driven fire pump 1. Main incomer FP SFU having rotary handle with HRC fuses of suitable rating. 2. Electrolytic grade copper strips for busbar of suitable sizes for main incomer and branches to motor SFU's, starters & outgoing terminals with necessary accessories like stainless steel nut bolts with spring washers for connections, mounted on required no of epoxy or porcelain support insulators of suitable ratings etc. 3. Individual pump TPN SFU having rotary handle with HRC fuses of suitable rating. Each 182320 4. Digital voltmeter & ammeter & RYB indicating lamps & push buttons & SPP, O/L & phase reversal protection with emergency stop switch. 5. TPN SPD 100kA Type 1 +2 tested. 6. Required pressure transducer with pressure indication on panel with cabling required for monitoring & automatic operation of fire pumps. 7. System controller to control operation of main electric fire pump, jockey (pressurization) pumps in sequence with interlocking for operation of pumps as per specification with automatic/manual operation with selector switch & alternate run of standby Pumps consisting of relays, timers. sensors, annunciation window for fault indication, complete as per specification. 8.Suitable capacity electric motor starters for all individual pumps with necessary push buttons & indications. 9. Siren of required capacity to be activated when main pump starts & allied accessories as per requirements of local CFO or as directed by engineer in charge. 10. Danger board as per IS. 11. Spare HRC fuses minimum 2nos of each individual rating with required bakelite fuse holder for main & jockey fire pumps MFP=(1working), JP = (1working+1standby, alternate run per start in auto mode) complete panel, as per specification no. FF-MFP/ECP D. For addition of 45HP main diesel engine driven fire pump (1 standby), add as follows in the basic cost of Item no 13-5-1 towards required 12/24 v battery charger and diesel engine starter along with necessary accessories, indicators etc. with necessary interlocking and updation of control logic with interlocking for operation of pumps MFP for main (1working+1standby mode) & jockey fire pumps (1working+1standby, alternate run per start in auto mode) , The control for diesel engine comprises of automatic /manual selector switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode indicating lamp for high/ low Lub. oil pressure, high water temp and engine on indication battery charger suitable for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC voltmeter, and 0-20 A DC ammeter with all standard relays and accessories required for automatic operation of diesel engine with interlocking for operation of main fire pumps.

1

-

-

... More
Supplying & erecting D.O.L Starter suitable for 415 V, 3 phase 50 cycles with no volt coil and overload element with necessary materials and connected to supply up to 7.5 H.P.

5

-

-

... More
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.

42

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 50 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

150

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

22

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

110

-

-

... More
Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware.

8

-

-

... More
Providing & erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 150 mm width & 20 mm height complete with necessary hardware.

8

-

-

... More
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no.EA-EP

4

-

-

... More
Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete

40

-

-

... More
Making cement concrete foundation in 1:2:4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) (for pumps).

2

-

-

... More
Carrying out core cutting of size 3" to 5" dia x 15" length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original.

1

-

-

... More
Supplying and erecting G.I. pipe ‘C’ class ERW 25 mm dia with necessary fittings complete as per specification no. FF-PP

2107

-

-

... More
Supplying and erecting ISI mark GI pipe 32 mm. dia ‘C” class at position with accessories complete. Specification no. CW-PLB/GP.

865

-

-

... More
Supplying and erecting ISI mark GI pipe 40 mm. dia ‘C” class at position with accessories complete. Specification no. CW-PLB/GP.

330

-

-

... More
Supplying and erecting G.I. pipe ‘C’ class ERW 50 mm dia with necessary fittings complete as per specification no. FF-PP

155.7

-

-

... More
Supplying and erecting G.I. pipe ‘C’ class ERW 65 mm dia with necessary fittings complete as per specification no. FF-PP

101

-

-

... More
Supplying and erecting G.I. pipe ‘C’ class ERW 80 mm dia with necessary fittings complete as per specification no. FF-PP

392

-

-

... More
Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm dia with necessary fittings complete as per specification no. FF-PP

250

-

-

... More
Supplying and erecting G.I. pipe ‘C’ class ERW 150 mm dia with necessary fittings complete as per specification no. FF-PP

520

-

-

... More
Supplying and erecting G.I. pipe ‘C’ class ERW 200 mm dia with necessary fittings complete as per specification no. FF-PP

4

-

-

... More
Providing coating of bitumen paint & 4mm thick wrapping for underground 150 mm ring main of fire fighting system.

80

-

-

... More
Supplying and erecting 200 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV

1

-

-

... More
Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV

9

-

-

... More
Supplying and erecting 150 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV

7

-

-

... More
Supplying and erecting 150 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS

3

-

-

... More
Supplying and erecting 25 mm dia gun metal gate valve complete with PN16 pressure rating, as per specification no. FF-VL/GV

59

-

-

... More
Supplying and erecting gun metal single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV

53

-

-

... More
Supplying and installing wall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) along with necessary accessories complete as per specification no. FF-FFA/HV

41

-

-

... More
Supplying and erecting 63mm dia, reinforced rubber lined (R.R.L.) hose pipe, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL

106

-

-

... More
Supplying and erecting gun metal branch pipe of 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specification no. FFFFA/NZ

53

-

-

... More
Supplying and erecting 150 mm dia fire brigade header suitable for supplying water in fire tank complete as per specification no. FF-FA/FBC

1

-

-

... More
Supplying and erecting fire brigade header ( Siamese connection )of 150 mm dia, for supplying water in fire tank complete as per specification no. FFFA/FMC

1

-

-

... More
Supplying and erecting 300 mm dia 1.5m in height air vessel / tank fabricated from min 5mm thick M.S. sheet complete as per specification no. FF-FFA/ACT

1

-

-

... More
Supplying and erecting 20/25mm dia gun metal air release cock, with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV

10

-

-

... More
Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, erected with provided G.I. pipe, elbow etc. complete as per specification no. FF-FFA/PG

7

-

-

... More
Supplying and erecting 12/15 mm dia pressure switch with provided isolation valve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS

2

-

-

... More
Supplying and erecting brass orifice plate having 6 mm. thickness, 140 mm outer dia with required diameter of inner hole at every single outlet hydrant valve as per specification no. FF-FFA/OP

41

-

-

... More
Supplying and erecting M.S./CRCA cabinet for housing single hydrant valve of size ( 400 x 400 x 400)mm or hose pipe box of size ( 600 x 600 x 200) mm made from min. 1.5 mm thick CRCA sheet with angle iron work of min. of size (25 x 25 x 4) mm having front doors with viewing glass of size (200x150) mm and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5)

53

-

-

... More
Supplying, erecting, testing and commissioning of quartzoid bulb sprinkler, 15 mm (½") dia. NBCM Body chrome finished, 68º C fixed temperature rating with deflector disc of conventional construction complete as per specification no. FFSPR.

692

-

-

... More
Supplying, erecting, testing and commissioning vane type water flow detector 100 mm dia. with 1) Visual switch activation 2) Rugged switch assembly 3) Heavy duty aluminium pipe saddles 4)Durable metal enclosure 5) Steel U bolts for secure mounting 6) Two SPDT ( Single pole double track ) synchronised switches 7) serviceable without draining pipes.

2

-

-

... More
SITC of Sprinkler Flexible drop pipes with 1500mm long(UL Listed) made of Corrugated SS Tubing to with stand 16 Bar pressure with welded reducer on one end to directly accommodate sprinkler & female check-nut on the other end to connect to the branch pipe with supports complete

692

-

-

... More
SITC of self Luminous Exit Sign in accordance with BS5499as per sample approved by incharge (FIRE EXIT 300mm X 150mm)

20

-

-

... More
Providing Round bottom FIRE Bucket of 9 Litres capacity as per IS : 2546 made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and red outside with FIRE Mark, on provided stand/ wall hook.

12

-

-

... More
Providing Floor mounting stand for keeping 4 Nos. of FIRE buckets 1500mm in length, 900mm in height framemade out of 30x30x4 mm angle iron with cross supports forlegs, welded with 4 hooks and duly painted with one coat ofred lead and two coats of silver paint complete.

3

-

-

... More
Supplying, erecting, testing and commissioning manual call point (Pill box) with break glass push button and flip abort switch or agent release switch in metal enclosure complete as per specification no. FF-FAAS/MCP

17

-

-

... More
Supplying, erecting, testing and commissioning hooters having high (100dB @ 1m) and low (94dB @ 1m) volume setting, group addressing facility allowing multiple sounders to be activated with CRCA enclosure complete as per specification no. FF-FAAS/HTR

17

-

-

... More
Supplying, installing, testing and commissioning 2 Zone, local signal control panel (LCP) with standard accessories complete as per specification no. FFFAAS/LCP

2

-

-

... More
Supplying, installing, testing and commissioning of intelligent addressable thermal/heat detector with rate of rise cum fixed temperature thermistor complete with base as required, suitable for temperature variations from -20°C to 38°C for fixed-heat and rate-of-rise type detectors and 0°C to 66°C for high heat type detectors, in built isolation mode, suitable for offices/ceiling cable trenches/less ventilation area's etc. with 3 years equipment replacement warranty IS : 2175 - 1988 reaffirmed 2000, IS 15908:2021 standards FF-AFAS/SD.

6

-

-

... More
Supplying, installing, testing and commissioning of addressable optical smoke detector, single/twin LED’s with 360 degree view, suitable for low voltage 15 to 32 V DC two wires supply, in-built locking mechanism to check the removal and pilferage of the detector, in built isolation mode, start up current 300μA and alarm condition current shall be maximum 6.5 mA, operating temperature 0°C to 50°C, humidity 0-95% RH, IP 41, conforming to IS 2189: 2008, 11360_1985_Reff2020 EN 54 or UL Approved with 3 years equipment replacement warranty FFAFAS/SD

460

-

-

... More
Supplying, installing, testing and commissioning of addressable manual call points ( break glass type/pull station type), made of addressable break glass plastic square in shape surface/flush mounted with "Break Glass" massage embedded on the glass, complete erected with mounting base and required accessories conforming to EN 54 or UL listed with 3 years equipment replacement warranty FF-AFAS/MCP.

26

-

-

... More
Supplying, installing, testing and commissioning of addressable horn cum strobe sound/ hooter, output frequency 500 to 1000 Hz with dB as per Chart given in IS 15908:2021, with flashing at 1 Hz over the strobe’s entire operating voltage range EN 54, conforming to IS 2189: 2008, IS 15908:2021 standards with 3 years equipment replacement warranty FF-AFAS/SSH.

26

-

-

... More
Supplying, installing, testing and commissioning of addressable fire control/relay module complete as required, with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 reed relays, EN 54 or UL Listed FF-AFAS/CRM

26

-

-

... More
Supplying, installing, testing and commissioning of addressable fire monitor module complete as required. EN 54 or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/MM

26

-

-

... More
Supplying, installing, testing and commissioning remote response indicators suitable to operate on 5 - 28 V dc supply having FR Polymer ABS Housing complete as per specification no. FF-FAAS/RRI

9

-

-

... More
Supplying, installing, testing and commissioning FRLS, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU

4676.1

-

-

... More
Supplying, installing, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the 2 loop capacity and capable of supporting upto 250 devices and detectors per loop, with on-board LCD display with min 16 lines of text, operating at 230 V 50 HZ - AC with inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 min in alarm condition, suitable provision for network connectivity, interfacing with third party equipment via a MODBUS/ OPC/ L-ON interface etc. conforming to IS 15908:2021, IS 2189: 2008, EN 54 & VDS / FM/ UL 864 (10th edition) with 3 years replacement warranty FF-AFAS/CP.

1

-

-

... More
Supplying, installing, testing and commissioning of repeater panel with suitable battery backup of a minimum of 24 hours in normal condition and 30 min in alarm condition, 80 backlit alphanumeric LCD display with inbuilt buzzer to indicate fault/fire alarm, manual control keys for silence/mute and to reset the FACP from the repeater station. Panel size shall not more than 175 x 275 x 65 mm conforming to EN 54 or UL approved with 3 years equipment replacement warranty FF-AFAS/RP

1

-

-

... More
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. With PVC accessories on wall /ceiling as per specification No: WG-MA/CON.

440

-

-

... More
Supplying, erecting, testing and commissioning 120 W amplifier suitable to operate on 230 Volts A.C. / 12 Volts D.C. supply complete as per specification no. FF-PA/AFR

2

-

-

... More
Supplying, erecting, testing and commissioning 15 Watts sound column or ceiling mounted complete as per specification no. FF-PA/SOC

11

-

-

... More
Supplying, erecting, testing and commissioning stand mounted/handheld type wired microphone having 2 mV/Pa sensitivity, impedance level limit 300 ohms and 50 - 16000 Hz suitable to operate in -10 deg C to +55 deg C with min. 7 metre shielded cable and 3 Pin Professional XLR Connector, stereo jack complete as per specification no. FF-PA/MIC

2

-

-

... More
Supplying, erecting, testing and commissioning rust free microphone table stand of chrome plating / powder coating or S.S. material, up to 500 mm height and suitable base for sturdy mechanism ensuring trouble free movement complete.

2

-

-

... More
Supplying, erecting, testing and commissioning of 2 core shielded cable complete as per specification no. FF-PA/MCC

20

-

-

... More
Supplying, erecting, testing and commissioning of 1.5 sq. mm speaker wire complete.

550

-

-

... More
SUB- WORK - NO-4 Providing Street Lighting, Water Pumping Systemto proposed Upgradation of 30 Bedded to 100 beded Sub District Hospital and Staff Residential Buildingss at Mangalwedha, Tal.- Mangalwedha Dist.- Solapur. Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. X 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV

450

-

-

... More
Supplying and erecting integrated LED street light fitting 60W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 6600 Lumens, min. efficacy of 110 lumen/W, CRI70, CCT upto 6500K, THD10%, p.f. 0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2.

75

-

-

... More
Supplying and erecting integrated LED Bollard Cylindrical/Cubical shaped 800mm 8W IP65 & IK10 class having extrusion aluminium housing with polycarbonate diffuser, having system lumens output of Min. 800 Lumens, min. efficacy of 100 lumen/W, CRI80, CCT upto 6500K, THD10%, p.f. 0.90, operating range of 140-240V, inbuilt surge protection of 2 kV, Life class of 25,000 Hrs. at L50B50, including driver complete with 2 Year warranty as per specification No FG-ODF/FLS2.

29

-

-

... More
Supplying and erecting integrated LED flood light fitting Max. 100W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 12000 Lumens, min. efficacy of 120 lumen/W, CRI70, CCT upto 6500K, THD10%, p.f. 0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2

18

-

-

... More
Supplying and erecting integrated LED Post Top 45W IP65 & IK10 class having die cast aluminium housing with UV protected polycarbonate diffuser, having system lumens output of Min.4500 Lumens, min. efficacy of 100 lumen/W, CRI80, CCT upto 6500K, THD10%, p.f. 0.90, operating range of 140-240V, inbuilt surge protection of 2 kV, Life class of 30,000 Hrs. at L50B50 , including driver complete with 2 Year warranty as per specification No FGODF/ FLS2.

15

-

-

... More
Supplying & erecting FRP box of size 250mm x 200mm x 100 mm, 2.7 mm thick complete on pole/wall as per specification No. CB-SB

15

-

-

... More
Supplying & erecting three phase, 415V, street light control panel up to the max load of 6kW, TPN MCB 40A, powder coated CRCA 14 SWG sheet, outdoor type, having IP54,IK10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protection on provided iron frame / CC foundation.

2

-

-

... More
Supplying, erecting & marking SPMCB 0.5A to 5A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

66

-

-

... More
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. ( Street Light Panel Foundation frame)

40

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

885

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

1275

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

675

-

-

... More
Supplying & erecting G.I. pipe ‘A’ class 50 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE

28

-

-

... More
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.

1728

-

-

... More
Supplying and erecting 12.5 m (clear height) motorized high-mast (Top -150mm, Bottom- 360mm) hot dipped galvanized material with average minimum thickness 65 micron, made from high tensile structure grade steel as per BSEN - 10025 S 355/E350 & 3mm thickness, with base plate 25 mm thick x OD 520 mm grade as per IS-2062, pole made in single section & submerge arc welded, with lowering & raising motorized unit, wire rope stainless steel 316 grade 2 nos., 7x19 construction 5mm, SG-DG U clamps, double drum with assembly 250 kg, 5x2.5 Sq.mm. flexible copper cable with lantern carriage assembly suitable for max. 12 nos. luminaires and its control gear box, lightning arrestor, arrangement for fixing aviation light, high-mast with serial number, factory inspection report/test report of high-mast should be provided as per specifications on provided foundation J type stud/bolts with necessary accessories complete as per specification no. OHPL/ HM (excluding luminaries)

3

-

-

... More
Providing & erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL

51

-

-

... More
Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT

27

-

-

... More
Providing and erecting galvanised 1000mm double arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT

24

-

-

... More
Supplying and erecting outdoor stand mounted feeder pillar for high-mast of the same manufacturer with 63A TPN MCB incomer, 24hr astronomical time switch with minimum 5 Years battery backup, , IP 54 and IK10 protection, 45 A TP contactor for automatic switching of luminaires, 2 no 9A contactors and raise/lower push button, and provision for termination of adequate size of incoming and outgoing cables complete erected in min. 14 SWG CRCA sheet box powder coated with supporting angles, self lock, gasket and slanting top erected on CC foundation complete.

3

-

-

... More
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no.EA-EP

2

-

-

... More
Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no.EA-EP

51

-

-

... More
Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete

25

-

-

... More
Making cement concrete foundation in 1:2:4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) for 3 nos St. Light Panel) ( 0.4x0.4x0.5m - 4 stand x 2 panels)

0.64

-

-

... More
Excavating soft murum / soft soil road by chiselling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site good complete.

0.51

-

-

... More
Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole).

51

-

-

... More
Making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose).(For Bollard Foundation), (0.3x0.3x0.5m)x10nos

1.31

-

-

... More
Making M- 20 cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq. m at 2 m depth including excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 16 m raising lowering high mast).

3

-

-

... More
Supplying, erecting & marking FPMCB 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

1

-

-

... More
Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame

11

-

-

... More
Supplying, fixing and commissioning MCB type change over switch 4 pole, 63A with 3 positions (I-O-II) with centre off position as per specification no. SW-SWR/ MCBCOS

10

-

-

... More
Supplying and erecting bus bar chamber triple pole with neutral with four aluminium bars, 500V, 100A having 15mm (Width) X 3 mm (Thickness), with 99.9 % aluminium purity as per E91E Grade & Current Density 0.8 A per sq. mm. compliance to IS 5082 and Enclosure fabricated with 16 SWG CRCA sheet and epoxy paint, with suitable number of ways and with SMC/DMC Insulators and accessories of suitable rating complete as per specification no. CPBB

0.5

-

-

... More
Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete

10

-

-

... More
Supplying and erecting minimum Three & above star rated submersible pump set suitable for erection on open well of 3.75 KW/5 HP with 415 V 50 c/s. A.C. supply, having delivery head from 43 to 11m and discharge from 120 to 840 litres. per minute & pipe of Suction 65mm / Delivery 50 mm diameter erected with necessary H type clamps as per specification No. WP-OSP ( Hospital - 1, Type I-1, Type II-2, Type III-1)

10

-

-

... More
Supplying and erecting minimum Three & above star rated 1 phase, 230 V, 50 Hz, submersible pump set of 1.5 KW/2HP suitable for erection on open well, pump having delivery head from 29 to 7 m and discharge from 30 to 600 litres. . per minute & pipe of Suction 50 mm/Delivery 50 mm diameter erected with necessary H type clamps as per specification No. WP-OSP (Kitchen - 1, Laundry-1, Mortury-1, Type IV-1)

8

-

-

... More
Supplying & erecting Dewatering Monoblock pump set 415V, 3 phase, 50C/s, A.C. supply of 2.25KW/ 3 H.P., of 12 to 26 m head with 560 to 70 LPM discharge, 10.5mm Solid Handling Capacity, non clogging minimised abrasive wear, large impeller clearance & maintenance free pump set with water proof cable duly sealed with epoxy material built in protection to prevent the motor from burn out due to abnormal operation. specially designed high efficiency motor with F class insulation & the pump mechanically sealed in the oil chamber,. etc. complete as per specification no. DWP- SMP

2

-

-

... More
Supplying & erecting automatic control panel for 1 Ph, 230 volt, A.C. Submersible/centrifugal pump set up to 3 HP consisting of DOL starter Of suitable relay range S.P.P., Combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection.

2

-

-

... More
Supplying & erecting automatic control panel for 3 Phase , 415 volt, A.C, Submersible/ centrifugal pump set up to 7.5 HP consisting of DOL starter having relay range 9-14 AMP,S.P.P., Combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc .

18

-

-

... More
Supplying & erecting flat flexible 3 core 4 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete.

360

-

-

... More
Supplying & erecting Water level controller 230/415 V, A.C. , Four way under ground & Over head tank operation only.

6

-

-

... More
Supplying and erecting 50 mm dia gun metal gate valve complete with PN16 pressure rating, as per specification no. FF-VL/GV

18

-

-

... More
Supplying and erecting ISI mark GI pipe 50 mm dia.‘B’ class at position with accessories complete as per specification no. CW-PLB/GP.

90

-

-

... More
Supplying and erecting non return valve 50 mm dia in position made of gun metal complete.

18

-

-

... More
SUB- WORK - NO- 5 Providing passengers & Strecher Lift (MR) Works to proposed Upgradation of 30 Bedded to 100 beded Sub District Hospital and Staff Residential Buildingss at Mangalwedha, Tal.- Mangalwedha Dist.- Solapur. Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete.

44

-

-

... More
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.

44

-

-

... More
Supplying and erecting modular type 3 pin 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.

44

-

-

... More
Supplying and erecting PVC Surface modular switch box with double mounting plate for 4 module duly erected.

44

-

-

... More
Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI80, CCT upto 6500K, Beam Angle of 120 deg., THD10%, p.f. 0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty.

44

-

-

... More
Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame.

16

-

-

... More
Supplying, fixing and commissioning 2 pole, RCBO 6/10/16/20/25A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO

8

-

-

... More
Supplying, fixing and commissioning 4 pole RCBO 32/40A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO

8

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU

240

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 2.5 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU

176

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 4 sq mm copper conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU

176

-

-

... More
Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results as per specification no. EA-EP

16

-

-

... More
Supplying and erecting annealed bare copper wire of high purity of required sizes used for earthing on wall with necessary copper clamps fixed on wall/cable/conduit with screws complete.

24

-

-

... More
SITC of Electric Traction Passenger Lift with · Rated capacity :- 4 Passenger/272Kg · Floors :- G+4 floor (5 Stops/5 Landings) · Travel :-12.8 mtrs · Location of Lift Machine:- MR · Rated speed :- 1.0mps VS · Car/Landing door clear opening of 800 mm wide x 2000 mm high · Clear Car size of 1100mm wide x 700mm deep x 2250mm high · Lift shaft available having clear size of 1800mm wide x1500mm deep, 1500mm Pit depth,4250mm Overhead. · Doors type :- COPO/TOPO Doors with frame made from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory). · Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge. · COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor. · LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings. · Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. · ARD complete with necessary SMF VRLA batteries. · Fireman controller having fireman switch at fire Landing. · CCTV surveillance system comprises of 2 nos minimum 2.0 MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup min. 90 days with min. 18” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge. · Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength. · Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work. · Minor civil work such as alteration work if any necessary for erection of landing door frames and it's accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT. · General: - Job includes entire procedure of obtaining all necessary erection permissions & "License to Work the Lift" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. · The above rate includes Fully Comprehensive AMC for one year from the date of commissioning. Add On: A. For Lift travelling up to six floors or at a speed of 1.0 mps, add as below, 2. For Lift having 800mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade solid(non-cladded) landing door [Two panel], this includes all necessary accessories like LOP's with UP/DN buttons-arrows-indicators, extension of guide rails, shaft wiring with trunking, travelling cables, main hoisting ropes/belts, & OSG rope landing doors with all accessories etc. necessary for the normal safe functioning of lift installation complete. - for 3 floors Add On: B. For Lift travelling up to six floors or at a speed of 1.0 mps, add as below, 1. For Lift travelling above First floor & up to Sixth floor

1

-

-

... More
SITC of Electric Traction Passenger Lift with · Rated capacity :- 6 Passenger/408Kg · Floors :- G+5 floor (6 Stops/6 Landings) · Travel :-16 mtrs · Location of Lift Machine:- MR · Rated speed :- 1.0mps VS · Car/Landing door clear opening of 800 mm wide x 2000 mm high · Clear Car size of 1100mm wide x 1000mm deep x 2250mm high · Lift shaft available having clear size of 1800mm wide x1800mm deep, 1500mm Pit depth,4250mm Overhead. · Doors type :- COPO/TOPO Doors with frame made from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory). · Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge. · COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor. · LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings. · Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. · ARD complete with necessary SMF VRLA batteries. · Fireman controller having fireman switch at fire Landing. · CCTV surveillance system comprises of 2 nos minimum 2.0 MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup min. 90 days with min. 18” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge. · Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength. · Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work. · Minor civil work such as alteration work if any necessary for erection of landing door frames and it's accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT. · General: - Job includes entire procedure of obtaining all necessary erection permissions & "License to Work the Lift" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. · The above rate includes Fully Comprehensive AMC for one year from the date of commissioning. Add On: A. For Lift travelling up to six floors or at a speed of 1.0 mps, add as below, 2. For Lift having 800mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade solid(non-cladded) landing door [Two panel], this includes all necessary accessories like LOP's with UP/DN buttons-arrows-indicators, extension of guide rails, shaft wiring with trunking, travelling cables, main hoisting ropes/belts, & OSG rope landing doors with all accessories etc. necessary for the normal safe functioning of lift installation complete. - for 4 floors Add On: B. For Lift travelling up to six floors or at a speed of 1.0 mps, add as below, 1. For Lift travelling above First floor & up to Sixth floor

2

-

-

... More
SITC of Electric Traction Passenger Lift with · Rated capacity :- 6 Passenger/408Kg · Floors :- G+3 floor (6 Stops/6 Landings) · Travel :-9.6 mtrs · Location of Lift Machine:- MR · Rated speed :- 1.0mps VS · Car/Landing door clear opening of 800 mm wide x 2000 mm high · Clear Car size of 1100mm wide x 1000mm deep x 2250mm high · Lift shaft available having clear size of 1800mm wide x1800mm deep, 1500mm Pit depth,4250mm Overhead. · Doors type :- COPO/TOPO Doors with frame made from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory). · Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge. · COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor. · LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings. · Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. · ARD complete with necessary SMF VRLA batteries. · Fireman controller having fireman switch at fire Landing. · CCTV surveillance system comprises of 2 nos minimum 2.0 MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup min. 90 days with min. 18” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge. · Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength. · Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work. · Minor civil work such as alteration work if any necessary for erection of landing door frames and it's accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT. · General: - Job includes entire procedure of obtaining all necessary erection permissions & "License to Work the Lift" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. · The above rate includes Fully Comprehensive AMC for one year from the date of commissioning. Add On: A. For Lift travelling up to six floors or at a speed of 1.0 mps, add as below, 2. For Lift having 800mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade solid(non-cladded) landing door [Two panel], this includes all necessary accessories like LOP's with UP/DN buttons-arrows-indicators, extension of guide rails, shaft wiring with trunking, travelling cables, main hoisting ropes/belts, & OSG rope landing doors with all accessories etc. necessary for the normal safe functioning of lift installation complete. - for 2 floors Add On: B. For Lift travelling up to six floors or at a speed of 1.0 mps, add as below, 1. For Lift travelling above First floor & up to Sixth floor

1

-

-

... More
SITC of Electric Traction Passenger cum Stretcher/Hospital Lift with · Rated capacity :- 20 Passenger/1360Kg · Floors :-G+4 floor (5 Stops/5 Landings) · Travel :-18 mtrs · Location of Lift Machine:- MR · Rated speed :- 1.0mps VS · Car/Landing door clear opening of 1200mm wide x 2000 mm high · Clear Car size of 1300mm wide x 2400mm deep x 2250mm high · Lift shaft available having clear size of 2200mm wide x 3300mm deep, 1600mm Pit depth, 4250 mm Overhead. · Doors type :- COPO/TOPO Doors with frame made from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory). · Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge. · COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor. · LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings. · Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. · ARD complete with necessary SMF VRLA batteries. · Fireman controller having fireman switch at fire Landing. · CCTV surveillance system comprises of 2 nos minimum 2.0 MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup min. 90 days with min. 18” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge. · Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength. · Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work. · Minor civil work such as alteration work if any necessary for erection of landing door frames and it's accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT. · General: - Job includes entire procedure of obtaining all necessary erection permissions & "License to Work the Lift" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. · The above rate includes Fully Comprehensive AMC for one year from the date of commissioning. Add On: A. For Lift travelling up to six floors or at a speed of 1.0 mps, add as below, 6. For Lift having 1200mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade solid(non-cladded) landing door [Two panel], this includes all necessary accessories like LOP's with UP/DN buttons-arrows-indicators, extension of guide rails, shaft wiring with trunking, travelling cables, main hoisting ropes/belts, & OSG rope landing doors with all accessories etc. necessary for the normal safe functioning of lift installation complete. - for 3 floors Add On: B. For Lift travelling up to six floors or at a speed of 1.0 mps, add as below, 1. For Lift travelling above First floor & up to Sixth floor

1

-

-

... More
SITC of Electric Traction Passenger cum Stretcher/Hospital Lift with · Rated capacity :- 20 Passenger/1360Kg · Floors :-G+4 floor (5 Stops/5 Landings) · Travel :-12.8 mtrs · Location of Lift Machine:- MR · Rated speed :- 1.0mps VS · Car/Landing door clear opening of 1100mm wide x 2000 mm high · Clear Car size of 2000mm wide x 1500mm deep x 2250mm high · Lift shaft available having clear size of 2800mm wide x 2200mm deep, 1600mm Pit depth, 4250 mm Overhead. · Doors type :- COPO/TOPO Doors with frame made from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory). · Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge. · COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor. · LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings. · Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. · ARD complete with necessary SMF VRLA batteries. · Fireman controller having fireman switch at fire Landing. · CCTV surveillance system comprises of 2 nos minimum 2.0 MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup min. 90 days with min. 18” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge. · Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength. · Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work. · Minor civil work such as alteration work if any necessary for erection of landing door frames and it's accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT. · General: - Job includes entire procedure of obtaining all necessary erection permissions & "License to Work the Lift" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. · The above rate includes Fully Comprehensive AMC for one year from the date of commissioning. Add On: A. For Lift travelling up to six floors or at a speed of 1.0 mps, add as below, 6. For Lift having 1200mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade solid(non-cladded) landing door [Two panel], this includes all necessary accessories like LOP's with UP/DN buttons-arrows-indicators, extension of guide rails, shaft wiring with trunking, travelling cables, main hoisting ropes/belts, & OSG rope landing doors with all accessories etc. necessary for the normal safe functioning of lift installation complete. - for 3 floors Add On: B. For Lift travelling up to six floors or at a speed of 1.0 mps, add as below, 1. For Lift travelling above First floor & up to Sixth floor

3

-

-

... More
SUB- WORK - NO-6 Providing HVAC System Works to proposed Upgradation of 30 Bedded to 100 beded Sub District Hospital and Staff Residential Buildingss at Mangalwedha, Tal.- Mangalwedha Dist.- Solapur. Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.3TR to 1.6TR capacity having ISEER minimum 5.00 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. APAC/ WAC (all Network Room)

1

-

-

... More
Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor. room air conditioning unit 1.7TR to 2.0TR capacity having ISEER minimum 5.0 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position in provided recess with wooden frame complete specification no. AP-AC/WAC (Mortury Body Holding)

6

-

-

... More
Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 12mm complete.

56

-

-

... More
Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 16mm complete.

56

-

-

... More
Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 12 mm for solar water heater/AC system.

56

-

-

... More
Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 16 mm for solar water heater/AC system.

56

-

-

... More
Supply , Installation , Testing & Commissioning of Double skinned Air Handling Unit with with Inlet EU - 4 Filter, DX Coil, UV Lamps, DIDW Fan VFD Compatible, Motors, Drive Set, EU4 +EU 5 Combi Filter, Supply Air Damper, Return Air Damper, Fresh Air Damper, Min. Filter efficiency will be as per Ashrae Standard 52.2-2017 table 12.7. prefilter section with non woven synthetic washable media before cooling coil, fine filter section with Synthetic fibre media with frame material made out by G.I. with flange rigid media. Frame shall be properly sealed with gasket. Coil UVGI should be provided alongwith Special HVAC Application model VFD as per following specifications. DX Coil- 28 TR, 7000 CFM Vs 80 mm Static In 21.2 deg.C DB / 14.8 deg.C WB Out 7.7 deg.C DB / 7.2 deg.C WB Electric Reheaters 3 KW X10 Nos (OBS ICU & HDU Ward)

1

-

-

... More
Supply , Installation , Testing & Commissioning of Double skinned Air Handling Unit with with Inlet EU - 4 Filter, DX Coil, UV Lamps, DIDW Fan VFD Compatible, Motors, Drive Set, EU4 +EU 5 Combi Filter, Supply Air Damper, Return Air Damper, Fresh Air Damper, Min. Filter efficiency will be as per Ashrae Standard 52.2-2017 table 12.7. prefilter section with non woven synthetic washable media before cooling coil, fine filter section with Synthetic fibre media with frame material made out by G.I. with flange rigid media. Frame shall be properly sealed with gasket. Coil UVGI should be provided alongwith Special HVAC Application model VFD as per following specifications. DX Coil- 36 TR, 8500 CFM Vs 80 mm Static In 21.2 deg.C DB / 14.8 deg.C WB Out 7.7 deg.C DB / 7.2 deg.C WB Electric Reheaters 3 KW X10 Nos (ICU Ward)

1

-

-

... More
Supplying, erecting, testing and commissioning of 18HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56°C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete. (OBC ICU & HDU Ward - 2 x 18 HP = 36HP)

2

-

-

... More
Supplying, erecting, testing and commissioning of 22HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56°C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete. ( ICU Ward - 2x22 HP= 44HP)

2

-

-

... More
Supply and installation of Valve station for AHU to regulate the refrigiration inside the system with neassary controller wich are present in side the outdoor unit to regulate the refrigirant in side the system for temprature AHU EEV Kit (40HP / 56.1~112 kW)

2

-

-

... More
Supply, installation, testing and commissioning wireless remote control having colour LCD panel, real time clock, temperature limitation (16 to 30° C, functions like filter clean reminder timer suitable to communicate with wired controller complete.

2

-

-

... More
Supplying, erecting, testing and commissioning centralised programmable remote control panel (HMI) touch manager controls minimum 16 system of 64 ODU's can be Controlled and up to 992 IDU's can be individually mounted and controlled indoor units having colour min 200mm size LCD touch panel, yearly schedule, power proportional distribution function, temperature limitation, history function complete erected on wall integrated with provided fire alarm system.

2

-

-

... More
Supplying and erecting GI sheet 0.6 mm (24 SWG) having zinc coating of 275 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint (FOR FRESH AIR CONNECTIONS & CRITICAL PIECES IF REQUIRED) Thickness 0.63 mm sheet

320

-

-

... More
Supplying and erecting GI sheet 0.8 mm (22 SWG) having zinc coating of 275 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint.

1280

-

-

... More
Supplying and erecting GI sheet 1 mm (20 SWG) having zinc coating of 275 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint.

100

-

-

... More
Supplying and erecting GI sheet 1.25 mm (18 SWG) having zinc coating of 350 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint.

25

-

-

... More
Providing adhesive thermal insulation for supply return air duct with 19mm nitrile rubber insulation having R-value as per the prevailing provisions in ECBC- 2017. ( Internal & External - Return )

1600

-

-

... More
Providing and applying of acoustic insulation for air ducts with 25mm thick, 48 kg/cu.m fiber glass faced with RP tissue and covered with 26 SWG perforated aluminium sheets complete.

50

-

-

... More
Supply, installation, testing and commissioning of manually operated, opposed blade, duct mounted, flanged volume control dampers of required sizes in GI construction with operating mechanism, mounting arrangement, rubber refrigerant kits etc. complete.

2

-

-

... More
Supply, installation, testing and commissioning of volume control box with collar for control damper of required sizes in GI construction with operating mechanism, mounting arrangement, rubber refrigerant kits etc. complete.

2

-

-

... More
Supply, fabrication, installation and testing of flexible canvas connections constructed between ductable unit/dampers/ducting of suitable size with fire resist flexible double canvas sleeve complete.

2

-

-

... More
Supplying & erecting tile type modular diffuser made from aluminium sheet with powder coated matching to the ceiling shade for provided supply and return air complete.

8

-

-

... More
Supplying and erecting aluminium powder coated linear grill of suitable size for width length without collar dampers having matching colour with the existing false ceiling and suitable for deflection of 15/30/45°.

2

-

-

... More
Supplying & erecting 20 SWG G.I sheet metal cawl rectangular /round shaped with 25 x 25x 3 (mm) angle iron frame, metal mesh to avoid birds entry with necessary material, suitable for exhaust fan of 450 mm as per specification no FGFAS/MSC (Fresh air louvers)

2

-

-

... More
Supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 41.3mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete.

25

-

-

... More
Supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 34.9mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete.

45

-

-

... More
supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 28.6mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete.

50

-

-

... More
supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 22.2mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiation with OEM standards of VRV/VRF air conditioning system complete.

35

-

-

... More
supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 15.9mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiation with OEM standards of VRV/VRF air conditioning system complete.

45

-

-

... More
supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 12.7mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiation with OEM standards of VRV/VRF air conditioning system complete.

20

-

-

... More
supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 9.5 mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete.

45

-

-

... More
supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 6.4mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete.

20

-

-

... More
Supplying and installation of high pressure grade required size copper connection Y or T- Joints/ refnet complete erected on wall/ceiling with supports/raceways, Nitrile rubber insulation, painting etc. with brazing and testing for leakages confirming the normal operation of the VRV/VRF air conditioning system.

5

-

-

... More
Poviding & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware.

50

-

-

... More
Providing & erecting hot dipped galvanised ladder type cable tray (Perforated) manufactured from 16 SWG (1.6 mm thick) GI sheet of 300 mm width & 75 mm height complete with necessary coupler plates & hardware.

100

-

-

... More
Providing & erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 150 mm width & 20 mm height complete with necessary hardware.

50

-

-

... More
Providing & erecting hot dipped galvanised cover suitable for perforated typeCable tray manufactured from 18 SWG `GI sheet of 300 mm width & 20 mm height complete with necessary hardware.

100

-

-

... More
Supplying and erecting 25/32 mm (ID/OD) Chlorinated polyvinyl chloride pipe (CPVC), thickness 3.8 mm conforming to IS 15778 (CTS Series) with necessary CPVC fittings and solvent cement for Solar Water Heater System as per specification No. ESD-HWP/CPVC

30

-

-

... More
Supplying and erecting 32/40 mm (ID/OD) Chlorinated polyvinyl chloride pipe (CPVC), thickness 3.8 mm conforming to IS 15778 (CTS Series) with necessary CPVC fittings and solvent cement for Solar Water Heater System as per specification No. ESD-HWP/CPVC

40

-

-

... More
Supplying and erecting 40/50 mm (ID/OD) Chlorinated polyvinyl chloride pipe (CPVC), thickness 3.8 mm conforming to IS 15778 (CTS Series) with necessary CPVC fittings and solvent cement for Solar Water Heater System as per specification No. ESD-HWP/CPVC

40

-

-

... More
Supplying and erecting mains with 3x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW

10

-

-

... More
Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. X 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV

25

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU

105

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU

80

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU

100

-

-

... More
Supplying, erecting, testing and commissioning of 2 core shielded cable complete as per specification no. FF-PA/MCC

25

-

-

... More
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.

750

-

-

... More
Supplying, Fixing, testing and commissioning motorised combined smoke & fire damper UL 555-S listed for Dynamic Rating in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications. Smoke & Fire Dampers with sensors, Extended Sleeve for Installation

2

-

-

... More
SUB- WORK - NO-7 Providing CCTV System to proposed Upgradation of 30 Bedded to 100 beded Sub District Hospital and Staff Residential Buildingss at Mangalwedha, Tal.- Mangalwedha Dist.- Solapur. Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.

264

-

-

... More
Supplying and laying HMS PVC conduit FRLS grade 25 mm dia. With necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.

792

-

-

... More
Supplying and erecting 3m HDMI cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete

1

-

-

... More
Supplying and installing cat-6 LSZH cable suitable for networking as per specification no. WG-COC/NC

1320

-

-

... More
Supplying and installing cat-6 armoured cable with ECCS tape suitable for networking as per specification No. WG-COC/NC

70

-

-

... More
Supplying and fixing 1 m UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC

44

-

-

... More
Supplying, fixing, and configuring 24 ports, POE switch in provided rack as per specification No. WG-NWC/ENS

5

-

-

... More
Supplying, installing and testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC.

88

-

-

... More
Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP

5

-

-

... More
Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x600x367 mm) as per specification No. WG-NAS/RAK

5

-

-

... More
Supplying, erecting, testing and commissioning of single phase input & 1 phase output 1 kVA capacity online pure sine wave UPS, with backup time of one hrs. PWM & IGBT based, with 0.8 to unity output pf complete with all protections as per specification no. AP-UPS (for CCTV)

1

-

-

... More
Supplying and erecting 12V/42Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete

3

-

-

... More
Supplying & erecting 8 TB internal Surveillance HDD suitable for SATA Port of NVR, interface transfer rate 6 GB/S, Maximum sustained transfer rate 210 MB/Sec to 213 MB/S. Drive bay supported 08+, Cameras supported up to 64, Cache (MB) 256, Load/Unload Cycle -3000000, Work Load Rating per Year 180TB, MTBF 1000000 Hrs. HTTPS. RoHS, UL, CE certified, duly erected in position in provided NVR as per specifications CCTV-HDD ( For Hospital Bldg)

8

-

-

... More
Supplying & erecting 55" professional LED display with 1920 *1080 ( Full HD) Display, suitable for 32/64 channel NVR and following features Brightness: minimum 500 Cd/m2 Contrast Ratio: minimum 1000:1 Viewing angle: 178/178 deg. Response time: maximum 8 ms Inputs: HDMI, VGA, BNC,USB, Audio In, Built-in speakers maximum 10 W, Suitable to operate on 100-240 V 50 Hz AC supply and 24/7 Duty Cycle duly erected on wall or table top with standard accessories like wall mount stand and wiring connections etc. complete as per specifications no. CCTV-MON

1

-

-

... More
Supplying & erecting of High definition 4/5 Megapixel IP IR Bullet Camera with following features Image Sensor : minimum 1/2.8" Progressive Scan CMOS, Video Resolution : minimum 2592 x 1520 Video Compression : H.264, H.265 or higher, at least Three individually configurable stream, Frame rate : minimum 25 fps at all resolutions, WDR : minimum 120 dB Wide Dynamic Range, ONVIF profile conformant, minimum IR distance : 50m, Lens Type : 2.8/4/6 mm Lens, fixed focal, Field of View : 2.8 mm, horizontal FOV 107°, vertical FOV 57°, diagonal FOV 129° 4 mm, horizontal FOV 86°, vertical FOV 47°, diagonal FOV 102° 6 mm, horizontal FOV 55°, vertical FOV 29°, diagonal FOV 65° Lux sensitivity - minimum 0.2 Lux at color, minimum 0.05 Lux at Black & White, 0.0 Lux (IR) Night Vision Distance minimum IR - 50m. Camera minimum Adjustment Angles - Pan : 350°, Tilt : 72°, Rotate : 350°. Power Supply : Support 12VDC & PoE, IP67, IK10 - Vandal Resistant. Built in micro SD/SDHC/SDXC card slot of minimum 128 GB, Built in microphone. minimum Input/Output - Audio in × 1, Audio Out × 1, Alarm in × 1, Alarm Out × 1. Image Settings : Rotate mode, saturation, brightness, contrast, sharpness, gain, white balance. Image Enhancements : Day/Night-Auto (ICR)/Color/Black & White, 3D Digital Noise Reduction, Automatic White Balance, Automatic Gain Control, Backlight Compensation, Highlight Compensation. Events : Privacy Masking, Motion detection, Scene change detection, Face capture, Video tampering, audio exception detection, Region entrance detection, Region exiting detection. Operating temperature ( -30 to 60° C ) . Security - User account and password protection, HTTPS, IP filter, IEEE 802.1X, digest authentication, user access log, TLS1.2, AES - 256, SSH/Telnet closed, FTP disabled. Protocol - DHCP, UDP, HTTP, HTTPS, NTP, DNS, RTP, RTSP, SMTP, SSL/TLS, TCP/IP, Secure Real-Time Transport Protocol (SRTP), Bonjour, SNMP and Secure shell (SSH) supported protocol. RoHS, WEEE, ISO-14001 and REACH compliant, UL/EN OR equivalent BIS/TECH/STQC or any indian standards as applicable, CE, FCC certified. duly erected in position on wall/ceiling/false ceiling/provided pole (mounting height not more than 5 meter) etc with all accessories etc complete as per specification no. CCTV-CAM

6

-

-

... More
Supplying & erecting of High definition 4/5 Megapixel IP IR Dome Camera with following features Image Sensor : minimum 1/2.8" Progressive Scan CMOS, Video Resolution : minimum 2592 x 1520 Video Compression : H.264, H.265 or higher, at least Three individually configurable stream, Frame rate : minimum 25 fps at all resolutions, WDR : minimum 120 dB Wide Dynamic Range, ONVIF profile conformant, minimum IR distance : 50m, Lens Type : 2.8/4/6 mm Lens, fixed focal, Field of View : 2.8 mm, horizontal FOV 107°, vertical FOV 57°, diagonal FOV 129° 4 mm, horizontal FOV 86°, vertical FOV 47°, diagonal FOV 102° 6 mm, horizontal FOV 55°, vertical FOV 29°, diagonal FOV 65° Lux sensitivity - minimum 0.2 Lux at color, minimum 0.05 Lux at Black & White, 0.0 Lux (IR) Night Vision Distance minimum IR - 50m. Camera minimum Adjustment Angles - Pan : 350°, Tilt : 72°, Rotate : 350°. Power Supply : Support 12VDC & PoE, IP67, IK10 - Vandal Resistant. Built in micro SD/SDHC/SDXC card slot of minimum 128 GB, Built in microphone. minimum Input/Output - Audio in × 1, Audio Out × 1, Alarm in × 1, Alarm Out × 1. Image Settings : Rotate mode, saturation, brightness, contrast, sharpness, gain, white balance. Image Enhancements : Day/Night-Auto (ICR)/Color/Black & White, 3D Digital Noise Reduction, Automatic White Balance, Automatic Gain Control, Backlight Compensation, Highlight Compensation. Events : Privacy Masking, Motion detection, Scene change detection, Face capture, Video tampering, audio exception detection, Region entrance detection, Region exiting detection. Operating temperature ( -30 to 60° C ) . Security - User account and password protection, HTTPS, IP filter, IEEE 802.1X, digest authentication, user access log, TLS1.2, AES - 256, SSH/Telnet closed, FTP disabled. Protocol - DHCP, UDP, HTTP, HTTPS, NTP, DNS, RTP, RTSP, SMTP, SSL/TLS, TCP/IP, Secure Real-Time Transport Protocol (SRTP), Bonjour, SNMP and Secure shell (SSH) supported protocol. RoHS, WEEE, ISO-14001 and REACH compliant, UL/EN OR equivalent BIS/TECH/STQC or any indian standards as applicable, CE, FCC certified. duly erected in position on wall/ceiling/false ceiling/provided pole (mounting height not more than 5 meter) etc with all accessories etc complete as per specification no. CCTV-CAM.

38

-

-

... More
Supplying, installing, testing & commissioning of 64/80 Ch Network Video Recorder (NVR), suitable connect Min. 80 IP Cameras, up to 5 Megapixel Resolution, with HDMI 1/VGA 1 and HDMI 2/VGA 2 outputs provided, Atleast one HDMI output of 4K resolution, atleast one VGA output with output up to 1920 × 1080, Support H.265 or higher, H.264, MJPEG, Supports Redundant Dual Power, Incoming Bandwidth 320 Mbps with minimum 8 SATA Hard Disks, ANR Technology, 8 SATA interfaces for 8 HDDs and capacity of each HDD up to 8TB, minimum 02 USB port, Alarm I/O 16/4, RJ-45 10/100/ 1000 Mbps selfadaptive Ethernet interface, support multi brand network Cameras, ONVIF conformance, Multiple network monitoring: Web viewer . support protocol TCP/IP, DHCP, DNS, DDNS, NTP, SADP, SMTP, NFS, iSCSI, UPnP™, HTTPS. RoHS, UL, CE, FCC certified. duly erected in provided U Rack with wiring connections, tagging and programming etc. complete as per specificationss no. CCTV-NVR

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.