Public Works Department Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Public Works Department - PWD Tender

Works
Building Construction
Electrical Works
Eprocure
Opening Date15 Oct 2024
Closing Date29 Oct 2024
Tender Amount₹ 66,15,33,352 
Notes
Download

Costs

  • EMD

    ₹ 33,08,000
  • Document Cost

    ₹ 3,540
  • Tender Fee

    ₹ 500

Summary

Construction Of Administrative Building For Zilla Parishad / Panchayat Samiti, Including

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Transportation of material obtained from debris of various sorts including necessary excavation/ loosing including loading, unloading and conveying and disposing as directed.

10862.88

-

-

... More
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) treatment by treating the backfill in immediate contact with foundation at the rate of 5 litres of emulsion concentrate of 1.0 percent of clorophyrifos per One Square Metre of vertical surface area covering 10 years guarantee on bond paper.

761.37

-

-

... More
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per One Square Metre of surface area covering ten yearsguarantee on bond paper.

3795.58

-

-

... More
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-I) to the soil along the external face of building by punching holes of 1.2 of 1.5 C.M. diametre about 30 -60 cm deep at 15 cm c/c as close to the wall as possible and to inject 0.5 percent of aldrin or clorophyrifos at the rate of 7.5 litres per hole and sealing the same with proper filling and covering 10 years guarantee on bond paper.

317.78

-

-

... More
Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete.

898.93

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate

1006.64

-

-

... More
Filling in plinth and floors with approved excavated material in 15cm. to 20cm. Layers including watering and compacting etc. complete.

381.1

-

-

... More
Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering andcompaction etc. complete.

6142.25

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. columns as per detailed designs and drawing or as directed including Steel centering formwork, cover blocks laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)

5006.09

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite/quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork,cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)

-

-

-

... More
Ground Floor

438.21

-

-

... More
First Floor

257.23

-

-

... More
Second Floor

257.23

-

-

... More
Third Floor

257.23

-

-

... More
Fourth Floor

257.23

-

-

... More
Fifth Floor

102.42

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite/quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)

-

-

-

... More
Ground Floor

461.6

-

-

... More
First Floor

221.88

-

-

... More
Second Floor

221.88

-

-

... More
Third Floor

221.88

-

-

... More
Fourth Floor

221.88

-

-

... More
Fifth Floor

50.05

-

-

... More
Providing and laying in situ / ready mix controlled grade of M25 of trap /granite /quartzite /gneiss metal for RCC works in cut off walls / curtain walls including necessary scaffolding, centering, compacting by vibrator, finishing and curing etc. complete. (with fully automatic micro processor based PLC with SCADA enabled with reversible drum type mixer/ concrete batch mix plant (pan mixer) with fine agreegates of required specifications ( VSI sand finely washed etc ), excluding reinforcement)

-

-

-

... More
Ground Floor

9.74

-

-

... More
First Floor

15.75

-

-

... More
Second Floor

15.75

-

-

... More
Third Floor

15.75

-

-

... More
Fourth Floor

15.75

-

-

... More
Fifth Floor

15.75

-

-

... More
Providing and laying Cast in situ/Ready Mixcement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)

-

-

-

... More
Ground Floor

29.6

-

-

... More
First Floor

53.57

-

-

... More
Second Floor

54.43

-

-

... More
Third Floor

49.39

-

-

... More
Fourth Floor

33.19

-

-

... More
Fifth Floor

4.39

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)

-

-

-

... More
Ground Floor

687.08

-

-

... More
First Floor

642.27

-

-

... More
Second Floor

615.34

-

-

... More
Third Floor

658.21

-

-

... More
Fourth Floor

642.27

-

-

... More
Fifth Floor

195.32

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap / quartzite/granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)

-

-

-

... More
Ground Floor

39.85

-

-

... More
First Floor

17.08

-

-

... More
Second Floor

17.08

-

-

... More
Third Floor

17.08

-

-

... More
Fourth Floor

17.08

-

-

... More
Fifth Floor

17.08

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap /granite / gneiss/ quartzite metal for R.C.C. arches with skew backs as per detailed design and drawings or as directed including steel centering, plywood/steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement, including cover block). Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed) With fine aggregate (Crushed sand VSI Grade)

-

-

-

... More
Ground Floor

2.17

-

-

... More
First Floor

11.01

-

-

... More
Second Floor

0.44

-

-

... More
Third Floor

0.44

-

-

... More
Fourth Floor

7

-

-

... More
Fifth Floor

40.47

-

-

... More
Providing and fixing during laying in RCC Slab rectangular 2 mm thick M.S. sheet fan hook box of size 180x100 mm with required depth with holes or notches as required, bottom and top sides of 1.6 mm M.S. sheet fixed with 3.5 mm dia. round headed screws together with 12 mm dia. M.S. bar bent to shape with hooked ends for fan hook andpainting to exposed surface

-

-

-

... More
Ground Floor

120

-

-

... More
First Floor

120

-

-

... More
Second Floor

120

-

-

... More
Third Floor

120

-

-

... More
Fourth Floor

120

-

-

... More
Fifth Floor

60

-

-

... More
Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.

-

-

-

... More
Ground Floor

602.97

-

-

... More
First Floor

145.28

-

-

... More
Second Floor

140.34

-

-

... More
Third Floor

144.33

-

-

... More
Fourth Floor

144.33

-

-

... More
Fifth Floor

51.15

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C.coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including steel centering, formwork, cover blocks, laying/pumping, compacting , curing , finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)

-

-

-

... More
Fifth Floor

7.52

-

-

... More
Providing and applying water proofing treatment using acrylic polymer modified cement based water proofing coating with fibre glass mesh mixing at the rate of powder to liquid (2:1) by weight covering 9 to 10 Square Metre /Kilogram with two coat using approved chemicals for masonry and concrete surface by brush covering 7 years guarantee on Stamp Papers etc. complete.

-

-

-

... More
Fourth Floor

2413.88

-

-

... More
Fifth Floor

797.44

-

-

... More
Providing and laying mechanical protective layer over water proofing membrane with cement screed plaster 1:5 after laying chicken mesh over membrane including curing etc. complete 20 mm thick with cost of chicken mesh etc. complete and covering 7 years guarantee on court stamp paper of Rs.100/- including necessary testing specified by Engineer (Prior permission of S.E. is necessary before inclusion of this item in estimate) (Note :- This item shall be executed over item One Number 5 of BD-J Water Proofing)

-

-

-

... More
Fourth Floor

2413.88

-

-

... More
Fifth Floor

797.44

-

-

... More
Providing water proof bedding for flooring of Bath and WC 25 mm thick in C.M. 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding testetc. complete.

-

-

-

... More
Ground Floor

118.05

-

-

... More
First Floor

149.07

-

-

... More
Second Floor

119.33

-

-

... More
Third Floor

134.01

-

-

... More
Fourth Floor

68.26

-

-

... More
Fifth Floor

9

-

-

... More
Providing waterproofing in W.C. and bath including brick bat coba in all position including providing and laying 12mm bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound @ 1Kilogram/per bag of cement laying brick bat coba of required thickness in cm 1:5 with waterproofing compound 1 Kilogram/bag of cement grouting and finishing the top layer with 20mm thick brick bedding in cm mortor 1:3 with waterproofing compound 1 Kilogram/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etc. complete.

-

-

-

... More
Ground Floor

35.43

-

-

... More
First Floor

44.74

-

-

... More
Second Floor

30.41

-

-

... More
Third Floor

40.21

-

-

... More
Fourth Floor

20.48

-

-

... More
Fifth Floor

2.7

-

-

... More
Providing fly ash brick masonry with conventional / I.S. type fly ash bricks in C.M. 1:6 in foundation and plinth including bailing out water manually striking joints, racking out joints watering and scaffolding etc. complete.

35.5

-

-

... More
Providing fly ash brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete

-

-

-

... More
Ground Floor

302.13

-

-

... More
First Floor

202.67

-

-

... More
Second Floor

195.47

-

-

... More
Third Floor

201.45

-

-

... More
Fourth Floor

220.09

-

-

... More
Fifth Floor

75.19

-

-

... More
Providing Autoclaved Aerated Concrete Block masonary of conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in superstructure including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972)

-

-

-

... More
Ground Floor

127.13

-

-

... More
First Floor

377.67

-

-

... More
Second Floor

334.77

-

-

... More
Third Floor

352.69

-

-

... More
Fourth Floor

296.55

-

-

... More
Fifth Floor

197.03

-

-

... More
Providing Second class fly ash brick masonry with conventional / I.S. type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of two bars of 6 mm diameter / two hoop iron strips 25 mm x 1.60 mm at every third course, properly bent and bounded at ends scaffolding raking out joints and watering etc.complete.

-

-

-

... More
Ground Floor

548.05

-

-

... More
First Floor

513.24

-

-

... More
Second Floor

487.69

-

-

... More
Third Floor

1010.66

-

-

... More
Fourth Floor

436.58

-

-

... More
Providing internal cement plaster 12mm thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffoldingand curing etc. complete.

-

-

-

... More
Ground Floor

1532.1

-

-

... More
First Floor

1166.86

-

-

... More
Second Floor

1168.75

-

-

... More
Third Floor

1181.8

-

-

... More
Fourth Floor

530.81

-

-

... More
Fifth Floor

359.7

-

-

... More
Providing internal cement plaster 20mm thick in Single coats in cement mortar 1:5 without neeru finish, to concrete, brick surface, in all positions including scaffolding andand curing etc. complete.

-

-

-

... More
Ground Floor

1053.23

-

-

... More
First Floor

1166.86

-

-

... More
Second Floor

1168.75

-

-

... More
Third Floor

1181.8

-

-

... More
Fourth Floor

1222.3

-

-

... More
Fifth Floor

359.7

-

-

... More
Providing and applying Texture plaster with finishing with texture material of approved make in 3 to 4 millimeter thickness on previously plastered surface, including Plaster Groove 6mm thickness or Tape Grooves 35 to 45 mm thickness or as required, in all position including preparing the surface, scaffolding etc. complete.

-

-

-

... More
Ground Floor

1053.23

-

-

... More
First Floor

1166.86

-

-

... More
Second Floor

1168.75

-

-

... More
Third Floor

1181.8

-

-

... More
Fourth Floor

1222.3

-

-

... More
Fifth Floor

359.7

-

-

... More
Providing and applying gypsum plaster ( with Gypsum material ) with finishing with gypsum material in 10 to 13 millimeter thickness to previously plastered surface / or on newly brick surface ( Excluding rough cast plaster ) in all position including preparing andFinishing the surface scaffolding etc.complete.

-

-

-

... More
Ground Floor

1275.87

-

-

... More
First Floor

2636.18

-

-

... More
Second Floor

2323.97

-

-

... More
Third Floor

2982.41

-

-

... More
Fourth Floor

2083.46

-

-

... More
Fifth Floor

1039.18

-

-

... More
Providing and applying impression 24 carrat Luxury paint of approved make & approved brand Emulsion paint to interior walls and ceilings of approved quality, colour and shade to new surface in two coats, including sub surface prparation by Acrylic putty and Acrylic primer coats including scaffolding, preparing the surface. etc. complete(Low VOC).

-

-

-

... More
Ground Floor

2618.2

-

-

... More
First Floor

2636.18

-

-

... More
Second Floor

2323.97

-

-

... More
Third Floor

2982.41

-

-

... More
Fourth Floor

2083.46

-

-

... More
Fifth Floor

1039.18

-

-

... More
Providing and applying antipeel paint of approved make & approved brand exterior Emulsion paint of approved quality, colour and shade to old and new surface in two coats, including exterior acrylic primer coat, scaffolding, preparing the surface etc. complete (HeatReflective Paint).

-

-

-

... More
Ground Floor

1915.19

-

-

... More
First Floor

1166.86

-

-

... More
Second Floor

1168.75

-

-

... More
Third Floor

1181.8

-

-

... More
Fourth Floor

1222.3

-

-

... More
Fifth Floor

359.7

-

-

... More
Providing and Fixing 30 MM thick BOTH SIDE PRELAMINATED SOLID PANEL PVC DOOR SHUTTER consisting of frame made out of M.S tubes of 19 guage thickness and, size 19 x 19 mm for styles and 15 x15 mm for the top and bottom rails, M.S frame shall have a coat of metel primer of approved make and manufacture. M.S frame shall be covered with heat mouled PVC 'C' channel made from 5 mm (+/0.25) thick prelaminated sheet of density 600 Kilogram/cbm ,of size 30mm thickness 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45? angle on either side forming stiles ; and 5 mm thick ,95 mm wide PVC sheet out of which 75 mm shall be falt and 20 mm shall be tapered in 45 on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be falt and 20 mm shall be tapered on both sides to form lock rail.Top,bottom and lock rail shall be provided either side of the panel. An additional 5 mm (+/0.25) thick PVC strip of 20 mm width is to be stuck on the bottom side of the ' c ' channel prelaminated paneling of 5 mm (+/0.25) thick PVC sheet to be fitted inside the M.S. frame welded/ sealed to the styles and rails with 5 mm (+/0.25) x 30 mm PVC sheet beading on either side and joined together with solvent cement adhesive etc ,10 mm thickness (5 mm (+/0.25) x 2 nos ) 20 mm wide cross PVC sheet as gap insert for the rail and bottom rail. Door to be fixed to frames with 3 nos M.S.powder coated but hinges of size 100 mm x 25MM x 2mm using 32 mm long steel screws drilled suitable to pass through both the walls of the M.S tube. Other hardwares

-

-

-

... More
Ground Floor

23.63

-

-

... More
First Floor

39.69

-

-

... More
Second Floor

37.8

-

-

... More
Third Floor

42.53

-

-

... More
Fourth Floor

18.9

-

-

... More
Providing and fixing M40 grade thick vibrated pull cast or similar type concrete frame with chamfer conforming to I.S. 65241983 having 6 mm dia. bars 3 Nos. And stirrups @250 mm c/c and fixing in wall with 6 Nos of hold fast of 12 mm dia bars 500 mm long including primer and oil painting etc, complete) frame size 60 mm x 100 mm .

-

-

-

... More
Ground Floor

46.6

-

-

... More
First Floor

103.4

-

-

... More
Second Floor

88.1

-

-

... More
Third Floor

159.5

-

-

... More
Fourth Floor

56.7

-

-

... More
Fifth Floor

25.5

-

-

... More
Solid Core Flush door Single leaf Providing and fixing factory made solid core flush door in single leaf 35 mm thick, decorative types, of exterior grade, as per detailed drawings, conforming to I.S.:2202 - 1962 (Revised) with approved face veneers on both faces with/without glazing and venetians in the positions shown on the drawings or as directed, all necessary beads, moulding and lipping, holdfasts, mat finish stainless steel fixtures fastenings , finishing with french-polish/ waxing complete. (without door frame).(Sample to be got approved from Ex.Engineer before use) Commercial Hard Wood shutter

-

-

-

... More
Ground Floor

32.64

-

-

... More
First Floor

59.34

-

-

... More
Second Floor

42.24

-

-

... More
Third Floor

74.37

-

-

... More
Fourth Floor

29.61

-

-

... More
Fifth Floor

3.78

-

-

... More
Providing and fixing Country cut teak wood double or single leaf panelled shutters, 35 mm thick style top and freze rail 95 x 35 thick with lock and bottam rail 195 x 25 mm thick and panels without ventilator as per detailed drawing excluding the door frame, stainless steel fixtures and fastening and finishing the wood work with oilpainting 3 coats complete

-

-

-

... More
Ground Floor

115.5

-

-

... More
First Floor

132

-

-

... More
Second Floor

88.8

-

-

... More
Third Floor

99.6

-

-

... More
Fourth Floor

110.4

-

-

... More
Fifth Floor

55.2

-

-

... More
Providing and fixing Country teak wood Four leaf paneled shutters, 35 mm thick style and rail and 25 mm thick panels without ventilator as per detailed drawing excluding the door frame, stainless steel fixtures and fastening and finishing the woodwork with oil painting 3 coats complete

-

-

-

... More
Ground Floor

7.2

-

-

... More
First Floor

7.2

-

-

... More
Second Floor

7.2

-

-

... More
Third Floor

7.2

-

-

... More
Fourth Floor

7.2

-

-

... More
Fifth Floor

7.2

-

-

... More
Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete

-

-

-

... More
Ground Floor

1.87

-

-

... More
First Floor

2.36

-

-

... More
Second Floor

1.62

-

-

... More
Third Floor

1.53

-

-

... More
Fourth Floor

1.82

-

-

... More
Fifth Floor

1.1

-

-

... More
Providing and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/ One Square Metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete.

-

-

-

... More
Ground Floor

210.46

-

-

... More
First Floor

277.29

-

-

... More
Second Floor

285.66

-

-

... More
Third Floor

259.11

-

-

... More
Fourth Floor

172.26

-

-

... More
Fifth Floor

23.31

-

-

... More
Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 mm with lock plate of 3.15 mm thickness reinforced with 35 x 35 x 5 mm angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65 mm and 3.15 mm respectively with hold fast arrangements,M.S. Bracket plate 300 x 300 x 3.15 mm minimum size and shape with square bar, suspension shaft of minimum 32 mm diameter, hood cover of M.S. sheet not less than 0.9 mm thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc. complete. (I.S. 62481979) (With mechanical gear)

-

-

-

... More
Ground Floor

39.17

-

-

... More
First Floor

8.7

-

-

... More
Providing and fixing of factory made uPVC casement window / Fixed Window & Casement Door (White Colour) comprising uPVC multi-chambered frame, Sash, & Mullion with wall thickness of 2.3mm (+-0.2 mm ), duly reinforced with G.I. section 1.5 mm, wherever required. uPVC window & door profile shall be made in India & shall conform to BS EN 12608 and other standards as mentioned below: S.No. Name of the test Test Method Specified Parameter 1 Tensile Impact Strength ISO 8256 - more than 700Kj/m2 2 Vicat Softening Temperature EN ISO – 306 Shall not be 750C 3 Charpy Impact Strength EN ISO – 179-2 Shall not be 20KJ/m2 4 Flexural Modulus Elasticity EN ISO – 178 Shall not be 2200 N/mm2 5 Mean Breaking Stress for welded corner (a) For the tensile bending test EN – 514 Shall not be 25 N/mm2 (b) For the compression bending test Shall not be 30N/mm2 6 Heat Reversion Test IS:4985-2000 Shall not be 2.0 % 7 Surface Spread of flame BS : 476 - Part 7 Classification 1 8 Ignitability Evaluation BS : 476 - Part 5 'P' Not easily ignitable 9 Tensile modulus ASTM D 638 Shall not be 35 MPa 10 Shear Modulus ASTM D 732 Shall not be 220 MPa 11 Tensile Strength EN ISO 527 Shall not be 30 MPa. All corners of frame and sash will be fusion welded. Mullion shall be welded / screwed. EPDM / TPE Gasket shall be provided in all frame, sash & mullion, wherever necessary.Thereafter, 5 mm Float Annealed glass shall be provided in the sash with the help of uPVC glazing bead and hardware, i.e., friction hinge & single point handle (in window) & 3D Hinges & Multipoint Lock (in door) shall be provided. Window / Door shall be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge. uPVC Window and Door Profiles are warranted for a period of ten (10) years against non-uniform discoloration, wrapping and rotting under general use. A)Casement Window (Big Series) frame of size 67 x 62 mm & Sash / Mullion of size 67 x 78 mm. One Square metre

-

-

-

... More
Ground Floor

205.51

-

-

... More
First Floor

267.84

-

-

... More
Second Floor

272.16

-

-

... More
Third Floor

246.96

-

-

... More
Fourth Floor

165.96

-

-

... More
Fifth Floor

21.96

-

-

... More
Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 mm x 1.22 mm box type, 5 mm thick sheet glass louvers, of approved quality etc. complete.

-

-

-

... More
Ground Floor

6.75

-

-

... More
First Floor

11.25

-

-

... More
Second Floor

13.5

-

-

... More
Third Floor

12.15

-

-

... More
Fourth Floor

6.3

-

-

... More
Fifth Floor

1.35

-

-

... More
Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing inC.M. 1:3 curing and cleaning etc. complete.

-

-

-

... More
Ground Floor

641.27

-

-

... More
First Floor

921.65

-

-

... More
Second Floor

740.38

-

-

... More
Third Floor

847.81

-

-

... More
Fourth Floor

847.81

-

-

... More
Fifth Floor

316.3

-

-

... More
Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etc. complete.

-

-

-

... More
Ground Floor

603.29

-

-

... More
First Floor

877.02

-

-

... More
Second Floor

790.81

-

-

... More
Third Floor

823.73

-

-

... More
Fourth Floor

726.84

-

-

... More
Fifth Floor

189.46

-

-

... More
Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete.

-

-

-

... More
Ground Floor

288.42

-

-

... More
First Floor

19.35

-

-

... More
Second Floor

116.25

-

-

... More
Third Floor

116.25

-

-

... More
Fourth Floor

116.25

-

-

... More
Fifth Floor

116.25

-

-

... More
Providing and laying Antiskid Ceramic tiles of approved quality of size 30 cm x 30 cm and confirming to IS 15622-2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurrycleaning curing etc. complete.

-

-

-

... More
Ground Floor

114.66

-

-

... More
First Floor

152.11

-

-

... More
Second Floor

117.99

-

-

... More
Third Floor

128.53

-

-

... More
Fourth Floor

73.09

-

-

... More
Fifth Floor

9

-

-

... More
Providing and laying ceramic tiles having size 30 cm. x 45 cm. confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling withwhite/ colour cement slurry cleaning curing etc. complete.

-

-

-

... More
Ground Floor

477.7

-

-

... More
First Floor

613.75

-

-

... More
Second Floor

481.94

-

-

... More
Third Floor

523.66

-

-

... More
Fourth Floor

306.95

-

-

... More
Fifth Floor

36.12

-

-

... More
Providing and laying vitrified matt fininsh tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc.complete.

-

-

-

... More
Ground Floor

751.42

-

-

... More
First Floor

1818.97

-

-

... More
Second Floor

1895.54

-

-

... More
Third Floor

1762.13

-

-

... More
Fourth Floor

2048.1

-

-

... More
Fifth Floor

335.75

-

-

... More
Providing and laying vitrified matt finish tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc.complete.

-

-

-

... More
Ground Floor

137.88

-

-

... More
First Floor

187.19

-

-

... More
Second Floor

173.05

-

-

... More
Third Floor

187.8

-

-

... More
Fourth Floor

145.69

-

-

... More
Fifth Floor

26.73

-

-

... More
Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 mm x 450 mm size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 mm thick supports with kadappah top 35 to 40 mm thick and polished granite 16 to 20 mm top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 cm height and top granite of75 x 40 cm including cutting, opening for sink of required size in kadappah as well as granite etc. complete. (Platform top size 5.00 m x 0.60 m and height is 0.75 m)

9.48

-

-

... More
Providing, laying and fixing exterior grade fibrilling fibre reinforcement heavy duty designer cement concrete tiles for Flooring of approved colour and design 22 +/ -2 mm thick bayer colour pigmented as per IS ..1237 - 1980 having compressive strength more than 500 Kilogram/sq.cm reaffirmed in 2006 ,having wert transvrse strenghth of 3.5 / mm 2, water absorption less than 10 % abrasion / wear resistance less than 2 mm ,skid resistance more than 25.0 (ASTM:E303) and no fading as per DIN - 51094 of size 300 x 300 in plan / designed pattern on a bed of 1:4 cement mortar including cement float ,filling joints with neat cement slurry ,curing, polishing and cleaning etc. complete. For flooring.

207.9

-

-

... More
Providing and fixing machine cut mirror polished 18 mm to 20 mm thick telephone black granite / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone partition with full moulding the edges etc. complete . Both side polish

-

-

-

... More
Ground Floor

4.5

-

-

... More
First Floor

3.6

-

-

... More
Second Floor

3.6

-

-

... More
Third Floor

3.6

-

-

... More
Fourth Floor

3.6

-

-

... More
Providing and Fixing mat finish stainless steel (of 302 grade ) railing with top pipe of 50 mm dia. and vertical pipe of 38 mm dia at 0.60 m c/c or as required and horizontal pipes of 25 mm dia in three rows, all pipes of 2 mm thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 mm dia above newel post of 75 mm diameter etc. complete (Prior approval of sample and brand by Ex.Engineer is necessary before use)

-

-

-

... More
Ground Floor

60.31

-

-

... More
First Floor

27.72

-

-

... More
Second Floor

27.72

-

-

... More
Third Floor

27.72

-

-

... More
Fourth Floor

27.72

-

-

... More
Fifth Floor

27.72

-

-

... More
Providing and fixing 90 cm x 60 cm Marble plate engraving 10 cm. height letter, figures including painting the lefters/figures with approved colour and shade complete

2

-

-

... More
Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc.complete

-

-

-

... More
Ground Floor

485.12

-

-

... More
First Floor

327.03

-

-

... More
Second Floor

327.03

-

-

... More
Third Floor

327.03

-

-

... More
Fourth Floor

327.03

-

-

... More
Fifth Floor

327.03

-

-

... More
Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directedetc. complete.

-

-

-

... More
Ground Floor

83.36

-

-

... More
First Floor

104.34

-

-

... More
Second Floor

70.8

-

-

... More
Third Floor

46.97

-

-

... More
Fourth Floor

42.96

-

-

... More
Fifth Floor

32

-

-

... More
Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directedetc. complete.

-

-

-

... More
Ground Floor

88.36

-

-

... More
First Floor

104.34

-

-

... More
Second Floor

70.8

-

-

... More
Third Floor

46.97

-

-

... More
Fourth Floor

42.96

-

-

... More
Fifth Floor

32

-

-

... More
Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.

-

-

-

... More
Ground Floor

83.36

-

-

... More
First Floor

104.34

-

-

... More
Second Floor

70.8

-

-

... More
Third Floor

46.97

-

-

... More
Fourth Floor

42.96

-

-

... More
Fifth Floor

32

-

-

... More
Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directedetc. complete.

-

-

-

... More
Ground Floor

112.4

-

-

... More
First Floor

109.2

-

-

... More
Second Floor

117.6

-

-

... More
Third Floor

151.2

-

-

... More
Fourth Floor

67.2

-

-

... More
Fifth Floor

36.8

-

-

... More
Providing and fixing on walls /ceiling/ floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directedetc. complete.

-

-

-

... More
Ground Floor

102.4

-

-

... More
First Floor

109.2

-

-

... More
Second Floor

117.6

-

-

... More
Third Floor

151.2

-

-

... More
Fourth Floor

67.2

-

-

... More
Fifth Floor

36.8

-

-

... More
Providing and fixing on walls/ ceiling/ floor 50 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete.

-

-

-

... More
Ground Floor

102.4

-

-

... More
First Floor

109.2

-

-

... More
Second Floor

117.6

-

-

... More
Third Floor

151.2

-

-

... More
Fourth Floor

67.2

-

-

... More
Fifth Floor

116.8

-

-

... More
Providing and laying in trenches 15 mm dai. CPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc.etc. complete.

59

-

-

... More
Providing and laying in trenches 20 mm dai. CPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.

69

-

-

... More
Providing and laying in trenches 25 mm dai. CPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc.etc. complete.

116

-

-

... More
Providing and laying in trenches 32 mm dai. CPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.

78

-

-

... More
Providing and laying in trenches 40mm dai. CPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.

59

-

-

... More
Providing and laying in trenches 50mm dai. CPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc.etc. complete.

55.5

-

-

... More
Providing and fixing screw down for 32 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete.

-

-

-

... More
Ground Floor

11

-

-

... More
First Floor

10

-

-

... More
Second Floor

10

-

-

... More
Third Floor

10

-

-

... More
Fourth Floor

10

-

-

... More
Fifth Floor

3

-

-

... More
Providing and fixing screw down for 40 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete.

-

-

-

... More
Ground Floor

11

-

-

... More
First Floor

10

-

-

... More
Second Floor

10

-

-

... More
Third Floor

10

-

-

... More
Fourth Floor

10

-

-

... More
Fifth Floor

2

-

-

... More
Providing and fixing screw down for 50 mm dia. wheeled stop tap of brass including necessary sockets/ union nut complete.

-

-

-

... More
Ground Floor

11

-

-

... More
First Floor

10

-

-

... More
Second Floor

10

-

-

... More
Third Floor

10

-

-

... More
Fourth Floor

10

-

-

... More
Fifth Floor

4

-

-

... More
Providing and fixing 15 cm rigid PVC Nahani trap including PVC grating ,bend,connectingpiece of UPVC pipe up to the outside face of wall ,making the good damaged surface and testing etc. complete

-

-

-

... More
Ground Floor

32

-

-

... More
First Floor

39

-

-

... More
Second Floor

28

-

-

... More
Third Floor

36

-

-

... More
Fourth Floor

16

-

-

... More
Fifth Floor

5

-

-

... More
Providing and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete.

-

-

-

... More
Ground Floor

50

-

-

... More
First Floor

78

-

-

... More
Second Floor

28

-

-

... More
Third Floor

36

-

-

... More
Fourth Floor

16

-

-

... More
Fifth Floor

5

-

-

... More
Providing and fixing C.P. a 2-Way BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge.

-

-

-

... More
Ground Floor

26

-

-

... More
First Floor

39

-

-

... More
Second Floor

28

-

-

... More
Third Floor

36

-

-

... More
Fourth Floor

16

-

-

... More
Fifth Floor

5

-

-

... More
Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe andwith necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete.

-

-

-

... More
Ground Floor

83.36

-

-

... More
First Floor

104.34

-

-

... More
Second Floor

70.8

-

-

... More
Third Floor

93.94

-

-

... More
Fourth Floor

42.96

-

-

... More
Fifth Floor

32

-

-

... More
Providing and fixing white wash basin with half pedestal of size 515mmX615mmX460mm including pillar cock auto-closing system CP angular stop cock long thread of approved make continental including S.S. bottle trap of necessary pipeconnection upto the outside face of the wall.

-

-

-

... More
Ground Floor

27

-

-

... More
First Floor

39

-

-

... More
Second Floor

28

-

-

... More
Third Floor

18

-

-

... More
Fourth Floor

16

-

-

... More
Fifth Floor

5

-

-

... More
Providing and fixing 1st class white glazed earthenware Orissa Type W.C. Pan 580 mm dia including P or S trap cast iron soil and vent pipe upto the outside face of the wall (1:5:1 0) cement concrete bedding 15 mm thick, 10 liter P.V.C. flushing cistern with allnecessary pipe connection etc. complete.

-

-

-

... More
Ground Floor

6

-

-

... More
First Floor

6

-

-

... More
Second Floor

4

-

-

... More
Third Floor

5

-

-

... More
Fourth Floor

3

-

-

... More
Fifth Floor

1

-

-

... More
Providing and fixing white european type wall-hung, Size 360mm x 360mm x 575 mm with flush valve having flow rate up to 6.0 Litr/Minute of Jaquar/Cera/Hindware/Perryware or equivalent make including PVC soil pipe, vent pipe upto outside face of wall, 100mm dia PVC plug bend inlet pipe all fittings,cutting & making good walls, floors etc as directed by Engineer in charge.( Make shall conform to manufacturer's Green product and shall got approved from the Engineer In Charge.)

-

-

-

... More
Ground Floor

25

-

-

... More
First Floor

22

-

-

... More
Second Floor

15

-

-

... More
Third Floor

17

-

-

... More
Fourth Floor

9

-

-

... More
Fifth Floor

3

-

-

... More
Providing and fixing white glazed urinal with Pressmatic auto closing valve having flow rate up to 4.0 Litr/Minute of Jaquar/Cera/Hindware /Perryware or equivalent make withP.V.C. waste pipe with fitting arrangement etc.complete as directed by Engineer in charge.( Make shall conform to manufacturer's Green product and shall got approved from the Engineer In Charge.)

-

-

-

... More
Ground Floor

16

-

-

... More
First Floor

15

-

-

... More
Second Floor

10

-

-

... More
Third Floor

16

-

-

... More
Fourth Floor

8

-

-

... More
Fifth Floor

2

-

-

... More
Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for thegully trap.

24

-

-

... More
Providing , laying and fixing ,jointing Eco- drain 110 mm SN 8 Nu- Drain Upvc pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees, coupler, etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated material etc. complete.

-

-

-

... More
Ground Floor

130

-

-

... More
First Floor

195

-

-

... More
Second Floor

140

-

-

... More
Third Floor

180

-

-

... More
Fourth Floor

80

-

-

... More
Fifth Floor

25

-

-

... More
Full Height Partitions in Glass finish - Providing and Fixing 80mm to 85mm thick Full height Double Skin partition up to 3 mtr height with All visible sections in Anodized / Powdercoated finish. Made up of Frames and Tiles. Frame construction In combinaton of Aluminium Rails and Bottom ,Center and Top members, Connected with 2 way Round Shape Post , 3way Post , 4 way Post made up of Aluminium Extruded and Tiles in 5mm thk. Non Toughened Glass on both side. With all the Joints in the partitions covered with PVC extrusions to provide better sound Proofing. Tiles to be separated 55mm from each other to provide adequate space for drawing cables for electric, data and telephone with proper facility for fixing electrical and data switch plates. as per design and drawing.

-

-

-

... More
Ground Floor

58.04

-

-

... More
First Floor

58.04

-

-

... More
Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 600mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2and curing etc. complete.

100.52

-

-

... More
Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and airtightC. I. cover of 75Kilogramwith lid and frame fixed in cement concrete.

15

-

-

... More
Providing and constructing Brick Masonry Inspection Chamber 90cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W.pipes, Brick Masonry, plastering from inside and C.I. lid cover of 75Kilogramwith lid and frame fixed in cement concrete.

19

-

-

... More
Providing soak pit of size 120cm x 120cm x 120cm including excavating and filling with brick-bats.

2

-

-

... More
Providing and fixing H.D.P container one piece moulded water tank made out of low density polythyler and built corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacityabove 1000 to 20,000 litres

-

-

-

... More
Fifth Floor

2000

-

-

... More
RWH - Recharge PitProviding and constructing recharge pit of 2.0m deep and 1.0m dia of pre-cast RCC rings with 6.5" dia x 25m deep borewell at the floor of recharge pit including installation of combination of solid/perforated PVC casing pipe wrapped around with netlon mesh including 300mm thick sidefilling around outside of RCC rings (annular space) with 40mm size boulders including filling of recharge pit up to 0.5m depth with 25-75mm clean washed gravels from bottom up followed by 0.5m depth of 10- 25mm of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) media layer including covering with RCC slab, manhole frame & cover, PVC rungs, PVC end- caps, fittings etc. including arrangement for inlet & outlet pipe excavation & backfilling as shown in the drawing.The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical

1

-

-

... More
Providing & Fixing in position, 12mm wp Ply wood & 1.5mm laminate panels above the fabricated frame on one side , as per Architectural & Acoustical Design & Instructions & Complete in all aspects. including all materials labour,finishing etc complete

-

-

-

... More
Ground Floor

73.71

-

-

... More
First Floor

102.22

-

-

... More
Second Floor

90.45

-

-

... More
Third Floor

91.97

-

-

... More
Fourth Floor

33.07

-

-

... More
Providing and laying in place 300mm x 300mm x 9.8mm vitrified tactile warning and directional tiles of the approved brand, make and colour inside the buildings at in all corridors and lobbies, level differences etc. as per accessibility standards and as per the installation instructions prescribed by the manufacturer including zarri making wherever required and finishing including grouting the joints with white cement with matching pigments etc. up to the satisfaction of the engineer in charge complete.

-

-

-

... More
Ground Floor

46.49

-

-

... More
First Floor

60.74

-

-

... More
Second Floor

61.63

-

-

... More
Third Floor

63.96

-

-

... More
Fourth Floor

63.96

-

-

... More
Design, supply, fabrication and fixing acrylic multilingual Braille (raised dots) signboards of size 6"x 9" for room titles, designed as per the drawings issued and having 4mm thick blue acrylic base plate with Upper Case San Serif words made of white acrylic non glare cut out letters of height 15mm raised not less than 0.8mm above base plate and the equivalent word/s written in Hindi with Devnagri non glare acrylic letters of height 15mm raised not less than 0.8mm above base plate. Grade 2/ Grade 1 Braille to be integral with the sign face and be raised 0.5mm above base plate.Each signboard to be fixed as per manufacturers specifications on the wall adjoining the respective room door at a height of 1200mm from FFL and as per the directions by the engineer in charge.

-

-

-

... More
Ground Floor

16

-

-

... More
First Floor

20

-

-

... More
Second Floor

14

-

-

... More
Third Floor

16

-

-

... More
Fourth Floor

8

-

-

... More
Grab bars-Providing SS grab bars set for accessible toilets comprising of 4 nos. Grab bars as specified below.(1 nos. wing grab bar + 1 nos. L shaped grab bar + 2 nos. straight grab bars = 1 typical set) 27a) Swing grab bar (1 NOS) Providing a S.S. 304 SWING HANDICAP GRAB BAR - 700 mm and of DIA: 32MM and thickness 1.5mm of the roved brand and make. 27b) L Shaped grab bar (1 NOS) Providing S.S. 304 L SHAPED DISABLED GRAB BAR of IZE-600MM (H) X 600MM (D) and 32MM DIA. and thickness mm of the approved brand and make. 27c) Straight grab bar (2 NOS) Providing S.STEEL 304 GRAB RAIL (600 MM),32MM DIA. and thickness 1.5mm of the approved brand and make.

2

-

-

... More
Providing and installing bio digester unit based on DRDO technology made of fibre reinforced plastic (FRP) having composition and following technical specifications and including necessary pipe and accessories up to 3 meter length, excluding the necessary excavation for installing the bio digester. Percentage of fibre glass (glass content in fibre glass should be minimum 30%): -33.33% Percentage of polyester resin: - 66.67% Water absorption (as per ASTM):-0.30% Flammability as per ASTM Tensile strength:-115 MPA Specific Gravity at 25 degree centigrade 1.45 Izod impact strength:-65KJ/M2 Heat defection/distort temperature:-65deg C Corrosion resistance (Non Corrosive) fitted with Inlet pipe size rigid PVC: -100mm Outlet pipe size rigid PVC:-80mm Gas outlet rigid PVC with Valve: 20mm Bacteria immobilization PVC mattes (on all partition) With DRDO TOT licensee and latest batch certificate(month & year of supply) and capacity as below i) Up to 200 user size (4mx2.0mx1.25m), Capacity of Biodigester:-10000 liters, Area of top, bottom and side walls: - 31.00 sq.m, Area of partition walls: 10.00sq.m, Total weight of FRP: - 462.60 Kilogram, Bacteria inoculums quantity: - 3400 liters, Minimum thickness of side walls / top and bottom: 7mm, One Number of inside partitions: - 4, Minimum thickness of partition wall: 4mm

1

-

-

... More
Supply and Installation of Dpi Flux translucent roof with standing seam multicell polycarbonate panel system. The system with complete assembly of co extruded UV protected multicell panels incorporated into a complete system. Co-extruded UV protected polycarbonate panel system of min 16 mm thick of 1200mm (min.) width with angular daylighting concept. Panels shall have minimum seven layers in a truss bridge design for higher flexibility & strength. Panels with opaque and translucent clear combination as per required lux level and design requirements with all fixing accessories to ensure best performance for wind uplift, vibration, oil canning and visual appearance. Panels shall have an additional IR Blocking features for enhance thermal comfort. Panels shall be manufactured with vertical standing seam at both sides of the panel. Panels shall be fixed on Purlin with snap on connectors with double tooth grip lock locking mechanism and will be secured on MS structure (will be paid Separately) with 3 One Numbers self- drilling screws & trapezoid SS fasteners holding the base of the standing seam offering best stability having a pull-out load of min. 7000N (7KN) tested as per ISO 6892:1998 and IS 1608: 2005, as per design requirement. Panels must satisfy Dart drop impact test as per IS 14443-97 shall show no sign of breakage on Polycarbonate sheets which have been exposed to UV for a min. of 500 Hours as per ASTM G 155. Panels shall not have Yellowness Index as per ASTM D 1925 of 15 units when tested on a sample exposed to UV for 500 Hours as per ASTM G 155. U value shall not be more than 1.9 W/m2K as per EN ISO 10077-2:2018. Panel shall be with additional End cap/Aluminium U/F profile/ Glazing Bar for ends as required. Panel shall be fixed over MS structural steel/MS purlin (paid separately) conforming to the detail technical specifications as per approved architectural drawings. Trained and factory authorized labour with supervision to complete the entire panel installation as per drawing & direction of the engineer in charge. Colour: As per approval The 16mm thick panels shall be used for a roofing height of upto15 mtrs.

256.87

-

-

... More
Providing structural steel work in hollow section of various thickness and sizes in square, rectanular and round shape from 25mm to 450mm section as per IS 4923 YST 310 Grade produced from iron ore and blast furnace route etc. as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted/bolted/ welded connections and painting complete.

-

-

-

... More
Ground Floor

22.4

-

-

... More
Fifth Floor

6.42

-

-

... More
Providing and fixing Jodhapur Sand Stone of approved quality vein & colour for Baluster for Railing /Balcony, of size 100 mm x 100 mm x 600 mm. As per drawing approved by Engineer in-charge / Architect. Including cutting, dressing, machine / hand polish to surface, embossing, carving, grooving, mural work, installation and grinding, scaffolding, hoisting, erecting, fixing by mechanical jointing along with approved adhesive (like Adeldite), cement slurry and making level surface by cement mortar 1:3 before fixing, transportation of all materials up to site of work, filling of joints, cleaning, applying Anti-Moss treatment on surfaces of stone with specified chemical approved by Engineer in-charge including all material, labour, lead and lift etc.. complete.

-

-

-

... More
Ground Floor

482

-

-

... More
First Floor

180

-

-

... More
Second Floor

180

-

-

... More
Third Floor

180

-

-

... More
Fourth Floor

460

-

-

... More
Fifth Floor

280

-

-

... More
Providing and fixing Jodhapur Sand Stone of approved quality vein & colour for Top & Bottom Rail for stone railing of size 150 mm X 150 mm. As per drawing approved by Engineer in-charge / Architect. Including cutting, dressing, machine / hand polish to surface, embossing, carving, grooving, mural work, installation and grinding, scaffolding, hoisting, erecting, fixing by mechanical jointing along with approved adhesive (like Adeldite), cement slurry and making level surface by cement mortar 1:3 before fixing, transportation of all materials up to site of work, filling of joints, cleaning, applying Anti-Moss treatment on surfaces of stone with specified chemical approved by Engineer in-charge including all material, labour, lead and lift etc.. complete.

-

-

-

... More
Ground Floor

165

-

-

... More
First Floor

72

-

-

... More
Second Floor

72

-

-

... More
Third Floor

72

-

-

... More
Fourth Floor

156

-

-

... More
Fifth Floor

84

-

-

... More
Providing and fixing Jodhapur Sand Stone of approved quality vein & colour for newel post for Railing of staircase, of size 200 mm x 200 mm x 900 mm. As per drawing approved by Engineer in-charge / Architect. Including cutting, dressing, machine / hand polish to surface, embossing, carving, grooving, mural work, installation and grinding, scaffolding, hoisting, erecting, fixing by mechanical jointing along with approved adhesive (like Adeldite), cement slurry and making level surface by cement mortar 1:3 before fixing, transportation of all materials up to site of work, filling of joints, cleaning, applying Anti-Moss treatment on surfaces of stone with specified chemical approved by Engineer in-charge including all material, labour, lead and lift etc.. complete.

-

-

-

... More
Ground Floor

6

-

-

... More
First Floor

12

-

-

... More
Second Floor

12

-

-

... More
Third Floor

12

-

-

... More
Fourth Floor

16

-

-

... More
Fifth Floor

8

-

-

... More
Providing and fixing Jodhapur Sand Stone Cladding of 25 mm thickness to beam surfaces, wall , soffit and top of chajja of approved quality, vein & colour as per drawing. Fixing Yellow Jodhapur Sand Stone cladding by Hilti anchor bolt over on level surface, Including cutting, dressing, machine / hand polish to surface, embossing, carving, grooving, mural work, installation and grinding, scaffolding, hoisting, erecting, fixing by mechanical jointing along with approved adhesive (like Adeldite), cement slurry and making level surface by cement mortar 1:3 before fixing, transportation of all materials up to site of work, filling of joints, cleaning, applying Anti-Moss treatment on surfaces of stone with specified chemical approved by Engineer in-charge including all material, labour, lead and lift etc.. complete.

-

-

-

... More
Ground Floor

1208.68

-

-

... More
First Floor

1097.24

-

-

... More
FALSE CEILING SYSTEM GI METAL BIOGUARD CLIP IN PLAIN TILE WITH CARRIER SYSTEM 600 X 600MM Providing & Fixing horizontal level suspended ceiling comprising of GI Bioguard Clip-in Plain Tile 600x600mm (Nominal Size) tiles of 120 gsm galvanized steel as per IS 277 (2003) suitable for architectural finishes in 0.5mm thickness as per in IS:513 (1994) in Global white color with concealed suspension system having a bevelled edge of 3x3mm and height of 33mm on one side and 18mm on the other side. Tiles shall be flattened by precision leveller to minimize sag to less than 1/400mm. The tiles shall have double round pip of ɸ 2mm and ɸ 6mm for secure engagement and levelling respectively, along with swing down feature and special tabs to allow removal of tile to enable plenum access. The coated surface of the tile shall exhibit anti-microbial properties (eradication and inhibition of growth) and shall achieve up to 99.99% reduction in bacterial activity as per ISO22196:2011. The tile shall be electrostatically polyester powder coated using RoHS compliant powder having coating thickness ranging from 60-80 microns. The powder coating shall pass Salt Spray Test for 750 Hours as per ASTM B117, QUV –A Test for 1000hours as per ASTM G-154 – (Cycle – 1) and Humidity test for 1000hours as per DIN 50017. The powder coating shall have an adhesion of GT0 as per EN ISO 2409. The shade variation across batches shall be delta E1 using Excite/BYK Gardner instrument and gloss level of 25±5% at 60˚ as per ASTM D523. The tile shall have scratch, mar & abrasive resistance properties. The tile shall have a Light Reflectance of ≥ 63% in accordance to ASTM 1477-98 and Fire Performance of class 0/1 as per BS 476 Part 6 & 7 in module size of 600x600mm. SUSPENSION & INSTALLATION: Shall comprise of 3000mm long ‘C’ channels of 38H x 12W mm and 1mm thick spaced at 1200mm centre to centre securely fixed to the structural soffit using threaded rod (Approved make/Third Party Supply) connecting to C- channel hanger of 109x18.5x16.5mm at 1200mm C/C and anchor fastener (Approved make/Third Party Supply). The last hanger at the end of each C-channel shall not be greater than 600mm from the adjacent wall. Use a C-channel connector of 99.5x35x 9mm for splicing together two pieces of C-channels. 4000mm Clip-in bar of 16W x 40H mm

-

-

-

... More
Ground Floor

268.64

-

-

... More
First Floor

384.54

-

-

... More
Second Floor

446.73

-

-

... More
Third Floor

606.9

-

-

... More
Fourth Floor

623.48

-

-

... More
Fifth Floor

29.4

-

-

... More
Providing and fixing in position Gypsum board false ceiling with 12.5 mm thick Gypsum boards, screwed/fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should betaped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete.

-

-

-

... More
Ground Floor

286.44

-

-

... More
First Floor

303.65

-

-

... More
Second Floor

285.32

-

-

... More
Third Floor

259.65

-

-

... More
Fourth Floor

332.39

-

-

... More
Fifth Floor

93.4

-

-

... More
Anutone Pixel Square 3/8, 600x600x12.5mm, Square edge (T15 Grid system) : Providing & Fixing of Anutone pixel Square 3/8, perforated gypsum panels,white vinyl laminated front, backlined with white acoustical fleece, having 3x3mm square perforations @ 8.33mm pitch - 10% open area, of size 600x600x12.5mm, square edge having base density 700Kgs/m3, weight 8kg/m2 which is suspended by using 0.3mm thick Anutone Skelet TrelisT15 metal grid system. Anutone Skelet TrelisT15 metal grid system of 600x600mm module includes Anutone Skelet WA15W30 wall angle with unequal flanges of 15/19mm, length 3000mm, fixed along the perimeter of walls with the help of nylon sleeves and suitable fasteners at 300mm centers. Then suspend the Anutone Skelet MT15W36 MainT with flange width 15mm, height 32mm and length 3600mm, from the soffit slab with help of soffit cleat and wire rod with leveling spring clip at 1200mm centres. Anutone Skelet CT15W12 CrossT with flange width 15mm, height 26mm and length 1200mm is interlocked into the pre-cut slots in the Main T15 at 600mm centers in the perpendicular direction to the Main T15. Finally Anutone Skelet CT15W06 CrossT with flange width 15mm, height 26mm and length 600mm are interlocked into the precut slots in the CT15W12 CrossT in direction parallel to the Main T15 to result in 600x600mm module. Anutone pixel Square 3/8, square edge of size 595x595x12.5mm shall be placed into the grid size of 600x600mm. Technical Parameters : • Fire (Class) – 1 & P • Acoustics – NRC 0.75 • Thermal conductivity (W/mk)– na • Climate (°C, RH) – 50, 90 • Light reflectance (%) – 80 • Green (VOC, RC %) – Low, 25 Approved make :Hunter Douglas, Anutone, NLF Accoustic & orbit.

-

-

-

... More
Ground Floor

787.05

-

-

... More
First Floor

1720.67

-

-

... More
Second Floor

1616.78

-

-

... More
Third Floor

1471.34

-

-

... More
Fourth Floor

1883.57

-

-

... More
Fifth Floor

529.25

-

-

... More
Providing and fixing of Anutone Slats - made out of pinewood fibreboards, perforated wooden grooved slats L8-2 - (2mm grooves @ 8mm centers) / L16-2 - (2mm Slats @16mm pitch) / L32-2 - (2mm grooves @ 32mm centres) /L64-2 - (2mm grooves @ 64mm centers), backlined with acoustical fleece, tongue-groove edge for a seamless look, of lineal dimension size 300mm x 2440mm x 16mm thick having density 800Kg /m3, weight 10 Kgs/m2, installed by using wall Panelling system. The wall panelling system shall includes GI Wall channel(WC25) having thickness 0.45mm, length 3600mm, unequal flanges of 20 & 30mm and web of 25mm to be fixed along the perimeters of the wall with nylon sleeves and suitable fasteners at every 300mm centers. Main channels(MC45) having thickness 0.9mm, length 3600mm, equal flanges of 15mm and web 45mm from the soffit at every 1200mm centers with Suspender angle (SA25) having thickness 0.45mm, length 3600mm, unequal flanges of 25 & 10mm. GI Cross channel(CC25) having thickness 0.45mm, length 3600mm, knurled web of 50mm, depth of 25mm and equal flanges of 9.5mm is fastened to the Main channel (MC45) in the direction perpendicular to the Main Channel(MC45) at every 600mm centers. Aluminium core cross channel (CC18). Approved make :Hunter Douglas, Anutone, NLF Accoustic & orbit.

-

-

-

... More
Ground Floor

63.68

-

-

... More
First Floor

115.43

-

-

... More
Second Floor

50.47

-

-

... More
Third Floor

82.81

-

-

... More
Fourth Floor

32.22

-

-

... More
Providing & Fixing of Anutone Synth 50mm thick (1000 G SM Density) Thermally bonded (6 x 4 sheet), chemically free, eco-friendly, healthy-does not itch. It stays in position for lifetime, does not sag down in partitions and panelling, density fidelity assured. Finish : Polyfibre, Core : Polyfibre, Thickness (mm) : 50, Fire (Class) : IS-15061 / BS-3119, NRC : Upto 0.7, Thermal (W/mk) : 0.04, Climate (degree C, RH) : 49, 95, Light (%) : na, Green (VoC, RC%) : Low, 25. Approved make :Hunter Douglas, Anutone, NLF Accoustic & orbit.

-

-

-

... More
Ground Floor

63.68

-

-

... More
First Floor

115.43

-

-

... More
Providing & Fixing of acoustic wall panelling Consisting Soak Coard of selected colours as approved by Engineer in charge. Kerf edge Fabric wrapped wood fiber panels of size 600x1200x15mm having density 400Kgs/m3, weinglii4120ki/m2 installed by using GI strut system The GI strut work includes Cross channel having thickness 0.45mm, lenght 3600mm,knurled web50, depth 50mm and equal flanges of 13mm is fastened to Wall positioned horizontally in regular manner at 600mm centers. PVC Vinyl core UV treated HSpline having thickness 2mm and length 2400mm to be fixed perpendicular to the Cross channels at 600mm centers,Kerfed edge Fabric wrapped panels shall be then inserted into the H- spline against wall to perfact fit. Approved make :Hunter Douglas, Anutone, NLF Accoustic & orbit.

-

-

-

... More
Ground Floor

119.93

-

-

... More
First Floor

194.66

-

-

... More
Second Floor

167.47

-

-

... More
Third Floor

173.07

-

-

... More
Fourth Floor

67.55

-

-

... More
Providing and fixing of Perforated miniwave Cladding system manufactured of approved white color consisting of 270 mm wide, 14 mm deep Panels with a 19mm dia curved construction giving a corrugatedb construction of panel having length upto4 mtrs roll formed from 0.7 mm thick Aluminium Alloy for higher strength and good Roll forming characteristics. The Miniwave Panel shall be manufactured on high-speed high precision DALLAN COMBI multi stage roll formingsystem. The levelling of the coil to be achieved through ARKU SIX Hi configuration roller levelling process to ensure the flatness of the coil. Paints shall be coil coated on a continuous paint line, Double baked and roll formed for higher straight and good roll forming characteristics Panels shall be secured to the existing MS structure (M.S. structure to be paid separately) by means of screws at a centre-to-centre distance of 1000 mm and the next panel shall overlap to the previous panelmaintaining a uniform corrugation. Assembly of Miniwave is simple and fast. The panel fastening is made by means of rivet or screw on the flat part and hidden by snap "malefemale", directly on the support structure as per site requirement. The miniwave product manufacturer should have manufacturing plant in India to the promote Make In India product as per the directives of Approved make :Hunter Douglas, Anutone, NLF Accoustic & orbit.

-

-

-

... More
Ground Floor

42

-

-

... More
First Floor

49.08

-

-

... More
Second Floor

93.87

-

-

... More
Providing & fixing of of Anutone Subtex Nubby, steppe edge, Glassfibre core fully encapsulated ceiling tile of size 595x595x15mm having density 100- 120Kgs/m3, weight 1.5-1.8kg/m2 which is suspended by using 0.3mm thick and 15mm wide pre coated metal T15 grid system.The T15 Grid system of 600x600mm module shall include wall angle (WA15W30) with unequal flanges of size 14&20mm wide, length 3000mm, 0.43mm thick fixed along the perimeter of walls with the help of nylon sleeves and suitable fasteners at 300mm centers. Then suspend the Main T15 (MT15W36) having flange width 15mm, height 32mm and length 3600mm from the soffit with help of soffit cleat and wire rod with leveling spring clip at 1200mm c/c. Cross T15 (CT15W12) having flange width 15mm, height 32mm and length 1200mm is then interlocked into the pre-cut slots in the Main T15 at 600mm centers in the direction perpendicular to the Main T15. Finally Cross T15 (CT15W06) having flange width 15mm, height 32mm and length 600mm are then interlocked into the pre cut slots in the 1200mm Cross T15 at 1200mm centers and in direction parallel to the Main T15. Subtex Nubby steppe edge of size 595x595x15mm thick shall be placed into the grid size of 600x600mm. Ensure arrow Approved make :Hunter Douglas, Anutone, NLF Accoustic & orbit.

-

-

-

... More
Ground Floor

46.33

-

-

... More
First Floor

137.66

-

-

... More
Second Floor

65.85

-

-

... More
Third Floor

54.81

-

-

... More
Fourth Floor

49.36

-

-

... More
Fifth Floor

49.38

-

-

... More
Providing & Fixing of 300C wooden finish Perf + NWT (0.7 NRC) 2.0 mm diameter 5mm c/c pasted with aproved color NWT corrosion resistant Alluminium Magnesium Alloy metal ceiling Hunter Douglas consisting of panel 300m wide x 30 mm deep x 0.7 mm thick with bevel edge having panel length upto 6 mtrs. coil coated on a continuous paintlien, Double baked and roll formed for higher straight and good roll forming characteristics with 21% perforation. The panel ends are raised upto 29 mm . The panel about each other with a narrow V groove. Panel shall be clipped to a backed enamelled aluminium panel carrier of 41.5 mm wide x 62 mm deep x 0.95 mm thick in standard length of 5 mtrs. made of double baked enamelled aluminium a mgnesium alloy AA3005 black with cut outs to hold panels module of 300 mm and at distance of 2.4 mtrs. the carrier shall be suspended by means of GI suspension rod 4mm diameter and suspension clip at 1.3 mtr.distancePaint finish:Alluminium panels shall be chromatised for maximum bond between metal and paint,enamelled twice under hgih temperatuve one side with full primer and Luxacote finish,the other side (Inner side) with a primer coat and skin coat on a Continous paint line. Seismic Zone V compliance - Metal facade should be Tested for Seismic Zone V compliance as per IS 1893 part 1-2016”Mode of measurement : Measurements shall be wall to wall without deductions for lights, diffusers, columns etc. Approved make :Hunter Douglas, Anutone, NLF Accoustic & orbit.

-

-

-

... More
Ground Floor

149.9

-

-

... More
First Floor

331.76

-

-

... More
Second Floor

287.09

-

-

... More
Third Floor

272.05

-

-

... More
Fourth Floor

56.47

-

-

... More
Providing & fixing of Airflex Smash approved Wooden flooring system that should be compliance with the Area elastic with total thickness of 75 mm comprising of 20mm Top Solid Wood followed by 45mm solid wood runner and l0mm Power Rubber Pad. Product top finish to have square Edge & UV Prefinished with Back Side Coating (Polished used of Klumpps from Germany which is sweat and saliva resistance according to DII 53160-1/2) to have higher polish life. The wooden flooring should have Eco-friendly manufacturing process with 100% sustainable and manageable plantation resource with raw material. The product should have been produced through K ilned and dried technology to maintain suitable moisture content. The top wood should necessarily be sourced from 100% sustainable resource and should have with prefinished including sanding & polishing. Structure of system should be l0mm thick rubber pad, 45 mm thick p ine runner with the width of 70mm, followed by the 20mm top flooring. Top wood plank sizes should be 20mm Thick, 130 mm Wide and 1830mm length. Runners to be placed at a distance of 305mm C/C. EntireApproved make : Ebaco, Airflex, NLF & orbit.

-

-

-

... More
Ground Floor

75.24

-

-

... More
First Floor

42.09

-

-

... More
Providing and fixing heavy duty Nylon floor carpet tiles with PVC backing make Candus, Hego Wiilton, Shaw, Milliken having following Technical Specifications- Fiber -100% Nylon Construction -Candus Nylon Loop pile , 1/10 Gauge with 6 mm pile height, total Height of 8mm, Pile Weight 680 GSM,Total Weight 1780 GSM with Action Back , Roll Width - 1.83 Mtr & Roll Length -25 Mtr, design as per candus manufacturer Carpet to be certified with FIRE-RETARDANT The floor which recieves the carpet to be thourougly cleaned as per manufacturer's specifications. The rate shall include supply, cutting, trimming, fixing of carpet. Texture and Color of the carpet shall be as per approval from the Engineer incharge.

-

-

-

... More
Second Floor

201.24

-

-

... More
Providing and fixing of Hunter Douglas manual roller blinds with Blackout or Sunscreen fsbric 5% or 10%. Control clutch drive unit engineered heavy duty chain drive pulley operating system consisting of gear clutch housing and locking plug containing 6 ribs and flexible to be inserted in 37mm or 50mm Roller tube. It is self lubricating exclusive clutch with safety pins for secure bracket installation and unlocking pin for quick manual removal. Universal clutch is most convenient for large windows down to the smallest windows. It shall be driven by a ball chain pulley with plastic ball chain and can be universally positioned either Right hand or Left hand side of the shade. Clutch gear ratio 1.75:1for reduced operating force on larger blinds. Tube bearing plug Idler: Exclusive self lubricating spring loaded plastic bearing end plug with positive locking wheel allows for adjustment and provides for a secure installation and removal of shade. Tube bearing plug contains 6 ribs and flexible to be inserted in 37mm or 50mm roller tube. Mounting Hardware Brackets: Universal brackets including end plug bracket with lock down retainer device. Brackets finish of powder coated Aluminium installation brackets made of stamped and hardened steel with 46mm projection for wall, ceiling and side fitting with screws and end cap covers. Valance Systems: Flat extruded valance alloy 6060 and temper T66 EN755 size of 5.6mm * 84.5mm and wall thickness 1.6mm with standard powder coat white finish. Valance systems protect and hide the front of the fabric on the tube, creating a more sleek look. Roller Tube: Circular-shaped aluminium tube extruded from alloy 6060 and temper T66 – EN755 of 37mm inside diameter and outside diameter 40.2mm extruded tube to have a 1.6mm wall thickness with standard anodized natural finish. Heavily reinforced with minimum six internal ribs providing additional deflection strength and allows for secure placements of clutch and end plug. Bottom Rail: Flat-shaped extruded aluminium from alloy 6060 and temper T66 – EN755 of dimension 13mm * 30mm and wall thickness of 1.5mm and weight more than 350g/m providing additional stability to avoid swaging and damage of shade fabric. Rail standard finish of powder coat white colour and provided end cover. Ball Chain: Shall be 2mm diameter cord with 4.5mm diameter acetal balls moulded coaxially to it on 11.8mm pitch to form an endless ball chain. It is used for raising or lowering action of the shades. Plastic parts: All plastic components are UV-stable compounds available white colour . Screen Fabric having Following Specification Composition: 24%PES+76%PVC Openness factor: Approx 5% Thickness: 0.56±5% mm Weight per ㎡ :445 ±5% g/m2Weave: Basket Weave 2 x 1 Fire resistance: NFPA 701 Color fastness: AATCC16 Grade 4-5 Health/Safety certificate: Oekotex /GreenGuard Blackout fabric having following specifications: Composition- 100% fiberglass with PVC coated or equivalent. washable Openness factor- opaque Weight (gram/ sqm)- min 407 g/sqm Thickness- min 0.51 mm Fire Classification- NFPA-701 or equivalent Fastness to light- 6-7/8 or higher Indoor Air Quality- GreenGuard / Eco-Codice Certified.Approved make :Hunter Douglas, Anutone, NLF, AMI & orbit.

-

-

-

... More
Ground Floor

40.32

-

-

... More
First Floor

47.52

-

-

... More
Second Floor

47.52

-

-

... More
Third Floor

47.52

-

-

... More
Fourth Floor

47.52

-

-

... More
Fifth Floor

17.64

-

-

... More
Luxalon® Lay-in Alu Plain Tile Ceiling System: Providing & fixing of Luxalon® Lay-in Tile Plain False Ceiling on 24mm ‘T’ Framework of module 600mm x 600mm. Panels shall be manufactured by Hunter Douglas of size 575mm x 575mm made out of 0.4mm thick Galvanised Steel. When the tiles are perforated it shall be 2.5mm dia 5.5mmc/c. Tiles to be stove enamelled on a continuous application for pre-treatment. The coils to go through 4 stages of pre-treatment, three times oven baked through conversion coating, priming and finish coat ensuring superior adhesion, high corrosion resistance and good colour stability. The coils to be painted on both sides after degreasing. Inside surface to have a primer of 5 microns and a coat of natural colour of 5 microns, exposed surface to have a primer of 5 microns, binder of 5 microns and topcoat of approved colour of 15 microns. The Tile will be manufactured on advanced equipment, which includes several levelling. The tile end shall be raised upward by 38mm and bend outward to lay the tile in framework. Grid system for fixing ceiling tiles shall comprise of Tees. The 24mm main tee runners shall be suspended at an interval of 1200mm centre to centre. The 24mm cross tee runner shall be suspended at 600mm centre to centre and further supported with 24mm cross tee at 600mm centre to centre with interlocking arrangements to form grid of 600mm x 600mm. The main tee shall be supported by means of 4mm G.I. rod from slab/roof. The suspension shall be provided at 1200 to 1500mm centre to centre. Mode of Measurements: Measurements shall be wall to wall without any deductions for lights, diffusers, columns etc. Approved Make :Hunter Douglas, Anutone, NLF, & Elegence.

-

-

-

... More
Ground Floor

74.73

-

-

... More
First Floor

67.21

-

-

... More
Second Floor

37.47

-

-

... More
Third Floor

52.15

-

-

... More
Fourth Floor

24.94

-

-

... More
Fifth Floor

9

-

-

... More
Designing, Providing, erecting and fixing structural glazing semi-unitized using specially designed aluminum grade 63400 WP IS: 733 and ID: 1285 electro colour anodized 25 micron or pure polyester powder coated 65 microns in approved shade and colour through adequately designed MS galvanized / aluminum anchor brackets. This includes structural grade and weathering grade silicon sealant ''Dow Corning'' or ''GE Silicon'' or equivalent as per the design requirement. This includes structural designing, shop drawing complete. The structure glazing shall be double glazed 23mm thick (6mm thick one way reflective on outer side, 12 mm air gap and 5 mm thick clear toughened glass on inner side). No members to visible from outside complete as per drawing and direction of engineer in charge. Including required aluminum sub-frame Silicon filling all height i/c double height for straight.

-

-

-

... More
Ground Floor

17.64

-

-

... More
First Floor

17.64

-

-

... More
Second Floor

17.64

-

-

... More
Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge. Note:- (1) The elevational area of the scaffolding shall be measured for payment purpose. (2) The payment will be made once only for execution of all items for such works.

-

-

-

... More
Second Floor

413.4

-

-

... More
Medium Height Partition @ 1800/1200HTTILE BASED PARTITION SYSTEM:- Tile based Aluminum partition system of 1800/1200 mm ht. made of 60mm thk aluminum frames having two separate race ways for laying electrical & computer wiring. The wire management shall be through to the race way to be fitted at bottom of partition and other immediately below of work top with hook on type raceway cover for easy access of wires. Frames to be joined by aluminum connectors with M6 x 16 pan-head machin screw and washer with aluminum post cover. Post cover of snap on fashion to be connected on aluminum connectors. All visible aluminium to be in anodized finish. The top/ exposed sides of the frame and posts should be covered with horizontal/ Vertical trim and caps made of Aluminum in anodized finish in order to enhance its look.Upper tiles of partition to be in Soft Board or Marker tile of 9mm. thk., and prelaminated partical board lower tiles in laminate finish of 9mm. thk. on both the sides.

-

-

-

... More
Ground Floor

13.11

-

-

... More
First Floor

59.41

-

-

... More
Second Floor

47.42

-

-

... More
Third Floor

47.78

-

-

... More
Fourth Floor

18.17

-

-

... More
Fifth Floor

16.82

-

-

... More
Providing & Fixing Curvilinear W/S tecitus @ 1500/1500Lx600/600Dx750/1200 HT, Tile based Aluminum partition system of 1200mm ht. made of 60mm thk aluminum frames having two separate race ways for laying electrical & computer wiring. The wire management shall be through to the race way to be fitted at bottom of partition and other immediately below of work top with hook on type raceway cover for easy access of wires. Frames to be joined by aluminum connectors with M6 x 16 pan-head machin screw and washer with aluminum post cover. Post cover of snap on fashion to be connected on aluminum connectors. All visible aluminium to be in anodized finish. The top/exposed sides of the frame and posts should be covered with horizontal/ Vertical trim and caps made of Aluminum in anodized finish in order to enhance its look. Upper tiles of partition to be in Soft Board or Marker tile of 9mm. thk., and prelaminated partical board lower tiles in laminate finish of 9mm. thk. on both the sides TOP to be made of 25 mm thick Prelaminated particle board with PVC edge band, GABLE END to be made of 25 mm thick Prelaminated particle board with PVC edge band, KEYBOARD TRAY (WITHOUT MOUSE TRAY ) :- Metal Powder Coated - Black Color, CPU TROLLEY :- Metal Powder Coated - Black Color, along with 3 DRAWER PEDESTAL UNIT having 2B + 1F PEDESTAL @ 400LX450DX670HT. : 2 Drawers & 1 Filling Drawer pedestal with leveller finish in 18 MM thk. Prelaminated partical Board Board 2MM PVC Edge band to all Exposed Area & Metal Drawer with Centralized Lock with handle.as per design and drawing and instructions of Engineer in charge. Aproved Make : NLF, Herman Miller,Steel case.

156

-

-

... More
Providing & Fixing linear W/S magna- Tile based Aluminum partition system of 1200mm ht. made of 60mm thk aluminum frames having two separate race ways for laying electrical & computer wiring. The wire management shall be through to the race way to be fitted at bottom of partition and other immediately below of work top with hook on type raceway cover for easy access of wires. Frames to be joined by aluminum connectors with M6 x 16 pan-head machin screw and washer with aluminum post cover. Post cover of snap on fashion to be connected on aluminum connectors. All visible aluminium to be in anodized finish. The top/exposed sides of the frame and posts should be covered with horizontal/ Vertical trim and caps made of Aluminum in anodized finish in order to enhance its look. Upper tiles of partition to be in Soft Board or Marker tile of 9mm. thk., and prelaminated partical board lower tiles in laminate finish of 9mm. thk. on both the sides TOP to be made of 25 mm thick Prelaminated particle board with PVC edge band, GABLE END to be made of 25 mm thick Prelaminated particle board with PVC edge band, KEYBOARD TRAY (WITHOUT MOUSE TRAY ) :- Metal Powder Coated - Black Color, CPU TROLLEY :- Metal Powder Coated - Black Color, along with 3 DRAWER PEDESTAL UNIT having 2B + 1F PEDESTAL @ 400LX450DX670HT. : 2 Drawers & 1 Filling Drawer pedestal with leveller finish in 18 MM thk. Prelaminated partical Board Board 2MM PVC Edge band to all Exposed Area & Metal Drawer with Centralized Lock with handle.as per design and drawing and instructions of Engineer in charge. Aproved Make : NLF, Herman Miller,Steel case.

14

-

-

... More
Main Table : 2400x900x750 mm. Table Top is made up of particle board with 1mm BSL. Total thickness of the Table top is 54mm with 36mm top & 18mm baton on visible sides. Table top is post laminated & Profile of the top is rectangular. Gable ends are 200mm wide made up of 18mm. modesty panel of 18mm particle board is post laminated 1mm on both sides. extension Joining Top : 800x900x750mm. Table Top is made up of particle board with 1mm BSL. Total thickness of the Table top is 54mm with 36mm top & 18mm baton on visible sides. Table top is post laminated & Profile of the top is rectangular. Gable ends are 200mm wide made up of 18mm. modesty panel of 18mm particle board is post laminated 1mm on both sides. Joining top is made up of 36mm particle board with 1mm BSL and is post-Laminated. Side Unit : 1200x500x750mm. Side table top is made up of 36mm particle board with 1mm BSL and is post-Laminated. Modesty is made up of 18mm particle board and understructure is made up of 25mm particle bord.PEDESTAL: 470X400X525MM. Mobile Pedestal with 2 D storage having telescopic slider channel. Facia with matching table top laminate. Castors are lockable and made up of Nylon. Central locking for all drawers & S S Handles for opening. Table top, side Storage in Post-Lam finish. Table has a dual tone shade in top & understructure and also similar in back units. All fittings are from Hettich. Hinge material is steel, nickel plated. as per design and drawing and instructions of Engineer in charge. Storage is completely handle less and is openable from the top Wire management is done concealed through legs for carrying wires within it. Access flap is provided on main table for provision of switches & sockets. Access flap is made up of aluminium extrusion & powder coated upto 50-60 microns. All Exposed edges have 2mm PVC edge banding from Rehau. Aproved Make : NLF, Herman Miller,Steel case.

23

-

-

... More
Main Table size 3200 X 900 X 750mm. Table Top is made up of 25mm thick prelam particle board. Modesty is 18mm Thick prelam particle board at offset position. Gable ends are made up of 25mm thick PPB. Side Unit : 900 X 450 X 750mm. Top of storage is made of 18mm thick PRELAM board.Doors, Shelf/ shelves side panel & front panel made of 18mm PRELAM board.Back panel made of 9 mm PRELAM board. Provision for adjustability of the panels inside the storage with pin support. 3 DRAWER PEDESTAL UNIT having 2B + 1F PEDESTAL @ 400LX450DX670HT. : 2 Drawers & 1 Filling Drawer pedestal with leveller finish in 18 MM thk. Prelaminated partical Board Board 2MM PVC Edge band to all Exposed Area & Metal Drawer with Centralized Lock with handle.Table top, modesty panel, gable end, Prelam particle board Passes resistance to low hazard flammability cigarette burns. Resistance to Stain, Crack, Steam, surface abrasion and adheres to Moisture & water absorption limits.PPB Confirms to IS:12823 GRADE & Complies to free formaldehyde content (IS: 13745:1993). Wire management is done through Grommets. All Exposed edges have 2mm PVC edge banding from Rehau. These edge bands are manufactured with virgin polymers and positive pretensioned to achieve perfect joint. Edge bands are resistance to regular cleaning agents against brittleness. as per design and drawing and instructions of Engineer in charge. Aproved Make : NLF, Herman Miller,Steel case.

10

-

-

... More
Main Table size 1400 X 700 X 750mm. Table Top is made up of 25mm thick prelam particle board. Modesty is 18mm Thick prelam particle board at offset position. Gable ends are made up of 25mm thick PPB. Side Unit : 900 X 450 X 750mm. Top of storage is made of 18mm thick PRELAM board.Doors, Shelf/ shelves side panel & front panel made of 18mm PRELAM board.Back panel made of 9 mm PRELAM board. Provision for adjustability of the panels inside the storage with pin support. 3 DRAWER PEDESTAL UNIT having 2B + 1F PEDESTAL @ 400LX450DX670HT. : 2 Drawers & 1 Filling Drawer pedestal with leveller finish in 18 MM thk. Prelaminated partical Board Board 2MM PVC Edge band to all Exposed Area & Metal Drawer with Centralized Lock with handle.Table top, modesty panel, gable end, Prelam particle board Passes resistance to low hazard flammability cigarette burns. Resistance to Stain, Crack, Steam, surface abrasion and adheres to Moisture & water absorption limits.PPB Confirms to IS:12823 GRADE & Complies to free formaldehyde content (IS: 13745:1993). Wire management is done through Grommets. All Exposed edges have 2mm PVC edge banding from Rehau. These edge bands are manufactured with virgin polymers and positive pretensioned to achieve perfect joint. Edge bands are resistance to regular cleaning agents against brittleness. as per design and drawing and instructions of Engineer in charge. Aproved Make : NLF, Herman Miller,Steel case.

8

-

-

... More
Main Table size 1200 X 700 X 750mm. Table Top is made up of 25mm thick prelam particle board. Modesty is 18mm Thick prelam particle board at offset position. Gable ends are made up of 25mm thick PPB. 3 DRAWER PEDESTAL UNIT having 2B + 1F PEDESTAL @ 400LX450DX670HT. : 2 Drawers & 1 Filling Drawer pedestal with leveller finish in 18 MM thk. Prelaminated partical Board Board 2MM PVC Edge band to all Exposed Area & Metal Drawer with Centralized Lock with handle.Table top, modesty panel, gable end, Prelam particle board Passes resistance to low hazard flammability cigarette burns. Resistance to Stain, Crack, Steam, surface abrasion and adheres to Moisture & water absorption limits.PPB Confirms to IS:12823 GRADE & Complies to free formaldehyde content (IS: 13745:1993). Wire management is done through Grommets. All Exposed edges have 2mm PVC edge banding from Rehau. These edge bands are manufactured with virgin polymers and positive pretensioned to achieve perfect joint. Edge bands are resistance to regular cleaning agents against brittleness. as per design and drawing and instructions of Engineer in charge. Aproved Make : NLF, Herman Miller,Steel case.

29

-

-

... More
Modular Conference System MAX one seater size 675mmL x 525mmW x 740mmH.Two seater : 1350mmL x 525mmWx 740mmH. Corner 1 Seater : 525mm x525mm in curvature with Table Top made of 25mm thick PPB.Understructure is made of 25mm thick standard black matt colour post formed panels connected with 18mm thick std black prelaminated modesty panels. Wire management - conecaled wire management to take care both horizontally & vertically. For open configurations, wire channel shall be mounted on the inner side of modesty panel for horizontal wire carrying. Vertical wire management shall be through flexible wire manager. Prelam finish confirming to Interior grade E2 board. Prelam particle board Passes resistance to low hazard flammability cigarette burns. Resistance to Stain, Crack, Steam, surface abrasion and adheres to Moisture & water absorption limits. Wire management is done through Grommets. All Exposed edges have 2mm PVC edge banding from Rehau. These edge bands are manufactured with virgin polymers and positive pretensioned to achieve perfect joint. Edge bands are resistance to regular cleaning agents against brittleness. as per design and drawing and instructions of Engineer in charge.Aproved Make : NLF, Herman Miller,Steel case. CONFERENCE TABLE - 2700L x1200D x750HT

1

-

-

... More
Main Table size 3125 X 700 X 750mm. Table Top is made up of 25mm thick prelam particle board. Modesty is 18mm Thick prelam particle board at offset position. Gable ends are made up of 25mm thick PPB. .Table top, modesty panel, gable end, Prelam particle board Passes resistance to low hazard flammability cigarette burns. Resistance to Stain, Crack, Steam, surface abrasion and adheres to Moisture & water absorption limits.PPB Confirms to IS:12823 GRADE & Complies to free formaldehyde content (IS: 13745:1993). Wire management is done through Grommets. All Exposed edges have 2mm PVC edge banding from Rehau. These edge bands are manufactured with virgin polymers and positive pretensioned to achieve perfect joint. Edge bands are resistance to regular cleaning agents against brittleness. as per design and drawing and instructions of Engineer in charge. Aproved Make : NLF, Herman Miller,Steel case.

3

-

-

... More
6 Seater Cafeteria Table Understructure :- The understructure has 4 vertical pipe with angular legs connected horizontally. The prongs are made of 2mm thick SS 202. The prongs are connected to a vertical pipe. The height of the pipe is 575mm. The vertical pipe is connected to the table support bracket. The dimension of the top support bracket is 215mm x 45mm and is made of 1.6mm thick SS 202. The complete understructure is supported by levelers of 19mm made of Nylon M8 threads. The dia of the Nylon leveler is 75mm. Table Top :- The table top can be either 25mm thick membrane as per the requirement come in multi colour.Aproved Make : NLF, Herman Miller,Steel case.

6

-

-

... More
STORAGE @ 1500x6001200HT. : Openable Shutter finish in 18 MM thk. Prelaminated Particle Panel with 2MM PVC Edge band to all .Body is made from 18mm PLB with all the edges sealed with 0.8 mm thick PVC Edgeband. The Back panel is 9mm White PPB. The entire construction is ready to assemble unit and is assembled with suitable KD fittings. The shelves and separator panels ( if available ) is made from 18 mm white PPB and edges are sealed with 0.8 mm edge band. The bottom shelf is fixed and other shelves have one step adjustment for optimizing the space.All the storages are fitted with a 6 mm leveler at bottom for leveling. (Hardware, BY Hettich Make) as per design and drawing and instructions of Engineer in charge. Aproved Make : NLF, Herman Miller,Steel case.

132

-

-

... More
Providing and fixing of wooden center table of size (1200 mm length x 600mm width x 400/450 mm high) or equivqlent size or as per design, table top made with 18/19 mm BWR plywood and finish with 4mm thick decorative veneer or table top frame made with first class quality seasoned teak / sheesham wood frame of size 40 mm x 80 mm finished and 8 mm thick bevelled edge table top glass and legs of the table made with first class best quality seasoned teak / sheesham wood as per detail drawing. All wooden & veneer surfaces shall be dully melamine polished. All work shall be carried out as per detail drawing and instruction of Architect/Engineer-in-charge.Aproved Make : NLF, Herman Miller,Steel case.

4

-

-

... More
HIGHBACK CHAIRS - ( CHAMBER - MAIN CHAIRS)Supplying and placing the High back chairs with Backrest:- Back Type - Medium Back, Seat to Backrest Height - 555mm, Backrest Height - 705mm, Backrest Width - 560mm(Max), Backrest Construction - Ply+Foam, Finish - Leather/Fabric, Seat to Back rest height complies with BIFMA Section no 7.5.1 Table 21, Backrest width complies with BIFMA Section no 7.5.2 Table 21, Backrest is made out of 12 mm multilayer BWP ply., PU foam of 37 mm thickness and density of 32Kg/m Seat Rest:- Width Excluding Arms - 490mm, Depth including of Waterfall edge - 490mm, Min Seat Height - 435mm, Max Seat Height - 550mm, Finish - Leatherite/Fabric, *500 mm is width when 3D arm is used, Seat depth complies with BIFMA Section 7.2 Table 21, Seat width complies with BIFMA Section 7.3 Table 21, Seat Height Adjustment complies with EN1335 -1: 2000 Type A Seat Foam:- Made out of High resilience foam with the following properties Density 58-61 Kg/m, (IFD) Indentation: Force Deflection 25% 21.5 Kgf/cm, Tensile strength 2.0 Kgf/cm, Tear strength 1.0 Kgf/cm, Resilience 60% Mechanism: Synchro 4 Position BIFMA Compliant Mechanism Back Tilt: 89 - 109 degrees, Seat Tilt: 0 - 6 degrees, Tension Adjustment: Back tension can be regulated by operating from the side mounted knob while seated on the chair, Locking Positions: 4 positions, can be locked & unlocked by lever, Tested for 3, 00,000 Cycles as per ANSI BIFMA X5.1 -2002, Movements of Seat Pan & Back Support complies with BIFMA Section no 7.6 Table 21 OR SINGLE POINT SYNCHRO MECHANISM : Conventional mechanism with one lever control for lock and seat height adjustment. Mechanism made out of MS Plate thickness is 3mm and seat is tilting angle is 3°~10°. and back tilting angle is 87°~106°. Also it has the back tension adjustment knob. Mechanism tested for 3, 00,000 Cycles as per ANSI / BIFMA X5.1. Gas Lift: Meets DIN 4550 Class 3, Meets ANSI BIFMA performance standards, Tested for 1, 00,000 Cycles Caster: PU Caster Dia 60 mm, Complies to ANSI / BIFMA X 5.1 – 2002, Tested for 1, 00,000 Cycles : The twin wheel castors are injection mouled in nylon and diameter of Castor 60 mm. The castors are tested for 1,00,000 Cycles as per ANSI / BIFMA X 5.1.BASE : The base made up of injection moulded in black glass filled nylon and fitted with 5Nos twin wheel castors. The base is 658mm pitch circle dimeter. The base tested for static load of 1134Kg as per ANSI / BIFMA X 5.1. ALUMINIUM BASE : The base made up of pressure die casted in aluminium fitted with 5Nos twin wheel castors. The base is 650mm pitch circle dimeter. The base tested for static load of 1134Kg as per ANSI / BIFMA X 5.1. Armrests:- Armrest Option - 2D/3D Arms, Armrest Height from the seat - 210-290mm, Armrest Width excluding Armpads - 85mm, Arm pad length - 250mm, Arm pad finish - PU, The above Arm rest comply with ANSI BIFMA X 5.1 -2002 Clause 13.4 Upholstery:- Leather only available in two colors (Classic Black & Camel).Seat Fabric with the following properties :Content: 100%Polyester, Weight: 340 GSM, Abrasion: over 30000, Flammability: Adheres to California Technical Bulletin117 Section E , part 1(CS191-53), Color Fastness to Light: Adheres to Grade 5 [ISO 105-B02:1997] , [GB/T8427-1998], Rubbing; Adheres to Dry: Grade 4- 5 [ATTCC8:2001] ,[GB/T3920-1997] Adheres to Wet: Grade 4-5 [ATTCC8:2001] ,[GB/T3920-1997] Aproved Make : NLF, Herman Miller,Steel case.

21

-

-

... More
High Back Mesh Chair with Synchro 1 Mechanism with adjustable lumbar support. One dimensional height adjustable PU arm rest. Ply moulded seat upholstered with fabric. Seat is designed with waterfall edges for smooth blood circulation in legs. chair assembly is mounted on Class-IV gas lift having Nylon base and 55mm Nylon castors.Approved Make : NLF, Herman Miller & Steel Case

10

-

-

... More
MEDIUM BACK CHAIRS- (CHAMBER - VISITOR CHAIR)Supplying and placing the Directors Visirors/Medium back chairs with Backrest:- Back Type - Medium Back, Seat to Backrest Height - 555mm, Backrest Height - 705mm, Backrest Width - 560mm(Max), Backrest Construction - Ply+Foam, Finish - Leather/Fabric, Seat to Back rest height complies with BIFMA Section no 7.5.1 Table 21, Backrest width complies with BIFMA Section no 7.5.2 Table 21, Backrest is made out of 12 mm multilayer BWP ply., PU foam of 37 mm thickness and density of 32Kg/m Seat Rest:- Width Excluding Arms - 490mm, Depth including of Waterfall edge - 490mm, Min Seat Height - 435mm, Max Seat Height - 550mm, Finish - Leather/Fabric, *500 mm is width when 3D arm is used, Seat depth complies with BIFMA Section 7.2 Table 21, Seat width complies with BIFMA Section 7.3 Table 21, Seat Height Adjustment complies with EN1335 -1: 2000 Type A Seat Foam:- Made out of High resilience foam with the following properties Density 58-61 Kg/m, (IFD) Indentation: Force Deflection 25% 21.5 Kgf/cm, Tensile strength 2.0 Kgf/cm, Tear strength 1.0 Kgf/cm, Resilience 60% Mechanism: Synchro 4 Position BIFMA Compliant Mechanism Back Tilt: 89 - 109 degrees, Seat Tilt: 0 - 6 degrees, Tension Adjustment: Back tension can be regulated by operating from the side mounted knob while seated on the chair, Locking Positions: 4 positions, can be locked & unlocked by lever, Tested for 3, 00,000 Cycles as per ANSI BIFMA X5.1 -2002, Movements of Seat Pan & Back Support complies with BIFMA Section no 7.6 Table 21 OR SINGLE POINT SYNCHRO MECHANISM : Conventional mechanism with one lever control for lock and seat height adjustment. Mechanism made out of MS Plate thickness is 3mm and seat is tilting angle is 3°~10°. and back tilting angle is 87°~106°. Also it has the back tension adjustment knob. Mechanism tested for 3, 00,000 Cycles as per ANSI / BIFMA X5.1. Gas Lift: Meets DIN 4550 Class 3, Meets ANSI BIFMA performance standards, Tested for 1, 00,000 Cycles Caster: PU Caster Dia 60 mm, Complies to ANSI / BIFMA X 5.1 – 2002, Tested for 1, 00,000 Cycles OR NYLON CASTORS : The twin wheel castors are injection mouled in nylon and diameter of Castor 60 mm. The castors are tested for 1,00,000 Cycles as per ANSI / BIFMA X 5.1.BASE : NYLON BASE : The base made up of injection moulded in black glass filled nylon and fitted with 5Nos twin wheel castors. The base is 658mm pitch circle dimeter. The base tested for static load of 1134Kg as per ANSI / BIFMA X 5.1. ALUMINIUM BASE : The base made up of pressure die casted in aluminium fitted with 5Nos twin wheel castors. The base is 650mm pitch circle dimeter. The base tested for static load of 1134Kg as per ANSI / BIFMA X 5.1. Armrests:- Armrest Option - 2D/3D Arms, Armrest Height from the seat - 210-290mm, Armrest Width excluding Armpads - 85mm, Arm pad length - 250mm, Arm pad finish - PU, The above Arm rest comply with ANSI BIFMA X 5.1 -2002 Clause 13.4 Upholstery:- Leather only available in two colors (Classic Black & Camel).Seat Fabric with the following properties : Content: 100%Polyester, Weight: 340 GSM, Abrasion: over 30000, Flammability: Adheres to California Technical Bulletin117 Section E , part 1(CS191-53), Color Fastness to Light: Adheres to Grade 5 [ISO 105-B02:1997] , [GB/T8427-1998], Rubbing; Adheres to Dry: Grade 4- 5 [ATTCC8:2001] ,[GB/T3920-1997] Adheres to Wet: Grade 4-5 [ATTCC8:2001] ,[GB/T3920-1997]Aproved Make : NLF, Herman Miller,Steel case.

52

-

-

... More
Medium Back Mesh Chair with Synchro 1 Mechanism with adjustable lumbar support. One dimensional height adjustable PU arm rest. Ply moulded seat upholstered with fabric. Seat is designed with waterfall edges for smooth blood circulation in legs. chair assembly is mounted on Class-IV gas lift having Nylon base and 55mm Nylon castors.Approved Make : NLF, Herman Miller & Steel Case

25

-

-

... More
HIGHBACK CHAIRS - (CABIN, CONFERENCE- MAIN CHAIRS) Providing and fixing Back Rest:- Back type - High Back, Seat to Backrest Height - 650mm, Backrest Height - 790mm, Backrest Width - 500mm, Backrest Construction - Ply+Foam, Finish - Fabric/Leatherite, Seat to Back rest height complies with BIFMA Section no 7.5.1 Table 21, Backrest width complies with BIFMA Section no 7.5.2 Table 21, Backrest is made out of 12 mm multilayer BWP ply. PU foam of 50 mm thickness Seat Rest:- Width Excluding Arms - 460-500mm, Depth including of Waterfall edge - 470mm, Min Seat Height - 440mm, Max Seat Height - 540mm, Finish - Fabric/Leatherite, *500 mm is width when 3D arm is used, Seat depth complies with BIFMA Section 7.2 Table 21, Seat width complies with BIFMA Section 7.3 Table 21, Seat Height Adjustment complies with EN1335 -1: 2000 Type A Seat Foam:- Made out of High resilience foam with the following properties: Density 58-61 Kg/m, (IFD) Indentation: Force Deflection 25% 21.5 Kgf/cm, Tensile strength 2.0 Kgf/cm, Tear strength 1.0 Kgf/cm, Resilience 60% Mechanism: Synchro 4 Position BIFMA Compliant Mechanism: Back Tilt: 89 - 109 degrees, Seat Tilt: 0 - 6 degrees, Tension Adjustment: Back tension can be regulated by operating from the side mounted knob while seated on the chair, Locking Positions: 4 positions, can be locked & unlocked by lever, Tested for 3, 00,000 Cycles as per ANSI BIFMA X5.1 -2002, Movements of Seat Pan & Back Support complies with BIFMA Section no 7.6 Table 21 OR Synchro 1 Position BIFMA Compliant Mechanism: Back Tilt: 87 -106 degrees, Seat Angle: 3-10 degrees, With back tension adjustment knob, Locking Positions: 1 position, can be locked & unlocked by lever, Tested for 3, 00,000 Cycles as per ANSI BIFMA X5.1 -2002, Movements of Seat Pan & Back Support complies with BIFMA Section no 7.6 Table 21 Gas Lift: Meets DIN 4550 Class 3, Meets ANSI BIFMA performance standards, Tested for 1, 00,000 Cycles Caster:- Options for Nylon 50 mm / PU 60 mm, Complies to ANSI / BIFMA X 5.1 – 2002, Tested for 1,00,000 Cycles - Aluminium, Static Load as per ANSI / BIFMA X 5.1 2.2 – 2002 Clause 7 - 1134Kg, Pitch Circle Diameter - 640mm, Finish - Aluminium Polished Armrests:- Armrest Option - Fixed, Armrest Height from the seat - 175mm, Armrest Width excluding Armpads - 55mm, Arm pad length - 320mm, Arm pad finish - PP OR Armrest Option - Height Adjustable, Armrest Height from the seat - 180-260mm, Armrest Width excluding Armpads - 80mm, Arm pad length - 270mm, Arm pad finish - PP OR Armrest Option - 2D, Armrest Height from the seat - 180-260mm, Armrest Width excluding Armpads - 90mm, Arm pad length - 250mm, Arm pad finish - PU OR Armrest Option - 3D, Armrest Height from the seat - 180-260mm, Armrest Width excluding Armpads -

82

-

-

... More
Visitor Chair, Wooden Frame, Cushion Arm, Chrome Plated pipe standAproved Make : NLF, Herman Miller,Steel case.

80

-

-

... More
MEDIUM BACK CHAIRS - (STAFF CHAIR) Providing and fixing Executive Medium Back chairs with Back Rest:- Back type - Medium Back, Seat to Backrest Height - 500mm, Backrest Height - 630mm, Backrest Width - 490mm, Backrest Construction - Ply+Foam, Finish - Fabric/Leatherite, Seat to Back rest height complies with BIFMA Section no 7.5.1 Table 21, Backrest width complies with BIFMA Section no 7.5.2 Table 21, Backrest is made out of 12 mm multilayer BWP ply. PU foam of 50 mm thickness Seat Rest:- Width Excluding Arms - 460-500mm, Depth including of Waterfall edge - 470mm, Min Seat Height - 440mm, Max Seat Height - 540mm, Finish - Fabric/Leatherite, *500 mm is width when 3D arm is used, Seat depth complies with BIFMA Section 7.2 Table 21, Seat width complies with BIFMA Section 7.3 Table 21, Seat Height Adjustment complies with EN1335 -1: 2000 Type A Seat Foam:- Made out of High resilience foam with the following properties: Density 58-61 Kg/m, (IFD) Indentation: Force Deflection 25% 21.5 Kgf/cm, Tensile strength 2.0 Kgf/cm, Tear strength 1.0 Kgf/cm, Resilience 60% Mechanism: Synchro 4 Position BIFMA Compliant Mechanism: Back Tilt: 89 - 109 degrees, Seat Tilt: 0 - 6 degrees, Tension Adjustment: Back tension can be regulated by operating from the side mounted knob while seated on the chair, Locking Positions: 4 positions, can be locked & unlocked by lever, Tested for 3, 00,000 Cycles as per ANSI BIFMA X5.1 -2002, Movements of Seat Pan & Back Support complies with BIFMA Section no 7.6 Table 21 OR Synchro 1 Position BIFMA Compliant Mechanism: Back Tilt: 87 -106 degrees, Seat Angle: 3-10 degrees, With back tension adjustment knob, Locking Positions: 1 position, can be locked & unlocked by lever, Tested for 3, 00,000 Cycles as per ANSI BIFMA X5.1 -2002, Movements of Seat Pan & Back Support complies with BIFMA Section no 7.6 Table 21 Gas Lift: Meets DIN 4550 Class 3, Meets ANSI BIFMA performance standards, Tested for 1, 00,000 Cycles Caster:- Options for Nylon 50 mm / PU 60 mm, Complies to ANSI / BIFMA X 5.1 – 2002, Tested for 1,00,000 Cycles Base:- Type of Base - Nylon, Static Load as per ANSI / BIFMA X 5.1 2.2 – 2002 Clause 7 - 1134Kg, Pitch Circle Diameter - 640mm, Finish - Black Matt OR Armrests:- Armrest Option - Fixed, Armrest Height from the seat - 175mm, Armrest Width excluding Armpads - 55mm, Arm pad length - 320mm, Arm pad finish - PP OR Armrest Option - Height Adjustable, Armrest Height from the seat - 180-260mm, Armrest Width excluding Armpads - 80mm, Arm pad length - 270mm, Arm pad finish - PP OR Armrest Option - 2D, Armrest Height from the seat - 180-260mm, Armrest Width excluding Armpads - 90mm, Arm pad length - 250mm, Arm pad finish - PU OR Armrest Option - 3D, Armrest Height from the seat - 180-260mm, Armrest Width excluding Armpads - 90mm, Arm pad length - 250mm, Arm pad finish - PU, The above Arm rest comply with ANSI BIFMA X 5.1 -2002 Clause 13.4 Upholstery:- Available in Fabric & Leatherette options, Wipro Delta Range Fabric: (Delta Orange / Delta Wine Red / Delta Black): Content: 100% Polyester, Weight:Abrasion: 80,000 Flammability: BS EN 1021-1 1994 (Cigarette) BS 7176:1995 (Low Hazard), Color Fastness to Light: 5+ [BS 1006 (1990)], Rubbing; Dry: Class 5 Wet: Class 4.5 . Aproved Make : NLF, Herman Miller,Steel case.

326

-

-

... More
Providing and fixing Canteen Chairs with Back Rest:- Back type - Back Rest, Seat to Backrest Height - 400mm, Backrest Height - 430mm, Backrest Width - 440mm (Max), Material - PP, Color / Finish - Blue, Red, Yellow, Orange -TexturedSeat:- Seat Height - 454mm, Width of Seat - 420mm (Max), Depth of Seat - 435mm, Material - PP, Color / Finish - Blue, Red, Yellow, Orange -Textured Understructure:- Material - PP full body Multi colour Aproved Make : NLF, Herman Miller,Steel case.

30

-

-

... More
AUDITORIUM CHAIRS Providing and fixing BIFMA Certified Wipro Make Auditorium Chair ( Box office - Ballet Model), BOX-OFFICE BALLET is a Push Back chair(fluimatic slider mechanism). STRUCTURE:- Frame :Back Rest frame of ERW Tube / IS :3074-2005 GRADE 1-16 dia Round Pipe 1.2mm Thickness & Extra Reinforcement 16 dia round pipe 1.2 mm. Cushion Frame (Seat) ERW Tube / IS :3074-2005 GRADE 1- 22 dia Round Pipe 1.63mm Thickness WING COMPONENTS:-a) Wing frame Rectangular Frame. Side wing frame with plywood. with upholstery. b) Leg : sq TUBE IS:4923-1997- 25X25 mm , 1.63 Thickness SPRINGS:- Seat : For Auto Tip-up – Torsion Spring / Spring Steel IS : 4454 1981 GRADE 3 (part i) Tested for 5,00,000 cycles. For Push Back mechanism – Coil Spring / Spring Steel IS : 4454 1981 GRADE 2 Tested for 1,00,000 Cycles.FOAM:- Automotive Grade High Resilence-HR Polyurathene foam, Density: 50 + 5 Kg/M3 / JIS K 6401, Constant Compression Set: (Max. 13%) JIS K 6401. BACK AND CUSHION HOUSING:- PPCP IS: 10915 1994./ Injection Molded/Thermoform Plastic.FINISH:- Seat Cushions Dimensions are in-line with Anthropometric Datas & Ergonomically profiled Contours. BACKHEIGHT:- Height of top of the back from ground level 1030 +/-15mm. EFFECTIVE SEAT DEPTH:- Seat Cushions Dimensions are in-line with Anthropometric Datas & Ergonomically profiled Contours. Seat depth is 448mm.Height from ground level is 445+/-10mm. TYPE OF BACKREST:- Option 1 Slider (Fluimatic mechanism) – 60mm travels.with metal ball and roller cage which results in PUSH BACK OF 140 + 10mm. Should have flexibility to restrict movement of the pushback and slider as per avialability of aisle space. Option 2 Fixed Back chair ARMREST:- Option 1:- Polyurathane waterfall edge design armrest, 2: Polypropelene Cupholder Armrest ARMREST CENTER TO CENTER DISTANCE:- 21/22/23/24 inch width GROUTING:- 4 nos of 75mm (for hard floor) NOTE: for Wooden flooring the wooden wood thickness of 40mm & for Fixing the chair scotch bolt of Size M8X50MM is require FABRIC:- heavy duty 100 % poyester dyed yarn with 3mm + .5mm foam backing resultatent. AISLE SIDE LAMP:- Provision for lights on sides for seats along the aisles.Polypropelene Housing with 12mm watt lamp ROW NUMBERING:- Row numbering for seats along the aisles.2mm alluminium cutouts with row numering A,B,C….. SEAT NUMBERING:- Seat numbering on back and tip-up portion 2mm aluminium oval strips with seat numbering 1,2,3….. Aproved Make : NLF, Herman Miller,Steel case

196

-

-

... More
Providing and fixing of Multi purpose chairs with Back Rest:- Seat to Backrest Height - 380mm, Backrest Height - 255mm, Backrest Width - 480mm, Backrest Construction - Ply + Foam, Finish - Fabric, Seat to Back rest height complies with BIFMA Section no 7.5.1 Table 21, Backrest width complies with BIFMA Section no 7.5.2 Table 21, Backrest is made out of 12 mm multilayer BWP ply. PU foam of 40 mm thickness Seat:- Width B/w Arms - 455mm, Depth including of Waterfall edge - 460mm, Seat Height - 470mm, Finish - Fabric, Seat depth complies with BIFMA Section 7.2 Table 21, Seat width complies with BIFMA Section 7.3 Table 21Seat Foam:- Made out of High resilience foam with the following properties - Density 58-61 Kg/m, (IFD) Indentation: Force Deflection 25% 21.5 Kgf/cm, Tensile strength 2.0 Kgf/cm, Tear strength 1.0 Kgf/cm, Resilience 60% Armrests:- Armrest Option - Arms -With Tablet, Armrest Height from the seat - 229mm, Armrest Width excluding Armpads - 48mm, Arm pad length - 240mm, Arm pad finish - PU, The above Arm rests comply with ANSI BIFMA X 5.1 -2002 Clause 13.4 Understructure:- Material - ERW PIPE (IS 1161-1998), Color - Light metallic grey, Finish - Power coat Wipro Plano Range Fabric:- Composition: 100% Polyester, Weight: 415 Grams per linear meter, Thickness: 295/GSM, Width: 55”, Abrasion Resistance: In excess of 50,000 cycles (800g/12kpa) Martindale, Color Fastness to Light: 5+ {BS 1006 (1990)}, Color Fastness to Rubbing: Dry: class 5, Wet: class 4.5, Color Matching: Batch to batch variation in shade may occur within commercial tolerances, Maintenance: Professional cleaning recommended, Flammability: BS EN 1021 - 1: 1994 (Cigarette), BS EN 1021 - 1: 1994 (Low Hazzard), Sweat Rubbing: 4, Tear Strength: Warp = 14 Kg, Weft = 13 Kg .Aproved Make : NLF, Herman Miller,Steel case.

100

-

-

... More
Providing and fixing BIFMA Certified sofa, Frame Constructio- Kiln seasoned mixed meranti solid tropical hard wood, Seats Webbing:- 3" diagonal pattern webbing, Foam:- 7" Multilayered foams Having 4" of High Resilience-HD Foam and 3" of HD virgin PU Foam. BACKREST Webbing:- 2" elastic webbing, Backrest Foam:- 18D PU foam, Upholstery:- semi PU with layer of polyester polywadding, Stitiching:- Nylon Bonded thread, Glue - Sp4 from Pidilite, Legs - Solid kiln seasoned and treated Solid wood with melamine matt finish THREE SEATER SOFA 3 SEATER:- 2065(L) X 850(W) X 760(H)MM Aproved Make : NLF, Herman Miller,Steel case.

27

-

-

... More
Modular Conference System MAX one seater size 675mmL x 525mmW x 740mmH.Two seater : 1350mmL x 525mmWx 740mmH. Corner 1 Seater : 525mm x525mm in curvature with Table Top made of 25mm thick PPB.Understructure is made of 25mm thick standard black matt colour post formed panels connected with 18mm thick std black prelaminated modesty panels. Wire management - conecaled wire management to take care both horizontally & vertically. For open configurations, wire channel shall be mounted on the inner side of modesty panel for horizontal wire carrying. Vertical wire management shall be through flexible wire manager. Prelam finish confirming to Interior grade E2 board. Prelam particle board Passes resistance to low hazard flammability cigarette burns. Resistance to Stain, Crack, Steam, surface abrasion and adheres to Moisture & water absorption limits. Wire management is done through Grommets. All Exposed edges have 2mm PVC edge banding from Rehau. These edge bands are manufactured with virgin polymers and positive pretensioned to achieve perfect joint. Edge bands are resistance to regular cleaning agents against brittleness. as per design and drawing and instructions of Engineer in charge.Aproved Make : NLF, Herman Miller,Steel case. CONFERENCE TABLE - 6950L x2400D x750HT

2

-

-

... More
Modular Conference System MAX one seater size 675mmL x 525mmW x 740mmH.Two seater : 1350mmL x 525mmWx 740mmH. Corner 1 Seater : 525mm x525mm in curvature with Table Top made of 25mm thick PPB.Understructure is made of 25mm thick standard black matt colour post formed panels connected with 18mm thick std black prelaminated modesty panels. Wire management - conecaled wire management to take care both horizontally & vertically. For open configurations, wire channel shall be mounted on the inner side of modesty panel for horizontal wire carrying. Vertical wire management shall be through flexible wire manager. Prelam finish confirming to Interior grade E2 board. Prelam particle board Passes resistance to low hazard flammability cigarette burns. Resistance to Stain, Crack, Steam, surface abrasion and adheres to Moisture & water absorption limits. Wire management is done through Grommets. All Exposed edges have 2mm PVC edge banding from Rehau. These edge bands are manufactured with virgin polymers and positive pretensioned to achieve perfect joint. Edge bands are resistance to regular cleaning agents against brittleness. as per design and drawing and instructions of Engineer in charge.Aproved Make : NLF, Herman Miller,Steel case. CONFERENCE TABLE - 5650L x2400D x750HT

2

-

-

... More
Modular Conference System MAX one seater size 675mmL x 525mmW x 740mmH.Two seater : 1350mmL x 525mmWx 740mmH. Corner 1 Seater : 525mm x525mm in curvature with Table Top made of 25mm thick PPB.Understructure is made of 25mm thick standard black matt colour post formed panels connected with 18mm thick std black prelaminated modesty panels. Wire management - conecaled wire management to take care both horizontally & vertically. For open configurations, wire channel shall be mounted on the inner side of modesty panel for horizontal wire carrying. Vertical wire management shall be through flexible wire manager. Prelam finish confirming to Interior grade E2 board. Prelam particle board Passes resistance to low hazard flammability cigarette burns. Resistance to Stain, Crack, Steam, surface abrasion and adheres to Moisture & water absorption limits. Wire management is done through Grommets. All Exposed edges have 2mm PVC edge banding from Rehau. These edge bands are manufactured with virgin polymers and positive pretensioned to achieve perfect joint. Edge bands are resistance to regular cleaning agents against brittleness. as per design and drawing and instructions of Engineer in charge.Aproved Make : NLF, Herman Miller,Steel case. CONFERENCE TABLE - 3600L x1350D x750HT

1

-

-

... More
Modular Conference System MAX one seater size 675mmL x 525mmW x 740mmH.Two seater : 1350mmL x 525mmWx 740mmH. Corner 1 Seater : 525mm x525mm in curvature with Table Top made of 25mm thick PPB.Understructure is made of 25mm thick standard black matt colour post formed panels connected with 18mm thick std black prelaminated modesty panels. Wire management - conecaled wire management to take care both horizontally & vertically. For open configurations, wire channel shall be mounted on the inner side of modesty panel for horizontal wire carrying. Vertical wire management shall be through flexible wire manager. Prelam finish confirming to Interior grade E2 board. Prelam particle board Passes resistance to low hazard flammability cigarette burns. Resistance to Stain, Crack, Steam, surface abrasion and adheres to Moisture & water absorption limits. Wire management is done through Grommets. All Exposed edges have 2mm PVC edge banding from Rehau. These edge bands are manufactured with virgin polymers and positive pretensioned to achieve perfect joint. Edge bands are resistance to regular cleaning agents against brittleness. as per design and drawing and instructions of Engineer in charge.Aproved Make : NLF, Herman Miller,Steel case. CONFERENCE TABLE - 3600L x1350D x750HT

1

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering, formwork ,cover blocks, laying/pumping, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)

133.7

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)

-

-

-

... More
Ground Floor

67.48

-

-

... More
First Floor

2.79

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)

-

-

-

... More
Ground Floor

74.06

-

-

... More
First Floor

4.01

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)

67.27

-

-

... More
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete.

282.56

-

-

... More
Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete.

272.6

-

-

... More
Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc.complete

58.91

-

-

... More
Providing and fixing 15 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete.

4

-

-

... More
Providing and fixing screw down 15 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete

2

-

-

... More
Providing and fixing screw down for 20 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete.

2

-

-

... More
Providing and fixing screw down for 25 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete.

2

-

-

... More
Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffoldingand curing etc. complete.

400.14

-

-

... More
Providing internal cement plaster 20mm thick in Single coats in cement mortar 1:4without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc.complete.

302.42

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete M-15 of trap/ granite/quartzite/gneiss metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With fine aggregate (Crushed sand VSI Grade)

6.06

-

-

... More
Providing expansion joints in R.C.C. framed structure (exterior Columns) with plain premoulded filler 25 mm thick and 3 mm thick alluminium plate, hold fast, fixing T.W. battens on internal face, finishing etc. complete as directed.

14.28

-

-

... More
Providing and fixing bituminous pad 25mm thick for expansion joints in retaining wall, compound wall etc. complete.

12.75

-

-

... More
Providing and erecting chain link fencing 1.6 M. height with G.I. chain link of size 50 x 50 mm, 8 gauge thick and fixed 75 mm above ground level on vertical M.S. Angles of 40 x 40 x 6 mm size, includind excavating pits for foundation and embedded in C.C. block of 1:4:8 mix of size 450 x 450 x 670 mm. at 1.75 M. c/c with iron bar 16mm dia as hold fast including welding link with angle frame at 30 cm c/c with nuts and bolts and horizontal without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc.complete.

474.64

-

-

... More
Providing internal cement plaster 6 mm thick in a single coat in cement mortar 1:4 without neeru finish to concrete surface in all positions including scaffolding and curingetc. complete.

-

-

-

... More
Ground Floor

36.9

-

-

... More
First Floor

44.01

-

-

... More
Excavation for roadway in earth, soil of all sorts, sand, gravel or soft murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50m. and spreading for embankment orstacking as directed.

961.26

-

-

... More
Construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader / Paver on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- By Mix in Place Method and Grading - I

961.26

-

-

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with vibratory roller to the required density. By Mechanical Means -Grading I (Using Screening Type B (11.2 mm) Aggregate)

537.16

-

-

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with vibratory roller to the required density. By Mechanical Means - Grading II (Using Screening Type B (11.2 mm) Aggregate)

480.63

-

-

... More
Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate ( natural sand/ VSI grade finely washed crushed sand) conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, , cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor /by suitable means as approved by Engineer-in- charge , compacting with vibratory roller, finishing, curing and including preparation of sub-grade surface if required etc. complete. with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete.

640.84

-

-

... More
Providing and laying in-situ M30 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement , coarse and fine aggregate( natural sand/ VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver,compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6m X 0.6m centre to centre, admeasuring 80 mm at bottom and 40 mm at top with depth of 75mm and maintaining the same throughout curing period by any other method approved by Engineer-in-charge. with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete.

365.46

-

-

... More
Providing and laying 125 micron Low Density Polyethylene (LDPE) sheet confirming to IS 3395 : 1997 below concrete pavement including all materials and labour complete.

6296.98

-

-

... More
Cutting transverse contraction joints 3 to 4 mm wide and depth 60mm. .in concrete slab using concrete cutting machine with diamond studded saw within 48 hours of casting of bay / slab etc. complete including subsequent widening of the groove 8 to 10 mm. wide at top having depth of 15 mm. as directed by Engineer incharge.

2326

-

-

... More
Cutting transverse contraction joints 3 to 4 mm wide and depth 60mm. .in concrete slab using concrete cutting machine with diamond studded saw within 48 hours of casting of bay / slab etc. complete including subsequent widening of the groove 8 to 10 mm. wide at top having depth of 15 mm. as directed by Engineer incharge.

2326

-

-

... More
Providing to contraction joints polysuphide sealent (Pouring grade) confirming to BS : 5212 - 1989 into sawed groove widened at top for sealent reservoir of specified size and shape as per detailed drawing including fixing Polyethylene foam backer rod of required diameter (appraox. 25% larger than the initial 3 mOne Metric Tonneo 4 mm. joint) overlaid with bond breaking tape as per detailed drawing. Item includes cleaning the joints with water jet / air compressor and allowing joint to become thoroughly dry before sealent is applied and applying primer.(A) Contraction and longitudinal joints (15 mm. deep x 8 mm.wide)

793.4

-

-

... More
Painting Line, Dashes, Arrows etc on Roads in two coats on new work with ready mixed road marking paint confirming to I.S. 164 on Bituminous surface including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control (Over/Upto cm wide) (MORTH-803) --             SurfaceOver 10cm Wide On New Surface

18

-

-

... More
Providing and fixing of retro- reflectorised informatory sign board rectangular/Square in shape having area less than 0.9 One Square Meterr made out of         mm aluminum sheet bonded with white retro reflective sheeting of Class ( Type IV High intensity micro- prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3, supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with two coats of grey stove enamel paint and supported on one no. mild steel angle iron post 75 mm x 75 mm x 6 mm, 3.5 mt long firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing The angle iron post shall be duly painted with one coat of epoxy primer and two coats of epoxy finish paints having alternate black and white bands of 25 cm width including GI fixures and transportation etc.complete.The nut bolts of board with angle iron post/supporting structure after fixing at site has to be electrically welded. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) sheeting shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier.2mm aluminum sheet Class B

2

-

-

... More
Providing and Laying hot applied thermoplastic road marking strip on Bituminous Surface of specified shade/ colour of 2.5 mm thick including 1.5 Refractive index reflectorizing glass beads @ 250gm/sqm .Thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC 35:2015. Initial Dry reflectivity RL shall be 250 mcd/sqm/lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/sqm/ lux and Qd of 100 mcd/sqm/ lux measured at the end of 2 years by means of a Standard Reflectometer of Zehntner, Easylux, Delta make capable of measuring RL & QD both according to IRC 35:2015 clause 15.5. The finished surface to be level, uniform, and free from streaks and holes complete as per direction of Engineer-in-charge and in accordance with applicable specifications.(Refer MORTH Clause 803 for technical Specification and Performance for IRC 35:2015).

17

-

-

... More
Providing and laying concrete pipes of I.S.NP. class of 300mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars incement mortar 1:1 and refilling the trench complete.

100

-

-

... More
Stamp Concrete of 100mm Thickness - Providing and Laying in-situ M30 Grade unreinforced plain cement stamp concrete of 100mm thickness pavement over a prepared sub base with 43 grade cement, coarse and fine aggregate (natural sand / VSI grade finely washed crushed sand) Confirming to IS 383, as per mixed in a batching and mixing plant / non tilting mixer and weigh batcher as per approved mix design, admixtures, transporting to site in nagpur city with lead upto 20KM (on Inner Ring Road from Avasti nagar to wadi), spreading, laying with approved make pover, compacted and finished in a continous operation, finishing to lines and grades Also Providing, Placing and applying stamp powder which is light fast UV resistant pigment with appropriate chemical compounds of desired colour on base concrete after excess bleed water has evaporated using dry shake method @5kg per sqm. Including texturing, and covering with plastic sheet (min 200 micron thickness) and also applying two coats of UV-stable,30 % solids clear sealer @ 150 to 250 gms per sqm using surface roller and protecting from falling dust,dirt and curring by curring compound / by providing cement vata in cement Mortor 1:8 @ 0.6m x 0.6m center to center, admeasuring 80mm at bottom and 40mm at top with depth of 75mm and maintaining the same throughout curing period by any other method approved by Engineer-incharge or Landscape architect etc. complete. (prior approval of superinteding Engineer will be necessary )

4147.22

-

-

... More
Providing and laying in situ /Ready Mix cement concrete M-20 of trap / granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering formwork, laying/pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)

35.52

-

-

... More
Providing and laying weep holes of 100 mm diameter PVC pipes as per drawing for abutment returns, return walls etc. Complete.

45

-

-

... More
Providing cast in situ / ready mix M20 grade cement concrete for head walls of CD work / retaining walls etc. including necessary form work, compaction, finishing and curing etc. complete. (with reversible drum type mixer/ concrete batch mix plant (pan mixer) withSCADA

35.52

-

-

... More
Providing and laying in situ / ready mix M-20 controlled cement concrete of trap/ granite/ quartzite/ gneiss metal for RCC work in solid/ deck slab etc. including ramming, vibrating, curing, formwork, centering and finishing in cement plaster excluding reinforcement etc. complete. (with fully automatic micro processor based PLC with SCADA enabled concrete batch mix plant / pan mixer and fine agreegates of required specifications ( VSI sand finely washed etc )

23.68

-

-

... More
Geophysical / Hydrological Survey for selection of spot of Borewells/Tubewell as per the satisfaction of Engineer-in-charge. Geophysical/Hydrological Survey

2

-

-

... More
Yield Testing of borewells using90" 'V' Notch by air lift method for Half hours for successful borewell as per yielidng Borewell and installation. Yield testing of Borewell using 80"V'

2

-

-

... More
Driling of 150mm diameter Inwell vertical bore including removing the excavated material upto a distance of 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete.

160

-

-

... More
Providing casing pipe welded threaded joints medium class ERW Mild Steel block as per ISI 1239 specifications with socket and inserting in Tube well through over burden including transportation to site cutting threading & grouting the sand with cement slurry including in the cost of the coupling and plugs of 4.8mm thick etc. complete 150 mm dia perforated. providing casing pipe welded threaded joints.150 mm

120

-

-

... More
Providing and laying in trenches 80 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes of 10.15 Kilogram/metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint , 2 coats complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.

160

-

-

... More
Supplying on site fresh Garden soil (free from stones rubbish like dried grass roots, other such materials) for excavation area of depth of 20cms.( consolidated thickness).(As per P&G DSR 2022-23 Items of garden work,Sr No.38a)

1168.94

-

-

... More
Supplying on site well decomposed Farm Yard Manure for excavation area of depth of 20 cms.( consolidated thickness).(As per P&G DSR 2022-23 Items of garden work,Sr No.38b)

1168.94

-

-

... More
Providing on site well established (free from weeds /diesease etc.) ready to fix lawn turf in slabs/ rolls of required variety as directed .(As per P&G DSR 2022-23 Items of garden work,Sr No.14, item no 2)

468.94

-

-

... More
Providing on site required variety of Shrubs (free from weeds /diesease etc.) 30 cms. apart c/c.Name:-Murraya(Kamini);Bag Size 7'' x 8"(plants list) 1(a) serial no 15.

300

-

-

... More
Providing on site required variety of Hedges Well Developed, Healthy Foliage / Half Bloom Stage , Free from Pest and Diseases. apart c/c.Name:-Bougavillae Thema ;Bag Size 8'' x 10" (plants list) 7(b) serial no 10.

400

-

-

... More
Excavation for planting lawn/ shrub/ flower bed/ hedges/ edges/ canna bed in earth, soil of all types, soft murum, including removing the excavated material up to a distance of 50 mtrs.for a depth of 20 cms.(As per P&G DSR 2022- 23 Items of garden work,Sr No.5)

1168.94

-

-

... More
Mixing garden soil/silt & manure thoroughly well, watering previous night. Planting reqired plant species, lawn grass as directed etc. complete for required depth 20 cms. for planting lawn/ shrub/ flower bed/ hedges/ edges/ canna bed/ ground cover. (1/10 of semiskilledlabour)(As per P&G DSR 2022-23 Items of garden work,Sr No.23)

1168.94

-

-

... More
Maintainance of Newly Developed lawn(Instant Lawn) Area. For First 30 days only

468.94

-

-

... More
Maintainance of Newly Developed ShrubsArea. For First 30 days Only (As per P&G DSR 2022-23 Items of garden work,Sr No.31)

700

-

-

... More
Supplying on site fresh Garden soil (i. e. 3 part soil ) (free from stones rubbish like dried grass roots, other such materials) for excavated pit size area of 1 x 1 x 1m ( consolidated thickness).Quantity of soil 0.653 cum x 800/cum = 522.40/-.(As per P&G DSR 2022-23 Items of garden work,Sr No.45a)

720

-

-

... More
Supplying on site well decomposed Farm Yard Manure FYM (i. e. 1 part FYM) for excavated pit size area of 1 x 1 x 1m. ( consolidated thickness).Quantity of FYM 0.203 cum x 950/cum = 19.85/-.(As per P&G DSR 2022-23 Items of garden work,Sr No.45b)

720

-

-

... More
Providing on site Flowering Trees Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum number of Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest anddiseases,well seteled in appropriate size of Plybag,uniform in size and root system are undamaged. Apart c/c.Name:-Bahva (Amaltash);Bag Size 18 x18'', ht 8- 10'(plants list sr no1,item no 5C)

80

-

-

... More
Providing on site Flowering Trees Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum number of Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest and diseases,well seteled in appropriate size of Plybag,uniform in size and root system are undamaged. Apart c/c.Name:-Bakul;Bag Size 18 x18'', ht 8- 10'(plants list sr no2,item no 5C)

80

-

-

... More
Providing on site Flowering Trees Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum number of Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest and diseases,well seteled in appropriate size of Plybag,

80

-

-

... More
Providing on site Flowering Trees Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum number of Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest and diseases,well seteled in appropriate size of Plybag,

80

-

-

... More
Providing on site Flowering Trees Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum number of Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest anddiseases,well seteled in appropriate size of Plybag,uniform in size and root system are undamaged. Apart c/c.Name:-Kadamb;Bag Size 18 x18'', ht 8- 10'(plants list sr no5,item no 5C)

20

-

-

... More
Providing on site Flowering Trees Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum number of Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest anddiseases,well seteled in appropriate size of Plybag,uniform in size and root system are undamaged. Apart c/c.Name:-Kanchan;Bag Size 18 x18'', ht 8- 10'(plants list sr no6,item no 5C)

20

-

-

... More
Providing on site Flowering Trees Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum number of Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest anddiseases,well seteled in appropriate size of Plybag,uniform in size and root system are undamaged. Apart c/c.Name:-Kanchan;Bag Size 18 x18'', ht 8- 10'(plants list sr no6,item no 5C)

50

-

-

... More
Providing on site Foliage Trees Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum number of Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest and diseases,well seteled in appropriate size of Plybag,uniform in size and root system are undamaged.. Apart c/c.Name:-Arjuna ;Bag Size 18 x18'', ht 8- 10'(plants list sr no3,item no 6C)

60

-

-

... More
Providing on site Foliage Trees Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum number of Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest and diseases,well seteled in appropriate size of Plybag,uniform in size and root system are undamaged.. Apart c/c.Name:-Deshi Badam ;Bag Size 18 x18'', ht 8- 10'(plants list sr no4,item no 6C)

60

-

-

... More
Providing on site Foliage Trees Specification:- Minimum Girth 8 to 10 c.m. Minimum 5 to 6 Branches with Maximum number of Leaves ,clear trunk, well Developed Canopy,Healthy conditionFree from pest and diseases,well seteled in appropriate size of Plybag,uniform in size and root system are undamaged.. Apart c/c.Name:-Drooping Ashok ;Bag Size 18 x18'', ht 8- 10'(plants list sr no5,item no 6C)

110

-

-

... More
Providing on site Palms Specification:- Palm should be well Developed,Good Branching ,healthy Condition,appropriate Size in Polybag,undamaged. .. Apart c/c.Name:-Areca Palm ;Bag Size 18 x18'', ht 8- 10'(plants list sr no1,item no 11d)

40

-

-

... More
Providing on site Palms Specification:- Palm should be well Developed,Good Branching ,healthy Condition,appropriate Size in Polybag,undamaged. .. Apart c/c.Name:-Fox tail palm;Bag Size 18 x18'', ht 8- 10'(plants list sr no3,item no 11d)

40

-

-

... More
Excavation pit size 1.00 x1.00 x 1.00m for planting large flowering/ shady trees (plant height 2 to 4 mtr.)/ palm varieties of height (plant height 2 to 4 mtr.) in earth, soil of all types, soft murum, including removing the excavated & unwanted material up to a required distance of 50 mtrs. (As per P&G DSR 2022-23 Items of garden work,Sr No.12)

720

-

-

... More
Filling fresh garden soil / silt & manure in excavated pit size area of 1.00 x 1.00 x 1.00m (1/10 of unskilled labour)(As per P&G DSR 2022-23 Items of garden work,Sr No.22)

720

-

-

... More
Mixing garden soil/silt & manure thoroughly well, watering previous night. Planting reqired plant species as directed etc. complete for required pit size 1.00 x 1.00 x 1.00m.(1/10 of semiskilled labour)(As per P&G DSR 2022-23 Items of garden work,Sr No.27)

720

-

-

... More
Maintainance of Newly Planted tree varities having height 2mtr. - 4mtr. For First 30 days Only (As per P&G DSR 2022-23 Items of garden work,Srs No.35)

720

-

-

... More
Royalty Charges on Mining materials used in construction. Sand

6883.28

-

-

... More
Royalty Charges on Mining materials used in construction. Murum

127.12

-

-

... More
Royalty Charges on Mining materials used in construction. Metal

6142.25

-

-

... More
Carrying out test of Murrum transported from various sources at site in the laboratory including conveying the material to laboratory, all all labours, technician, tools and obtaining the test result form local / district/ regional laboratory etc. complete.i) Sieve Analysis

2

-

-

... More
Carrying out test of Murrum transported from various sources at site in the laboratory including conveying the material to laboratory, all all labours, technician, tools and obtaining the test result form local / district/ regional laboratory etc. complete.ii) Liqiud limit & plastic limit

2

-

-

... More
Carrying out test of Murrum transported from various sources at site in the laboratory including conveying the material to laboratory, all all labours, technician, tools and obtaining the test result form local / district/ regional laboratory etc. complete. iii) Compaction test (Proctor density)

2

-

-

... More
Carrying out test of concrete casted at site in the form of cubes of 150x150x150mm size casted during conctering in the laboratory including conveying the cubes/material to laboratory, all labours, technician, tools and obtaining the test result form local / district/ regional laboratory etc. complete. i) Compessive strength

120

-

-

... More
Carrying out Mix design with all Tests on Concrete Mix Design basic materials of concrete of various grade from the material collected at site in the laboratory including conveying all required material to laboratory, all labours, technician, tools and obtaining the test result form local / district/ regional laboratory etc. complete.

2

-

-

... More
Carrying out Basic test of Cement Standard Consistency,Fineness, Specific gravity, setting time (initial & Final)Compressive Strength,soudness in the laboratory including conveying the material to laboratory, all all labours, technician, tools and obtaining the test result form local / district/ regional laboratory etc. complete.

10

-

-

... More
Carrying out test of crusher agreegate transported from various sources at site in the laboratory including conveying the material to laboratory, all all labours, technician, tools and obtaining the test result form local / district/ regional laboratory etc. complete.i) Crushing value, ii) Impact value, iii) Specific gravity, iv) Water absorption

10

-

-

... More
Carrying out test of crusher agreegate transported from various sources at site in the laboratory including conveying the material to laboratory, all all labours, technician, tools and obtaining the test result form local / district/ regional laboratory etc. complete. v) Sieve lanalysis

10

-

-

... More
Carrying out test of crusher agreegate transported from various sources at site in the laboratory including conveying the material to laboratory, all all labours, technician, tools and obtaining the test result form local / district/ regional laboratory etc. complete. vii) Abrasion Value

10

-

-

... More
Carrying out test of crusher agreegate transported from various sources at site in the laboratory including conveying the material to laboratory, all all labours, technician, tools and obtaining the test result form local / district/ regional laboratory etc. complete. vi) Flakiness Index & Elongation Index.

10

-

-

... More
Fineness Modulus (sieve Analysi) Silt & Clay Content

10

-

-

... More
Chloride & Sulphate Content

10

-

-

... More
Silt Factor

10

-

-

... More
Carrying out various test of HYSD / TMT /FE-500 Steel transported from various sources at site in the laboratory including conveying the material to laboratory, all all labours, technician, tools and obtaining the test result form local / district/ regional laboratory etc. complete. i) Weight / metre, ii) Ultimate tensile stess, iii) Yield stress, iv) Elongation Test,a) Above 16mm dia.

15

-

-

... More
Testing of Steel Upto 16 mm (Set of 3 Bars) (Tensile strength, %, Elongation, Yield Stress,Weight-Per Meter, Bend / Rebend Test, Proof Stress.)

15

-

-

... More
Testing of Bricks for- Water Absorption (Set of 5 Bricks), Compressive Strength( Set of 5 Bricks), Efflorescence (Set of 5 Bricks).

10

-

-

... More
Testing of paving Blocks for Compressive Strength , Water Absorption,(Set of 8 Blocks)

1

-

-

... More
Testing of Wood for Density and Moisture Content

1

-

-

... More
Testing of Flush door for Knife Test, Adhesion Test, End Immersion Test.

1

-

-

... More
Testing of Aluminium section Thickness, Mass Per Running meter,

1

-

-

... More
Testing of PVC Pipe for Weight per running meter,Diameter of pipe & wall thickness of pipe, 15mm dia

1

-

-

... More
20 mm dia

1

-

-

... More
25 mm dia

1

-

-

... More
32 mm dia

1

-

-

... More
50 mm dia

1

-

-

... More
75 mm dia

1

-

-

... More
110 mm dia

1

-

-

... More
GSB Mix Design

1

-

-

... More
Carrying out Standard test of water Absorption , Flexural test on Flooring Tiles (Ceramic tiles/Vetrified tiles etc.) in the laboratory including conveying the material to laboratory, all all labours, technician, tools and obtaining the test result form local / district/ regional laboratory etc. complete.(i) Water Absorption (Set of 6 Tiles, Flextural test (Set of 6 tiles)

8

-

-

... More
Carrying out Standard test of water Absorption , Flexural test on Flooring Stones (Kota Stone/graite Stones Stones etc.) in the laboratory including conveying the material to laboratory, all all labours, technician, tools and obtaining the test result form local / district/ regional laboratory etc. complete.(i) Water Absorption (Set of 6 Tiles, Flextural test (Set of 6 tiles)

5

-

-

... More
Carrying out test of PH Value, Sulphate & Chloride Content on Water in the laboratory including conveying the material to laboratory, all all labours, technician, tools and obtaining the test result form local / district/ regional laboratory etc. complete.

1

-

-

... More
Testing of GI Pipe for Weight per running meter,Diameter of pipe & wall thickness of pipe, 15mm dia

1

-

-

... More
20 mm dia

1

-

-

... More
25 mm dia

1

-

-

... More
32 mm dia

1

-

-

... More
50 mm dia

1

-

-

... More
75 mm dia

1

-

-

... More
110 mm dia

1

-

-

... More
160 mm dia

1

-

-

... More
Supplying and erecting HMS PVC conduit FRLS grade 20 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.

3850

-

-

... More
Supplying and laying HMS PVC conduit FRLS grade 20 mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.

7560

-

-

... More
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.

2050

-

-

... More
Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.

3640

-

-

... More
Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.

1030

-

-

... More
Supplying and laying HMS PVC conduit FRLS grade 32mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.

2165

-

-

... More
Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW

8360

-

-

... More
Supplying and erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW

8360

-

-

... More
Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW

7020

-

-

... More
Supplying and erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW

7020

-

-

... More
Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW

2245

-

-

... More
Supplying and erecting mains with 1x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW

2245

-

-

... More
Supplying and erecting mains with 2x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW

460

-

-

... More
Supplying and erecting mains with 1x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW

460

-

-

... More
Supplying and erecting mains with 4x10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW

280

-

-

... More
Supplying and erecting mains with 1x10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW

280

-

-

... More
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.

1326

-

-

... More
Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete.

242

-

-

... More
Supplying and erecting modular type D.P. switch 32A with indicator, duly erected on provided plate and box with wiring connections complete.

10

-

-

... More
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.

1326

-

-

... More
Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.

252

-

-

... More
Supplying and erecting modular type computer Jack RJ45 with safety shutter, duly erected on provided plate and box with wiring connections complete.

242

-

-

... More
Supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete.

540

-

-

... More
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.

242

-

-

... More
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.

40

-

-

... More
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.

296

-

-

... More
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.

242

-

-

... More
Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/CW

678

-

-

... More
Point wiring for light/bell/exhaust fan in 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW.

160

-

-

... More
Point wiring for light/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/HW

720

-

-

... More
Point wiring for ceiling fan (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/HW

540

-

-

... More
Wiring for plug on board with Switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WG-PW/CW

390

-

-

... More
Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC

16970

-

-

... More
Supplying and erecting LSZH armoured multimode optical fibre cable with 6 fibres, core dia 50/125 µm (OM3), suitable upto 10 GBPS, ethernet distance at 850 nm of wavelength, on wall/ceiling or laid in provided pipe/trench as per specification no. WG-COC/OFC LSZH

2800

-

-

... More
Supplying and installing armoured single mode optical fibre cable with 6 fiber, core dia 50/125μm (OS1/OS2) 10/40 GBPS speed in provided underground HDPE pipe complete.

1140

-

-

... More
Supplying and fixing 1 m length, UTP patch cord of enhanced Cat 6 type with 4-connector channel, performance test report as per ANSI/TIA-568.2-D in position as per specification No. WG-COC/PC

250

-

-

... More
Supplying, fixing, and configuring 24 ports with 4 (SFP+) port, ethernet managed switch with web view/CLI, 6KV surge protection on ethernet port and console port for management in provided rack as per specification no. WG-NWC/GBS

24

-

-

... More
Supplying, fixing, and configuring broadband ADSL router with all accessories, on provided rack as per specification No. WG-NWC/ADSL

16

-

-

... More
Supplying and fixing 9U wall mount rack (Dimension-DxWxH – 500x600x500 mm) as per specification No. WG-NAS/RAK

16

-

-

... More
Supplying and erecting LED Panel Light(600mm X 600mm) Max. 35 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min 4200 Lumens, min. efficacy of 120 lumen/W, CRI80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD10%, p.f. 0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.

720

-

-

... More
Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI80, CCT upto 6500K, Beam Angle of 120 deg., THD10%, p.f. 0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty.

130

-

-

... More
Supplying and erecting anodized aluminium corridor / passage / mirror light LED fitting (2 feet) Max. 12W with high transitivity diffuser with min. system lumens output of 1200 lumens, min. efficacy of 100 lumen/W, CRI80, CCT upto 6000K, Beam Angle of 110 deg., Ripple5%, THD10%, p.f. 0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver with end caps on provided PVC Block / wooden board with 3 years warranty.

26

-

-

... More
Supplying and erecting CRCA powder coated corridor/passage light LED fitting (4 feet) Max. 17W with high transitivity diffuser with system lumens output of Min. 2000 lumens , min. efficacy of 120 lumen/W, CRI80, CCT upto 6500K, Beam Angle of 120 deg., Ripple5%, THD10%, p.f. 0.95, operating range of 120-270V, surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty.

510

-

-

... More
Supplying and erecting ding dong / electronic musical type call bell with heavy duty coil suitable to operate on 230V A.C. supply erected on polished double wooden block/sunmica block of suitable size.

22

-

-

... More
Supplying and erecting integrated LED street light fitting 40 to 50W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 4400 Lumens, min. efficacy of 110 lumen/W, CRI70, CCT upto 6500K,THD10%, p.f. 0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2.

6

-

-

... More
Supplying and erecting integrated LED flood light fitting Max. 100W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 12000 Lumens, min. efficacy of 120 lumen/W, CRI70, CCT upto 6500K, THD10%, p.f. 0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2.

6

-

-

... More
Supplying and erecting street light Wall bracket made from 25 mm. dia ‘ G.I. pipe 1.2 m. in total length complete as per specification no. FG-BKT/WB

6

-

-

... More
Supplying and erecting exhaust fan medium duty 230 V A.C. 50 cycles 225 mm. 1400 RPM with condenser complete erected in position with necessary materials. Fan motor with moisture proof treatment and ‘E’ class insulation.

160

-

-

... More
Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of 28W having service ratio (CMM/W) of Min. 8 , PF0.9, THD10% with IR remote control/compatible speed regulator, Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF (Without Remote)

540

-

-

... More
Supplying and erecting fan hook box of 10 mm M.S. round bar bounded to the R.C.C. bars upto 50 mm length each side and pierced through a 16 S.W.G. thick aluminium/M.S. Bowl 100 mm dia. or equivalent square size and having depth upto 75 mm complete erected with duly painted by one coat of red oxide paint and two coats of paint erected in position and without any leakage of slurry of cement concrete on either side of the box and positioned to the bottom level of the slab.

540

-

-

... More
Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire.

540

-

-

... More
Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor. room air conditioning unit 1.7TR to 2.0TR capacity having ISEER minimum 5.0 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position in provided recess with wooden frame complete specification no. AP-AC/WAC

10

-

-

... More
Supplying, erecting, testing and commissioning self contained water cooler 230/250V 50Hz nominal cooling capacity of 80 litres per hour and storage capacity 120 litres with partially stainless steel body as per specification no. AP-WCR/WC

5

-

-

... More
Supplying and erecting ultra violet water purifier with softener for safe drinking water consisting of UV germicidal tube of 8W capacity, choke made of copper wire, two indicator lamps, dual function cartridge with output of purified water 1 litre/min with activated carbon filter and softener operating on 230V, single phase A.C. supply with UV fail & filter change indication system.

5

-

-

... More
Supplying, erecting, testing and commissioning of 6kVA capacity online pure sine wave with backup time of 2 hrs. PWM & IGBT based UPS with 0.9 to unity output pf, single phase input & 1 phase output complete with all protections as per specification no. AP-UPS

16

-

-

... More
Supplying, erecting, testing and commissioning of 10kVA capacity online pure sine wave with backup time of 2.5 hrs. PWM & IGBT based UPS with 0.9 to unity output pf, 3 phase input & 1 phase output complete with all protections as per specification no. AP-UPS

4

-

-

... More
Supplying and erecting 12V/100Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete.

122

-

-

... More
supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 15.9 mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete.

50

-

-

... More
supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 12.7mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete.

50

-

-

... More
Supplying & erecting four pole ON LOAD change over switch, 415V, 315-320A, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, operational current category AC23A complying to IS/IEC 60947-3 Part-1/3.

1

-

-

... More
Supplying and erecting switch disconnector fuse (SDF) 415V, 300-320A, with enclosure, four pole and neutral link AC23 A rated with terminal shrouds on both sides and phase barriers along with telescopic shaft for depth adjustments and door interlock and padlock complying to IS/IEC 60947-3 Part-1/3 HRC - DIN type fuse switch, insulation voltage 1000 V, with rotary handle for ON / OFF operation (without HRC fuse)

1

-

-

... More
Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

360

-

-

... More
Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

360

-

-

... More
Supplying, erecting & marking TPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

36

-

-

... More
Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 4 ways/phase (12 poles), with door, 1.2mm thickness, surface/flush mounted, IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB

60

-

-

... More
Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 4 ways /12 Poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB

12

-

-

... More
Providing & erecting 3 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB

36

-

-

... More
Providing & erecting 3 Pole MCCB, 415V, 200A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB

18

-

-

... More
Providing & erecting 3 Pole MCCB 415V, 400A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure /panel as per specification no. SW-SWR/MCCB

1

-

-

... More
Supplying, fixing and commissioning 4 pole RCBO 6/10/16/20/25A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indications per specification no SW-RCCB/RCBO

30

-

-

... More
Supplying, fixing and commissioning 4 pole RCBO 32/40A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO

20

-

-

... More
Providing & erecting floor/wall mounting, MCCB panel board, with door, suitable for four pole incoming 250A, 6 ways four pole outgoing, up to 100 A MCCBs on iron frame, as per specification no SW-SWR/MCCBPB. (Excluding MCCBs)

6

-

-

... More
Providing & erecting floor/wall mounting, MCCB panel board, with door, suitable for four pole incoming 400A, 12 ways four pole outgoing, up to 100 A MCCBs on iron frame, as per specification no. SW-SWR/MCCBPB. (Excluding MCCBs)

1

-

-

... More
Providing & erecting incoming and outgoing cable alleys suitable for MCCB panel board with door, 250A incoming and 6 way outgoing or 400A incoming and 4 way outgoing made from CRCA sheet 1.6 mm thick duly powder coated and having vertical insulated partition for shielding between the shared face of cableway and DB.

6

-

-

... More
Providing & erecting incoming and outgoing cable alleys suitable for MCCB panel board with door, 400A incoming and 12 way outgoing made from CRCA sheet 1.6 mm thick duly powder coated and having vertical insulated partition for shielding between the shared face of cableway and DB.

1

-

-

... More
Supplying & erecting HRC fuse cartridge 415V, 300A

3

-

-

... More
Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete.

15

-

-

... More
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.

560

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

1600

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

1600

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 95 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

210

-

-

... More
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.

900

-

-

... More
Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 100 mm height comprising all required standard accessories.

1400

-

-

... More
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP

10

-

-

... More
Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP

20

-

-

... More
Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete.

270

-

-

... More
Supplying & erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation complete.

6

-

-

... More
Providing printed instruction chart for treating persons suffering from electric shock, printed in English & Marathi and duly laminated complete.

20

-

-

... More
Supplying standard first aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use, scissors, anti-septic solution, etc. (All above contents shall be of standard makes)

6

-

-

... More
Supplying and fixing PVC synthetic elastomer electrically insulating mat with class A insulation conforming to IS: 15652 – 2006 having 2 mm thickness up to 3.3 kV

45

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 95 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

90

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

360

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

100

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 35 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

180

-

-

... More
Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 200 mm width & 100 mm height comprising all required standard accessories.

130

-

-

... More
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP

2

-

-

... More
Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP

8

-

-

... More
Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete.

60

-

-

... More
Supplying, installation, testing and commissioning of main fire pump (MFP / EP) suitable for water discharge of 2280 to 2850LPM at 80 to 60 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 45kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal type, single stage, centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/EP (Main + Sprinkler + Standby)

3

-

-

... More
Supplying, installation, testing and commissioning of jockey fire pump (JP) suitable for water discharge of 180 to 240 LPM at 110 to 90 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 11 kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal/vertical type, multi stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/JP

2

-

-

... More
Supplying, installation, testing and commissioning of booster fire pump [BP] suitable for water discharge of 450 LPM at 35 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 5.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal/vertical type, single/multi stage, centrifugal casing pump of cast iron body & bronze/CI impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/BP

2

-

-

... More
Supplying, installation, testing and commissioning of main fire pump (MFP/DP) suitable for water discharge of 2280 to 2850 LPM at 120 to 90 m head driven by 110 HP or suitable HP capacity diesel engine at required working speed suitable for automatic operation and consisting of following : (a) Horizontal type, single stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520. (b) Water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12/24 volts DC electric starting equipment with battery of required AH capacity with necessary charger suitable to work on 230v, 50Hz AC supply, diesel tank of minimum 150ltr capacity with first filling of diesel up to 100% level with necessary piping with valves up to engine , exhaust pipe extended up to 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications etc. as required. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with engine assembly and accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/DP

1

-

-

... More
Supplying, erecting, testing & commissioning of fire pump control panel (FCP) of cubical construction, floor mounted type, fabricated from minimum 2 mm thick CRCA sheet, compartmentalised with hinged lockable doors, with enclosure protection class IP54, duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnection with suitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessories, mountings and internal wiring with adequate size copper conductor cable, earth terminals, numbering etc. complete in all respect, suitable for satisfactory operation of main fire pump and jockey (pressurisation) pumps (1working+1standby) with necessary accessories, wiring & cabling along with allied accessories with following incoming and outgoings, suitable for automatic & manual operation on 415V, 3 phase, 50Hz ac supply as per specifications the capacity of electric motor driven pump are as follows a. Main fire pump(MFP) having capacity of 22kW 1no (1 working) b. Jockey pump(JP) capacity of suitable capacity 2 nos(1 working +1 standby, alternate run per start in auto mode) comprises of the following features & switchgears: 1. Main incomer FP SFU having rotary handle with HRC fuses of suitable rating. 2. Electrolytic grade copper strips for busbar of suitable sizes for main incomer and branches to motor SFU's, starters & outgoing terminals with necessary accessories like stainless steel nut bolts with spring washers for connections, mounted on required no of epoxy or porcelain support insulators of suitable ratings etc. 3. Individual pump TPN SFU having rotary handle with HRC fuses of suitable rating. 4. Digital voltmeter & ammeter & RYB indicating lamps & push buttons & SPP, O/L & phase reversal protection with emergency stop switch. 5. TPN SPD 100kA Type 1 +2 tested. 6. Required pressure transducer with pressure indication on panel with cabling required for monitoring & automatic operation of fire pumps. 7. System controller to control operation of main electric fire pump, jockey (pressurization) pumps in sequence with interlocking for operation of pumps as per specification with automatic/manual operation with selector switch & alternate run of standby Pumps consisting of relays, timers. sensors, annunciation window for fault indication, complete as per specification. 8.Suitable capacity electric motor starters for all individual pumps with necessary push buttons & indications. 9. Siren of required capacity to be activated when main pump starts & allied accessories as per requirements of local CFO or as directed by engineer in charge. 10. Danger board as per IS. 11. Spare HRC fuses minimum 2nos of each individual rating with required bakelite fuse holder for main & jockey fire pumps MFP=(1working), JP = (1working+1standby, alternate run per start in auto mode) complete panel, as per specification no. FF-MFP/ECP Add Ons:-A-3)For main electric motor driven fire hydrant system pump of 45kW capacity & relevant capacity jockey pump add Rs 47686 B-4)For main electric motor driven fire sprinkler system pump of 45kW capacity (1Working) & relevant capacity jockey pumps (1working+1standby, alternate run per start in auto mode, add Rs 200564 C-4)For standby main electric driven fire hydrant/sprinkler system pump of 45kW capacity, add Rs 37184 D)For addition of standby main diesel engine driven fire pump (1 standby), add as follows in the basic cost of Item no 13-5-1 towards required 12/24 v battery charger and diesel engine starter along with necessary accessories, indicators etc. with necessary interlocking and updation of control logic with interlocking for operation of pumps MFP for main (1working+1standby mode) & jockey fire pumps (1working+1standby, alternate run per start in auto mode) , add Rs 68381/- The control for diesel engine comprises of automatic/manual selector switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode indicating lamp for high/ low Lub. oil pressure, high water temp and engine on indication battery charger suitable for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC voltmeter, and 0-20 A DC ammeter with all standard relays and accessories required for automatic operation of diesel engine with interlocking for operation of main fire pumps E-1)for 5.5/ 7.5 kW centrifugal type booster pump 1no(1working) , add Rs 18893.70 Total:- FCP + A-3 + B-4 + C-4 + D + E-1 = 182320+47686+200564+37184+68381+17994 =5,54,129/-

1

-

-

... More
Supplying and erecting G.I. pipe ‘C’ class ERW 25 mm dia with necessary fittings complete as per specification no. FF-PP

2800

-

-

... More
Supplying and erecting G.I. pipe ‘C’ class ERW 50 mm dia with necessary fittings complete as per specification no. FF-PP

1200

-

-

... More
Supplying and erecting G.I. pipe ‘C’ class ERW 75/80 mm dia with necessary fittings complete as per specification no. FF-PP

360

-

-

... More
Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm dia with necessary fittings complete as per specification no. FF-PP

1600

-

-

... More
Supplying and erecting G.I. pipe ‘C’ class ERW 150 mm dia with necessary fittings complete as per specification no. FF-PP

540

-

-

... More
Supplying and erecting G.I. pipe ‘C’ class ERW 200 mm dia with necessary fittings complete as per specification no. FF-PP

100

-

-

... More
Supplying and erecting 100 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS

2

-

-

... More
Supplying and erecting 100 mm dia. cast iron double flange sluice valve complete with PN16 pressure rating, as per specification no. FF-VL/SV

2

-

-

... More
Supplying and erecting 50 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV

22

-

-

... More
Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV

12

-

-

... More
Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV

4

-

-

... More
Supplying and erecting 100 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV

6

-

-

... More
Supplying and erecting 50 mm dia gun metal gate valve complete with PN16 pressure rating, as per specification no. FF-VL/GV

26

-

-

... More
Supplying and erecting stainless steel single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV

44

-

-

... More
Supplying and installing wall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) along with necessary accessories complete as per specification no. FF-FFA/HV

40

-

-

... More
Supplying and erecting 63mm dia, reinforced rubber lined (R.R.L.) hose pipe, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL

84

-

-

... More
Supplying and erecting stainless steel branch pipe 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specifications no. FF-FFA/NZ

44

-

-

... More
Supplying and erecting fire brigade header ( Siamese connection )of 150 mm dia, for supplying water in fire tank complete as per specification no. FF-FA/FMC

2

-

-

... More
Supplying and erecting 300 mm dia 1.5m in height air vessel / tank fabricated from min 5mm thick M.S. sheet complete as per specification no. FF-FFA/ACT

1

-

-

... More
Supplying and erecting 20/25mm dia gun metal air release cock, with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV

4

-

-

... More
Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, erected with provided G.I. pipe, elbow etc. complete as per specification no. FF-FFA/PG

6

-

-

... More
Supplying and erecting 12/15 mm dia pressure switch with provided isolation valve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS

4

-

-

... More
Supplying and erecting M.S./CRCA cabinet for housing Floor Hydrant valve, hose pipe, hose reel and branch pipe (size 1000 x 736 x 736 mm.) made from 16 SWG sheet and angle iron 25 x 25 x 4 mm. having front doors with viewing glass (8"x6") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5)

44

-

-

... More
Supplying, installing, testing and commissioning FR, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU

4200

-

-

... More
Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the 4 loop capacity and capable of supporting upto 250 devices and detectors per loop, with on-board LCD display with min 16 lines of text, operating at 230 V 50 HZ - AC with inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 min in alarm condition, suitable provision for network connectivity, interfacing with third party equipment via a MODBUS/ OPC/ L-ON interface etc. conforming to IS 15908:2021, ,IS 2189: 2008, EN 54 & VDS / FM/ UL 864 (10th edition) with 3 years replacement warranty FF-AFAS/CP.

1

-

-

... More
Supplying, installing, testing and commissioning of addressable optical smoke detector, single/twin LED’s with 360 degree view, suitable for low voltage 15 to 32 V DC two wires supply, in-built locking mechanism to check the removal and pilferage of the detector, in built isolation mode, start up current 300µA and alarm condition current shall be maximum 6.5 mA, operating temperature 0°C to 50°C, humidity 0-95% RH, IP 41, conforming to IS 2189: 2008, 11360_1985_Reff2020 EN 54 or UL Approved with 3 years equipment replacement warranty FF-AFAS/SD .

910

-

-

... More
Supplying, installing, testing and commissioning of addressable manual call points ( break glass type/pull station type), made of addressable break glass plastic square in shape surface/flush mounted with "Break Glass" massage embedded on the glass, complete erected with mounting base and required accessories conforming to EN 54 or UL listed with 3 years equipment replacement warranty FF-AFAS/MCP.

30

-

-

... More
Supplying, installing, testing and commissioning of addressable fire control/relay module complete as required, with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 reed relays, EN 54 or UL Listed FF-AFAS/CRM

30

-

-

... More
Supplying, installing, testing and commissioning of addressable horn cum strobe sound/ hooter, output frequency 500 to 1000 Hz with dB as per Chart given in IS 15908:2021, with flashing at 1 Hz over the strobe’s entire operating voltage range EN 54, conforming to IS 2189: 2008, IS 15908:2021 standards with 3 years equipment replacement warranty FF-AFAS/SSH.

30

-

-

... More
Supplying, erecting, testing and commissioning 120 W amplifier suitable to operate on 230 Volts A.C. / 12 Volts D.C. supply complete as per specification no. FF-PA/AFR

1

-

-

... More
Supplying, erecting, testing and commissioning 15 to 30 Watts sound column or ceiling mounted complete as per specification no. FF-PA/SOC

10

-

-

... More
Supplying, erecting, testing and commissioning stand mounted/handheld type wired microphone having 2 mV/Pa sensitivity, impedance level limit 300 ohms and 50 - 16000 Hz suitable to operate in -10 deg C to +55 deg C with min. 7 metre shielded cable and 3 Pin Professional XLR Connector, stereo jack complete as per specification no. FF-PA/MIC

1

-

-

... More
Supplying, erecting, testing and commissioning of 0.5 sq. mm speaker wire complete.

600

-

-

... More
Supplying, erecting, testing and commissioning of quartzoid bulb sprinkler, 15 mm (½") dia. NBCM Body chrome finished, 68º C fixed temperature rating with deflector disc of conventional construction complete as per specification no. FF-SPR.

1800

-

-

... More
Supplying, erecting, testing and commissioning vane type water flow detector 100 mm dia. with 1) Visual switch activation 2) Rugged switch assembly 3) Heavy duty aluminium pipe saddles 4)Durable metal enclosure 5) Steel U bolts for secure mounting 6) Two SPDT ( Single pole double track ) synchronised switches 7) serviceable without draining pipes.

3

-

-

... More
Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete.

40

-

-

... More
Supplying and erecting ABC powder type fire extinguisheras per IS : 13849 /15683 of 6 kg capacity with necessaryclamp for erection on wall.

96

-

-

... More
Supplying & installation auto glow/self Luminous (Viewing upto 15 mtr length) fire signages Fire Exit, Fire Hydrant,Hose Box, MCP, Hooter, Fire Alarm Control Panel & Fire Exinguisher signage Indicating the detail. With BS5499 as per sample approved by incharge.

100

-

-

... More
Supplying, installing, testing and commissioning of 25 kWp ON-GRID Solar PV System / Plant consisting Solar PV Poly Crystalline Panel (335 Wp X 75 Nos.) and Solar ON-GRID Inverter of similar capacity (THD3%) with interconnecting wires / cables up to solar ON GRID inverter, proper base plate, canopy box to house Inverter and necessary accessories i.e. ACDB/ DCDB , MCB etc. wiring up to solar Inverter in casing and capping, display board, sign board, two distinct earthing, lightning arrester, liaisoning charges, remote monitoring system with maintaining card / chip for 5 years including net charges for RMS System, complete up to net meter installation and export to the grid with 5 year ON-SITE warranty and fully comprehensive maintenance contract as per Specification no. ESD-RT-ONG.

1

-

-

... More
Supplying and erecting switch disconnector fuse (SDF) 415V, 160A, with enclosure, four pole AC23 A rated with terminal shrouds on both sides and phase barriers along with telescopic shaft for depth adjustments and door interlock and padlock complying to IS/IEC 60947-3 Part-1/3 HRC - DIN type fuse switch, insulation voltage 1000 V , with rotary handle for ON / OFF operation(without HRC fuse)

1

-

-

... More
Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete.

3

-

-

... More
Supplying and erecting marine (Waterproof) plywood 18/19 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners, supports, nut bolts etc. complete with compliance to IS 720:2010FR plywood with compliance to IS 5509:2000

1

-

-

... More
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.(Mono Rails 75x3 = 225Nos, 3KG x 225 = 675KG)

1555

-

-

... More
Supplying and erecting static energy Trivector meter 440 V 50 Hz. 20-100A ISI mark meter AC 3 phase 4 wires LCD/LED display (Measuring and display Trivector, V, I, kW, PF, Hz, Last month history of kWh & MD in kW) with special features like TOD, Tamper logging, Optical Communication Port & Display in absence of Power complete erected on polished teak wood board duly wired with required size of weather proof PVC wires duly tested for class 1.0 accuracy by electric supply company. (Use as Solar Generation Meter)

1

-

-

... More
Supplying and erecting AC three phase HT CT multifunction net meter DLMS compliance of accuracy class 0.5, 3x 63.5V, 50Hz, with backlit LCD display, optical port & RS 232 port( measures import kWh, kVAh, export kWh, kVAh, net kWh, kVAh, V, I, kW, 6 months history of energy, load survey, TOD, tamper detection & logging, power ON/OFF events, instantaneous parameters of rating 1/5A with display in absence of power) with wiring connections and mounting hardware on provided panels complete with calibration certificate from manufacturer.

1

-

-

... More
Making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose).

15

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 185 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

120

-

-

... More
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 200 mm outside dia, double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.

100

-

-

... More
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP

4

-

-

... More
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.

5

-

-

... More
Supplying, erecting, testing and commissioning of diesel generating set with alternator of 200 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 1 %, with performance class G2 and maximum fuel consumption 34.40 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 1.4/1.5 mm thickness MS Sheet, sound absorbing material to restrict sound level up to 75 dB(A) at 1.0 m, provided with first filling of oil, diesel not less than 300 Ltr etc. on provided M20 Grade CC Foundation, complying to CPCP IV norms with STD AMF panel complete. Approved by SE Office Nagpur Vid letter no.520 Dt.20/02/2024.

1

-

-

... More
Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 180 kVA up to 200 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF. (185054-10% = 166548.60)

1

-

-

... More
Excavating soft murum / soft soil road by chiselling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site good complete.

2

-

-

... More
Making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose).

20

-

-

... More
Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.

250

-

-

... More
Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.

160

-

-

... More
Supplying and erecting PVC insulated PVC round sheathed 4 sq.mm (56 no. x 0.30 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV (For IDU)

430

-

-

... More
Supplying and erecting modular type D.P. switch 32A with indicator, duly erected on provided plate and box with wiring connections complete.

18

-

-

... More
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.

18

-

-

... More
Supplying, erecting, testing and commissioning of 7HP to 8HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000m operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete.

5

-

-

... More
Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact/standard size) of nominal cooling capacity 2.0TR (618 cfm) to 2.3TR (671 cfm) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation.

24

-

-

... More
Supply, installation, testing and commissioning wireless remote control having colour LCD panel, real time clock, temperature limitation (16 to 30° C, functions like filter clean reminder timer suitable to communicate with wired controller complete.

24

-

-

... More
Supplying and installation of high pressure grade required size copper connection Y or T- Joints/refnet complete erected on wall/ceiling with supports/raceways, Nitrile rubber insulation, painting etc. with brazing and testing for leakages confirming the normal operation of the VRV/VRF air conditioning system.

48

-

-

... More
supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 22.2mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiation with OEM standards of VRV/VRF air conditioning system complete.

360

-

-

... More
supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 19.1mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete.

360

-

-

... More
supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 12.7mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete.

200

-

-

... More
Supplying and erecting 12/16 mm (ID/OD) Chlorinated polyvinyl chloride pipe (CPVC), thickness 1.7 mm conforming to IS 15778 (CTS Series) with necessary CPVC fittings and solvent cement for Solar Water Heater System as per specification No. ESD-HWP/CPVC

200

-

-

... More
Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

27

-

-

... More
Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

9

-

-

... More
Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 4 ways/phase (12 poles), with door, 1.2mm thickness, surface/flush mounted, IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB

3

-

-

... More
Supplying, erecting & commissioning 4 pole RCCB 63A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB

3

-

-

... More
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.

210

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU

310

-

-

... More
Supplying, installation and testing of maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete, and recording the results Specification no. EA-MOBI

3

-

-

... More
Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete.

20

-

-

... More
Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV

260

-

-

... More
Supplying and erecting integrated LED street light fitting 70-75W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 7700 Lumens, min. efficacy of 110 lumen/W, CRI70, CCT upto 6500K,THD10%, p.f. 0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2.

40

-

-

... More
Supplying & erecting three phase, 415V, street light control panel up to the max load of 6kW, TPN MCB 40A, powder coated CRCA 14 SWG sheet, outdoor type, having IP54,IK10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protection on provided iron frame / CC foundation.

2

-

-

... More
Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

40

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

1400

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

60

-

-

... More
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.

1300

-

-

... More
Providing & erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL

40

-

-

... More
Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT

40

-

-

... More
Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP

40

-

-

... More
Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete.

5

-

-

... More
Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole).

30

-

-

... More
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.

180

-

-

... More
Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW

360

-

-

... More
Supplying and erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW

360

-

-

... More
Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW

180

-

-

... More
Supplying and erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW

180

-

-

... More
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.

30

-

-

... More
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.

30

-

-

... More
Supplying and erecting PVC Surface modular switch box with double mounting plate for 4 module duly erected.

30

-

-

... More
Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI80, CCT upto 6500K, Beam Angle of 120 deg., THD10%, p.f. 0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty.

30

-

-

... More
Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

24

-

-

... More
Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB

6

-

-

... More
Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame.

6

-

-

... More
Supplying, erecting & commissioning 2 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB

4

-

-

... More
Supplying, erecting & commissioning 2 pole RCCB 63A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB

2

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

360

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

190

-

-

... More
Supplying & erecting G.I. pipe ‘A’ class 25 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE

40

-

-

... More
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP

6

-

-

... More
Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP

6

-

-

... More
Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete.

15

-

-

... More
SITC of Electric Traction Passenger Lift with ·       Rated capacity :- 8 Passenger/544Kg ·       Floors :- G+5 floor (6 Stops/6 Landings) ·       Travel :- 3 to 4.2 mtrs·       Location of Lift Machine:- MR/MRL ·       Rated speed :- 1.0 mps VS ·       Car/Landing door clear opening of 800 mm wide x --------- For Detaiiled wording Refer Tender Booklete

4

-

-

... More
For Lift having 1000mm wide x 2000mm high clear entrance in 1.5mm thickSS 304 grade solid(non-cladded) landing door [Two panel], this includes all necessary accessories like LOP's with UP/DN buttons-arrows-indicators,extension of guide rails, shaft wiring with trunking, travelling cables, main hoisting ropes/belts, & OSG rope landing doors with all accessories etc. necessary for the normal safe functioning of lift installation complete.

4

-

-

... More
For Full Collective control system,For Lift travelling above First floor & up to Sixth floor (Base Rate 27340 x 4 Nos Lifts = 1,09,360/-)

1

-

-

... More
SITC of Duplex Lift control system for two nos. microprocessor/PLC based simplex lift controllers along with necessary software with programming and hardware e.g. logic board, necessary communication/control/data cabling laying in rigid PVC conduits/trunking etc. complete.

2

-

-

... More
Supplying and erecting HMS PVC conduit FRLS grade 20 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.

1260

-

-

... More
Supplying and erecting PVC insulated PVC round sheathed 1 sq.mm (32 no. x 0.20mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV

120

-

-

... More
Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC

2230

-

-

... More
Supplying, fixing, and configuring 8-ports managed gigabit, Layer-2 switch, 10/100/1000 base-T, POE smart switch plus 2 SFP erected in provided rack complete.

12

-

-

... More
Supplying, erecting, testing and commissioning of 3kVA capacity online pure sine wave with backup time of 6 hrs. PWM & IGBT based UPS with 0.8 to unity output pf, single phase input & 1 phase output complete with all protections as per specification no. AP-UPS

1

-

-

... More
Supplying and erecting 12V/42Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete

4

-

-

... More
Supplying & erecting of High definition 4/5 Megapixel IP IR Bullet Camera with following featuresImage Sensor : minimum 1/2.8" Progressive Scan CMOS, Video Resolution : minimum 2592 x 1520Video Compression : H.264, H.265 or higher, at least Three individually configurable stream, Frame rate : minimum 25 fps at all resolutions, WDR : minimum 120 dB Wide Dynamic Range, ONVIF profile conformant, minimum IR distance : 50m, Lens Type : 2.8/4/6 mm Lens, fixed focal, Field of View :2.8 mm, horizontal FOV 107°, vertical FOV 57°, diagonal FOV 129°4 mm, horizontal FOV 86°, vertical FOV 47°, diagonal FOV 102° 6 mm, horizontal FOV 55°, vertical FOV 29°, diagonal FOV 65°Lux sensitivity - minimum 0.2 Lux at color, minimum 0.05 Lux at Black & White, 0.0 Lux (IR) Night Vision Distance minimum IR - 50m. Camera minimum Adjustment Angles - Pan : 350°, Tilt : 72°, Rotate : 350°. Power Supply : Support 12VDC & PoE, IP67, IK10 - Vandal Resistant.Built in micro SD/SDHC/SDXC card slot of minimum 128 GB, Built in microphone. minimum Input/Output - Audio in × 1, Audio Out × 1, Alarm in × 1, Alarm Out × 1. Image Settings : Rotate mode, saturation, brightness, contrast, sharpness, gain, white balance. Image Enhancements : Day/Night-Auto (ICR)/Color/Black & White, 3D Digital Noise Reduction, Automatic White Balance, Automatic Gain Control, Backlight Compensation, Highlight Compensation.Events : Privacy Masking, Motion detection, Scene change detection, Face capture, Video tampering, audio exception detection, Region entrance detection, Region exiting detection. Operating temperature ( -30 to 60° C ) . Security - User account and password protection, HTTPS, IP filter, IEEE 802.1X, digest authentication, user access log, TLS1.2, AES - 256, SSH/Telnet closed, FTP disabled. Protocol - DHCP, UDP, HTTP, HTTPS, NTP, DNS, RTP, RTSP, SMTP, SSL/TLS, TCP/IP, Secure Real-Time Transport Protocol (SRTP), Bonjour, SNMP and Secure shell (SSH) supported protocol. RoHS, WEEE, ISO-14001 and REACH compliant, UL/EN OR equivalent BIS/TECH/STQC or any indian standards as applicable, CE, FCC certified. duly erected in position on wall/ceiling/false ceiling/provided pole (mounting height not more than 5 meter) etc with all accessories etc complete as per specification no. CCTV-CAM (NCSR Rates Approved By SE Office Nagpur Vid. Letter No. 1226 Dt 20/05/2024)

8

-

-

... More
Supplying & erecting of High definition 4/5 Megapixel IP IR Dome Camera with following features Image Sensor : minimum 1/2.8" Progressive Scan CMOS, Video Resolution : minimum 2592 x 1520 Video Compression : H.264, H.265 or higher, at least Three individually configurable stream, Frame rate : minimum 25 fps at all resolutions, WDR : minimum 120 dB Wide Dynamic Range, ONVIF profile conformant, minimum IR distance : 50m, Lens Type : 2.8/4/6 mm Lens, fixed focal, Field of View :2.8 mm, horizontal FOV 107°, vertical FOV 57°, diagonal FOV 129° 4 mm, horizontal FOV 86°, vertical FOV 47°, diagonal FOV 102°6 mm, horizontal FOV 55°, vertical FOV 29°, diagonal FOV 65°Lux sensitivity - minimum 0.2 Lux at color, minimum 0.05 Lux at Black & White, 0.0 Lux (IR) Night Vision Distance minimum IR - 50m. Camera minimum Adjustment Angles - Pan : 350°, Tilt : 72°, Rotate : 350°. Power Supply : Support 12VDC & PoE, IP67, IK10 - Vandal Resistant. Built in micro SD/SDHC/SDXC card slot of minimum 128 GB, Built in microphone.minimum Input/Output - Audio in × 1, Audio Out × 1, Alarm in × 1, Alarm Out × 1. Image Settings : Rotate mode, saturation, brightness, contrast, sharpness, gain, white balance. Image Enhancements : Day/Night-Auto (ICR)/Color/Black & White, 3D Digital Noise Reduction, Automatic White Balance, Automatic Gain Control, Backlight Compensation, Highlight Compensation. Events : Privacy Masking, Motion detection, Scene change detection, Face capture, Video tampering, audio exception detection, Region entrance detection, Region exiting detection. Operating temperature ( -30 to 60° C ) . Security - User account and password protection, HTTPS, IP filter, IEEE 802.1X, digest authentication, user access log, TLS1.2, AES - 256, SSH/Telnet closed, FTP disabled. Protocol - DHCP, UDP, HTTP, HTTPS, NTP, DNS, RTP, RTSP, SMTP, SSL/TLS, TCP/IP, Secure Real-Time Transport Protocol (SRTP), Bonjour, SNMP and Secure shell (SSH) supported protocol. RoHS, WEEE, ISO-14001 and REACH compliant, UL/EN OR equivalent BIS/TECH/STQC or any indian standards as applicable, CE, FCC certified. duly erected in position on wall/ceiling/false ceiling/provided pole (mounting height not more than 5 meter) etc with all accessories etc complete as per specification no. CCTV-CAM (NCSR Rates Approved By SE Office Nagpur Vid. Letter No. 1226 Dt 20/05/2024)

12

-

-

... More
Supplying & erecting of High definition 4/5 Megapixel IP IR PTZ Camera with following features Image Sensor : minimum 1/2.8" Progressive Scan CMOS Video Resolution: minimum 2880 x 1620 Video Compression : H.264, H.265 or higher, at least Three individually configurable stream, Frame Rate : minimum 30 fps at all resolutions, WDR : minimum 120 dB Wide Dynamic Range, ONVIF profile conformant. Auto Tracking, Pre-set Tour Settings, Pan : 360° endless, Tilt : From -15° to 90° (auto-flip 180°), minimum Pan Speed - from 0.1°/s to 160°/s, minimum Preset Speed: 240°/s, minimum Tilt Speed - from 0.1°/s to 120°/s, minimum Preset Speed : 200°/s, Min Presets- 250, Min IR distance :150m,Lens Type : minimum 4.3 - 12.5mm Lens min 16 x digital zoom, min 30 x optical Zoom. Focus Mode : Auto/Zooming/One Push Manual, Lux sensitivity- minimum 0.2 Lux at color, minimum 0.05 Lux at Black & White, 0.0 Lux (IR) Night Vision Distance Min IR- 150m, Power Supply : support 12/24 VDC, 24 VAC & PoE, IP67/IP66, IK10, built in micro SD/SDHC/SDXC card slot minimum 256 GB, built in microphone. (NCSR Rates Approved By SE Office Nagpur Vid. Letter No. 1919 Dt 04/12/2023) minimum Input/Output : Audio in × 1, Audio Out × 1, Alarm in× 1, Alarm Out × 1. Image Settings : Rotate mode, saturation, brightness, contrast, sharpness, gain, white balance. Image Enhancements : Day/Night-Auto (ICR)/Color/Black & White, 3D Digital Noise Reduction, Automatic White Balance, Automatic Gain Control, Backlight Compensation, Highlight Compensation.Events : Privacy Masking, Motion detection, Scene change detection, Face capture, Video tampering, audio exception detection, Region entrance detection, Region exiting detection. Operating temperature ( -30 to 60° C ) . Security : User account and password protection, HTTPS, IP filter, IEEE 802.1X, digest authentication, user access log, TLS1.2, AES-256, SSH/Telnet closed, FTP disabled. Protocol-DHCP, UDP, HTTP, HTTPS, NTP, DNS, RTP, RTSP, SMTP, SSL/TLS, TCP/IP, Secure Real-Time Transport Protocol (SRTP),Bonjour, SNMP and Secure shell (SSH) supported protocol. RoHS, WEEE, ISO-14001 and REACH compliant, UL/EN OR equivalent BIS/TECH/STQC or any indian standards as applicable, CE, FCC certified duly erected in position on wall/ceiling/false ceiling/provided pole (mounting height not more than 5 meter) etc with all accessories etc complete as per specification no CCTV-CAM. (NCSR Rates Approved By SE Office Nagpur Vid. Letter No. 1226 Dt 20/05/2024)

4

-

-

... More
Supplying, installing, testing & commissioning of 32/40 Ch. Network Video Recorder (NVR), suitable connect Min. 32 IP Cameras, up to 5 Megapixel Resolution, with HDMI/VGA outputs, provided HDMI output of 4K resolution or VGA output with output up to 1920 × 1080. Support H.265 or higher, H.264, MJPEG, Incoming Bandwidth 250Mbps with minimum 4 SATA Hard Disks, ANR Technology, 4 SATA interfaces for 4 HDDs and capacity of each HDD up to 8TB, minimum 02 USB port, Alarm I/O 16/4, RJ-45 10/100/ 1000 Mbps self-adaptive Ethernet interface, ONVIF conformance, Multiple network monitoring: Web viewer . support protocol TCP/IP, DHCP, DNS, DDNS, NTP, SADP, SMTP, NFS, iSCSI, UPnP™, HTTPS. RoHS, UL, CE, FCC certified duly erected in provided U Rack with wiring connections, tagging and programming etc. complete as per specification no. CCTV-NVR (NCSR Rates Approved By SE Office Nagpur Vid. Letter No. 1226 Dt 20/05/2024)

2

-

-

... More
Supplying & erecting 8 TB internal Surveillance HDD suitable for SATA Port of NVR, interface transfer rate 6 GB/S, maximum sustained transfer rate 210 MB/Sec to 213 MB/S. Drive bay supported 08+, Cameras supported up to 64, Cache (MB) 256, Load/Unload Cycle -3000000, Work Load Rating per Year 180TB, MTBF 1000000 Hrs. HTTPS. RoHS, UL, CE certified, duly erected in position in provided NVR as per specification no. CCTV-HDD (NCSR Rates Approved By SE Office Nagpur Vid. Letter No. 1226 Dt 20/05/2024)

10

-

-

... More
Supplying & erecting 43" professional LED display with 1920*1080 (Full HD) Display, suitable for 16/32 channel NVR and following features Brightness: minimum 500 Cd/m2 Contrast Ratio: minimum 1000:1 Viewing angle: 178/178 deg. Response time: maximum 8 ms Inputs: HDMI, VGA, BNC,USB, Audio In, Built-in speakers maximum 10 W, Suitable to operate on 100-240 V 50 Hz AC supply and 24/7 Duty Cycle duly erected on wall or table top with standard accessories like wall mount stand and wiring connections etc. complete as per specifications no. CCTV-MON (NCSR Rates Approved By SE Office Nagpur Vid. Letter No. 1226 Dt 20/05/2024)

2

-

-

... More
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with PVC accessories on wall /ceiling as per specification No: WG-MA/CON.

30

-

-

... More
Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW

10

-

-

... More
Supplying and erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW

10

-

-

... More
Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW

10

-

-

... More
Supplying and erecting mains with 1x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW

10

-

-

... More
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.

2

-

-

... More
Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete.

2

-

-

... More
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.

2

-

-

... More
Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.

2

-

-

... More
Supplying and erecting PVC Surface modular switch box with double mounting plate for 6 module duly erected.

2

-

-

... More
Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

3

-

-

... More
Supplying, erecting & marking DPMCB 40A to 63A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

3

-

-

... More
Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 4 ways/phase (12 poles), with door, 1.2mm thickness, surface/flush mounted, IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB

1

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

80

-

-

... More
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.

100

-

-

... More
Supplying and erecting minimum Three & above star rated submersible pump set of 3.75 KW/5 HP with 415 V, 50 c/s AC supply suitable for 150 mm dia. borewell suitable for 60 to 290 LPM discharge at 112 to 12 m head & discharge & delivery Pipe of Size-50mm diameter with a necessary H type clamps as per specification No. WP-SMP (Borewell Depth = 60Mtr)

1

-

-

... More
Supplying and erecting minimum Three & above star rated submersible pump set suitable for erection on open well of 2.25 KW/3 HP with 415 V 50 c/s. A.C. supply, having delivery head from 27 to 9 m and discharge from 300 to 660 litres. per minute & pipe of Suction 65mm /Delivery 50 mm diameter erected with necessary H type clamps as per specification No. WP-OSP

2

-

-

... More
Supplying & erecting flat flexible 3 core 4 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete.

120

-

-

... More
Supplying & erecting automatic control panel for 3 Phase , 415 volt, A.C, Submersible/centrifugal pump set up to 7.5 HP consisting of DOL starter having relay range 9-14 AMP,S.P.P., Combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc .

3

-

-

... More
Making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose).

0.3

-

-

... More
Supplying and erecting ISI mark GI pipe 50 mm dia.‘B’ class at position with accessories complete as per specification no. CW-PLB/GP.

80

-

-

... More
Supplying and erecting non return valve 50 mm dia in position made of gun metal complete.

3

-

-

... More
Supplying and erecting CI flange 50 mm. dia with necessary nuts bolts and washers with rubber seal in position complete.

8

-

-

... More
Supplying, erecting, testing & commissioning 11 kV, 630A, 21kA/3sec, 3 way outdoor, extensible motorised SCADA compatible RMU, internal arc tested consisting of 2 nos. feeder with 2 LBS and 1 no. feeder with 1 VCB. compliant to IEC 62271 -100, 200 and 102, as per specification no. SW-HTS/RMU SCADA

1

-

-

... More
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.

100

-

-

... More
Supplying, erecting, testing and commissioning 11KV HT metering cubical (compact / vertical type) approved by MSEDCL / licensee fabricated with 2 mm (14 SWG) M.S. sheets with supporting angle, painted with powder coating / epoxy paint of required shade, copper bus bar size 25 x 6 mm, heavy duty mechanical lock, with counter meter for measuring no of times the opening of meter door, top side cover (CT, PT cover) interlock with meter door, epoxy casted 3 nos. CT having required ratio between 50/5A to 200/5A, VA 10 or 15, Class 0.2S, epoxy casted 3 nos. PT having ratio 11000/V3/110/V3 VA 50, Class 0.2 suitable for provided trivector meter, and provision for incoming and outgoing cables complete duly tested by licensee with necessary test certificates and erected on provided plinth/ cc foundation.

1

-

-

... More
Supplying, installation, testing and commissioning extendable/non-extendable outdoor type 11 kV 630A, load break isolator switch, compliant to IEC 62271 -100, 200 and 102,on provided MS channels/trench/foundation as per specification no SW-HTS / LBS

1

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 300 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

300

-

-

... More
Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 11 kV(E), 3 x 300 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT

160

-

-

... More
Providing and erecting Heat shrinkable out door termination kit for 11 kV ( E ) XLPE HT cable 3x240 to 300 sq. mm. with necessary material as per specification no. CB-JT/HT

2

-

-

... More
Supplying & laying (including excavation) half round reinforced cement concrete pipe of IS 458:2003 NP-2 class of 250 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.

230

-

-

... More
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials, testing & recording the results as per specification no. EA-EP

3

-

-

... More
Supplying, installation and testing of maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete, and recording the results Specification no. EA-MOBI

6

-

-

... More
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.

210

-

-

... More
Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete.

130

-

-

... More
Providing and back filling ground enhancing compound 25 kg bag complete.

3

-

-

... More
Supplying, installing, testing & commissioning compact substation with 3 phase, 11/0.433 kV, 50 Hz., 500 kVA, Mineral Oil immersed Copper wound, without gas cushioning , hermetically Sealed transformer having indoor type transformer bushings, with HT side (incoming side) load break switch of appropriate capacity and LT side (outgoing side) MCCBs (4 pole) of appropriate capacity , with out inbuilt metering cubical, using type A winding insulation (kraft paper),standard accessories complete with test certificate with losses below 1510 Watts at 50% load, 4300 Watts at 100% load for transformer, as per IS:1180 (part 1) : 2014 , with necessary permissions of Electrical Inspectors per specification no SS- TR-SL. (Without Metering Cubical) [Base Rate -2185158-35000 = 2150158/-]

1

-

-

... More
Supplying and erecting 11 kV outdoor type gang operated air break, triple pole switch 400 A capacity with 3 post pin type insulator per phase, mounted in horizontal or vertical position with necessary channels on provided cross arm with adequate length of "C" class G.l. pipe for operating handle erected on extended square shaft. The operating handle provided with lock and key at suitable height from ground level with necessary clamp.

1

-

-

... More
Supplying & erecting barbed wire two ply with 12 SWG ply and 12 SWG barb with a gap between two bars of 75 mm. firmly fixed on provided angle supports with necessary materials complete. (6.044 meters/kg.).

60

-

-

... More
Providing pair of duly tested rubber hand gloves as per IS :47705 suitable for working up to 22 kV supply complete.

2

-

-

... More
Making trench in Hard murum/Tar road having 0.75 m depth and minimum 0.3mtr width as per IS for laying provided cables up to voltage level 1.1Kv cable complete as per specification No. CW-EXN-CTR

100

-

-

... More
Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete 20 x 25 mm stone metal, (45 x 45 x 45) cm /45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. (above 6 m to 9 m poles)

5

-

-

... More
Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete, (20 to 25) mm stone metal with necessary curing and finishing complete.(for stay).

2

-

-

... More
Making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose).

30

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.