Pradhan Mantri Gram Sadak Yojana Tender
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Pradhan Mantri Gram Sadak Yojana - PMGSY Tender
Civil And Construction
Road Construction
Eprocure
Opening Date5 Feb 2024
Closing DateCancelled
Tender Amount₹ 92,51,158
Costs
EMD
₹ 72,000Document Cost
₹ 5,900Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_CEMAH_131811_2Tender No
TENDER Notice No.07/SR-2023-24Tender Authority
Pradhan Mantri Gram Sadak Yojana ViewPurchaser Address
-Website
http://http://omms.nic.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Maintenance of Slab Type culvert by way of clearing, cleaning, Erosion repair, repairs to cracks, parapet wall and protection work as per drawing and technical specification clause 1908.
8
34760
4345.07
... More
Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Mord 2014 Clause 301.5
999
80089
80.17
... More
Repairs to Pot holes by modified penetration macadam over prepared base by providing a layer of compacted crushed coarse aggregate using chips spreader with alternate applications of bituminous binder and key aggregates including excavating the sunken portions of failed road removal of failed materials, trimming the sides to vertical and leveling the bottom clearing the same with compressed air or any other appropriate method and rolling with a three wheel 80-100 kN static roller to achieve the desired degree of compaction with Bitumen (S-65) 60/70 - VG-30 as per Technical Specification Clause 506.
60
14480
241.34
... More
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.20 to 0.25 kg per sqm on the prepared dry and hungry bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503.
6000
73020
12.17
... More
Providing and constructing 50 mm. thick Modified Penetration Macadam (MPM) road surface including all mataerials, preparing the existing road surface, spreading 40mm. stone metal layers 100% crusher broken metal with conical crusher plant heating and spraying the bitumen of specified grade @ 1.75 kg/sqm, spreading 12mm.size chips compacting with static roller having weight 8 to 10 MT. to achive the desired degree of compaction as per Technical Specification Clause 506 etc. complete. Including picking of existing WBM surface.(VG-30 bulk bitumen rates are considered to arrive at rates) Bitumen (S-65) 60/70 - VG-30
4875
1173071
240.63
... More
Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. Case - II By Mechanical Means (II) Bitumen (S-65) VG-30 using Waste Plastic
6000
1084800
180.8
... More
Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A as per Technical Specification Clause 510 Case - I : Type A Bitumen (S-65) VG-30 By Mechanical means
6000
511560
85.26
... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014 Clause 1703 Ordinary Kilometer Stone (Precast)
4
11234
2808.69
... More
Semi Reflective Traffic Signs - Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type IV standards of ASTM D4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved , supported on a mild steel angle iron post 65 mm X 65 mm X 6 mm - 3.5 mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level as per approved drawing. Both border & background shall be retro reflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor(Bottom of the board shall be at least 2.6 mtr. above ground level) Specification: IRC 67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting.
600 x 450 mm Rectangular
4
18898
4724.5
... More
Direction and Place Identification signs upto 0.9 sqm size board
B. Semi-Reflective Traffic signs
Direction and place identification signs up to 0.9 sqm size board Providing and Fixing of Retro Reflectorised direction & place identification sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type IV standards of ASTM D4956-09 specifications, fixed over 4 mm thick ACP sheet supported with Back support frame of 35x35x5mm mild steel angle with areas not exceeding 0.9 sqm. Supported in mild steel angle iron post 75x75x6mm - 3.5 mtr height ,firmly fixed to the ground by means of properly designed foundation of M 20 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level complete (as per MoRT&H specification No.801) (for area Less than 0.9 sqm). 7Both border & background shall be retro reflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the Contractor(Bottom of the board shall be at least 2.6 mtr. above ground level) Specification: IRC 67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting.
2.09
20020
9584.6
... More
Name of Work _ 2) Special Repairs to Kharvad To Ghugarmalpada Road in Tal. Akrani & Dist. Nandurbar. (Section From Km 0/000 to 5/200 )
-
-
-
... More
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. (a) In area of thorny jungle
1.56
62834
40278.33
... More
Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and crofm-sections, and transporting to the embankment location with a lift upto 1.5 m and with all leads as per Technical Specification Clause 302.3
3182.4
197977
62.21
... More
Maintenance of Slab Type culvert by way of clearing, cleaning, Erosion repair, repairs to cracks, parapet wall and protection work as per drawing and technical specification clause 1908.
6
26070
4345.07
... More
Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Mord 2014 Clause 301.5
1170
93798
80.17
... More
Repairs to Pot holes by modified penetration macadam over prepared base by providing a layer of compacted crushed coarse aggregate using chips spreader with alternate applications of bituminous binder and key aggregates including excavating the sunken portions of failed road removal of failed materials, trimming the sides to vertical and leveling the bottom clearing the same with compressed air or any other appropriate method and rolling with a three wheel 80-100 kN static roller to achieve the desired degree of compaction with Bitumen (S-65) 60/70 - VG-30 as per Technical Specification Clause 506.
225
53667
238.52
... More
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.20 to 0.25 kg per sqm on the prepared dry and hungry bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503.
9300
112995
12.15
... More
Providing and constructing 50 mm. thick Modified Penetration Macadam (MPM) road surface including all mataerials, preparing the existing road surface, spreading 40mm. stone metal layers 100% crusher broken metal with conical crusher plant heating and spraying the bitumen of specified grade @ 1.75 kg/sqm, spreading 12mm.size chips compacting with static roller having weight 8 to 10 MT. to achive the desired degree of compaction as per Technical Specification Clause 506 etc. complete. Including picking of existing WBM surface.(VG-30 bulk bitumen rates are considered to arrive at rates) Bitumen (S-65) 60/70 - VG-30
2550
606415
237.81
... More
Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. Case - II By Mechanical Means (II) Bitumen (S-65) VG-30 using Waste Plastic
9300
1643217
176.69
... More
Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A as per Technical Specification Clause 510 Case - I : Type A Bitumen (S-65) VG-30 By Mechanical means
9300
779898
83.86
... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014 Clause 1703 Ordinary Kilometer Stone (Precast)
5
14043
2808.69
... More
Semi Reflective Traffic Signs - Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type IV standards of ASTM D4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved , supported on a mild steel angle iron post 65 mm X 65 mm X 6 mm - 3.5 mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level as per approved drawing. Both border & background shall be retro reflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor(Bottom of the board shall be at least 2.6 mtr. above ground level) Specification: IRC 67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting.
600 x 450 mm Rectangular
4
19087
4771.75
... More
Direction and place identification signs up to 0.9 sqm size board - Providing and Fixing of Retro Reflectorised direction & place identification sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type IV standards of ASTM D4956-09 specifications, fixed over 4 mm thick ACP sheet supported with Back support frame of 35x35x5mm mild steel angle with areas not exceeding 0.9 sqm. Supported in mild steel angle iron post 75x75x6mm - 3.5 mtr height ,firmly fixed to the ground by means of properly designed foundation of M 20 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level complete (as per MoRT&H specification No.801) (for area Less than 0.9 sqm). 7Both border & background shall be retro reflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor(Bottom of the board shall be at least 2.6 mtr. above ground level) Specification: IRC 67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting.
2.09
20020
9584.6
... More
Name of Work: 3) Special Repairs & 5 Year Maintenance to Khamla , Baripada To Akranimahal Road in Tal. Akrani & Dist. Nandurbar. (Section From Km 0/000 to 8/100 )
-
-
-
... More
Maintenance of Slab Type culvert by way of clearing, cleaning, Erosion repair, repairs to cracks, parapet wall and protection work as per drawing and technical specification clause 1908.
7
30415
4345.07
... More
Direction and Place Identification signs upto 0.9 sqm size board
B. Semi-Reflective Traffic signs
Direction and place identification signs up to 0.9 sqm size board Providing and Fixing of Retro Reflectorised direction & place identification sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type IV standards of ASTM D4956-09 specifications, fixed over 4 mm thick ACP sheet supported with Back support frame of 35x35x5mm mild steel angle with areas not exceeding 0.9 sqm. Supported in mild steel angle iron post 75x75x6mm - 3.5 mtr height ,firmly fixed to the ground by means of properly designed foundation of M 20 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level complete (as per MoRT&H specification No.801) (for area Less than 0.9 sqm). 7Both border & background shall be retro reflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the Contractor(Bottom of the board shall be at least 2.6 mtr. above ground level) Specification: IRC 67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting.
2.09
20020
9584.6
... More
Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary soil up to 3 m depth
84.28
49844
591.42
... More
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary rock (not requiring blasting) Upto 3 m depth
67.42
49842
739.28
... More
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Hard rock (requiring blasting) Upto 3 m depth including 1.5 m depth in hard rock
101.14
115884
1145.78
... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 II. P.C.C grade M 15 (i) Nominal mix (1:2.5:5)
50.57
333442
6593.68
... More
Providing concrete for plain/reinforced concrete in substructure complete as per drawings and technical specifications Clause 802, 804, 805, 806, 807, 1202 & 1204 I. P.C.C grade M 15 (i) Nominal mix (1:2.5:5)
244.16
1721269
7049.76
... More
Supplying, fitting and placing TMT bar reinforcement (Fe 415) in substructure complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
0.24
16544
69345.62
... More
Providing weepholes in brick masonry / stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification MORD 2014 Clauses 614, 709, 1204.3.7 A.C. pipe 100 mm Dia
280
56389
201.39
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements