Public Works Department Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Public Works Department - PWD Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date20 Jan 2025
Closing Date15 Feb 2025
Tender Amount₹ 70,36,63,916 
Notes
Download

Costs

  • EMD

    ₹ 35,18,500
  • Document Cost

    ₹ 3,000
  • Tender Fee

    ₹ 500

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
c] Lift from 4.50 to 6.00 m

6188.8

-

-

... More
Excavation for foundation in Hard rock by chiselling, wedging, line drilling, etc. including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the building area stacking as directed, dewatering and back filling with available earth/ murum watering, ramming etc. complete.

7426.86

-

-

... More
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all loads including all lifts involved. for 5.00 Km Lead. Lead Of 5.00

7426.85

-

-

... More
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper.

4450

-

-

... More
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-I) to the soil along the external face of building by punching holes of 1.2 of 1.5 C.M. diametre about 30 -60 cm deep at 15 cm c/c as close to the wall as possible and to inject 0.5 percent of aldrin or clorophyrifos at the rate of 7.5 litres per hole and sealing the same with proper filling and covering 10 years guarantee on bond paper.

2670

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)

713.23

-

-

... More
Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete.

771.15

-

-

... More
Providing and fixing 20 to 25 mm thick rough shahabad box type waterproofing for basement or underground floor on a base of Cement concrete 1:3:6, including sub base of 2.50 centimeter thick Cement mortar 1:3 with conceal, secrete (RMW), Algae proof or other alike waterproofing liquids, raking of joints upto 35 mm depth, filling the joints with 6 mm size crushed metal, hand grouting with cement slurry, curing and cleaning, with 7 years guarantee on court fee stamp of Rs. 100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete )

111.04

-

-

... More
Providing and fixing 20 to 25 mm thick rough shahabad box type waterproofing treatment to vertical outside faces of Reinforced Cement concrete walls of basement or underground floor including filling the gap of 25 mm between rough shahabad and R.C.C. walls with cement grout mixed with water proofing liquid Algae proof or other alike with one tile lift method, brushing the joints horizontally with cement slurry mixed with water proofing liquid for width 30 to 35 mm and sloping coping over topmost tile with cement mortar 1:3, butting the bottom most with Cement concrete 1:2:4 mixed with water proofing liquid, curing, with 7 years guarantee on court fee stamp of Rs.100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete)

161.36

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. columns as per detailed designs and drawing or as directed including Steel centering formwork, cover blocks laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)

3540.87

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap / granite/quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) a] Ground Floor

673.62

-

-

... More
b] First Floor

310.22

-

-

... More
c] Second Floor

310.22

-

-

... More
d] Third Floor

268.11

-

-

... More
e] Fourth Floor

268.11

-

-

... More
f] Fifth Floor

361.67

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite/quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) a] Ground Floor

784.72

-

-

... More
b] First Floor

401.36

-

-

... More
c] Second Floor

325.67

-

-

... More
d] Third Floor

325.67

-

-

... More
e] Fourth Floor

325.67

-

-

... More
f] Fifth Floor

387.35

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) a] Ground Floor

1077.27

-

-

... More
b] First Floor

476.55

-

-

... More
c] Second Floor

372.53

-

-

... More
d] Third Floor

372.53

-

-

... More
e] Fourth Floor

372.53

-

-

... More
f] Fifth Floor

428.27

-

-

... More
Providing and laying Cast in situ/Ready Mixcement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) a] Ground Floor

18.85

-

-

... More
b] First Floor

18.85

-

-

... More
c] Second Floor

18.85

-

-

... More
d] Third Floor

18.85

-

-

... More
e] Fourth Floor

18.85

-

-

... More
f] Fifth Floor

18.85

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)

834.54

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap / quartzite/granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) a] Ground Floor

141.04

-

-

... More
b] First Floor

70.52

-

-

... More
c] Second Floor

70.52

-

-

... More
d] Third Floor

70.52

-

-

... More
e] Fourth Floor

70.52

-

-

... More
f] Fifth Floor

70.52

-

-

... More
Providing and fixing in position HCRM / CRS (Corrosion Resistant Steel) bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. a] Ground Floor

1002.16

-

-

... More
b] First Floor

240.13

-

-

... More
c] Second Floor

210.8

-

-

... More
d] Third Floor

200.28

-

-

... More
e] Fourth Floor

200.28

-

-

... More
f] Fifth Floor

244.66

-

-

... More
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per One Square Metre of surface area covering ten years guarantee on bond paper.

386.1

-

-

... More
Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete a] Ground Floor

510.07

-

-

... More
b] First Floor

486.17

-

-

... More
c] Second Floor

473.01

-

-

... More
d] Third Floor

448.82

-

-

... More
e] Fourth Floor

380.05

-

-

... More
f] Fifth Floor

534.72

-

-

... More
Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of 2 bars of 6 mm diameter / 2 hoop iron strips 25 mm X 1.6 mm placed at every third course, properly bent and bonded at ends scaffolding, racking out joints and watering etc.complete. a] Ground Floor

1496.54

-

-

... More
b] First Floor

1516.1

-

-

... More
c] Second Floor

1563.99

-

-

... More
d] Third Floor

1538.42

-

-

... More
e] Fourth Floor

1517.76

-

-

... More
f] Fifth Floor

1438.17

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C.coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including steel centering, formwork, cover blocks, laying/pumping, compacting , curing , finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) c] Second Floor

3.93

-

-

... More
e] Fourth Floor

2.26

-

-

... More
f] Fifth Floor

11.54

-

-

... More
Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete a] Ground Floor

6

-

-

... More
b] First Floor

6.15

-

-

... More
c] Second Floor

2.79

-

-

... More
d] Third Floor

4.3

-

-

... More
e] Fourth Floor

4.93

-

-

... More
f] Fifth Floor

3.8

-

-

... More
Providing and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/ One Square Metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. a] Ground Floor

204.84

-

-

... More
b] First Floor

256.86

-

-

... More
c] Second Floor

213.98

-

-

... More
d] Third Floor

206.96

-

-

... More
e] Fourth Floor

173.21

-

-

... More
f] Fifth Floor

136.22

-

-

... More
Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete. a] Ground Floor

3397.51

-

-

... More
b] First Floor

3234.17

-

-

... More
c] Second Floor

3023.17

-

-

... More
d] Third Floor

3080.53

-

-

... More
e] Fourth Floor

2697.72

-

-

... More
f] Fifth Floor

2496.94

-

-

... More
Providing internal cement plaster 12mm thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. a] Ground Floor

7441.84

-

-

... More
b] First Floor

6777.27

-

-

... More
c] Second Floor

6008.73

-

-

... More
d] Third Floor

6259.6

-

-

... More
e] Fourth Floor

5461.49

-

-

... More
f] Fifth Floor

5209.96

-

-

... More
Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete. a] Ground Floor

13681.75

-

-

... More
b] First Floor

8118.69

-

-

... More
c] Second Floor

7330.82

-

-

... More
d] Third Floor

7658.69

-

-

... More
e] Fourth Floor

6408.19

-

-

... More
f] Fifth Floor

6199.43

-

-

... More
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. a] Ground Floor

7994.92

-

-

... More
b] First Floor

2063.38

-

-

... More
c] Second Floor

1960.21

-

-

... More
d] Third Floor

1690.8

-

-

... More
e] Fourth Floor

1685.17

-

-

... More
f] Fifth Floor

3017.81

-

-

... More
Providing and applying Texture plaster with finishing with texture material of approved make in 3 to 4 millimeter thickness on previously plastered surface, including Plaster Groove 6mm thickness or Tape Grooves 35 to 45 mm thickness or as required, in all position including preparing the surface, scaffolding etc. complete. a] Ground Floor

799.49

-

-

... More
b] First Floor

206.34

-

-

... More
c] Second Floor

196.02

-

-

... More
d] Third Floor

169.08

-

-

... More
e] Fourth Floor

168.52

-

-

... More
f] Fifth Floor

301.78

-

-

... More
Labour charges for providing groove in external plaster having width and spaced as directed by engineer incharge etc. complete. a] Ground Floor

350

-

-

... More
b] First Floor

300

-

-

... More
c] Second Floor

250

-

-

... More
d] Third Floor

250

-

-

... More
e] Fourth Floor

220

-

-

... More
f] Fifth Floor

200

-

-

... More
Providing patti/ band 100mm wide on plastered surface 12 mm to 15 mm thick in C.M. 1:3 line and level including neat finishing scaffolding curing etc. complete. c] Second Floor

113.72

-

-

... More
e] Fourth Floor

63.92

-

-

... More
f] Fifth Floor

334.12

-

-

... More
Providing internal cement plaster 20mm. thick in Single coats in cement mortar 1:3 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete.

277

-

-

... More
Providing fine cement finish 1.5 mm thick over green plaster surface including scaffolding curing etc. complete.

277

-

-

... More
Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1Kilogramper bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete. c] Second Floor

729

-

-

... More
e] Fourth Floor

237.83

-

-

... More
f] Fifth Floor

2402.69

-

-

... More
Providing waterproofing in W.C. and bath including brick bat coba in all position including providing and laying 12mm bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound @ 1Kilogram/per bag of cement laying brick bat coba of required thickness in cm 1:5 with waterproofing compound 1 Kilogram/bag of cement grouting and finishing the top layer with 20mm thick brick bedding in cm mortor 1:3 with waterproofing compound 1 Kilogram/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etc. complete. a] Ground Floor

70.67

-

-

... More
b] First Floor

83.82

-

-

... More
c] Second Floor

78.05

-

-

... More
d] Third Floor

94.07

-

-

... More
e] Fourth Floor

92.17

-

-

... More
f] Fifth Floor

60.57

-

-

... More
Providing and laying vitrified matt fininsh tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete. a] Ground Floor

2794.89

-

-

... More
b] First Floor

1984.33

-

-

... More
c] Second Floor

1987.8

-

-

... More
d] Third Floor

2024.64

-

-

... More
e] Fourth Floor

1508.84

-

-

... More
f] Fifth Floor

1463.59

-

-

... More
Providing and laying vitrified matt finish tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. a] Ground Floor

697.86

-

-

... More
b] First Floor

387.4

-

-

... More
c] Second Floor

644.56

-

-

... More
d] Third Floor

395.09

-

-

... More
e] Fourth Floor

296.14

-

-

... More
f] Fifth Floor

468.67

-

-

... More
Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete. a] Ground Floor

555.61

-

-

... More
b] First Floor

160.7

-

-

... More
c] Second Floor

160.7

-

-

... More
d] Third Floor

160.7

-

-

... More
e] Fourth Floor

160.7

-

-

... More
f] Fifth Floor

160.7

-

-

... More
Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete. a] Ground Floor

211.5

-

-

... More
b] First Floor

95.76

-

-

... More
c] Second Floor

95.76

-

-

... More
d] Third Floor

95.76

-

-

... More
e] Fourth Floor

95.76

-

-

... More
f] Fifth Floor

95.76

-

-

... More
Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etc. complete. a] Ground Floor

238.38

-

-

... More
b] First Floor

245.1

-

-

... More
c] Second Floor

254.5

-

-

... More
d] Third Floor

186.93

-

-

... More
e] Fourth Floor

201.75

-

-

... More
f] Fifth Floor

165.45

-

-

... More
Providing and laying ceramic tiles having size 30 cm. x 60 cm. confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. a] Ground Floor

572.93

-

-

... More
b] First Floor

677.68

-

-

... More
c] Second Floor

641.33

-

-

... More
d] Third Floor

694.66

-

-

... More
e] Fourth Floor

743.68

-

-

... More
f] Fifth Floor

477.13

-

-

... More
Providing and laying Antiskid Ceramic tiles of approved quality of size 30 cm x 30 cm and confirming to IS 15622-2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete. a] Ground Floor

157.03

-

-

... More
b] First Floor

186.25

-

-

... More
c] Second Floor

364.18

-

-

... More
d] Third Floor

418.05

-

-

... More
e] Fourth Floor

409.62

-

-

... More
f] Fifth Floor

269.21

-

-

... More
Providing leather finished polishing to Granite Stone slab by continuous grinding in 4 coats of different bits to receive rough and matt finish including buffing process before laying and fixing of stone as per drawing and design, including cleaning, washing and finishing etc. complete.

2049.41

-

-

... More
Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 mm x 450 mm size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 mm thick supports with kadappah top 35 to 40 mm thick and polished granite 16 to 20 mm top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 cm height and top granite of 75 x 40 cm including cutting, opening for sink of required size in kadappah as well as granite etc. complete. (Platform top size 5.00 m x 0.60 m and height is 0.75 m)

67.5

-

-

... More
Providing and fixing heavy duty inter locking concrete Rubber mould glossy paving blocks of 80 mm thickness of having a strength of 400 Kilogram/Sq.cm. of approved quality and shape on a bed of crushed sand of 25 to 30 mm thick including skirting joints and cleaning etc. complete. (using 100% crushed sand)

675

-

-

... More
Providing and laying in situ cement concrete M30 with tremix treatment for 200 mm thickness for flooring with groove cutting of 4mm wide and 20mm deep with necessary refilling with bitumen etc. complete.

4193

-

-

... More
Providing and Fixing Processed Stone Cladding on wall surface/ plywood surface. RCC pardi/ Wall and all type of Interior, Exterior Compound wall and Gate etc. of cladding processed stone with material of Processed clay, Wooden chips, Silica sand, Cement, GFRC admixtures, Colour pigments, Fiber up to thick of 230 mm/ 25 mm including scaffolding, fixing of screw, etc. (As directed by Engineer in Charge)

200

-

-

... More
Providing and fixing 34 mm thick moulded door shutter consisting of solid core single leaf flush door of 30 mm thickness lipped with 15 mm ( 5mm x 3) thick x 30 mm width on one style and top rail and 10 mm (5mm x 2) thick x 30 mm width on other style and bottom rails. The inner panels laminated with 2 mm thick termite proof, water proof and fire resistant moulded PVC sheet with 2,4,6 design in different plain and /or prelim colours on one side after routing the moulded design on flush doors and 2 mm plain and /or pre lam PVC on other side using rubber adhesive on flush door and solvent cement adhesive on the PVC lipping etc. as per direction of Engineer in charge and manufacturers specification and drawing etc. complete. a] Ground Floor

200.4

-

-

... More
b] First Floor

196.5

-

-

... More
c] Second Floor

86.7

-

-

... More
d] Third Floor

144

-

-

... More
e] Fourth Floor

156.9

-

-

... More
f] Fifth Floor

120.3

-

-

... More
Providing and Fixing 30 MM thick BOTH SIDE PRELAMINATED SOLID PANEL PVC DOOR SHUTTER consisting of frame made out of M.S tubes of 19 guage thickness and, size 19 x 19 mm for styles and 15 x15 mm for the top and bottom rails, M.S frame shall have a coat of metel primer of approved make and manufacture. M.S frame shall be covered with heat mouled PVC 'C' channel made from 5 mm (+/0.25) thick prelaminated sheet of density 600 Kilogram/cbm ,of size 30mm thickness 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45? angle on either side forming stiles ; and 5 mm thick ,95 mm wide PVC sheet out of which 75 mm shall be falt and 20 mm shall be tapered in 45 on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be falt and 20 mm shall be tapered on both sides to form lock rail.Top,bottom and lock rail shall be provided either side of the panel. An additional 5 mm (+/0.25) thick PVC strip of 20 mm width is to be stuck on the bottom side of the ' c ' channel prelaminated paneling of 5 mm (+/0.25) thick PVC sheet to be fitted inside the M.S. frame welded/ sealed to the styles and rails with 5 mm (+/0.25) x 30 mm PVC sheet beading on either side and joined together with solvent cement adhesive etc ,10 mm thickness (5 mm (+/0.25) x 2 nos ) 20 mm wide cross PVC sheet as gap insert for the rail and bottom rail. Door to be fixed to frames with 3 nos M.S.powder coated but hinges of size 100 mm x 25MM x 2mm using 32 mm long steel screws drilled suitable to pass through both the walls of the M.S tube. Other hardwares a] Ground Floor

79.65

-

-

... More
b] First Floor

87.3

-

-

... More
c] Second Floor

78.75

-

-

... More
d] Third Floor

83.7

-

-

... More
e] Fourth Floor

85.5

-

-

... More
f] Fifth Floor

56.25

-

-

... More
Fire Door 45mm 1HR FRL (60/60) 3 Criteria - INTEGRITY / INSULATION/ STABILITY WOODEN DOOR - Fire Door Tested in accordance to IS: 3614 Part 2. Providing 60 min Fire rated doors system duly tested for 3 criteria - Integrity, Insulation and Stability Criteria as per the IS: 3614 Part 2 and BS: 476 part 22 at National Test House, Govt of India laborator and/or with Central Building Research Institute, Govt of India undertaking with standard heating conditions as specified in IS:3614 Part II 1992 and BS: 476 part 20 & 22 1987 to achieve the required integrity, insulation and stability (i.e. to restrict the heat radiation, temperature rise on the non fire side to the maximum of 140° C above the ambient temperature on the exposed surface of the shutter. The fire doors are tested with NCBN technology ("Non Combustible by Nature"). with prior approval of concerned Superitending Engineer. a) Door Frame: Supplying frames for Fire resistant door shutters 1st class Malaysian Hardwood Frame densified (810 Kilogram/cum) and pressure treated with fire retardant chemicals in vacuum impregnation vessel under 160 psi pressure as per IS:401and kiln seasoned to moisture below 15% as per IS:1141 of section 120 X 60 mm spray quoted with 2 coats of intumescent paint of minimum 200 micron, with single row of Brush- Type ASTROFLAME intumescent strip of size 10mm x 4mm affixed in the slit of the Frame for fire and smoke sealing, etc. complete. a] Ground Floor

30

-

-

... More
b] First Floor

15

-

-

... More
c] Second Floor

15

-

-

... More
d] Third Floor

30

-

-

... More
e] Fourth Floor

15

-

-

... More
f] Fifth Floor

15

-

-

... More
b)Shutter : Providing of 65mm thick asbestos free composite - 3 criteria - fire, heat and smoke check Accoustic Door Shutter with flame guard of 120 minutes IS3614 part -II comprising of 2x9mm Calcium Silicate boards, Chemical treated internal timber with Fire retardant chemicals in pressure impregnation vessels under 160 PSI pressure as per IS:401and kiln seasoned to moisture below 15% as per IS:1141 frame work of 100x32 mm with 32mm thick infill of ceramic fiber (density 128Kilograms/CMT), vermaculite mix faced with 6mm Fire retardant High Density ply, internally lipped with hardwood beading, and pasted in Hydraulic Press under 50 tonnes pressure, spray quoted with 2 coats of In tumescent paint of minimum 200 micron, and with 1 row of Brush- Type Astroflame® intumescent strip (imported) of size 10mmx4mm concealed for fire and smoke sealing in the grooves in the shutter on all edges except bottom, without any external lipping. a] Ground Floor

18

-

-

... More
b] First Floor

9

-

-

... More
c] Second Floor

9

-

-

... More
d] Third Floor

18

-

-

... More
e] Fourth Floor

9

-

-

... More
f] Fifth Floor

9

-

-

... More
Providing and fixing in position, Double shuttered aluminium extruded powder coated openable door of specified size with aluminium door frame of powder coated section 101.60 x 44.75mm , 3.18 mm thick and shutter comprising of powder coated section having bottom and lock rail of size 150 mm x 44.5 mm x 3.00 mm thick top rails 47.62 x 44.45 mm x 3.00 mm thick , vertical style 47.62 x 44.45 mm, 3.00 mm thick and for shutter plain glass panes 5 mm thick for top panels and 12mm thick both side laminated phenol bonded particle board panels for bottom panels etc. , I.S.I. mark , heavy duty, Hydraulic floor spring of 150Kilogramcapacity , having heavy duty concealed lock, necessary beading, glazing clips, PVC gaskets, 250mm length aluminium tower bolts, 150mm dia. pad handle, etc. as per detailed design and drawing or as directed by engineer in charge including all materials , labours, and equipment etc.complete a] Ground Floor

40.8

-

-

... More
b] First Floor

10.8

-

-

... More
c] Second Floor

51.9

-

-

... More
Providing and fixing in position U.P.V.C.(Unplasticized Poly Vinyl Chloride) having multi- chambered outer frame section (73 x 50)mm with an outer wall thickness of 2mm & steel reinforcement, multi-chambered slider frame (73x 60) mm with steel reinforcement, multi- chambered slider sash (46x 82) mm with steel reinforcement designed to give optimum strength, 5 mm thick toughened double glass with 12 mm spacer of good quality including alluminium track, Inter-locking profile, coextruded beadings, EPDM gaskets,silicon sealent,sliding handle, fixtures and fastenings (couplings, hinges) including with all required screws and nuts with all necessary U.P.V.C. sections as per the detailed drawing and as directed by Engineer-In-Charge etc. complete. a] Ground Floor

183.96

-

-

... More
b] First Floor

238.14

-

-

... More
c] Second Floor

191.21

-

-

... More
d] Third Floor

183.02

-

-

... More
e] Fourth Floor

184.86

-

-

... More
f] Fifth Floor

156.83

-

-

... More
Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 mm x 1.22 mm box type, 5 mm thick sheet glass louvers, of approved quality etc. complete. a] Ground Floor

20.88

-

-

... More
b] First Floor

18.72

-

-

... More
c] Second Floor

22.77

-

-

... More
d] Third Floor

23.94

-

-

... More
e] Fourth Floor

20.75

-

-

... More
f] Fifth Floor

11.79

-

-

... More
Providing & fixing of Casement fixed window of approved make with DGU. The extruded aluminium sections of Alloy 6063 tolerances confirming to DIN standard from approved raw material V2 / V4 as directed by Engineer in charge. a] Ground Floor

134.4

-

-

... More
c] Second Floor

73.08

-

-

... More
d] Third Floor

73.08

-

-

... More
e] Fourth Floor

73.08

-

-

... More
f] Fifth Floor

73.08

-

-

... More
Providing and Fixing mat finish stainless steel (of 302 grade ) railing with top pipe of 50 mm dia. and vertical pipe of 38 mm dia at 0.60 m c/c or as required and horizontal pipes of 25 mm dia in three rows, all pipes of 2 mm thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 mm dia above newel post of 75 mm diameter etc. complete (Prior approval of sample and brand by Ex.Engineer is necessary before use) a] Ground Floor

105

-

-

... More
b] First Floor

42.4

-

-

... More
c] Second Floor

42.4

-

-

... More
d] Third Floor

42.4

-

-

... More
e] Fourth Floor

42.4

-

-

... More
f] Fifth Floor

52

-

-

... More
Providing and fixing 900mm high S.S.304 Grade Stainless steel railing with 40mm diameter and 1.5mm thick at top, 40mm diameter and 1.5mm thick vertical supports spaced at 1.5m center to center and 8mm thick toughened glass including fabricating ,fixtures, errecting , necessary welding , grinding , finishing, buffing to stainless steel pipe etc. complete a] Ground Floor

76

-

-

... More
b] First Floor

103.4

-

-

... More
c] Second Floor

72.4

-

-

... More
d] Third Floor

72.4

-

-

... More
e] Fourth Floor

137.8

-

-

... More
f] Fifth Floor

153.8

-

-

... More
Providing and applying interior wall finish luster of approved make on internal wall surface as detailed below Scrapping the surface with emery paper and wipe clean wall primer with brush with mineral turpentine with brush 8 to 10% and oil 15 to 20% with roller and allowing to dry for a period 6 to 8 hours. wall putty with appropriate proportion of water allowing to dry for period 4 to 6 hours. Scrapping with Emery paper 180 and wipe clean. Applyingwall primer with brush with mineral turpentine 8 to 10% and oil 15 to 20% with roller Scrapping Emery paper 320 and wipe clean, interior wall finish luster 1st coat with brush/rubber/spray with mineral turpentine 7 to 9% and Oil with roller 19 to 21% After 8 hours of activity Applying 2nd coat or wall finish Lustre with mineral turpentine 7 to 9 % with brush and Oil with roller 19 to 21% after allowing dry for the period of 6 to 8 hours activity. (With prior approval of S.E.) a] Ground Floor

13681.78

-

-

... More
b] First Floor

8118.69

-

-

... More
c] Second Floor

7330.82

-

-

... More
d] Third Floor

7658.69

-

-

... More
e] Fourth Floor

6408.19

-

-

... More
f] Fifth Floor

6199.43

-

-

... More
Providing and applying two coats of exterior acraylic emulsion paint confirming to corresponding I.S. of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface, applying primer coat ,scaffolding if necessary , and watering the surface for two days etc complete. a] Ground Floor

7994.92

-

-

... More
b] First Floor

2063.38

-

-

... More
c] Second Floor

1960.21

-

-

... More
d] Third Floor

1690.8

-

-

... More
e] Fourth Floor

1685.17

-

-

... More
f] Fifth Floor

3017.81

-

-

... More
Providing soak pit of size 120cm x 120cm x 120cm including excavating and filling with brick-bats.

2

-

-

... More
Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates etc. as per detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting fixing in position, Making riveted/ bolted/ welded connection and one coat of anticorrosive paint and over it 2 coats of oil painting approved quality and shade etc. complete. f] Fifth Floor

2.45

-

-

... More
Supply and Installation of Dpi Flux translucent roof with standing seam multicell polycarbonate panel system. The system with complete assembly of co extruded UV protected multicell panels incorporated into a complete system. Co-extruded UV protected polycarbonate panel system of min 22 mm thick of 1200mm (min.) width with angular daylighting concept. Panels shall have minimum seven layers in a truss bridge design for higher flexibility & strength. Panels with opaque and translucent clear combination as per required lux level and design requirements with all fixing accessories to ensure best performance for wind uplift, vibration, oil canning and visual appearance. Panels shall have an additional IR Blocking features for enhance thermal comfort. Panels shall be manufactured with vertical standing seam at both sides of the panel. Panels shall be fixed on Purlin with snap on connectors with double tooth grip lock locking mechanism and will be secured on MS structure (will be paid Separately) with a continuous aluminium I Beam holding the base of the standing seam along the length of the panel & fixed with purlin with self-drilling hex head screws offering best stability with a pull-out load of min. 21000N (21KN) tested as per ISO 6892:1998 and IS 1608: 2005., as per design requirement. Panels must satisfy Dart drop impact test as per IS 14443-97 shall show no sign of breakage on Polycarbonate sheets which have been exposed to UV for a min. of 500 Hours as per ASTM G 155. Panels shall not have Yellowness Index as per ASTM D 1925 of 15 units when tested on a sample exposed to UV for 500 Hours as per ASTM G 155. U value shall not be more than 1.9 W/m2K as per EN ISO 10077-2:2018. Panel shall be with additional End cap/Aluminium U/F profile/ Glazing Bar for ends as required. Panel shall be fixed over MS structural steel/MS purlin (paid separately) conforming to the detail technical specifications as per approved architectural drawings. Trained and factory authorized labour with supervision to complete the entire panel installation as per drawing & direction of the engineer in charge. Colour: As per approval The 22mm thick panels shall be used for a roofing height of upto 55 mtrs. f] Fifth Floor

64

-

-

... More
Providing structural steel work in hollow section of various thickness and sizes in square, rectanular and round shape from 25mm to 450mm section as per IS 4923 YST 310 Grade produced from iron ore and blast furnace route etc. as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted/bolted/ welded connections and painting complete. a] Ground Floor

3.02

-

-

... More
b] First Floor

9.41

-

-

... More
c] Second Floor

7.39

-

-

... More
d] Third Floor

7.39

-

-

... More
e] Fourth Floor

3.53

-

-

... More
f] Fifth Floor

3.53

-

-

... More
Providing and fixing 90 cm x 60 cm Granite plate engraving 10 cm. Height letter, figures including painting the lefters/figures with approved colour and shade complete

2

-

-

... More
Providing and fixing board displaying information, such as 'Name of work, Tender cost, Name of Contractor, Work completion and liability period etc', having rectangular shape of 1.20m x 0.90m size made out 18 gauge (1.25mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols etc. with approved colour shade paint complete, on M.S.angle of size 35 x 35 x 3 mm frame with properly cross braced M.S. angles of size 35mmx35mmx3mm duly painted including Two M.S. angle iron posts of size 65 mm x 65 mm x 6 mm, 3.65 m long painted with alternate black and white bands of 25 cm width including all fixtures etc.and fixing the boards in 1:4:8 concrete block of size 60 cm x 60 cm x 75 cm including, excavation, refilling, transportation, and labour etc complete

1

-

-

... More
Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.

500

-

-

... More
Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.

1500

-

-

... More
Providing and fixing on walls /ceiling/ floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.

500

-

-

... More
Providing and laying in trenches 50mm dai. CPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.

500

-

-

... More
Providing and fixing screw down for 40 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete.

50

-

-

... More
Providing and fixing screw down for 25 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete.

20

-

-

... More
Providing and fixing Orissa Pan of size 580x445x260 mm with approved make flush valve including trap, C.I. soil and vent pipe upto outside face of wall including 100mm dia. C.I. plug, bend and necessary pipe connection, etc complete. As directed by Engineer in charge. a] Ground Floor

13

-

-

... More
b] First Floor

16

-

-

... More
c] Second Floor

16

-

-

... More
d] Third Floor

16

-

-

... More
e] Fourth Floor

18

-

-

... More
f] Fifth Floor

10

-

-

... More
Providing and fixing white european type wall-hung, Size 360mm x 360mm x 575 mm with flush valve having flow rate up to 6.0 Litr/Minute of Jaquar/Cera/Hindware /Perryware or equivalent make including PVC soil pipe, vent pipe upto outside face of wall, 100mm dia PVC plug bend inlet pipe all fittings,cutting & making good walls, floors etc as directed by Engineer in charge.( Make shall conform to manufacturer's Green product and shall got approved from the Engineer In Charge.) a] Ground Floor

24

-

-

... More
b] First Floor

21

-

-

... More
c] Second Floor

17

-

-

... More
d] Third Floor

19

-

-

... More
e] Fourth Floor

15

-

-

... More
f] Fifth Floor

16

-

-

... More
Providing and fixing wall-hung white wash basin of size 470x575x190mm of approved make half pedestal, pillar cock, C.P.Angular stop cock, long thread continental including S.S. bottle trap of having necessary pipe connections up to the outside face of the wall.etc complete. a] Ground Floor

16

-

-

... More
b] First Floor

17

-

-

... More
c] Second Floor

11

-

-

... More
d] Third Floor

14

-

-

... More
e] Fourth Floor

12

-

-

... More
f] Fifth Floor

8

-

-

... More
Providing and fixing Oval Type Under Counter Wash Hand Basin of 420 x 590 x 195mm size with pillar cock, C.P.Angular stop cock, long thread of approved make continental including SS bottle trap of necessary pipe connection up to the outside face of the wall, having Telephonic Black / Colour Granite of 180 mm thick fixed on Black Kadappa Framework, etc. Complete as directed by Engineer in charge. a] Ground Floor

9

-

-

... More
b] First Floor

9

-

-

... More
c] Second Floor

9

-

-

... More
d] Third Floor

9

-

-

... More
e] Fourth Floor

9

-

-

... More
f] Fifth Floor

9

-

-

... More
Providing and fixing C.P. 2 Way BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge.

133

-

-

... More
Providing and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge.

89

-

-

... More
Providing and fixing wall mixer with overhead shower,shower arm,hand shower with wall bracket having flow rate up to 12 liters/minutes of Jaquar/Cera/Hindware /Perryware or equivalent make including all necessary pipes,fittings etc.complete as directed by Engineer In Charge.( Make shall conform to manufacturer's Green product and shall got approved from the Engineer In Charge.)

50

-

-

... More
Providing and fixing sink cock with regular swinging spout (Wall / floor Mounted Model) with wall flange having flow rate up to 6.0 Litr/Minute of Jaquar/Cera/Hindware /Perryware or equivalent make incluidng other necessary fitting, etc. complete as directed by Engineer in charge.( Make shall conform to manufacturer's Green product and shall got approved from the Engineer In Charge.)

50

-

-

... More
Providing and Fixing half turn 25 mm dia gun metal flushing cock including all accessories etc. complete.

89

-

-

... More
Providing and fixing 450mm x 550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete.

2

-

-

... More
Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140Kilogramwith frame etc complete.

30

-

-

... More
Providing and constructing Brick Masonry Inspection Chamber 90cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W.pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140Kilogramwith frame etc complete.

50

-

-

... More
Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe andwith necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete.

2500

-

-

... More
Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and Nos ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete.

1500

-

-

... More
Providing and fixing H.D.P container one piece moulded water tank made out of low density polythyler and built corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity above 1000 to 20,000 litres f] Fifth Floor

20000

-

-

... More
Providing and fixing 10 cm PVC nahani trap with grating etc. complete.

250

-

-

... More
Providing , laying and fixing ,jointing Eco- drain 160 mm SN 4 Nu- Drain Upvc pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees , coupler, etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated materialetc. complete.

500

-

-

... More
Providing and fixing in position UPVC ultra violet stabilized 110 mm outer diameter cowl dome confirming to I.S.-4985 including making joints with solvent cement etc. complete

100

-

-

... More
RWH - Recharge Pit Providing and constructing recharge pit of 2.0m deep and 1.0m dia of pre-cast RCC rings with 6.5" dia x 25m deep borewell at the floor of recharge pit including installation of combination of solid/perforated PVC casing pipe wrapped around with netlon mesh including 300mm thick sidefilling around outside of RCC rings (annular space) with 40mm size boulders including filling of recharge pit up to 0.5m depth with 25-75mm clean washed gravels from bottom up followed by 0.5m depth of 10- 25mm of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) media layer including covering with RCC slab, manhole frame & cover, PVC rungs, PVC end- caps, fittings etc. including arrangement for inlet & outlet pipe excavation & backfilling as shown in the drawing.The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge.

5

-

-

... More
Boring/drilling bore well of 300mm dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machinery required for the job, all complete as per direction of Engineer in charge, upto 90m depth below ground level.

80

-

-

... More
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well-casing pipe of 150mm dia, conforming to IS:12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per the direction of Engineer in charge.

12

-

-

... More
Providing and supplying in standard length polytyhelene pipes including all local & central taxex, octri, inspection charges, transportation to stores etc. complete. (6 Kg/sqcm - 63 mm dia )

80

-

-

... More
Lower Laying, jointing in standard length polythelene pipes (6 kg/sqcm - 63 mm dia ) including all labour cost transportation etc. complete.

80

-

-

... More
Removing rich mix cement concrete including stacking the spoils as directed with all leads, lifts etc, complete.

453.43

-

-

... More
Dismantling brick masonry in lime or cement mortar and stacking the materils as directed with all leads, lifts etc.

2215.3

-

-

... More
Dismantling stone masonry in lime or cement mortar including stacking the materils as directed with all leads, lifts etc.

404.23

-

-

... More
Removing lime or lean cement concrete including stacking the spoils as directed with all leads, lifts etc, complete.

263.82

-

-

... More
Removing doors and windows with frames and stacking the materials as directed with all leads, lifts etc. complete.

356

-

-

... More
Removing ventilators and small windows with frame and stacking the materials with all leads, lifts etc. complete.

107

-

-

... More
Disposal of building rubbish/ malba /Similar unserviceable dismantled or waste materal by engineer in charge.

3336.78

-

-

... More
(Electrical work) PVC Conduit 25 mm (1.1.9) Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.

1564

-

-

... More
PVC Conduit 25 mm (1.1.10) Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.

4257

-

-

... More
PVC Conduit 32 mm (1.1.11) Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.

220

-

-

... More
PVC Conduit 32 mm (1.1.12) Supplying and laying HMS PVC conduit FRLS grade 32mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.

1113

-

-

... More
PVC Trunking 25 mm (1.2.7) Supplying and erecting PVC trunking (PVC casing-n-capping) of size 25 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.

15

-

-

... More
PVC Trunking 32 mm (1.2.8) Supplying and erecting PVC trunking (PVC casing-n-capping) of size 32 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.

725

-

-

... More
Mains 1x1.5 sq.mm (1.3.1) Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW

5742

-

-

... More
Mains 2x1.5 sq.mm (1.3.1) Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW

5742

-

-

... More
Mains 1x2.5 sq.mm (1.3.2) Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW

3546

-

-

... More
Mains 2x2.5 sq.mm (1.3.2) Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW

3546

-

-

... More
Mains 1x4 sq.mm (1.3.3) Supplying and erecting mains with 1x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW

3600

-

-

... More
Mains 2x4 sq.mm (1.3.3) Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW

2400

-

-

... More
Mains 4x4 sq.mm (1.3.3) Supplying and erecting mains with 4x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW

1200

-

-

... More
Mains 1x6 sq.mm (1.3.4) Supplying and erecting mains with 1x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW

550

-

-

... More
Mains 4x6 sq.mm (1.3.4) Supplying and erecting mains with 4x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW

550

-

-

... More
Mains 1x10 sq.mm (1.3.5) Supplying and erecting mains with 1x10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW

550

-

-

... More
Mains 4x10 sq.mm (1.3.5) Supplying and erecting mains with 4x10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW

550

-

-

... More
Modular Switch 6 A (1.6.1) Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.

679

-

-

... More
Modular Switch 16 A (1.6.2) Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete.

591

-

-

... More
Modular Socket 6A (1.6.10) Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.

679

-

-

... More
Modular Socket 16A (1.6.11) Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.

591

-

-

... More
Telephone Socket (1.6.15) Supplying and erecting modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connections complete.

5

-

-

... More
Modular Step Regulator (1.6.23) Supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete.

964

-

-

... More
Modular 1 way Box (1.6.26) Supplying and erecting PVC Surface modular switch box with double mounting plate for 1 module complete duly erected.

5

-

-

... More
Modular 2 way Box (1.6.27) Supplying and erecting PVC Surface modular switch box with double mounting plate for 2 module duly erected.

5

-

-

... More
Modular 3 way Box (1.6.28) Supplying and erecting PVC Surface modular switch box with double mounting plate for 3 module duly erected.

5

-

-

... More
Modular 6 way Box (1.6.30) Supplying and erecting PVC Surface modular switch box with double mounting plate for 6 module duly erected.

5

-

-

... More
Modular 12 way Box (1.6.32) Supplying and erecting PVC Surface modular switch box with double mounting plate for 12 module duly erected.

5

-

-

... More
1 Module (1.6.34) Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.

5

-

-

... More
2 Module (1.6.35) Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.

22

-

-

... More
3 Module (1.6.36) Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.

13

-

-

... More
Double Mounting Plate (1.6.38) Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.

444

-

-

... More
Modular Switch Box 12 Module (1.6.40) Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.

117

-

-

... More
A.C. Starter 25 A (1.6.43) Supplying and erecting 16 / 20 / 25 A starter (modular range) 2 module for AC unit on provided box complete & duly concealed with necessary material and connected.

9

-

-

... More
SPMCB (1.6.44) Supplying and erecting 6 to 32 A, 10kA, SPMCB suitable to fix in 1 module of modular switch in provided box complete & duly concealed with necessary material and connected.

85

-

-

... More
Point Wiring (1.7.5) Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/CW

2100

-

-

... More
Point Wiring (1.7.6) Point wiring for ceiling fan concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/CW

746

-

-

... More
Lt./Bell Hybrid Point (1.7.15) Point wiring for light/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/HW

219

-

-

... More
Fan Point (1.7.16) Point wiring for ceiling fan (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/HW

174

-

-

... More
Light Point (1.7.19) Point wiring for light/bell/exhaust fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW

251

-

-

... More
Fan Point (1.7.20) Point wiring for ceiling fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW

2

-

-

... More
Plug on board (1.7.26) Wiring for plug on board with Switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WG-PW/CW

479

-

-

... More
LED down Lighter (2.1.4) Supplying and erecting LED square / circular Max. 14 W down lighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 1500 Lumens, min. efficacy of 110 lumen/W, CRI80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD10%, p.f. 0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.

5

-

-

... More
Down Lighter (2.1.5) Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD10%, p.f. 0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.

28

-

-

... More
Down Lighter (2.1.6) Supplying and erecting LED square / circular Max. 25 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2750 Lumens, min. efficacy of 110 lumen/W, CRI80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD10%, p.f. 0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.

118

-

-

... More
LED Panel Light (2.1.8) Supplying and erecting LED Panel Light(600mm X 600mm) Max. 35 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min 4200 Lumens, min. efficacy of 120 lumen/W, CRI80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD10%, p.f. 0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.

282

-

-

... More
Recess (2.1.13) Making suitable size recess in any type of false ceiling for erection of flush type down lighter and finishing the background to match the original surface upto 20W.

33

-

-

... More
Recess (2.1.14) Making suitable size of recess in any type of false ceiling for erection of flush type LED panel light 600mm x 600mm/1200x300mm and finishing the background to match the original ceiling surface.

282

-

-

... More
LED Fitting (4 Feet) (2.1.18) Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens , min. efficacy of 100 lumen/W, CRI80, CCT upto 6000K, Beam Angle of 110 deg., Ripple5%, THD10%, p.f. 0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty.

810

-

-

... More
LED 20 watt. Tube Fitting (2.1.22) Supplying & erecting inverter LED batten 20W tube light fitting with polycarbonate housing, heat sink, integrated HF electronic driver, Min. 2600 mAh Lithium ion Battery with charging time of 8-10 Hours and backup time of Min. 3 hrs. with minimum 25% of initial Watts having luminous efficacy of 100 lumen/watt, CRI80, CCT of 6500K and THD=20% having useful life of minimum 25000 hrs. with overheating protection with 2 years warranty.

809

-

-

... More
LED Street Light fitting 60 w. (2.4.5) Supplying and erecting integrated LED street light fitting 60W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 6600 Lumens, min. efficacy of 110 lumen/W, CRI70, CCT upto 6500K, THD10%, p.f. 0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2.

12

-

-

... More
Street Light Bracket (2.7.4) Supplying and erecting street light Wall bracket made from 40 mm. dia ‘ G.I. pipe 1.2 m. in total length complete as per specification no. FG-BKT/WB

12

-

-

... More
Eshaust Fan (2.10.14) Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 225mm. 1400 RPM rust proof body & blades, wire mesh, duly erected, complete.

192

-

-

... More
B.L.D.C. Ceiling fan (2.10.22) Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of 28W having service ratio (CMM/W) of Min. 8 , PF0.9, THD10% without IR remote control/compatible speed regulator, Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF (Without Remote )

958

-

-

... More
Fan Hook (2.11.4) Supplying and erecting fan hook of 10 mm. M.S. round bar grouted in RCC slab with making the site as original.

958

-

-

... More
Down Rod (2.11.6) Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire.

958

-

-

... More
Split Type A.C. (3.2.11) Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.3TR to 1.6TR capacity having ISEER minimum 5.00 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. APAC/ WAC

9

-

-

... More
Copper Pipe (3.2.27) Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 16mm complete.

36

-

-

... More
Water Cooler 150 Litres (3.3.10) Supplying, erecting, testing and commissioning self contained water cooler 230/250V 50Hz nominal cooling capacity of 150 litres per hour and storage capacity 150 litres with partially stainless steel body as per specification no. AP-WCR/WC

13

-

-

... More
Water Purifier (3.5.1) Supplying and erecting ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps with output of purified water minimum 0.33 litre/min with activated carbon filter and softener operating on 230V, single phase A.C. supply with UV fail & filter change indication system .(for TDS more than 200)

13

-

-

... More
UPS 10 KVA (3.7.7) Supplying, erecting, testing and commissioning of 10kVA capacity online pure sine wave, with backup time of ....... hrs. PWM & IGBT based UPS with 0.9 to unity output pf, 3 phase input & 3 phase output complete with all protections as per specification no. AP-UPS

5

-

-

... More
SMF Battery (3.8.11) Supplying and erecting 12 V/65Ah SMF battery with battery terminal wire, duly charged complete with 24 months warranty complete

100

-

-

... More
SPMCB 6 A to 32 A (5.3.2) Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

672

-

-

... More
SPMCB 6 A to 32 A (5.3.3) Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

672

-

-

... More
TPMCB 6 A to 32 A (5.3.10) Supplying, erecting & marking TPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

56

-

-

... More
TPMCB 40 A to 63 A (5.3.11) Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

56

-

-

... More
TPNDB (5.4.3) Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 12 ways /phase (36 poles), with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB

112

-

-

... More
TPNDB 8 Way (5.4.16) Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/4 pole MCCB as incomer & outgoing SP MCB (24 poles) or TP MCB of 8 ways (24 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1

14

-

-

... More
MCCB 04 Pole (5.5.1) Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB

30

-

-

... More
MCCb 04 Pole (5.5.4) Providing & erecting 4 Pole MCCB 415V, 400A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure /panel as per specification no. SW-SWR/MCCB

2

-

-

... More
RCCB 4 Pole (5.6.5) upplying, erecting & commissioning 4 pole RCCB 40A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB

56

-

-

... More
RCCB 4 Pole (5.6.6) Supplying, erecting & commissioning 4 pole RCCB 63A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB

56

-

-

... More
MCCB Panel Board (5.7.8) Providing & erecting floor/wall mounting, MCCB panel board, with door, suitable for four pole incoming 400 A, 6 ways four pole outgoing, up to 100 A MCCBs on iron frame, as per specification no SW-SWR/MCCBPB. (Excluding MCCBs)

2

-

-

... More
Cable Alleys (5.7.14) Providing & erecting incoming and outgoing cable alleys suitable for MCCB panel board with door, 250A incoming and 8 way outgoing or 400A incoming and 6 way outgoing made from CRCA sheet 1.6 mm thick duly powder coated and having vertical insulated partition for shielding between the shared face of cableway and DB.

2

-

-

... More
Prewired Meter (5.7.17) Providing & erecting prewired meter module suitable for MCCB panel board with CTs and emfs VIF meter.

2

-

-

... More
MCCB Enclosure (5.11.17) Supplying and erecting SS enclosure for MCCB suitable for up to 100A MCCB.

1

-

-

... More
Iron Work (6.1.19) Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.

60

-

-

... More
G.I. Pipe 150 mm (7.6.5) Supplying & laying (including excavation) reinforced cement concrete pipe of IS 458:2003 NP-2 class of 150 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.

60

-

-

... More
Plate Earthing (9.1.1) Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP

4

-

-

... More
Lan, Telephone and C.C.T.V. System Telephone Socket (1.6.15) Supplying and erecting modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connections complete.

50

-

-

... More
2 Pair Telephone Cable (1.8.1) Supplying & erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW

1120

-

-

... More
10 Pair Telephone Cable (1.8.13) Supplying & erecting 10 pair, 0.5 mm dia. jelly filled armoured telephone copper cable with poly-al laminate moisture barrier, polythene sheathed, G.S.Tape armoured polythene jacketed having laid in provided trench as per specification No. WG-TW

250

-

-

... More
10 M HDMI Cable (1.8.23) Supplying and erecting 10m HDMI cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete.

1

-

-

... More
MDF Box (1.9.1) Supplying, erecting & commissioning MDF Box 50x50 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW

1

-

-

... More
10 Pairs Junction Box (1.9.11) Supplying, erecting & commissioning 10 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TW

5

-

-

... More
10 Pairs Connection (1.9.18) Supplying, erecting & commissioning 10 pair module for connection & disconnection of telephone cable as per specification no. WG-TW

5

-

-

... More
(1.9.26) Supplying and installing, testing & commissioning of digital (hybrid) type EPABX of 6 x 32 extensions suitable upto 96 extensions complete.

1

-

-

... More
Telephone Instrument (1.9.28) Supplying, installing, testing & commissioning push button telephone instrument desk top unit as per specification complete

50

-

-

... More
Telephone Instrument (1.9.29) Supplying, installing, testing & commissioning push button telephone instrument desk top/wall mount with caller ID & Speaker unit as per specification complete.

1

-

-

... More
Cat-6 Cable (1.10.1) Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC

2900

-

-

... More
Patch cord (1.10.16) Supplying and fixing 1 m UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC

58

-

-

... More
24 Ports Switch (1.11.4) Supplying, fixing, and configuring 24 ports with 4 (SFP+) port, ethernet managed switch with web view/CLI, 6KV surge protection on ethernet port and console port for management in provided rack as per specification no. WG-NWC/GBS

6

-

-

... More
Tool-Less (1.12.4) Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP

6

-

-

... More
6 U Wall Mount Rack (1.12.17) Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x600x367 mm) as per specification No. WG-NAS/RAK

7

-

-

... More
RJ-45 (1.12.1) Supplying, installing and testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC.

116

-

-

... More
Tool-Less (1.12.2) Supplying and fixing tool-less IO (Ethernet) flush/surface type in provided modular box as per specification no. WG-NAS/IO

58

-

-

... More
UPS 02 KVA (3.7.2) Supplying, erecting, testing and commissioning of 2kVA capacity online pure sine wave, with backup time of ....... hrs. PWM & IGBT based UPS with 0.8 to unity output pf, single phase input & 1 phase output complete with all protections as per specification no. AP-UPS

1

-

-

... More
SMF Battery (3.8.11) Supplying and erecting 12 V/65Ah SMF battery with battery terminal wire, duly charged complete with 24 months warranty complete

8

-

-

... More
(Non C.S.R.) Supplying & erecting of High definition 4/5 Megapixel IP IR Bullet Camera with following features Image Sensor : minimum 1/2.8" Progressive Scan CMOS, Video Resolution : minimum 2592 x 1520 Video Compression : H.264, H.265 or higher, at least Three individually configurable stream, Frame rate : minimum 25 fps at all resolutions, WDR : minimum 120 dB Wide Dynamic Range, ONVIF profile conformant, minimum IR distance : 50m, Lens Type : 2.8/4/6 mm Lens, fixed focal, Field of View : 2.8 mm, horizontal FOV 107°, vertical FOV 57°, diagonal FOV 129° 4 mm, horizontal FOV 86°, vertical FOV 47°, diagonal FOV 102° 6 mm, horizontal FOV 55°, vertical FOV 29°, diagonal FOV 65° Lux sensitivity - minimum 0.2 Lux at color, minimum 0.05 Lux at Black & White, 0.0 Lux (IR) Night Vision Distance minimum IR - 50m. Camera minimum Adjustment Angles - Pan : 350°, Tilt : 72°, Rotate : 350°. Power Supply : Support 12VDC & PoE, IP67, IK10 - Vandal Resistant. Built in micro SD/SDHC/SDXC card slot of minimum 128 GB, Built in microphone. minimum Input/Output - Audio in × 1, Audio Out × 1, Alarm in × 1, Alarm Out × 1. Image Settings : Rotate mode, saturation, brightness, contrast, sharpness, gain, white balance. Image Enhancements : Day/Night-Auto (ICR)/Color/Black & White, 3D Digital Noise Reduction, Automatic White Balance, Automatic Gain Control, Backlight Compensation, Highlight Compensation. Events : Privacy Masking, Motion detection, Scene change detection, Face capture, Video tampering, audio exception detection, Region entrance detection, Region exiting detection. Operating temperature ( -30 to 60° C ) . Security - User account and password protection, HTTPS, IP filter, IEEE 802.1X, digest authentication, user access log, TLS1.2, AES - 256, SSH/Telnet closed, FTP disabled. Protocol - DHCP, UDP, HTTP, HTTPS, NTP, DNS, RTP, RTSP, SMTP, SSL/TLS, TCP/IP, Secure Real-Time Transport Protocol (SRTP), Bonjour, SNMP and Secure shell (SSH) supported protocol. RoHS, WEEE, ISO-14001 and REACH compliant, UL/EN OR equivalent BIS/TECH/STQC or any indian standards as applicable, CE, FCC certified. duly erected in position on wall/ceiling/false ceiling/provided pole (mounting height not more than 5 meter) etc with all accessories etc complete as per specification no. CCTV-CAM

8

-

-

... More
(Non C.S.R.) Supplying & erecting of High definition 4/5 Megapixel IP IR Dome Camera with following features Image Sensor : minimum 1/2.8" Progressive Scan CMOS, Video Resolution : minimum 2592 x 1520 Video Compression : H.264, H.265 or higher, at least Three individually configurable stream, Frame rate : minimum 25 fps at all resolutions, WDR : minimum 120 dB Wide Dynamic Range, ONVIF profile conformant, minimum IR distance : 50m, Lens Type : 2.8/4/6 mm Lens, fixed focal, Field of View : 2.8 mm, horizontal FOV 107°, vertical FOV 57°, diagonal FOV 129° 4 mm, horizontal FOV 86°, vertical FOV 47°, diagonal FOV 102° 6 mm, horizontal FOV 55°, vertical FOV 29°, diagonal FOV 65° Lux sensitivity - minimum 0.2 Lux at color, minimum 0.05 Lux at Black & White, 0.0 Lux (IR) Night Vision Distance minimum IR - 50m. Camera minimum Adjustment Angles - Pan : 350°, Tilt : 72°, Rotate : 350°. Power Supply : Support 12VDC & PoE, IP67, IK10 - Vandal Resistant. Built in micro SD/SDHC/SDXC card slot of minimum 128 GB, Built in microphone. minimum Input/Output - Audio in × 1, Audio Out × 1, Alarm in × 1, Alarm Out × 1. Image Settings : Rotate mode, saturation, brightness, contrast, sharpness, gain, white balance. Image Enhancements : Day/Night-Auto (ICR)/Color/Black & White, 3D Digital Noise Reduction, Automatic White Balance, Automatic Gain Control, Backlight Compensation, Highlight Compensation.

56

-

-

... More
(Non C.S.R.) Supplying, installing, testing & commissioning of 64 Ch. Network Video Recorder (NVR), suitable connect Min. 32 IP Cameras, up to 5 Megapixel Resolution, with HDMI/VGA outputs, provided HDMI output of 4K resolution or VGA output with output up to 1920 × 1080. Support H.265 or higher, H.264, MJPEG, Incoming Bandwidth 250Mbps with minimum 4 SATA Hard Disks, ANR Technology, 4 SATA interfaces for 4 HDDs and capacity of each HDD up to 8TB, minimum 02 USB port, Alarm I/O 16/4, RJ-45 10/100/ 1000 Mbps self-adaptive Ethernet interface, ONVIF conformance, Multiple network monitoring: Web viewer . support protocol TCP/IP, DHCP, DNS, DDNS, NTP, SADP, SMTP, NFS, iSCSI, UPnP™, HTTPS. RoHS, UL, CE, FCC certified. duly erected in provided U Rack with wiring connections, tagging and programming etc. complete as per specification no. CCTV-NVR

1

-

-

... More
(Non C.S.R.) Supplying & erecting 8 TB internal Surveillance HDD suitable for SATA Port of NVR, interface transfer rate 6 GB/S, maximum sustained transfer rate 210 MB/Sec to 213 MB/S. Drive bay supported 08+, Cameras supported up to 64, Cache (MB) 256, Load/Unload Cycle -3000000, Work Load Rating per Year 180TB, MTBF 1000000 Hrs. HTTPS. RoHS, UL, CE certified, duly erected in position in provided NVR as per specification no. CCTV-HDD

10

-

-

... More
(Non C.S.R.) Supplying & erecting 55" professional LED display with 1920 *1080 ( Full HD) Display, suitable for 32/64 channel NVR and following features Brightness: minimum 500 Cd/m2 Contrast Ratio: minimum 1000:1 Viewing angle: 178/178 deg. Response time: maximum 8 ms Inputs: HDMI, VGA, BNC,USB, Audio In, Built-in speakers maximum 10 W, Suitable to operate on 100-240 V 50 Hz AC supply and 24/7 Duty Cycle duly erected on wall or table top with standard accessories like wall mount stand and wiring connections etc. complete as per specifications no. CCTV-MON

2

-

-

... More
Solar Water heater ETC Solar Water Heating System (4.1.9) Supplying, installing, testing and commissioning of ETC solar water heating system without heat exchanger type of 500 LPD capacity with SS water tank of 0.5 mm thickness conforming to IS1239 Part-I :2004 complete as per specification no. ESD-SHWS-ETC

4

-

-

... More
Elastomeric (4.2.13) Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 28 mm for solar water heater/AC system.

120

-

-

... More
Elastomeric (4.2.15) Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 42 mm for solar water heater/AC system.

80

-

-

... More
(4.2.19) Supplying and erecting 25/32 mm (ID/OD) Chlorinated polyvinyl chloride pipe (CPVC), thickness 3.2 mm conforming to IS 15778 (CTS Series) with necessary CPVC fittings and solvent cement for Solar Water Heater System as per specification No. ESD-HWP/CPVC

120

-

-

... More
CPVC Pipe (4.2.20) Supplying and erecting 32/40 mm (ID/OD) Chlorinated polyvinyl chloride pipe (CPVC), thickness 3.8 mm conforming to IS 15778 (CTS Series) with necessary CPVC fittings and solvent cement for Solar Water Heater System as per specification No. ESD-HWP/CPVC

80

-

-

... More
Water Tank (4.8.7) Providing and fixing high-density polyethylene (HDPE) container one piece moulded triple layer water tank made out of high density polyethylene and built corrugated inclusive of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow pipe inclusive of all tanks capacity up to 20000 litres.

2000

-

-

... More
Iron Work (6.1.19) Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.

325

-

-

... More
Sluice Valve (16.6.13) Supplying and erecting 25 mm dia. gun metal sluice valve at position with necessary materials complete.

8

-

-

... More
Sluice Valve (16.6.14) Supplying and erecting 40 mm. dia. gun metal sluice valve at position with necessary materials complete.

8

-

-

... More
Non Return Valve 40 mm Dia (16.6.20) Supplying and erecting non return valve 40 mm dia in position made of gun metal complete.

8

-

-

... More
(Transfrmer, D.g., H.T. Metering Main Panel Street Light) Cable 03 Core Flexible .25 sq.mm. (1.3.15) Supplying and erecting PVC insulated PVC round sheathed 2.5 sq.mm (50 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV

224

-

-

... More
LED Street Light Fitting (2.4.8) Supplying and erecting integrated LED street light fitting 100-110W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 11000 Lumens, min. efficacy of 110 lumen/W, CRI70, CCT upto 6500K, THD10%, p.f. 0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2.

55

-

-

... More
Led Flood Light Fitting (2.4.18) Supplying and erecting integrated LED flood light fitting Max. 195W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 23400 Lumens, min. efficacy of 120 lumen/W, CRI70, CCT upto 6500K, THD10%, p.f. 0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2.

12

-

-

... More
Post Top lantern (2.5.5) Supplying & erecting integral post top lantern fixtures (light house type) suitable upto LED 18 W Lamp consisting of combination of spun aluminium canopy & clear acrylic top cover, cast aluminium pole cap on provided pole/ bracket as per specification no. FG-ODF/PTL

4

-

-

... More
LED Lamp 18 Watt. (2.8.13) Supplying & erecting 18W, 230V integral type LED Lamp suitable for B-22 / E-27 base.

4

-

-

... More
Street Light Control Panel (5.2.5) Supplying & erecting three phase, 415V, street light control panel up to the max load of 6kW, TPN MCB 40A, powder coated CRCA 14 SWG sheet, outdoor type, having IP54,IK10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protection on provided iron frame / CC foundation.

1

-

-

... More
SPMCB 0.5A to 5A, (5.3.1) Supplying, erecting & marking SPMCB 0.5A to 5A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

28

-

-

... More
MCCB 04 Pole (5.5.1) Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB

3

-

-

... More
MCCB 4 Pole (5.5.3) Providing & erecting 4 Pole MCCB 415V, 250A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB

2

-

-

... More
MCCb 04 Pole (5.5.4) Providing & erecting 4 Pole MCCB 415V, 400A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure /panel as per specification no. SW-SWR/MCCB

3

-

-

... More
MCCB 04 Pole (5.5.6) Providing & erecting 3 Pole MCCB, 415V, 800A, rated short-circuit breaking capacity 50 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB

1

-

-

... More
Prewired Meter (5.7.17) Providing & erecting prewired meter module suitable for MCCB panel board with CTs and emfs VIF meter.

1

-

-

... More
Break Switch (5.9.7) Supplying, installing, testing and commissioning 11 kV 630A, indoor type ring main unit with 2 VCB & 2 LBS with internal arc compliance complete erected on provided CC foundation/MS channels/trench, etc., as per specification no SW-HTS / RMU

1

-

-

... More
Bus Bar Support (5.10.26) Supplying & erecting porcelain/epoxy bus bar support complete erected in provided M.S. box for 100A

20

-

-

... More
Bus Bar Support (5.10.27) Supplying & erecting porcelain/epoxy bus bar support complete erected in provided M.S. box for 200/300A

12

-

-

... More
Bus Bar Support (5.10.28) Supplying & erecting porcelain/epoxy bus bar support complete erected in provided M.S. box for 400A

16

-

-

... More
CRCA Sheet (6.1.1) Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete.

224

-

-

... More
(6.1.10) Supplying and erecting hylam sheet/ ebonite 6 mm thick for covering wall entries including cutting, drilling and fixing with nut bolts / screws etc. complete.

0.5

-

-

... More
Iron Work (6.1.19) Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.

195

-

-

... More
(6.2.11) Supplying and erecting of any size electrolyte aluminium patti or bar in bus bar chamber / in panel or any other purpose, 500 V with require capacity 99.9% aluminium purity with E91E Grade as per IS 5082 & Current Density 0.8 A per sq. mm. with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as per specification no. BCP-BB

10

-

-

... More
11 K.V. H.T. Cubical (6.4.1) Supplying, erecting, testing and commissioning 11KV HT metering cubical (compact / vertical type) approved by MSEDCL / licensee fabricated with 2 mm (14 SWG) M.S. sheets with supporting angle, painted with powder coating / epoxy paint of required shade, copper bus bar size 25 x 6 mm, heavy duty mechanical lock, with counter meter for measuring no of times the opening of meter door, top side cover (CT, PT cover) interlock with meter door, epoxy casted 3 nos. CT having required ratio between 10/5A to 50/5A, VA10 or 15, Class 0.5S, epoxy casted 3 nos. PT having ratio 11000/V3/110/V3 VA 50, Class 0.5 suitable for provided trivector meter, and provision for incoming and outgoing cables complete duly tested by licensee with necessary test certificates and erected on provided plinth/ cc foundation.

1

-

-

... More
APFC Panel (6.7.9) Supplying and erecting 200 kVAr, 440 V 3 phase, 50 Hz., Contactor Logic & Intelligent Relay micro APFC passive filter panel, consisting of suitable steps of APP/MPP type capacitor units with Detuned (harmonic filter) reactors of suitable rating , APFC panel shall be compliance to IEC 61439 and power quality IEC 61921 standard as per specification no CP-ED/APFC

1

-

-

... More
Arm.cable 1100 V. 3½ core 300 sq. mm. (7.1.24) Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 300 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

150

-

-

... More
Arm.cable 1100 V. 3½ core 400 sq. mm. (7.1.25) Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½core 400 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

171

-

-

... More
FR XLPE 4x4 sq.mm. (7.1.26) Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

90

-

-

... More
FR XLPE 4x6 sq.mm. (7.1.27) Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

732

-

-

... More
Cable 3 x 120 Sq. mm. (7.3.3) Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 11 kV(E), 3 x 120 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT

120

-

-

... More
Termination Kits (7.5.2) Providing and erecting Heat shrinkable indoor termination kit for 11 kV ( E ) XLPE HT cable 3x120 to 185 sq. mm. with necessary material as per specification no. CB-JT/HT

4

-

-

... More
Out Door Termination Kit (7.5.6) Providing and erecting Heat shrinkable outdoor termination kit for 11 kV ( E ) XLPE HT cable 3x120 to 185 sq. mm. with necessary material as per specification no. CB-JT/HT

4

-

-

... More
G.I. Pipe 40 mm (7.6.2) Supplying & erecting G.I. pipe ‘A’ class 40 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE

6

-

-

... More
G.I. Pipe 50 mm (7.6.3) Supplying & erecting G.I. pipe ‘A’ class 50 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE

24

-

-

... More
G.I. Pipe 75 mm (7.6.4) Supplying & erecting G.I. pipe ‘A’ class 75 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE

15

-

-

... More
G.I. Pipe 150 mm (7.6.5) Supplying & laying (including excavation) reinforced cement concrete pipe of IS 458:2003 NP-2 class of 150 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.

80

-

-

... More
D.W.C. Pipe 50 mm (7.6.9) Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.

700

-

-

... More
D.W.C. Pipe 146 mm (7.6.13) Supplying and laying (including excavation of suitable width & depth up to 90 cm) 146 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.

100

-

-

... More
FRP Box (7.8.9) Supplying & erecting FRP box of size 250mm x 200mm x 100 mm, 2.7 mm thick complete on pole/wall as per specification No. CB-SB

4

-

-

... More
Girder Pole (8.1.13) Supplying and erecting rolled steel joist (girder) pole 100 x 116 mm (23 kg/m) with base plate in provided foundation as per specification no. OH-PL/RSJ [11 x 4 = 44 Mtr.]

44

-

-

... More
High-Mast 12.5 Mtr. (8.2.1) Supplying and erecting 12.5 m (clear height) motorized high-mast (Top -150mm, Bottom- 360mm) hot dipped galvanized material with average minimum thickness 65 micron, made from high tensile structure grade steel as per BSEN - 10025 S 355/E350 & 3mm thickness, with base plate 25 mm thick x OD 520 mm grade as per IS-2062, pole made in single section & submerge arc welded, with lowering & raising motorized unit, wire rope stainless steel 316 grade 2 nos., 7x19 construction 5mm, SG-DG U clamps, double drum with assembly 250 kg, 5x2.5 Sq.mm. flexible copper cable with lantern carriage assembly suitable for max. 12 nos. luminaires and its control gear box, lightning arrestor, arrangement for fixing aviation light, high-mast with serial number, factory inspection report/test report of high-mast should be provided as per specifications on provided foundation J type stud/bolts with necessary accessories complete as per specification no. OH-PL/HM (excluding luminaries)

2

-

-

... More
Octagonal Pole 08 Mtr (8.2.15) Providing & erecting 8 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 135 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL

28

-

-

... More
Sword Type Bracket (8.2.21) Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT

1

-

-

... More
Sword Type Double Bracket (8.2.22) Providing and erecting galvanised 1000mm double arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT

27

-

-

... More
Feeder Pillar (8.2.23) Supplying and erecting outdoor stand mounted feeder pillar for high-mast of the same manufacturer with 32A TPN MCB incomer, 24hr astronomical time switch with minimum 5 years battery backup, IP 54 and IK10 protection, 25 A TP contactor for automatic switching of luminaires, 2 no. 9A contactors and raise/lower push button, and provision for termination of adequate size of incoming and outgoing cables complete erected in min. 14 SWG CRCA sheet box with supporting angles, self lock, gasket and slanting top erected on CC foundation complete.

2

-

-

... More
(8.3.11) Supplying & erecting 100 x 50 x 6 mm with 4.7 mm thick web and 7.5 mm thick flange channel iron cross arm of suitable length for 2.4 m wide DP structure and erecting on DP with 50x6mm clamp complete as per specification no. OH-PL/BKT

7

-

-

... More
ACSR Conductor (8.4.7) Supplying and erecting ACSR conductor of size 6/1-2.59 mm complete. (Weasel) (127.7 kg/km) as per specification No. OH-CON/ACSR

0.1

-

-

... More
Disc Insulator (8.5.6) Supplying and erecting porcelain disc type insulator 45KN with necessary hardware suitable for 11kV line, complete as per specification no. OH-INS/DI

6

-

-

... More
Pin Insulator (8.5.9) Supplying and erecting porcelain pin type insulator with GI pin suitable for 11kV line, complete as per specification no. OH-INS/PN

6

-

-

... More
Lightening Arrester (8.5.15) Supplying and erecting distribution class, 11 kV thyrite type lightening arrester with nut bolts, on provided MS channel as per specification no. OH-INS/LA

3

-

-

... More
Plate Earthing (9.1.1) Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP

12

-

-

... More
Copper earth Plate (9.1.2) Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results as per specification no. EA-EP

11

-

-

... More
Pipe Type Earthing (9.1.4) Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP

28

-

-

... More
G.I.Strep (9.2.3) Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.

50

-

-

... More
Copper Strip (9.2.7) Supplying and erecting copper strip of required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with insulating and non-corrosive bond with required joints As per specification no. EA-EP.

75

-

-

... More
Transformer 630 KVA (10.1.10) Supplying, installing, testing & commissioning 3 phase, 11/0.433 kV, 50 Hz., 630 kVA, Mineral oil immersed and naturally cooled outdoor type, Copper wound Non-sealed transformer delta/star connected additional neutral brought out on load side, temperature rise should not exceed 45℃ by thermometer in oil and 50℃ by the resistance method in winding at full load rating, using type A winding insulation (kraft paper) with HV tapping (with off load tap changer) off load +5 to -10 in steps of 2.5%, having 7 number of tap positions , with standard accessories complete with test certificate with losses below 1860 Watts at 50% load, 5300 Watts at 100% load as per IS:1180 (part 1) : 2014 with necessary permissions of Electrical Inspector, as per specification no SS- TR-NSL.

1

-

-

... More
Fencing (10.6.18) Supplying and erecting fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work erected in CC foundation and painted complete as per specification no SS-AS/FSG

42

-

-

... More
Corner Support (10.6.19) Supplying and erecting 50 x 50 x 6 mm angle iron as corner support 2m long fixed at the middle of the fencing frame and the other side inclined at 30 degree angle, in cement concrete foundation of 15 x 15 x 40 cm complete duly painted with one coat of red oxide and two coats aluminium paint complete.

10

-

-

... More
Double Door (10.6.20) Supplying and erecting double leaf hinged door each 1500 mm in width x 1850 mm in height using B class, GI pipe with angle iron supports, chain link wire mesh (jali) complete supported on channel iron, erected in foundation, and painted complete as per specification no SS-AS/DLD

2

-

-

... More
Barbed Wire (10.6.21) Supplying & erecting barbed wire two ply with 12 SWG ply and 12 SWG barb with a gap between two bars of 75 mm. firmly fixed on provided angle supports with necessary materials complete. (6.044 meters/kg.).

38

-

-

... More
(10.6.22) Providing printed instruction chart for treating persons suffering from electric shock, printed in English & Marathi and duly laminated complete.

2

-

-

... More
Rubber Hand Gloves (10.6.23) Providing pair of duly tested rubber hand gloves as per IS :47705 suitable for working up to 22 kV supply complete.

2

-

-

... More
First Aid Box (10.6.24) Supplying standard first aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use, scissors, anti-septic solution, etc. (All above contents shall be of standard makes)

18

-

-

... More
Mat (10.6.25) Supplying and fixing PVC synthetic elastomer electrically insulating mat with class A insulation conforming to IS: 15652 – 2006 having 2 mm thickness up to 3.3 kV

68

-

-

... More
Mat (10.6.26) Supplying and fixing PVC synthetic elastomer electrically insulating mat with class B insulation conforming to IS: 15652 – 2006 having 2.5 mm thickness up to 11 kV

28

-

-

... More
D.G. Set 500 KVA (11.1.21) Supplying, erecting, testing and commissioning of diesel generating set with alternator of 500 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 81.90 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 690 Ltr etc. on provided M20 Grade CC Foundation and obtaining necessary approval from Electrical Inspector as per specification no. GEN-DG

1

-

-

... More
AMF Panel (11.2.18) Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 400 kVA up to 500 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF.

1

-

-

... More
Excavating (16.1.5) Excavating hard Rock or bituminous road by chiselling for preparing pit for pole / stay/earth plate / for laying cable/ pipe & clearing the site by removing debris & making the site as required complete. (6.1 x 2.5 = 15.25)

15.25

-

-

... More
Brick Masonry (16.2.1) Providing and making second class Burnt Brick masonry with conventional /I.S. type bricks in cement mortar 1:6 in foundation sand plinth of inner walls /in plinth external walls including bailing out water manually, striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete.

9

-

-

... More
Stone Metal 25 mm (16.2.3) Supplying and spreading stone metal 25 mm size for 100 mm depth above the ground level complete.

90

-

-

... More
R.C.C. (16.2.4) Providing and fixing reinforced cement concrete cover of size 60 cm x 45 cm with frame over inspection chamber etc. complete of medium duty (100 Kilogram).

25

-

-

... More
Transformer Plinth (16.3.1) Making transformer plinth (2 x 2 x 2) m in size with necessary excavation in ground with 150 mm. thick M- 10 PCC at the bottom and top and 250 mm. thick, burnt brick wall constructed at periphery and remaining hollow portion shall be filled with 40mm hard broken aggregate. External surface duly plastered by 12 mm thick including watering etc complete. (1.5 m x 1.5 m x 1.5 m Plinth Rate 14302 + (15x820 Per 100 mm increas = 12300/- Additonal 500 m (L) + 500 Mtr. (w) +1500 (H))

1

-

-

... More
C.C. Foundation (16.3.4) Making cement concrete foundation including excavation (60 x 60) cm x deep 1/6 of pole length in 1:3:6 cement concrete 20 x 25 mm stone metal, 45 cm x 45 cm x 45 cm /45 cm dia. x 45 cm. height plinth duly plastered, with necessary curing and finishing complete. (for above 9 m poles)

4

-

-

... More
C.C. Foundation (16.3.7) Making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose).(6.1 x 2.5 x 2 = 30.5)

30.5

-

-

... More
C.C. Foundation for Pole (16.3.9) Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole).

28

-

-

... More
C.C. Foundation (16.3.12) Making M- 20 cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq. m at 2 m depth including excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 12.5 m raising lowering high mast).

2

-

-

... More
Water Pump PVC Trunking 32 mm (1.2.8) Supplying and erecting PVC trunking (PVC casing-n-capping) of size 32 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.

40

-

-

... More
Change Over Switch (5.1.1) Supplying & erecting four pole ON LOAD change over switch, 415V, 32A, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, rotary handle, operational current category AC23A complying to IS/IEC 60947-3 Part-1/3 .

1

-

-

... More
TPMCB 40 A to 63 A (5.3.11) Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

3

-

-

... More
FPMCB 40 A to 63 A (5.3.13) Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

1

-

-

... More
D.P. MCB (5.4.13) Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame.

4

-

-

... More
Plywood 12 mm (6.1.12) Supplying and erecting plywood 12 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners supports, nuts bolts etc. complete.

2

-

-

... More
Iron Work (6.1.19) Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.

30

-

-

... More
Plate Earthing (9.1.1) Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP

2

-

-

... More
(12.1.1) Supplying & erecting Minimum three & above star rated Centrifugal water pump (Monoblock), 230V, Single phase 50 cycles A.C. supply of 0.375 kW/0.5 HP with discharge 36/9 Litres per Minute (LPM) for head of 6/21m & 25 mm suction/ 25 mm delivery pipe on provided C.C. foundation as per specification No. WP-CGP

2

-

-

... More
Submersible Pump (12.2.19) Supplying and erecting minimum Three & above star rated submersible pump set of 4.5 KW/6 HP with 415 V, 50 c/s AC supply suitable for 150 mm dia. borewell suitable for 60 to 180 LPM discharge at 177 to 88 m head & discharge & delivery pipe of Size-50 mm diameter with a necessary H type clamps as per specification No. WP-SMP

1

-

-

... More
Flat Flexible 3x4 sq.mm. Cable (12.4.9) Supplying & erecting flat flexible 3 core 4 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete.

160

-

-

... More
Automatic Control Panel (12.4.17) Supplying & erecting automatic control panel for 3 Phase , 415 volt, A.C, Submersible/centrifugal pump set up to 7.5 HP consisting of DOL starter having relay range 9-14 AMP,S.P.P., Combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc .

3

-

-

... More
G.I. Pipe 50 mm (16.5.6) Supplying and erecting ISI mark GI pipe 50 mm dia.‘B’ class at position with accessories complete as per specification no. CW-PLB/GP.

140

-

-

... More
Non Return Valve 50 mm Dia (16.6.21) Supplying and erecting non return valve 50 mm dia in position made of gun metal complete.

3

-

-

... More
On Grid Solar System 100 KWP On-Grid Solar PV System (4.5.7) Supplying, installing, testing and commissioning of 100 kWp ON-GRID Solar PV System / Plant consisting Solar PV Poly Crystalline Panel (335 Wp X 300 Nos.) and Solar ON-GRID Inverter of similar capacity (THD3%) with interconnecting wires / cables up to solar ON GRID inverter, proper base plate, canopy box to house Inverter and necessary accessories i.e. ACDB/ DCDB , MCB etc. wiring up to solar Inverter in casing and capping, display board, sign board, two distinct earthing, lightning arrester, liaisoning charges, remote monitoring system with maintaining card / chip for 5 years including net charges for RMS System, complete up to net meter Installation and export to the grid with 5 year ON-SITE warranty and fully comprehensive maintenance contract as per Specification no. ESD-RT-ONG.

1

-

-

... More
MCCB 04 Pole (5.5.2) Providing & erecting 4 Pole MCCB, 415V, 200A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB

2

-

-

... More
Bus Bar Support (5.10.27) Supplying & erecting porcelain/epoxy bus bar support complete erected in provided M.S. box for 200/300A

8

-

-

... More
S.S. Enclosure (5.11.18) Supplying and erecting SS enclosure for MCCB suitable for 125A to 200A MCCB.

2

-

-

... More
CRCA Sheet (6.1.1) Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete.

20.8

-

-

... More
Iron Work (6.1.19) Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.

6144

-

-

... More
(6.2.11) Supplying and erecting of any size electrolyte aluminium patti or bar in bus bar chamber / in panel or any other purpose, 500 V with require capacity 99.9% aluminium purity with E91E Grade as per IS 5082 & Current Density 0.8 A per sq. mm. with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as per specification no. BCP-BB

1.6

-

-

... More
Net Meter (6.3.15) Supplying and erecting AC three phase HT CT multifunction net meter DLMS compliance of accuracy class 0.5, 3x 63.5V, 50Hz, with backlit LCD display, optical port & RS 232 port( measures import kWh, kVAh, export kWh, kVAh, net kWh, kVAh, V, I, kW, 6 months history of energy, load survey, TOD, tamper detection & logging, power ON/OFF events, instantaneous parameters of rating 1/5A with display in absence of power) with wiring connections and mounting hardware on provided panels complete with calibration certificate from manufacturer.

1

-

-

... More
Energy Meter DLMS (6.3.17) Supplying and erecting Three phase smart energy meter DLMS compliance with 3x240V 50 cycles AC supply 10-60 A, ISI mark, accuracy class 1.0 with backlit LCD display, measuring & display V, I, kW, kWh, PF, kVA, kVAr, MD, day, week, month & with communication module configurable for GSM/Wi-Fi, IrDA/Bluetooth, complete provided panel with calibration certificate from manufacturer & duly wired with required size of PVC wires.

1

-

-

... More
FR XLPE Cable 4 x 25 (7.2.40) Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 120 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU

70

-

-

... More
D.W.C. Pipe 50 mm (7.6.9) Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.

25

-

-

... More
Plate Earthing (9.1.1) Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP

4

-

-

... More
Copper Strip (9.2.7) Supplying and erecting copper strip of required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with insulating and non-corrosive bond with required joints As per specification no. EA-EP.

50

-

-

... More
SMF Battery (3.8.10) Supplying and erecting 12V/42Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete

4

-

-

... More
Core Cutting (3.11.77) Carrying out core cutting of size 3" to 5" dia x 15" length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. (Note-02)

22

-

-

... More
Iron Work (6.1.19) Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.

1485

-

-

... More
Cable FR XLPE 3x6 sq.mm. (7.1.9) Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

55

-

-

... More
Cable 3½ core 25 sq. mm. (7.1.15) Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

55

-

-

... More
FR XLPE 4x10 sq.mm. (7.1.28) Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

170

-

-

... More
D.O.L Starter (12.4.2) Supplying & erecting D.O.L Starter suitable for 415 V, 3 phase 50 cycles with no volt coil and overload element with necessary materials and connected to supply up to 7.5 H.P.

2

-

-

... More
(13.1.5) Supplying, installation, testing and commissioning of main fire pump (MFP / EP) suitable for water discharge of 2280 to 2850 LPM at 90 to 70 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 55kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal type, single stage, centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation on with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/EP

1

-

-

... More
Jockey Fire Pump (13.2.1) Supplying, installation, testing and commissioning of jockey fire pump (JP) suitable for water discharge of 180 to 240 LPM at 70 to 50 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 5.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal/vertical type, multi stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003)complete, as per specification no. FF-MFP/JP

1

-

-

... More
Booster fire Pump (13.3.2) Supplying, installation, testing and commissioning of booster fire pump [BP] suitable for water discharge of 900 LPM at 35 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 7.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal/vertical type, single/multi stage, centrifugal casing pump of cast iron body & bronze/CI impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation on with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d)Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/BP

1

-

-

... More
Main fire Pump (13.4.2) Supplying, installation, testing and commissioning of main fire pump (MFP/DP) suitable for water discharge of 2280 to 2850 LPM at 90 to 60 m head driven by 76 HP or suitable HP capacity diesel engine at required working speed suitable for manual/automatic operation and consisting of following : (a) Horizontal type, single stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520. (b) Water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12/24 volts DC electric starting equipment with battery of required AH capacity with necessary charger suitable to work on 230v, 50Hz AC supply, diesel tank of minimum 150ltr capacity with first filling of diesel up to 100% level with necessary piping with valves up to engine , exhaust pipe extended up to 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications etc. as required. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with engine assembly and accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/DP

1

-

-

... More
Fire Pump Control Panel (13.5.1) Supplying, erecting, testing & commissioning of fire pump control panel (FCP) of cubical construction, floor mounted type, fabricated from minimum 2 mm thick CRCA sheet, compartmentalised with hinged lockable doors, with enclosure protection class IP54, duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnection with suitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessories, mountings and internal wiring with adequate size copper conductor cable, earth terminals, numbering etc. complete in all respect, suitable for satisfactory operation of main fire pump and jockey (pressurisation) pumps (1working+1standby) with necessary accessories, wiring & cabling along with allied accessories with following incoming and outgoings, suitable for automatic & manual operation on 415V, 3 phase, 50Hz ac supply as per specifications the capacity of electric motor driven pump are as follows a. Main fire pump(MFP) having capacity of 22kW 1no (1 working) b. Jockey pump(JP) capacity of suitable capacity 2 nos(1 working +1 standby, alternate run per start in auto mode) comprises of the following features & switchgears: 1. Main incomer FP SFU having rotary handle with HRC fuses of suitable rating. 2. Electrolytic grade copper strips for busbar of suitable sizes for main incomer and branches to motor SFU's, starters & outgoing terminals with necessary accessories like stainless steel nut bolts with spring washers for connections, mounted on required no of epoxy or porcelain support insulators of suitable ratings etc. 3. Individual pump TPN SFU having rotary handle with HRC fuses of suitable rating.

1

-

-

... More
For main electic motor driven fire hydrant system pump of 55 KW capacity & Relevant Capaicty jockey Pump

1

-

-

... More
For addition of standby main diesel engine driven fire pump (1 standby), add as follows in the basic cost of Item no 13-5-1 towards required 12/24 v battery charger and diesel engine starter along with necessary accessories, indicators etc. with necessary interlocking and updation of control logic with interlocking for operation of pumps MFP for main (1working+1standby mode) & jockey fire pumps (1working+1standby, alternate run per start in auto mode) , add Rs....... The control for diesel engine comprises of automatic/manual selector switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode indicating lamp for high/ low Lub. oil pressure, high water temp and engine on indication battery charger suitable for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC voltmeter, and 0-20 A DC ammeter with all standard relays and accessories required for automatic operation of diesel engine with interlocking for operation of main fire pumps.

1

-

-

... More
for 5.5/ 7.5 kW centrifugal type booster pump 1no(1working) , add Rs…....

1

-

-

... More
G.I. Pipe ERW 25 mm (13.6.2) Supplying and erecting G.I. pipe ‘C’ class ERW 25 mm dia with necessary fittings complete as per specification no. FF-PP

2420

-

-

... More
G.I. Pipe ERW 50 mm (13.6.3) Supplying and erecting G.I. pipe ‘C’ class ERW 50 mm dia with necessary fittings complete as per specification no. FF-PP

82

-

-

... More
G.I. Pipe ERW 75/80 mm (13.6.5) Supplying and erecting G.I. pipe ‘C’ class ERW 75/80 mm dia with necessary fittings complete as per specification no. FF-PP

33

-

-

... More
G.I. Pipe ERW 100 mm (13.6.6) Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm dia with necessary fittings complete as per specification no. FF-PP

1249

-

-

... More
G.I. Pipe ERW 150 mm (13.6.7) Supplying and erecting G.I. pipe ‘C’ class ERW 150 mm dia with necessary fittings complete as per specification no. FF-PP

638

-

-

... More
G.I. Pipe ERW 200 mm (13.6.8) Supplying and erecting G.I. pipe ‘C’ class ERW 200 mm dia with necessary fittings complete as per specification no. FF-PP

86.58

-

-

... More
(13.6.9) Providing coating of bitumen paint & 4mm thick wrapping for underground 100 mm ring main of fire fighting system.

110

-

-

... More
Foot Valve 100 mm dia (13.7.2) Supplying and erecting 100 mm dia cast iron foot valve ball type/flap type with strainer for negative suction complete as per specification no. FF-VL/FV

3

-

-

... More
Foot Valve 200 mm dia (13.7.4) Supplying and erecting 200 mm dia cast iron foot valve ball type/flap type with strainer for negative suction complete as per specification no. FF-VL/FV

3

-

-

... More
Line Strainer 100 mm (13.7.6) Supplying and erecting 100 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS

3

-

-

... More
Line Strainer 200 mm (13.7.8) Supplying and erecting 200 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, screen of SS end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS

3

-

-

... More
Sluice Valve (13.7.16) Supplying and erecting 200 mm dia. cast iron double flange sluice valve complete with PN16 pressure rating, as per specification no. FF-VL/SV

3

-

-

... More
Butterfly Valve 50 mm (13.7.17) Supplying and erecting 50 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV

15

-

-

... More
Butterfly Valve 100 mm (13.7.20) Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV

5

-

-

... More
Butterfly Valve 150 mm (13.7.21) Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV

22

-

-

... More
Butterfly Valve 200 mm (13.7.22) Supplying and erecting 200 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV

7

-

-

... More
NRV 100 mm dia (13.7.24) Supplying and erecting 100 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV

5

-

-

... More
NRV 200 mm dia (13.7.26) Supplying and erecting 200 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV

5

-

-

... More
Hydrant Valve (13.7.35) Supplying and erecting stainless steel single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV

27

-

-

... More
Fibre Water Tank (13.8.1) Supplying and installing one piece moulded HDPE / fibre water tank for negative suction only, having capacity 1000 litres fitted with necessary accessories complete as per specification no. FF-FFA/PT

2

-

-

... More
Hose reel (13.8.2) Supplying and installing wall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) along with necessary accessories complete as per specification no. FF-FFA/HV

13

-

-

... More
R.R.L. (13.8.4) Supplying and erecting 63mm dia, reinforced rubber lined (R.R.L.) hose pipe, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL

55

-

-

... More
Nozzle (13.8.8) Supplying and erecting stainless steel branch pipe 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specifications no. FF-FFA/NZ

27

-

-

... More
Fire Brigade Header 150 mm (13.8.10) Supplying and erecting 150 mm dia fire brigade header suitable for supplying water in fire tank complete as per specification no. FF-FA/FBC

4

-

-

... More
Siamese Connection (13.8.11) Supplying and erecting fire brigade header ( Siamese connection )of 150 mm dia, for supplying water in fire tank complete as per specification no. FF-FA/FMC

4

-

-

... More
(13.8.12) Supplying and erecting 300 mm dia 1.5m in height air vessel / tank fabricated from min 5mm thick M.S. sheet complete as per specification no. FF-FFA/ACT

3

-

-

... More
Air Release Cock (13.8.13) Supplying and erecting 20/25mm dia gun metal air release cock, with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV

3

-

-

... More
Pressure Gauge (13.8.14) Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, erected with provided G.I. pipe, elbow etc. complete as per specification no. FF-FFA/PG

5

-

-

... More
Pressure Switch (13.8.15) Supplying and erecting 12/15 mm dia pressure switch with provided isolation valve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS

6

-

-

... More
(13.8.19) Supplying and erecting M.S./CRCA cabinet for housing Fire Brigade / SIEMESE connections (size 1250 x 400 x 300 mm.) made from 16 SWG sheet and angle iron 25 mm. x 25 mm. x 4 mm. having front doors with viewing glass (8" x 6") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5)

27

-

-

... More
Arm. Cable 2x1.5 sq.mm (13.9.10) Supplying, installing, testing and commissioning FR, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU

6555

-

-

... More
Fire Alarm Panel (13.10.2) Supplying, installing, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the 2 loop capacity and capable of supporting upto 250 devices and detectors per loop, with on-board LCD display with min 16 lines of text, operating at 230 V 50 HZ - AC with inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 min in alarm condition, suitable provision for network connectivity, interfacing with third party equipment via a MODBUS/ OPC/ L-ON interface etc. conforming to IS 15908:2021, IS 2189: 2008, EN 54 & VDS / FM/ UL 864 (10th edition) with 3 years replacement warranty FF-AFAS/CP.

1

-

-

... More
Smoke Detector (13.10.6) Supplying, installing, testing and commissioning of addressable optical smoke detector, single/twin LED’s with 360 degree view, suitable for low voltage 15 to 32 V DC two wires supply, in-built locking mechanism to check the removal and pilferage of the detector, in built isolation mode, start up current 300µA and alarm condition current shall be maximum 6.5 mA, operating temperature 0°C to 50°C, humidity 0-95% RH, IP 41, conforming to IS 2189: 2008, 11360_1985_Reff2020 EN 54 or UL Approved with 3 years equipment replacement warranty FF-AFAS/SD .

859

-

-

... More
Manual Call Points (13.10.9) Supplying, installing, testing and commissioning of addressable manual call points ( break glass type/pull station type), made of addressable break glass plastic square in shape surface/flush mounted with "Break Glass" massage embedded on the glass, complete erected with mounting base and required accessories conforming to EN 54 or UL listed with 3 years equipment replacement warranty FF-AFAS/MCP.

31

-

-

... More
Addressable Fire Control (13.10.10) Supplying, installing, testing and commissioning of addressable fire control/relay module complete as required, with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 reed relays, EN 54 or UL Listed FF-AFAS/CRM

15

-

-

... More
Addressable Fire Isolator Module (13.10.12) Supplying, installing, testing and commissioning of addressable fire isolator module complete as required. EN 54 /FM or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/ISM

15

-

-

... More
(13.10.13) Supplying, installing, testing and commissioning of addressable horn cum strobe sound/ hooter, output frequency 500 to 1000 Hz with dB as per Chart given in IS 15908:2021, with flashing at 1 Hz over the strobe’s entire operating voltage range EN 54, conforming to IS 2189: 2008, IS 15908:2021 standards with 3 years equipment replacement warranty FF-AFAS/SSH.

31

-

-

... More
Quartzoid Bulb Sprinkler (13.12.1) Supplying, erecting, testing and commissioning of quartzoid bulb sprinkler, 15 mm (½") dia. NBCM Body chrome finished, 68º C fixed temperature rating with deflector disc of conventional construction complete as per specification no. FF-SPR.

2006

-

-

... More
CO2 (13.15.1) Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete.

15

-

-

... More
Non C.S.R. Supplying and erecting ABC powder type fire extinguisher as per IS : 13849 /15683 of 6 kg capacity with necessary clamp for erection on wall.

44

-

-

... More
Non C.S.R. Supplying and erecting Fire Exit Signages of viewing form 15 m length photolumicient type with standard accessories complete(size 300 x100mm)

40

-

-

... More
Non C.S.R. Supply installation testing, jointing and commissioning of Support comprising of threaded suspension rod with bullet fastener, threaded at both ends, flexible sleeve with supporting arrangement for sprinkler piping of various diameters , completein all respect

200

-

-

... More
Non C.S.R. Supplying and erecting Rose plates for sprinklers.

2006

-

-

... More
Non C.S.R. Providing and fixing UL/Fm listed SS braided flexible pipe 1000/1200mm long with accessories complete with all accessories specified in technical specifications(Size=15B)

1200

-

-

... More
Conduit 25 mm (1.2.4) Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with PVC accessories on wall /ceiling as per specification No: WG-MA/CON.

100

-

-

... More
Mains 1x1.5 sq.mm (1.3.1) Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW

120

-

-

... More
Mains 2x1.5 sq.mm (1.3.1) Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW

120

-

-

... More
Mains 1x4 sq.mm (1.3.3) Supplying and erecting mains with 1x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW

50

-

-

... More
Mains 2x4 sq.mm (1.3.3) Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW

50

-

-

... More
Modular Switch 6 A (1.6.1) Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.

24

-

-

... More
Modular Switch 16 A (1.6.2) Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete.

12

-

-

... More
Modular Socket 6A (1.6.10) Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.

24

-

-

... More
Modular Socket 16A (1.6.11) Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.

12

-

-

... More
Modular Step Regulator (1.6.23) Supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete.

4

-

-

... More
Modular 6 way Box (1.6.30) Supplying and erecting PVC Surface modular switch box with double mounting plate for 6 module duly erected.

12

-

-

... More
Light Point (1.7.19) Point wiring for light/bell/exhaust fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW

16

-

-

... More
Fan Point (1.7.20) Point wiring for ceiling fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW

4

-

-

... More
Down Lighter (2.1.6) Supplying and erecting LED square / circular Max. 25 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2750 Lumens, min. efficacy of 110 lumen/W, CRI80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD10%, p.f. 0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.

20

-

-

... More
B.L.D.C. Ceiling fan (2.10.22) Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of 28W having service ratio (CMM/W) of Min. 8 , PF0.9, THD10% with IR remote control/compatible speed regulator, Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF (Without Remote )

4

-

-

... More
Eshaust Fan (2.10.14) Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 225mm. 1400 RPM rust proof body & blades, wire mesh, duly erected, complete.

8

-

-

... More
Fan Hook (2.11.4) Supplying and erecting fan hook of 10 mm. M.S. round bar grouted in RCC slab with making the site as original.

4

-

-

... More
Down Rod (2.11.6) Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire.

4

-

-

... More
Recess (2.11.11) Providing recess in brick wall suitable for erection of exhaust fan up to 450mm. sweep complete with grouting of nut, bolts, plastering and colour washing to match the colour of the wall for the wall thickness of 225 mm.

8

-

-

... More
Metal Cawl (2.11.14) Supplying & erecting 22 SWG G.I sheet metal cawl sector shaped with 25 x 25 x 3 (mm) angle iron frame, metal mesh to avoid birds entry with necessary material, suitable for exhaust fan of 300 mm as per specification no FG-FAS/MSC

8

-

-

... More
SPMCB 6 A to 32 A (5.3.2) Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

6

-

-

... More
SPMCB 6 A to 32 A (5.3.3) Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

6

-

-

... More
SPNDB (5.4.8) Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB

4

-

-

... More
D.P. MCB (5.4.13) Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame.

8

-

-

... More
02 Pole RCBO (5.6.10) Supplying, fixing and commissioning 2 pole RCBO 32/40A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO

4

-

-

... More
04 Pole RCCB (5.6.15) Providing, erecting & commissioning 4 pole RCCB 40A, with added immunity to avoid DC pulse tripping with 30/100/300 mA sensitivity complete as per specification no. SW-RCCB/RCCB

6

-

-

... More
2 X 2.5 sq. Mtr. (7.2.8) Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 2.5 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU

25

-

-

... More
2 X 4 sq. Mtr. (7.2.9) Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 4 sq mm copper conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU

200

-

-

... More
FR XLPE Cable 4 x 10 (7.2.33) Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU

118.64

-

-

... More
Galvanized Iron Earth Plate (9.1.3) Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials, testing & recording the results as per specification no. EA-EP

12

-

-

... More
G.I.Strep (9.2.3) Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.

200

-

-

... More
20 Passenger Cum Stretcher Lift (17.1.10) SITC of Electric Traction Passenger cum Stretcher/Hospital Lift with Rated capacity :- 20 Passenger/1360Kg m , Floors :- G+6 floor (7 Stops/7 Landings) , Travel :- 21 to 29 Mtr., Location of Lift Machine:- MR/MRL, Rated speed :- 1.0mps VS Car/Landing door clear opening of 1100/1200 mm wide x 2000 mm high , Clear Car size of 2000 .mm wide x 3000 mm deep x 2250mm high Lift shaft available having clear size of 2170 .mm wide x 3230 .mm deep, 4250 mm Pit depth, ………mm Overhead. , Doors type :- COPO/TOPO Doors with frame made from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge., COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor., LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings. Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters, The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. , ARD complete with necessary SMF VRLA batteries. , Fireman controller having fireman switch at fire Landing.

4

-

-

... More
For Lift travelling above First floor & up to Sixth floor

4

-

-

... More
For Lift having 1100mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade solid(non-cladded) landing door [Two panel], this includes all necessary accessories like LOP's with UP/DN buttons-arrows-indicators, extension of guide rails, shaft wiring with trunking, travelling cables, main hoisting ropes/belts, & OSG rope landing doors with all accessories etc. necessary for the normal safe functioning of lift installation complete.

20

-

-

... More
Duplex Lift Control System (17.1.21) SITC of Duplex Lift control system for two nos. microprocessor/PLC based simplex lift controllers along with necessary software with programming and hardware e.g. logic board, necessary communication/control/data cabling laying in rigid PVC conduits/trunking etc. complete.

2

-

-

... More
PVC Trunking 25 mm (1.2.7) Supplying and erecting PVC trunking (PVC casing-n-capping) of size 25 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.

220

-

-

... More
Mains 1x2.5 sq.mm (1.3.2) Supplying and erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW

110

-

-

... More
Mains 2x4 sq.mm (1.3.3) Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW

110

-

-

... More
Co-axial Copper cable (1.8.18) Supplying & erecting co-axial copper cable low voltage grade tri-shielded RG-11 as per specification No. WG-TW

500

-

-

... More
18 H.P. VRF A.C. System (3.11.7) Supplying, erecting, testing and commissioning of 18HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/ digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete.

2

-

-

... More
28 H.P. VRF A.C. System (3.11.12) Supplying, erecting, testing and commissioning of 28HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete.

3

-

-

... More
Hi-wall type indoor unit (IDU) (3.11.15) Supply, installation, testing and commissioning of VRF/VRV based Hi-wall type indoor unit (IDU) of nominal cooling capacity 1.3TR (421 cfm) to 1.7TR (586 cfm) having EER as per BEE standards and specifications with multiple speed evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, expansion device, cordless remote control with necessary controls, with 3-core copper flexible cord of required length and electrical terminal to receive power supply, etc. IDU shall have anticorrosive coating suitable for coastal area. Unit shall be suitable for indoor wall mounting, having an electronic control console, provided with suitable mounting brackets with any additional refrigerant and oil charge as per the requirement during installation, connected to the system complete.

1

-

-

... More
Hi-wall type indoor unit (IDU) (3.11.16) Supply, installation, testing and commissioning of VRF/VRV based Hi-wall type indoor unit (IDU) of nominal cooling capacity 1.8TR (594 cfm) to 2.2TR (655 cfm) having EER as per BEE standards and specifications with multiple speed evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, expansion device, cordless remote control with necessary controls, with 3-core copper flexible cord of required length and electrical terminal to receive power supply, etc. IDU shall have anticorrosive coating suitable for coastal area. Unit shall be suitable for indoor wall mounting, having an electronic control console, provided with suitable mounting brackets with any additional refrigerant and oil charge as per the requirement during installation, connected to the system complete.

2

-

-

... More
VRF/VRV Based Ceiling Suspended cassate Unit (3.11.20) Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact/standard size) of nominal cooling capacity 2.0TR (618 cfm) to 2.3TR (671 cfm) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation.

1

-

-

... More
VRF/VRV Based Ceiling Suspended cassate Unit (3.11.22) Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 3.0TR (1100 cfm) to 3.2TR (1165 cfm) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation.

9

-

-

... More
VRF/VRV Based Ceiling Suspended cassate Unit (3.11.23) Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 3.3TR (1165 cfm) to 4.0TR (1218 cfm ) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation.

2

-

-

... More
VRF/VRV Indoor Unit (3.11.54) Supply, installation, testing and commissioning of VRV / VRF based ductable type, high static room/indoor unit (IDU) having nominal cooling capacity of 4.1TR (1640 cfm) to 5.0TR (2000 cfm) having EER as per BEE standards and specifications with evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, in built drain pump, expansion device, cordless remote control with necessary controls and electrical terminal to receive power supply, etc. having anti-corrosive coating suitable for coastal area and decorative slim dimension suitable for ceiling suspended arrangement with an electronic control console and any additional refrigerant and oil charge as per requirement during installation complete.

1

-

-

... More
VRF/VRV Indoor Unit (3.11.56) Supply, installation, testing and commissioning of VRV / VRF based ductable type, high static room/indoor unit (IDU) having nominal cooling capacity of 8.0TR (3200 cfm) having EER as per BEE standards and specifications with evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, in built drain pump, expansion device, cordless remote control with necessary controls and electrical terminal to receive power supply, etc. having anti-corrosive coating suitable for coastal area and decorative slim dimension suitable for ceiling suspended arrangement with an electronic control console and any additional refrigerant and oil charge as per requirement during installation complete.

3

-

-

... More
Remotecontrol Panel (HMI) (3.11.79) Supplying, erecting, testing and commissioning centralised programmable remote control panel (HMI) touch manager controls minimum 16 system of 64 ODU's can be controlled and up to 992 IDU's can be individually mounted and controlled indoor units having colour min 200mm size LCD touch panel, yearly schedule, power proportional distribution function, temperature limitation, history function complete erected on wall integrated with provided fire alarm system.

2

-

-

... More
(3.11.82) Supply, fabrication, installation and testing of flexible canvas connections constructed between ductable unit/dampers/ducting of suitable size with fire resist flexible double canvas sleeve complete.

8

-

-

... More
Y or T Joins (3.11.86) Supplying and installation of high pressure grade required size copper connection Y or T- Joints/refnet complete erected on wall/ceiling with supports/raceways, Nitrile rubber insulation, painting etc. with brazing and testing for leakages confirming the normal operation of the VRV/VRF air conditioning system.

24

-

-

... More
(3.11.88) Supplying and erecting aluminium powder coated linear grill of suitable size for width length without collar dampers having matching colour with the existing false ceiling and suitable for deflection of 15/30/45°.

90

-

-

... More
Copper Pipe 41.3 mm dia (3.11.89) Supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 41.3mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete.

90

-

-

... More
Copper Pipe 34.9 mm dia (3.11.90) Supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 34.9mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete.

90

-

-

... More
Copper Pipe 22.2 mm dia (3.11.92) supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 22.2mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiation with OEM standards of VRV/VRF air conditioning system complete.

90

-

-

... More
Copper Pipe 19.1 mm dia (3.11.93) supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 19.1mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete.

90

-

-

... More
Copper Pipe 15.9 mm dia (3.11.94) supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 15.9 mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete.

110

-

-

... More
Copper Pipe 12.7 mm dia (3.11.95) supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 12.7mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete.

110

-

-

... More
Copper Pipe 9.5 mm dia (3.11.96) supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 9.5 mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete.

80

-

-

... More
SPMCB 6 A to 32 A (5.3.2) Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

36

-

-

... More
DPMCB (5.3.8) Supplying, erecting & marking DPMCB 40A to 63A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

5

-

-

... More
FPMCB 40 A to 63 A (5.3.13) Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

1

-

-

... More
TPNDB (5.4.1) Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 4 ways/phase (12 poles), with door, 1.2mm thickness, surface/flush mounted, IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB

1

-

-

... More
SPNDB (5.4.8) Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB

5

-

-

... More
TPMCB 40 A to 63 A (5.3.11) Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

5

-

-

... More
MCCB 04 Pole (5.5.1) Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB

1

-

-

... More
TPNDB 4 Way (5.4.15) Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/ 4 pole MCCB as incomer & outgoing SP MCB (12 poles) or TP MCB of 4 ways (12 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1

1

-

-

... More
Prewired Meter (5.7.17) Providing & erecting prewired meter module suitable for MCCB panel board with CTs and emfs VIF meter.

1

-

-

... More
Iron Work (6.1.19) Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.

800

-

-

... More
Cable FR XLPE 2x6 sq.mm. (7.1.5) Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

100

-

-

... More
Arm. cable 3½ core 95 sq. mm. (7.1.19) Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 95 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

100

-

-

... More
FR XLPE 4x25 sq.mm. (7.1.30) Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

100

-

-

... More
AHU AHU: Supply, Testing and Commissioning of Air Handling Units for Operation Theater & ICU Area As per Below Specifications: AIR HANDLING UNIT : CE Marked, Air Flow: 2000 CFM & Static Pressure: 125 MM WGAHU Panel: PANELS: 45mm thick Double skin with thermal profile with PUF insulation of density 40kg/m3 with mixing chamber, Outer Skin 24 G Pre Coated & Inner Skin 24 G GI Sheet.Filteration: Non Woven Type Pre Filter, Fine Filter & Terminal Hepa Filter 99.97% down to 0.2 micron , Cooling COIL : UL certified 4 / 6 row deep DX coil with anticorrosive hydrophilic Coating blue fins with SS 304 drain pan with insulation.FAN: Nikotra or Kruger make Backword Curve DIDW Fan with spring type vibration isolators for reducing vibrations, Fan outlet velocity up to 8.50 M/s for reducing noise.MOTOR : TEFC Squirrel gauge IP 55 VFD Compatible induction motor, Marathon/ Crompton/BBL make IE3, HEATERS : 14Kw, SS 304 finned type heaters, Thyristor controller for heaters.DAMPER : Manually operated Alluminum Supply air, Return air, Fresh air damper, Motorised alluminum damper for bypass pass air , AHU DX KIT & CONTROLLER BOX, DX Connection KIT with Controller BOX for AHU,Corded AHU Controller Remote and Suitable for VRF Outdoor units (Design as per ISHRAE Norms)

6

-

-

... More
GI DUCTING WITH INSULATION GI Ducting with Insulation: Supply and installation of 24 gauge GI rectangular ducting with required supports, fittings and Thermal Insulation of class `O' 19 mm thick nitrile rubber insualtion

600

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.