Public Works Department Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Public Works Department - PWD Tender

Works
Electronics Equipment
Building Construction
Eprocure
Opening Date30 Dec 2024
Closing Soon23 Jan 2025
Tender Amount₹ 1,00,72,43,763 
Notes
Download

Costs

  • EMD

    ₹ 50,81,000
  • Document Cost

    ₹ 5,900
  • Tender Fee

    ₹ 500

Summary

Construction Of O.p.d. And Ward Building In Premises Of Government Medical College

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Excavation for foundation in earth, soils of all types, sand,gravel and soft murum, including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5m to 3.0m) By Mechanical Means OPD BUILDING

1813.7

-

-

... More
Excavation for foundation in hard murum including removing the excavated material upto distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.50 m) By Mechanical Means OPD BUILDING/SUBSTATION/INFRASTRUCTURE WORK/PUMP ROOM

4954.71

-

-

... More
Excavation for foundation in Hard murum and boulders including removing the excavated material upto a distance of 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5 m to 3.0 m.) By Mechanical Means OPD BUILDING/SUBSTATION

1025

-

-

... More
Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth/murum, ramming ,watering including shoring and strutting etc. complete. (Lift from 1.5m To 3.0 m.) By Mechanical Means OPD BUILDING

1031

-

-

... More
Excavation for foundation in hard murum and boulders including removing the excavated material up to a distance 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5m.) By Mechanical Means INFRASTRUCTURE WORK/PUMP ROOM

1663

-

-

... More
Filling in plinth and floors with approved excavated material in 15cm. to 20cm. Layers including watering and compacting etc. complete. OPD BUILDING/SUBSTATION/INFRASTRUCTURE WORK/PUMP ROOM

4042

-

-

... More
Filling in plinth and floors with contractors material / brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete.OPD BUILDING

1470

-

-

... More
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper.OPD BUILDING/ SUBSTATION/ INFRASTRUCTURE WORK/ PUMP ROOM

8976

-

-

... More
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) treatment by treating the backfill in immediate contact with foundation at the rate of 5 litres of emulsion concentrate of 1.0 percent of clorophyrifos per One Square Metre of vertical surface area covering 10 years guarantee on bond paper.OPD BUILDING

3119.28

-

-

... More
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per One Square Metre of surface area covering ten years guarantee on bond paper.OPD BUILDING

2982.05

-

-

... More
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-I) to the soil along the external face of building by punching holes of 1.2 of 1.5 C.M. diametre about 30 -60 cm deep at 15 cm c/c as close to the wall as possible and to inject 0.5 percent of aldrin or clorophyrifos at the rate of 7.5 litres per hole and sealing the same with proper filling and covering 10 years guarantee on bond paper.OPD BUILDING

2982.05

-

-

... More
Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete.OPD BUILDING/ SUBSTATION/ INFRASTRUCTURE WORK/ PUMP ROOM

1111.36

-

-

... More
Providing and laying Cast in situ/Ready Mix cement Concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand.OPD BUILDING/ SUBSTATION/ INFRASTRUCTURE WORK/ PUMP ROOM

1297.27

-

-

... More
Providing and laying Cast in situ/Ready Mixcement Concrete in M20 of trap/ granite/quartzite/gneiss metal for Steps / Screed / Grade Slab, including steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) SSR Sr. No. 827, Item No. 24.06, Page No. 131, Bd.E2 Page No. 288 and B7 Page No. 38. SUBSTATION/INFRASTRUCTURE WORK/PUMP ROOM

77

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering, formwork ,cover blocks, laying/pumping, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)OPD BUILDING/SUBSTATION/INFRASTRUCTURE WORK

3967

-

-

... More
Providing and laying Cast in situ / Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal fo R.C.C. columns as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) OPD BUILDING-Ground Floor

607

-

-

... More
FIirst Floor

301

-

-

... More
WARD- Second Floor

250.81

-

-

... More
Third Floor

250.81

-

-

... More
Fourth Floor

425.68

-

-

... More
SUBSTATION-Ground Floor/Terrace floor/INFRASTRUCTURE WORK

110

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)OPD BUILDING-Ground Floor

513.33

-

-

... More
FIirst Floor

265.5

-

-

... More
WARD -Second Floor

269

-

-

... More
Third Floor

249.33

-

-

... More
Fourth Floor

255.75

-

-

... More
SUBSTATION

42

-

-

... More
INFRASTRUCTURE WORK

97

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)OPD BUILDING-Ground Floor

553.56

-

-

... More
FIirst Floor

553.56

-

-

... More
WARD -Second Floor

461.3

-

-

... More
Third Floor

461.3

-

-

... More
Fourth Floor

491.06

-

-

... More
SUBSTATION

26

-

-

... More
INFRASTRUCTURE WORK

7

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap / quartzite/granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)OPD BUILDING-Ground Floor

44

-

-

... More
FIirst Floor

40

-

-

... More
WARD -Second Floor

30

-

-

... More
Third Floor

44

-

-

... More
Fourth Floor

44

-

-

... More
PUMP ROOM--Ground Floor

10

-

-

... More
FIirst Floor

10

-

-

... More
Providing and laying Cast in situ/Ready Mixcement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) OPD BUILDING--Ground Floor

27

-

-

... More
FIirst Floor

54

-

-

... More
WARD--Second Floor

57.89

-

-

... More
Third Floor

57.89

-

-

... More
Fourth Floor

57.89

-

-

... More
SUBSTATION

2

-

-

... More
PUMP ROOM

2

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)OPD BUILDING/Ground Floor

77.14

-

-

... More
FIirst Floor

36.68

-

-

... More
WARD--Second Floor

36

-

-

... More
Third Floor

45

-

-

... More
Fourth Floor

90

-

-

... More
Providing and laying Cast in situ / Ready Mix cement concrete M-25 of trap / granite / quartzite / gneiss metal for R.C.C. canopy as per detailed designs and drawings including steel centering, formwork, laying / pumping, compacting and roughening the surface if special finish is to be provided and curing etc.complete (excluding reinforcement). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc.complete. With fine aggregate (Crushed sand VSI Grade)OPD BUILDING-Ground Floor

62.94

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C.coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including steel centering, formwork, cover blocks, laying / pumping, compacting , curing , finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)OPD BUILDING-Ground Floor

27

-

-

... More
FIirst Floor

6

-

-

... More
WARD--Second Floor

4

-

-

... More
Third Floor

4

-

-

... More
Fourth Floor

5

-

-

... More
SUBSTATION

13

-

-

... More
INFRASTRUCTURE WORK

13

-

-

... More
PUMP ROOM

15

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. columns as per detailed designs and drawing or as directed including Steel centering formwork, cover blocks laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)PUMP ROOM

963

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawings or as directed including centering, formwork, cover blocks compacting and roughening if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand.PUMP ROOM--Ground Floor

13

-

-

... More
1st floor

22

-

-

... More
2nd floor

22

-

-

... More
Terrace floor

5

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite/quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)PUMP ROOM--Ground Floor

8

-

-

... More
1st floor

22

-

-

... More
2nd floor

69

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)PUMP ROOM--Ground Floor

19

-

-

... More
1st floor

125

-

-

... More
Providing and laying Cast in situ/Ready Mix cement concrete in M-30 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)PUMP ROOM upto 5 m

762

-

-

... More
Above 5 m (add 12.5%)

1072

-

-

... More
Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc.as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.OPD BUILDING-Ground Floor

715.12

-

-

... More
FIirst Floor

283.23

-

-

... More
WARD --Second Floor

251.82

-

-

... More
Third Floor

248.84

-

-

... More
Fourth Floor

324.79

-

-

... More
SUBSTATION

18

-

-

... More
INFRASTRUCTURE WORK

95

-

-

... More
PUMP ROOM--Ground Floor

85.8

-

-

... More
FIirst Floor

283.23

-

-

... More
Providing fly ash brick masonry with conventional / I.S. type fly ash bricks in C.M. 1:6 in foundation and plinth including bailing out water manually striking joints, racking out joints watering and scaffolding etc. complete.OPD BUILDING/SUBSTATION/INFRASTRUCTURE WORK/PUMP ROOM

160

-

-

... More
Providing fly ash brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete INFRASTRUCTURE WORK

7

-

-

... More
PUMP ROOM

130

-

-

... More
Providing Auto claved Aerated Concrete block masonry of Ecolite or equivalent make conforming to IS :2185 (Part-3)-1984 in extra find jointing mortar of fixo block of Ultratech or equivalent in Superstructure including striking joints, raking out joints and scaffolding etc.complete. (The test shall be carried out conforming to IS:6441(Part01) 1972. As directed by Engineer-In-Charge.OPD BUILDING/Ground Floor

828

-

-

... More
FIirst Floor

790

-

-

... More
SUBSTATION

92

-

-

... More
WARD --Second Floor

704

-

-

... More
Third Floor

450

-

-

... More
Fourth Floor

849

-

-

... More
Terrace Floor

1154

-

-

... More
Providing Autoclaved Aerated Concrete Block masonary of conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in Half brick thick wall including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972)OPD BUILDING-Ground Floor

1429.9

-

-

... More
FIirst Floor

1342.63

-

-

... More
WARD --Second Floor

1342.63

-

-

... More
Third Floor

1342.63

-

-

... More
Fourth Floor

1342.63

-

-

... More
Providing and laying damp proof course 50 mm thick in M20 cement concrete layer and bitumen / using cement with waterproofing compound curing, formwork etc.complete.OPD BUILDING/ INFRASTRUCTURE WORK

97

-

-

... More
Providing and laying cement concrete flooring 40 mm thick with M15 cement concrete laid to proper level and slope in alternate bays including compaction, filling joints, marking lines to give the appearance of tiles of 30 cm x 30 cm or other size laid diagonally/ square etc finishing smooth (with extra cement) in any colour as directed and curing etc. complete. With Crushed Sand.OPD BUILDING

267

-

-

... More
Providing and laying cement concrete flooring 50mm thick with M20 cement concrete laid to proper level and slope in alternate bays including compaction, filling joints, marking lines to give the appearance of tiles of 30cm x 30cm or other size laid diagonally/ square etc. finishing smooth (with extra cement) in any colour as directed and curing etc. complete.with Crushed sand VSI Grade PUMP ROOM

61

-

-

... More
Providing and applying water proofing treatment using acrylic polymer modified cement based water proofing coating with fibre glass mesh mixing at the rate of powder to liquid (2:1) by weight covering 9 to 10 Square Metre /Kilogram with two coat using approved chemicals for masonry and concrete surface by brush covering 7 years guarantee on Stamp Papers etc. complete.PUMP ROOM

2755

-

-

... More
Providing and applying required coats of a water based Evercrete Deep Penetrating Sealer (DPS) on cement concrete surface like roads, beams, and columns, plastered walls, basements, roofs, potable water tanks etc to react with cement and to penetrate concrete structure thereby making it resistant to chemicals / chlorides water to make it dust proof and to act as a water resistant at the same time which Strengthens the treated surface and reduce the curing period etc complete. - Note -- for item One Number 7 to 4 prior approval of Superintending Engineer will be necessary-PUMP ROOM

1624

-

-

... More
Providing and fixing 20 to 25 mm thick rough shahabad box type waterproofing treatment to vertical outside faces of Reinforced Cement concrete walls of basement or underground floor including filling the gap of 25 mm between rough shahabad and R.C.C. walls with cement grout mixed with water proofing liquid Algae proof or other alike with one tile lift method, brushing the joints horizontally with cement slurry mixed with water proofing liquid for width 30 to 35 mm and sloping coping over topmost tile with cement mortar 1:3, butting the bottom most with Cement concrete 1:2:4 mixed with water proofing liquid, curing, with 7 years guarantee on court fee stamp of Rs.100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete)OPD BUILDING/Ground Floor

23.56

-

-

... More
First Floor

23.56

-

-

... More
PUMP ROOM

844

-

-

... More
Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1Kilogramper bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete.-WARD

3562

-

-

... More
SUBSTATION

174

-

-

... More
INFRASTRUCTURE WORK

38

-

-

... More
PUMP ROOM

843

-

-

... More
Providing waterproofing in W.C. and bath including brick bat coba in all position including providing and laying 12mm bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound @ 1Kilogram/per bag of cement laying brick bat coba of required thickness in cm 1:5 with waterproofing compound 1 Kilogram/bag of cement grouting and finishing the top layer with 20mm thick brick bedding in cm mortor 1:3 with waterproofing compound 1 Kilogram/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etc. complete.OPD BUILDING-Ground Floor

189.53

-

-

... More
FIirst Floor

237.37

-

-

... More
WARD -Second Floor

237.37

-

-

... More
Third Floor

237.37

-

-

... More
Fourth Floor

237.37

-

-

... More
Providing waterproof plaster in W.C. and bath 12 mm thick for dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of 1 Kilogram. per bag of cement of approved make and manufacturer and curing etc. complete. (Excluding Tiles) (As directed by Engineer in Charge)OPD BUILDING-Ground Floor

510

-

-

... More
FIirst Floor

761

-

-

... More
WARD --Second Floor

602

-

-

... More
Third Floor

601

-

-

... More
Fourth Floor

868

-

-

... More
Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete.OPD BUILDING-Ground Floor

2272

-

-

... More
FIirst Floor

2014.65

-

-

... More
WARD Second Floor

2232

-

-

... More
Third Floor

2233

-

-

... More
Fourth Floor

2232

-

-

... More
INFRASTRUCTURE WORK

149

-

-

... More
PUMP ROOM

995

-

-

... More
Providing and applying gypsum plaster ( with Gypsum material ) with finishing with gypsum material in 10 to 13 millimeter thickness to previously plastered surface / or on newly brick surface ( Excluding rough cast plaster ) in all position including preparing and Finishing the surface scaffolding etc.complete.OPD BUILDING-Ground Floor

2392

-

-

... More
FIirst Floor

1602

-

-

... More
WARD --Second Floor

1711

-

-

... More
Third Floor

1711

-

-

... More
Fourth Floor

3193

-

-

... More
SUBSTATION

522

-

-

... More
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete.OPD BUILDING--Ground Floor

1746.71

-

-

... More
FIirst Floor

1204.22

-

-

... More
WARD --Second Floor

1212.05

-

-

... More
Third Floor

1212.05

-

-

... More
Fourth Floor

2317.93

-

-

... More
SUBSTATION

558.69

-

-

... More
INFRASTRUCTURE WORK

1107.88

-

-

... More
PUMP ROOM

1141.34

-

-

... More
Providing patti / band 100 mm wide on plastered surface 12 mm to 15 mm thick in C.M. 1:3 line and level including neat finishing scaffolding curing etc. complete.OPD BUILDING-Ground Floor

268

-

-

... More
FIirst Floor

268

-

-

... More
WARD-Second Floor

268

-

-

... More
Third Floor

268

-

-

... More
Fourth Floor

268

-

-

... More
PUMP ROOM

64

-

-

... More
INFRASTRUCTURE WORK

44

-

-

... More
Providing patti/ band 75mm wide on plastered surface 12 mm to 15 mm thick in C.M. 1:3 line and level including neat finishing scaffolding curing etc. complete.SUBSTATION/INFRASTRUCTURE WORK/PUMP ROOM

43.8

-

-

... More
Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete.OPD BUILDING-Ground Floor

1925.14

-

-

... More
FIirst Floor

2103.56

-

-

... More
WARD --Second Floor

1763.86

-

-

... More
Third Floor

1763.86

-

-

... More
Fourth Floor

1763.86

-

-

... More
SUBSTATION

103.04

-

-

... More
PUMP ROOM

21.6

-

-

... More
Providing and applying Texture plaster with finishing with texture material of approved make in 3 to 4 millimeter thickness on previously plastered surface, including Plaster Groove 6mm thickness or Tape Grooves 35 to 45 mm thickness or as required, in all position including preparing the surface, scaffolding etc. complete.OPD BUILDING- Ground Floor

324.37

-

-

... More
FIirst Floor

188.35

-

-

... More
WARD Second Floor

249.1

-

-

... More
Third Floor

249.1

-

-

... More
Fourth Floor

417.42

-

-

... More
Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete.OPD BUILDING Ground Floor

218

-

-

... More
FIirst Floor

218

-

-

... More
WARD Second Floor

218

-

-

... More
Third Floor

218

-

-

... More
Fourth Floor

218

-

-

... More
INFRASTRUCTURE WORK

10

-

-

... More
Providing and laying polished hand cut Kotah Stone flooring 25mm to 30mm thick and 45cm to 55cm wide in plain/diamond pattern on a bed of 1:6 C.M. in flooring including cement float, filling joints with neat cement slurry, curing, polishing and cleaning complete.OPD BUILDING Ground Floor

77

-

-

... More
FIirst Floor

77

-

-

... More
WARD Second Floor

77

-

-

... More
Third Floor

85

-

-

... More
Fourth Floor

85

-

-

... More
SUBSTATION

147.5

-

-

... More
PUMP ROOM

261

-

-

... More
Providing and fixing in required position skirting or dado of polished Kotah Stone slab 25 mm to 30 mm thick fixed on base on plaster of cement mortar 1:4 including cement float, filling joints with cement slurry, curing rubbing, polishing and cleaning complete.OPD BUILDING Ground Floor

9

-

-

... More
FIirst Floor

9

-

-

... More
WARD Second Floor

9

-

-

... More
Third Floor

10

-

-

... More
Fourth Floor

10

-

-

... More
SUBSTATION

1.44

-

-

... More
PUMP ROOM

11

-

-

... More
Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete.OPD BUILDING Ground Floor - For Flooring & Dado

386.87

-

-

... More
FIirst Floor - For Dado

72

-

-

... More
WARD Second Floor - For Dado

100.6

-

-

... More
Third Floor - For Dado

100.6

-

-

... More
Forth Floor - For Dado

100.6

-

-

... More
Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete.OPD BUILDING Ground Floor

1938

-

-

... More
FIirst Floor

2575

-

-

... More
WARD Second Floor

2353

-

-

... More
Third Floor

3215

-

-

... More
Forth Floor

3215

-

-

... More
INFRASTRUCTURE WORK

60

-

-

... More
Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete OPD BUILDING Ground Floor -Wall Tiles Dado

2192

-

-

... More
FIirst Floor -Wall Tiles Dado

2385

-

-

... More
WARD Second Floor -Wall Tiles Dado

2090.51

-

-

... More
Third Floor -Wall Tiles Dado

2091.53

-

-

... More
Forth Floor -Wall Tiles Dado

2301

-

-

... More
INFRASTRUCTURE WORK

6

-

-

... More
Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete OPD BUILDING Ground Floor

0.44

-

-

... More
FIirst Floor

0.09

-

-

... More
PUMP ROOM

2

-

-

... More
Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etc. complete.OPD BUILDING Ground Floor - For Tread & Riser

447.11

-

-

... More
FIirst Floor - For Tread & Riser

440

-

-

... More
WARD Second Floor - For Tread & Riser

366

-

-

... More
Third Floor - For Tread & Riser

370

-

-

... More
Forth Floor - For Tread & Riser

367

-

-

... More
Providing and laying vitrified matt finish tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc.complete.OPD BUILDING Ground Floor - Toilet Dado

786

-

-

... More
FIirst Floor - Toilet Dado

1066

-

-

... More
WARD Second Floor - Toilet Dado

1066

-

-

... More
Third Floor - Toilet Dado

1066

-

-

... More
Forth Floor - Toilet Dado

1066

-

-

... More
Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 mm x 450 mm size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 mm thick supports with kadappah top 35 to 40 mm thick and polished granite 16 to 20 mm top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 cm height and top granite of 75 x 40 cm including cutting, opening for sink of required size in kadappah as well as granite etc. complete. (Platform top size 5.00 m x 0.60 m and height is 0.75 m)Same as above but for Flooring OPD BUILDING Ground Floor

22

-

-

... More
FIirst Floor

205.29

-

-

... More
WARD Second Floor

115.47

-

-

... More
Third Floor

163.25

-

-

... More
Forth Floor

226

-

-

... More
Providing and Fixing 32 mm thick One piece single moulded puff ABSTRONE BUTADYNE STYRINE (ABS) Door shutter for internal use including toilets made up of outer ABS sheet of 1.2 mm thick having puff insulation of 35 to 40 Kilogram/One Cubic Metredensity and 10 mm dia.for steel bars 2 Nos., wooden block to receive fixtures, having M.S. hinges 100 mm length, M.S. handles 150 mm length and 10 mm dia sliding door bolt etc. complete OPD BUILDING Ground Floor

50.72

-

-

... More
1st Floor

71.19

-

-

... More
WARD 2nd Floor

91

-

-

... More
3rd Floor

95

-

-

... More
4th Floor

95

-

-

... More
Providing and fixing 15 mm thick eco-friendly densified edge calcium silicate false ceiling of approved texture of size 595mm x 595mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections (galvanising at @12 gm/sq.m including both sides) consisting of main T runner suitably spaced at joints to get required length and size 24X38mm. made from 0.33mm thick(minimum ) sheet, spaced 1200mm center to center and cross T of size 24X28mm made of 0.33mm thick(minimum ) sheet to be interlocked at the middle of the 1200x600 mm panel to form the grid of size 600x600mm resting on periphery walls/partitions on a perimeter wall angle precoated steel of size 24x24x3000 made of 0.4 mm thick (minimum) sheet with the help of all plugs at 450mm and laying 15 mm thick densified edges calcium silicate ceiling tiles of approved texture (spintone/cosmos/hexa) in the grid, including light fittings , fixtures , smoke detectors etc., wherever required. Main T runners suspended from ceiling with using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling using 12.5mm dia. And 50mm long dash fasteners, 4mm G.I. adjustable rods with galvanized steel levels clips of size 85x30x0.8mm, spaced at 1200mm center to center along main T bottom exposed with 24mm of all T-sections shall be prepainted with polyester baked paint, for all heights, as per specifications, drawings etc. complete.(currently this item should be used only for VIP cabins)OPD BUILDING Ground Floor

3265

-

-

... More
First Floor

3265

-

-

... More
WARD 2nd Floor

3562

-

-

... More
3rd Floor

3562

-

-

... More
4th Floor

3562

-

-

... More
Providing & fixing factory-made steel door of Single leaf Internal Plain Wood finish type with a.) frame of size 100x58 mm conforming to IS 4351-2003 , 1.2 mm thick pre galvanized sheet with mitred and welded cones , frame stretches, hinge reinforcing plates , fixing plates and hardware mounting plates and Polyurethane foam infill b.) Shutter of thickness 46mm made of 0.8 mm thick slip coated pre galvanized steel sheet on both sides conforming to ASTM A527/ASTM A525, BS 2989 1994, IS 277 , Zinc coating 120 GSM . Lock formed panels with internal stiffeners of 3mm thick made of galvanized sheet, 3 mm thick hinge reinforcing hardware mounting plates and lock protection with Honey- comb craft paper infill of thickness 150 GSM of load bearing capacity 500 Kilogram/ One Square Metre. c.) Finish: Powder coated surface finished with thermosetting polyurethane paint of Aliphatic grade of thickness 60-micron d.) Accessories: Min 8 Anchor fastener of HILTI make, min 3 SS Ball Bearing Butt Hinges of Dorset make, Dorset cylindrical lock, SS Tower bolt of 200 mm size, Door stopper complete.OPD BUILDING Ground Floor

182.4

-

-

... More
1st Floor

139.2

-

-

... More
WARD 2nd Floor

30.8

-

-

... More
3rd Floor

26.4

-

-

... More
4th Floor

30.8

-

-

... More
Providing & fixing factory-made steel door of Single leaf External Embossed Wood finish type with a.) frame of size 100x58 mm conforming to IS : 4351-2003 , 1.2 mm thick pre galvanized sheet with mitred and welded cones , frame stretches, hinge reinforcing plates , fixing plates and hardware mounting plates and Polyurethane foam infill b.) Shutter of thickness 46mm made of 0.8 mm thick slip coated pre galvanized steel sheet on both sides conforming to ASTM A527/ASTM A525, BS 2989 1994, IS 277 , Zinc coating 120 GSM . Lock formed panels with internal stiffeners of 3mm thick made of galvanized sheet, 3 mm thick hinge reinforcing hardware mounting plates and lock protection with Honey- comb craft paper infill of thickness 150 GSM of load bearing capacity 500 Kilogram/ One Square Metre. c.) Finish: Powder coated surface finished with thermosetting polyurethane paint of Aliphatic grade of thickness 60-micron d.) Accessories: Min 8 Anchor fastener of HILTI make, min 3 SS Ball Bearing Butt Hinges of Dorset make, Dorset Mortise lock, SS Tower bolt of 200 mm size, Eye hole, Door stopper complete.PUMP ROOM

3

-

-

... More
Providing and fixing of factory made uPVC Sliding window & door (White Colour) complete, comprising uPVC multi-chambered frame having in-built uPVC roller track on top and uPVC sash with wall thickness of 2.3mm (+-0.2 mm), duly reinforced with G.I. section 1.5 mm, wherever required. uPVC window & door profile shall be made in India & shall conform to BS EN 12608 and other standards as mentioned below: S.No. Name of the test Test Method Specified Parameter 1 Tensile Impact Strength ISO 8256 - more than 700 KJ/m2 2 Vicat Softening Temperature EN ISO – 306 Shall not be 750C 3 Charpy Impact Strength EN ISO – 179-2 Shall not be 20 KJ/m2 4 Flexural Modulus Elasticity EN ISO – 178 Shall not be 2200 N/mm2 5 Mean Breaking Stress for welded corner (a) For the tensile bending test EN – 514 Shall not be 25 N/mm2 (b) For the compression bending test Shall not be 30 N/mm2 6 Heat Reversion Test IS:4985-2000 Shall not be 2.0 % 7 Surface Spread of flame BS : 476 - Part 7 Classification 1 8 Ignitability Evaluation BS : 476 - Part 5 'P' Not easily ignitable 9 Tensile modulus ASTM D 638 Shall not be 35 MPa 10 Shear Modulus ASTM D 732 Shall not be 220 MPa 11 Tensile Strength EN ISO 527 Shall not be 30 MPa All corners of frame and sash will be fusion welded. After placing 5 mm Float Annealed glass in the sash, uPVC glazing bead, interlock, EPDM / TPE gasket, brush shall be provided including touch lock and rollers & proper drainage system shall be provided. Window / Door will be fixed to the wall with 100 mm long and 8 mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge. uPVC Window and Door Profiles are warranted for a period of ten (10) years against non-uniform discoloration, wrapping and rotting under general use.2 Track 2 / 4 Sash (Big Series) window frame of size 67 x 54 mm & Sash of size 64 x 47 mm OPD BUILDING Ground Floor

171

-

-

... More
1st Floor

196

-

-

... More
WARD 2nd Floor

199

-

-

... More
3rd Floor

83

-

-

... More
4th Floor

83

-

-

... More
3 Track with Mesh-2 Glass Sash + 1 Mesh Sash (Each sash shall be half of width of window) (Big Series) Window frame of size 122 x 54 mm & Sash of size 64 x 47 mm.OPD BUILDING Ground Floor

20

-

-

... More
1st Floor

20

-

-

... More
WARD 2nd Floor

20

-

-

... More
3rd Floor

20

-

-

... More
4th Floor

20

-

-

... More
Providing and fixing factory made uPVC twin sash casement glazed window and door (White Colour) comprising of two shutters, one outward opening having glass and one inward opening having SS Mesh and integrated grill provision between two shutters. uPVC multi-chambered frame, sash, bugmesh sash and mullion (where ever required) extruded profiles with wall thickness of 2.3mm (+-0.2 mm) duly reinforced with G.I section 1.50 wherever required. uPVC window & door profile shall be made in India & shall conform to BS EN 12608 and other standards as mentioned below: S.No. Name of the test Test Method Specified Parameter-1 Tensile Impact Strength ISO 8256 - more than 700 KJ/m2 2 Vicat Softening Temperature EN ISO – 306 Shall not be 750C 3 Charpy Impact Strength EN ISO – 179-2 Shall not be 20 KJ/m2 4 Flexural Modulus Elasticity EN ISO – 178 Shall not be 2200 N/mm2 5 Mean Breaking Stress for welded corner (a) For the tensile bending test EN – 514 Shall not be 25 N/mm2 (b) For the compression bending test Shall not be 30 N/mm2 6 Heat Reversion Test IS:4985-2000 Shall not be 2.0 % 7 Surface Spread of flame BS : 476 - Part 7 Classification 1 8 Ignitability Evaluation BS : 476 - Part 5 'P' Not easily ignitable 9 Tensile modulus ASTM D 638 Shall not be 35 MPa 10 Shear Modulus ASTM D 732 Shall not be 220 MPa 11 Tensile Strength EN ISO 527 Shall not be 30 MPa. All corners of frame and sash will be fusion welded. Mullion shall be welded / screwed. EPDM / TPE Gasket shall be provided in all frame, sash & mullion, wherever necessary.Thereafter, 5 mm Float Annealed glass shall be provided in the sash with the help of uPVC glazing bead and hardware, i.e., friction hinge & single point handle (in window) & 3D Hinges & Multipoint Lock (in door) shall be provided. Window / Door shall be fixed to the wall with 100 mm long and 8 mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge.uPVC Window and Door Profiles are warranted for a period of ten (10) years against non-Fixed Window (Big Series) frame of size 67 x 62 mm & Mullion (if required) of size 67 x 78 mm.OPD BUILDING Ground Floor

22

-

-

... More
1st Floor

22

-

-

... More
WARD 2nd Floor

22

-

-

... More
3rd Floor

196

-

-

... More
4th Floor

196

-

-

... More
Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 mm x 1.22 mm box type, 5 mm thick sheet glass louvers, of approved quality etc. complete.OPD BUILDING Ground Floor

17

-

-

... More
1st Floor

22

-

-

... More
WARD 2nd Floor

24

-

-

... More
3rd Floor

25

-

-

... More
4th Floor

50

-

-

... More
Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete.OPD BUILDING Ground Floor

139.2

-

-

... More
FIirst Floor

138

-

-

... More
WARD Second Floor

59.4

-

-

... More
Third Floor

68.2

-

-

... More
Fourth Floor

66

-

-

... More
Providing and fixing solid core flush door shutter in double leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete.OPD BUILDING Ground Floor

61

-

-

... More
FIirst Floor

44

-

-

... More
WARD Second Floor

13.2

-

-

... More
Third Floor

13.2

-

-

... More
Fourth Floor

22

-

-

... More
Providing and fixing Country cut teak wood double or single leaf second class fully panelled door shutter with 35mm thick style and rail with 25 mm thick panels with openable fan light as per detailed drawings. Excluding the door frame 60mm x 100mm stainless steel fixtures and fastening and finishing the wood work with oil painting 3 coats. (Excluding the door frame)OPD BUILDING Ground Floor

12

-

-

... More
FIirst Floor

12

-

-

... More
Providing and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/ One Square Metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete.OPD BUILDING Ground Floor

136

-

-

... More
FIirst Floor

301

-

-

... More
WARD Second Floor

146

-

-

... More
Third Floor

61

-

-

... More
Fourth Floor

61

-

-

... More
PUMP ROOM

27

-

-

... More
Providing and fixing four folded double leaf door with 40 x40 x4 mm thk mild steel suare hollow pipe, 16 mm square bar at interval of 15 cm c/c, , decorative designed grill at center leaf with hinges frame door, both side handdle, locking arrangement etc including surface prepration, two coats of red oxide primer and two coats of synthatic enamel painting OPD BUILDING

72

-

-

... More
Providing & fixing factory-made Single leaf 2 hour fire rated door as per IS 3614 Part 2 & BS 476 Part 20 & 22, tested to UL 10 C and conforming to NFPA 80 , tested at NTL /CBRI/ARAI of Plain Steel finish type with a.) Frame of size 143x58 mm and thickness of 1.6 mm thick skin pass galvanized iron sheet (Conform to IS 277 ) formed to single or double rebate profile b.) Shutter of 46 mm thickness and constructed from 1.2 mm thick skin pas galvanized iron sheet (Conform to IS 277) infill Rockwool / Mineral wool/ Honey comb craft paper c.) Vision glass of 5mm thick clear/wired glass Circular or Rectangular d.) Finish : Primed with zinc phosphate stoving primer and finished with Polyurethane aliphatic grade or epoxy paint as required of thickness 60 micron e.) Accessories : Min 8 Anchor fastener of HILTI make, min 3 SS Ball Bearing Butt Hinges, Mortise sash lock with lever handle, Mortise dead bolt , Mortise latch , Door closer , Panic bar and external trim lock and Flush bolts complete.OPD BUILDING Ground Floor

28.8

-

-

... More
FIirst Floor

28.8

-

-

... More
WARD Second Floor

9.6

-

-

... More
Third Floor

9.6

-

-

... More
Fourth Floor

9.6

-

-

... More
SUBSTATION

12

-

-

... More
Providing and fixing in position. (as per I.S.1868 / 1982) Aluminium sliding window of two tracks with rectangular pipe having overall dimension 63.50 x 38.10 x 1.02 mm at weight 0.547 Kilogram/One Running Metre. and window frame bottom track section 61.85 x 31.75 x 1.20 mm at weight 0.695 Kilogram/One Running Metre. Top and side track section 61.85 x 31.75 x 1.30 mm at weight 0.659 Kilogram/One Running Metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/One Running Metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/One Running Metre. And handle section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/One Running Metre. and top section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass with all required screws and nuts etc, complete. With powder coating with box SUBSTATION/INFRASTRUCTURE WORK/PUMP ROOM

57

-

-

... More
Providng and fixing in position anodised extruded aluminum partitions, partly glazed and partly laminated having frame made out of extruded tubular section of size 40 mm x 60 mm with 12 mm thick three layered flat pressed teak wood particle board bonded with BWP type exterior grade phenol formaldehyde synthetic resin conforming to IS 12823-1990, laminated on both sides,Novateakor equivalent and 5 mm thick selected quality plain/ float glass panels fixed with aluminum glass clips 12 mm x 12 mm and rubber cushioning beading to glass partitions as per approved drawing etc. compete OPD BUILDING Ground Floor

815.16

-

-

... More
First Floor

510.42

-

-

... More
WARD Second Floor

149.61

-

-

... More
Third Floor

149.61

-

-

... More
Fourth Floor

149.61

-

-

... More
Providing and fixing 900mm high S.S.304 Grade Stainless steel railing with 40mm diameter and 1.5mm thick at top, 40mm diameter and 1.5mm thick vertical supports spaced at 1.5m center to center and 8mm thick toughened glass including fabricating ,fixtures, errecting , necessary welding , grinding , finishing, buffing to stainless steel pipe etc. complete OPD BUILDING Ground Floor

783

-

-

... More
FIirst Floor

366

-

-

... More
WARD Second Floor

731

-

-

... More
Third Floor

731

-

-

... More
Fourth Floor

731

-

-

... More
SUBSTATION

19

-

-

... More
INFRASTRUCTURE WORK

14

-

-

... More
PUMP ROOM

120

-

-

... More
Providing and fixing 900mm high S.S.304 Grade Stainless steel railing with 40mm diameter for Staircase Side Wall approximate wt 4 kg/m for stair case flight with supports at approx. at 1000 mm c/c. Refer typical detail drawing.Note: Railing Items shall be measured as total length of completed pipe hand railing (not individual pipe lengths)PUMP ROOM Ground Floor

12.5

-

-

... More
FIirst Floor

7.5

-

-

... More
Supply, fabrication and installation of cage ladder with structure comprising matt finish of SS 304 grade angles channels, flats, tubes etc, of all the components as per final detailed drawing. Complete inlcuding all labour equipment, up to any lead and lift as directed by ELC PUMP ROOM Ground Floor

7200

-

-

... More
Providing and fixing in position, Single shuttered aluminium extruded powder coated openable door of overall size 0.90 m x 2.40 m with aluminium door frame of powder coated section 101.60 x 44.75mm , 3.18 mm thick and shutter comprising of powder coated section having bottom and lock rail of size 150 mm x 44.5 mm x 3.00 mm thick top rails 47.62 x 44.45 mm x 3.00 mm thick , vertical style 47.62 x 44.45 mm, 3.00 mm thick and for shutter plain glass panes 5 mm thick for top panels and 12mm thick both side laminated phenol bonded particle board panels for bottom panels etc. , I.S.I. mark , heavy duty, Hydraulic floor spring of 150Kilogramcapacity , having heavy duty concealed lock, necessary beading, glazing clips, PVC gaskets, 250mm length tower bolts, 150mm diam. pad handle, etc. as per detailed design and drawing or as directed by engineer in charge including all materials , labours, and equipment etc.Complete INFRASTRUCTURE WORK

8

-

-

... More
Providing and fixing mild steel grill gate as per the detailed drawing including hinges, locking arrangements and painting in three coats of oil paint of approved colour and shade etc. complete.(weight 18 Kilogram. to 20 Kilogram. Per Sq.m.) Spec.One Number: As directed by Engineer- in-charge.INFRASTRUCTURE WORK

335

-

-

... More
Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 mm with lock plate of 3.15 mm thickness reinforced with 35 x 35 x 5 mm angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65 mm and 3.15 mm respectively with hold fast arrangements, M.S. Bracket plate 300 x 300 x 3.15 mm minimum size and shape with square bar, suspension shaft of minimum 32 mm diameter, hood cover of M.S. sheet not less than 0.9 mm thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc. complete. (I.S. 62481979) (With mechanical gear)SUBSTATION Ground Floor

7

-

-

... More
Full Height Partitions in Solid finish - Providing and Fixing 80mm to 85mm thick Full height Double Skin partition up to 3 mtr height with All visible sections in Anodized / Powdercoated finish. Made up of Frames and Tiles. Frame construction In combinaton of Aluminium Rails and Bottom ,Center and Top members, Connected with 2 way Round Shape Post , 3way Post , 4 way Post made up of Aluminium Extruded and Tiles in 9mm thk. Prelaminated Partical Board of on both side. With all the Joints in the partitions covered with PVC extrusions to provide better sound Proofing. Tiles to be separated 55mm from each other to provide adequate space for drawing cables for electric, data and telephone with proper facility for fixing electrical and data switch plates. as per design and drawing.OPD BUILDING Ground Floor

377

-

-

... More
First Floor

278

-

-

... More
WARD Second Floor

278

-

-

... More
Third Floor

278

-

-

... More
Forth Floor

394

-

-

... More
Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete.OPD BUILDING Ground Floor

2493.47

-

-

... More
First Floor

2815.6

-

-

... More
WARD Second Floor

2557.6

-

-

... More
Third Floor

3391.11

-

-

... More
Forth Floor

3391.11

-

-

... More
Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc.complete.OPD BUILDING Ground Floor

4885.47

-

-

... More
First Floor

4417.6

-

-

... More
WARD Second Floor

4268.6

-

-

... More
Third Floor

5102.11

-

-

... More
Forth Floor

6584.11

-

-

... More
Providing and applying 2 coats of 100% Pure Acrylic low VOC and APEO & HCHO free water based Paint of approved colour that belongs to class 1 flame spread resistance of approved make Paint should provide durable and long lasting silk finish with a high crack tolerance of upto 1mm. Paint should have an oustanding washability with high resistance to wide range of bacteria and fungus. Paint has to be applied on smooth and uniform surface prepared by an acrylic copolymer low VOC & Odour putty. This surface should be primed with water based low VOC Primer. The work activity should cover all aspects of applying paints from surface preparation as directed by Engineer in charge. SSR Sr. No. 1611, Page No. 225, As directed by Engineer-In-Charge.OPD BUILDING Ground Floor

4885.47

-

-

... More
FIirst Floor

4417.6

-

-

... More
WARD Second Floor

4268.6

-

-

... More
Third Floor

5102.11

-

-

... More
Forth Floor

6584.11

-

-

... More
SUBSTATION

522

-

-

... More
Providing and applying two coats Apex Ultima Puranature Anti-Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC’s, CO, SOx, formaldehydes, etc.) in presence of natural or artificial light. It contains Graphene and nanoparticles of titanium oxide. and Absorbs CO2 (4.8 Kilogram/15 l). plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recommended applicator and he should be able to furnish stage wise onsite technical reports from the concerned company technologist.OPD BUILDING Ground Floor

2123.73

-

-

... More
FIirst Floor

1453.34

-

-

... More
WARD Second Floor

1461.15

-

-

... More
Third Floor

1461.15

-

-

... More
Forth Floor

2735.35

-

-

... More
SUBSTATION

558.69

-

-

... More
Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface ,applying primer coat ,scaffolding if necessary, and watering the surface for two days etc complete. NOTE: For Item One Number 15 to 18 prior approval of Superintending Engineer will be necessary INFRASTRUCTURE WORK PUMP ROOM

2249.22

-

-

... More
Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces. (excluding the primer coat.) etc. complete.INFRASTRUCTURE WORK PUMP ROOM

1144

-

-

... More
Providing and fixing 45 cm wide mild steel ladder of 40mm x 6 mm mild steel flat stringers and steps of 18 mm dia. mild steel bar for water tank including fixing it in (1:2:4) M-15 cement concrete block 60cm x 30cm x 30cm and painting the ladder complete. (Anti Corossive Paint)WARD -Ground Floor PUMP ROOM

44

-

-

... More
Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted / welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete.OPD BUILDING- SUBSTATION/ INFRASTRUCTURE WORK/PUMP ROOM

39.46

-

-

... More
Providing and applying two coats of synthetic enamel paint of approved colour to new /old structural steel work and wood work in buildings, including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete.OPD BUILDING/ SUBSTATION/ INFRASTRUCTURE WORK/ PUMP ROOM

3683

-

-

... More
Providing and fixing mild steel door using 40 x 40 x 4 mm hollow square pipe, 80 x 40 x 4 mm hollow pipe, 16 square mm pipe rod at interval of 15 cm, grill at center leaf with hinges including anodising tp door etc.complete OPD BUILDING

43

-

-

... More
Providing and fixing coloured glazed earthenware lipped flat back/corner type urinal with PVC 5 liters flushing cistern with fittings,capacity with fittings, inlet pipe and stop tap, brackets for fixing the cistern, P.V.C. flush pipe with fittings including lead soil pipe, lead trap and soil pipe connection up to the outside face of the wall.OPD BUILDING

132

-

-

... More
WARD Second Floor

12

-

-

... More
Third Floor

12

-

-

... More
Forth Floor

12

-

-

... More
Providing and fixing oval type under counter wash hand basin of 16 inch x 22 inch size and of special colour shade having telephonic black / coloured granite of 180 mm thick stone black kadappa framework including chromium plated coupling bottle - Trap using CERA company or equivalent oval typa wash basin model no 3448 as per detailed drawing or as directed by engg incharge etc complete. (Counter size 1.20 m x 0.60 m )OPD BUILDING

80

-

-

... More
WARD Second Floor

40

-

-

... More
Third Floor

41

-

-

... More
Forth Floor

40

-

-

... More
Providing and fixing 8 cm C.I. Nahani Trap including C.I. grating bend and piece of C.I. pipe upto the outside face of the wall complete.OPD BUILDING

200

-

-

... More
WARD Second Floor

60

-

-

... More
Third Floor

60

-

-

... More
Forth Floor

60

-

-

... More
Providing and fixing 450mm x 550mm size superior type Belgium Mirror with 16mm dia. nickel plated towel rod etc. complete. SSR Sr.No. 1574, Page No. 295, As directed by Engineer-In-Charge.OPD BUILDING

80

-

-

... More
WARD Second Floor

40

-

-

... More
Third Floor

41

-

-

... More
Forth Floor

40

-

-

... More
Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap.OPD BUILDING/ WARD

125

-

-

... More
Providing and laying for 150 mm dia salt glazed stoneware pipe including fittings Such as bends, tees, single junction, double junctions laying, jointing (including excavation and refilling the trenches) complete.OPD BUILDING

100

-

-

100

-

-

... More
Providing and fixing sink cock with regular swinging spout (Wall / floor Mounted Model) with wall flange having flow rate up to 6.0 Litr/Minute of Jaquar/Cera/Hindware /Perryware or equivalent make incluidng other necessary fitting, etc. complete as directed by Engineer in charge. (Make shall conform to manufacturer's Green product and shall got approved from the Engineer In Charge.)OPD BUILDING

150

-

-

20

-

-

... More
Providing and fixing C.P. 2 Way BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge.OPD BUILDING Ground Floor

112

-

-

... More
First Floor

111

-

-

... More
WARD Second Floor

118

-

-

... More
Third Floor

128

-

-

... More
Fourth Floor

120

-

-

... More
Providing , constructing and fixing 450 mm dia. Inspection chamber made up of Polypropylene / polyethylene material of thickness 3.5 mm and height of 388 mm with 160 or 200 mm main inlet (s) outlet and 110 and / or 160 mm branch inlets, with 450 mm dia. Ultra shaft pipe of HDPE material having height of 460 mm, having R.C.C. cover and frame fixing in 150 mm thick in c.c.1:2:4, having crushed sand bed of 150 mm thick of size 750 mm dia. Including excavation and refilling the sides of chamber by sand crushed cushioning 150 mm thickness, connecting all required UPVC fittings with rubber lubricant etc. complete.OPD BUILDING

70

-

-

... More
Providing , constructing and fixing 600 mm dia. Inspection chamber made up of Polypropylene / polyethylene material Having 315 mm diameter inlet(s)/outlets and with eccentric reducers as per requirement to connect 160 mm and 200 mm pipes having thickness of 5 mm and 600 mm in height, with inbuilt shaft achieve the invert depth as per site condition of wall thickness of 5 mm having R.C.C. cover and frame fixing in 150 mm thick in c.c.1:2:4, having crushed sand bed of 150 mm thick of size 750 mm dia. Including excavation and refilling the sides of chamber by ?sand crushed cushioning 150 mm thickness, connecting all required UPVC fittings with rubber lubricant etc.complete.OPD BUILDING

60

-

-

... More
Providing and fixing FRP Chamber perforated cover of size 60 cm x 45 cm with frame over inspection chamber etc. complete. Heavy duty (160kg)OPD BUILDING

240

-

-

... More
Providing and constructing Brick Masonary Electrical Chamber 120 cm x 120 cm x 120 cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channel half round G.S.W pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C cover medium duty 140 kilogram with frame etc complete.OPD BUILDING

20

-

-

... More
Construction grid chamber and grease trap chamber in brick masonry as indivated in consultants drawing, up to 1 m deep, (1.5 x 1.2 x 1 and 1.0 x 1.2 x 1) with first class brick in cement mortar 1:5 R, FRP cover ( heavy duty 20T), foundation concrete 1:4:8 mix, inside and outside plastering 12 mm thick with cement mortar 1:3 finished with a floating coat of neat cement inside with rounded corners in cement concrete 1:2:4 mix neatly finished complete as per standard design including excavation refilling and disposal of surplus earth.OPD BUILDING

10

-

-

... More
Providing and fixing Orissa Pan of size 580x445x260 mm with approved make flush valve including trap, C.I. soil and vent pipe upto outside face of wall including 100mm dia. C.I. plug, bend and necessary pipe connection, etc complete. As directed by Engineer in charge.OPD BUILDING Ground Floor

28

-

-

... More
First Floor

17

-

-

... More
WARD Second Floor

14

-

-

... More
Third Floor

14

-

-

... More
Fourth Floor

14

-

-

... More
Providing and fixing white European type wall-hung, Size 360mm x 360mm x 575 mm with flush valve having flow rate up to 6.0 Litr/Minute of Jaquar/Cera/Hindware /Perryware or equivalent make including PVC soil pipe, vent pipe upto outside face of wall, 100mm dia PVC plug bend inlet pipe all fittings,cutting & making good walls, floors etc as directed by Engineer in charge.( Make shall conform to manufacturer's Green product and shall got approved from the Engineer In Charge.)OPD BUILDING Ground Floor

12

-

-

... More
First Floor

16

-

-

... More
WARD Second Floor

13

-

-

... More
Third Floor

13

-

-

... More
Fourth Floor

13

-

-

... More
Providing and fixing white glazed earthenware sink 450mm x 200mm x 300mm including all connection of the G.I. supply and lead waste pipes up to the outside face of the wall, cold water chromium plated screw down bib tap, rolled steel or C.I. brackets,rubber plug with chain and stop tap complete.OPD BUILDING Ground Floor

10

-

-

... More
First Floor

10

-

-

... More
WARD Second Floor

10

-

-

... More
Third Floor

10

-

-

... More
Fourth Floor

10

-

-

... More
Providing and fixing wall mixer with overhead shower,shower arm,hand shower with wall bracket having flow rate up to 12 liters/minutes of Jaquar/Cera/Hindware /Perryware or equivalent make including all necessary pipes,fittings etc.complete as directed by Engineer In Charge.( Make shall conform to manufacturer's Green product and shall got approved from the Engineer In Charge.)OPD BUILDING Ground Floor

20

-

-

... More
First Floor

20

-

-

... More
WARD Second Floor

10

-

-

... More
Third Floor

10

-

-

... More
Fourth Floor

10

-

-

... More
Providing and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge.OPD BUILDING Ground Floor

28

-

-

... More
First Floor

17

-

-

... More
WARD Second Floor

17

-

-

... More
Third Floor

17

-

-

... More
Fourth Floor

19

-

-

... More
Providing and fixing white glazed urinal of size 710x460x300mm with sensotronic concealed type flushing valve for urinal with complete kit having fittings, inlet pipe with stop tap, brackets for fixing the cistern, 32mm diameter P.V.C. flush pipe with fitting and flushing arrangement including lead soil pipe, lead trap & soil pipe connection upto the outside face of wall etc complete.OPD BUILDING Ground Floor

20

-

-

... More
First Floor

26

-

-

... More
WARD Second Floor

16

-

-

... More
Third Floor

16

-

-

... More
Fourth Floor

16

-

-

... More
Providing and fixing P.V.C. Rain water pipes of 160mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and One Number, filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete.OPD BUILDING Ground Floor

516

-

-

... More
First Floor

282

-

-

... More
WARD Second Floor

400

-

-

... More
Third Floor

400

-

-

... More
Fourth Floor

400

-

-

... More
SUBSTATION

7

-

-

... More
INFRASTRUCTURE WORK

7

-

-

... More
PUMP ROOM

21

-

-

... More
Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.OPD BUILDING

1732

-

-

... More
WARD Second Floor

600

-

-

... More
Third Floor

600

-

-

... More
Fourth Floor

600

-

-

... More
Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.OPD BUILDING

2397

-

-

... More
WARD Second Floor

960

-

-

... More
Third Floor

960

-

-

... More
Fourth Floor

960

-

-

... More
Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.OPD BUILDING

915

-

-

... More
WARD Second Floor

500

-

-

... More
Third Floor

500

-

-

... More
Fourth Floor

500

-

-

... More
Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.OPD BUILDING

1260

-

-

... More
WARD Second Floor

600

-

-

... More
Third Floor

450

-

-

... More
Fourth Floor

400

-

-

... More
Providing and fixing on walls/ ceiling/ floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.OPD BUILDING

2400

-

-

... More
WARD Second Floor

450

-

-

... More
Third Floor

390

-

-

... More
Fourth Floor

400

-

-

... More
Providing and fixing C.P. pillar cock long neck with aerator of approed make including necessary sockets/union nut etc. complete.OPD BUILDING

22

-

-

... More
WARD Second Floor

40

-

-

... More
Third Floor

40

-

-

... More
Fourth Floor

40

-

-

... More
Providing and fixing C.P. sink cock with raised J" shaped swinging casted spout ofapproved make including necessary sockets/ union nut etc. complete.OPD BUILDING

27

-

-

... More
WARD Second Floor

40

-

-

... More
Third Floor

40

-

-

... More
Fourth Floor

40

-

-

... More
Providing and fixing on walls/ ceiling/ floor 32 mm dia. uPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.OPD BUILDING

83

-

-

... More
WARD Second Floor

150

-

-

... More
Third Floor

150

-

-

... More
Fourth Floor

150

-

-

... More
Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete OPD BUILDING

371

-

-

... More
WARD Second Floor

150

-

-

... More
Third Floor

150

-

-

... More
Fourth Floor

150

-

-

... More
Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete.OPD BUILDING

938

-

-

... More
WARD Second Floor

400

-

-

... More
Third Floor

250

-

-

... More
Fourth Floor

250

-

-

... More
Providing and fixing 50 mm. dia. medium class G.I.pipe gate with wicket gate of approved drawing with all fixtures and fittings in two leaves with strong hold fast embedded in c.c. block at top and bottom with locking arrangement including cutting, bending, making holes and with one coat of primer etc. complete.INFRASTRUCTURE WORK/SUBSTATION

65

-

-

... More
Providing, laying and testing HDPE Pipes (4 kg/cm² quality / PE63) including required specials e.g. bends, reducers/expanders, shoes, puddle flanges/blind flanges, welding of joints, clamps wherever required etc. and necessary accessories complete as directed and instructed by Engineer / Owner. If HDPE pipes are laid underground & buried the rate shall include laying them underground with proper slopes and levels. Excavation, backfilling and sand filling around pipes only shall be paid for separately under relevant items. INFRASTRUCTURE WORK Internal Diameter 100 mm Downtake pipe

200

-

-

... More
Internal Diameter 150 mm Underground Drain

150

-

-

... More
Internal Diameter 200 mm Underground Drain

550

-

-

... More
Providing,aupplying,fabricating and fixing panel of aluminium composite panel cladding in approved shape made out of 4 mm thick ACP sheet material consisting of 3mm thick FR grade mineral core following NBC part IV Fire and life safety (having 2 hours fire resistance in accordance to ASTM E119-12 and BS476 part 6 and 7 class O) sandwitched between two aluminium sheets (each 0.5 mm thick of AA 5005/AA3105 grade) The aluminium composite panel cladding sheet shall be coil coated with kynar 500 based PVDF/Lumiflon based fluropolymer resin (having 70:30 ratio of PVDF and acrylic) coating of approved colour and sg=hade on top face and polymer (service) coating of bottom face as specified using stainless steel screws,nuts,bolts,washers,cleats,weather silicon sealent,backer rods etc .overall weight of the ACP shall not be less than 7.5 Kilogram/ One Square Metre)The Anchoring / Bracing of the Structural Glazing to the RCC Beams/ Columns shall be done for structural glazing at site with Heavy duty 6mm thick M.S. Brackets of approved design with hot dip galvanized minimum 100 microns thick or Pure Polyester plain color Powder Coated of minimum 60 microns. Aluminum shims of various thicknesses as may be required shall be provided behind the brackets to adjust the beam level variations possible at site, or extended brackets duly designed as per design criteria of required size as per site requirements. INFRASTRUCTURE WORK

79.08

-

-

... More
Providing Heavy Duty Fibre Glass Reinforced Plastic Temporary Barricade of 1.75 m hight, with base width of 430 mm as a provision to accept water ballasting of 101 Itrs-110 Ltrs approx. and arrangement for traffic diversion such as traffic signals during construction at site, for day and night as per requirement. The raw material shall be UV stabilized Linear Low Density Polyethylene and should meet the requirements stipulated in standard IS: 10146-1982, IS:10141-1982 and should also comply to FDA:CFR Title 21.177.1520. Olefin Polymers , with specific FRP Grade 300-104 reinforced during moulding process to the permissible extent for improved impact strength. Qualification Criteria: For qualifying the sample , few tests shall be performed at Government Lab OR NABL Accredited Lab on Site Safety Fence sample, failure or deviations in test results of sample shall be disqualified.The tests and qualifying results are as under, (a) tensile strength at yield by ASTM D 638 =20.93 mPA, (b) Elongation at break ASTM D 638 = 121.66 mPA (c) Flexural Modulus ASTM D 790 = 633.76 mPA (d) Izod Impact Strenth (Notched) ASTM D 256 = 4.41Kilogram/ One Square Metre (e) Izod Impact Strenth (Un- Notched) ASTM D 256 = 67.04Kilogram/ One Square Metre (f) Drop Impact strength 25KilogramLoad from 1 m, 2 m & 5m height the weight of empty single Rotomoulded Plastic Barricade without water ballasting shall be 34 Kilograms approx. & total weight after water allasting shall be 135 Kilograms -140 Kilograms +/- 5 Kilograms (tolarance)The main Barricade body of hight 1750 mm approx is connected with the Extension body through 4 set of nut bolt washers .extenstion body through 4 set of nut bolt washers. Extension body is designed with 9 Nos kiss offs on rear side; the dimension of Extension body are 1500 mm (length),70 mm (width),250 mm (effetive height after fixing ) & dimension of its male collarare 1420 mm (length),25 mm (width),30 mm approx ( height), it is inserted in U groove provisioned on top of main body Barricade Model for interlconnecting.the minimum thickness of all over surface of plastic barricaed shall be 5 mm +/- 20%.the rear bottam shall have to provision to fix two brackets at both end in corner for anchoring purpose .each rear bracket is constructed through rod of Dia.60 mm with curvature welded with MS strip of 3 mm thick ,50 mm width and 90 mm length at its top and base ,effective bracket shall be 410 mm approx. the anchoring e) Site Safety Fence (2.00 Mtrs(H)) (Efficient Substitution to sheet Metal Barricade) , Empty Weight : 17.00 Kilogram/ Rgm,Weight Full : 70.00 Kilogram/ Rgm approx. (After Water / Sand Filling)INFRASTRUCTURE WORK

550

-

-

... More
Providing , laying and fixing ,jointing Eco- drain 160 mm SN 4 Nu- Drain UPVC pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees , coupler, etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated materialetc. complete.OPD BUILDING

825

-

-

... More
Providing , laying and fixing ,jointing Eco- drain 200 mm SN 4 Nu- Drain Upvc pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees tees, coupler etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated materialetc. complete.OPD BUILDING

4400

-

-

... More
Providing , Laying and fixing, jointing Eco Drain 315 mm SN-04 Nu-Drain Upvc pipe or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 & 16098 with fittings such a bends, tees, coupler, etc. jointing with rubber lubricant, including necessary excavation, trench refilling with selective excavated material etc.complete.OPD BUILDING

1500

-

-

... More
Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 450mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.SUBSTATION/ OPD BUILDING

889.3

-

-

... More
RWH - Shallow Percolation Pit providing, constructing 2.0m deep shallow depth percolation pit comprising of 1.0m dia pre-cast RCC rings, 300mm thick side filling around outside of RCC rings (annular space) with 40mm size boulders including filling of percolation pit up to 0.5m depth (from bottom up) with 25-75mm clean washed gravels followed by 0.5m depth of 10-25mm of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) media layer including covering with RCC slab, manhole frame & cover, PVC rungs etc. including arrangement for inlet & outlet pipe, excavation & backfilling as shown in the drawing. The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge OPD BUILDING

2

-

-

... More
Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 600mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.OPD BUILDING

939.3

-

-

... More
Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 800mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.OPD BUILDING

847

-

-

... More
Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 900mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.OPD BUILDING

1086

-

-

... More
Providing and fixing H.D.P container one piece moulded water tank made out of low density polythyler and built corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity above 1000 to 20,000 litres WARD

120000

-

-

... More
Grab bars-Providing SS grab bars set for accessible toilets comprising of 4 nos. Grab bars as specified below.(1 nos. wing grab bar + 1 nos. L shaped grab bar + 2 nos. straight grab bars = 1 typical set) 27a) Swing grab bar (1 NOS) Providing a S.S. 304 SWING HANDICAP GRAB BAR - 700 mm and of DIA: 32MM and thickness 1.5mm of the roved brand and make. 27b) L Shaped grab bar (1 NOS) Providing S.S. 304 L SHAPED DISABLED GRAB BAR of IZE-600MM (H) X 600MM (D) and 32MM DIA. and thickness mm of the approved brand and make. 27c) Straight grab bar (2 NOS) Providing S.STEEL 304 GRAB RAIL (600 MM),32MM DIA. and thickness 1.5mm of the approved brand and make.OPD BUILDING

24

-

-

... More
WARD Second Floor

10

-

-

... More
Third Floor

10

-

-

... More
Fourth Floor

10

-

-

... More
Providing supply and installation of Curtain Wall glazing with cover and pressure plate system in 8 mm toughened reflective Glass Glazing in 2.10 mm thick anodized aluminium curtain wall pipe section of size 101.60mm X 57 mm with cover plate and pressure plate & including 8 mm toughened glass with the help of gasket,anodizing,labour charges,silicon,anchor fastnerof hilti,m.s bracket complete fitting.The Anchoring / Bracing of the Structural Glazing to the RCC Beams/ Columns shall be done for structural glazing at site with Heavy duty 6mm thick M.S. Brackets of approved design with hot dip galvanized minimum 100 microns thick or Pure Polyester plain color Powder Coated of minimum 60 microns. Aluminum shims of various thicknesses as may be required shall be provided behind the brackets to adjust the beam level variations possible at site, or extended brackets duly designed as per design criteria of required size as per site requirements. All screws, bolts, nuts and washers used in the Structural Glazing system shall only be in stainless steel of grade 316. Adequate anchoring to the structure shall be provided, fasteners shall be of HILTI/Fisher or equivalent make. The gaps upto 10-15 mm between the masonry/RCC and the peripheral mullions and transoms shall be sealed by inserting Bond Breaking backer rod and by application of weather silicone sealant both from outside and inside; wherever the gaps are expected to be more than 10-15mm shall be sealed by providing and fixing of 1mm thick aluminium sheet flashings in approved design profile and pure polyster powder coating colour of miniumum 60 microns to match the masonry finish.OPD BUILDING

770

-

-

... More
Providing Supplying & position aluminium fins of 4000 x 150x 100 mm with special locking system designed by Elegance aechitectural or Equivalent products supported by 50x50mm L- Angle with pre- punchated hole as per approved gap horizontal carriers both, having thickness of 1.2 mm and a clear gap of 150mm between vertical members as per pattern, cooice of colour, finish, etc. as shown in approved drawings and as instructed by site incharge,Rate shall be inclusive of supply & fixing using 1mm thick L-clit of dim. 50mm x 50mm x 50mm & SS-screws),application of powder coaing.cuting, making,fixing,transportation,loading,unloading,fiting,shifting,saftey precautions etc. all complete. spec.No.As directed by engineer in charge.OPD BUILDING

1144.85

-

-

... More
WARD Second Floor

112.5

-

-

... More
Third Floor

112.5

-

-

... More
Fourth Floor

112.5

-

-

... More
Providing and fixing SS-304 strips of size 280mm x 35mm of the approved brand and make inside the building on all floors in corridors, lobbies level differences etc. as per accessibility standards and as per the installation instructions prescribed by the manufacturer, using the necessary adhesive including finishing work up to the satisfaction of the engineer in charge complete.OPD BUILDING

200

-

-

... More
Design, supply, fabrication and fixing of SS, non glare Signage board (2 ft. x 2 ft.- 1 One Number) for the accessible parking, as per the approved design and make, having 1.2mm thick SS non glare base plate and Grade 2/ Grade 1 Braille (raised dots)to be etched/ engraved and be raised 0.5mm above base plate and Upper Case San Serif words and Universal Accessibility Symbol to be etched/ engraved and signage to be installed at a height of 2100mm from the ground level using a post of MS hollow square section (50mm x 50mm) as per the installation procedure specified by the manufacturer and as per accessibility standards and up to the satisfaction of the engineer in charge.OPD BUILDING

200

-

-

... More
Providing and erecting chain link fencing 1.6 M. height with G.I. chain link of size 50 x 50 mm, 8 gauge thick and fixed 75 mm above ground level on vertical M.S. Angles of 40 x 40 x 6 mm size, includind excavating pits for foundation and embedded in C.C. block of 1:4:8 mix of size 450 x 450 x 670 mm. at 1.75 M. c/c with iron bar 16mm dia as hold fast including welding link with angle frame at 30 cm c/c with nuts and bolts and horizontal M.S. Angles at top and bottom of 25 x 25 x 5 mm size and vertical M.S. flat 35 x 5 mm and 25 x 5 mm horizontal including cross support of 40 x 40 x 6 mm angles both side at every corner or bend embedded in concrete blocks of 1:4:8 of size 450 x 450 x 670 mm including 3 coats of oil painting etc. complete.SUBSTATION

20

-

-

... More
Excavation for roadway in earth, soil of all sorts, sand, gravel or soft murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50m. and spreading for embankment or stacking as directed. By Manual Means. ( Item used only when Quantity is below 10 INFRASTRUCTURE WORK

2164.98

-

-

... More
Excavation for catch / side water gutter in all sorts of soils to the specified section including stacking the excavated stuff in a regular bund and disposing of unsuitable or excess stuff as directed all sorts of soils.INFRASTRUCTURE WORK

1623.74

-

-

... More
Watering and compacting of embankment formed of materials obtained from the road cutting within a lead of 50 m, not less than 97 % of standard Proctor density after laying them in layers of 20 cm. to 30 cm. with vibratory roller.INFRASTRUCTURE WORK

541.25

-

-

... More
Conveying materials obtained from road cutting including all lifts, laying in layers of 20cm to 30cm. breaking clods, dressing to the required lines, curves, grades and section, watering and compacting to not less than 97% of standard Proctor density for a lead of over 50m. to 300m. inclusive from the site of excavation to the site of deposition as directed.INFRASTRUCTURE WORK

541.24

-

-

... More
Conveying materials obtained from road cutting including all lifts, laying in layers of 20cm. to 30cm. breaking clods, dressing to the required lines, curves, grades and section, watering and compacting to not less than 97% of standard proctor density for a lead of 300m. to 500m. inclusive, from the site of excavation to the site of deposition as directed.INFRASTRUCTURE WORK

541.24

-

-

... More
Providing earth work in embankment with approved materials obtained from other sources upto lead of 50m. including all lifts, laying in layers of 20cm. to 30cm. thickness breaking clods, dressing to the required lines, curves, grades & section, watering and compaction with vibratory roller with V-Sat attachment to achieve not less than 97 % of standard proctor density etc. complete ( Material obtained from Other sources)INFRASTRUCTURE WORK

865.99

-

-

... More
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader/ Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - I Material INFRASTRUCTURE WORK

649.49

-

-

... More
Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate ( natural sand/ VSI grade finely washed crushed sand) conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, , cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor /by suitable means as approved by Engineer-in- charge , compacting with vibratory roller, finishing, curing and including preparation of sub-grade surface if required etc. complete. with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete.INFRASTRUCTURE WORK

433

-

-

... More
Providing and laying in-situ M30 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement , coarse and fine aggregate( natural sand/ VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver,compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6m X 0.6m centre to centre, admeasuring 80 mm at bottom and 40 mm at top with depth of 75mm and maintaining the same throughout curing period by any other method approved by Engineer-in-charge. with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete.INFRASTRUCTURE WORK

1298.99

-

-

... More
Providing and fixing in position TMT FE 500, 25mm dia dowel bars precoated with anticorrosive epoxy paint of required Dia. 60 cms. Long and at 30.00 cm. C/C and wherever directed including handling, straightening, necessary cutting supported by TMT FE 500, chairs with proper alignment by using properly designed assembly of Bulkheads lubricating half length with bituminous paint as directed etc. complete.INFRASTRUCTURE WORK

2422

-

-

... More
Providing and fixing in position TMT FE 500, tie bars precoated with anticorrosive epoxy paint of 12 mm dia. 70 cms.long and at 30.00 cm. C/C and wherever directed including handling, straightening wrapping with paper of approved quality for half length, necessary cutting, handling, straightening , supported by assembly of TMT FE 500, chairs with proper alignment etc. complete..INFRASTRUCTURE WORK

2422

-

-

... More
Providing to contraction joints polysuphide sealent (Pouring grade) confirming to BS : 5212 - 1989 into sawed groove widened at top for sealent reservoir of specified size and shape as per detailed drawing including fixing Polyethylene foam backer rod of required diameter (appraox. 25% larger than the initial 3 mOne Metric Tonneo 4 mm. joint) overlaid with bond breaking tape as per detailed drawing. Item includes cleaning the joints with water jet / air compressor and allowing joint to become thoroughly dry before sealent is applied and applying primer. (A) Contraction and longitudinal joints (15 mm. deep x 8 mm.wide)INFRASTRUCTURE WORK

14433

-

-

... More
Providing and laying 125 micron Low Density Polyethylene (LDPE) sheet confirming to IS 3395 : 1997 below concrete pavement including all materials and labour complete.INFRASTRUCTURE WORK

4329.96

-

-

... More
Providing and fixing factory made Hydraulically pressed Mechanically vibrated and compacted precast inter locking cement concrete paving blocks 100MM thick in M-50 grade of approved size and shape for City streets and roads with high volume/ heavy traffice as specified and as per IS 15658:2006 including cost of all materials, manufacturing, curing, transportation of blocks to work site including loading, unloading and stacking as directed, laying paving blocks in position over prepared bed of natural sand / crushed sand of 50 mm thickness including necessary excavation in all stratas, spreading blindge of fine sand over the prepared bed, compacting blocks by plate vibrator etc. complete.INFRASTRUCTURE WORK

2164.98

-

-

... More
Providing and casting in situ or precast tapering R.C.C. M-20 Semi Barrier type Kerb with gutter ( as per IRC 86 1983) embedded 125mm below ground level over M-10 PCC finished neatly with C.M. 1:2, setting the same in C.M. 1:2, including the required excavation in any strata and removing the excavated stuff any where in city and redoing the surface as specified and directed by Engineering In-charge. Using Concrete Batching and Mixing Plant INFRASTRUCTURE WORK

721.66

-

-

... More
Providing and casting in situ or precast tapering R.C.C. M-20 Mountable type Kerb with gutter ( as per IRC 86 1983) embedded 125mm below ground level over M-10 PCC finished neatly with C.M. 1:2, setting the same in C.M. 1:2, including the required excavation in any strata and removing the excavated stuff any where in city and redoing the surface as specified and directed by Engineering In-charge. Using Concrete Batching and Mixing Plant INFRASTRUCTURE WORK

721.66

-

-

... More
Painting Line, Dashes, Arrows etc on Roads in two coats on new work with ready mixed road marking paint confirming to I.S. 164 on Bituminous surface including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control (Over/Upto cm wide) (MORTH-803) --             Surface INFRASTRUCTURE WORK

4329.96

-

-

... More
Godrej mamke Executive Table Model:- Finess Table Size:- 1500 W x 750 D x 750 H Specification:- Table - 5026 size shall be 1500 Width mm x 750 Depth mm x 740 Height mm .Table top shall be 25 mm thick plain particle board (PPB) Clad with 0.6 mm thick post formed laminate and 1 mm thick backing laminate (bdl) .Flat edge Duly sealed with 2 mm thick PVC beading.The modesty shall be 18 mm thick plain particle board ( ) PPB Clad with 1.0 mm thick decorative laminate (DL) on both sides. Edge Sealed with 2 mm thick PVC beading.The manufacturer shall have Inhouse manufacturing facility and shall have membership/ certification from ISO 9001-QMS, ISO14001 EMS, OHSAS 18001,IIID,& BIFMA shall be as directed by Engineer in charge.OPD BUILDING- Ground Floor / First Floor

12

-

-

... More
Godrej make High Back Chair Model:- Bravo High Back Specification:- Seat / Back Assembly :- The seat and back are made up of 1.2 + / - 0.1 cm thick hot –pressed plywood measured as per QA method described in OCP-QLTA- PA 14-18 and upholstered with fabric upholstery covers and moulded polyurethane foam. The back foam is designed with contoured lumbar support for extra comfort. The seat has extra thick foam on front edge to give comfort to popliteal area.The chair is available in three models:- High Back Size :- 47.5 cm (W) x 69.5 cm (H) Seat Size :- 47.0 cm (W) x 48.0 cm (D) High Resilience (HR) Polyurethane Foam: - The HR polyurethane foam is moulded with density = 45+ /- kg/m3 and hardness load 16 + /- kgf as per IS: 7888 for 25% compression. Armrests: - The one Piece armrest are injection moulded from black Co-polymer Polypropylene. Centre Tilt Synchro Mechanism: - The mechanism is designed with following feature:-360 revolving type, Upright position locking, Tilt tension adjustment,Seat / Back tilting ratio of 1:3. Tubular Frame: - The powder coated (DFT 40-60 microns) tubular frame is cantilever type & made of 0 2.54 + / - 0.03 cm x 0.2 +/- 0.016 cm thk. M.S. ERW Tube. Pneumatic Height Adjustment: - The pneumatic height adjustment has an adjustment stroke of 12.0 + / - cm. Telescopic bellow Assembly:- The bellow is 3 piece telescopic type and injection moulded in black polypropylene. Pedestal Assembly:- The pedestal is injection moulded in black 33% glass-filled Nylon – 66 and fitted with 5 nos. twin wheel castors. The pedestal is 66.3 + /- 0.5 cm. Twin Wheel Castors:- The twin wheel castors are injection moulded in Black Nylon. The manufacturer shall have Inhouse manufacturing facility and shall have membership/ certification from ISO 9001-QMS, ISO14001 EMS, OHSAS 18001,IIID,& BIFMA shall be as directed by Engineer in charge.OPD BUILDING- Ground Floor/ First Floor

12

-

-

... More
Godrej make Visitor Chair Model:- Premier Visitor Chair with Armrest (7112R) Specification - The seat and back shall be made up of 1.2 ±0.1cm. thick hot pressed plywood measured as per QA method described in OCP-QLTA-P14-18 and shall be upholstered with fabric and moulded Polyurethane foam with PVC lipping all around. The back foam shall be designed with contoured lumbar support for extra comfort. The dimensions of the back shall be 49.0 cm. (W) x 47.0 cm and of seat shall be 49.0 cm. (W) x 44.0 cm. (D). The HR Polyurethane foam shall be moulded with density= 45 ±2 kg/m3 and Hardness load 16 ± 2 kgf as per IS:7888 for 25% compression. The armrest tops shall be injection moulded from black Polypropylene. They shall be fitted to tubular armrest supports made of dia 2.54 ±0.03cm. x 0.16 ±0.0128cm.thk. M.S. E.R.W. tube and black powder coated ( DFT 40-60 microns ). The tubular armrest supports should hold together the seat and back. The tubular frame shall be cantilever type & made of 0 2.54±0.03cm. x 0.2 ±0.016cm.thk. M.S. E.R.W. tube and black powder coated (DFT 40-60 microns). Overall Dimensions of Chair shall be Seat Height - 43.0cm, Height - 80.0cm, Width & Depth of Chair as measured from pedestal - Width-55.0 cm and Depth-61.0 cm. The manufacturer shall have Inhouse manufacturing facility and shall have membership/ certification from ISO 9001-QMS, ISO14001 EMS, OHSAS 18001,IIID,& BIFMA shall be as directed by Engineer in charge. (Note:- Standard packing of 2 Nos Order should be in multiple of 2 Nos) OPD BUILDING- Ground Floor/ First Floor

24

-

-

... More
Godrej make Office Table Model :- Enterprise 1500 Table without CPU Hanger Size:- 1500 W x 750 D x 728 Ht mm Specification:- upplying & placing in position of Godrej/Delfom/Herman Miller Enterprise 1500 Table without CPU Hanger size shall be 1500 Width mm x 750 Depth mm x 728 Height mm. Top shall be 18 mm thick Pre laminated particle board all work surface edges shall be having duly sealed with 2 mm thick PVC edgebanding. Understructure Modesty Panel 18 mm thick Pre laminated particle board . The Rectangular frame shall be fabricated component in 1.2 mm thick CRCA , Finish : powder Coat( epoxy polyster) . Leg shall be fabricated component in 38 mm x 25 mm 1.2 mm thick MS ERW ATube ,finish powder coat ( epoxy polyster).The plastic cap for cable travel shall be injection moulded polypropylene and leveler glide for shall be nylon 6 & MS bolt. The storage shall be having shell and drawer tray 0.6 mm thick CRCA Finish powder coat (epoxy polyster) plus the drawer front shall be 0.8 mm thick CRCA Finish powder coat (epoxy polyster) plus lock with 10 lever and handle and leveller. The wire management shall be horizontal wire carrier 0.7 mm thick CRCA Finish powder coat (epoxy polyster) and vertical wire carrier 0.8 mm thick CRCA Finish powder coat (epoxy polyster) . The manufacturer shall have Inhouse manufacturing facility and shall have membership/ certification from ISO 9001-QMS, ISO14001 EMS, OHSAS 18001,IIID,& BIFMA shall be as directed by Engineer in charge.OPD BUILDING- Ground Floor/ First Floor/Second Floor /Third Floor/ Fourth Floor

128

-

-

... More
Godrej make Mid Back Chair Size:- Bravo Mid Back Chair Specification:- Seat / Back Assembly :- The seat and back are made up of 1.2 + / - 0.1 cm thick hot –pressed plywood measured as per QA method described in OCP-QLTA-PA 14-18 and upholstered with fabric upholstery covers and moulded polyurethane foam. The back foam is designed with contoured lumbar support for extra comfort. The seat has extra thick foam on front edge to give comfort to popliteal area. Mid Back Size :- 47.5 cm (W) x 58.0 cm (H) ,Seat Size :- 47.0 cm (W) x 48.0 cm (D)High Resilience (HR) Polyurethane Foam: - The HR polyurethane foam is moulded with density = 45+ /- kg/m3 and hardness load 16 + /- kgf as per IS: 7888 for 25% compression.Armrests: - The one Piece armrest are injection moulded from black Co-polymer Polypropylene. Centre Tilt Synchro Mechanism: - The mechanism is designed with following feature:- 360 revolving type, Upright position locking, Tilt tension adjustment, Seat / Back tilting ratio of 1:3 Tubular Frame: - The powder coated (DFT 40-60 microns) tubular frame is cantilever type & made of 0 2.54 + / - 0.03 cm x 0.2 +/- 0.016 cm thk. M.S. ERW Tube. Pneumatic Height Adjustment: - The pneumatic height adjustment has an adjustment stroke of 12.0 + / - cm. Telescopic bellow Assembly:- The bellow is 3 piece telescopic type and injection moulded in black polypropylene. Pedestal Assembly:- The pedestal is injection moulded in black 33% glass-filled Nylon – 66 and fitted with 5 nos. twin wheel castors. The pedestal is 66.3 + /- 0.5 cm. Twin Wheel Castors:- The twin wheel castors are injection moulded in Black Nylon. . The manufacturer shall have Inhouse manufacturing facility and shall have membership/ certification from ISO 9001-QMS, ISO14001 EMS, OHSAS 18001,IIID,& BIFMA shall be as directed by Engineer in charge.Ground Floor First Floor Second Floor Third Floor Fourth Floor

126

-

-

... More
Godrej make Visitor Chair Model:- Premier Visitor Chair with Armrest (7112R) Specification - The seat and back shall be made up of 1.2 ±0.1cm. thick hot pressed plywood measured as per QA method described in OCP-QLTA-P14-18 and shall be upholstered with fabric and moulded Polyurethane foam with PVC lipping all around. The back foam shall be designed with contoured lumbar support for extra comfort. The dimensions of the back shall be 49.0 cm. (W) x 47.0 cm and of seat shall be 49.0 cm. (W) x 44.0 cm. (D). The HR Polyurethane foam shall be moulded with density= 45 ±2 kg/m3 and Hardness load 16 ± 2 kgf as per IS:7888 for 25% compression. The armrest tops shall be injection moulded from black Polypropylene. They shall be fitted to tubular armrest supports made of dia 2.54 ±0.03cm. x 0.16 ±0.0128cm.thk. M.S. E.R.W. tube and black powder coated ( DFT 40-60 microns ). The tubular armrest supports should hold together the seat and back. The tubular frame shall be cantilever type & made of 0 2.54±0.03cm. x 0.2 ±0.016cm.thk. M.S. E.R.W. tube and black powder coated (DFT 40-60 microns). Overall Dimensions of Chair shall be Seat Height - 43.0cm, Height - 80.0cm, Width & Depth of Chair as measured from pedestal - Width-55.0 cm and Depth-61.0 cm. The manufacturer shall have Inhouse manufacturing facility and shall have membership/ certification from ISO 9001-QMS, ISO14001 EMS, OHSAS 18001,IIID,& BIFMA shall be as directed by Engineer in charge. (Note:- Standard packing of 2 Nos Order should be in multiple of 2 Nos)Ground Floor First Floor Second Floor Third Floor Fourth Floor

282

-

-

... More
Godrej make Almirah Model: Storwel Plain Size: 1981 H x 916 W x 486 D Specifcation:- Storwel plain shall have an overall size of 916mm(W)x486mm(D)x1980mm(H) with welded construction. It should have the shelf thickness of 0.7 mm, Back thickness of 0.8mm, Door thickness of 0.8mm (high yield strength) and all other components shall have a thickness of 0.9mm. These components shall be made of CRCA ‘D’ grade high yield strength as per IS:513. The Storwel Plain should have a Mazak handle and Three way locking mechanism with Shooting Bolts. It should have a height wise adjustable shelf mounting which shall have a Uniformly Distributed Load Capacity of max 40 Kg. It should also have a M10 Screw type Leveller with Hex plastic base. The finishing shall include Epoxy powder coated to the thickness of 50 microns (+/- 10). Plenty of colour options and shelving options shall be available. The manufacturer shall have Inhouse manufacturing facility and shall have membership/ certification from ISO 9001-QMS, ISO14001 EMS, OHSAS 18001,IIID,& BIFMA shall be as directed by Engineer in charge.Ground Floor First Floor Second Floor Third Floor Fourth Floor

152

-

-

... More
Godej make Computer Table Model:- Companion C2 Size:- 1200 W x 600 D x 750 H Ground Floor First Floor Second Floor Third Floor Fourth Floor

50

-

-

... More
Library Area Table @ 1350Lx750Dx750HT Providing & Fixing of FREE STANDING TABLE @ 1350Lx750Dx 750HT:- TOP to be made of 25 mm thick Prelaminated particle board with PVC edge band, BENT LEG to be CHROME FINISH as per drawing.Ground Floor First Floor

72

-

-

... More
12 Seater Reading Table for Library @ 3600Lx1200Dx750HT Providing and Fixing 12 Seater Reading Table for Liberary @ 3600Lx1200Dx750HT Top: made from 25 mm Prelaminated Particle board. All edges are covered by 2 mm. Thk. PVC edge bands glued by hot melt glue applied by auto edge banding machine. Gable Ends : made from 25 mm Prelaminated Particle board. All edges are covered by 2 mm. Thk. PVC edge bands glued by hot melt glue applied by auto edge banding machine. Modesty panel : Made from 18mm both side prelaminated particle boards.All edges are covered by 0.8mm PVC edge bands glued by hot melt glue applied by auto edge banding machine.Ground Floor First Floor

4

-

-

... More
Godrej make Storwel with Glass Model:- Glass Door Storwel Specification:- Glass Door Storwel shall have an overall size of 916mm(W)x486mm(D)x1980mm(H) with welded construction. It should have shelf thickness of 0.7 mm, Back thickness of 0.8mm, Door thickness of 0.8mm (high yield strength) and all other components shall have a thickness of 0.9mm. These components shall be made of CRCA ‘D’ grade high yield strength as per IS:513. The glass door storwel shall have a brass handle and a 2 way locking mechanism with shooting bolt . It should have a height wise adjustable shelf mounting which shall have a Uniformly Distributed Load Capacity of max 40 Kg. It should also have a M10 Screw type Leveller with Hex plastic base. The finishing shall include Epoxy powder coated to the thickness of 50 microns (+/- 10). Plenty of colour options and shelving options shall be available.. Product should be Green Building Compliant Such as UL Green Guard, CII Green Pro and GRIHA.All metal components should be of MS CRCA of Tata Steel or Sail or Jindal Steel and pre treated with zinc phosphating in 8 tank porcess and then powder coated with epoxy polyster powder coating of Kansai Nerolac Paints or Asian Paints. Test reports conforming to relevant ISI codes for raw material, powder coating/ anodizing with anti-rust surface treatment inclusive of method of tests i.e. Dry film/ coating thickness, Finish, Gloss 60°, Colour retention, Scratch hardness, Impact resistance test, DFT measurement, Salt spray test, Adhesion Cross cut test. Goods should be supplied in knocked down construction and should have low VOC emission. The manufacturer shall have Inhouse manufacturing facility and shall have membership/ certification from ISO 9001-QMS,ISO14001 EMS, OHSAS 18001,IIID,& BIFMA shall be as directed by Engineer in charge.Ground Floor First Floor

80

-

-

... More
Godrej Multipurpose Chair Model:- Unwind with arms M/S Understructure with Arm Rest Sprcification:- Chair Back: (W) 51.6cm x (H)40.5cm, Seat : (W)52.5cm x (D)53.2cm Overall Dimensions of Chair Seat Height - 45.0 cm. Height - 84.5cm. Width-52.5 cm and Depth- 55.8 cm." The Seat and Back should be made up of injection moulded indoor grade PolyPropylene compound. SEAT SIZE : 52.5 cm. (W) x 53.2 cm. (D) BACK SIZE : 51.6 cm. (W) x 40.5 cm. (H) The powder coated ( DFT 50±10 microns ) welded tubular frame should be made from 0 2.22 ± 0.03 cm x 0.16 ± 0.0128 cm and 3.5 ± 0.03 cm x 1.5 ± 0.03 cm x 0.16 ± 0.0128 cm MSERW tube. The shoes should be made of indoor grade PolyPropylene compound and snap fitted with tubular frame. The Armrest should be made of indoor grade PolyPropylene compound and assembled over the tubular frame.Ground Floor First Floor

624

-

-

... More
Sofa Set 3+1+1 Providing & fixing Sofa Set 3+1+1 Brown and Cream leather DIMENSION Length: 182.5 (cms) Breadth (cms): 100 (cms)Height (cms): 100 (cms) Weight (Kilograms): 66 (Kilogram) Seating Capacity: Five Seat Ground Floor First Floor Third Floor

42

-

-

... More
Tea Table 900mm X 750mm X 450mm for m.s. ante chamber Providing And Fixing Of Tea Table 900mm X 750mm X 450mm With 12mm Thick Colour Eitched Tempered Glass With Bevelled Drawing Made Out Of 18mm Thick Waterproofing Ply. The Outer Laces To Be Finished With High Quality 4 Mm Thik Veneer Or 1 Mm Thik Mica Etc.Ground Floor First Floor Third Floor

42

-

-

... More
Public Seating Chair. - 3 Seater Providing and Fixing 3 seater Public seating chair made of complete metal with Legs in Crome finish and seates in silver powder coating finish.Ground Floor First Floor Second Floor Third Floor

304

-

-

... More
Providing & fixing in position Stage flooring Made from 18mm plywood 1200 x 2400 & 18mm Teakwood planks 100 x 800 having tongue & grove on Sal-wood frame of 50 x 100 at 600mm c to c on stage surface including cost of required Cut-Outs, decorative mouldings / finishing-items / polish etc., as per Architectural & Acoustical Design & Instructions & Complete in all aspects. .including all materials labour,finishing etc complete Ground Floor First Floor

60

-

-

... More
Godrej make Desklet Chair Model:- Uniwnd Desklet Chair Specification:- MS understructure of The seat and back are made injection moulded high impact strenght polypropylene polymer compound with indoor graade UV Resistance. The Powder coated (DFT50+ microns) welded Beam M.S. Structure is made from 2.22 + 0.03 cm x 0.16+/- 0.03 x 0.16 +/-0.0128 cm and 3.5 +/- 0.03 cm x 1.5 cm c 0.16 +/- 0.0128 Desklet - The "L" Shape Desket is made of 1.8+/- 0.05cm thk . pre - laminated Perticleboard with 0.2+/- 0.05 cm thk injection polypropylene polymer all around. Desklet has Front & Back adjustment of 4.4 +/- 0.5 cm. ( outher Dimension - 31.5+/- (W)x 47.0+/- 0.1 cm (D). Paper Tray – The paper trey is made of 0.4 +/- 0.05 cm. M.S. rod which is spot welded to form a mesh type Structure. It is powder coated size - 40.1 W x 36.1 D x 22.0 cm H. The manufacturer shall have Inhouse manufacturing facility and shall have membership/ certification from ISO 9001-QMS, ISO14001 EMS, OHSAS 18001,IIID,& BIFMA shall be as directed by Engineer in charge.Ground Floor Second Floor Third Floor Fourth Floor

504

-

-

... More
Godrej make Recta 4 seater workstation (Piece given 1 seater per person seating workstation) Model - Recta Workstation wish spine Fin size 1200 W X 600 D Providing and placing 52.4mm Thick 1200 mm high panels Along Spine in wish system with Combinetion of metal Raceway at Botton. Two intermediat Fabric, Top Tile Fabric Tackble, White board Providing powder coated legs providing 22.8 mm Thick pannel with Bottom Metel screen Invermediate Laminated Csreen & Top Screen in Fabric Magnetic Finish Ground Floor/First Floor/Third Floor

20

-

-

... More
Godrej make Desk cum Bench Model:- Scholar 1048 W Desk Cum Bench Scholar 1048 W Desk Cum Bench size shall be 1048 Width mm x 895 Depth mm x 750 Height mm . Top & Seat Panel shall be 18 mm thick PLB(pre - laminated board ) with Back panel shall be 18 mm thick PLT . The Understructure shall be MS SQ tubes of size 25.4 mm x 1.2 mm Plus there shall also be a storage Shelf .Ground Floor/First Floor

160

-

-

... More
Godrej make Revolving Stool. Model: Revolving Stool Mch Ht Adj + back Hi Base (FUS1M4HC) Specification:- The seat shall be made up of 1.2±0.1cm thick flat plywood measured as per QA method described in OCP-QLTA-P14-18 and with moulded Polyurethane foam and are upholstered with replaceable synthetic leather covers. The dimensions of Seat shall be Diameter 40.0 cm and Adjustments are 360° Revolving type. The back foam shall be designed with contoured Lumbar support for extra comfort. The upholstery shall be available in synthetic leather. The dimensions of Back shall be 45.0 cm (W) covered with polyurethane foam. The HR polyurethane Foam shall be moulded with density = 45 +/-2 kg/m3 and Hardness load 16 ± 2 kgf as per IS:7888 for 25% compression. The manual height adjustment shall be very easy to operate with a help of a knob. It should be easily locked at the most comfortable position. The five-prong pedestal shall be fabricated from 0.2 ± 0.02 cm thick HR sheet ( IS : DD 1079/HR ), powder coated ( DFT 40-60 microns ) and shall be fitted with an injection moulded black Polypropylene Hub Cap and 5 nos. twin wheel castors. The Pedestal shall be 55.0±0.5cm pitch- circle-diameter(65.0±-1.0cm with castors), Circular-foot-ring of dia 52.0±0.2cm shall be made up of dia 1.9±0.2 x 0.12±0.0096cm thk MS ERW Tube for foot support in High-base stool.The twin wheel castors shall be injection moulded in Black Nylon. Overall dimensions shall be Width- 65.0cm, Depth- 65.0 cm, Height- 88.0 to 99.5 cm, Seat Height- 67.0 to 78.5 cm.-Ground Floor

26

-

-

... More
Providing Godreg or equivalent make Fowler bed. Two-functional fixed height hospital bed designed for daily requirements in general ward areas and special rooms of healthcare facilities. It has two functions – backrest and knee rest which can be raised or lowered manually with the help of crank mechanism. Functions Backrest movement: 65°, Legrest Movement: 30°. Bed dimensions: (L) 2100 mm x (W) 912 mm x (H) (mattress support platform) 605 mm, Overall Height with Head baord : 935 mm in MS ERW tubes with epoxy-powder coated finish having weight capacity Max Patient weight: 120 kg, Safe Working Load (SWL): 155kg, 4-section platform lying surface, having castors of 125 mm dia, Single-wheel diagonal locking / leg shoes (Optional). Additional features Provision to put light IV pole on any of four corners of the bed, DVT on ratchet. Headbaord type PP blow-moulded headbaord with MS powder coated studs, SS exo-skeleton with PLT panel, MS Tubular Powder Coated Head/Foot Board. Siderails having 3-Bar siderail, funstions MS 3 bar siderail with pull & turn mechanism, Dimensions (L) 1340 mm x (W) 111 mm x (H) 492 mm, Height over lying surface: 330 mm, Standards & Certifications : IEC 60601–2–52* – General Safety for Medical Beds, ISO 13485 – Quality Management System-Second Floor/Third Floor/Fourth Floor

764

-

-

... More
Electric work:- INTERNAL ELECTRIFICATION:- Supplying and erecting HMS PVC conduit FRLS grade 20 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.

1565

-

-

... More
Supplying and laying HMS PVC conduit FRLS grade 20 mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.

3915

-

-

... More
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.

940

-

-

... More
Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.

2515

-

-

... More
Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.

560

-

-

... More
Supplying and laying HMS PVC conduit FRLS grade 32mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.

2255

-

-

... More
Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW

10016

-

-

... More
Supplying and erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW

10016

-

-

... More
Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW

5599

-

-

... More
Supplying and erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW

5599

-

-

... More
Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW

415

-

-

... More
Supplying and erecting mains with 1x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW

415

-

-

... More
Supplying and erecting mains with 2x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW

500

-

-

... More
Supplying and erecting mains with 4x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW

2145

-

-

... More
Supplying and erecting mains with 1x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW

2645

-

-

... More
Supplying and erecting mains with 4x10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW

105

-

-

... More
Supplying and erecting mains with 1x10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW

105

-

-

... More
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.

301

-

-

... More
Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete.

411

-

-

... More
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.

295

-

-

... More
Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.

411

-

-

... More
Supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete.

580

-

-

... More
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.

5

-

-

... More
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.

5

-

-

... More
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.

150

-

-

... More
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.

20

-

-

... More
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.

130

-

-

... More
Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/CW

1139

-

-

... More
Point wiring for ceiling fan concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/CW

182

-

-

... More
Point wiring for independent plug, concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No WG-PW/SW

177

-

-

... More
Point wiring for light/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/HW

816

-

-

... More
Point wiring for ceiling fan (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/HW

398

-

-

... More
Wiring for plug on board with Switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WG-PW/CW

354

-

-

... More
Supplying and erecting LED square / circular Max. 11 W down lighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 1200 Lumens, min. efficacy of 110 lumen/W, CRI80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD10%, p.f. 0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.

373

-

-

... More
Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD10%, p.f. 0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.

358

-

-

... More
Supplying and erecting LED square / circular Max. 25 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2750 Lumens, min. efficacy of 110 lumen/W, CRI80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD10%, p.f. 0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.

481

-

-

... More
Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI80, CCT upto 6500K, Beam Angle of 120 deg., THD10%, p.f. 0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty.

231

-

-

... More
Supplying and erecting anodized aluminium corridor / passage / mirror light LED fitting (2 feet) Max. 12W with high transitivity diffuser with min. system lumens output of 1200 lumens, min. efficacy of 100 lumen/W, CRI80, CCT upto 6000K, Beam Angle of 110 deg., Ripple5%, THD10%, p.f. 0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver with end caps on provided PVC Block / wooden board with 3 years warranty.

64

-

-

... More
Supplying and erecting CRCA powder coated corridor/passage light LED fitting (4 feet) Max. 17W with high transitivity diffuser with system lumens output of Min. 2000 lumens , min. efficacy of 120 lumen/W, CRI80, CCT upto 6500K, Beam Angle of 120 deg., Ripple5%, THD10%, p.f. 0.95, operating range of 120-270V, surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty.

395

-

-

... More
Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 300mm. 1400 RPM rust proof body & blades, wire mesh, duly erected, complete.

61

-

-

... More
Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of 28W having service ratio (CMM/W) of Min. 8 , PF0.9, THD10% without IR remote control/compatible speed regulator, Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF (Note : Item No. 2-10-22 reduce rate by 10% for BLDC fan without IR remote control or without speed regulator.) Rs. 3811 - Rs 381.1 (10%) = Rs. 3429.9

580

-

-

... More
Supplying and erecting fan hook box of 10 mm M.S. round bar bounded to the R.C.C. bars upto 50 mm length each side and pierced through a 16 S.W.G. thick aluminium/M.S. Bowl 100 mm dia. or equivalent square size and having depth upto 75 mm complete erected with duly painted by one coat of red oxide paint and two coats of paint erected in position and without any leakage of slurry of cement concrete on either side of the box and positioned to the bottom level of the slab.

580

-

-

... More
Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire.

580

-

-

... More
Supplying, erecting, testing and commissioning of 10kVA capacity online pure sine wave, with backup time of ....... hrs. PWM & IGBT based UPS with 0.9 to unity output pf, 3 phase input & 3 phase output complete with all protections as per specification no. AP-UPS

2

-

-

... More
Supplying, erecting, testing and commissioning of 20kVA capacity online pure sine wave, with backup time of ....... hrs. PWM & IGBT based UPS with 0.9 to unity output pf, 3 phase input and 3 phase output complete with all protections as per specification no. AP-UPS

3

-

-

... More
Supplying and erecting 12V/42Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete (30 nos. Natteries required for Single 10 KVA UPS. Therefore 3 nos. 10 KVA UPS x 30 Nos. Batteries = 90 No. Batteries)

80

-

-

... More
Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

390

-

-

... More
Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

364

-

-

... More
Supplying, erecting & marking TPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

69

-

-

... More
Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

14

-

-

... More
Supplying, erecting and marking four pole isolators only switch version of miniature circuit breakers of 40A in provided distribution board.

2

-

-

... More
Supplying, erecting and marking four pole isolators only switch version of miniature circuit breakers of 63A in provided distribution board.

3

-

-

... More
Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 4 ways/phase (12 poles), with door, 1.2mm thickness, surface/flush mounted, IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB

50

-

-

... More
Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 8 ways / phase (24 poles), with door, 1.2mm thickness surface/ flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB

4

-

-

... More
Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 4 ways /12 Poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB

4

-

-

... More
Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 2 ways (2 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB

9

-

-

... More
Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB

3

-

-

... More
Supplying & erecting CRCA sheet metal enclosures of 1.2mm thickness with 20A, 2 pin plug & earth socket and 20A, 3 pin plug top with 20A/30A single pole MCB having rated short - circuit breaking capacity (Icn) 10kA complete erected on angle iron/ GI frame.

11

-

-

... More
Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame.

19

-

-

... More
Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/4 pole MCCB as incomer & outgoing SP MCB (24 poles) or TP MCB of 8 ways (24 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1

2

-

-

... More
Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/4 pole MCCB as incomer & outgoing SP MCB (36 poles) or TP MCB of 12 ways (36 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1

3

-

-

... More
Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB [Note 1)For use of 4 pole MCCBs in place of 3 pole MCCBs add 20% in rate of 3 pole MCCB. Rs. 5309.00 + Rs. 1061.80 = Rs. 6,370.80]

5

-

-

... More
Supplying, erecting & commissioning 4 pole RCCB 63A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB

6

-

-

... More
Supplying, fixing and commissioning 2 pole, RCBO 6/10/16/20/25A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO

11

-

-

... More
Supplying, fixing and commissioning 4 pole RCBO 6/10/16/20/25A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indications per specification no SW-RCCB/RCBO

53

-

-

... More
Supplying, fixing and commissioning 4 pole RCBO 32/40A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO

2

-

-

... More
APFC Panel - 200 KVAR :-Supplying and erecting 200 kVAr, 440 V 3 phase, 50 Hz., Contactor Logic & Intelligent Relay micro APFC passive filter panel, consisting of suitable steps of APP/MPP type capacitor units with Detuned (harmonic filter) reactors of suitable rating , APFC panel shall be compliance to IEC 61439 and power quality IEC 61921 standard as per specification no CP-ED/APFC

1

-

-

... More
Main LT Panel:- Supplying and erecting ON LOAD four pole automatic transfer switch, 415V, 400A, 50 Hz with enclosure, flexibility of neutral connection, line and load reversibility, changeover with phase barriers, source separator, terminal covers along with staggered termination for cable connection and ATS controller with provision of time delay protection of OV, UV, phase sequence changing, single phasing and event logging, connected with provided leads complete complying to IS/IEC 60947-3 Part-1/6 .

1

-

-

... More
Supplying, erecting & marking DPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

7

-

-

... More
Supplying, erecting & marking DPMCB 40A to 63A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

1

-

-

... More
Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

16

-

-

... More
Providing & erecting 3 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB

4

-

-

... More
Providing & erecting 3 Pole MCCB, 415V, 200A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB

1

-

-

... More
Providing & erecting 3 Pole MCCB 415V, 400A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure /panel as per specification no. SW-SWR/MCCB [Note 1)For use of 4 pole MCCBs in place of 3 pole MCCBs add 20% in rate of 3 pole MCCB. = Rs. 18563 /- + 3,712.6 (20%) = 22275.60/-]

1

-

-

... More
Supplying & erecting porcelain/epoxy bus bar support complete erected in provided M.S. box for 400A

12

-

-

... More
Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete.

85

-

-

... More
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.

10

-

-

... More
Supplying and erecting of any size electrolyte aluminium patti or bar in bus bar chamber / in panel or any other purpose, 500 V with require capacity 99.9% aluminium purity with E91E Grade as per IS 5082 & Current Density 0.8 A per sq. mm. with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as per specification no. BCP-BB

13

-

-

... More
Supplying and erecting panel mounting type digital ammeter having three and half digit LED display, external CT operated, calibrated for suitable to operate on 500V, 0 to 1000A having accuracy class of 0.5, AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.

1

-

-

... More
Supplying and erecting panel mounting type digital voltmeter having three and half digit LED display, calibrated for 0 to 750V AC suitable to operate on 500V having accuracy class of 0.5 ,AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.

1

-

-

... More
Supplying and erecting selector switch suitable for voltmeter/ammeter for 3 phase AC supply 500V, 50Hz, on provided box / panel and duly connecting with necessary PVC wire leads and lugs.

2

-

-

... More
Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates.

3

-

-

... More
Supplying & erecting LED type indicating pilot lamp with LED colours red / yellow / green, 230 / 250V on provided box / panel with necessary material, wiring & connections etc.

2

-

-

... More
Supplying & erecting LED type indicating pilot lamp with LED colour blue, 230 / 250 V on provided box / panel with necessary material, wiring & connections etc.

1

-

-

... More
HVAC Panel - OPD:- Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

13

-

-

... More
Providing & erecting 4 Pole MCCB, 415V, 200A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB [Note 1)For use of 4 pole MCCBs in place of 3 pole MCCBs add 20% in rate of 3 pole MCCB. = Rs. 10604/- + 2120.8 (20%) = 12,724.80/-]

1

-

-

... More
Supplying & erecting porcelain/epoxy bus bar support complete erected in provided M.S. box for 200/300A

12

-

-

... More
Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete.

40

-

-

... More
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.

10

-

-

... More
Supplying and erecting of any size electrolyte aluminium patti or bar in bus bar chamber / in panel or any other purpose, 500 V with require capacity 99.9% aluminium purity with E91E Grade as per IS 5082 & Current Density 0.8 A per sq. mm. with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as per specification no. BCP-BB

5

-

-

... More
Supplying and erecting panel mounting type digital ammeter having three and half digit LED display, external CT operated, calibrated for suitable to operate on 500V, 0 to 1000A having accuracy class of 0.5, AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.

1

-

-

... More
Supplying and erecting panel mounting type digital voltmeter having three and half digit LED display, calibrated for 0 to 750V AC suitable to operate on 500V having accuracy class of 0.5 ,AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.

1

-

-

... More
Supplying and erecting selector switch suitable for voltmeter/ammeter for 3 phase AC supply 500V, 50Hz, on provided box / panel and duly connecting with necessary PVC wire leads and lugs.

2

-

-

... More
Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates.

3

-

-

... More
Supplying & erecting LED type indicating pilot lamp with LED colours red / yellow / green, 230 / 250V on provided box / panel with necessary material, wiring & connections etc.

2

-

-

... More
Supplying & erecting LED type indicating pilot lamp with LED colour blue, 230 / 250 V on provided box / panel with necessary material, wiring & connections etc.

1

-

-

... More
CHANGEOVER PANEL FOR FIRE PUMP IN FIRE PUMP ROOM:- Supplying & erecting four pole ON LOAD change over switch, 415V, 200A, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, operational current category AC23A complying to IS/IEC 60947-3 Part-1/3.

1

-

-

... More
Providing & erecting 3 Pole MCCB, 415V, 200A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB

2

-

-

... More
Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete.

34

-

-

... More
Supplying and erecting panel mounting type digital ammeter having three and half digit LED display, external CT operated, calibrated for suitable to operate on 500V, 0 to 1000A having accuracy class of 0.5, AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.

1

-

-

... More
Supplying and erecting panel mounting type digital voltmeter having three and half digit LED display, calibrated for 0 to 750V AC suitable to operate on 500V having accuracy class of 0.5 ,AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.

1

-

-

... More
Supplying and erecting selector switch suitable for voltmeter/ammeter for 3 phase AC supply 500V, 50Hz, on provided box / panel and duly connecting with necessary PVC wire leads and lugs.

2

-

-

... More
Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates.

3

-

-

... More
Supplying & erecting LED type indicating pilot lamp with LED colours red / yellow / green, 230 / 250V on provided box / panel with necessary material, wiring & connections etc.

2

-

-

... More
Supplying & erecting LED type indicating pilot lamp with LED colour blue, 230 / 250 V on provided box / panel with necessary material, wiring & connections etc.

1

-

-

... More
LT Panel - Ward:- Supplying and erecting ON LOAD four pole automatic transfer switch, 415V, 400A, 50 Hz with enclosure, flexibility of neutral connection, line and load reversibility, changeover with phase barriers, source separator, terminal covers along with staggered termination for cable connection and ATS controller with provision of time delay protection of OV, UV, phase sequence changing, single phasing and event logging, connected with provided leads complete complying to IS/IEC 60947-3 Part-1/6 .

1

-

-

... More
Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

6

-

-

... More
Providing & erecting 3 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB

5

-

-

... More
Providing & erecting 3 Pole MCCB, 415V, 200A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB

1

-

-

... More
Providing & erecting 4 Pole MCCB 415V, 400A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure /panel as per specification no. SW-SWR/MCCB [Note 1)For use of 4 pole MCCBs in place of 3 pole MCCBs add 20% in rate of 3 pole MCCB. = Rs. 18563 /- + 3,712.6 (20%) = 22275.60/-]

1

-

-

... More
Supplying & erecting porcelain/epoxy bus bar support complete erected in provided M.S. box for 400A

12

-

-

... More
Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete.

85

-

-

... More
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.

10

-

-

... More
Supplying and erecting of any size electrolyte aluminium patti or bar in bus bar chamber / in panel or any other purpose, 500 V with require capacity 99.9% aluminium purity with E91E Grade as per IS 5082 & Current Density 0.8 A per sq. mm. with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as per specification no. BCP-BB

13

-

-

... More
Supplying and erecting panel mounting type digital ammeter having three and half digit LED display, external CT operated, calibrated for suitable to operate on 500V, 0 to 1000A having accuracy class of 0.5, AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.

1

-

-

... More
Supplying and erecting panel mounting type digital voltmeter having three and half digit LED display, calibrated for 0 to 750V AC suitable to operate on 500V having accuracy class of 0.5 ,AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.

1

-

-

... More
Supplying and erecting selector switch suitable for voltmeter/ammeter for 3 phase AC supply 500V, 50Hz, on provided box / panel and duly connecting with necessary PVC wire leads and lugs.

2

-

-

... More
Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates.

3

-

-

... More
Supplying & erecting LED type indicating pilot lamp with LED colours red / yellow / green, 230 / 250V on provided box / panel with necessary material, wiring & connections etc.

2

-

-

... More
Supplying & erecting LED type indicating pilot lamp with LED colour blue, 230 / 250 V on provided box / panel with necessary material, wiring & connections etc.

1

-

-

... More
HVAC Panel - Ward12/27/2024-Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

8

-

-

... More
Providing & erecting 4 Pole MCCB, 415V, 200A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB [Note 1)For use of 4 pole MCCBs in place of 3 pole MCCBs add 20% in rate of 3 pole MCCB. = Rs. 10604/- + 2120.8 (20%) = 12,724.80/-]

1

-

-

... More
Supplying & erecting porcelain/epoxy bus bar support complete erected in provided M.S. box for 200/300A

12

-

-

... More
Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete.

40

-

-

... More
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.

10

-

-

... More
Supplying and erecting of any size electrolyte aluminium patti or bar in bus bar chamber / in panel or any other purpose, 500 V with require capacity 99.9% aluminium purity with E91E Grade as per IS 5082 & Current Density 0.8 A per sq. mm. with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as per specification no. BCP-BB

5

-

-

... More
Supplying and erecting panel mounting type digital ammeter having three and half digit LED display, external CT operated, calibrated for suitable to operate on 500V, 0 to 1000A having accuracy class of 0.5, AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.

1

-

-

... More
Supplying and erecting panel mounting type digital voltmeter having three and half digit LED display, calibrated for 0 to 750V AC suitable to operate on 500V having accuracy class of 0.5 ,AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.

1

-

-

... More
Supplying and erecting selector switch suitable for voltmeter/ammeter for 3 phase AC supply 500V, 50Hz, on provided box / panel and duly connecting with necessary PVC wire leads and lugs.

2

-

-

... More
Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates.

3

-

-

... More
Supplying & erecting LED type indicating pilot lamp with LED colours red / yellow / green, 230 / 250V on provided box / panel with necessary material, wiring & connections etc.

2

-

-

... More
Supplying & erecting LED type indicating pilot lamp with LED colour blue, 230 / 250 V on provided box / panel with necessary material, wiring & connections etc.

1

-

-

... More
LT Cable:-Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

200

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

100

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 50 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

60

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 95 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

350

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 120 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

100

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 185 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

1100

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 300 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

30

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

245

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 4 sq mm copper conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU

240

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU

770

-

-

... More
Supplying & erecting G.I. pipe ‘A’ class 50 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE

12

-

-

... More
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.

370

-

-

... More
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 120 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.

310

-

-

... More
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 200 mm outside dia, double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.

1000

-

-

... More
CABLE TRAY:- Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 300 mm width & 100 mm height comprising all required standard accessories.

575

-

-

... More
EARTHING:- Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP

18

-

-

... More
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.

828

-

-

... More
TELEPHONE SYSTEM:- Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.

175

-

-

... More
Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.

555

-

-

... More
Supplying and erecting modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connections complete.

35

-

-

... More
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.

35

-

-

... More
Supplying & erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW

1285

-

-

... More
Supplying & erecting 10 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW

35

-

-

... More
Supplying & erecting 20 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW

70

-

-

... More
Supplying & erecting 0.5 mm dia, copper jumper wire as per specification No. WG-TW

35

-

-

... More
Supplying, erecting & commissioning MDF Box 50x50 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW

1

-

-

... More
Supplying, erecting & commissioning 10 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TW

1

-

-

... More
Supplying, erecting & commissioning 20 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TW

2

-

-

... More
Supplying, erecting & commissioning 10 pair module for connection & disconnection of telephone cable as per specification no. WG-TW

10

-

-

... More
Supplying & erecting over voltage protection magazine suitable for 10 pair as per specification no. WG-TW

10

-

-

... More
Supplying and installing, testing & commissioning of digital (hybrid) type EPABX of 6 x 32 extensions suitable upto 96 extensions complete.

1

-

-

... More
COMPUTER SYSTEM:- Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.

475

-

-

... More
Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.

1480

-

-

... More
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.

95

-

-

... More
Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC

3625

-

-

... More
Supplying and erecting LSZH armoured multimode optical fibre cable with 24 fibres, core dia 50/125 µm (OM3), suitable up to 10 GBPS ethernet distance at 850 nm of wavelength, on wall/ceiling or laid in provided pipe/trench as per specification No. WG-COC/OFC

315

-

-

... More
Supplying and fixing 1 m length, UTP patch cord of enhanced Cat 6 type with 4-connector channel, performance test report as per ANSI/TIA-568.2-D in position as per specification No. WG-COC/PC

95

-

-

... More
Supplying, fixing, and configuring 24 ports with 4 (SFP+) port, ethernet managed switch with web view/CLI, 6KV surge protection on ethernet port and console port for management in provided rack as per specification no. WG-NWC/GBS

7

-

-

... More
Supplying, installing and testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC.

95

-

-

... More
Supplying and fixing tool-less IO (Ethernet) flush/surface type in provided modular box as per specification no. WG-NAS/IO

95

-

-

... More
Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x600x367 mm) as per specification No. WG-NAS/RAK

7

-

-

... More
Supplying and fixing 32 U floor mount server Rack (Dimension-DxWxH - 800X1000x1620 mm) as per specification No. WG-NAS/RAK

1

-

-

... More
AIR CONDITIONING UNIT-VRV Outdoor Condenser Unit:- Supplying, erecting, testing and commissioning of 12HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete. Each 453999

12

-

-

... More
Supplying, erecting, testing and commissioning of 16HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete. Each 453999

12

-

-

... More
Supplying, erecting, testing and commissioning of 18HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/ digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete.

9

-

-

... More
Supplying, erecting, testing and commissioning of 20HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56°C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete.

15

-

-

... More
VRV Indoor Unit:-Supply, installation, testing and commissioning of VRF/VRV based Hi-wall type room/indoor unit (IDU) of nominal cooling capacity 1.0TR (358 cfm) to 1.25TR (417 cfm) having EER as per BEE standards and specifications with multiple speed evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, in built drain pump, expansion device, cordless remote control with necessary controls and electrical terminal to receive power supply, etc. IDU shall have anti-corrosive coating suitable for coastal area. Unit shall be of decorative slim dimension suitable indoor wall mounting. The indoor unit shall also have an electronic control console. The unit shall be suitable for wall mounting and provided with suitable mounting brackets with any additional refrigerant and oil charge as per requirement during installation complete.

4

-

-

... More
Supply, installation, testing and commissioning of VRF/VRV based Hi-wall type indoor unit (IDU) of nominal cooling capacity 1.3TR (421 cfm) to 1.7TR (586 cfm) having EER as per BEE standards and specifications with multiple speed evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, expansion device, cordless remote control with necessary controls, with 3-core copper flexible cord of required length and electrical terminal to receive power supply, etc. IDU shall have anticorrosive coating suitable for coastal area. Unit shall be suitable for indoor wall mounting, having an electronic control console, provided with suitable mounting brackets with any additional refrigerant and oil charge as per the requirement during installation, connected to the system complete.

44

-

-

... More
Supply, installation, testing and commissioning of VRF/VRV based Hi-wall type indoor unit (IDU) of nominal cooling capacity 1.8TR (594 cfm) to 2.2TR (655 cfm) having EER as per BEE standards and specifications with multiple speed evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, expansion device, cordless remote control with necessary controls, with 3-core copper flexible cord of required length and electrical terminal to receive power supply, etc. IDU shall have anticorrosive coating suitable for coastal area. Unit shall be suitable for indoor wall mounting, having an electronic control console, provided with suitable mounting brackets with any additional refrigerant and oil charge as per the requirement during installation, connected to the system complete.

8

-

-

... More
Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact/standard size) of nominal cooling capacity 2.0TR (618 cfm) to 2.3TR (671 cfm) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation

17

-

-

... More
Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 2.6TR (918 cfm) to 2.8TR ( 1100 cfm ) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation

14

-

-

... More
Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 3.0TR (1100 cfm) to 3.2TR (1165 cfm) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation.

26

-

-

... More
Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 3.3TR (1165 cfm) to 4.0TR (1218 cfm ) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation

126

-

-

... More
Accessories:- Supplying and installation of high pressure grade required size copper connection Y or T- Joints/refnet complete erected on wall/ceiling with supports/raceways, Nitrile rubber insulation, painting etc. with brazing and testing for leakages confirming the normal operation of the VRV/VRF air conditioning system.

239

-

-

... More
Supplying and erecting circular flexible/rigid PVC pipe duct of size 40mm dia, 4mm thickness with required couplers, reducers, T-joints, Y-joints elbows and necessary supports etc. with sealing with provided control/air flow regulating valves/dampers, filters at position complete. Insulation for AC drainage system.

330

-

-

... More
Supplying and erecting circular flexible/rigid PVC pipe duct of size 50mm dia, 4mm thickness with required couplers, reducers, T-joints, Y-joints elbows and necessary supports etc. with sealing with provided control/air flow regulating valves/dampers, filters at position complete. Insulation for AC drainage system.

275

-

-

... More
Supplying and erecting circular flexible/rigid PVC pipe duct of size 80mm dia, 4mm thickness with required couplers, reducers, T-joints, Y-joints elbows and necessary supports etc. with sealing with provided control/air flow regulating valves/dampers, filters at position complete. Insulation for AC drainage system.

155

-

-

... More
Supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 41.3mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete.

770

-

-

... More
Refrigerant Copper Piping:- Supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 34.9mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete.

475

-

-

... More
supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 28.6mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete.

440

-

-

... More
supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 22.2mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiation with OEM standards of VRV/VRF air conditioning system complete

355

-

-

... More
supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 19.1mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete.

1230

-

-

... More
supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 15.9 mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete

510

-

-

... More
supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 12.7mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete.

840

-

-

... More
supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 9.5 mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete.

145

-

-

... More
supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 6.4mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete.

425

-

-

... More
Centralised Remote Controller system (CRC):- Supplying, erecting, testing and commissioning centralised programmable remote control panel (HMI) touch manager controls minimum 16 system of 64 ODU's can be controlled and up to 992 IDU's can be individually mounted and controlled indoor units having colour min 200mm size LCD touch panel, yearly schedule, power proportional distribution function, temperature limitation, history function complete erected on wall integrated with provided fire alarm system.

14

-

-

... More
Supplying, installing, testing and commissioning FR, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU

6069.6

-

-

... More
Miscellaneous:-Supplying and erecting circular flexible/rigid PVC pipe duct of size 80mm dia, 4mm thickness with required couplers, reducers, T-joints, Y-joints elbows and necessary supports etc. with sealing with provided control/air flow regulating valves/dampers, filters at position complete.

450

-

-

... More
Air Curtain:- Supply, installation, testing and commissioning air curtain of 6 feet width having air throw velocity of 21 m/sec, low noise level up to 38 to 46dBA suitable for door height upto 9 feet, working on 1 phase, 230V, 50Hz, A.C. supply.

15

-

-

... More
Ventilation & Exhaust Equipment:- Supplying, erecting, testing & commissioning fresh air intake system, ductable circular inline fresh air fan inlet unit having 300 cfm capacity with maintaining the static pressure minimum 20mm suitable to operate on 1 phase, 230V, 50Hz, A.C. supply complete.

15

-

-

... More
Supplying and erecting exhaust fan medium duty 230 V A.C. 50 cycles 225 mm. 1400 RPM with condenser complete erected in position with necessary materials. Fan motor with moisture proof treatment and ‘E’ class insulation.

181

-

-

... More
Ducting GSS Sheet:- Supplying and erecting GI sheet 0.6 mm (24 SWG) having zinc coating of 275 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint.

120

-

-

... More
Supplying and erecting GI sheet 0.8 mm (22 SWG) having zinc coating of 275 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting

150

-

-

... More
Indoor Insulation:- Providing adhesive thermal insulation for supply return air duct with 19mm nitrile rubber insulation having R-value as per the prevailing provisions in ECBC- 2017.

420

-

-

... More
Supply, fabrication, installation and testing of flexible canvas connections constructed between ductable unit/dampers/ducting of suitable size with fire resist flexible double canvas sleeve complete.

16

-

-

... More
Volume Control Damper:- Supply, installation, testing and commissioning of manually operated, opposed blade, duct mounted, flanged volume control dampers of required sizes in GI construction with operating mechanism, mounting arrangement, rubber refrigerant kits etc. complete.

15

-

-

... More
Grilles & Diffuser:- Supplying & erecting tile type modular diffuser made from aluminium sheet with powder coated matching to the ceiling shade for provided supply and return air complete.

51

-

-

... More
Supplying and erecting aluminium powder coated linear grill of suitable size for width length without collar dampers having matching colour with the existing false ceiling and suitable for deflection of 15/30/45°.

393

-

-

... More
PUMP HOUSE:-Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.

15

-

-

... More
Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

2

-

-

... More
Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

1

-

-

... More
Supplying, erecting & marking TPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

3

-

-

... More
Supplying, erecting and marking four pole isolators only switch version of miniature circuit breakers of 40A in provided distribution board.

1

-

-

... More
Supplying, fixing and commissioning MCB type change over switch 4 pole, 25A with 3 positions (I-O-II) with centre off position as per specification no. SW-SWR / MCBCOS

1

-

-

... More
Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 4 ways /12 Poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB

1

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

30

-

-

... More
Supplying and erecting minimum Three & above star rated submersible pump set of 2.25 KW/3HP with 415 V, 50 c/s AC supply suitable for 100 mm dia. borewell suitable for 50 to 180 LPM discharge at 98 to 39 m head & discharge & delivery pipe of Size-50 mm diameter with a necessary H type clamps as per specification No. WP-SMP

1

-

-

... More
Supplying and erecting minimum Three & above star rated submersible pump set suitable for erection on open well of 2.25 KW/3 HP with 415 V 50 c/s. A.C. supply, having delivery head from 27 to 9 m and discharge from 300 to 660 litres. per minute & pipe of Suction 65mm /Delivery 50 mm diameter erected with necessary H type clamps as per specification No. WP-OSP

2

-

-

... More
Supplying & erecting flat flexible 3 core 4 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete.

120

-

-

... More
Supplying & erecting automatic control panel for 3 Phase , 415 volt, A.C, Submersible/centrifugal pump set up to 7.5 HP consisting of DOL starter having relay range 9-14 AMP,S.P.P., Combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc .

3

-

-

... More
Supplying and erecting ISI mark GI pipe 50 mm dia.‘B’ class at position with accessories complete as per specification no. CW-PLB/GP.

12

-

-

... More
Supplying and erecting high density polythene pipe ISI mark 50 mm. dia. suitable for pressure of 6 kg. / cm2 connected to jet/submersible pump with required material complete.

90

-

-

... More
Supplying and erecting non return valve 50 mm dia in position made of gun metal complete.

3

-

-

... More
EARTHING:- Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP

2

-

-

... More
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.

24

-

-

... More
PUMP PANEL BOX NEAR BOREWELL:- Supplying, erecting & marking TPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

1

-

-

... More
Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame.

1

-

-

... More
Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete.

11.3

-

-

... More
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.

35

-

-

... More
STREET LIGHTING:-Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV

56

-

-

... More
Supplying and erecting integrated LED street light fitting 60W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 6600 Lumens, min. efficacy of 110 lumen/W, CRI70, CCT upto 6500K, THD10%, p.f. 0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2.

7

-

-

... More
Supplying and erecting integrated LED Post Top 45W IP65 & IK10 class having die cast aluminium housing with UV protected polycarbonate diffuser, having system lumens output of Min.4500 Lumens, min. efficacy of 100 lumen/W, CRI80, CCT upto 6500K, THD10%, p.f. 0.90, operating range of 140-240V, inbuilt surge protection of 2 kV, Life class of 30,000 Hrs. at L50B50 , including driver complete with 2 Year warranty as per specification No FG-ODF/FLS2.

2

-

-

... More
Supplying & erecting single phase, 240V, street light control panel up to the max load of 6kW, SPN MCB 40A, powder coated CRCA 14 SWG sheet, outdoor type, having IP54,IK10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protection on provided iron frame/ CC foundation.

1

-

-

... More
Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

7

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

265

-

-

... More
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.

225

-

-

... More
Providing & erecting 8 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 135 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL

7

-

-

... More
Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT

7

-

-

... More
Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP

8

-

-

... More
Making cement concrete foundation in 1:2:4 cement concrete with foundation bolts and nuts complete. (street light feeder pillar foundation = ( 1 M X 0.2 M X 0.3 M) X 2 = 0.12 Cu. Mtr.)

0.12

-

-

... More
Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole).

7

-

-

... More
630 KVA TRANSFORMER:- Supplying, erecting, testing & commissioning 11kV, 630A, 21kA/3sec, 4 way outdoor, extensible motorised SCADA compatible RMU, internal arc tested consisting of 2 nos. feeder with 2 LBS and 2 nos. feeder with 2 VCB compliant to IEC 62271 -100, 200 and 102, as per specification no. SW-HTS/RMU SCADA

1

-

-

... More
Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 11 kV(E), 3 x 300 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT 2) 2) For round wire armouring increase rate For 11 kV (E) by 28% (Rs. 2753 + 28% Rs. 770.84 = Rs. 3523.84)

500

-

-

... More
Providing and erecting Heat shrinkable indoor termination kit for 11 kV ( E ) XLPE HT cable 3x240 to 300 sq. mm. with necessary material as per specification no. CB-JT/HT

6

-

-

... More
Providing and erecting Heat shrinkable out door termination kit for 11 kV ( E ) XLPE HT cable 3x240 to 300 sq. mm. with necessary material as per specification no. CB-JT/HT

2

-

-

... More
Supplying & erecting G.I. pipe ‘A’ class 75 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE

6

-

-

... More
Supplying & laying (including excavation) reinforced cement concrete pipe of IS 458:2003 NP-2 class of 250 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.

440

-

-

... More
Supplying, installation, testing and commissioning extendable/non-extendable outdoor type 11 kV 630A, load break isolator switch, compliant to IEC 62271 -100, 200 and 102,on provided MS channels/trench/foundation as per specification no SW-HTS / LBS

1

-

-

... More
Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete.

8

-

-

... More
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP

8

-

-

... More
Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results as per specification no. EA-EP

2

-

-

... More
Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EA-EP.

30.44

-

-

... More
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.

96

-

-

... More
Supplying, installing, testing & commissioning 3 phase, 11/0.433 kV, 50 Hz., 630 kVA, Mineral oil immersed and naturally cooled outdoor type, Copper wound Non-sealed transformer delta/star connected additional neutral brought out on load side, temperature rise should not exceed 45℃ by thermometer in oil and 50℃ by the resistance method in winding at full load rating, using type A winding insulation (kraft paper) with HV tapping (with off load tap changer) off load +5 to -10 in steps of 2.5%, having 7 number of tap positions , with standard accessories complete with test certificate with losses below 1860 Watts at 50% load, 5300 Watts at 100% load as per IS:1180 (part 1) : 2014 with necessary permissions of Electrical Inspector, as per specification no SS- TR-NSL.

1

-

-

... More
Supplying and erecting fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work erected in CC foundation and painted complete as per specification no SS-AS/FSG

26

-

-

... More
Supplying and erecting 50 x 50 x 6 mm angle iron as corner support 2m long fixed at the middle of the fencing frame and the other side inclined at 30 degree angle, in cement concrete foundation of 15 x 15 x 40 cm complete duly painted with one coat of red oxide and two coats aluminium paint complete.

4

-

-

... More
Supplying and erecting double leaf hinged door each 1500 mm in width x 1850 mm in height using B class, GI pipe with angle iron supports, chain link wire mesh (jali) complete supported on channel iron, erected in foundation, and painted complete as per specification no SS-AS/DLD

1

-

-

... More
Providing printed instruction chart for treating persons suffering from electric shock, printed in English & Marathi and duly laminated complete.

2

-

-

... More
Providing pair of duly tested rubber hand gloves as per IS :47705 suitable for working up to 22 kV supply complete.

1

-

-

... More
Supplying standard first aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use, scissors, anti-septic solution, etc. (All above contents shall be of standard makes)

1

-

-

... More
Supplying and spreading stone metal 25 mm size for 100 mm depth above the ground level complete.

58

-

-

... More
Transformer Plinth:-Making cement concrete foundation in 1:2:4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) (for pumps).

16

-

-

... More
LT FEEDER PILLAR:- Supplying, erecting & marking TPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

1

-

-

... More
Providing & erecting 3 Pole MCCB, 415V, 200A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB

1

-

-

... More
Providing & erecting 3 Pole MCCB 415V, 250A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB

2

-

-

... More
Providing & erecting 3 Pole MCCB 415V, 400A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure /panel as per specification no. SW-SWR/MCCB

3

-

-

... More
Providing & erecting 4 Pole MCCB, 415V, 800A, rated short-circuit breaking capacity 50 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB [1)For use of 4 pole MCCBs in place of 3 pole MCCBs add 20% in rate of 3 pole MCCB. = 37223 + 7444.6 = 44667.6/-]

1

-

-

... More
Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete.

83

-

-

... More
Supplying and erecting of any size electrolyte aluminium patti or bar in bus bar chamber / in panel or any other purpose, 500 V with require capacity 99.9% aluminium purity with E91E Grade as per IS 5082 & Current Density 0.8 A per sq. mm. with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as per specification no. BCP-BB

22

-

-

... More
Supplying and erecting panel mounting type digital ammeter having three and half digit LED display, external CT operated, calibrated for suitable to operate on 500V, 0 to 1000A having accuracy class of 0.5, AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.

1

-

-

... More
Supplying and erecting panel mounting type digital voltmeter having three and half digit LED display, calibrated for 0 to 750V AC suitable to operate on 500V having accuracy class of 0.5 ,AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.

1

-

-

... More
Supplying and erecting selector switch suitable for voltmeter/ammeter for 3 phase AC supply 500V, 50Hz, on provided box / panel and duly connecting with necessary PVC wire leads and lugs.

2

-

-

... More
Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates.

3

-

-

... More
Supplying & erecting LED type indicating pilot lamp with LED colours red / yellow / green, 230 / 250V on provided box / panel with necessary material, wiring & connections etc.

2

-

-

... More
Supplying & erecting LED type indicating pilot lamp with LED colour blue, 230 / 250 V on provided box / panel with necessary material, wiring & connections etc.

1

-

-

... More
Making cement concrete foundation in 1:2:4 cement concrete with foundation bolts and nuts complete. (0.45x0.45x0.45, 2 nos.)

4

-

-

... More
600 KVA DIESEL GENERATING SET:- Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP

4

-

-

... More
Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results as per specification no. EA-EP

2

-

-

... More
Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EA-EP.

30.44

-

-

... More
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.

48

-

-

... More
Supplying, erecting, testing and commissioning of diesel generating set with alternator of 625 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 81.90 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 690 Ltr etc. on provided M20 Grade CC Foundation and obtaining necessary approval from Electrical Inspector as per specification no. GEN-DG along with sound proof acoustic enclosure complying to CPCB - IV + noise limits with STD panel

1

-

-

... More
DG Foundation:- Making cement concrete foundation in 1:2:4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) (for pumps).

26

-

-

... More
DG Feeder Pillar:- Supplying, erecting & marking DPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB

1

-

-

... More
Providing & erecting 3 Pole MCCB, 415V, 200A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB

1

-

-

... More
Providing & erecting 3 Pole MCCB 415V, 400A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure /panel as per specification no. SW-SWR/MCCB [Note 1)For use of 4 pole MCCBs in place of 3 pole MCCBs add 20% in rate of 3 pole MCCB. = Rs. 18563 /- + 3,712.6 (20%) = 22275.60/-]

2

-

-

... More
Providing & erecting 4 Pole MCCB, 415V, 800A, rated short-circuit breaking capacity 50 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB [Note 1)For use of 4 pole MCCBs in place of 3 pole MCCBs add 20% in rate of 3 pole MCCB. = Rs. 37,223 /- + 7,444.60 (20%) = 44,667.60/-]

1

-

-

... More
Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete.

79

-

-

... More
Supplying and erecting of any size electrolyte aluminium patti or bar in bus bar chamber / in panel or any other purpose, 500 V with require capacity 99.9% aluminium purity with E91E Grade as per IS 5082 & Current Density 0.8 A per sq. mm. with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as per specification no. BCP-BB

22

-

-

... More
Supplying and erecting panel mounting type digital ammeter having three and half digit LED display, external CT operated, calibrated for suitable to operate on 500V, 0 to 1000A having accuracy class of 0.5, AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.

1

-

-

... More
Supplying and erecting panel mounting type digital voltmeter having three and half digit LED display, calibrated for 0 to 750V AC suitable to operate on 500V having accuracy class of 0.5 ,AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.

1

-

-

... More
Supplying and erecting selector switch suitable for voltmeter/ammeter for 3 phase AC supply 500V, 50Hz, on provided box / panel and duly connecting with necessary PVC wire leads and lugs.

2

-

-

... More
Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates.

3

-

-

... More
Supplying & erecting LED type indicating pilot lamp with LED colours red / yellow / green, 230 / 250V on provided box / panel with necessary material, wiring & connections etc.

2

-

-

... More
Supplying & erecting LED type indicating pilot lamp with LED colour blue, 230 / 250 V on provided box / panel with necessary material, wiring & connections etc.

1

-

-

... More
Making cement concrete foundation in 1:2:4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) (for pumps).

0.24

-

-

... More
CCTV SYSTEM:-Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC

505

-

-

... More
Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC

2020

-

-

... More
Supplying and erecting 3m HDMI cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete.

1

-

-

... More
Supplying and erecting 10m HDMI cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete.

1

-

-

... More
Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC

4850

-

-

... More
Supplying and erecting LSZH armoured multimode Optical Fibre Cable with 24 fibres, core dia 50/125 µm (OM4) suitable up to 10 GBPS ethernet distance at 850 nm of wavelength, on wall/ceiling or laid in provided pipe/trench as per specification No. WG-COC/OFC

135

-

-

... More
Supplying, fixing, and configuring 24 ports, POE switch in provided rack as per specification No. WG-NWC/ENS

6

-

-

... More
Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP

6

-

-

... More
Supplying and fixing POE adaptor to provide DC supply to ethernet devices as per specification No. WG-NAS/PEA

6

-

-

... More
Supplying & erecting of High definition 4/5 Megapixel IP IR Bullet Camera with following features Image Sensor : minimum 1/2.8" Progressive Scan CMOS, Video Resolution : minimum 2592 x 1520 Video Compression : H.264, H.265 or higher, at least Three individually configurable stream, Frame rate : minimum 25 fps at all resolutions, WDR : minimum 120 dB Wide Dynamic Range, ONVIF profile conformant, minimum IR distance : 50m, Lens Type : 2.8/4/6 mm Lens, fixed focal, Field of View : 2.8 mm, horizontal FOV 107°, vertical FOV 57°, diagonal FOV 129° 4 mm, horizontal FOV 86°, vertical FOV 47°, diagonal FOV 102° 6 mm, horizontal FOV 55°, vertical FOV 29°, diagonal FOV 65° Lux sensitivity - minimum 0.2 Lux at color, minimum 0.05 Lux at Black & White, 0.0 Lux (IR) Night Vision Distance minimum IR - 50m. Camera minimum Adjustment Angles - Pan : 350°, Tilt : 72°, Rotate : 350°. Power Supply : Support 12VDC & PoE, IP67, IK10 - Vandal Resistant. Built in micro SD/SDHC/SDXC card slot of minimum 128 GB, Built in microphone. minimum Input/Output - Audio in × 1, Audio Out × 1, Alarm in × 1, Alarm Out × 1. Image Settings : Rotate mode, saturation, brightness, contrast, sharpness, gain, white balance. Image Enhancements : Day/Night-Auto (ICR)/Color/Black & White, 3D Digital Noise Reduction, Automatic White Balance, Automatic Gain Control, Backlight Compensation, Highlight Compensation. Events : Privacy Masking, Motion detection, Scene change detection, Face capture, Video tampering, audio exception detection, Region entrance detection, Region exiting detection. Operating temperature ( -30 to 60° C ) . Security - User account and password protection, HTTPS, IP filter, IEEE 802.1X, digest authentication, user access log, TLS1.2, AES - 256, SSH/Telnet closed, FTP disabled. Protocol - DHCP, UDP, HTTP, HTTPS, NTP, DNS, RTP, RTSP, SMTP, SSL/TLS, TCP/IP, Secure Real-Time Transport Protocol (SRTP), Bonjour, SNMP and Secure shell (SSH) supported protocol. RoHS, WEEE, ISO-14001 and REACH compliant, UL/EN OR equivalent BIS/TECH/STQC or any indian standards as applicable, CE, FCC certified. duly erected in position on wall/ceiling/false ceiling/provided pole (mounting height not more than 5 meter) etc with all accessories etc complete as per specification no. CCTV-CAM

12

-

-

... More
Supplying & erecting of High definition 4/5 Megapixel IP IR Dome Camera with following features Image Sensor : minimum 1/2.8" Progressive Scan CMOS, Video Resolution : minimum 2592 x 1520 Video Compression : H.264, H.265 or higher, at least Three individually configurable stream, Frame rate : minimum 25 fps at all resolutions, WDR : minimum 120 dB Wide Dynamic Range, ONVIF profile conformant, minimum IR distance : 50m, Lens Type : 2.8/4/6 mm Lens, fixed focal, Field of View : 2.8 mm, horizontal FOV 107°, vertical FOV 57°, diagonal FOV 129° 4 mm, horizontal FOV 86°, vertical FOV 47°, diagonal FOV 102° 6 mm, horizontal FOV 55°, vertical FOV 29°, diagonal FOV 65°

112

-

-

... More
Supplying, installing, testing & commissioning of 64/80 Ch Network Video Recorder (NVR), suitable connect Min. 64 IP Cameras, up to 5 Megapixel Resolution, with HDMI 1/VGA 1 and HDMI 2/VGA 2 outputs provided, Atleast one HDMI output of 4K resolution, atleast one VGA output with output up to 1920 × 1080, Support H.265 or higher, H.264, MJPEG, Supports Redundant Dual Power, Incoming Bandwidth 320 Mbps with minimum 8 SATA Hard Disks, ANR Technology, 8 SATA interfaces for 8 HDDs and capacity of each HDD up to 8TB, minimum 02 USB port, Alarm I/O 16/4, RJ-45 10/100/ 1000 Mbps self-adaptive Ethernet interface, support multi brand network Cameras, ONVIF conformance, Multiple network monitoring: Web viewer . support protocol TCP/IP, DHCP, DNS, DDNS, NTP, SADP, SMTP, NFS, iSCSI, UPnP™, HTTPS. RoHS, UL, CE, FCC certified. duly erected in provided U Rack with wiring connections, tagging and programming etc. complete as per specificationss no. CCTV-NVR Events : Privacy Masking, Motion detection, Scene change detection, Face capture, Video tampering, audio exception detection, Region entrance detection, Region exiting detection. Operating temperature ( -30 to 60° C ) . Security - User account and password protection, HTTPS, IP filter, IEEE 802.1X, digest authentication, user access log, TLS1.2, AES - 256, SSH/Telnet closed, FTP disabled. Protocol - DHCP, UDP, HTTP, HTTPS, NTP, DNS, RTP, RTSP, SMTP, SSL/TLS, TCP/IP, Secure Real-Time Transport Protocol (SRTP), Bonjour, SNMP and Secure shell (SSH) supported protocol. RoHS, WEEE, ISO-14001 and REACH compliant, UL/EN OR equivalent BIS/TECH/STQC or any indian standards as applicable, CE, FCC certified. duly erected in position on wall/ceiling/false ceiling/provided pole (mounting height not more than 5 meter) etc with all accessories etc complete as per specification no. CCTV-CAM.

2

-

-

... More
Supplying & erecting 8 TB internal Surveillance HDD suitable for SATA Port of NVR, interface transfer rate 6 GB/S, maximum sustained transfer rate 210 MB/Sec to 213 MB/S. Drive bay supported 08+, Cameras supported up to 64, Cache (MB) 256, Load/Unload Cycle -3000000, Work Load Rating per Year 180TB, MTBF 1000000 Hrs. HTTPS. RoHS, UL, CE certified, duly erected in position in provided NVR as per specification no. CCTV-HDD

6

-

-

... More
Supplying & erecting 55" professional LED display with 1920 *1080 ( Full HD) Display, suitable for 32/64 channel NVR and following features Brightness: minimum 500 Cd/m2 Contrast Ratio: minimum 1000:1 Viewing angle: 178/178 deg. Response time: maximum 8 ms Inputs: HDMI, VGA, BNC,USB, Audio In, Built-in speakers maximum 10 W, Suitable to operate on 100-240 V 50 Hz AC supply and 24/7 Duty Cycle duly erected on wall or table top with standard accessories like wall mount stand and wiring connections etc. complete as per specifications no. CCTV-MON

2

-

-

... More
PASSENGER LIFTs:- SITC of Electric Traction Passenger Lift with Rated capacity :- 10 Passenger/680Kg   Floors :- G+4 floor (5 Stops/5 Landings) Travel :- 3 to 19.6 mtrs Location of Lift Machine:- MR/MRL ·       Rated speed :- 1.0mps VS ·       Car/Landing door clear opening of 800 mm wide x 2000 mm high ·       Clear Car size of 1300 mm wide x 1350 mm deep x 2250mm high ·       Lift shaft available having clear size of 1900 mm wide x 2100 mm deep, 1600 mm Pit depth, 4200   Doors type :- COPO/TOPO Doors with frame made from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory).mm Overhead.   Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as ·       COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor per the directions of engineer in charge. LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings.   Fireman controller having fireman switch at fire Landing. ·       CCTV surveillance system comprises of 2 nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days with min.18” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge. Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength.·       Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work.Minor civil work such as alteration work if any necessary for erection of landing door frames and it's accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT.· General: - Job includes entire procedure of obtaining all necessary erection permissions & "License to Work the Lift" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. · The above rate includes Fully Comprehensive AMC for one year from the date of commissioning.ADD ON : NOTE NO. A 2 For Lift travelling up to six floors or at a speed of 1.0 mps, add as below, : For Lift having 800mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade solid (non-cladded) landing door [Two panel], this includes all necessary accessories like LOP's with UP/DN buttons-arrows-indicators, extension of guide rails, shaft wiring with trunking, traveling cables, main hoisting ropes/belts, & OSG rope landing doors with all accessories etc. necessary for the normal safe functioning of lift installation complete. (Rs.1,37,031 (G+4)) + NOTE NO. B 1 For Full Collective control system, add as below. For Lift travelling above First floor & up to Sixth floor (Rs. 27,340)Therefore Lift Price will be = Lift Price Rs. 12,99,498.00+ Note No. A 2 (Rs. 1,37,031) + Note No. B1 (Rs. 27,340.00) Lift Price = 12,99,498.00 + 1,37,031.00 + 27340.00 = 14,63,869.00

6

-

-

... More
SITC of Triplex Lift control system for three nos. microprocessor/PLC based simplex lift controllers along with necessary software with programming and hardware e.g. logic board, necessary communication/control/data cabling laying in rigid PVC conduits/trunking etc. complete.

6

-

-

... More
FIRE FIGHTING SYSTEM INSTALLATION:- Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

50

-

-

... More
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 50 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL

80

-

-

... More
Supplying, installation, testing and commissioning of main fire pump (MFP / EP) suitable for water discharge of 2280 to 2850 LPM at 90 to 70 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 55kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal type, single stage, centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation on with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/EP

2

-

-

... More
Supplying, installation, testing and commissioning of jockey fire pump (JP) suitable for water discharge of 180 to 240 LPM at 110 to 90 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 11 kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal/vertical type, multi stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/JP

2

-

-

... More
Supplying, installation, testing and commissioning of main fire pump (MFP/DP) suitable for water discharge of 2280 to 2850 LPM at 90 to 60 m head driven by 76 HP or suitable HP capacity diesel engine at required working speed suitable for manual/automatic operation and consisting of following : (a) Horizontal type, single stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520. (b) Water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12/24 volts DC electric starting equipment with battery of required AH capacity with necessary charger suitable to work on 230v, 50Hz AC supply, diesel tank of minimum 150ltr capacity with first filling of diesel up to 100% level with necessary piping with valves up to engine , exhaust pipe extended up to 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications etc. as required. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with engine assembly and accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/DP

1

-

-

... More
Supplying, erecting, testing & commissioning of fire pump control panel (FCP) of cubical construction, floor mounted type, fabricated from minimum 2 mm thick CRCA sheet, compartmentalised with hinged lockable doors, with enclosure protection class IP54, duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnection with suitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessories, mountings and internal wiring with adequate size copper conductor cable, earth terminals, numbering etc. complete in all respect, suitable for satisfactory operation of main fire pump and jockey (pressurisation) pumps (1working+1standby) with necessary accessories, wiring & cabling along with allied accessories with following incoming and outgoings, suitable for automatic & manual operation on 415V, 3 phase, 50Hz ac supply as per specifications the capacity of electric motor driven pump are as follows a. Main fire pump(MFP) having capacity of 22kW 1no (1 working) b. Jockey pump(JP) capacity of suitable capacity 2 nos(1 working +1 standby, alternate run per start in auto mode) comprises of the following features & switchgears: 1. Main incomer FP SFU having rotary handle with HRC fuses of suitable rating. 2. Electrolytic grade copper strips for busbar of suitable sizes for main incomer and branches to motor SFU's, starters & outgoing terminals with necessary accessories like stainless steel nut bolts with spring washers for connections, mounted on required no of epoxy or porcelain support insulators of suitable ratings etc. 3. Individual pump TPN SFU having rotary handle with HRC fuses of suitable rating. 4. Digital voltmeter & ammeter & RYB indicating lamps & push buttons & SPP, O/L & phase reversal protection with emergency stop switch. 5. TPN SPD 100kA Type 1 +2 tested. 6. Required pressure transducer with pressure indication on panel with cabling required for monitoring & automatic operation of fire pumps. 7. System controller to control operation of main electric fire pump, jockey (pressurization) pumps in sequence with interlocking for operation of pumps as per specification with automatic/manual operation with selector switch & alternate run of standby Pumps consisting of relays, timers. sensors, annunciation window for fault indication, complete as per specification. 8.Suitable capacity electric motor starters for all individual pumps with necessary push buttons & indications. 9. Siren of required capacity to be activated when main pump starts & allied accessories as per requirements of local CFO or as directed by engineer in charge. 10. Danger board as per IS. 11. Spare HRC fuses minimum 2nos of each individual rating with required bakelite fuse holder for main & jockey fire pumps MFP=(1working), JP = (1working+1standby, alternate run per start in auto mode) complete panel, as per specification no. FF-MFP/ECP Add on For addition of capacity of main electric motor driven fire pump MFP (1 working) for hydrant system is more than 22kW, add as follows in the basic cost of Item no 13-5-1 towards increased capacity switchgears and motor starters for main & jockey pumps along with necessary accessories for main & jockey fire pumps MFP=(1working), JP = (1working + 1standby, alternate run per start in auto mode)

1

-

-

... More
For main electric motor driven fire hydrant system pump of 55kW capacity & relevant capacity jockey pump add Rs…For addition of fire sprinkler system to basic fire hydrant system control panel(FCP) which includes one main electric motor driven fire pump MFP (1working) having __kW capacity & relevant capacity jockey pumps, add as follows in the basic cost of Item no 13-5-1 towards increased capacity switchgears busbar and additional motor starters for main & jockey pumps along with necessary accessories with software & hardware for main & jockey fire pumps additional Sprinkler system MFP=(1working)@22kW, JP = (1working+1standby, alternate run per start in auto mode) @relevant capacity

1

-

-

... More
For main electric motor driven fire sprinkler system pump of 55kW capacity (1Working) & relevant capacity jockey pumps (1working+1standby, alternate run per start in auto mode, add Rs….

1

-

-

... More
For addition of standby main diesel engine driven fire pump (1 standby), add as follows in the basic cost of Item no 13-5-1 towards required 12/24 v battery charger and diesel engine starter along with necessary accessories, indicators etc. with necessary interlocking and updation of control logic with interlocking for operation of pumps MFP for main (1working+1standby mode) & jockey fire pumps (1working+1standby, alternate run per start in auto mode) , add Rs....... The control for diesel engine comprises of automatic/manual selector switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode indicating lamp for high/ low Lub. oil pressure, high water temp and engine on indication battery charger suitable for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC voltmeter, and 0-20 A DC ammeter with all standard relays and accessories required for automatic operation of diesel engine with interlocking for operation of main fire pumps.

1

-

-

... More
Supplying and erecting G.I. pipe ‘C’ class ERW 25 mm dia with necessary fittings complete as per specification no. FF-PP

1264

-

-

... More
Supplying and erecting ISI mark GI pipe 32 mm. dia ‘C” class at position with accessories complete. Specification no. CW-PLB/GP.

499

-

-

... More
Supplying and erecting ISI mark GI pipe 40 mm. dia ‘C” class at position with accessories complete. Specification no. CW-PLB/GP.

797

-

-

... More
Supplying and erecting G.I. pipe ‘C’ class ERW 50 mm dia with necessary fittings complete as per specification no. FF-PP

497

-

-

... More
Supplying and erecting G.I. pipe ‘C’ class ERW 65 mm dia with necessary fittings complete as per specification no. FF-PP

240

-

-

... More
Supplying and erecting G.I. pipe ‘C’ class ERW 75/80 mm dia with necessary fittings complete as per specification no. FF-PP

531

-

-

... More
Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm dia with necessary fittings complete as per specification no. FF-PP

182

-

-

... More
Supplying and erecting G.I. pipe ‘C’ class ERW 150 mm dia with necessary fittings complete as per specification no. FF-PP

901

-

-

... More
Providing coating of bitumen paint & 4mm thick wrapping for underground 150 mm ring main of fire fighting system.

250

-

-

... More
Supplying and erecting 100 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS

2

-

-

... More
Supplying and erecting 150 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS

3

-

-

... More
Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV

12

-

-

... More
Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV

30

-

-

... More
Supplying and erecting 100 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV

2

-

-

... More
Supplying and erecting 150 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV

4

-

-

... More
Supplying and erecting 20 mm dia gun metal gate valve complete with PN16 pressure rating, as per specification no. FF-VL/GV

23

-

-

... More
Supplying and erecting 25 mm dia gun metal gate valve complete with PN16 pressure rating, as per specification no. FF-VL/GV

15

-

-

... More
Supplying and erecting stainless steel single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV

24

-

-

... More
Supplying and installing wall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) along with necessary accessories complete as per specification no. FF-FFA/HV

15

-

-

... More
Supplying and erecting 63mm dia, reinforced rubber lined (R.R.L.) hose pipe, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL

48

-

-

... More
Supplying and erecting 19 mm dia high pressure rubber hose pipe complete as per specification no. FF-FFA/RHP

450

-

-

... More
Supplying and erecting stainless steel branch pipe 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specifications no. FF-FFA/NZ

24

-

-

... More
Supplying and erecting 19 mm dia gun metal chrome plated nozzle complete as per specification no. FF-FFA/NZ

15

-

-

... More
Supplying and erecting 150 mm dia fire brigade header suitable for supplying water in fire tank complete as per specification no. FF-FA/FBC

1

-

-

... More
Supplying and erecting fire brigade header ( Siamese connection )of 150 mm dia, for supplying water in fire tank complete as per specification no. FF-FA/FMC

1

-

-

... More
Supplying and erecting 300 mm dia 1.5m in height air vessel / tank fabricated from min 5mm thick M.S. sheet complete as per specification no. FF-FFA/ACT

2

-

-

... More
Supplying and erecting 20/25mm dia gun metal air release cock, with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV

6

-

-

... More
Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, erected with provided G.I. pipe, elbow etc. complete as per specification no. FF-FFA/PG

18

-

-

... More
Supplying and erecting 12/15 mm dia pressure switch with provided isolation valve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS

5

-

-

... More
Supplying and erecting brass orifice plate having 6 mm. thickness, 160 mm outer dia with required diameter of inner hole at every double outlet hydrant valve as per specification no. FF-FFA/OP

24

-

-

... More
Supplying and erecting M.S./CRCA cabinet for housing Fire Brigade / SIEMESE connections (size 1250 x 400 x 300 mm.) made from 16 SWG sheet and angle iron 25 mm. x 25 mm. x 4 mm. having front doors with viewing glass (8" x 6") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5)

24

-

-

... More
Supplying, installing, testing and commissioning FR, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU

8000

-

-

... More
Supplying, installing, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the 8 loop capacity and capable of supporting upto 250 devices and detectors per loop, with on-board LCD display with min 16 lines of text, operating at 230 V 50 HZ - AC with inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 min in alarm condition, suitable provision for network connectivity, interfacing with third party equipment via a MODBUS/ OPC/ L-ON interface etc. conforming to IS 15908:2021, IS 2189: 2008, EN 54 & VDS / FM/ UL 864 (10th edition) with 3 years replacement warranty FF-AFAS/CP

1

-

-

... More
Supplying, installing, testing and commissioning of repeater panel with suitable battery backup of a minimum of 24 hours in normal condition and 30 min in alarm condition, 80 backlit alphanumeric LCD display with inbuilt buzzer to indicate fault/fire alarm, manual control keys for silence/mute and to reset the FACP from the repeater station. Panel size shall not more than 175 x 275 x 65 mm conforming to EN 54 or UL approved with 3 years equipment replacement warranty FF-AFAS/RP

1

-

-

... More
Supplying, installing, testing and commissioning of addressable optical smoke detector, single/twin LED’s with 360 degree view, suitable for low voltage 15 to 32 V DC two wires supply, in-built locking mechanism to check the removal and pilferage of the detector, in built isolation mode, start up current 300µA and alarm condition current shall be maximum 6.5 mA, operating temperature 0°C to 50°C, humidity 0-95% RH, IP 41, conforming to IS 2189: 2008, 11360_1985_Reff2020 EN 54 or UL Approved with 3 years equipment replacement warranty FF-AFAS/SD .

460

-

-

... More
Supplying, installing, testing and commissioning of intelligent addressable thermal/heat detector with rate of rise cum fixed temperature thermistor complete with base as required, suitable for temperature variations from -20°C to 38°C for fixed-heat and rate-of-rise type detectors and 0°C to 66°C for high heat type detectors, in built isolation mode, suitable for offices/ceiling cable trenches/less ventilation area's etc. with 3 years equipment replacement warranty IS : 2175 - 1988 reaffirmed 2000, IS 15908:2021 standards FF-AFAS/SD.

98

-

-

... More
Supplying, installing, testing and commissioning of addressable manual call points ( break glass type/pull station type), made of addressable break glass plastic square in shape surface/flush mounted with "Break Glass" massage embedded on the glass, complete erected with mounting base and required accessories conforming to EN 54 or UL listed with 3 years equipment replacement warranty FF-AFAS/MCP.

25

-

-

... More
Supplying, installing, testing and commissioning of addressable fire control/relay module complete as required, with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 reed relays, EN 54 or UL Listed FF-AFAS/CRM

10

-

-

... More
Supplying, installing, testing and commissioning of addressable fire monitor module complete as required. EN 54 or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/MM

10

-

-

... More
Supplying, installing, testing and commissioning of addressable fire isolator module complete as required. EN 54 /FM or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/ISM

10

-

-

... More
Supplying, installing, testing and commissioning of addressable horn cum strobe sound/ hooter, output frequency 500 to 1000 Hz with dB as per Chart given in IS 15908:2021, with flashing at 1 Hz over the strobe’s entire operating voltage range EN 54, conforming to IS 2189: 2008, IS 15908:2021 standards with 3 years equipment replacement warranty FF-AFAS/SSH.

25

-

-

... More
Supplying, erecting, testing and commissioning of quartzoid bulb sprinkler, 15 mm (½") dia. NBCM Body chrome finished, 68º C fixed temperature rating with deflector disc of conventional construction complete as per specification no. FF-SPR.

1180

-

-

... More
Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete.

30

-

-

... More
Supply & Erecting of fire exit sinages with Battery backup 24hrs auto glow sinages

15

-

-

... More
Supplying & erecting ABC fire extinguisher of 6 kg. capacity conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete.

100

-

-

... More
Supplying & erecting fire bucket 9 ltr capacity 04 Nos with M.S Stand

4

-

-

... More
WATER COOLER:-Supplying, erecting, testing and commissioning self contained water cooler 230/250V 50Hz nominal cooling capacity of 80 litres per hour and storage capacity 120 litres with partially stainless steel body as per specification no. AP-WCR/WC

5

-

-

... More
Supplying and erecting ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps with output of purified water minimum 0.33 litre/min with activated carbon filter and softener operating on 230V, single phase A.C. supply with UV fail & filter change indication system .(for TDS more than 200)

4

-

-

... More
Supplying and erecting candle filter with filter pot for water cooler.

4

-

-

... More
Supplying and erecting connector pipe for candle filter of water cooler.

4

-

-

... More
100 KW ON GRID SOLAR POWER PACK:- Supplying, installing, testing and commissioning of 100 kWp ON-GRID Solar PV System / Plant consisting Solar PV Poly Crystalline Panel (335 Wp X 300 Nos.) and Solar ON-GRID Inverter of similar capacity (THD3%) with interconnecting wires / cables up to solar ON GRID inverter, proper base plate, canopy box to house Inverter and necessary accessories i.e. ACDB/ DCDB , MCB etc. wiring up to solar Inverter in casing and capping, display board, sign board, two distinct earthing, lightning arrester, liaisoning charges, remote monitoring system with maintaining card / chip for 5 years including net charges for RMS System, complete up to net meter Installation and export to the grid with 5 year ON-SITE warranty and fully comprehensive maintenance contract as per Specification no. ESD-RT-ONG.

1

-

-

... More
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.

10320

-

-

... More
Supplying and erecting AC three phase HT CT multifunction net meter DLMS compliance of accuracy class 0.5, 3x 63.5V, 50Hz, with backlit LCD display, optical port & RS 232 port( measures import kWh, kVAh, export kWh, kVAh, net kWh, kVAh, V, I, kW, 6 months history of energy, load survey, TOD, tamper detection & logging, power ON/OFF events, instantaneous parameters of rating 1/5A with display in absence of power) with wiring connections and mounting hardware on provided panels complete with calibration certificate from manufacturer.

1

-

-

... More
HEAT PUMP:-Supplying, installing, testing and commissioning of Commercial Heat pump, having dimension : 1020 x 846 x 1840 (mm) max., Input power: 10.3 kW, 400 V, 3 Ph, 50 Hz, Output power: 38 kW having hot water temperature range 35°C to 52°C and ambient temperature range for max. efficiency 7°C to 43°C, with top throw fan, tube type heat exchanger 5 nos. inbuilt temperature sensor and two pressure sensors, centrally controlled operation, operational noise level: 65 dBA with provision for controlling auxiliary heater with necessary accessories complete with 5 years ON-SITE warranty.

2

-

-

... More
Supplying, installation and testing and commissioning of storage type Mild Steel mixing water tank of capacity 3000 ltrs. tested to a pressure of 8 kg/cm2, insulated with 50 mm thick rock wool with wire mesh around and cladded with 26 SWG aluminium of dish end type with working pressure of 6 kg/cm2, fabricated with 6 mm thick MS plate and dished ends with 8 mm thick plates complete with man hole cover, inner side of the tank coated with FRP coating of 3 mm thickness withstand temperature of 90°C provided with collars of 2" BSP for provision to install 6 numbers of electrical heating coils if required with thermal sensors for automatic operation and integrated into the electrical circuits of the circulation pumps and the heat pump with safety valve drain, inlet and outlet nozzle, pressure gauge with all necessary accessories complete.

4

-

-

... More
Supplying & erecting Pressure Booster Pump, single phase, 50C/s, A.C. supply of 1.125 KW/1.5 H.P., With discharge of 480 to 31 LPM for 10 to 50 Mtr Head & 25 mm suction/ 25 mm delivery pipe, for Domestic Pressure boosting applications.

2

-

-

... More
Supplying and erecting 20/25 mm (ID/OD) Chlorinated polyvinyl chloride pipe (CPVC), thickness 2.6 mm conforming to IS 15778 (CTS Series) with necessary CPVC fittings and solvent cement for Solar Water Heater System as per specification No. ESD-HWP/CPVC

145

-

-

... More
Supplying and erecting 32/40 mm (ID/OD) Chlorinated polyvinyl chloride pipe (CPVC), thickness 3.8 mm conforming to IS 15778 (CTS Series) with necessary CPVC fittings and solvent cement for Solar Water Heater System as per specification No. ESD-HWP/CPVC

40

-

-

... More
NURSE CALL SYSTEM For OPD IP ZONE CONTROLLER 1) This device shall be used as the main node device to network the Nurse Call System devices in Multi bed ward areas. Each Zone Controller has 3 communication ports which support chains of up to 24 call initiation devices each, up to as many over door lights as the number of call initiation devices, for a total maximum support of 72 call devices. 2) The connection shall be made with Cat 6 UTP cable and RJ45 of B standard. Total cable length from the Zone Controller to the last call device shall not be longer than 300 meters for each communication line on each communication port. 3) Zone Controller shall have power injectors to be included with the device to be used for injecting 12V power to be used on each communication line where required. Each power injector has 2 RJ45 ports to be connected at suitable locations to prevent voltage drops on the lines. Each power injector requires 110-240 V power. 4) There shall not be any limits to the number of Zone Controllers that can be used in a Nurse Call System, they may be placed in the network as necessary to extend the system. 5) The unit shall have 1 uplink data port which is connected to the hospital network switch. Its connection shall be made with Cat 6 UTP cable and RJ45 of B standard. 6) The unit shall have 1 port for 110-240 V power. 3.2.7. The unit must be configurable from the IP System controller. Approved makes: ZKR, HAMPTON, AUSCOM,AUSTCO

1

-

-

... More
OVER DOOR LIGHT I/O 1) Over Door Lights shall use environmentally friendly LEDs 2) It shall consist of red, green, and blue colored LED lights. 3) In normal condition, no light shall be lit. If the patient makes a nurse call, a red light shall be lit. After the nurse call, when the nurse presses the green presence button on the Call Unit, the light of the Over Door Light will turn green. 4) In Code Blue, the blue light shall be lit. 5) The outer casing of the Over Door Light shall be made of nonflammable PC- ABS-FR materials. 6) Over Door Light I/O shall have 2 ports for RJ45 endings for cabling in a chain with call units on one of the communication lines of the Zone Controller or a Room Control unit. 7) Its connection shall be made with Cat 6 UTP cable and RJ45 of B standard. Approved makes: ZKR, HAMPTON, AUSCOM,AUSTCO

2

-

-

... More
1) The unit shall be mounted on headboards where there are patient headboards or on the walls where it can be implemented within the system. 2) The unit has 2 Input/Output ports for RJ45 endings to directly connect to a Room Control Unit or for cabling in a chain with Over Door Lights and other call units and eventually to one Zone Controller. 3) On the standard Bed Side Call Unit front side there shall be; 4) A “start call” button with a red nurse symbol. 5) An “end call” button with a green tick mark symbol. 6) Reassurance backlight in order to give visual information about the call status. 7) Continuous backlight for easy visibility of the unit at night. 8) Pressing on the End Call button ends the call and turns the assigned overdoor light to green. IP System Controller logs the event as “Presence”. 9) Pressing the End Call button for the second time ends the “Presence” and turns off the assigned Overdoor light. 10) Pressing the Start Call button when there is “Presence” shall start an “Emergency Call” 11) Pressing the End Call button when there is “Emergency” shall end the “Emergency” and returns to initial “Presence”. 12) The Bedside Call Unit shall be made from nonflammable PC-ABS-FR materials. 13) It can be used individually as a call button where basic patient handset is not needed. Otherwise, its connection with the basic patient handset shall be easily established by connecting via RJ45. 14) A nurse call shall be initiated via the patient handset or the Bedside Call Unit. These two buttons shall be accepted by the system as equivalent. In the event that these buttons are pressed: 15) If the unit is able to transmit the call to the zone controller, the LED on the unit shall flash with 1.0-second intervals. Call transmission information shall be audibly notified to the patient. 16) If there is an error in call transmission, a continuous red light showing the error status shall only stop when the call termination button is pressed or room control connection is made. Subsequent presses of the button shall trigger an audio alert each time. 17) Its connection shall be made with Cat 6 UTP cable and RJ45 of B standard. Approved makes: ZKR, HAMPTON, AUSCOM,AUSTCO

8

-

-

... More
PATIENT HANDSET – Basic:- 1) This handset shall be used in beds in multibed ward areas. 2) It shall be ergonomically suitable to be handheld. 3) It shall be connected to the Bedside Call Unit with an independent cable. 4) On its front side there shall be; 5) A “start call” button with a red nurse symbol. 6) Reassurance LED light in order to give visual information about the call status. 7) Continuous LED light for easy visibility at night. 8) Call initiation and error notification procedures is the same as Bedside Call Unit except audio alerts are always issued by the Bedside Call Unit. Its call initiation button and call backlight work in parallel with the ones on the Bedside Call Unit. 9) Patient handset shall be made from nonflammable PC-ABS-FR materials Approved makes: ZKR, HAMPTON, AUSCOM,AUSTCO

8

-

-

... More
PULL-CORD CALL UNIT (WC/BATHROOM)::- 1) The Pull-cord Call Unit has 2 Input/Output ports for RJ45 endings to directly connect to a Room Control Unit or for cabling in a chain with Over Door Lights and other call units 2) On its front side, there shall be: 3) A call pull-cord with customizable length with minimum 1.5 meters to serve as a call-cord. 4) A call termination button (indicated by a green tick mark symbol) 5) Reassurance backlight in order to give visual information about the call status. 6) Continuous backlight for easy visibility of the unit at night. 7) A priority WC Emergency Call shall start when the cord is pulled turn the assigned overdoor light to red 8) Pressing on the End Call button ends the call and turns the assigned overdoor light to green. IP System Controller logs the event as “Presence”. 9) Pressing the End Call button for the second time ends the “Presence” and turns off the assigned Overdoor light. 10) Pulling the pull-cord when there is “Presence” shall start an “Emergency Call” 11) Pressing the End Call button when there is “Emergency” shall end the “Emergency” and returns to initial “Presence”. 12) Its connection shall be made with CAT6 UTP cable and RJ45 of B standard. Approved makes: ZKR, HAMPTON, AUSCOM,AUSTCO

2

-

-

... More
IN-WARD NURSE PANEL With STAND:- 1) This unit shall be used inside multi-bed areas that are covered with a Zone Controller with Nurse Desks located within the ward area. 2) The unit shall have a minimum 10” touchscreen. 3) The Unit shall be used to monitor the status of every assigned call point’s call and alarm status. 4) The origin room and bed information of all active nurse calls, code blue calls shall be shown with an audiovisual alert along with the call type. 5) Onscreen call points shall have notifications of relevant icons, colors, and tones according to their call status. 6) Calls shall be shown real-time. 7) Timestamp and error logs for situations when the energy supply of the panel is cut or there is no network connection shall be recorded on the IP System Controller. 8) If a call on the nurse panel is not responded to within a determinable amount of time, the call should be able to automatically be forwarded to other nurse panels. Panels can also be set to function as mirror panels either manually or automatically based on time of day. 9) If a panel needs to be changed, the new panel only needs to be given the old panel’s IP information, and this shall be enough to configure the panel. The other settings can be automatically configured from the IP System Controller. 10) The Unit shall have an embedded personnel locator built-in provided without external modules or locators. 11) Embedded personnel locators shall work with Staff Badges and Wristbands Call Units to log the Nurse and Patient presences to closest In-ward nurse panel or room control unit without any external infrastructure support. 12) The Power supply of the Unit shall be PoE+. Approved makes: ZKR, HAMPTON, AUSCOM,AUSTCO

2

-

-

... More
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC

50

-

-

... More
Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC

150

-

-

... More
Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC

220

-

-

... More
For Ward IP ZONE CONTROLLER:- 1) This device shall be used as the main node device to network the Nurse Call System devices in Multi bed ward areas. Each Zone Controller has 3 communication ports which support chains of up to 24 call initiation devices each, up to as many over door lights as the number of call initiation devices, for a total maximum support of 72 call devices. 2) The connection shall be made with Cat 6 UTP cable and RJ45 of B standard. Total cable length from the Zone Controller to the last call device shall not be longer than 300 meters for each communication line on each communication port. 3) Zone Controller shall have power injectors to be included with the device to be used for injecting 12V power to be used on each communication line where required. Each power injector has 2 RJ45 ports to be connected at suitable locations to prevent voltage drops on the lines. Each power injector requires 110-240 V power. 4) There shall not be any limits to the number of Zone Controllers that can be used in a Nurse Call System, they may be placed in the network as necessary to extend the system. 5) The unit shall have 1 uplink data port which is connected to the hospital network switch. Its connection shall be made with Cat 6 UTP cable and RJ45 of B standard. 6) The unit shall have 1 port for 110-240 V power. 7) The unit must be configurable from the IP System controller. Approved makes: ZKR, HAMPTON, AUSCOM,AUSTCO

11

-

-

... More
OVER DOOR LIGHT:- 1) Over Door Lights shall use environmentally friendly LEDs 2) It shall consist of red, green, and blue colored LED lights. 3) In normal condition, no light shall be lit. If the patient makes a nurse call, a red light shall be lit. After the nurse call, when the nurse presses the green presence button on the Call Unit, the light of the Over Door Light will turn green. 4) In Code Blue, the blue light shall be lit. 5) The outer casing of the Over Door Light shall be made of nonflammable PC- ABS-FR materials. 6) Over Door Light I/O shall have 2 ports for RJ45 endings for cabling in a chain with call units on one of the communication lines of the Zone Controller or a Room Control unit. 7) Its connection shall be made with Cat 6 UTP cable and RJ45 of B standard. Approved makes: ZKR, HAMPTON, AUSCOM,AUSTCO

31

-

-

... More
BEDSIDE CALL UNIT:- 1) The unit shall be mounted on headboards where there are patient headboards or on the walls where it can be implemented within the system. 2) The unit has 2 Input/Output ports for RJ45 endings to directly connect to a Room Control Unit or for cabling in a chain with Over Door Lights and other call units and eventually to one Zone Controller. 3) On the standard Bed Side Call Unit front side there shall be; 4) A “start call” button with a red nurse symbol. 5) An “end call” button with a green tick mark symbol. 6) Reassurance backlight in order to give visual information about the call status. 7) Continuous backlight for easy visibility of the unit at night. 8) Pressing on the End Call button ends the call and turns the assigned overdoor light to green. IP System Controller logs the event as “Presence”. 9) Pressing the End Call button for the second time ends the “Presence” and turns off the assigned Overdoor light. 10) Pressing the Start Call button when there is “Presence” shall start an “Emergency Call” 11) Pressing the End Call button when there is “Emergency” shall end the “Emergency” and returns to initial “Presence”. 12) The Bedside Call Unit shall be made from nonflammable PC-ABS-FR materials. 13) It can be used individually as a call button where basic patient handset is not needed. Otherwise, its connection with the basic patient handset shall be easily established by connecting via RJ45. 14) A nurse call shall be initiated via the patient handset or the Bedside Call Unit. These two buttons shall be accepted by the system as equivalent. In the event that these buttons are pressed: 15) If the unit is able to transmit the call to the zone controller, the LED on the unit shall flash with 1.0-second intervals. Call transmission information shall be audibly notified to the patient. 16) If there is an error in call transmission, a continuous red light showing the error status shall only stop when the call termination button is pressed or room control connection is made. Subsequent presses of the button shall trigger an audio alert each time. 17) Its connection shall be made with Cat 6 UTP cable and RJ45 of B standard. Approved makes: ZKR, HAMPTON, AUSCOM,AUSTCO

390

-

-

... More
PATIENT HANDSET – Basic:- 1) This handset shall be used in beds in multibed ward areas. 2) It shall be ergonomically suitable to be handheld. 3) It shall be connected to the Bedside Call Unit with an independent cable. 4) On its front side there shall be; 5) A “start call” button with a red nurse symbol. 6) Reassurance LED light in order to give visual information about the call status. 7) Continuous LED light for easy visibility at night. 8) Call initiation and error notification procedures is the same as Bedside Call Unit except audio alerts are always issued by the Bedside Call Unit. Its call initiation button and call backlight work in parallel with the ones on the Bedside Call Unit. 9) Patient handset shall be made from nonflammable PC-ABS-FR materials Approved makes: ZKR, HAMPTON, AUSCOM,AUSTCO

390

-

-

... More
PULL-CORD CALL UNIT (WC/BATHROOM)::- 1) The Pull-cord Call Unit has 2 Input/Output ports for RJ45 endings to directly connect to a Room Control Unit or for cabling in a chain with Over Door Lights and other call units 2) On its front side, there shall be: 3) A call pull-cord with customizable length with minimum 1.5 meters to serve as a call-cord. 4) A call termination button (indicated by a green tick mark symbol) 5) Reassurance backlight in order to give visual information about the call status. 6) Continuous backlight for easy visibility of the unit at night. 7) A priority WC Emergency Call shall start when the cord is pulled turn the assigned overdoor light to red 8) Pressing on the End Call button ends the call and turns the assigned overdoor light to green. IP System Controller logs the event as “Presence”. 9) Pressing the End Call button for the second time ends the “Presence” and turns off the assigned Overdoor light. 10) Pulling the pull-cord when there is “Presence” shall start an “Emergency Call” 11) Pressing the End Call button when there is “Emergency” shall end the “Emergency” and returns to initial “Presence”. 12) Its connection shall be made with CAT6 UTP cable and RJ45 of B standard. Approved makes: ZKR, HAMPTON, AUSCOM,AUSTCO

101

-

-

... More
IN-WARD NURSE PANEL With STAND:- 1) This unit shall be used inside multi-bed areas that are covered with a Zone Controller with Nurse Desks located within the ward area. 2) The unit shall have a minimum 10” touchscreen. 3) The Unit shall be used to monitor the status of every assigned call point’s call and alarm status. 4) The origin room and bed information of all active nurse calls, code blue calls shall be shown with an audiovisual alert along with the call type. 5) Onscreen call points shall have notifications of relevant icons, colors, and tones according to their call status. 6) Calls shall be shown real-time. 7) Timestamp and error logs for situations when the energy supply of the panel is cut or there is no network connection shall be recorded on the IP System Controller. 8) If a call on the nurse panel is not responded to within a determinable amount of time, the call should be able to automatically be forwarded to other nurse panels. Panels can also be set to function as mirror panels either manually or automatically based on time of day. 9) If a panel needs to be changed, the new panel only needs to be given the old panel’s IP information, and this shall be enough to configure the panel. The other settings can be automatically configured from the IP System Controller. 10) The Unit shall have an embedded personnel locator built-in provided without external modules or locators. 11) Embedded personnel locators shall work with Staff Badges and Wristbands Call Units to log the Nurse and Patient presences to closest In-ward nurse panel or room control unit without any external infrastructure support. 12) The Power supply of the Unit shall be PoE+. Approved makes: ZKR, HAMPTON, AUSCOM,AUSTCO

11

-

-

... More
IP SYSTEM CONTROLLER SOFTWARE AND HARDWARE:- 1) The IP System Controller shall be planned as a structure to operate without interruption. 2) The IP System Controller interface shall include all system settings for nurse call and emergency code calls; it shall manage, direct, log, and report all calls and provide statistics. 3) The system shall have a separate password protected web-based interface for management and log reporting. 4) Areas, services, rooms within the hospital, telephone numbers and addresses, nurses, code teams, and user information shall be updated in the management interface. 5) There shall be a table showing active/passive status of all system devices. Devices that are nonoperational due to problems such as power, network connection, or other issues shall be automatically detected. 6) The IP System Controller may test all or selected devices identified in the system with one process. Test results shall be reported. In case of errors, error information may be notified. 7) Call types, locations, timestamps, and response durations shall be reported in the reporting interface. 8) If a call is not responded to within a time period configured based on call type, it shall be cancelled and recorded as a non-responded call and escalated if requested by the institution. 9) All calls shall be received on a single reporting system. 10) Log reports shall be constructed in a way to maintain records for minimum 10 years. Approved makes: ZKR, HAMPTON, AUSCOM,AUSTCO

1

-

-

... More
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC

850

-

-

... More
Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC

8150

-

-

... More
Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC

9150

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.