Public Works Department Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Public Works Department - PWD Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date5 Oct 2024
Closing Date11 Oct 2024
Tender Amount₹ 22,48,83,627 
Notes
Download

Costs

Summary

Construction Of 60 Bedded Women Hospital Building At Majalgaon Tq.majalgaon Dist.beed

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Conveying materials obtained from road cutting including all lifts, laying in layers of 20 centi metre to 30 centi metre breaking clods, dressing to the required lines, curves, grades and section, watering and compacting to not less than 97% of standard Proctor density for a lead of over 50 metre to 300 metre inclusive from the site of excavation to the site of deposition as directed.

7530.12

-

-

... More
Providing preconstructional antitermite treatment as per Indian Standard 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper.

4142.82

-

-

... More
Providing preconstructional antitermite treatment as per Indian Standard 6313 (Part-II) treatment by treating the backfill in immediate contact with foundation at the rate of 5 litres of emulsion concentrate of 1.0 percent of clorophyrifos per square metre of vertical surface area covering 10 years guarantee on bond paper.

4010.51

-

-

... More
Providing preconstructional antitermite treatment as per Indian Standard 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per square metre of surface area covering ten years guarantee on bond paper.

1926.88

-

-

... More
Providing preconstructional antitermite treatment as per Indian Standard 6313 (Part-I) to the soil along the external face of building by punching holes of 1.2 of 1.5 Cement Mortor diametre about 30 -60 centi metre deep at 15 centi metre centre to centre as close to the wall as possible and to inject 0.5 percent of aldrin or clorophyrifos at the rate of 7.5 litres per hole and sealing the same with proper filling and covering 10 years guarantee on bond paper.

3050.92

-

-

... More
Providing soling using 80 mili metre size trap metal in 15 centi metre layer including filling voids with Crushed sand/grit, ramming, watering etcetera complete.

1874.43

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Crushed sand VSI Grade)

528

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-15 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etcetera complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etcetera (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Crushed sand VSI Grade)

528.73

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete M-15 of trap/ granite/quartzite/gneiss metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etcetera complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etcetera (Wooden centering will not be allowed.) With fine aggregate (Crushed sand VSI Grade)

-

-

-

... More
D] Terrace Floor

10.56

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite /quartzite/ gneiss metal for Reinforced Cement Concrete work in foundations like raft, strip foundations, grillage and footings of Reinforced Cement Concrete columns and steel stanchions etcetera columns as per detailed designs and drawing or as directed including Steel centering formwork, cover blocks laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etcetera complete. (Excluding reinforcement and structural steel) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Crushed sand VSI Grade)

2085.67

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite /quartzite/ gneiss metal for Reinforced Cement Concrete columns as per detailed designs and drawing or as directed including steel centering, formwork,cover blocks, laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etcetera complete,(Excluding reinforcement and structural steel) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Crushed sand VSI Grade)

-

-

-

... More
A] Ground Floor

167.79

-

-

... More
B] First Floor

109.38

-

-

... More
C] Second Floor

69.4

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite /quartzite/ gneiss metal for Reinforced Cement Concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/ pumping, compactionand roughening the surface if special finish is to be provided and curing etcetera complete. (Excluding reinforcement and structural steel) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Crushed sand VSI Grade)

-

-

-

... More
A] Ground Floor

494.74

-

-

... More
B] First Floor

236.19

-

-

... More
C] Second Floor

44.28

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap/ granite / quartzite/ gneiss metal for Reinforced Cement Concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etcetera complete,(Excluding reinforcement and structural steel) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Crushed sand VSI Grade)

-

-

-

... More
A] Ground Floor

397.72

-

-

... More
B] First Floor

415.17

-

-

... More
C] Second Floor

82.16

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/ pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Crushed sand VSI Grade)

-

-

-

... More
A] Ground Floor

2.58

-

-

... More
B] First Floor

1.13

-

-

... More
C] Second Floor

0.36

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite / quartzite / gneiss metal for Reinforced Cement Concrete canopy as per detailed designs and drawings including steel centering, formwork, laying/ pumping, compacting and roughening the surface if special finish is to be provided and curing etcetera complete (excluding reinforcement). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Crushed sand VSI Grade)

7.5

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete pardi of required thickness including steel centering, formwork, cover blocks, laying/ pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Crushed sand VSI Grade)

-

-

-

... More
A] Ground Floor

24.98

-

-

... More
B] First Floor

14.07

-

-

... More
C] Second Floor

20.92

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap / quartzite /granite /gneiss metal for Reinforced Cement Concrete Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/ pumping, compaction, finishing uneven and honeycombed surface with Cement Mortor 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etcetera complete. (Excluding reinforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etcetera) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Crushed sand VSI Grade)

-

-

-

... More
A] Ground Floor

18.45

-

-

... More
B] First Floor

18.45

-

-

... More
Providing and fixing in position Thermo Mechanical Treated (TMT) - FE - 500 bar reinforcement of various diameters for Reinforced Cement Concrete pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etcetera as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.

-

-

-

... More
A] Ground Floor

265.49

-

-

... More
B] First Floor

97.88

-

-

... More
C] Second Floor

29.1

-

-

... More
Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etcetera as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etcetera and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etcetera complete.

-

-

-

... More
C] Second Floor

0.36

-

-

... More
Providing fly ash brick masonry with conventional / Indian Standard type fly ash bricks in Cement Mortor 1:6 in foundation and plinth including bailing out water manually striking joints, racking out joints watering and scaffolding etcetera complete.

108.54

-

-

... More
Providing Autoclaved Aerated Concrete Block masonary of Ecolite or equivalent make conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in superstructure including striking joints, raking out joints and scaffolding etcetera Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972)

-

-

-

... More
A] Ground Floor

555.48

-

-

... More
B] First Floor

821.42

-

-

... More
C] Second Floor

245.15

-

-

... More
Providing Autoclaved Aerated Concrete Block masonary of Ecolite or equivalent make conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in Half brick thick wall including striking joints, raking out joints and scaffolding etcetera Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972)

-

-

-

... More
A] Ground Floor

6.61

-

-

... More
B] First Floor

6.65

-

-

... More
C] Second Floor

4.41

-

-

... More
Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in Cement Mortor1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with Cement Mortor1:3 admixed with approved water proofing compound and finally top finishing with average 20 mili metre. thick layers of same mortar added with jute fiber at 1 Kilogram per bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300 mili metre x 300 mili metre making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etcetera complete.

-

-

-

... More
A] Ground Floor

57.68

-

-

... More
B] First Floor

2298.1

-

-

... More
C] Second Floor

469.72

-

-

... More
Providing water proof bedding for flooring of Bath and Water Closet 25 mili metre thick in Cement Mortor 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etcetera complete.

-

-

-

... More
B] First Floor

106.25

-

-

... More
C] Second Floor

5.1

-

-

... More
Providing and applying two coats of High Albedo paint having minimum Solar Reflective Index (SRI) 108 (with solar reflectance & thermal emittance tested as per ASTM) C 1549 and ASTM C 1371 respectively, VOC less than 10 cc/gm. The coating thickness and the methodology of application shall strctly as per manufacturer's specifitions and as approved by engineer in charge. Surface preparation includes cleaning with metal wire brush to remove all dust, fungus etcetera washing with water all complete.The contractor shall give guarantee for the performance of SRI and also the durabitity of coating, all complete as per direction of Engineer - in- incharge.

-

-

-

... More
A] Ground Floor

57.68

-

-

... More
B] First Floor

2298.1

-

-

... More
C] Second Floor

469.72

-

-

... More
Providing and fixing 20 to 25 mili metre thick rough shahabad box type waterproofing for basement or underground floor on a base of Cement concrete 1:3:6, including sub base of 2.50 centimeter thick Cement mortar 1:3 with conceal, secrete (RMW), Algae proof or other alike waterproofing liquids, raking of joints upto 35 mili metre depth, filling the joints with 6 mili metre size crushed metal, hand grouting with cement slurry, curing and cleaning, with 7 years guarantee on court fee stamp of Rs. 100/- with ponding test etcetera complete. (excluding Cement concrete 1:3:6 base concrete )

99.53

-

-

... More
Providing and fixing 20 to 25 mili metre thick rough shahabad box type waterproofing treatment to vertical outside faces of Reinforced Cement concrete walls of basement or underground floor including filling the gap of 25 mili metre between rough shahabad and Reinforced Cement Concrete walls with cement grout mixed with water proofing liquid Algae proof or other alike with one tile lift method, brushing the joints horizontally with cement slurry mixed with water proofing liquid for width 30 to 35 mili metre and sloping coping over topmost tile with cement mortar 1:3, butting the bottom most with Cement concrete 1:2:4 mixed with water proofing liquid, curing, with 7 years guarantee on court fee stamp of Rs.100/- with ponding test etcetera complete. (excluding Cement concrete 1:3:6 base concrete)

95.57

-

-

... More
Providing and applying plaster / wall punning with plaster of paris ( with plaster of paris material of Ambuja / Mor Chap or equivalent make ) in 10 to 13 mili metre thickness to previously plastered surface / or on newly brick surface (Excluding rough cast plaster) in all position including preparing and Finishing the surface scaffolding etcetera complete.

-

-

-

... More
A] Ground Floor

3824.62

-

-

... More
B] First Floor

3310.71

-

-

... More
C] Second Floor

606.22

-

-

... More
Providing internal cement plaster 20 mili metre thick in single coats in cement mortar 1:5 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etcetera complete

186.97

-

-

... More
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mili metre thick in cement mortar 1:4 using waterproofing compound at 1 Kilogram per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mili metre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etcetera complete.

-

-

-

... More
A] Ground Floor

1881.19

-

-

... More
B] First Floor

1454.45

-

-

... More
C] Second Floor

1786.51

-

-

... More
Providing and applying Texture plaster with finishing with texture material of approved make in 3 to 4 mili metre thickness on previously plastered surface, including Plaster Groove 6 mili metre thickness or Tape Grooves 35 to 45 mili metre thickness or as required, in all position including preparing the surface, scaffolding etcetera complete.

-

-

-

... More
A] Ground Floor

365.68

-

-

... More
B] First Floor

290.89

-

-

... More
C] Second Floor

357.3

-

-

... More
Providing fine cement finish 1.5 mili metre thick over green plaster surface including scaffolding curing etcetera complete.

709.02

-

-

... More
Providing patti/ band 75 mili metre wide on plastered surface 12 mili metre to 15 mili metre thick in Cement Mortor 1:3 line and level including neat finishing scaffolding curing etcetera complete.

-

-

-

... More
A] Ground Floor

300

-

-

... More
B] First Floor

300

-

-

... More
C] Second Floor

50

-

-

... More
Providing patti/ band 100 mili metre wide on plastered surface 12 mili metre to 15 mili metre thick in Cement Mortor 1:3 line and level including neat finishing scaffolding curing etcetera complete.

-

-

-

... More
A] Ground Floor

300

-

-

... More
B] First Floor

300

-

-

... More
C] Second Floor

50

-

-

... More
Providing patti/ band 150 mili metre wide on plastered surface 12 mili metre to 15 mili metre thick in Cement Mortor 1:3 line and level including neat finishing scaffolding curing etcetera complete.

-

-

-

... More
A] Ground Floor

300

-

-

... More
B] First Floor

300

-

-

... More
C] Second Floor

50

-

-

... More
Providing and fixing chicken mesh of 22 gauge, with about 30 centi metre width at the junction of Reinforced Cement Concrete members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /Burnt Brick Masonry and or tying by binding wire etcetera complete.

-

-

-

... More
A] Ground Floor

1037.16

-

-

... More
B] First Floor

936.03

-

-

... More
C] Second Floor

518.41

-

-

... More
Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etcetera complete.

-

-

-

... More
A] Ground Floor

521.74

-

-

... More
B] First Floor

752.89

-

-

... More
C] Second Floor

199.02

-

-

... More
Providing and fixing Modular false ceiling of 600 x 600 mili metre center to center and 13 mili metre thick square mineral fiber board to be fixed on frame work of alluminium sections for suspended false ceiling consisting of alluminium T 2”x1 ½” (50 mili metre x 40 mili metre) weighing 0.39 Kilogram/ metre at 60 centi metre center center and fixed with ½” x ½” (15 x 15 mili metre) flanges weighing 0.19 Kilogram/ metre suspended on 6 mili metre diametre mild steel rod weighing 0.22 Kilogram/ metre, fixed on wall and beams including rounding of the edges with alluinium T of 2” x 1 ½” (50 mili metre x 40 mili metre) weighing 0.39 Kilogram/ metre etcetera (all alluminium sections shall be anodized) including all labour, material, lifts etcetera complete.

-

-

-

... More
A] Ground Floor

1919.13

-

-

... More
B] First Floor

1603.04

-

-

... More
C] Second Floor

150.63

-

-

... More
Providing groove to required size at specified location as directed by Engineer, at junction of brick masonry wall and Reinforced Cement Concrete beams or Column, at junction of composite masonry, including scaffolding, finishing, curing etcetera complete.

-

-

-

... More
A] Ground Floor

300

-

-

... More
B] First Floor

300

-

-

... More
C] Second Floor

50

-

-

... More
Providing and laying vitrified matt fininsh tiles having size 590 mili metre to 605 mili metre x to 605 mili metre of 8 to 10 mili metre thickness and confirming Indian Standard 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etcetera complete.

-

-

-

... More
A] Ground Floor

2268.82

-

-

... More
B] First Floor

2207.75

-

-

... More
C] Second Floor

194.61

-

-

... More
Providing and laying vitrified matt finish tiles having size 590 mili metre to 605 mili metre x to 605 mili metre of 8 to 10 mili metre thickness and confirming Indian Standard 15622-2006 (Group Bla) of approved make, shade and pattern for dado & skirting in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etcetera complete.

-

-

-

... More
A] Ground Floor

1676.64

-

-

... More
B] First Floor

1475.55

-

-

... More
C] Second Floor

274.99

-

-

... More
Providing and fixing heavy duty inter locking concrete Coloured paving blocks of 80 mili metre thickness of having a strength of 300 Kilogram/Square Centi Metre of approved quality and shape on a bed of crushed sand of 25 to 30 mili metre thick including skirting joints and cleaning etcetera complete

3050.92

-

-

... More
Providing and laying ceramic tiles having size 30 centi metre x 60 centi metre confirming to corresponding Indian Standard for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etcetera complete.

-

-

-

... More
A] Ground Floor

352.9

-

-

... More
B] First Floor

355.28

-

-

... More
C] Second Floor

87.91

-

-

... More
Providing and laying Antiskid Ceramic tiles of approved quality of size 30 centi metre x 30 centi metre and Confirming to Indian Standard 15622-2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etcetera complete.

-

-

-

... More
A] Ground Floor

128.75

-

-

... More
B] First Floor

148.18

-

-

... More
C] Second Floor

36.68

-

-

... More
Providing and laying machine cut machine Polished Kota stone flooring 25 mili metre to 30 mili metre thick and required width in plain/ diamond pattern on bed of 1:6 Cement Mortor including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etcetera complete.

-

-

-

... More
A] Ground Floor

8.97

-

-

... More
C] Second Floor

98.98

-

-

... More
Providing Mirror polishing to Kota Stone including using all necessary stones and equipments cleaning, washing etcetera complete. For Flooring

-

-

-

... More
A] Ground Floor

8.97

-

-

... More
C] Second Floor

98.98

-

-

... More
Providing and laying machine cut machine polished machine cut Kota stone slabs 20 to 25 mili metre thick for treads and risers of steps and staircases, with rounded nosing for the treads on a bed of 1:4 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etcetera complete.

-

-

-

... More
C] Second Floor

4.8

-

-

... More
Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mili metre to 20 mili metre thick on bed 1:6 cement mortar including cement floats striking joints, pointing in Cement Mortor 1:3 curing and cleaning etcetera complete.

72.65

-

-

... More
Providing and fixing machine cut machine polished 18 mili metre to 20 mili metre thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etcetera complete.

-

-

-

... More
A] Ground Floor

103.32

-

-

... More
B] First Floor

85.8

-

-

... More
C] Second Floor

85.8

-

-

... More
Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mili metre thick for door frame/ dado/ window boxing etcetera On Cement Mortor 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etcetera complete.

-

-

-

... More
A] Ground Floor

223.97

-

-

... More
B] First Floor

223.72

-

-

... More
C] Second Floor

36.52

-

-

... More
Providing and laying chequered tiles of approved quality of size 30 centi metre x 30 centi metre, confirming to corresponding Indian Standard for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etcetera complete.

-

-

-

... More
A] Ground Floor

66.93

-

-

... More
B] First Floor

66.93

-

-

... More
Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 mili metre x 450 mili metre size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 mili metre thick supports with kadappah top 35 to 40 mili metre thick and polished granite 16 to 20 mili metre top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 centi metre height and top granite of 75 x 40 centi metre including cutting, opening for sink of required size in kadappah as well as granite etcetera complete. (Platform top size 5.00 metre x 0.60 metre and height is 0.75 m)

-

-

-

... More
C] Second Floor

2.85

-

-

... More
Kitchen Trolley Providing and Fixing stainless steel kitchen trolley of overall 26 " height and 22" depth,supported on aluminium pipes ,trolley basket made out of 5 mili Mild Steeltainless steel rod fitted on telescopic channel of size 1.5 " x 20 " x 22 " on both sides of trolley of 12 " or above size, panel having 40 Kilogram load bearing capacity of trolley made out of 20 mili metrePUC coated plywood and colour combination as directed by E-I-C.Inner side of panel covered by white mica ,100 mili Mild Steels. decorative handle.(The width and height of individual compartments shall be kept as directed by Engineer-in-charge)

-

-

-

... More
C] Second Floor

3.8

-

-

... More
Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etcetera complete.

-

-

-

... More
A] Ground Floor

512.74

-

-

... More
B] First Floor

752.89

-

-

... More
C] Second Floor

199.02

-

-

... More
Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces. (excluding the primer coat.) etcetera complete.

-

-

-

... More
A] Ground Floor

512.74

-

-

... More
B] First Floor

752.89

-

-

... More
C] Second Floor

199.02

-

-

... More
Providing and applying 2 coats of 100% Pure acrylic low VOC and APEO & HCHO free water based paint of approved colour that belongs to class 1 flame spread resistance of approved make Paint should provide durable and long lasting silk finish with a high crack tolerance of upto 1 mili metre Paint should have an oustanding washability with high resistance to wide range of bacteria and fungus. Paint has to be applied on smooth and uniform surface prepared by an acrylic copolymer low VOC & Odour putty. This surface should be primed with water based low VOC Primer. The work activity should cover all aspects of applying paints from surface preparation as directed by Engineer in charge.

-

-

-

... More
A] Ground Floor

3824.62

-

-

... More
B] First Floor

3310.71

-

-

... More
C] Second Floor

606.22

-

-

... More
Providing and applying 2 Coats of 100% Pure acrylic water based paint with special heat reflectance property to withstand the harsh climate for period of atleast 10 years of approved make. Paint system should provide durable and long lasting finish with DFT of min 90 microns and should protect against concrete carbonation with R value of minimum 600 and equivalent concrete layer thickness value of min 150 centi metre Paint should have breathability property and should be able to cover hairline cracks in the surface upto 0.5 mili metre The paint has to be applied on a coat of high quality acrylic copolymer based alkali resistant primer with excellent penetrating properties including cleaning, with all leads and lifts at all levels etcetera complete, as directed by Engineer in charge.

-

-

-

... More
A] Ground Floor

1462.74

-

-

... More
B] First Floor

1163.56

-

-

... More
C] Second Floor

1429.21

-

-

... More
Providing and applying Dezzly texture paint of Hammer / Screetech on the external plastered surface of approved quality. As directed by Engineer in charge

-

-

-

... More
A] Ground Floor

182.84

-

-

... More
B] First Floor

145.45

-

-

... More
C] Second Floor

178.65

-

-

... More
Providing and applying two coats Apex Ultima Puranature Anti-Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC’s, CO, SOx, formaldehydes, etcetera) in presence of natural or artificial light. It contains Graphene and nanoparticles of titanium oxide. and Absorbs CO2 (4.8 Kilogram/15 l). plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recommended applicator and he should be able to furnish stage wise onsite technical reports from the concerned company technologist.

-

-

-

... More
A] Ground Floor

182.84

-

-

... More
B] First Floor

145.45

-

-

... More
C] Second Floor

178.65

-

-

... More
Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300 mili metre x 40 mili metre x 5 mili metre with oil painting, etcetera complete

0.33

-

-

... More
Providing and fixing Country cut teak wood double or single leaf panelled shutters, 35 mili metre thick style top and freze rail 95 x 35 thick with lock and bottam rail 195 x 25 mili metre thick and panels without ventilator as per detailed drawing excluding the door frame, stainless steel fixtures and fastening and finishing the wood work with oil painting 3 coats complete

14.4

-

-

... More
Providing and fixing 34 mili metre thick moulded door shutter consisting of solid core single leaf flush door of 30 mili metre thickness lipped with 15 mili metre( 5 mili metre x 3) thick x 30 mili metre width on one style and top rail and 10 mili metre(5 mili metre x 2) thick x 30 mili metre width on other style and bottom rails. The inner panels laminated with 2 mili metre thick termite proof, water proof and fire resistant moulded Polyvenyle Chloride sheet with 2,4,6 design in different plain and /or prelim colours on one side after routing the moulded design on flush doors and 2 mili metreplain and /or pre lam Polyvenyle Chloride on other side using rubber adhesive on flush door and solvent cement adhesive on the Polyvenyle Chloride lipping etcetera as per direction of Engineer in charge and manufacturers specification and drawing etcetera complete.

-

-

-

... More
A] Ground Floor

97.41

-

-

... More
B] First Floor

83.48

-

-

... More
C] Second Floor

20.2

-

-

... More
Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 mili metre x 1.22 mili metre box type, 5 mili metre thick sheet glass louvers, of approved quality etcetera complete.

-

-

-

... More
A] Ground Floor

8.1

-

-

... More
B] First Floor

8.1

-

-

... More
C] Second Floor

0.54

-

-

... More
Providing and Fixing 30 mili metre thick BOTH SIDE PRELAMINATED SOLID PANEL Polyvenyle Chloride DOOR SHUTTER consisting of frame made out of Mild Steel tubes of 19 guage thickness and, size 19 x 19 mili metre for styles and 15 x15 mili metre for the top and bottom rails, Mild Steel frame shall have a coat of metel primer of approved make and manufacture. Mild Steel frame shall be covered with heat mouled Polyvenyle Chloride 'C' channel made from 5 mili metre(+/0.25) thick prelaminated sheet of density 600 Kilogram/cbm ,of size 30 mili metre thickness 70 mili metre width out of which 50 mili metre shall be flat and 20 mili metre shall be tapered in 45 angle on either side forming stiles ; and 5 mili metre thick ,95 mili metre wide Polyvenyle Chloride sheet out of which 75 mili metre shall be falt and 20 mili metre shall be tapered in 45 on the inner side to form top and bottom rail and 115 mili metre wide Polyvenyle Chloride sheet out of which 75 mili metre shall be falt and 20 mili metre shall be tapered on both sides to form lock rail.Top,bottom and lock rail shall be provided either side of the panel. An additional 5 mili metre(+/0.25) thick Polyvenyle Chloride strip of 20 mili metre width is to be stuck on the bottom side of the ' c ' channel prelaminated paneling of 5 mili metre(+/0.25) thick Polyvenyle Chloride sheet to be fitted inside the Mild Steel frame welded/ sealed to the styles and rails with 5 mili metre(+/0.25) x 30 mili metrePolyvenyle Chloride sheet beading on either side and joined together with solvent cement adhesive etcetera ,10 mili metre thickness (5 mili metre(+/0.25) x 2 nos ) 20 mili metre wide cross Polyvenyle Chloride sheet as gap insert for the rail and bottom rail. Door to be fixed to frames with 3 nos Mild Steelpowder coated but hinges of size 100 mili metre x 25 mili metre x 2 mili metre using 32 mili metre long steel screws drilled suitable to pass through both the walls of the Mild Steel tube. Other hardwares should be fixed with 19 x 6 mili metre size steel screws including fixture fasting. Complete as per direction of engineer in charge .

-

-

-

... More
A] Ground Floor

40.95

-

-

... More
B] First Floor

37.8

-

-

... More
C] Second Floor

3.15

-

-

... More
Providing and fixing in position. (as per Indian Standard 1868 / 1982) Aluminium sliding window of two tracks with rectangular pipe having overall dimension 63.50 x 38.10 x 1.02 mili metre at weight 0.547 Kilogram/Running Metre and window frame bottom track section 61.85 x 31.75 x 1.20 mili metre at weight 0.695 Kilogram/Running Metre Top and side track section 61.85 x 31.75 x 1.30 mili metre at weight 0.659 Kilogram/Running Metre The shutter should be of bearing bottom 40 x 18 x 1.25 mili metre at weight 0.417 Kilogram/Running Metre Inter locking section 40 x 18 x 1.10 mili metre at weight 0.469 Kilogram/Running Metre And handle section 40 x 18 x 1.25 mili metre at weight 0.417 Kilogram/Running Metre and top section 40 x 18 x 1.25 mili metre at weight 0.417 Kilogram/Running Metre As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mili metre thick plain glass with all required screws and nuts etcetera complete. With powder coating without box

-

-

-

... More
A] Ground Floor

19.5

-

-

... More
B] First Floor

15

-

-

... More
C] Second Floor

3

-

-

... More
Providing and fixing in position (as per 1868 / 1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mili metre at weight 0.637 Kilogram/Running Metre with window frame bottom track section 92 x 31.75 x 1.30 mili metre at weight 1.070 Kilogram/Running metre Top and side track section 92 x 31.75 x 1.30 mili metre at weight 0.933 Kilogram/Running Metre The shutter should be of bearing bottom 40 x 18 x 1.25 mili metre at weight 0.417 Kilogram/Running Metre Inter locking section 40 x 18 x 1.10 mili metre at weight 0.469 Kilogram/Running Metre and handle and top section 40 x 18 x 1.25 mili metre at weight o.417 Kilogram/Running Metre As per detailed drawings and as directed by Engineer-in-charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mili metre thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etcetera complete. With powder coating without box

-

-

-

... More
A] Ground Floor

48.6

-

-

... More
B] First Floor

22.5

-

-

... More
C] Second Floor

9

-

-

... More
Supplying and fixing in position Powder Coated Aluminium four track sliding windows with outer frame made from section of over all size 122 mili metre x 45 mili metre, bottom section with drain section track weighing 1.83 Kilogram per metre and top and side section of size 122x 31.75 mili metre weighing 1.15 Kilogram per running metre with shutter sections made of 18 mili metre x 40 mili metre size having average weight of 0.6 Kilogram per running metre (or as required size) with change in proportionate weight, with 6 mili metrefloat glass in three equal panels and alluminium coated stainless steel mosquito net in one (2/3 of opening) panel fixed with new neoprene gasket, shutters to be provided with nylon encased stainless steel rollers, necessary locks and handles complete. b) Powder Coated

-

-

-

... More
A] Ground Floor

87

-

-

... More
B] First Floor

153

-

-

... More
C] Second Floor

18

-

-

... More
Providing and fixing M-40 grade thick vibrated pull cast or similar type concrete frame with chamfer conforming to Indian Standard 6524-1983 having 6 mili metre diametre bars 3 Numbers And stirrups @250 mili metre centre to centre and fixing in wall with 6 Nos of hold fast of 12 mili metre diametre bars 500 mili metre long including primer and oil painting etcetera complete) frame size 60 mili metre x 100 mili metre

-

-

-

... More
D] Terrace Floor

30.6

-

-

... More
Providing and fixing aluminium grill diamond mesh type DG202 of 7.5 mili metre thick including fixing in position anodised aluminium frame section of 80 x 38 mili metre x 1.22 mili metre size box, cutting to the required size with all wastage, labour, lead lift etcetera complete.

-

-

-

... More
A] Ground Floor

151.5

-

-

... More
B] First Floor

190.5

-

-

... More
C] Second Floor

30

-

-

... More
Providing and Fixing mat finish stainless steel (of 302 grade ) railing with top pipe of 50 mili metre diametre and vertical pipe of 38 mili metre diametre at 0.60 metre centre to centre or as required and horizontal pipes of 25 mili metre diametre in three rows, all pipes of 2 mili metre thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 mili metre diametre above newel post of 75 mili metre diametre etcetera complete (Prior approval of sample and brand by Executive Engineer is necessary before use)

-

-

-

... More
A] Ground Floor

141.9

-

-

... More
B] First Floor

56.74

-

-

... More
Providing and fixing C.P. 2 Way BIB cock with wall flange of approved make including necessary sockets/ union nut etcetera complete as directed by Engineer in charge.

-

-

-

... More
A] Ground Floor

7

-

-

... More
B] First Floor

5

-

-

... More
Providing and fixing 25 mili metre diameter water meter with non-return valve including strainer, sockets/ union nut and including water meter box making locking arrangement and lock. [Without chamber].

1

-

-

... More
Providing and fixing 15 mili metre diametre screw down bib/ stop tap of brass including necessary socket union nut complete.

-

-

-

... More
A] Ground Floor

28

-

-

... More
B] First Floor

30

-

-

... More
C] Second Floor

2

-

-

... More
Providing and fixing 20 mili metre diametre screw down bib/ stop tap of brass including necessary socket union nut complete.

-

-

-

... More
A] Ground Floor

7

-

-

... More
B] First Floor

5

-

-

... More
Providing and fixing screw down 15 mili metre diametre wheeled stop tap of brass including necessary sockets/union nut complete

-

-

-

... More
A] Ground Floor

28

-

-

... More
B] First Floor

30

-

-

... More
C] Second Floor

2

-

-

... More
Providing and fixing push cock (Self closing tap) symet type of 15 mili metre diametre including necessary socket, testing etcetera complete.

-

-

-

... More
A] Ground Floor

41

-

-

... More
B] First Floor

42

-

-

... More
C] Second Floor

2

-

-

... More
Providing and fixing White glazed with bottle trap earthenware Wash Hand Basin of 63x45 centi metre size including cold water piller taps, brackets, rubber plugs and brass chain, stop tap, chromium plate bottle trap and necessary pipe connections including UPAC waste pipe and trap upto the outside face of the wall, making good the damaged surface, testing etcetera complete.

-

-

-

... More
A] Ground Floor

14

-

-

... More
B] First Floor

12

-

-

... More
C] Second Floor

2

-

-

... More
Providing and fixing Oval Type Under Counter Wash Hand Basin of 420 x 590 x 195 mili metre size with pillar cock, C.P.Angular stop cock, long thread of approved make continental including SS bottle trap of necessary pipe connection up to the outside face of the wall, having Telephonic Black / Colour Granite of 180 mili metre thick fixed on Black Kadappa Framework, etcetera Complete as directed by Engineer in charge.

-

-

-

... More
A] Ground Floor

13

-

-

... More
B] First Floor

15

-

-

... More
Providing and fixing 15 centi metre x 10 centi metre salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap.

-

-

-

... More
A] Ground Floor

41

-

-

... More
B] First Floor

42

-

-

... More
C] Second Floor

2

-

-

... More
Providing and laying concrete pipes of Indian Standard NP. class of 150 mili metre diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.

200

-

-

... More
Providing and laying concrete pipes of Indian Standard NP. class of 300 mili metre diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.

150

-

-

... More
Providing, constructing and fixing 250 mili metre diametre Inspection chamber made up of Unplastisized Polyvenyle Chloride material of thickness 3.5 mili metre and height of 259 mili metre with inlet and outlet of 110 mili metre diametre with 75 mili metre diametre U Trap, Ultra shaft pipe of Unplastisized Polyvenyle Chloride material having height of 470 mili metre and fixing Ultra 250 mili metre diametre Unplastisized Polyvenyle Chloride cover and frame in 150 mili metre thick in Cement Concrete1:2:4, having crushed sand bed of 100 mili metre thick of size 550 mili metre diametre Including excavation and refilling the sides of chamber by crushed sand cushioning 150 mili metre thickness, connecting all required Unplastisized Polyvenyle Chloride fittings with rubber lubricant etcetera complete.

20

-

-

... More
Providing, constructing and fixing 450 mili metre diametre Inspection chamber made up of Polypropylene / polyethylene material of thickness 3.5 mili metre and height of 388 mili metre with 160 or 200 mili metreain inlet (s) outlet and 110 and / or 160 mili metrebranch inlets, with 450 mili metre diametre Ultra shaft pipe of HDPE material having height of 460 mm, having Reinforced Cement Concrete cover and frame fixing in 150 mili metre thick in Cement Concrete1:2:4, having crushed sand bed of 150 mili metre thick of size 750 mili metre diametre Including excavation and refilling the sides of chamber by sand crushed cushioning 150 mili metre thickness, connecting all required Unplastisized Polyvenyle Chloride fittings with rubber lubricant etcetera complete.

10

-

-

... More
Providing and fixing 450 mili metre x 550 mili metre size superior type Belgium mirror with 16 mili metre diametre nickel plated towel rod etcetera complete.

-

-

-

... More
A] Ground Floor

34

-

-

... More
B] First Floor

32

-

-

... More
C] Second Floor

2

-

-

... More
Providing and fixing chromium plated towel rod 16 mili metre diametre and 75 centi metre in length including all accessories complete.

-

-

-

... More
A] Ground Floor

9

-

-

... More
B] First Floor

11

-

-

... More
Providing and fixing stainless steel sink of size 600 x 510 x 200 mili metre incluidng coupling, outlet pipe, elbow and other necessary fitting, finishing etcetera complete.

-

-

-

... More
C] Second Floor

1

-

-

... More
Providing and fixing C.P. Angular stop clock with wall flange of approved make continental including necessary sockets/union nut etcetera complete.

-

-

-

... More
A] Ground Floor

7

-

-

... More
B] First Floor

5

-

-

... More
Providing and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etcetera complete.

-

-

-

... More
A] Ground Floor

7

-

-

... More
B] First Floor

5

-

-

... More
Providing and fixing C.P. sink cock with raised J" shaped swinging casted spout ofapproved make including necessary sockets/ union nut etcetera complete."

-

-

-

... More
C] Second Floor

1

-

-

... More
Providing and fixing 40 mili metre diametre Ball cock medium type with Polyvenyle Chloride float including sockets and necessary fittings and tested as per municipal requirements etcetera complete.

-

-

-

... More
C] Second Floor

10

-

-

... More
Providing and fixing 15 mili metre diametre Ball cock medium type with Polyvenyle Chloride float including sockets and necessary fittings and tested as per municipal requirement etcetera complete.

-

-

-

... More
C] Second Floor

10

-

-

... More
Providing and fixing wall mixer with over head shower, shower arm, hand shower with wall bracket having flow rate upto 12 liters/minutes of Jaquar/Cera/Hindware/Perryware or equivalent make including all necessary pipes, fittings etc. complete as directed by Engineer In Charge. (Make shall conform to manufacturer's Green product and shall got approved from the Engineer In Charge.)

-

-

-

... More
A] Ground Floor

9

-

-

... More
B] First Floor

11

-

-

... More
Providing and fixing C.P. wall mixer with provision for overhead shower with 115 mili metre long bend pipe and wall flange of approved make including necessary sockets/union nut etcetera complete.

-

-

-

... More
A] Ground Floor

9

-

-

... More
B] First Floor

11

-

-

... More
Providing and fixing Orissa Pan of size 580x445x260 mili metre with approved make flush valve including trap, Cast Iron soil and vent pipe upto outside face of wall including 100 mili metre diametre Cast Iron plug, bend and necessary pipe connection, etcetera complete. As directed by Engineer in charge.

-

-

-

... More
A] Ground Floor

5

-

-

... More
B] First Floor

6

-

-

... More
C] Second Floor

2

-

-

... More
Providing and fixing white Opal series European type wall-hung, of size 400 mili metrex370mmx575 mili metre with approved make flush valve including soil pipe, vent pipe upto outside face of wall, 100 mili metre diametre Cast Iron plug bend inlet pipe all fittings, cutting & making good walls, floors etcetera as directed by Engineer in charge.

-

-

-

... More
A] Ground Floor

21

-

-

... More
B] First Floor

18

-

-

... More
Providing and fixing white glazed earthenware lipped flat back/corner type Urinal with Polyvenyle Chloride 5 liters flushing cistern with fittings, inlet pipe with stop tap, brackets for fixing the cistern, 32 mili metre diametre Polyvenyle Chloride flush pipe with fitting including lead soil pipe, lead trap and soil pipe connection up to the outside face of wall.

-

-

-

... More
A] Ground Floor

13

-

-

... More
B] First Floor

12

-

-

... More
Providing and fixing 75 mili metre diametre stabiliser pipe/ Poly Venyle Chloride soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etcetera complete

-

-

-

... More
A] Ground Floor

250

-

-

... More
B] First Floor

250

-

-

... More
C] Second Floor

30

-

-

... More
Providing and fixing 100 mili metre diametre stabiliser pipe/ Poly Venyle Chloride soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etcetera complete.

-

-

-

... More
A] Ground Floor

250

-

-

... More
B] First Floor

250

-

-

... More
C] Second Floor

20

-

-

... More
Providing, laying and fixing ,jointing Eco- drain 110 mili metre SN 8 Nu- Drain Unplastisized Polyvenyle Chloride pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per Indian Standard15328 with fittings such a bends, tees, coupler, etcetera jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated material etcetera complete.

200

-

-

... More
Providing, laying and fixing ,jointing Eco- drain 160 mili metre SN 4 Nu- Drain Unplastisized Polyvenyle Chloride pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per Indian Standard15328 with fittings such a bends, tees, coupler, etcetera jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated materialetcetera complete.

150

-

-

... More
Providing and fixing H.D.P container Syntex or alike one piece moulded water tank made out of low density polythyler and built corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity above 1000 to 20,000 litres

-

-

-

... More
C] Second Floor

20000

-

-

... More
Providing and fixing on walls/ ceiling/ floor 15 mili metre diametre CPolyvenyle Chloride pipe with necessary fittings, remaking good the demolished portion etcetera complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etcetera complete.

-

-

-

... More
A] Ground Floor

200

-

-

... More
B] First Floor

200

-

-

... More
C] Second Floor

30

-

-

... More
Providing and fixing on walls/ceiling/floor 20 mili metre diametre CPolyvenyle Chloride pipe with necessary fittings, remaking good the demolished portion etcetera complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etcetera complete.

-

-

-

... More
A] Ground Floor

200

-

-

... More
B] First Floor

200

-

-

... More
C] Second Floor

30

-

-

... More
Providing and fixing on walls/ ceiling/ floor 25 mili metre diametre CPolyvenyle Chloride pipe with necessary fittings, remaking good the demolished portion etcetera complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etcetera complete.

-

-

-

... More
A] Ground Floor

150

-

-

... More
B] First Floor

150

-

-

... More
C] Second Floor

20

-

-

... More
Providing and fixing on walls/ ceiling/ floor 32 mili metre diametre CPolyvenyle Chloride pipe with necessary fittings, remaking good the demolished portion etcetera complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etcetera complete.

-

-

-

... More
A] Ground Floor

150

-

-

... More
B] First Floor

150

-

-

... More
C] Second Floor

20

-

-

... More
Providing and fixing on walls /ceiling/ floor 40 mili metre diametre CPolyvenyle Chloride pipe with necessary fittings, remaking good the demolished portion etcetera complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etcetera complete.

-

-

-

... More
A] Ground Floor

100

-

-

... More
B] First Floor

100

-

-

... More
C] Second Floor

10

-

-

... More
Providing and fixing on walls/ ceiling/ floor 50 mili metre diametre CPolyvenyle Chloride pipe with necessary fittings, remaking good the demolished portion etcetera complete.

-

-

-

... More
A] Ground Floor

100

-

-

... More
B] First Floor

100

-

-

... More
C] Second Floor

10

-

-

... More
Providing and fixing 15 centi metre rigid Polyvenyle Chloride Nahani trap including Polyvenyle Chloride grating ,bend,connectingpiece of Unplastisized Polyvenyle Chloride pipe up to the outside face of wall ,making the good damaged surface and testing etcetera complete ( Prior approval of sample and brand by Ex. Engr. is necessary before use)

-

-

-

... More
A] Ground Floor

68

-

-

... More
B] First Floor

69

-

-

... More
C] Second Floor

4

-

-

... More
Providing and fixing Poly Venyle Chloride Rain water pipes of 160 mili metre outer diameter and having wall thickness of 2.2 to 2.7 mili metreconfirming to Indian Standard 13592-1992 including proper rainwater receiving recess with Poly Venyle Chloride plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25 mili metre to 40 mili metre from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on Cement Concrete or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the Poly Venyle Chloride fittings and additional 2 piece socket clips shall be got approved from engineer in charge etcetera complete.

-

-

-

... More
A] Ground Floor

100

-

-

... More
B] First Floor

100

-

-

... More
C] Second Floor

20

-

-

... More
Providing and laying in trenches 15 mili metredai. CPolyvenyle Chloride pipe including necessary excavation, fittings. Refilling trenches etcetera complete Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etcetera complete.

200

-

-

... More
Providing and laying in trenches 20 mili metredai. CPolyvenyle Chloride pipe including necessary excavation, fittings. Refilling trenches etcetera complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etcetera complete.

200

-

-

... More
Providing and laying in trenches 25 mili metredai. CPolyvenyle Chloride pipe including necessary excavation, fittings. Refilling trenches etcetera complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etcetera complete.

150

-

-

... More
Providing and laying in trenches 32 mili metredai. CPolyvenyle Chloride pipe including necessary excavation, fittings. Refilling trenches etcetera complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etcetera complete.

150

-

-

... More
Providing and laying in trenches 40 mili metre dai. CPolyvenyle Chloride pipe including necessary excavation, fittings. Refilling trenches etcetera complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etcetera complete.

100

-

-

... More
Providing and laying in trenches 50 mili metre dai. CPolyvenyle Chloride pipe including necessary excavation, fittings. Refilling trenches etcetera complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etcetera complete.

100

-

-

... More
Providing and fixing in position Unplastisized Polyvenyle Chloride ultra violet stabilized 110 mili metre outer diameter cowl dome confirming to Indian Standard-4985 including making joints with solvent cement etcetera complete

-

-

-

... More
B] First Floor

22

-

-

... More
C] Second Floor

2

-

-

... More
Providing and fixing Glass self 125 mili metre wide and 600 mili metre long with necessary chromium plated brackets providing Teak Wood gutties etcetera complete

-

-

-

... More
A] Ground Floor

7

-

-

... More
B] First Floor

5

-

-

... More
Providing & Supplying corrosion inhibiting admixture in concrete to protect steel bars for all concrete in every part Polyalk CP 293 of approved make & approved by Engineer in charge migrating, non-nitrite based corrosion inhibiting admixture shall be added at a dose of 3 Kilograms per Cubic Metre of concrete. The admixture should protect both cathodic and anodic sites and have been accredited by Indian Roads Congress, recommended for use by Ministry of Road Transport & Highways and should have a 4 year track record of use in both the Gulf Region and Indiametre Admixture should have evaluated test reports demonstrating a corrosion rate of zero coulombs after 9 test cycles as per ASTM G 109 when tested from a research institution NBA accredited Grade A and internationally ranked among top 5 research institutions in the world in Annual Survey conducted by Georgia Institute of Technology ranking of research institutions. PH of admixture should be alkaline in nature, specific gravity of 0.99 – 1.1, colour : brownish. The contractor must intimate the engineer in charge prior to addition in concrete for recording. If the admixture is put in the concrete mix at the batching plant, a written record of the amount of admixture used shall be supplied to the engineer. The engineer must ensure that the specified dosage of admixture is added in the concrete mix. (Material Cost Analysis only)

6257.01

-

-

... More
Providing and applying two coats of protective membrane over the cured concrete surface like R.C.C. footings, columns, plinth beams etc. which will be submerged under soil so as to protect the same. Apply two pack coal tar epoxy system of Sune poxy Coal tar of approved make & approved by Engineerin charge, having solid content ranges from 80-100 %, Tack free time 4-6 hrs. Recoat after 16-24 hrs. Mix Part A and Part B of Sun epoxy Coal tar of approved make & approved by Engineer in charge in 1:1 ratio with slow speed stirrer and apply the same on a clean R.C.C. surface by brush. Allow to set for 8-10 hours and apply the second coat. The rate to include for application at all levels to various RCC elements to the satisfaction of the EIC etc. complete.

4010.51

-

-

... More
Providing and fixing 90 centi metre x 60 centi metre Granite plate engraving 10 centi metre height letter, figures including painting the lefters/figures with approved colour and shade complete

1

-

-

... More
Providing and fixing in position alluminium strips of size 50 mili metre x 3 mili metre for nosing the steps including fixing with screws and raval plugs, bending and cutting to the required shape and size, finishing with paint, necessary mortar bedding of 1:3 cement mortar to get exact line and level including watering and curing etcetera complete

-

-

-

... More
A] Ground Floor

144

-

-

... More
B] First Floor

144

-

-

... More
Providing and fixing lioghtening conductor system comprising of erecting Air-Termination consisting of tubular copper rod of 25 mili metre diametre 1.2 mili metre thick with multiple points head 1.2 Metric Tonne. long ( Heavy Duty) welded or clamped to Galvanised Iron pipe pole B grade 50 mili metre diametre of requiired length with Mild Steel round bnase plate 25 centi metre diam and 10 mili metre thick at bottom embeded in cement concrete 1:3:6 dfoundation of size 45 centi metre diam x 45 centi metre Height and providing earthing with copper earth plate of size 60 x 60 x 0.3 centi metre with cadmium plated nut bolts to fix earthing strip burried in specially prepared earth pits 1.5 metre below ground level with 40 Kilogram charcoal and salt with altemate layers of charcoal and salt and Galvanised Iron pipe 40 mili metre diametre 2 meter length burried in earthe upto earthling plate remining portion above ground level for watering and refilling comcpete Note- Copper strip fropm lightening conductor is not considered in this item.

2

-

-

... More
Supply, fixing and installation of 4mm thick Aluminium Composite Panel (ACP) of approved colour for external cladding in combination of solid and metallic colours, including all necessary Framework, support and complete weather sealing as per architectural drawing. The Aluminium Composite Panel (ACP) should be made out of thermoplastic core of low-density polyethylene LDPE (100% virgin mix), sandwiched between two aluminium sheets of ALLOY GRADE- 5000 series, each not less than 0.50 mm thick, total thickness of aluminium composite panels not to be less than 4 mm, the exposed surface thereof shall have Stove lacquered finishing coat not less than (26 + - 2) micron (containing minimum 70% kynar 500 based PVDF) of colour and shade as per architectural design. The inside surface (facing the building exterior surface)shall have polyster based powder coating not less than 25 Micron with protective peel-off foil on the exterior face (peel off film will in no case leave any adhesive mark over the composite panel surface after it is peeled off). The supporting framework shall be made out of 50 mm X25mm X 3mm thick Aluminium section to be spaced horizontally and vertically for fixing of panel of size 900 mm X 1200 mm and fixed to the building structure as per design through 50mm X50mm X5 mm MS angle clamps prefixed to masonry or slab, columns with Hilti make anchor fastener screws. The fixing of panel to be done with the help of VHB tapes and screws and all the sealing of joints to be done with weather sealent Silicon as directed by Engineer-in-charge. (Prior permission of S.E. is necessary before inclusion of this item in estimate)

17.57

-

-

... More
Providing soak pit of size 120 centi metre x 120 centi metre x 120 centi metre including excavating and filling with brick-bats.

2

-

-

... More
RWH - Shallow Percolation Pit providing, constructing 2.0m deep shallow depth percolation pit comprising of 1.0m dia pre-cast Reinforced Cement Concrete rings, 300 mili metre thick side filling around outside of Reinforced Cement Concrete rings (annular space) with 40 mili metre size boulders including filling of percolation pit up to 0.5m depth (from bottom up) with 25-75 mili metre clean washed gravels followed by 0.5m depth of 10-25 mili metre of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand VSI grade finely washed etcetera) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand VSI grade finely washed etcetera) media layer including covering with Reinforced Cement Concrete slab, manhole frame & cover, Polyvenyle Chloride rungs etcetera including arrangement for inlet & outlet pipe, excavation & backfilling as shown in the drawing. The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge

2

-

-

... More
Providing and installing bio digester unit based on DRDO technology made of fibre reinforced plastic (FRP) having composition and following technical specifications and including necessary pipe and accessories up to 3 meter length, excluding the necessary excavation for installing the bio digester. Percentage of fibre glass (glass content in fibre glass should be minimum 30%): -33.33% Percentage of polyester resin: - 66.67% Water absorption (as per ASTM):-0.30% Flammability as per ASTM Tensile strength:-115 MPA Specific Gravity at 25 degree centigrade 1.45 Izod impact strength:-65KJ/M2 Heat defection/distort temperature:-65deg C Corrosion resistance (Non Corrosive) fitted with Inlet pipe size rigid Polyvenyle Chloride: -100 mili metre Outlet pipe size rigid Polyvenyle Chloride:-80 mili metre Gas outlet rigid Polyvenyle Chloride with Valve: 20 mili metre Bacteria immobilization Polyvenyle Chloride mattes (on all partition) With DRDO TOT licensee and latest batch certificate(month & year of supply) and capacity as below c) Up to 25 user size (1.50 metrex1.0mx1.0m), Capacity of biodgester:-1500 liters, Area of top, bottom and side walls:- 8 Square Metre, Area of partition walls: 2 Square Metre, Total weight of frp: - 82.80 Kilogram, Bacteria inoculums quantity: - 600 liters, Minimum thickness of side walls / top and bottom: 5 mili metre, Number of inside partitions: - 3, Minimum thickness of partition wall: 3 mili metre

2

-

-

... More
Providing and installing bio digester unit based on DRDO technology made of fibre reinforced plastic (FRP) having composition and following technical specifications and including necessary pipe and accessories up to 3 meter length, excluding the necessary excavation for installing the bio digester. Percentage of fibre glass (glass content in fibre glass should be minimum 30%): -33.33% Percentage of polyester resin: - 66.67% Water absorption (as per ASTM):-0.30% Flammability as per ASTM Tensile strength:-115 MPA Specific Gravity at 25 degree centigrade 1.45 Izod impact strength:-65KJ/M2 Heat defection/distort temperature:-65deg C Corrosion resistance (Non Corrosive) fitted with Inlet pipe size rigid Polyvenyle Chloride: -100 mili metre Outlet pipe size rigid Polyvenyle Chloride:-80 mili metre Gas outlet rigid Polyvenyle Chloride with Valve: 20 mili metre Bacteria immobilization Polyvenyle Chloride mattes (on all partition) With DRDO TOT licensee and latest batch certificate(month & year of supply) and capacity as below d) Up to 40 user size (2.0mx1.0mx1.0m), Capacity of biodgester:-2000 liters, Area of top, bottom and side walls: - 10 Square Metre, Area of partition walls: 3 Square Metre, Total weight of frp: - 106.20 Kilogram, Bacteria inoculums quantity: - 600 liters, Minimum thickness of side walls / top and bottom: 5 mili metre, Number of inside partitions: - 3, Minimum thickness of partition wall: 3 mili metre

2

-

-

... More
Design, supply, fabrication and fixing acrylic multilingual Braille (raised dots) signboards of size 6"x 9" for room titles, designed as per the drawings issued and having 4 mili metre thick blue acrylic base plate with Upper Case San Serif words made of white acrylic non glare cut out letters of height 15 mili metre raised not less than 0.8mm above base plate and the equivalent word/s written in Hindi with Devnagri non glare acrylic letters of height 15 mili metre raised not less than 0.8mm above base plate. Grade 2/ Grade 1 Braille to be integral with the sign face and be raised 0.5 mili metre above base plate.Each signboard to be fixed as per manufacturers specifications on the wall adjoining the respective room door at a height of 1200 mili metre from FFL and as per the directions by the engineer in charge.

-

-

-

... More
A] Ground Floor

60

-

-

... More
B] First Floor

60

-

-

... More
C] Second Floor

10

-

-

... More
Providing and fixing board displaying information, such as 'Name of work, Tender cost, Name of Contractor, Work completion and liability period etcetera', having rectangular shape of 1.20 metre x 0.90 metre size made out 18 gauge (1.25 mili metre) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols etcetera with approved colour shade paint complete, on Mild Steelangle of size 35 x 35 x 3 mili metre frame with properly cross braced Mild Steel angles of size 35 mili metrex35 mili metrex3 mili metre duly painted including Two Mild Steel angle iron posts of size 65 mili metre x 65 mili metre x 6 mili metre, 3.65 meter long painted with alternate black and white bands of 25 Centi Metre width including all fixtures etceteraand fixing the boards in 1:4:8 concrete block of size 60 Centi Metre x 60 Centi Metre x 75 Centi Metre including, excavation, refilling, transportation, and labour etcetera complete. Spec. No. As directed by Engineer in Charge

1

-

-

... More
Providing and laying in situ /Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for Reinforced Cement Concrete work in foundations like raft, strip foundations, grillage and footings of Reinforced Cement Concrete columns and steel stanchions etcetera including bailing out water, Steel centering formwork, laying/ pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etcetera complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Crushed sand VSI Grade)

22.89

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for Reinforced Cement Concrete columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etcetera complete,(Excluding reinforcement and structural steel) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Crushed sand VSI Grade)

2.04

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for Reinforced Cement Concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/ pumping, compactionand roughening the surface if special finish is to be provided and curing etcetera complete. (Excluding reinforcement and structural steel) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Crushed sand VSI Grade)

2.29

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap/ granite / quartzite/ gneiss metal for Reinforced Cement Concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etcetera complete,(Excluding reinforcement and structural steel) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Crushed sand VSI Grade)

14.87

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/ pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Crushed sand VSI Grade)

0.07

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete pardi of required thickness including steel centering, formwork, cover blocks, laying/ pumping, compacting, curing, finishing and rougheningthem if special finish is to be provided and curing complete.(Excluding reinforcement and structural steel) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Crushed sand VSI Grade)

29.83

-

-

... More
Providing fly ash brick masonry with conventional/ Indian Standard type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etcetera Complete

4.51

-

-

... More
Providing internal cement plaster 12 mili metre thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etcetera complete.

307.6

-

-

... More
Providing neeru finish to plastered surfaces in all positions including scaffolding and curing etcetera complete.

24.46

-

-

... More
Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 mili metre to 605 mili metre x 590 mili metre to 605 mili metre of 8 to 10 mili metre thickness and confirming to Indian Standard 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etcetera complete.

8.54

-

-

... More
Providing and laying vitrified mirror / glossy finish tiles having size 590 mili metre to 605 mili metre x 590 mili metre to 605 mili metre of 8 to 10 mili metre thickness and confirming to Indian Standard 15622-2006 ( group Bla) of approved make, shade and pattern for dado & skirting in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etcetera complete.

1.17

-

-

... More
Providing and applying three coats of water proof cement paint of approved manufacture and of approved colour to new plastered surfaces including scaffolding if necessary, cleaning and preparing the surface, watering for two days etcetera complete.

77.23

-

-

... More
Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 mili metre with lock plate of 3.15 mili metre thickness reinforced with 35 x 35 x 5 mili metre angle section fitted with sliding bolts and handles for both sides, deep Mild Steel channel section of depth and thickness not less than 65 mili metre and 3.15 mili metre respectively with hold fast arrangements, Mild Steel Bracket plate 300 x 300 x 3.15 mili metre minimum size and shape with square bar, suspension shaft of minimum 32 mili metre diametre, hood cover of Mild Steel sheet not less than 0.9 mili metre thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etcetera complete. (Indian Standard 62481979) (With mechanical gear)

5.8

-

-

... More
Providing and fixing mild steel grill work for windows, ventilators, etcetera 15 Kilogram/Square Metre as per drawing including fixtures necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting complete.

3.6

-

-

... More
Boring work (including transport.) 200/215 mm diameter in the soil / gravel surface Bore diameter of 150 mm in solid rock. This includes diameter drilling work. (Wet drilling) MJP Bore Well

60

-

-

... More
After completion of drilling bore well, capacity test by flushing (air lift method) is measured with 90 degree "V" notch. MJP Bore Well

1

-

-

... More
180 mm diameter PVC Casing pipe (8 kg / cm2) (IS 4985-1988) In exceptional circumstances / Casing pipes with a rock surface and if more than 40 feet of casing pipe is required, the casing should be used with the technical approval of the Deputy Engineer and Geologist

10

-

-

... More
180 mm diameter PVC Casing pipe (8 kg / cm2) (IS 4985-1988) Casing lowering, grounding

10

-

-

... More
180 mm diameter cap for PVC pipe.

1

-

-

... More
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.

1232

-

-

... More
Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.

6296

-

-

... More
Supplying and erecting 25 mm dia. corrugated flexible polypropylene conduit

60

-

-

... More
Supplying and erecting PVC trunking (PVC casing-n-capping) of size 32 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.

1375

-

-

... More
Supplying and erecting PVC trunking (PVC casing-n-capping) of size 40 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.

415

-

-

... More
Supplying and erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW

10500

-

-

... More
Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW

5250

-

-

... More
Supplying and erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW

8875

-

-

... More
Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW

8875

-

-

... More
Supplying and erecting mains with 1x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW

2022

-

-

... More
Supplying and erecting mains with 2x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW

375

-

-

... More
Supplying and erecting mains with 4x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW

1235

-

-

... More
Supplying and erecting mains with 4x10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW

412

-

-

... More
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.

521

-

-

... More
Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete.

365

-

-

... More
Supplying and erecting modular type bell-push 6A / 10A duly erected on provided plate and box with wiring connections complete.

30

-

-

... More
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.

515

-

-

... More
Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.

375

-

-

... More
Supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete.

265

-

-

... More
Supplying and erecting modular type blanking plate one module, duly erected on provided plate & box.

25

-

-

... More
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.

34

-

-

... More
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.

82

-

-

... More
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.

4

-

-

... More
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 4 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.

6

-

-

... More
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.

144

-

-

... More
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 8 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.

143

-

-

... More
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.

74

-

-

... More
Supplying and erecting 6 to 32 A, 10kA, SPMCB suitable to fix in 1 module of modular switch in provided box complete & duly concealed with necessary material and connected.

217

-

-

... More
Supplying and erecting 16 to 32 A, 10kA, DPMCB suitable to fix in 2 module of modular switch in provided box complete & duly concealed with necessary material and connected.

10

-

-

... More
Point wiring for light/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/HW

589

-

-

... More
Point wiring for ceiling fan (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/HW

265

-

-

... More
Point wiring for light/bell/exhaust fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW

245

-

-

... More
Wiring for plug on board with Switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WG-PW/CW

210

-

-

... More
Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD10%, p.f. 0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.

15

-

-

... More
Supplying and erecting LED Panel Light(600mm X 600mm) Max. 35 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min 4200 Lumens, min. efficacy of 120 lumen/W, CRI80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD10%, p.f. 0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.

549

-

-

... More
Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI80, CCT upto 6500K, Beam Angle of 120 deg., THD10%, p.f. 0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty.

68

-

-

... More
Supplying & erecting inverter LED batten 20W tube light fitting with polycarbonate housing, heat sink, integrated HF electronic driver, Min. 2600 mAh Lithium ion Battery with charging time of 8-10 Hours and backup time of Min. 3 hrs. with minimum 25% of initial Watts having luminous efficacy of 100 lumen/watt, CRI80, CCT of 6500K and THD=20% having useful life of minimum 25000 hrs. with overheating protection with 2 years warranty.

105

-

-

... More
Supplying and erecting ding dong / electronic musical type call bell with heavy duty coil suitable to operate on 230V A.C. supply erected on polished double wooden block/sunmica block of suitable size.

30

-

-

... More
Supplying and erecting exhaust fan medium duty 230 V A.C. 50 cycles 225 mm. 1400 RPM with condenser complete erected in position with necessary materials. Fan motor with moisture proof treatment and ‘E’ class insulation.

57

-

-

... More
Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of 28W having service ratio (CMM/W) of Min. 8 , PF0.9, THD10% with IR remote control/compatible speed regulator, Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF

265

-

-

... More
Supplying and erecting fan hook of 10 mm. M.S. round bar grouted in RCC slab with making the site as original.

265

-

-

... More
Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire.

265

-

-

... More
Supplying, erecting, testing and commissioning self contained water cooler 230/250V 50Hz nominal cooling capacity of 150 litres per hour and storage capacity 150 litres with partially stainless steel body as per specification no. AP-WCR/WC

4

-

-

... More
Supplying and erecting fully automatic line voltage stabilizer buck and boost type for operation on input voltage 160-270 V and output voltage 200-250V rated for 5kVA maximum load and with voltmeter, selector switch, 6A/16A flush type 3 pin socket for output and with 3 core copper flexible cord and 3 pin 6/16A plug top with overload & short circuit protection complete .

4

-

-

... More
Supplying and erecting ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps with output of purified water minimum 0.33 litre/min with activated carbon filter and softener operating on 230V, single phase A.C. supply with UV fail & filter change indication system .(for TDS more than 200)

4

-

-

... More
Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

135

-

-

... More
Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

119

-

-

... More
Supplying, erecting & marking DPMCB 40A to 63A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

3

-

-

... More
Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

36

-

-

... More
Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

22

-

-

... More
Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 4 ways/phase (12 poles), with door, 1.2mm thickness, surface/flush mounted, IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB

20

-

-

... More
Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB

3

-

-

... More
Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame.

31

-

-

... More
Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/ 4 pole MCCB as incomer & outgoing SP MCB (12 poles) or TP MCB of 4 ways (12 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1

4

-

-

... More
Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/4 pole MCCB as incomer & outgoing SP MCB (24 poles) or TP MCB of 8 ways (24 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1

2

-

-

... More
Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB

14

-

-

... More
Providing & erecting 4 Pole MCCB 415V, 250A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB

2

-

-

... More
Providing & erecting 4 Pole MCCB 415V, 400A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure /panel as per specification no. SW-SWR/MCCB

2

-

-

... More
Supplying, erecting & commissioning 2 pole RCCB 40A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB

3

-

-

... More
Supplying, erecting & commissioning 4 pole RCCB 63A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB

21

-

-

... More
Providing & erecting floor/wall mounting, MCCB panel board, with door, suitable for four pole incoming 250A, 8 ways Four pole outgoing, up to 100 A MCCBs on iron frame, as per specification no SW-SWR/MCCBPB. (Excluding MCCBs)

1

-

-

... More
Providing & erecting incoming and outgoing cable alleys suitable for MCCB panel board with door, 250A incoming and 8 way outgoing or 400A incoming and 6 way outgoing made from CRCA sheet 1.6 mm thick duly powder coated and having vertical insulated partition for shielding between the shared face of cableway and DB.

1

-

-

... More
Providing & erecting prewired meter module suitable for MCCB panel board with CTs and emfs VIF meter.

1

-

-

... More
Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete.

135

-

-

... More
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.

88

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

256

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 150 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

115

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 4 sq mm copper conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU

152

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU

152

-

-

... More
Supplying & erecting G.I. pipe ‘A’ class 50 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE

12

-

-

... More
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 90 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.

90

-

-

... More
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP

10

-

-

... More
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.

85

-

-

... More
Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete.

14

-

-

... More
Caution Board (6.1.16) Supplying and erecting GI sheet 1.6mm (16 SWG) caution board of size 250 x 200 mm duly painted with red oxide and enamel paint in Marathi, Hindi and English erected at position for HV/EHV (11000 Volts) installation with compliance to IS 2551-1982

14

-

-

... More
Iron Work (6.1.19) Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.

20

-

-

... More
D.T.C. meter (6.3.5) Supplying and erecting LT CT multifunction DLMS compliance energy meter of accuracy of class 0.5 , 3x240V,50 Hz with optical & RS 232 port, backlit LCD, measure & display trivector energy, load survey, TOD, tamper detection & logging, power ON /OFF events, instantaneous parameters of rating 1/5 A with display in absence of power complete with zero adjustment & test certificate from manufacturer erected on provided M.S. box and connected to CTs.

1

-

-

... More
L.T. (6.5.2) Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates.

3

-

-

... More
Girder Pole (8.1.13) Supplying and erecting rolled steel joist (girder) pole 100 x 116 mm (23 kg/m) with base plate in provided foundation as per specification no. OH-PL/RSJ

140

-

-

... More
V Cross Arm (8.3.12) Supplying and erecting V cross arm with ISM channel of 75x40x6mm for 11kV HT OH line with arrangement to fix insulator at 45mm from the end & horizontal distance between insulators 1220mm bent at angle of 60 degree keeping base 305mm and the total vertical height of V cross arm as 460mm, and fixed on pole with MS clamp of 80x10 mm, nut bolts, washers complete as per specification no. OH-PL/VCA

11

-

-

... More
Top Clamp (8.3.14) Supplying and erecting 75x40 x6mm with 4.4mm thick web and 7.3mm thick flange channel (top pin) with clamp of suitable length so as to maintain vertical clearance of 1065mm for 11kV, 1320mm for 22kV between insulators for erection of top pin insulators complete as per specification no. OH-PL/VCA

11

-

-

... More
Guarding Bracket (8.3.15) Supplying and erecting bracket for guarding of HT OH Line, made from channel iron 1600mm in length and 75x40x6mm. erected on pole complete as per specification no. OH-PL/VCA

6

-

-

... More
Single Pole cut Point (8.3.17) Supplying & erecting single pole cut point channel set of for 11kV HT OH line two channel of size 100x50x6mm 1.6m long having stud angle of size 50x50x6mm 1.5m long with necessary clamps, nut bolts etc. complete as per drawing.

3

-

-

... More
D.P. Structure (8.3.26) Supplying & erecting end pole D. P. Structure for 11/0.415 kV, 200 kVA Transformer with R.S.J. Pole 2 Nos. of size 100mm x 116 mm x 11 m Long with suitable Distribution Box of C.R.C.A. Sheet 16 SWG with 4 Pole MCCB 400 Amps as incomer & 6 Nos.200 Amps Kitkat / MCCB for out going circuits. Transformer D.P. Structure includes the A. B. Switch 200 Amps, D.O. fuse Set & L.A. Set. 2 Nos. Top channel of size 100 mmx 50 mm for erection of A.B. Switch & 2 Nos. Base channel of size 100 mm x 50 x mm for erecting Transformer. Channel of size 75 x40 mm for erecting D.O. Fuse Set, L.A., A.B. Switch handle etc. Angle of size 50 x 50 x6 mm for erecting Distribution Box , Transformer Belt etc.as per drawing (min. 124 Kg. iron work) with necessary clamps, Nut-bolts. V cross arm, top clip, insulators etc. complete with caution board & barbed wire. D.P. Structure shall be erected in c.c. foundation complete.

1

-

-

... More
ACSR Conductor (8.4.7) Supplying and erecting ACSR conductor of size 6/1-2.59 mm complete. (Weasel) (127.7 kg/km) as per specification No. OH- CON/ACSR

2.26

-

-

... More
Disc Insulator (8.5.6) Supplying and erecting porcelain disc type insulator 45KN with necessary hardware suitable for 11kV line, complete as per specification no. OH-INS/DI

9

-

-

... More
Pin Insulator (8.5.9) Supplying and erecting porcelain pin type insulator with GI pin suitable for 11kV line, complete as per specification no. OH-INS/PN

39

-

-

... More
G.I. Stay (8.6.2) Supplying and erecting G.I. stay set for poles, including loop insulators at inaccessible height with anchor plate 300x300x6 mm., straining screws, G.l. stay wire 7/8 SWG, G.l. stay rod 20mmx1.8m length and pole clamps duly erected in provided cement concrete foundation complete.

4

-

-

... More
Guarding Lace (8.6.18) Supplying and erecting guarding lace for HT OH line with 8SWG G.l. wire to protect the HT OH line with binding wire of 20SWG G.l. wire for 75mm section on either side.

90

-

-

... More
Galvanized Iron Earth Plate (9.1.3) Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials, testing & recording the results as per specification no. EA- EP

6

-

-

... More
Pipe Type Earthing (9.1.4) Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP

18

-

-

... More
G.I.Strep (9.2.3) Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.

80

-

-

... More
G.I. Earth Wire (9.2.5) Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete.

40

-

-

... More
Transformer 200 KVA (Non CSR) Supplying, installing, testing & commissioning 3 phase, 11/0.433 kV, 50 Hz., 200 kVA, Mineral oil immersed and naturally cooled outdoor type, alluminium wound Non-sealed transformer delta/star connected with additional neutral brought out on load side, temperature rise should not exceed 45℃ by thermometer in oil and 50 ℃ by the resistance method in winding at full load rating, using type A winding insulation (kraft paper) with HV tapping (with off load tap changer)off load +2.5 to -5 in steps of 2.5%, having 4 number of tap positions, with standard accessories complete with test certificate with losses below 780 Watts at 50% load, 2300 Watts at 100% load as per IS:1180 (part 1) : 2014 , with necessary permissions of Electrical Inspector, as per specification no SS- TR-NSL. (Vide Est. No. 4133/22-23 Approved by SE, PW Electrical Circle, Nanded)

1

-

-

... More
C.C. Foundation (16.3.4) Making cement concrete foundation including excavation (60 x 60) cm x deep 1/6 of pole length in 1:3:6 cement concrete 20 x 25 mm stone metal, 45 cm x 45 cm x 45 cm /45 cm dia. x 45 cm. height plinth duly plastered, with necessary curing and finishing complete. (for above 9 m poles)

14

-

-

... More
C.C. Foundation (16.3.6) Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete, (20 to 25) mm stone metal with necessary curing and finishing complete.(for stay).

4

-

-

... More
MSEDCL 1.3 Supervision Charges

1

-

-

... More
Supplying, fixing, and configuring 8-ports managed gigabit, Layer-2 switch, 10/100/1000 base-T, POE smart switch plus 2 SFP erected in provided rack complete.

6

-

-

... More
Supplying, fixing, and configuring 24 ports, POE switch in provided rack as per specification No. WG-NWC/ENS

2

-

-

... More
Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x600x367 mm) as per specification No. WG-NAS/RAK

6

-

-

... More
Supplying and fixing 9U wall mount rack (Dimension-DxWxH – 500x600x500 mm) as per specification No. WG-NAS/RAK

2

-

-

... More
Supplying & erecting of High definition 4/5 Megapixel IP IR Dome Camera with following features Image Sensor : minimum 1/2.8" Progressive Scan CMOS, Video Resolution : minimum 2592 x 1520 Video Compression : H.264, H.265 or higher, at least Three individually configurable stream, Frame rate : minimum 25 fps at all resolutions, WDR : minimum 120 dB Wide Dynamic Range, ONVIF profile conformant, minimum IR distance : 50m, Lens Type : 2.8/4/6 mm Lens, fixed focal, Field of View : 2.8 mm, horizontal FOV 107°, vertical FOV 57°, diagonal FOV 129° 4 mm, horizontal FOV 86°, vertical FOV 47°, diagonal FOV 102° 6 mm, horizontal FOV 55°, vertical FOV 29°, diagonal FOV 65° Lux sensitivity - minimum 0.2 Lux at color, minimum 0.05 Lux at Black & White, 0.0 Lux (IR) Night Vision Distance minimum IR - 50m. Camera minimum Adjustment Angles - Pan : 350°, Tilt : 72°, Rotate : 350°. Power Supply : Support 12VDC & PoE, IP67, IK10 - Vandal Resistant. Built in micro SD/SDHC/SDXC card slot of minimum 128 GB, Built in microphone. minimum Input/Output - Audio in × 1, Audio Out × 1, Alarm in × 1, Alarm Out × 1. Image Settings : Rotate mode, saturation, brightness, contrast, sharpness, gain, white balance. Image Enhancements : Day/Night-Auto (ICR)/Color/Black & White, 3D Digital Noise Reduction, Automatic White Balance, Automatic Gain Control, Backlight Compensation, Highlight Compensation. (Vide Est. No. 4133/22-23 Approved by SE, PW Electrical Circle, Nanded)

30

-

-

... More
Supplying & erecting of High definition 4/5 Megapixel IP IR Bullet Camera with following features Image Sensor : minimum 1/2.8" Progressive Scan CMOS, Video Resolution : minimum 2592 x 1520 Video Compression : H.264, H.265 or higher, at least Three individually configurable stream, Frame rate : minimum 25 fps at all resolutions, WDR : minimum 120 dB Wide Dynamic Range, ONVIF profile conformant, minimum IR distance : 50m, Lens Type : 2.8/4/6 mm Lens, fixed focal, Field of View : 2.8 mm, horizontal FOV 107°, vertical FOV 57°, diagonal FOV 129° 4 mm, horizontal FOV 86°, vertical FOV 47°, diagonal FOV 102° 6 mm, horizontal FOV 55°, vertical FOV 29°, diagonal FOV 65° Lux sensitivity - minimum 0.2 Lux at color, minimum 0.05 Lux at Black & White, 0.0 Lux (IR) Night Vision Distance minimum IR - 50m. Camera minimum Adjustment Angles - Pan : 350°, Tilt : 72°, Rotate : 350°. Power Supply : Support 12VDC & PoE, IP67, IK10 - Vandal Resistant. Built in micro SD/SDHC/SDXC card slot of minimum 128 GB, Built in microphone. minimum Input/Output - Audio in × 1, Audio Out × 1, Alarm in × 1, Alarm Out × 1. Image Settings : Rotate mode, saturation, brightness, contrast, sharpness, gain, white balance. Image Enhancements : Day/Night-Auto (ICR)/Color/Black & White, 3D Digital Noise Reduction, Automatic White Balance, Automatic Gain Control, Backlight Compensation, Highlight Compensation. (Vide Est. No. 4133/22-23 Approved by SE, PW Electrical Circle, Nanded)

9

-

-

... More
Supplying, installing, testing & commissioning of 32/40 Ch. Network Video Recorder (NVR), suitable connect Min. 32 IP Cameras, up to 5 Megapixel Resolution, with HDMI/VGA outputs, provided HDMI output of 4K resolution or VGA output with output up to 1920 × 1080. Support H.265 or higher, H.264, MJPEG, Incoming Bandwidth 250Mbps with minimum 4 SATA Hard Disks, ANR Technology, 4 SATA interfaces for 4 HDDs and capacity of each HDD up to 8TB, minimum 02 USB port, Alarm I/O 16/4, RJ-45 10/100/ 1000 Mbps self-adaptive Ethernet interface, ONVIF conformance, Multiple network monitoring: Web viewer . support protocol TCP/IP, DHCP, DNS, DDNS, NTP, SADP, SMTP, NFS, iSCSI, UPnP™, HTTPS. RoHS, UL, CE, FCC certified. duly erected in provided U Rack with wiring connections, tagging and programming etc. complete as per specification no. CCTV-NVR (Vide Est. No. 4133/22-23 Approved by SE, PW Electrical Circle, Nanded)

2

-

-

... More
Supplying & erecting 8 TB internal Surveillance HDD suitable for SATA Port of NVR, interface transfer rate 6 GB/S, maximum sustained transfer rate 210 MB/Sec to 213 MB/S. Drive bay supported 08+, Cameras supported up to 64, Cache (MB) 256, Load/Unload Cycle -3000000, Work Load Rating per Year 180TB, MTBF 1000000 Hrs. HTTPS. RoHS, UL, CE certified, duly erected in position in provided NVR as per specification no. CCTV-HDD (Vide Est. No. 4133/22-23 Approved by SE, PW Electrical Circle, Nanded)

8

-

-

... More
Supplying & erecting 43" professional LED display with 1920*1080 (Full HD) Display, suitable for 16/32 channel NVR and following features Brightness: minimum 500 Cd/m2 Contrast Ratio: minimum 1000:1 Viewing angle: 178/178 deg. Response time: maximum 8 ms Inputs: HDMI, VGA, BNC,USB, Audio In, Built-in speakers maximum 10 W, Suitable to operate on 100-240 V 50 Hz AC supply and 24/7 Duty Cycle duly erected on wall or table top with standard accessories like wall mount stand and wiring connections etc. complete as per specifications no. CCTV-MON (Vide Est. No. 4133/22-23 Approved by SE, PW Electrical Circle, Nanded)

2

-

-

... More
Camera stand (NSCR) Supplying, installing and Comissining of CCTV Barcket for Dome and Bullet Camera Complete., Mounting Type Tripod, Wall Mount, Ceiling Mount Dimensions Lx WxH 8 x 5 x 8 Centimeters (Vide Est. No. 4133/22-23 Approved by SE, PW Electrical Circle, Nanded)

39

-

-

... More
Supplying and erecting modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connections complete.

62

-

-

... More
Supplying & erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/co

2480

-

-

... More
Supplying & erecting 10 pair, 0.5mm dia, jelly filled unarmoured telephone copper cable with poly-al laminate moisture barrier, laid in provided PVC casing capping/conduit as per specification No. WG-TW

80

-

-

... More
Supplying & erecting 20 pair, 0.5mm dia, jelly filled unarmoured telephone copper cable with poly-al laminate moisture barrier, laid in provided PVC casing capping/conduit as per specification No. WG-TW

240

-

-

... More
Supplying and erecting 15m HDMI cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete.

1

-

-

... More
Supplying, erecting & commissioning MDF Box 100x100 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW

1

-

-

... More
Supplying, erecting & commissioning 10 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TW

1

-

-

... More
Supplying, erecting & commissioning 20 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TW

3

-

-

... More
Supplying, erecting & commissioning 10 pair module for connection & disconnection of telephone cable as per specification no. WG-TW

14

-

-

... More
Supplying and installing, testing & commissioning of digital (hybrid) type EPABX of 6 x 32 extensions suitable upto 96 extensions complete.

1

-

-

... More
Supplying, installing, testing & commissioning push button telephone instrument desk top unit as per specification complete

55

-

-

... More
Supplying, installing, testing & commissioning IP telephone instrument as per specification complete.

7

-

-

... More
Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC

6065

-

-

... More
Supplying and fixing 1 m UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC

66

-

-

... More
Supplying, fixing, and configuring 24 ports with 4 (SFP+) port, ethernet managed switch with web view/CLI, 6KV surge protection on ethernet port and console port for management in provided rack as per specification no. WG-NWC/GBS

4

-

-

... More
Supplying and fixing tool-less IO (Ethernet) flush/surface type in provided modular box as per specification no. WG-NAS/IO

66

-

-

... More
Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP

12

-

-

... More
Supplying and erecting LSZH armoured multimode optical fibre cable with 6 fibres, core dia 50/125 µm (OM3), suitable upto 10 GBPS, ethernet distance at 850 nm of wavelength, on wall/ceiling or laid in provided pipe/trench as per specification no. WG-COC/O

215

-

-

... More
Supplying, fixing, and configuring 10G Base -SR (SFP+) simplex MM transceiver erected in provided rack complete.

4

-

-

... More
Flexible Conduit 25 mm (1.2.2) Supplying and erecting 25 mm dia. corrugated flexible polypropylene conduit

10

-

-

... More
Mains 2x6 sq.mm (1.3.4) Supplying and erecting mains with 2x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW

26

-

-

... More
FPMCB 40 A to 63 A (5.3.13) Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

3

-

-

... More
Change Over Switch (5.3.26) Supplying, fixing and commissioning MCB type change over switch 4 pole, 63A with 3 positions (I-O-II) with centre off position as per specification no. SW-SWR / MCBCOS

1

-

-

... More
TPNDB (5.4.4) Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 4 ways /12 Poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB

1

-

-

... More
MCB Enclosures (5.4.13) Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame.

3

-

-

... More
MCCB 03 Pole (5.5.1) Providing & erecting 3 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB

1

-

-

... More
CRCA Sheet (6.1.1) Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete.

100.78

-

-

... More
Iron Work (6.1.19) Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.

174.25

-

-

... More
FRXLPE 4x16 Cable (7.1.29) Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

230

-

-

... More
G.I. Pipe 40 mm (7.6.2) Supplying & erecting G.I. pipe ‘A’ class 40 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE

40

-

-

... More
D.W.C. Pipe 50 mm (7.6.9) Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.

193

-

-

... More
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP

3

-

-

... More
Submersible Pump Set (12.2.10) Supplying and erecting minimum Three & above star rated submersible pump set of 5.625 KW/7.5 HP with 415 V, 50 c/s AC supply suitable for 150 mm dia. borewell suitable for 110 to 510 LPM discharge at 107 to 30 m head & discharge & delivery pipe of Size-50 mm diameter with a necessary H type clamps as per specification No. WP-SMP

1

-

-

... More
Open Well Submersible Pump Set (12.3.2) Supplying and erecting minimum Three & above star rated submersible pump set suitable for erection on open well of 3.75 KW/5 HP with 415 V 50 c/s. A.C. supply, having delivery head from 43 to 11m and discharge from 120 to 840 litres. per minute & pipe of Suction 65mm / Delivery 50 mm diameter erected with necessary H type clamps as per specification No. WP-OSP

2

-

-

... More
Flat Flexible 3x4 sq.mm. Cable (12.4.9) Supplying & erecting flat flexible 3 core 4 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete.

185

-

-

... More
Automatic Control Panel (12.4.17) Supplying & erecting automatic control panel for 3 Phase , 415 volt, A.C, Submersible/centrifugal pump set up to 7.5 HP consisting of DOL starter having relay range 9-14 AMP,S.P.P., Combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc .

3

-

-

... More
C.C. Foundation (16.3.7) Making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose).

1

-

-

... More
G.I. Pipe 50 mm (16.5.6) Supplying and erecting ISI mark GI pipe 50 mm dia.‘B’ class at position with accessories complete as per specification no. CW- PLB/GP.

160

-

-

... More
Non Return Valve 50 mm Dia (16.6.21) Supplying and erecting non return valve 50 mm dia in position made of gun metal complete.

3

-

-

... More
SITC of Electric Traction Passenger cum Stretcher/Hospital Lift with ·       Rated capacity :- 15 Passenger/1020Kg ·       Floors :- G+1 floor (2 Stops/2 Landings) ·       Travel :- 3 to 4.2 mtrs ·       Location of Lift Machine:- MR/MRL [applicable for Passenger Lift with MRL only & Stretcher/Hospital Lift with MR & MRL] ·       Rated speed :- 1.0mps VS ·       Car/Landing door clear opening of 800/900/1000 mm wide x 2000mm high ·       Clear Car size of ......mm wide x ......mm deep x 2250mm high ·       Lift shaft available having clear size of ......mm wide x ......mm deep, ......mm Pit depth, ………mm Overhead. ·       Doors type :- COPO/TOPO Doors with frame made from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory). ·       Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge. ·       COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor. ·       LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings. ·       Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. ·       ARD complete with necessary SMF VRLA batteries. ·       Fireman controller having fireman switch at fire Landing. ·       CCTV surveillance system comprises of 2 nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days min. with 18” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge. ·       Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength. ·       Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work. ·       Minor civil work such as alteration work if any necessary for erection of landing door frames and it's accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT. · General: - Job includes entire procedure of obtaining all necessary erection permissions & "License to Work the Lift" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. · The above rate includes Fully Comprehensive AMC for one year from the date of commissioning.

2

-

-

... More
Supplying, installation, testing and commissioning of main fire pump (MFP / EP) suitable for water discharge of 2280 to 2850 LPM at 90 to 70 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 55kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal type, single stage, centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation on with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/EP

1

-

-

... More
Supplying, installation, testing and commissioning of main fire pump (MFP/DP) suitable for water discharge of 2280 to 2850 LPM at 90 to 60 m head driven by 76 HP or suitable HP capacity diesel engine at required working speed suitable for manual/automatic operation and consisting of following : (a) Horizontal type, single stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520. (b) Water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12/24 volts DC electric starting equipment with battery of required AH capacity with necessary charger suitable to work on 230v, 50Hz AC supply, diesel tank of minimum 150ltr capacity with first filling of diesel up to 100% level with necessary piping with valves up to engine , exhaust pipe extended up to 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications etc. as required. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with engine assembly and accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/DP

1

-

-

... More
Supplying, installation, testing and commissioning of jockey fire pump (JP) suitable for water discharge of 180 to 240 LPM at 110 to 90 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 11 kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal/vertical type, multi stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/JP

1

-

-

... More
Carrying out core cutting of size 3" to 5" dia x 15" length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original.

7

-

-

... More
Supplying, erecting, testing & commissioning of fire pump control panel (FCP) of cubical construction, floor mounted type, fabricated from minimum 2 mm thick CRCA sheet, compartmentalised with hinged lockable doors, with enclosure protection class IP54, duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnection with suitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessories, mountings and internal wiring with adequate size copper conductor cable, earth terminals, numbering etc. complete in all respect, suitable for satisfactory operation of main fire pump and jockey (pressurisation) pumps (1working+1standby) with necessary accessories, wiring & cabling along with allied accessories with following incoming and outgoings, suitable for automatic & manual operation on 415V, 3 phase, 50Hz ac supply as per specifications the capacity of electric motor driven pump are as follows a. Main fire pump(MFP) having capacity of 22kW 1no (1 working) b. Jockey pump(JP) capacity of suitable capacity 2 nos(1 working +1 standby, alternate run per start in auto mode) comprises of the following features & switchgears: 1. Main incomer FP SFU having rotary handle with HRC fuses of suitable rating. 2. Electrolytic grade copper strips for busbar of suitable sizes for main incomer and branches to motor SFU's, starters & outgoing terminals with necessary accessories like stainless steel nut bolts with spring washers for connections, mounted on required no of epoxy or porcelain support insulators of suitable ratings etc. 3. Individual pump TPN SFU having rotary handle with HRC fuses of suitable rating.

1

-

-

... More
For main electric motor driven fire hydrant system pump of 55kW capacity & relevant capacity jockey pump add Rs…

1

-

-

... More
for 5.5/ 7.5 kW centrifugal type booster pump 1no(1working) , add Rs…....

1

-

-

... More
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP

4

-

-

... More
Supplying and erecting G.I. pipe ‘C’ class ERW 150 mm dia with necessary fittings complete as per specification no. FF-PP

325

-

-

... More
Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm dia with necessary fittings complete as per specification no. FF-PP

160

-

-

... More
Supplying and erecting G.I. pipe ‘C’ class ERW 75/80 mm dia with necessary fittings complete as per specification no. FF-PP

15

-

-

... More
Supplying and erecting 75/80 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV

5

-

-

... More
Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV

8

-

-

... More
Supplying and erecting 75/80 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV

1

-

-

... More
Supplying and erecting 150 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV

2

-

-

... More
Supplying and erecting 150 mm dia cast iron foot valve ball type/flap type with strainer for negative suction complete as per specification no. FF-VL/FV

1

-

-

... More
Supplying and erecting 150 mm dia cast iron foot valve ball type/flap type with strainer for negative suction complete as per specification no. FF-VL/FV

2

-

-

... More
Supplying and erecting 25 mm dia gun metal gate valve complete with PN16 pressure rating, as per specification no. FF-VL/GV

17

-

-

... More
Supplying and erecting 20/25mm dia gun metal air release cock, with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV

2

-

-

... More
Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, erected with provided G.I. pipe, elbow etc. complete as per specification no. FF-FFA/PG

5

-

-

... More
Supplying and erecting 12/15 mm dia pressure switch with provided isolation valve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS

5

-

-

... More
Supplying and erecting 300 mm dia 1.5m in height air vessel / tank fabricated from min 5mm thick M.S. sheet complete as per specification no. FF-FFA/ACT

1

-

-

... More
Supplying and installing one piece moulded HDPE / fibre water tank for negative suction only, having capacity 1000 litres fitted with necessary accessories complete as per specification no. FF-FFA/PT

1

-

-

... More
Providing and fixing high-density polyethylene (HDPE) container one piece moulded triple layer water tank made out of high density polyethylene and built corrugated inclusive of delivery up to destination hoisting and fixing of accessories such as inlet,

5000

-

-

... More
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding

458

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 120 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as

60

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per

70

-

-

... More
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 90 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.

55

-

-

... More
Supplying, installing, testing and commissioning FR, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU

6350

-

-

... More
Supplying, installing, testing and commissioning FR, XLPE armoured cable 8 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU

40

-

-

... More
Supplying, installation, testing and commissioning of booster fire pump [BP] suitable for water discharge of 450 LPM at 35 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 5.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal/vertical type, single/multi stage, centrifugal casing pump of cast iron body & bronze/CI impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/BP

1

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per s

60

-

-

... More
Supplying and erecting stainless steel single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV

15

-

-

... More
Supplying and erecting M.S./CRCA cabinet for housing Floor Hydrant valve, hose pipe, hose reel and branch pipe (size 1000 x 736 x 736 mm.) made from 16 SWG sheet and angle iron 25 x 25 x 4 mm. having front doors with viewing glass (8"x6"

15

-

-

... More
Supplying and erecting 63mm dia, reinforced rubber lined (R.R.L.) hose pipe, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL

30

-

-

... More
Supplying and erecting stainless steel branch pipe 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specifications no. FF-FFA/NZ

15

-

-

... More
Supplying and installing wall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) along with necessary accessories complete as per specification no. FF-FFA/HV

15

-

-

... More
Supplying and erecting 150 mm dia fire brigade header suitable for supplying water in fire tank complete as per specification no. FF-FA/FBC

1

-

-

... More
Supplying and erecting fire brigade header ( Siamese connection )of 150 mm dia, for supplying water in fire tank complete as per specification no. FF-FA/FMC

1

-

-

... More
Supplying, installing, testing and commissioning of 8 Zones Microprocessor based conventional fire alarm control panel (FACP) with standard accessories , 16x2 Character LCD Display, provision for zone wise contact and beep sound alarm, suitable to operate on 120-220 V AC, 0 - 49 Deg C, 93 ± 2 Percentage RH (non- condensing) at 32 ± 2 Deg C complete as per specification no. FF-FAAS/FACP

2

-

-

... More
Supplying, erecting testing and commissioning optical type smoke detector on suitable back box with necessary connections complete as per specification no. FF-FAS/SD

254

-

-

... More
Supplying, erecting testing and commissioning heat detector with combination "ROR and Fixed Temp." complete as per specification no. FF-FAS/HD

2

-

-

... More
Supplying, erecting testing and commissioning manual call point (Pill box) with break glass, push button (resettable type) in metal enclosure complete as per specification no. FF-FAAS/MCP

10

-

-

... More
Supplying, erecting, testing and commissioning hooters having high (100dB @ 1m) and low (94dB @ 1m) volume setting, group addressing facility allowing multiple sounders to be activated with CRCA enclosure complete as per specification no. FF-FAAS/HTR

10

-

-

... More
Supplying & erecting four pole ON LOAD change over switch, 415V, 315-320A, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, op

1

-

-

... More
Supplying, erecting, testing and commissioning of diesel generating set with alternator of 200 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing

1

-

-

... More
Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 180 kVA up to 200 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no.

1

-

-

... More
Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results as per specification no. EA-EP

3

-

-

... More
Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EA-EP.

8

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 150 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per

106.59

-

-

... More
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 90 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.

70

-

-

... More
Supplying, installing, testing and commissioning of 50 kWp ON-GRID Solar PV System / Plant consisting Solar PV Poly Crystalline Panel (335 Wp X 150 Nos.) and Solar ON-GRID Inverter of similar capacity (THD3%) with interconnecting wires / cables up to solar ON GRID inverter, proper base plate, canopy box to house Inverter and necessary accessories i.e. ACDB/ DCDB , MCB etc. wiring up to solar Inverter in casing and capping, display board, sign board, two distinct earthing, lightning arrester, liaisoning charges, remote monitoring system with maintaining card / chip for 5 years including net charges for RMS System, complete up to net meter installation and export to the grid with 5 year ON-SITE warranty and fully comprehensive maintenance contract as per Specification no. ESD-RT-ONG. (25Kw= 1290208.50) + (25kw= 25x61656=) 1541400 = 2831608.50)

1

-

-

... More
Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact.

1

-

-

... More
Supplying and erecting SS enclosure for MCCB suitable for up to 100A MCCB.

1

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 95 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per

62

-

-

... More
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding

3060

-

-

... More
Supplying and erecting LT CT multifunction DLMS compliance energy meter of accuracy of class 0.5 , 3x240V,50 Hz with optical & RS 232 port, backlit LCD, measure & display trivector energy, load survey, TOD, tamper detection & logging, power ON /OFF ev

1

-

-

... More
Supplying and erecting AC three phase LT CT multifunction net meter DLMS compliance of accuracy class 0.5, 3 x 240V, 50Hz, with backlit LCD display, optical port & RS 232 port (measures import kWh, kVAh, export kWh, kVAh, Net kWh, kVAh, V, I, kW,

1

-

-

... More
Making cement concrete foundation in 1:2:4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) (for pumps).

13

-

-

... More
Supplying and erecting LT current with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates.

3

-

-

... More
Supplying, installation and testing of maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fi

4

-

-

... More
Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EA-EP.

54

-

-

... More
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.

14

-

-

... More
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP

2

-

-

... More
Supplying & erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pip

3

-

-

... More
Supplying, installation & marking of surge arrestor / surge protection device at the main distribution board after the incoming breaker of type 1+2 tested for Imax 100 kA for three phase and neutral with compliance to IEC 61643-11 as per specification

2

-

-

... More
Supplying & erecting three phase, 415V, street light control panel up to the max load of 6kW, TPN MCB 40A, powder coated CRCA 14 SWG sheet, outdoor type, having IP54,IK10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimu

1

-

-

... More
Supplying, erecting & marking SPMCB 0.5A to 5A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

20

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per s

560

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per s

85

-

-

... More
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.

525

-

-

... More
Providing & erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL

14

-

-

... More
Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT

8

-

-

... More
Providing and erecting galvanised 1000mm double arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT

6

-

-

... More
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP

1

-

-

... More
Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP

14

-

-

... More
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.

4

-

-

... More
Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete.

16

-

-

... More
Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly pla

14

-

-

... More
Supplying and erecting hylam sheet/ ebonite 6 mm thick for covering wall entries including cutting, drilling and fixing with nut bolts / screws etc. complete.

5

-

-

... More
Supplying & erecting 415V, 16A porcelain base neutral link complete erected in provided M.S. box.

56

-

-

... More
Supplying & erecting integral post top lantern fixtures (light house type) suitable upto LED 18 W Lamp consisting of combination of spun aluminium canopy & clear acrylic top cover, cast aluminium pole cap on provided pole/ bracket as per specification no. FG-ODF/PTL

4

-

-

... More
Supplying & erecting 18W, 230V integral type LED Lamp suitable for B-22 / E-27 base.

4

-

-

... More
Supplying & erecting FRP box of size 250mm x 200mm x 100 mm, 2.7 mm thick complete on pole/wall as per specification No. CB-SB

4

-

-

... More
Supplying & erecting G.I. pipe ‘A’ class 50 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE

25

-

-

... More
Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV

120

-

-

... More
Supplying and erecting integrated LED street light fitting 70-75W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 7700 Lumens, min. efficacy of 110 lumen/W, CRI70, CCT upto 6500K,THD10%, p

30

-

-

... More
Supplying and erecting street light Wall bracket made from 40 mm. dia ‘ G.I. pipe 1.2 m. in total length complete as per specification no. FG-BKT/WB

10

-

-

... More
Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.

60

-

-

... More
Supplying and erecting mains with 3x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW

70

-

-

... More
Carrying out core cutting of size 3" to 5" dia x 15" length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original.

4

-

-

... More
Providing adhesive thermal insulation for supply return air duct with 19mm nitrile rubber insulation having R-value as per the prevailing provisions in ECBC-2017.

70

-

-

... More
Providing and applying of acoustic insulation for air ducts with 25mm thick, 48 kg/cu.m fiber glass faced with RP tissue and covered with 26 SWG perforated aluminium sheets complete.

72.03

-

-

... More
Supplying & erecting tile type modular diffuser made from aluminium sheet with powder coated matching to the ceiling shade for provided supply and return air complete.

16

-

-

... More
Supplying and installing of collar damper of galvanised iron material of upto 120 microns for anti corrosive resistance for supply air grill of suitable size.

2

-

-

... More
supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 19.1mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for

45

-

-

... More
supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 22.2mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for

45

-

-

... More
Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 22 mm for solar water heater/AC system.

45

-

-

... More
Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 19 mm for solar water heater/AC system.

45

-

-

... More
Supplying and erecting 32/40 mm (ID/OD) Chlorinated polyvinyl chloride pipe (CPVC), thickness 3.8 mm conforming to IS 15778 (CTS Series) with necessary CPVC fittings and solvent cement for Solar Water Heater System as per specification No. ESD-HWP/CPVC

45

-

-

... More
Supplying and erecting GI sheet 0.6 mm (24 SWG) having zinc coating of 275 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, rivetin

60

-

-

... More
Supplying and erecting GI sheet 0.8 mm (22 SWG) having zinc coating of 275 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, rivetin

40

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per s

55

-

-

... More
Supply, installation, testing and commissioning of VRV / VRF based ductable type, high static room/indoor unit (IDU) having nominal cooling capacity of 5.1TR (2040 cfm) to 6.0TR 2400 cfm) having EER as per BEE standards and specifications with evaporator

2

-

-

... More
Supplying, erecting, testing and commissioning of 14HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacit

1

-

-

... More
Supplying and installation of high pressure grade required size copper connection Y or T- Joints/refnet complete erected on wall/ceiling with supports/raceways, Nitrile rubber insulation, painting etc. with brazing and testing for leakages confirming the

3

-

-

... More
Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor. room air conditioning unit 1.7TR to 2.0TR capacity having ISEER minimum 5.0 suitable to operate on 250V, 50

1

-

-

... More
Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 12mm complete.

10

-

-

... More
Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 16mm complete.

10

-

-

... More
Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 12 mm for solar water heater/AC system.

10

-

-

... More
Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 16 mm for solar water heater/AC system.

10

-

-

... More
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding

315

-

-

... More
Supplying and laying HMS PVC conduit FRLS grade 32mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.

105

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.