Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Pradhan Mantri Gram Sadak Yojana - PMGSY Tender

Works
Civil And Construction
Road Construction
Eprocure
Opening Date29 Nov 2024
Closing Soon23 Dec 2024
Tender AmountRefer Documents 
Notes
Download

Costs

  • EMD

    ₹ 22,00,000
  • Document Cost

    ₹ 29,500
  • Tender Fee

    ₹ 500

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. (B) In area of thorny jungle

0.45

-

-

... More
Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross - sections, and transporting to the embankment location with a lift up to 1.5 m and lead Above 1000 m as per Technical Specification Clause 302.3

3763.4

-

-

... More
Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, transporting to embankment site with a lift upto 1.5 m and lead upto 1000 m, trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections as per Technical Specification Clause 302.3.5

1098.6

-

-

... More
Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5

3403.4

-

-

... More
Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5

5944.52

-

-

... More
Construction of Shoulders as per Technical Specification Clause 407. B) Hard Murum Shoulder

714.96

-

-

... More
Pavement Works (GSB, WBM, Bituminous Works) and Cement Concrete Pavement Work

-

-

-

... More
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.(A) By Mix in Place Method (Grading II Material & 100% crushed aggregate)

1792.5

-

-

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 2 as per Technical Specification Clause 405. crushable screening For - By Mechanical Means (100% crushed aggregate)

5.16

-

-

... More
Construction of modified penetration macadam 50mm thick over prepared base by providing a layer of compacted crushed coarse aggregate using chips spreader with alternate applications of bituminous binder of VG-30 Grade @1.75kg/sq.meter and key aggregates and rolling with a three wheel 80-100 kN static roller to achieve the desired degree of compaction as per Technical Specification Clause 506.(VG-30 bulk bitumen rates are considered to arrive at rates)

34.38

-

-

... More
Providing and laying White Topping/Short Paneled Concrete as per IRC-SP 76-2015 (Existing surface preparation to be done if necessary either by milling or leveling course with DLC to correct surface profile and to be paid separately) with un reinforced M-40 grade Pavement Quality Concrete using Ordinary Portland Cement 43/53 Grade OR Portland Pozzolona Cement IS-1489 at 425kg/cum, coarse aggregate, fine aggregate(VSI) and Admixture confirming to IS 9130-1999 (R-2004) polymeric synthetic fiber as per ASTM (1116) such as polyester / polyethylene / polypropylene / Glass fiber at 1.20 kg/cum, mixed in batching and mixing plant or weigh batcher as per approved mix design to achieve minimum flexural strength or modulus of rupture of concrete 4.50 MPa at 28 days limiting maximum water cement ratio to 0.40, transported to site, laid with fixed form/ slip form paver finisher (preferably with slip form paver finisher), spread, vibrated, compacted and finished in a continuous operation to the lines and grades as per drawing, texture finishing of surface, spraying two layers of curing compound, curing with water sprayed on hessian cloth covered over concrete surface, groove cutting grid 1m x 1m or as directed by Engineer Incharge to a depth of 1/3 to 1/4 of the Thickness and of width 3-5 mm as per design including cost of all material, side form work, labour and machineries etc. complete as per specifications.(Excluding Dowel Bars and Tie Bars)(Crushed VSI Sand) Including Polythene Sheet of 125 Micron

1716.81

-

-

... More
Construction of dry lean cement concrete Sub-base over a prepared sub-grade with coarse and fine aggregate conforming to 15: 383, the size of coarse aggregate not exceeding 25 mm., cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor /by suitable means as approved by Engineer-in-charge, compacting with vibratory roller, finishing, curing and including preparation of sub-grade surface if required etc. complete.

1233.91

-

-

... More
Providing and fixing in position 25mm dia anti corossive MS dowel bars of required Dia. 60 cms. Long and at 30.00 cm. C/C and wherever directed including handling, straightening, necessary cutting supported by chairs with proper alignment with half length covered by polythene sheathing including cap etc. complete.

184

-

-

... More
Providing and fixing in position anti corrossive TMT FE 500, tie bars of 12 mm dia. 70 cms. long and at 30.00 cm. C/C and wherever directed including handling, straightening, necessary cutting, handling, straightening , supported by assembly of TMT FE 500, chairs with proper alignment etc. complete.

10000

-

-

... More
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared dry and hungry bituminous surface cleaned with Hydraulic broom as per Technical Specification MORD 2014Clause 503.

34.38

-

-

... More
Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. For -Case - II By Mechanical Means Bitumen (S-65) VG-30

34.38

-

-

... More
Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510. Case - I : Type A Bitumen (S-65) VG-30 by Mechanical Means (emulsion SS 2)

34.38

-

-

... More
Cross Drainage Structures (Culverts & Minor Bridges), Drains and Protection Works

-

-

-

... More
Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal with all lift and lead, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary soil

339.93

-

-

... More
Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal with all lift and lead, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary rock (not requiring blasting) Upto 3 m depth

106.25

-

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 -P.C.C M-10(Crushed Sand)

93.95

-

-

... More
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 - P.C.C grade M 15 Nominal mix(1:2.5:5) (Crushed Sand)

529.46

-

-

... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7. A.C. pipe 100 mm Dia

62

-

-

... More
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. B. 1000 mm HP Drain NP3 Class As per Technical Specification MORD 2014 Cluase No. 1100

75

-

-

... More
Lowering, laying and jointing in proper grade and alignment R.C.C. pipes with collar joints in C.M.1:1 proportion or socketed R.C.C. pipes with rubber joints (excluding cost of rubber ring or R.C.C. collar,) including cost of conveyance from stores to site of work, cost of jointing material, labour, etc. complete as directed by Engineerin- charge (For all class of pipes.) as per IS- 783-1985.

50

-

-

... More
Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 1000mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete

20

-

-

... More
Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 600mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.

55

-

-

... More
Providing ISI standard R.C.C. pipes in standard lengths of following class and diameter suitable for either collar joints or rubber ring joints, excluding GST lev-ied by GOI & GOM in all respect including inspec- tion charges, transport to departmental stores, unloading and stacking etc. complete as per IS-458/1988. 300 mm NP3

50

-

-

... More
Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surfaces as per drawing and Technical Specification Clause 1701

9

-

-

... More
Printing new letters and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade as per drawings and Technical Specification Clause 1701

800

-

-

... More
Maintenance of Causeway by way of minor Surface repairs, replacing Guide Posts, repair of flood gauges, removal of debris, providing boulders and protection work and painting as per technical specification Clause 1909

21

-

-

... More
Traffic Signs, Markings and Road Appurtenances, Road Safety & Road Furniture

-

-

-

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014 Clause 1703 Ordinary Kilometer Stone (Precast)

3

-

-

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014 Clause 1703 200 m stone (precast)

12

-

-

... More
Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704

704

-

-

... More
Providing and fixing of typical PMGSY Retro Reflective information board as per as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing.Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottom duly rivetted with MS angles of 35 x 35 x 5 mm thick M.S angle shall be welded by two vertical M.S angle of 5 mm thick to 75 mm x 75 mm of 12 SWG square tubes / 75mm Dia Pipe posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 75mm, below ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2022. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 7 years for Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4 and as directed by Engineer-In-charge. . A warranty for 7 years for the Retro reflective sheeting for Class-B respectively, from original manufacturer shall be submitted by contractor.

2

-

-

... More
Providing and fixing Retro Reflective MMGSY / PMGSY LOGO informatory sign board with Logo as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circular and drawing. The board will be a composite unit consisting of Two Plates of ACP (Aluminum Composite Panel), material specifications as per clause 17001.3. The top most plate will be of 3 mm ACP in diamond shape of 600x600mm size, riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. The Lower plate will be of 4mm ACP of 1100x300mm size riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. Riveting of all the sheets over angle and flat iron frame will be done neatly to have plain surface on one side. The angle iron frame of Both the plates will be welded to a 75mm x75mmx 12swg Mild steel post at / Tube Centre and this post will be embeded in cement concrete M15 grade block of 450x450x600mm below ground level. The height of the bottom of the lower plate will be 1200mm from normal ground level. The spacing between the diamond shaped plate and Lower Plate is kept 150mm. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2022. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 7 years for Class B sheeting respectively for traffic colors.”All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY signage manual Fig.1 (A) and Fig.1 (B) and as directed by Engineer in-charge. A warranty for 7 years for the Retro reflective sheeting for Class-B respectively, from original manufacturer shall be submitted by contractor.

2

-

-

... More
Providing and erecting direction and place identification retro-\reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on mild steel angle iron posts 75 mm x 75 mm x 6 mm, 2 Nos. firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701

2.16

-

-

... More
Providing and fixing of typical MMGSY / PMGSY Retro Reflective information board as per section 1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing.The ACP sheets of 3 mm thick, of 1500mmx900 mm size duly rivetted with MS angles of 25 x 25 x 5 mm thick M.S angle. Riveting of all the sheets over angle and flat iron frame will be done neatly to have plain surface on one side. The angle iron frame of the plate will be welded to two nos. 75mm x75mm (12 SWG) sheet tubes posts placed at 1125mm apart centre to centre. These two posts will be embeded in cement concrete M15 grade block of 600x600x750mm below ground level. The height of the bottom of the plate will be 775mm from normal ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2022. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 7 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 7 years for Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-B grade as per the latest MORD section 1700 specifications. All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.5 and as directed by Engineer-In-charge. . A warranty for 7 years for the Retro reflective sheeting for Class-B respectively, from original manufacturer shall be submitted by contractor.

1

-

-

... More
Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area not exceeding 0.9 sqm supported on a mild steel single angle iron post 75 x 75 x 6 mm firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 x 450 x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701. Retro-reflectorised Traffic Signs

18.71

-

-

... More
Road Delineators: Supplying and installation of delineators (Roadway Indicators, Hazard markers, Object markers) 80 to 100 cm high above ground level, painted black and white in 15 cm wide strips, fitted with 80x100mm rectangular or 75mm dia. Circular reflectorised panels at the top, buried or pressed into the ground and confirming to I.R.C. 79 and the drawings.

54

-

-

... More
Providing and fixing of road stud 100 x 100 mm die cast in aluminium, resistant to corrosive effect of salt and grit, fitted with lense reflectors, installed in concrete or asphaltic surface by drilling holes 30 mm upto a depth of 600 mm and bedded in a suitable bituminous grout or epoxy mortar, all as per BS:873 (Part 4) 1973.

54

-

-

... More
Providing and Laying hot applied thermoplastic road marking strip on Bituminous Surface of specified shade/ colour of 2.5 mm thick including 1.5 Refractive index reflectorizing glass beads @ 250gm/sqm .Thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC 35:2015. Initial Dry reflectivity RL shall be 250 mcd/sqm/lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/sqm/ lux and Qd of 100 mcd/sqm/ lux measured at the end of 2 years by means of a Standard Reflectometer of Zehntner, Easylux, Delta make capable of measuring RL & QD both according to IRC 35:2015 clause 15.5. The finished surface to be level, uniform, and free from streaks and holes complete as per direction of Engineer-in-charge and in accordance with applicable specifications.(Refer MORTH Clause 803 for technical Specification and Performance for IRC 35:2015).

69.6

-

-

... More
Improvement & 10 Year Maintenance of Palkhed To Wavi Road (KM 0/000-3/600) (MRL-24,VR-30), Block-Niphad, District-Nashik

-

-

-

... More
Site Clearance, Dismantling and Earth Works

-

-

-

... More
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. (A) In area of Non - thorny jungle

2.16

-

-

... More
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. (B) In area of thorny jungle

0.54

-

-

... More
Scarifying the existing bituminous road surface to a depth of 150 mm and disposal of scarified material with a lift upto 3 m and lead upto 1000 m as per Technical Specification Clause 301.4.

10800

-

-

... More
Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross - sections, and transporting to the embankment location with a lift up to 1.5 m and lead Above 1000 m as per Technical Specification Clause 302.3

7469.28

-

-

... More
Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, transporting to embankment site with a lift upto 1.5 m and lead upto 1000 m, trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections as per Technical Specification Clause 302.3.5

961.32

-

-

... More
Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5

4782.3

-

-

... More
Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5

5160.74

-

-

... More
Construction of Shoulders as per Technical Specification Clause 407. B) Hard Murum Shoulder

1404

-

-

... More
Pavement Works (GSB, WBM, Bituminous Works) and Cement Concrete Pavement Work

-

-

-

... More
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.(A) By Mix in Place Method (Grading II Material & 100% crushed aggregate)

1195.96

-

-

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 2 as per Technical Specification Clause 405. crushable screening For - By Mechanical Means (100% crushed aggregate)

5.16

-

-

... More
Construction of modified penetration macadam 50mm thick over prepared base by providing a layer of compacted crushed coarse aggregate using chips spreader with alternate applications of bituminous binder of VG-30 Grade @1.75kg/sq.meter and key aggregates and rolling with a three wheel 80-100 kN static roller to achieve the desired degree of compaction as per Technical Specification Clause 506.(VG-30 bulk bitumen rates are considered to arrive at rates)

34.38

-

-

... More
Providing and laying White Topping/Short Paneled Concrete as per IRC-SP 76-2015 (Existing surface preparation to be done if necessary either by milling or leveling course with DLC to correct surface profile and to be paid separately) with un reinforced M-40 grade Pavement Quality Concrete using Ordinary Portland Cement 43/53 Grade OR Portland Pozzolona Cement IS-1489 at 425kg/cum, coarse aggregate, fine aggregate(VSI) and Admixture confirming to IS 9130-1999 (R-2004) polymeric synthetic fiber as per ASTM (1116) such as polyester / polyethylene / polypropylene / Glass fiber at 1.20 kg/cum, mixed in batching and mixing plant or weigh batcher as per approved mix design to achieve minimum flexural strength or modulus of rupture of concrete 4.50 MPa at 28 days limiting maximum water cement ratio to 0.40, transported to site, laid with fixed form/ slip form paver finisher (preferably with slip form paver finisher), spread, vibrated, compacted and finished in a continuous operation to the lines and grades as per drawing, texture finishing of surface, spraying two layers of curing compound, curing with water sprayed on hessian cloth covered over concrete surface, groove cutting grid 1m x 1m or as directed by Engineer Incharge to a depth of 1/3 to 1/4 of the Thickness and of width 3-5 mm as per design including cost of all material, side form work, labour and machineries etc. complete as per specifications.(Excluding Dowel Bars and Tie Bars)(Crushed VSI Sand) Including Polythene Sheet of 125 Micron

2052.37

-

-

... More
Construction of dry lean cement concrete Sub-base over a prepared sub-grade with coarse and fine aggregate conforming to 15: 383, the size of coarse aggregate not exceeding 25 mm., cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor /by suitable means as approved by Engineer-in-charge, compacting with vibratory roller, finishing, curing and including preparation of sub-grade surface if required etc. complete.

1685.05

-

-

... More
Providing and fixing in position 25mm dia anti corossive MS dowel bars of required Dia. 60 cms. Long and at 30.00 cm. C/C and wherever directed including handling, straightening, necessary cutting supported by chairs with proper alignment with half length covered by polythene sheathing including cap etc. complete.

219

-

-

... More
Providing and fixing in position anti corrossive TMT FE 500, tie bars of 12 mm dia. 70 cms. long and at 30.00 cm. C/C and wherever directed including handling, straightening, necessary cutting, handling, straightening , supported by assembly of TMT FE 500, chairs with proper alignment etc. complete.

12000

-

-

... More
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared dry and hungry bituminous surface cleaned with Hydraulic broom as per Technical Specification MORD 2014Clause 503.

34.38

-

-

... More
Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. For -Case - II By Mechanical Means Bitumen (S-65) VG-30

34.38

-

-

... More
Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510. Case - I : Type A Bitumen (S-65) VG-30 by Mechanical Means (emulsion SS 2)

34.38

-

-

... More
Cross Drainage Structures (Culverts & Minor Bridges), Drains and Protection Works

-

-

-

... More
Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal with all lift and lead, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary soil

153.68

-

-

... More
Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal with all lift and lead, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary rock (not requiring blasting) Upto 3 m depth

31.8

-

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 -P.C.C M-10(Crushed Sand)

37.47

-

-

... More
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 - P.C.C grade M 15 Nominal mix(1:2.5:5) (Crushed Sand)

199.53

-

-

... More
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. B. 1000 mm HP Drain NP3 Class As per Technical Specification MORD 2014 Cluase No. 1100

45

-

-

... More
Lowering, laying and jointing in proper grade and alignment R.C.C. pipes with collar joints in C.M.1:1 proportion or socketed R.C.C. pipes with rubber joints (excluding cost of rubber ring or R.C.C. collar,) including cost of conveyance from stores to site of work, cost of jointing material, labour, etc. complete as directed by Engineerin- charge (For all class of pipes.) as per IS- 783-1985.

100

-

-

... More
Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 1000mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete

25

-

-

... More
Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 600mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.

75

-

-

... More
Providing ISI standard R.C.C. pipes in standard lengths of following class and diameter suitable for either collar joints or rubber ring joints, excluding GST lev-ied by GOI & GOM in all respect including inspec- tion charges, transport to departmental stores, unloading and stacking etc. complete as per IS-458/1988. 300 mm NP3

100

-

-

... More
Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surfaces as per drawing and Technical Specification Clause 1701

5.4

-

-

... More
Printing new letters and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade as per drawings and Technical Specification Clause 1701

480

-

-

... More
Maintenance of Hume pipe Culvert by way of Clearing, Cleaning, Erosion repair, repairs to cracks, parapet wall and protection work as per drawing and technical specification Clause 1908

5

-

-

... More
Maintenance of Slab type Culverts by way of clearing, Cleaning, Erosion repair, repairs to cracks, parapet walls and Protection works as per drawing and technical specification Clasue 1908

1

-

-

... More
Traffic Signs, Markings and Road Appurtenances, Road Safety & Road Furniture

-

-

-

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014 Clause 1703 Ordinary Kilometer Stone (Precast)

4

-

-

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014 Clause 1703 200 m stone (precast)

14

-

-

... More
Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704

477

-

-

... More
Providing and fixing of typical PMGSY Retro Reflective information board as per as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing.Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottom duly rivetted with MS angles of 35 x 35 x 5 mm thick M.S angle shall be welded by two vertical M.S angle of 5 mm thick to 75 mm x 75 mm of 12 SWG square tubes / 75mm Dia Pipe posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 75mm, below ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2022. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 7 years for Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4 and as directed by Engineer-In-charge. . A warranty for 7 years for the Retro reflective sheeting for Class-B respectively, from original manufacturer shall be submitted by contractor.

2

-

-

... More
Providing and fixing Retro Reflective MMGSY / PMGSY LOGO informatory sign board with Logo as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circular and drawing. The board will be a composite unit consisting of Two Plates of ACP (Aluminum Composite Panel), material specifications as per clause 17001.3. The top most plate will be of 3 mm ACP in diamond shape of 600x600mm size, riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. The Lower plate will be of 4mm ACP of 1100x300mm size riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. Riveting of all the sheets over angle and flat iron frame will be done neatly to have plain surface on one side. The angle iron frame of Both the plates will be welded to a 75mm x75mmx 12swg Mild steel post at / Tube Centre and this post will be embeded in cement concrete M15 grade block of 450x450x600mm below ground level. The height of the bottom of the lower plate will be 1200mm from normal ground level. The spacing between the diamond shaped plate and Lower Plate is kept 150mm. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2022. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 7 years for Class B sheeting respectively for traffic colors.”All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY signage manual Fig.1 (A) and Fig.1 (B) and as directed by Engineer in-charge. A warranty for 7 years for the Retro reflective sheeting for Class-B respectively, from original manufacturer shall be submitted by contractor.

2

-

-

... More
Providing and erecting direction and place identification retro-\reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on mild steel angle iron posts 75 mm x 75 mm x 6 mm, 2 Nos. firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701

1.08

-

-

... More
Providing and fixing of typical MMGSY / PMGSY Retro Reflective information board as per section 1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing.The ACP sheets of 3 mm thick, of 1500mmx900 mm size duly rivetted with MS angles of 25 x 25 x 5 mm thick M.S angle. Riveting of all the sheets over angle and flat iron frame will be done neatly to have plain surface on one side. The angle iron frame of the plate will be welded to two nos. 75mm x75mm (12 SWG) sheet tubes posts placed at 1125mm apart centre to centre. These two posts will be embeded in cement concrete M15 grade block of 600x600x750mm below ground level. The height of the bottom of the plate will be 775mm from normal ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2022. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 7 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 7 years for Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-B grade as per the latest MORD section 1700 specifications. All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.5 and as directed by Engineer-In-charge. . A warranty for 7 years for the Retro reflective sheeting for Class-B respectively, from original manufacturer shall be submitted by contractor.

1

-

-

... More
Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area not exceeding 0.9 sqm supported on a mild steel single angle iron post 75 x 75 x 6 mm firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 x 450 x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701. Retro-reflectorised Traffic Signs

18.71

-

-

... More
Road Delineators: Supplying and installation of delineators (Roadway Indicators, Hazard markers, Object markers) 80 to 100 cm high above ground level, painted black and white in 15 cm wide strips, fitted with 80x100mm rectangular or 75mm dia. Circular reflectorised panels at the top, buried or pressed into the ground and confirming to I.R.C. 79 and the drawings.

49

-

-

... More
Providing and fixing of road stud 100 x 100 mm die cast in aluminium, resistant to corrosive effect of salt and grit, fitted with lense reflectors, installed in concrete or asphaltic surface by drilling holes 30 mm upto a depth of 600 mm and bedded in a suitable bituminous grout or epoxy mortar, all as per BS:873 (Part 4) 1973.

140

-

-

... More
Providing and Laying hot applied thermoplastic road marking strip on Bituminous Surface of specified shade/ colour of 2.5 mm thick including 1.5 Refractive index reflectorizing glass beads @ 250gm/sqm .Thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC 35:2015. Initial Dry reflectivity RL shall be 250 mcd/sqm/lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/sqm/ lux and Qd of 100 mcd/sqm/ lux measured at the end of 2 years by means of a Standard Reflectometer of Zehntner, Easylux, Delta make capable of measuring RL & QD both according to IRC 35:2015 clause 15.5. The finished surface to be level, uniform, and free from streaks and holes complete as per direction of Engineer-in-charge and in accordance with applicable specifications.(Refer MORTH Clause 803 for technical Specification and Performance for IRC 35:2015).

103.4

-

-

... More
Improvement & 10 Year Maintenance of Pimapalgaon Baswant To Ahergaon To Shirwade Wani Road (KM 3/200-9/100) (MRL-25,VR-37,38), Block-Niphad, District-Nashik

-

-

-

... More
Site Clearance, Dismantling and Earth Works

-

-

-

... More
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. (A) In area of Non - thorny jungle

3.54

-

-

... More
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. (B) In area of thorny jungle

0.89

-

-

... More
Scarifying existing granular surface to a depth of 50 mm and disposal of scarified material with a lift upto 3 m and leads upto 1000 m as per Technical Specification Clause 301.4.

1475

-

-

... More
Scarifying the existing bituminous road surface to a depth of 150 mm and disposal of scarified material with a lift upto 3 m and lead upto 1000 m as per Technical Specification Clause 301.4.

15460

-

-

... More
Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross - sections, and transporting to the embankment location with a lift up to 1.5 m and lead Above 1000 m as per Technical Specification Clause 302.3

10281.68

-

-

... More
Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, transporting to embankment site with a lift upto 1.5 m and lead upto 1000 m, trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections as per Technical Specification Clause 302.3.5

882

-

-

... More
Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5

8184.94

-

-

... More
Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5

7054.09

-

-

... More
Construction of Shoulders as per Technical Specification Clause 407. B) Hard Murum Shoulder

1370.81

-

-

... More
Pavement Works (GSB, WBM, Bituminous Works) and Cement Concrete Pavement Work

-

-

-

... More
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.(A) By Mix in Place Method (Grading II Material & 100% crushed aggregate)

1062.63

-

-

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 2 as per Technical Specification Clause 405. crushable screening For - By Mechanical Means (100% crushed aggregate)

613.02

-

-

... More
Construction of modified penetration macadam 50mm thick over prepared base by providing a layer of compacted crushed coarse aggregate using chips spreader with alternate applications of bituminous binder of VG-30 Grade @1.75kg/sq.meter and key aggregates and rolling with a three wheel 80-100 kN static roller to achieve the desired degree of compaction as per Technical Specification Clause 506.(VG-30 bulk bitumen rates are considered to arrive at rates)

34.38

-

-

... More
Providing and laying White Topping/Short Paneled Concrete as per IRC-SP 76-2015 (Existing surface preparation to be done if necessary either by milling or leveling course with DLC to correct surface profile and to be paid separately) with un reinforced M-40 grade Pavement Quality Concrete using Ordinary Portland Cement 43/53 Grade OR Portland Pozzolona Cement IS-1489 at 425kg/cum, coarse aggregate, fine aggregate(VSI) and Admixture confirming to IS 9130-1999 (R-2004) polymeric synthetic fiber as per ASTM (1116) such as polyester / polyethylene / polypropylene / Glass fiber at 1.20 kg/cum, mixed in batching and mixing plant or weigh batcher as per approved mix design to achieve minimum flexural strength or modulus of rupture of concrete 4.50 MPa at 28 days limiting maximum water cement ratio to 0.40, transported to site, laid with fixed form/ slip form paver finisher (preferably with slip form paver finisher), spread, vibrated, compacted and finished in a continuous operation to the lines and grades as per drawing, texture finishing of surface, spraying two layers of curing compound, curing with water sprayed on hessian cloth covered over concrete surface, groove cutting grid 1m x 1m or as directed by Engineer Incharge to a depth of 1/3 to 1/4 of the Thickness and of width 3-5 mm as per design including cost of all material, side form work, labour and machineries etc. complete as per specifications.(Excluding Dowel Bars and Tie Bars)(Crushed VSI Sand) Including Polythene Sheet of 125 Micron

3406.95

-

-

... More
Construction of dry lean cement concrete Sub-base over a prepared sub-grade with coarse and fine aggregate conforming to 15: 383, the size of coarse aggregate not exceeding 25 mm., cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor /by suitable means as approved by Engineer-in-charge, compacting with vibratory roller, finishing, curing and including preparation of sub-grade surface if required etc. complete.

2683.02

-

-

... More
Providing and fixing in position 25mm dia anti corossive MS dowel bars of required Dia. 60 cms. Long and at 30.00 cm. C/C and wherever directed including handling, straightening, necessary cutting supported by chairs with proper alignment with half length covered by polythene sheathing including cap etc. complete.

364

-

-

... More
Providing and fixing in position anti corrossive TMT FE 500, tie bars of 12 mm dia. 70 cms. long and at 30.00 cm. C/C and wherever directed including handling, straightening, necessary cutting, handling, straightening , supported by assembly of TMT FE 500, chairs with proper alignment etc. complete.

19666

-

-

... More
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared dry and hungry bituminous surface cleaned with Hydraulic broom as per Technical Specification MORD 2014Clause 503.

34.38

-

-

... More
Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. For -Case - II By Mechanical Means Bitumen (S-65) VG-30

34.38

-

-

... More
Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510. Case - I : Type A Bitumen (S-65) VG-30 by Mechanical Means (emulsion SS 2)

34.38

-

-

... More
Cross Drainage Structures (Culverts & Minor Bridges), Drains and Protection Works

-

-

-

... More
Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal with all lift and lead, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary soil

768.68

-

-

... More
Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal with all lift and lead, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary rock (not requiring blasting) Upto 3 m depth

266.74

-

-

... More
Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal with all lift and lead, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Hard rock (requiring blasting) Upto 3 m depth including 1.5 m depth in hard rock

54.66

-

-

... More
Dewatering including diversion of stream, providing cofferdams, bunds, etc. as may be necessary for foundation and other parts of the work and bailing out water during and after excavation as required. For abutment for Medium Dewatering

71.6

-

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 -P.C.C M-10(Crushed Sand)

225.78

-

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 -P.C.C M-15(Crushed Sand)

20.1

-

-

... More
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 - P.C.C grade M 15 Nominal mix(1:2.5:5) (Crushed Sand)

934.22

-

-

... More
Filling annular space around footing in rock as per technical specification Clause 1203.4.3. P.C.C M-15(Crushed Sand)

19.64

-

-

... More
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 - R.C.C grade M 20 (Natural sand )

168.76

-

-

... More
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications MORD 2014 Clauses 800, 1205.4 and 1205.5 R.C.C grade M 25 (Natural sand )

6.84

-

-

... More
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 R.C.C grade M 30 (Crushed Sand)

30.11

-

-

... More
Providing and laying cement concrete wearing course M 30 grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3 (Natural sand )

3.92

-

-

... More
TMT BAR Reinforcement Supplying, fitting, and placing TMT bar reinforcement in Superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202

3.52

-

-

... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7. A.C. pipe 100 mm Dia

169

-

-

... More
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. B. 1000 mm HP Drain NP3 Class As per Technical Specification MORD 2014 Cluase No. 1100

95

-

-

... More
Lowering, laying and jointing in proper grade and alignment R.C.C. pipes with collar joints in C.M.1:1 proportion or socketed R.C.C. pipes with rubber joints (excluding cost of rubber ring or R.C.C. collar,) including cost of conveyance from stores to site of work, cost of jointing material, labour, etc. complete as directed by Engineerin- charge (For all class of pipes.) as per IS- 783-1985.

250

-

-

... More
Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 1000mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete

35

-

-

... More
Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 600mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.

115

-

-

... More
Providing ISI standard R.C.C. pipes in standard lengths of following class and diameter suitable for either collar joints or rubber ring joints, excluding GST lev-ied by GOI & GOM in all respect including inspec- tion charges, transport to departmental stores, unloading and stacking etc. complete as per IS-458/1988. 300 mm NP3

250

-

-

... More
Providing Tar paper bearing of approved quality in proper size etc. complete (Rate as per PWD a CSR Nagpur for 2015-16) As per Technical Specification MORD 2014 Cluase No. 1402.

9.54

-

-

... More
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification MORD 3014 Clause 1204.3.8 with Granular material

73.08

-

-

... More
Expansion joint with 25 mm thick bitumenous pad (Rate as per PWD Nagpur CSR for 2015-16)

10.41

-

-

... More
Providing 0.90 meter thick metal mat of rubble oversize metal for specified thickness a per detailed drawing including supplying all materials hand packing rubble spreading metal and hard murum including watering and compaction with power roller etc. complete. Spec. No.: As directed by Engineer in charge

63.33

-

-

... More
Drainage spouts complete as per drawing and technical specifications Clause 1209

4

-

-

... More
Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surfaces as per drawing and Technical Specification Clause 1701

11.74

-

-

... More
Printing new letters and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade as per drawings and Technical Specification Clause 1701

960

-

-

... More
Tubular Steel Railing Providing, fixing and erecting 50 mm dia steel pipe railing in 3 rows duly painted on medium weight steel channels (ISMC series) 100 mm x 50 mm, 1.2 m high above ground, 2 m centre-to-centre, complete as per approved drawings Clause 1706

16.4

-

-

... More
Providing rubble filling of trap/ granite/ quartzite gneiss stones for foundations including filling voids with sand/grit and compaction etc complete.

23.58

-

-

... More
Maintenance of Hume pipe Culvert by way of Clearing, Cleaning, Erosion repair, repairs to cracks, parapet wall and protection work as per drawing and technical specification Clause 1908

1

-

-

... More
Traffic Signs, Markings and Road Appurtenances, Road Safety & Road Furniture

-

-

-

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014 Clause 1703 5th Kilometre Stone (precast)

1

-

-

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014 Clause 1703 Ordinary Kilometer Stone (Precast)

6

-

-

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014 Clause 1703 200 m stone (precast)

24

-

-

... More
Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704

686

-

-

... More
Providing and fixing of typical PMGSY Retro Reflective information board as per as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing.Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottom duly rivetted with MS angles of 35 x 35 x 5 mm thick M.S angle shall be welded by two vertical M.S angle of 5 mm thick to 75 mm x 75 mm of 12 SWG square tubes / 75mm Dia Pipe posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 75mm, below ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2022. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 7 years for Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4 and as directed by Engineer-In-charge. . A warranty for 7 years for the Retro reflective sheeting for Class-B respectively, from original manufacturer shall be submitted by contractor.

2

-

-

... More
Providing and fixing Retro Reflective MMGSY / PMGSY LOGO informatory sign board with Logo as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circular and drawing. The board will be a composite unit consisting of Two Plates of ACP (Aluminum Composite Panel), material specifications as per clause 17001.3. The top most plate will be of 3 mm ACP in diamond shape of 600x600mm size, riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. The Lower plate will be of 4mm ACP of 1100x300mm size riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. Riveting of all the sheets over angle and flat iron frame will be done neatly to have plain surface on one side. The angle iron frame of Both the plates will be welded to a 75mm x75mmx 12swg Mild steel post at / Tube Centre and this post will be embeded in cement concrete M15 grade block of 450x450x600mm below ground level. The height of the bottom of the lower plate will be 1200mm from normal ground level. The spacing between the diamond shaped plate and Lower Plate is kept 150mm. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2022. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 7 years for Class B sheeting respectively for traffic colors.”All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY signage manual Fig.1 (A) and Fig.1 (B) and as directed by Engineer in-charge. A warranty for 7 years for the Retro reflective sheeting for Class-B respectively, from original manufacturer shall be submitted by contractor.

2

-

-

... More
Providing and erecting direction and place identification retro-\reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on mild steel angle iron posts 75 mm x 75 mm x 6 mm, 2 Nos. firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701

3.24

-

-

... More
Providing and fixing of typical MMGSY / PMGSY Retro Reflective information board as per section 1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing.The ACP sheets of 3 mm thick, of 1500mmx900 mm size duly rivetted with MS angles of 25 x 25 x 5 mm thick M.S angle. Riveting of all the sheets over angle and flat iron frame will be done neatly to have plain surface on one side. The angle iron frame of the plate will be welded to two nos. 75mm x75mm (12 SWG) sheet tubes posts placed at 1125mm apart centre to centre. These two posts will be embeded in cement concrete M15 grade block of 600x600x750mm below ground level. The height of the bottom of the plate will be 775mm from normal ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2022. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 7 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 7 years for Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-B grade as per the latest MORD section 1700 specifications. All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.5 and as directed by Engineer-In-charge. . A warranty for 7 years for the Retro reflective sheeting for Class-B respectively, from original manufacturer shall be submitted by contractor.

1

-

-

... More
Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area not exceeding 0.9 sqm supported on a mild steel single angle iron post 75 x 75 x 6 mm firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 x 450 x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701. Retro-reflectorised Traffic Signs

15.99

-

-

... More
Road Delineators: Supplying and installation of delineators (Roadway Indicators, Hazard markers, Object markers) 80 to 100 cm high above ground level, painted black and white in 15 cm wide strips, fitted with 80x100mm rectangular or 75mm dia. Circular reflectorised panels at the top, buried or pressed into the ground and confirming to I.R.C. 79 and the drawings.

58

-

-

... More
Providing and fixing of road stud 100 x 100 mm die cast in aluminium, resistant to corrosive effect of salt and grit, fitted with lense reflectors, installed in concrete or asphaltic surface by drilling holes 30 mm upto a depth of 600 mm and bedded in a suitable bituminous grout or epoxy mortar, all as per BS:873 (Part 4) 1973.

146

-

-

... More
Providing and Laying hot applied thermoplastic road marking strip on Bituminous Surface of specified shade/ colour of 2.5 mm thick including 1.5 Refractive index reflectorizing glass beads @ 250gm/sqm .Thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC 35:2015. Initial Dry reflectivity RL shall be 250 mcd/sqm/lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/sqm/ lux and Qd of 100 mcd/sqm/ lux measured at the end of 2 years by means of a Standard Reflectometer of Zehntner, Easylux, Delta make capable of measuring RL & QD both according to IRC 35:2015 clause 15.5. The finished surface to be level, uniform, and free from streaks and holes complete as per direction of Engineer-in-charge and in accordance with applicable specifications.(Refer MORTH Clause 803 for technical Specification and Performance for IRC 35:2015).

43.8

-

-

... More
Improvement & 10 Year Maintenance of Malsakore To Taluka Border To Tarukhedle (KM 0/000-6/320) (MRL-11,ODR-95,VR-20), Block-Niphad, District-Nashik

-

-

-

... More
Site Clearance, Dismantling and Earth Works

-

-

-

... More
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. (A) In area of Non - thorny jungle

2.03

-

-

... More
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. (B) In area of thorny jungle

0.51

-

-

... More
Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross - sections, and transporting to the embankment location with a lift up to 1.5 m and lead Above 1000 m as per Technical Specification Clause 302.3

13391.64

-

-

... More
Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, transporting to embankment site with a lift upto 1.5 m and lead upto 1000 m, trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections as per Technical Specification Clause 302.3.5

4041

-

-

... More
Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5

9945.61

-

-

... More
Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5

6553.5

-

-

... More
Construction of Shoulders as per Technical Specification Clause 407. B) Hard Murum Shoulder

1550.45

-

-

... More
Pavement Works (GSB, WBM, Bituminous Works) and Cement Concrete Pavement Work

-

-

-

... More
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.(A) By Mix in Place Method (Grading II Material & 100% crushed aggregate)

1781.47

-

-

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 2 as per Technical Specification Clause 405. crushable screening For - By Mechanical Means (100% crushed aggregate)

346.49

-

-

... More
Construction of modified penetration macadam 50mm thick over prepared base by providing a layer of compacted crushed coarse aggregate using chips spreader with alternate applications of bituminous binder of VG-30 Grade @1.75kg/sq.meter and key aggregates and rolling with a three wheel 80-100 kN static roller to achieve the desired degree of compaction as per Technical Specification Clause 506.(VG-30 bulk bitumen rates are considered to arrive at rates)

34.38

-

-

... More
Providing and laying White Topping/Short Paneled Concrete as per IRC-SP 76-2015 (Existing surface preparation to be done if necessary either by milling or leveling course with DLC to correct surface profile and to be paid separately) with un reinforced M-40 grade Pavement Quality Concrete using Ordinary Portland Cement 43/53 Grade OR Portland Pozzolona Cement IS-1489 at 425kg/cum, coarse aggregate, fine aggregate(VSI) and Admixture confirming to IS 9130-1999 (R-2004) polymeric synthetic fiber as per ASTM (1116) such as polyester / polyethylene / polypropylene / Glass fiber at 1.20 kg/cum, mixed in batching and mixing plant or weigh batcher as per approved mix design to achieve minimum flexural strength or modulus of rupture of concrete 4.50 MPa at 28 days limiting maximum water cement ratio to 0.40, transported to site, laid with fixed form/ slip form paver finisher (preferably with slip form paver finisher), spread, vibrated, compacted and finished in a continuous operation to the lines and grades as per drawing, texture finishing of surface, spraying two layers of curing compound, curing with water sprayed on hessian cloth covered over concrete surface, groove cutting grid 1m x 1m or as directed by Engineer Incharge to a depth of 1/3 to 1/4 of the Thickness and of width 3-5 mm as per design including cost of all material, side form work, labour and machineries etc. complete as per specifications.(Excluding Dowel Bars and Tie Bars)(Crushed VSI Sand) Including Polythene Sheet of 125 Micron

3606.3

-

-

... More
Construction of dry lean cement concrete Sub-base over a prepared sub-grade with coarse and fine aggregate conforming to 15: 383, the size of coarse aggregate not exceeding 25 mm., cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor /by suitable means as approved by Engineer-in-charge, compacting with vibratory roller, finishing, curing and including preparation of sub-grade surface if required etc. complete.

2709.33

-

-

... More
Providing and fixing in position 25mm dia anti corossive MS dowel bars of required Dia. 60 cms. Long and at 30.00 cm. C/C and wherever directed including handling, straightening, necessary cutting supported by chairs with proper alignment with half length covered by polythene sheathing including cap etc. complete.

46

-

-

... More
Providing and fixing in position anti corrossive TMT FE 500, tie bars of 12 mm dia. 70 cms. long and at 30.00 cm. C/C and wherever directed including handling, straightening, necessary cutting, handling, straightening , supported by assembly of TMT FE 500, chairs with proper alignment etc. complete.

1833

-

-

... More
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared dry and hungry bituminous surface cleaned with Hydraulic broom as per Technical Specification MORD 2014Clause 503.

34.38

-

-

... More
Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. For -Case - II By Mechanical Means Bitumen (S-65) VG-30

34.38

-

-

... More
Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510. Case - I : Type A Bitumen (S-65) VG-30 by Mechanical Means (emulsion SS 2)

34.38

-

-

... More
Cross Drainage Structures (Culverts & Minor Bridges), Drains and Protection Works

-

-

-

... More
Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal with all lift and lead, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary soil

384.04

-

-

... More
Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal with all lift and lead, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary rock (not requiring blasting) Upto 3 m depth

161.96

-

-

... More
Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal with all lift and lead, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Hard rock (requiring blasting)

51.68

-

-

... More
Dewatering including diversion of stream, providing cofferdams, bunds, etc. as may be necessary for foundation and other parts of the work and bailing out water during and after excavation as required. For abutment for Medium Dewatering

67.92

-

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 -P.C.C M-10(Crushed Sand)

64.81

-

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 -P.C.C M-15(Crushed Sand)

18.96

-

-

... More
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 - P.C.C grade M 15 Nominal mix(1:2.5:5) (Crushed Sand)

388.25

-

-

... More
Filling annular space around footing in rock as per technical specification Clause 1203.4.3. P.C.C M-15(Crushed Sand)

19.48

-

-

... More
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 - P.C.C grade M 20 Nominal mix (1:2:4)(Crushed Sand)

149.1

-

-

... More
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 R.C.C grade M 25 (Crushed Sand)

6.6

-

-

... More
Supplying, fitting, and placing TMT bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202

2.93

-

-

... More
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 R.C.C grade M 30 (Crushed Sand)

23.51

-

-

... More
Providing and laying cement concrete wearing course M 30 grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3 (Crushed Sand)

3.36

-

-

... More
Providing tar paper bearing including laying in proper position etc. complete.

9.54

-

-

... More
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 with Granular material

57.96

-

-

... More
Drainage spouts complete as per drawing and technical specifications Clause 1209

4

-

-

... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7. A.C. pipe 100 mm Dia

48

-

-

... More
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. B. 1000 mm HP Drain NP3 Class As per Technical Specification MORD 2014 Cluase No. 1100

97.5

-

-

... More
Lowering, laying and jointing in proper grade and alignment R.C.C. pipes with collar joints in C.M.1:1 proportion or socketed R.C.C. pipes with rubber joints (excluding cost of rubber ring or R.C.C. collar,) including cost of conveyance from stores to site of work, cost of jointing material, labour, etc. complete as directed by Engineerin- charge (For all class of pipes.) as per IS- 783-1985.

150

-

-

... More
Providing expansion joints with 25mm thick bituminous pad as per detailed drawings etc. complete.

9.62

-

-

... More
Providing and laying 0.90 meter thick metal mat consisting of rubble, oversize metal and normal size metal in specified thickness as per detailed drawing including supplying all materials, hand packing of rubble, spreading metal in layers and hard murum including watering and compaction with power roller etc. complete.

63.44

-

-

... More
Providing, fixing and erecting 50 mm dia steel pipe railing in 3 rows duly painted on medium weight steel channels (ISMC series) 100 mm x 50 mm, 1.2 m high above ground, 2 m centre-to-centre, complete as per approved drawings Clause 1706

14.44

-

-

... More
Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 1000mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete

35

-

-

... More
Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 600mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.

115

-

-

... More
Providing ISI standard R.C.C. pipes in standard lengths of following class and diameter suitable for either collar joints or rubber ring joints, excluding GST lev-ied by GOI & GOM in all respect including inspec- tion charges, transport to departmental stores, unloading and stacking etc. complete as per IS-458/1988. 300 mm NP3

150

-

-

... More
Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surfaces as per drawing and Technical Specification Clause 1701

13.36

-

-

... More
Printing new letters and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade as per drawings and Technical Specification Clause 1701

1120

-

-

... More
Maintenance of Slab type Culverts by way of clearing, Cleaning, Erosion repair, repairs to cracks, parapet walls and Protection works as per drawing and technical specification Clasue 1908

1

-

-

... More
Maintenance of Hume pipe Culvert by way of Clearing, Cleaning, Erosion repair, repairs to cracks, parapet wall and protection work as per drawing and technical specification Clause 1908

5

-

-

... More
Traffic Signs, Markings and Road Appurtenances, Road Safety & Road Furniture

-

-

-

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014 Clause 1703 Ordinary Kilometer Stone (Precast)

6

-

-

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014 Clause 1703 200 m stone (precast)

26

-

-

... More
Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704

751

-

-

... More
Providing rubble filling of trap/ granite/ quartzite gneiss stones for foundations including filling voids with sand/grit and compaction etc complete.

18.7

-

-

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014 Clause 1703 5th Kilometre Stone (precast)

1

-

-

... More
Providing and fixing of typical PMGSY Retro Reflective information board as per as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing.Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottom duly rivetted with MS angles of 35 x 35 x 5 mm thick M.S angle shall be welded by two vertical M.S angle of 5 mm thick to 75 mm x 75 mm of 12 SWG square tubes / 75mm Dia Pipe posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 75mm, below ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2022. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 7 years for Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4 and as directed by Engineer-In-charge. . A warranty for 7 years for the Retro reflective sheeting for Class-B respectively, from original manufacturer shall be submitted by contractor.

2

-

-

... More
Providing and fixing Retro Reflective MMGSY / PMGSY LOGO informatory sign board with Logo as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circular and drawing. The board will be a composite unit consisting of Two Plates of ACP (Aluminum Composite Panel), material specifications as per clause 17001.3. The top most plate will be of 3 mm ACP in diamond shape of 600x600mm size, riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. The Lower plate will be of 4mm ACP of 1100x300mm size riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. Riveting of all the sheets over angle and flat iron frame will be done neatly to have plain surface on one side. The angle iron frame of Both the plates will be welded to a 75mm x75mmx 12swg Mild steel post at / Tube Centre and this post will be embeded in cement concrete M15 grade block of 450x450x600mm below ground level. The height of the bottom of the lower plate will be 1200mm from normal ground level. The spacing between the diamond shaped plate and Lower Plate is kept 150mm. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2022. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 7 years for Class B sheeting respectively for traffic colors.”All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY signage manual Fig.1 (A) and Fig.1 (B) and as directed by Engineer in-charge. A warranty for 7 years for the Retro reflective sheeting for Class-B respectively, from original manufacturer shall be submitted by contractor.

2

-

-

... More
Providing and erecting direction and place identification retro-\reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on mild steel angle iron posts 75 mm x 75 mm x 6 mm, 2 Nos. firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701

2.16

-

-

... More
Providing and fixing of typical MMGSY / PMGSY Retro Reflective information board as per section 1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing.The ACP sheets of 3 mm thick, of 1500mmx900 mm size duly rivetted with MS angles of 25 x 25 x 5 mm thick M.S angle. Riveting of all the sheets over angle and flat iron frame will be done neatly to have plain surface on one side. The angle iron frame of the plate will be welded to two nos. 75mm x75mm (12 SWG) sheet tubes posts placed at 1125mm apart centre to centre. These two posts will be embeded in cement concrete M15 grade block of 600x600x750mm below ground level. The height of the bottom of the plate will be 775mm from normal ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2022. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 7 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 7 years for Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-B grade as per the latest MORD section 1700 specifications. All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.5 and as directed by Engineer-In-charge. . A warranty for 7 years for the Retro reflective sheeting for Class-B respectively, from original manufacturer shall be submitted by contractor.

1

-

-

... More
Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area not exceeding 0.9 sqm supported on a mild steel single angle iron post 75 x 75 x 6 mm firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 x 450 x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701. Retro-reflectorised Traffic Signs

18.71

-

-

... More
Road Delineators: Supplying and installation of delineators (Roadway Indicators, Hazard markers, Object markers) 80 to 100 cm high above ground level, painted black and white in 15 cm wide strips, fitted with 80x100mm rectangular or 75mm dia. Circular reflectorised panels at the top, buried or pressed into the ground and confirming to I.R.C. 79 and the drawings.

44

-

-

... More
Providing and fixing of road stud 100 x 100 mm die cast in aluminium, resistant to corrosive effect of salt and grit, fitted with lense reflectors, installed in concrete or asphaltic surface by drilling holes 30 mm upto a depth of 600 mm and bedded in a suitable bituminous grout or epoxy mortar, all as per BS:873 (Part 4) 1973.

70

-

-

... More
Providing and Laying hot applied thermoplastic road marking strip on Bituminous Surface of specified shade/ colour of 2.5 mm thick including 1.5 Refractive index reflectorizing glass beads @ 250gm/sqm .Thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC 35:2015. Initial Dry reflectivity RL shall be 250 mcd/sqm/lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/sqm/ lux and Qd of 100 mcd/sqm/ lux measured at the end of 2 years by means of a Standard Reflectometer of Zehntner, Easylux, Delta make capable of measuring RL & QD both according to IRC 35:2015 clause 15.5. The finished surface to be level, uniform, and free from streaks and holes complete as per direction of Engineer-in-charge and in accordance with applicable specifications.(Refer MORTH Clause 803 for technical Specification and Performance for IRC 35:2015).

66.8

-

-

... More
Improvement & 10 Year Maintenance of Niphad To Sonewadi Kh.Road (KM 0/000 - 7/700) (MRL-01,VR-143,46), Block-Niphad, District-Nashik

-

-

-

... More
Site Clearance, Dismantling and Earth Works

-

-

-

... More
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. (A) In area of Non - thorny jungle

4.62

-

-

... More
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. (B) In area of thorny jungle

1.16

-

-

... More
Scarifying existing granular surface to a depth of 50 mm and disposal of scarified material with a lift upto 3 m and leads upto 1000 m as per Technical Specification Clause 301.4.

4250

-

-

... More
Scarifying the existing bituminous road surface to a depth of 150 mm and disposal of scarified material with a lift upto 3 m and lead upto 1000 m as per Technical Specification Clause 301.4.

18725

-

-

... More
Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross - sections, and transporting to the embankment location with a lift up to 1.5 m and lead Above 1000 m as per Technical Specification Clause 302.3

12388.2

-

-

... More
Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, transporting to embankment site with a lift upto 1.5 m and lead upto 1000 m, trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections as per Technical Specification Clause 302.3.5

1981.8

-

-

... More
Excavation for roadway in hard rock (requiring blasting) by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross-sections, loading and disposal of cut rock with a lift upto 1.5 m and leads upto 1000 m as per Technical Specification Clause 302.3.5

244.2

-

-

... More
Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5

9826.5

-

-

... More
Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5

11732.47

-

-

... More
Construction of Shoulders as per Technical Specification Clause 407. B) Hard Murum Shoulder

1626

-

-

... More
Pavement Works (GSB, WBM, Bituminous Works) and Cement Concrete Pavement Work

-

-

-

... More
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.(A) By Mix in Place Method (Grading II Material & 100% crushed aggregate)

1556.44

-

-

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 2 as per Technical Specification Clause 405. crushable screening For - By Mechanical Means (100% crushed aggregate)

713.23

-

-

... More
Construction of modified penetration macadam 50mm thick over prepared base by providing a layer of compacted crushed coarse aggregate using chips spreader with alternate applications of bituminous binder of VG-30 Grade @1.75kg/sq.meter and key aggregates and rolling with a three wheel 80-100 kN static roller to achieve the desired degree of compaction as per Technical Specification Clause 506.(VG-30 bulk bitumen rates are considered to arrive at rates)

34.38

-

-

... More
Providing and laying White Topping/Short Paneled Concrete as per IRC-SP 76-2015 (Existing surface preparation to be done if necessary either by milling or leveling course with DLC to correct surface profile and to be paid separately) with un reinforced M-40 grade Pavement Quality Concrete using Ordinary Portland Cement 43/53 Grade OR Portland Pozzolona Cement IS-1489 at 425kg/cum, coarse aggregate, fine aggregate(VSI) and Admixture confirming to IS 9130-1999 (R-2004) polymeric synthetic fiber as per ASTM (1116) such as polyester / polyethylene / polypropylene / Glass fiber at 1.20 kg/cum, mixed in batching and mixing plant or weigh batcher as per approved mix design to achieve minimum flexural strength or modulus of rupture of concrete 4.50 MPa at 28 days limiting maximum water cement ratio to 0.40, transported to site, laid with fixed form/ slip form paver finisher (preferably with slip form paver finisher), spread, vibrated, compacted and finished in a continuous operation to the lines and grades as per drawing, texture finishing of surface, spraying two layers of curing compound, curing with water sprayed on hessian cloth covered over concrete surface, groove cutting grid 1m x 1m or as directed by Engineer Incharge to a depth of 1/3 to 1/4 of the Thickness and of width 3-5 mm as per design including cost of all material, side form work, labour and machineries etc. complete as per specifications.(Excluding Dowel Bars and Tie Bars)(Crushed VSI Sand) Including Polythene Sheet of 125 Micron

4436.76

-

-

... More
Construction of dry lean cement concrete Sub-base over a prepared sub-grade with coarse and fine aggregate conforming to 15: 383, the size of coarse aggregate not exceeding 25 mm., cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor /by suitable means as approved by Engineer-in-charge, compacting with vibratory roller, finishing, curing and including preparation of sub-grade surface if required etc. complete.

3605.54

-

-

... More
Providing and fixing in position 25mm dia anti corossive MS dowel bars of required Dia. 60 cms. Long and at 30.00 cm. C/C and wherever directed including handling, straightening, necessary cutting supported by chairs with proper alignment with half length covered by polythene sheathing including cap etc. complete.

485

-

-

... More
Providing and fixing in position anti corrossive TMT FE 500, tie bars of 12 mm dia. 70 cms. long and at 30.00 cm. C/C and wherever directed including handling, straightening, necessary cutting, handling, straightening , supported by assembly of TMT FE 500, chairs with proper alignment etc. complete.

24667

-

-

... More
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared dry and hungry bituminous surface cleaned with Hydraulic broom as per Technical Specification MORD 2014Clause 503.

34.38

-

-

... More
Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. For -Case - II By Mechanical Means Bitumen (S-65) VG-30

34.38

-

-

... More
Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510. Case - I : Type A Bitumen (S-65) VG-30 by Mechanical Means (emulsion SS 2)

34.38

-

-

... More
Cross Drainage Structures (Culverts & Minor Bridges), Drains and Protection Works

-

-

-

... More
Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal with all lift and lead, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary soil

530.13

-

-

... More
Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal with all lift and lead, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary rock (not requiring blasting) Upto 3 m depth

160.34

-

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 -P.C.C M-10(Crushed Sand)

185.45

-

-

... More
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 - P.C.C grade M 15 Nominal mix(1:2.5:5) (Crushed Sand)

799.99

-

-

... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7. A.C. pipe 100 mm Dia

167

-

-

... More
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. B. 1000 mm HP Drain NP3 Class As per Technical Specification MORD 2014 Cluase No. 1100

52.5

-

-

... More
Lowering, laying and jointing in proper grade and alignment R.C.C. pipes with collar joints in C.M.1:1 proportion or socketed R.C.C. pipes with rubber joints (excluding cost of rubber ring or R.C.C. collar,) including cost of conveyance from stores to site of work, cost of jointing material, labour, etc. complete as directed by Engineerin- charge (For all class of pipes.) as per IS- 783-1985.

250

-

-

... More
Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 1000mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete

50

-

-

... More
Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 600mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.

150

-

-

... More
Providing ISI standard R.C.C. pipes in standard lengths of following class and diameter suitable for either collar joints or rubber ring joints, excluding GST lev-ied by GOI & GOM in all respect including inspec- tion charges, transport to departmental stores, unloading and stacking etc. complete as per IS-458/1988. 300 mm NP3

250

-

-

... More
Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surfaces as per drawing and Technical Specification Clause 1701

6.3

-

-

... More
Printing new letters and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade as per drawings and Technical Specification Clause 1701

560

-

-

... More
Maintenance of Hume pipe Culvert by way of Clearing, Cleaning, Erosion repair, repairs to cracks, parapet wall and protection work as per drawing and technical specification Clause 1908

3

-

-

... More
Traffic Signs, Markings and Road Appurtenances, Road Safety & Road Furniture

-

-

-

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014 Clause 1703 5th Kilometre Stone (precast)

1

-

-

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014 Clause 1703 Ordinary Kilometer Stone (Precast)

8

-

-

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014 Clause 1703 200 m stone (precast)

31

-

-

... More
Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704

910

-

-

... More
Providing and fixing of typical PMGSY Retro Reflective information board as per as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing.Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottom duly rivetted with MS angles of 35 x 35 x 5 mm thick M.S angle shall be welded by two vertical M.S angle of 5 mm thick to 75 mm x 75 mm of 12 SWG square tubes / 75mm Dia Pipe posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 75mm, below ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2022. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 7 years for Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4 and as directed by Engineer-In-charge. . A warranty for 7 years for the Retro reflective sheeting for Class-B respectively, from original manufacturer shall be submitted by contractor.

2

-

-

... More
Providing and fixing Retro Reflective MMGSY / PMGSY LOGO informatory sign board with Logo as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circular and drawing. The board will be a composite unit consisting of Two Plates of ACP (Aluminum Composite Panel), material specifications as per clause 17001.3. The top most plate will be of 3 mm ACP in diamond shape of 600x600mm size, riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. The Lower plate will be of 4mm ACP of 1100x300mm size riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. Riveting of all the sheets over angle and flat iron frame will be done neatly to have plain surface on one side. The angle iron frame of Both the plates will be welded to a 75mm x75mmx 12swg Mild steel post at / Tube Centre and this post will be embeded in cement concrete M15 grade block of 450x450x600mm below ground level. The height of the bottom of the lower plate will be 1200mm from normal ground level. The spacing between the diamond shaped plate and Lower Plate is kept 150mm. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2022. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 7 years for Class B sheeting respectively for traffic colors.”All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY signage manual Fig.1 (A) and Fig.1 (B) and as directed by Engineer in-charge. A warranty for 7 years for the Retro reflective sheeting for Class-B respectively, from original manufacturer shall be submitted by contractor.

2

-

-

... More
Providing and erecting direction and place identification retro-\reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on mild steel angle iron posts 75 mm x 75 mm x 6 mm, 2 Nos. firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701

3.24

-

-

... More
Providing and fixing of typical MMGSY / PMGSY Retro Reflective information board as per section 1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing.The ACP sheets of 3 mm thick, of 1500mmx900 mm size duly rivetted with MS angles of 25 x 25 x 5 mm thick M.S angle. Riveting of all the sheets over angle and flat iron frame will be done neatly to have plain surface on one side. The angle iron frame of the plate will be welded to two nos. 75mm x75mm (12 SWG) sheet tubes posts placed at 1125mm apart centre to centre. These two posts will be embeded in cement concrete M15 grade block of 600x600x750mm below ground level. The height of the bottom of the plate will be 775mm from normal ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2022. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 7 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 7 years for Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-B grade as per the latest MORD section 1700 specifications. All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.5 and as directed by Engineer-In-charge. . A warranty for 7 years for the Retro reflective sheeting for Class-B respectively, from original manufacturer shall be submitted by contractor.

1

-

-

... More
Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area not exceeding 0.9 sqm supported on a mild steel single angle iron post 75 x 75 x 6 mm firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 x 450 x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701. Retro-reflectorised Traffic Signs

15.99

-

-

... More
Road Delineators: Supplying and installation of delineators (Roadway Indicators, Hazard markers, Object markers) 80 to 100 cm high above ground level, painted black and white in 15 cm wide strips, fitted with 80x100mm rectangular or 75mm dia. Circular reflectorised panels at the top, buried or pressed into the ground and confirming to I.R.C. 79 and the drawings.

70

-

-

... More
Providing and fixing of road stud 100 x 100 mm die cast in aluminium, resistant to corrosive effect of salt and grit, fitted with lense reflectors, installed in concrete or asphaltic surface by drilling holes 30 mm upto a depth of 600 mm and bedded in a suitable bituminous grout or epoxy mortar, all as per BS:873 (Part 4) 1973.

294

-

-

... More
Providing and Laying hot applied thermoplastic road marking strip on Bituminous Surface of specified shade/ colour of 2.5 mm thick including 1.5 Refractive index reflectorizing glass beads @ 250gm/sqm .Thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC 35:2015. Initial Dry reflectivity RL shall be 250 mcd/sqm/lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/sqm/ lux and Qd of 100 mcd/sqm/ lux measured at the end of 2 years by means of a Standard Reflectometer of Zehntner, Easylux, Delta make capable of measuring RL & QD both according to IRC 35:2015 clause 15.5. The finished surface to be level, uniform, and free from streaks and holes complete as per direction of Engineer-in-charge and in accordance with applicable specifications.(Refer MORTH Clause 803 for technical Specification and Performance for IRC 35:2015).

69.4

-

-

... More
Improvement & 10 Year Maintenance of SH-35 (Bhendali) To Mahajanpur To Taluka Border Road.(KM 0/000-4/300) (LR-80,VR-276), Block-Niphad, District-Nashik

-

-

-

... More
Site Clearance, Dismantling and Earth Works

-

-

-

... More
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. (A) In area of Non - thorny jungle

2.58

-

-

... More
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. (B) In area of thorny jungle

0.65

-

-

... More
Scarifying existing granular surface to a depth of 50 mm and disposal of scarified material with a lift upto 3 m and leads upto 1000 m as per Technical Specification Clause 301.4.

4340

-

-

... More
Scarifying the existing bituminous road surface to a depth of 150 mm and disposal of scarified material with a lift upto 3 m and lead upto 1000 m as per Technical Specification Clause 301.4.

4982

-

-

... More
Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross - sections, and transporting to the embankment location with a lift up to 1.5 m and lead Above 1000 m as per Technical Specification Clause 302.3

7862.4

-

-

... More
Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, transporting to embankment site with a lift upto 1.5 m and lead upto 1000 m, trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections as per Technical Specification Clause 302.3.5

1005.6

-

-

... More
Excavation for roadway in hard rock (requiring blasting) by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross-sections, loading and disposal of cut rock with a lift upto 1.5 m and leads upto 1000 m as per Technical Specification Clause 302.3.5

244.8

-

-

... More
Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5

6714

-

-

... More
Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5

6597.34

-

-

... More
Construction of Shoulders as per Technical Specification Clause 407. B) Hard Murum Shoulder

924.5

-

-

... More
Pavement Works (GSB, WBM, Bituminous Works) and Cement Concrete Pavement Work

-

-

-

... More
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.(A) By Mix in Place Method (Grading II Material & 100% crushed aggregate)

2827.72

-

-

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 2 as per Technical Specification Clause 405. crushable screening For - By Mechanical Means (100% crushed aggregate)

421.42

-

-

... More
Construction of modified penetration macadam 50mm thick over prepared base by providing a layer of compacted crushed coarse aggregate using chips spreader with alternate applications of bituminous binder of VG-30 Grade @1.75kg/sq.meter and key aggregates and rolling with a three wheel 80-100 kN static roller to achieve the desired degree of compaction as per Technical Specification Clause 506.(VG-30 bulk bitumen rates are considered to arrive at rates)

33.88

-

-

... More
Providing and laying White Topping/Short Paneled Concrete as per IRC-SP 76-2015 (Existing surface preparation to be done if necessary either by milling or leveling course with DLC to correct surface profile and to be paid separately) with un reinforced M-40 grade Pavement Quality Concrete using Ordinary Portland Cement 43/53 Grade OR Portland Pozzolona Cement IS-1489 at 425kg/cum, coarse aggregate, fine aggregate(VSI) and Admixture confirming to IS 9130-1999 (R-2004) polymeric synthetic fiber as per ASTM (1116) such as polyester / polyethylene / polypropylene / Glass fiber at 1.20 kg/cum, mixed in batching and mixing plant or weigh batcher as per approved mix design to achieve minimum flexural strength or modulus of rupture of concrete 4.50 MPa at 28 days limiting maximum water cement ratio to 0.40, transported to site, laid with fixed form/ slip form paver finisher (preferably with slip form paver finisher), spread, vibrated, compacted and finished in a continuous operation to the lines and grades as per drawing, texture finishing of surface, spraying two layers of curing compound, curing with water sprayed on hessian cloth covered over concrete surface, groove cutting grid 1m x 1m or as directed by Engineer Incharge to a depth of 1/3 to 1/4 of the Thickness and of width 3-5 mm as per design including cost of all material, side form work, labour and machineries etc. complete as per specifications.(Excluding Dowel Bars and Tie Bars)(Crushed VSI Sand) Including Polythene Sheet of 125 Micron

3820.07

-

-

... More
Construction of dry lean cement concrete Sub-base over a prepared sub-grade with coarse and fine aggregate conforming to 15: 383, the size of coarse aggregate not exceeding 25 mm., cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor /by suitable means as approved by Engineer-in-charge, compacting with vibratory roller, finishing, curing and including preparation of sub-grade surface if required etc. complete.

2592.67

-

-

... More
Providing and fixing in position 25mm dia anti corossive MS dowel bars of required Dia. 60 cms. Long and at 30.00 cm. C/C and wherever directed including handling, straightening, necessary cutting supported by chairs with proper alignment with half length covered by polythene sheathing including cap etc. complete.

422

-

-

... More
Providing and fixing in position anti corrossive TMT FE 500, tie bars of 12 mm dia. 70 cms. long and at 30.00 cm. C/C and wherever directed including handling, straightening, necessary cutting, handling, straightening , supported by assembly of TMT FE 500, chairs with proper alignment etc. complete.

14333

-

-

... More
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared dry and hungry bituminous surface cleaned with Hydraulic broom as per Technical Specification MORD 2014Clause 503.

33.88

-

-

... More
Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. For -Case - II By Mechanical Means Bitumen (S-65) VG-30

33.88

-

-

... More
Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510. Case - I : Type A Bitumen (S-65) VG-30 by Mechanical Means (emulsion SS 2)

33.88

-

-

... More
Cross Drainage Structures (Culverts & Minor Bridges), Drains and Protection Works

-

-

-

... More
Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal with all lift and lead, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary soil

289.84

-

-

... More
Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal with all lift and lead, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary rock (not requiring blasting) Upto 3 m depth

65.74

-

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 -P.C.C M-10(Crushed Sand)

69.42

-

-

... More
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 - P.C.C grade M 15 Nominal mix(1:2.5:5) (Crushed Sand)

380.14

-

-

... More
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. B. 1000 mm HP Drain NP3 Class As per Technical Specification MORD 2014 Cluase No. 1100

95

-

-

... More
Lowering, laying and jointing in proper grade and alignment R.C.C. pipes with collar joints in C.M.1:1 proportion or socketed R.C.C. pipes with rubber joints (excluding cost of rubber ring or R.C.C. collar,) including cost of conveyance from stores to site of work, cost of jointing material, labour, etc. complete as directed by Engineerin- charge (For all class of pipes.) as per IS- 783-1985.

150

-

-

... More
Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 1000mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete

25

-

-

... More
Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 600mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.

85

-

-

... More
Providing ISI standard R.C.C. pipes in standard lengths of following class and diameter suitable for either collar joints or rubber ring joints, excluding GST lev-ied by GOI & GOM in all respect including inspec- tion charges, transport to departmental stores, unloading and stacking etc. complete as per IS-458/1988. 300 mm NP3

150

-

-

... More
Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surfaces as per drawing and Technical Specification Clause 1701

10.8

-

-

... More
Printing new letters and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade as per drawings and Technical Specification Clause 1701

960

-

-

... More
Traffic Signs, Markings and Road Appurtenances, Road Safety & Road Furniture

-

-

-

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014 Clause 1703 Ordinary Kilometer Stone (Precast)

4

-

-

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014 Clause 1703 200 m stone (precast)

18

-

-

... More
Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704

563

-

-

... More
Providing and fixing of typical PMGSY Retro Reflective information board as per as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing.Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottom duly rivetted with MS angles of 35 x 35 x 5 mm thick M.S angle shall be welded by two vertical M.S angle of 5 mm thick to 75 mm x 75 mm of 12 SWG square tubes / 75mm Dia Pipe posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 75mm, below ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2022. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 7 years for Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4 and as directed by Engineer-In-charge. . A warranty for 7 years for the Retro reflective sheeting for Class-B respectively, from original manufacturer shall be submitted by contractor.

2

-

-

... More
Providing and fixing Retro Reflective MMGSY / PMGSY LOGO informatory sign board with Logo as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circular and drawing. The board will be a composite unit consisting of Two Plates of ACP (Aluminum Composite Panel), material specifications as per clause 17001.3. The top most plate will be of 3 mm ACP in diamond shape of 600x600mm size, riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. The Lower plate will be of 4mm ACP of 1100x300mm size riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. Riveting of all the sheets over angle and flat iron frame will be done neatly to have plain surface on one side. The angle iron frame of Both the plates will be welded to a 75mm x75mmx 12swg Mild steel post at / Tube Centre and this post will be embeded in cement concrete M15 grade block of 450x450x600mm below ground level. The height of the bottom of the lower plate will be 1200mm from normal ground level. The spacing between the diamond shaped plate and Lower Plate is kept 150mm. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2022. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 7 years for Class B sheeting respectively for traffic colors.”All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY signage manual Fig.1 (A) and Fig.1 (B) and as directed by Engineer in-charge. A warranty for 7 years for the Retro reflective sheeting for Class-B respectively, from original manufacturer shall be submitted by contractor.

2

-

-

... More
Providing and erecting direction and place identification retro-\reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on mild steel angle iron posts 75 mm x 75 mm x 6 mm, 2 Nos. firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701

2.16

-

-

... More
Providing and fixing of typical MMGSY / PMGSY Retro Reflective information board as per section 1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing.The ACP sheets of 3 mm thick, of 1500mmx900 mm size duly rivetted with MS angles of 25 x 25 x 5 mm thick M.S angle. Riveting of all the sheets over angle and flat iron frame will be done neatly to have plain surface on one side. The angle iron frame of the plate will be welded to two nos. 75mm x75mm (12 SWG) sheet tubes posts placed at 1125mm apart centre to centre. These two posts will be embeded in cement concrete M15 grade block of 600x600x750mm below ground level. The height of the bottom of the plate will be 775mm from normal ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2022. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 7 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 7 years for Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-B grade as per the latest MORD section 1700 specifications. All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.5 and as directed by Engineer-In-charge. . A warranty for 7 years for the Retro reflective sheeting for Class-B respectively, from original manufacturer shall be submitted by contractor.

1

-

-

... More
Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area not exceeding 0.9 sqm supported on a mild steel single angle iron post 75 x 75 x 6 mm firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 x 450 x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701. Retro-reflectorised Traffic Signs

19.43

-

-

... More
Road Delineators: Supplying and installation of delineators (Roadway Indicators, Hazard markers, Object markers) 80 to 100 cm high above ground level, painted black and white in 15 cm wide strips, fitted with 80x100mm rectangular or 75mm dia. Circular reflectorised panels at the top, buried or pressed into the ground and confirming to I.R.C. 79 and the drawings.

60

-

-

... More
Providing and fixing of road stud 100 x 100 mm die cast in aluminium, resistant to corrosive effect of salt and grit, fitted with lense reflectors, installed in concrete or asphaltic surface by drilling holes 30 mm upto a depth of 600 mm and bedded in a suitable bituminous grout or epoxy mortar, all as per BS:873 (Part 4) 1973.

74

-

-

... More
Providing and Laying hot applied thermoplastic road marking strip on Bituminous Surface of specified shade/ colour of 2.5 mm thick including 1.5 Refractive index reflectorizing glass beads @ 250gm/sqm .Thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC 35:2015. Initial Dry reflectivity RL shall be 250 mcd/sqm/lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/sqm/ lux and Qd of 100 mcd/sqm/ lux measured at the end of 2 years by means of a Standard Reflectometer of Zehntner, Easylux, Delta make capable of measuring RL & QD both according to IRC 35:2015 clause 15.5. The finished surface to be level, uniform, and free from streaks and holes complete as per direction of Engineer-in-charge and in accordance with applicable specifications.(Refer MORTH Clause 803 for technical Specification and Performance for IRC 35:2015).

78.48

-

-

... More
Improvement & 10 Year Maintenance of Songaon To Karanjgaon Road (KM 0/000-3/800) (LR-76,VR-279, 49), Block-Niphad, District-Nashik

-

-

-

... More
Site Clearance, Dismantling and Earth Works

-

-

-

... More
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. (A) In area of Non - thorny jungle

2.28

-

-

... More
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. (B) In area of thorny jungle

0.57

-

-

... More
Scarifying existing granular surface to a depth of 50 mm and disposal of scarified material with a lift upto 3 m and leads upto 1000 m as per Technical Specification Clause 301.4.

2320

-

-

... More
Scarifying the existing bituminous road surface to a depth of 150 mm and disposal of scarified material with a lift upto 3 m and lead upto 1000 m as per Technical Specification Clause 301.4.

9600

-

-

... More
Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross - sections, and transporting to the embankment location with a lift up to 1.5 m and lead Above 1000 m as per Technical Specification Clause 302.3

6677.84

-

-

... More
Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, transporting to embankment site with a lift upto 1.5 m and lead upto 1000 m, trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections as per Technical Specification Clause 302.3.5

740

-

-

... More
Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5

5037.27

-

-

... More
Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5

4174.31

-

-

... More
Construction of Shoulders as per Technical Specification Clause 407. B) Hard Murum Shoulder

911.28

-

-

... More
Pavement Works (GSB, WBM, Bituminous Works) and Cement Concrete Pavement Work

-

-

-

... More
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.(A) By Mix in Place Method (Grading II Material & 100% crushed aggregate)

663.65

-

-

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 2 as per Technical Specification Clause 405. crushable screening For - By Mechanical Means (100% crushed aggregate)

169.78

-

-

... More
Construction of modified penetration macadam 50mm thick over prepared base by providing a layer of compacted crushed coarse aggregate using chips spreader with alternate applications of bituminous binder of VG-30 Grade @1.75kg/sq.meter and key aggregates and rolling with a three wheel 80-100 kN static roller to achieve the desired degree of compaction as per Technical Specification Clause 506.(VG-30 bulk bitumen rates are considered to arrive at rates)

34.38

-

-

... More
Providing and laying White Topping/Short Paneled Concrete as per IRC-SP 76-2015 (Existing surface preparation to be done if necessary either by milling or leveling course with DLC to correct surface profile and to be paid separately) with un reinforced M-40 grade Pavement Quality Concrete using Ordinary Portland Cement 43/53 Grade OR Portland Pozzolona Cement IS-1489 at 425kg/cum, coarse aggregate, fine aggregate(VSI) and Admixture confirming to IS 9130-1999 (R-2004) polymeric synthetic fiber as per ASTM (1116) such as polyester / polyethylene / polypropylene / Glass fiber at 1.20 kg/cum, mixed in batching and mixing plant or weigh batcher as per approved mix design to achieve minimum flexural strength or modulus of rupture of concrete 4.50 MPa at 28 days limiting maximum water cement ratio to 0.40, transported to site, laid with fixed form/ slip form paver finisher (preferably with slip form paver finisher), spread, vibrated, compacted and finished in a continuous operation to the lines and grades as per drawing, texture finishing of surface, spraying two layers of curing compound, curing with water sprayed on hessian cloth covered over concrete surface, groove cutting grid 1m x 1m or as directed by Engineer Incharge to a depth of 1/3 to 1/4 of the Thickness and of width 3-5 mm as per design including cost of all material, side form work, labour and machineries etc. complete as per specifications.(Excluding Dowel Bars and Tie Bars)(Crushed VSI Sand) Including Polythene Sheet of 125 Micron

2153.7

-

-

... More
Construction of dry lean cement concrete Sub-base over a prepared sub-grade with coarse and fine aggregate conforming to 15: 383, the size of coarse aggregate not exceeding 25 mm., cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor /by suitable means as approved by Engineer-in-charge, compacting with vibratory roller, finishing, curing and including preparation of sub-grade surface if required etc. complete.

1680.22

-

-

... More
Providing and fixing in position 25mm dia anti corossive MS dowel bars of required Dia. 60 cms. Long and at 30.00 cm. C/C and wherever directed including handling, straightening, necessary cutting supported by chairs with proper alignment with half length covered by polythene sheathing including cap etc. complete.

230

-

-

... More
Providing and fixing in position anti corrossive TMT FE 500, tie bars of 12 mm dia. 70 cms. long and at 30.00 cm. C/C and wherever directed including handling, straightening, necessary cutting, handling, straightening , supported by assembly of TMT FE 500, chairs with proper alignment etc. complete.

12667

-

-

... More
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared dry and hungry bituminous surface cleaned with Hydraulic broom as per Technical Specification MORD 2014Clause 503.

34.38

-

-

... More
Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. For -Case - II By Mechanical Means Bitumen (S-65) VG-30

34.38

-

-

... More
Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510. Case - I : Type A Bitumen (S-65) VG-30 by Mechanical Means (emulsion SS 2)

34.38

-

-

... More
Cross Drainage Structures (Culverts & Minor Bridges), Drains and Protection Works

-

-

-

... More
Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal with all lift and lead, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary soil

196.61

-

-

... More
Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal with all lift and lead, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary rock (not requiring blasting) Upto 3 m depth

54.7

-

-

... More
Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal with all lift and lead, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Hard rock (requiring blasting) Upto 3 m depth including 1.5 m depth in hard rock

27.7

-

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 -P.C.C M-10(Crushed Sand)

54.08

-

-

... More
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 - P.C.C grade M 15 Nominal mix(1:2.5:5) (Crushed Sand)

259.81

-

-

... More
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 - R.C.C grade M 20 (Crushed sand )

3.9

-

-

... More
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications MORD 2014 Clauses 800, 1205.4 and 1205.5 R.C.C grade M 25 (Crushed sand )

8.78

-

-

... More
Providing and laying cement concrete wearing course M 30 grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3 (Crushed sand )

1.89

-

-

... More
TMT BAR Reinforcement Supplying, fitting, and placing TMT bar reinforcement in Superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202

1.14

-

-

... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7. A.C. pipe 100 mm Dia

26

-

-

... More
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. B. 1000 mm HP Drain NP3 Class As per Technical Specification MORD 2014 Cluase No. 1100

40

-

-

... More
Lowering, laying and jointing in proper grade and alignment R.C.C. pipes with collar joints in C.M.1:1 proportion or socketed R.C.C. pipes with rubber joints (excluding cost of rubber ring or R.C.C. collar,) including cost of conveyance from stores to site of work, cost of jointing material, labour, etc. complete as directed by Engineerin- charge (For all class of pipes.) as per IS- 783-1985.

180

-

-

... More
Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 1000mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete

25

-

-

... More
Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 600mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.

85

-

-

... More
Providing ISI standard R.C.C. pipes in standard lengths of following class and diameter suitable for either collar joints or rubber ring joints, excluding GST lev-ied by GOI & GOM in all respect including inspec- tion charges, transport to departmental stores, unloading and stacking etc. complete as per IS-458/1988. 300 mm NP3

180

-

-

... More
Providing Tar paper bearing of approved quality in proper size etc. complete (Rate as per PWD a CSR Nagpur for 2015-16) As per Technical Specification MORD 2014 Cluase No. 1402.

10.5

-

-

... More
Providing and fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing and technical specificationss(250mm deep)

15

-

-

... More
Providing 0.90 meter thick metal mat of rubble oversize metal for specified thickness a per detailed drawing including supplying all materials hand packing rubble spreading metal and hard murum including watering and compaction with power roller etc. complete. Spec. No.: As directed by Engineer in charge

33

-

-

... More
Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surfaces as per drawing and Technical Specification Clause 1701

5.14

-

-

... More
Printing new letters and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade as per drawings and Technical Specification Clause 1701

480

-

-

... More
Maintenance of Hume pipe Culvert by way of Clearing, Cleaning, Erosion repair, repairs to cracks, parapet wall and protection work as per drawing and technical specification Clause 1908

9

-

-

... More
Traffic Signs, Markings and Road Appurtenances, Road Safety & Road Furniture

-

-

-

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014 Clause 1703 Ordinary Kilometer Stone (Precast)

4

-

-

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014 Clause 1703 200 m stone (precast)

15

-

-

... More
Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704

393

-

-

... More
Providing and fixing trap /granite/ quartzite/ gneiss/ guard stone/ indicator stones/ boundry stones of standard size & shape including fixing In ground and washing complete Spec. No.: MORTH 807

12.77

-

-

... More
Providing and fixing of typical PMGSY Retro Reflective information board as per as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing.Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottom duly rivetted with MS angles of 35 x 35 x 5 mm thick M.S angle shall be welded by two vertical M.S angle of 5 mm thick to 75 mm x 75 mm of 12 SWG square tubes / 75mm Dia Pipe posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 75mm, below ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2022. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 7 years for Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4 and as directed by Engineer-In-charge. . A warranty for 7 years for the Retro reflective sheeting for Class-B respectively, from original manufacturer shall be submitted by contractor.

2

-

-

... More
Providing and fixing Retro Reflective MMGSY / PMGSY LOGO informatory sign board with Logo as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circular and drawing. The board will be a composite unit consisting of Two Plates of ACP (Aluminum Composite Panel), material specifications as per clause 17001.3. The top most plate will be of 3 mm ACP in diamond shape of 600x600mm size, riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. The Lower plate will be of 4mm ACP of 1100x300mm size riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. Riveting of all the sheets over angle and flat iron frame will be done neatly to have plain surface on one side. The angle iron frame of Both the plates will be welded to a 75mm x75mmx 12swg Mild steel post at / Tube Centre and this post will be embeded in cement concrete M15 grade block of 450x450x600mm below ground level. The height of the bottom of the lower plate will be 1200mm from normal ground level. The spacing between the diamond shaped plate and Lower Plate is kept 150mm. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2022. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 7 years for Class B sheeting respectively for traffic colors.”All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY signage manual Fig.1 (A) and Fig.1 (B) and as directed by Engineer in-charge. A warranty for 7 years for the Retro reflective sheeting for Class-B respectively, from original manufacturer shall be submitted by contractor.

2

-

-

... More
Providing and erecting direction and place identification retro-\reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on mild steel angle iron posts 75 mm x 75 mm x 6 mm, 2 Nos. firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701

2.16

-

-

... More
Providing and fixing of typical MMGSY / PMGSY Retro Reflective information board as per section 1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing.The ACP sheets of 3 mm thick, of 1500mmx900 mm size duly rivetted with MS angles of 25 x 25 x 5 mm thick M.S angle. Riveting of all the sheets over angle and flat iron frame will be done neatly to have plain surface on one side. The angle iron frame of the plate will be welded to two nos. 75mm x75mm (12 SWG) sheet tubes posts placed at 1125mm apart centre to centre. These two posts will be embeded in cement concrete M15 grade block of 600x600x750mm below ground level. The height of the bottom of the plate will be 775mm from normal ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2022. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 7 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 7 years for Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-B grade as per the latest MORD section 1700 specifications. All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.5 and as directed by Engineer-In-charge. . A warranty for 7 years for the Retro reflective sheeting for Class-B respectively, from original manufacturer shall be submitted by contractor.

1

-

-

... More
Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area not exceeding 0.9 sqm supported on a mild steel single angle iron post 75 x 75 x 6 mm firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 x 450 x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701. Retro-reflectorised Traffic Signs

12.54

-

-

... More
Road Delineators: Supplying and installation of delineators (Roadway Indicators, Hazard markers, Object markers) 80 to 100 cm high above ground level, painted black and white in 15 cm wide strips, fitted with 80x100mm rectangular or 75mm dia. Circular reflectorised panels at the top, buried or pressed into the ground and confirming to I.R.C. 79 and the drawings.

66

-

-

... More
Providing and fixing of road stud 100 x 100 mm die cast in aluminium, resistant to corrosive effect of salt and grit, fitted with lense reflectors, installed in concrete or asphaltic surface by drilling holes 30 mm upto a depth of 600 mm and bedded in a suitable bituminous grout or epoxy mortar, all as per BS:873 (Part 4) 1973.

36

-

-

... More
Providing and Laying hot applied thermoplastic road marking strip on Bituminous Surface of specified shade/ colour of 2.5 mm thick including 1.5 Refractive index reflectorizing glass beads @ 250gm/sqm .Thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC 35:2015. Initial Dry reflectivity RL shall be 250 mcd/sqm/lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/sqm/ lux and Qd of 100 mcd/sqm/ lux measured at the end of 2 years by means of a Standard Reflectometer of Zehntner, Easylux, Delta make capable of measuring RL & QD both according to IRC 35:2015 clause 15.5. The finished surface to be level, uniform, and free from streaks and holes complete as per direction of Engineer-in-charge and in accordance with applicable specifications.(Refer MORTH Clause 803 for technical Specification and Performance for IRC 35:2015).

41.4

-

-

... More
Improvement & 10 Year Maintenance of Khede To Ranwad Road (KM 0/000 - 4/770) (TR-22,VR-83), Block-Niphad, District-Nashik

-

-

-

... More
Site Clearance, Dismantling and Earth Works

-

-

-

... More
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. (A) In area of Non - thorny jungle

2.86

-

-

... More
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. (B) In area of thorny jungle

0.72

-

-

... More
Scarifying the existing bituminous road surface to a depth of 150 mm and disposal of scarified material with a lift upto 3 m and lead upto 1000 m as per Technical Specification Clause 301.4.

12450

-

-

... More
Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross - sections, and transporting to the embankment location with a lift up to 1.5 m and lead Above 1000 m as per Technical Specification Clause 302.3

8736.4

-

-

... More
Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, transporting to embankment site with a lift upto 1.5 m and lead upto 1000 m, trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections as per Technical Specification Clause 302.3.5

1669.2

-

-

... More
Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5

6466.48

-

-

... More
Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5

5631.17

-

-

... More
Construction of Shoulders as per Technical Specification Clause 407. B) Hard Murum Shoulder

1140

-

-

... More
Pavement Works (GSB, WBM, Bituminous Works) and Cement Concrete Pavement Work

-

-

-

... More
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.(A) By Mix in Place Method (Grading II Material & 100% crushed aggregate)

983.42

-

-

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 2 as per Technical Specification Clause 405. crushable screening For - By Mechanical Means (100% crushed aggregate)

536.42

-

-

... More
Construction of modified penetration macadam 50mm thick over prepared base by providing a layer of compacted crushed coarse aggregate using chips spreader with alternate applications of bituminous binder of VG-30 Grade @1.75kg/sq.meter and key aggregates and rolling with a three wheel 80-100 kN static roller to achieve the desired degree of compaction as per Technical Specification Clause 506.(VG-30 bulk bitumen rates are considered to arrive at rates)

34.38

-

-

... More
Providing and laying White Topping/Short Paneled Concrete as per IRC-SP 76-2015 (Existing surface preparation to be done if necessary either by milling or leveling course with DLC to correct surface profile and to be paid separately) with un reinforced M-40 grade Pavement Quality Concrete using Ordinary Portland Cement 43/53 Grade OR Portland Pozzolona Cement IS-1489 at 425kg/cum, coarse aggregate, fine aggregate(VSI) and Admixture confirming to IS 9130-1999 (R-2004) polymeric synthetic fiber as per ASTM (1116) such as polyester / polyethylene / polypropylene / Glass fiber at 1.20 kg/cum, mixed in batching and mixing plant or weigh batcher as per approved mix design to achieve minimum flexural strength or modulus of rupture of concrete 4.50 MPa at 28 days limiting maximum water cement ratio to 0.40, transported to site, laid with fixed form/ slip form paver finisher (preferably with slip form paver finisher), spread, vibrated, compacted and finished in a continuous operation to the lines and grades as per drawing, texture finishing of surface, spraying two layers of curing compound, curing with water sprayed on hessian cloth covered over concrete surface, groove cutting grid 1m x 1m or as directed by Engineer Incharge to a depth of 1/3 to 1/4 of the Thickness and of width 3-5 mm as per design including cost of all material, side form work, labour and machineries etc. complete as per specifications.(Excluding Dowel Bars and Tie Bars)(Crushed VSI Sand) Including Polythene Sheet of 125 Micron

2715.62

-

-

... More
Construction of dry lean cement concrete Sub-base over a prepared sub-grade with coarse and fine aggregate conforming to 15: 383, the size of coarse aggregate not exceeding 25 mm., cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor /by suitable means as approved by Engineer-in-charge, compacting with vibratory roller, finishing, curing and including preparation of sub-grade surface if required etc. complete.

2193.62

-

-

... More
Providing and fixing in position 25mm dia anti corossive MS dowel bars of required Dia. 60 cms. Long and at 30.00 cm. C/C and wherever directed including handling, straightening, necessary cutting supported by chairs with proper alignment with half length covered by polythene sheathing including cap etc. complete.

288

-

-

... More
Providing and fixing in position anti corrossive TMT FE 500, tie bars of 12 mm dia. 70 cms. long and at 30.00 cm. C/C and wherever directed including handling, straightening, necessary cutting, handling, straightening , supported by assembly of TMT FE 500, chairs with proper alignment etc. complete.

15900

-

-

... More
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared dry and hungry bituminous surface cleaned with Hydraulic broom as per Technical Specification MORD 2014Clause 503.

34.38

-

-

... More
Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. For -Case - II By Mechanical Means Bitumen (S-65) VG-30

34.38

-

-

... More
Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510. Case - I : Type A Bitumen (S-65) VG-30 by Mechanical Means (emulsion SS 2)

34.38

-

-

... More
Cross Drainage Structures (Culverts & Minor Bridges), Drains and Protection Works

-

-

-

... More
Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal with all lift and lead, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary soil

404.32

-

-

... More
Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal with all lift and lead, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary rock (not requiring blasting) Upto 3 m depth

132.02

-

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 -P.C.C M-10(Crushed Sand)

122.13

-

-

... More
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 - P.C.C grade M 15 Nominal mix(1:2.5:5) (Crushed Sand)

652.17

-

-

... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7. A.C. pipe 100 mm Dia

95

-

-

... More
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. B. 1000 mm HP Drain NP3 Class As per Technical Specification MORD 2014 Cluase No. 1100

87.5

-

-

... More
Lowering, laying and jointing in proper grade and alignment R.C.C. pipes with collar joints in C.M.1:1 proportion or socketed R.C.C. pipes with rubber joints (excluding cost of rubber ring or R.C.C. collar,) including cost of conveyance from stores to site of work, cost of jointing material, labour, etc. complete as directed by Engineerin- charge (For all class of pipes.) as per IS- 783-1985.

50

-

-

... More
Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 1000mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete

20

-

-

... More
Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 600mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.

55

-

-

... More
Providing ISI standard R.C.C. pipes in standard lengths of following class and diameter suitable for either collar joints or rubber ring joints, excluding GST lev-ied by GOI & GOM in all respect including inspec- tion charges, transport to departmental stores, unloading and stacking etc. complete as per IS-458/1988. 300 mm NP3

50

-

-

... More
Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surfaces as per drawing and Technical Specification Clause 1701

9

-

-

... More
Printing new letters and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade as per drawings and Technical Specification Clause 1701

800

-

-

... More
Maintenance of Causeway by way of minor Surface repairs, replacing Guide Posts, repair of flood gauges, removal of debris, providing boulders and protection work and painting as per technical specification Clause 1909

21

-

-

... More
Traffic Signs, Markings and Road Appurtenances, Road Safety & Road Furniture

-

-

-

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014 Clause 1703 Ordinary Kilometer Stone (Precast)

5

-

-

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014 Clause 1703 200 m stone (precast)

19

-

-

... More
Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704

288

-

-

... More
Providing and fixing of typical PMGSY Retro Reflective information board as per as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing.Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottom duly rivetted with MS angles of 35 x 35 x 5 mm thick M.S angle shall be welded by two vertical M.S angle of 5 mm thick to 75 mm x 75 mm of 12 SWG square tubes / 75mm Dia Pipe posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 75mm, below ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2022. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 7 years for Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4 and as directed by Engineer-In-charge. . A warranty for 7 years for the Retro reflective sheeting for Class-B respectively, from original manufacturer shall be submitted by contractor.

2

-

-

... More
Providing and fixing Retro Reflective MMGSY / PMGSY LOGO informatory sign board with Logo as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circular and drawing. The board will be a composite unit consisting of Two Plates of ACP (Aluminum Composite Panel), material specifications as per clause 17001.3. The top most plate will be of 3 mm ACP in diamond shape of 600x600mm size, riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. The Lower plate will be of 4mm ACP of 1100x300mm size riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. Riveting of all the sheets over angle and flat iron frame will be done neatly to have plain surface on one side. The angle iron frame of Both the plates will be welded to a 75mm x75mmx 12swg Mild steel post at / Tube Centre and this post will be embeded in cement concrete M15 grade block of 450x450x600mm below ground level. The height of the bottom of the lower plate will be 1200mm from normal ground level. The spacing between the diamond shaped plate and Lower Plate is kept 150mm. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2022. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 7 years for Class B sheeting respectively for traffic colors.”All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY signage manual Fig.1 (A) and Fig.1 (B) and as directed by Engineer in-charge. A warranty for 7 years for the Retro reflective sheeting for Class-B respectively, from original manufacturer shall be submitted by contractor.

2

-

-

... More
Providing and erecting direction and place identification retro-\reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on mild steel angle iron posts 75 mm x 75 mm x 6 mm, 2 Nos. firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701

2.16

-

-

... More
Providing and fixing of typical MMGSY / PMGSY Retro Reflective information board as per section 1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing.The ACP sheets of 3 mm thick, of 1500mmx900 mm size duly rivetted with MS angles of 25 x 25 x 5 mm thick M.S angle. Riveting of all the sheets over angle and flat iron frame will be done neatly to have plain surface on one side. The angle iron frame of the plate will be welded to two nos. 75mm x75mm (12 SWG) sheet tubes posts placed at 1125mm apart centre to centre. These two posts will be embeded in cement concrete M15 grade block of 600x600x750mm below ground level. The height of the bottom of the plate will be 775mm from normal ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2022. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 7 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 7 years for Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-B grade as per the latest MORD section 1700 specifications. All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.5 and as directed by Engineer-In-charge. . A warranty for 7 years for the Retro reflective sheeting for Class-B respectively, from original manufacturer shall be submitted by contractor.

1

-

-

... More
Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area not exceeding 0.9 sqm supported on a mild steel single angle iron post 75 x 75 x 6 mm firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 x 450 x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701. Retro-reflectorised Traffic Signs

18.71

-

-

... More
Road Delineators: Supplying and installation of delineators (Roadway Indicators, Hazard markers, Object markers) 80 to 100 cm high above ground level, painted black and white in 15 cm wide strips, fitted with 80x100mm rectangular or 75mm dia. Circular reflectorised panels at the top, buried or pressed into the ground and confirming to I.R.C. 79 and the drawings.

64

-

-

... More
Providing and fixing of road stud 100 x 100 mm die cast in aluminium, resistant to corrosive effect of salt and grit, fitted with lense reflectors, installed in concrete or asphaltic surface by drilling holes 30 mm upto a depth of 600 mm and bedded in a suitable bituminous grout or epoxy mortar, all as per BS:873 (Part 4) 1973.

130

-

-

... More
Providing and Laying hot applied thermoplastic road marking strip on Bituminous Surface of specified shade/ colour of 2.5 mm thick including 1.5 Refractive index reflectorizing glass beads @ 250gm/sqm .Thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC 35:2015. Initial Dry reflectivity RL shall be 250 mcd/sqm/lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/sqm/ lux and Qd of 100 mcd/sqm/ lux measured at the end of 2 years by means of a Standard Reflectometer of Zehntner, Easylux, Delta make capable of measuring RL & QD both according to IRC 35:2015 clause 15.5. The finished surface to be level, uniform, and free from streaks and holes complete as per direction of Engineer-in-charge and in accordance with applicable specifications.(Refer MORTH Clause 803 for technical Specification and Performance for IRC 35:2015).

56

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.