Pradhan Mantri Gram Sadak Yojana Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Pradhan Mantri Gram Sadak Yojana - PMGSY Tender

Works
Civil And Construction
Road Construction
Eprocure
Opening Date29 Nov 2024
Closing Soon23 Dec 2024
Tender AmountRefer Documents 
Notes
Download

Costs

  • EMD

    ₹ 13,79,000
  • Document Cost

    ₹ 29,500
  • Tender Fee

    ₹ 500

Summary

Igatpuri Block 9 Road Works

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Clearing and Grubbing Road Land Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means In area of thorny jungle Technical Specification MoRD 2014 Clause 201.

0.57

-

-

... More
Excavation in Soil using Hydraulic Excavator and Tippers with disposal More than 100 m Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with a lift upto 1.5 m and lead More than 100 m Excavation in Soil using Hydraulic Excavator and Tippers with disposal More than 100 m Technical Specification MoRD 2014 Clause 302.3.

3080.78

-

-

... More
Excavation in Ordinary Rock using Hydraulic Excavator and Tippers with disposal More than 100 m Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, transporting to embankment site with a lift upto 1.5 m and lead More than 100 m, trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections. Technical Specification MoRD 2014 Clause 302.3.5

362.45

-

-

... More
Excavation in Hard Rock (requiring blasting) with disposal More than 100 m Excavation for roadway in hard rock (requiring blasting) by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross-sections, loading and disposal of cut rock with a lift upto 1.5 m and leads More than 100 m. Technical Specification MoRD 2014 Clause 302.3.5

181.22

-

-

... More
Construction of Embankment with Material Obtained from Roadway Cutting Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2. Technical Specification MoRD 2014 Tables 300.1 and 300.2 Clause 301.5.

2238.1

-

-

... More
Construction of Embankment with Material Obtained from Borrow Pits Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2. For lead upto 250 m Technical Specification MoRD 2014 Tables 300.1 and 300.2 Clause 301.5.

7434.13

-

-

... More
Scarifying Existing Surface to a Depth of 150 mm by Mechanical Means Scarifying the existing road surface to a depth of 150 mm and Sectioning for required width, watering and compaction of Scarified material with roller including all leads and lifts as per Technical Specification Clause 301.4., 303.5.2.

6750

-

-

... More
Dismantling Stone Masonry. Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m. Rubble Stone Masonry in Cement Mortar Technical Specification MoRD 2014 Clause 202.

33.33

-

-

... More
Removing all types of Hume pipes and stacking within a lead of 1000 m including Earthwork and Dismantling of Masonry Works. Above 600 mm to 900 mm dia Hume pipe Technical Specification MoRD 2014 Clause 202.

22.5

-

-

... More
Pavement Works (GSB, WBM, Bituminous Works) and Cement Concrete Pavement Work

-

-

-

... More
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per Technical Specification Clause 401. By Using Crushed Aggregate.

2121.07

-

-

... More
Water Bound Macadam with Crushable Screenings WBM Grading 2 Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 2. By Manual Means Technical Specification MoRD 2014 Clause 405.

2104.58

-

-

... More
Construction of Subgrade and Earthen Shoulders. Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification MORD 2014, Clause 303.1.

1482

-

-

... More
Tack Coat Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared bituminous surface cleaned with Hydraulic broom. Technical Specification MoRD 2014 Clause 503

14030.5

-

-

... More
Modified Penetration Macadam Construction of penetration macadam over prepared base by providing a layer of compacted crushed coarse aggregate using chips spreader with alternate applications of bituminous binder and key aggregates and rolling with a three wheel 80-100 kN static roller to achieve the desired degree of compaction. 50 mm thick Bitumen (S-65) 60/70 - VG-30 Technical Specification MoRD 2004 Clause 506

14030.5

-

-

... More
20mm thick Open-Graded Premix Carpet using Bituminous (penetration grade/modified bitumen) Binder Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C. Case - II By Mechanical Means Bitumen (S-65) VG-30 using Waste Plastic Technical Specification MoRD 2014 Clause 506.

14030.5

-

-

... More
Seal Coat Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C By Mechanical Means Case - I : Type A Bitumen (S-65) VG-30 Technical Specification MoRD 2014 Clause 508.

14030.5

-

-

... More
Thin White Topping Providing and laying White Topping/Short Paneled Concrete as per IRC-SP 76-2015 (Existing surface preparation to be done if necessary either by milling or leveling course with DLC to correct surface profile and to be paid separately) with un reinforced M-40 grade Pavement Quality Concrete using Ordinary Portland Cement 43/53 Grade OR Portland Pozzolona Cement IS-1489 at 425kg/cum, coarse aggregate, fine aggregate(VSI) and Admixture confirming to IS 9130-1999 (R-2004) polymeric synthetic fiber as per ASTM (1116) such as polyester / polyethylene / polypropylene / Glass fiber at 1.20 kg/cum, mixed in batching and mixing plant or weigh batcher as per approved mix design to achieve minimum flexural strength or modulus of rupture of concrete 4.50 MPa at 28 days limiting maximum water cement ratio to 0.40, transported to site, laid with fixed form/ slip form paver finisher (preferably with slip form paver finisher), spread, vibrated, compacted and finished in a continuous operation to the lines and grades as per drawing, texture finishing of surface, spraying two layers of curing compound, curing with water sprayed on hessian cloth covered over concrete surface, groove cutting grid 1m x 1m or as directed by Engineer Incharge to a depth of 1/3 to 1/4 of the Thickness and of width 3-5 mm as per design including cost of all material, side form work, labour and machineries etc. complete as per specifications.(Excluding Dowel Bars and Tie Bars) (Crushed VSI Sand ) Including Polythene Sheet of 125 Micron.

70.31

-

-

... More
MS dowel Bars Providing and fixing in position 25mm dia anti corossive MS dowel Bars of requird Dia 60 cms. Long and at 30.00 cms C/C and Wherever derect include handing, straighting necessary cutting support by chairs with proper alignment with half length covert by polythin sheathing include cap etc.

208

-

-

... More
TMT FE 500 ,tie bars Providing and fixing in position anti corrossive TMT FE 500 ,tie bars of 12 mm dia 70 cms long and at 30.00cm C/C and Wherever directed inclueding handling neccesary cutting, handling support by assembly of TMT FE 500, chairs with proper alignment complete

417

-

-

... More
Cross Drainage Structures (Culverts & Minor Bridges), Drains and Protection Works

-

-

-

... More
Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary soil Upto 3 m depth By Mannual means As per MORD - 2014 Specification clause No. 305

255.66

-

-

... More
Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary rock (not requiring blasting) Upto 3 m depth As per MORD - 2014 Specification clause No. 305

128.22

-

-

... More
Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Hard rock (requiring Prohibeted) Upto 3 m depth including 1.5 m depth in hard rock As per MORD - 2014 Specification clause No. 305

10.73

-

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications as per MORD - 2014 Clause 802, 803, 1202 & 1203 P.C.C grade M 10 Nominal mix 1:3:6

42.74

-

-

... More
Providing and Laying Reinforced Cement Concrete Pipe NP3 as per design Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets As per MORD Specification 2014 Clause No. 1100. 1000 mm dia

67.5

-

-

... More
Providing and Laying Reinforced Cement Concrete Pipe NP2 as per design Providing and laying reinforced cement concrete pipe NP2 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets As per MORD Specification 2014 Clause No. 1100. 300 mm dia NP-2 Pipe

112.5

-

-

... More
Providing and Laying Reinforced Cement Concrete Pipe NP3 as per design Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets As per MORD Specification 2014 Clause No.1100. 600 mm dia NP-3 Pipe

55

-

-

... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification MORD 2014 Clauses 614, 709 P.V.C. pipe 100 mm dia

17

-

-

... More
Pitching on slopes Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1302

71.82

-

-

... More
P. C. C. grade M - 15 Concrete Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204

89.5

-

-

... More
P. C. C. grade M - 15 ConcretePlain / reinforced cement concrete grade M-15 (Nominal Mix (1:2.5:5)

283

-

-

... More
Traffic Signs, Markings and Road Appurtenances, Road Safety & Road Furniture

-

-

-

... More
Kilometre Stone Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014, Clause 1703 Kilometre Stone (precast)

4

-

-

... More
Kilometre Stone Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014, Clause 1703 200 m Stone

16

-

-

... More
Providing Guard stone/ boundary stone Providing and fixing trap /granite/ quartzite/ gneiss/ guard stone/ indicator stones/ boundry stones of standard size & shape including fixing In ground and white washing complete Spec. No.: As per MORTH Specification Clause No. 807

472

-

-

... More
Citizen Information Board Providing and fixing a typical MMGSY Citizen information board as per specification provided on detailed drawing of NRRDA having frame size of 2500 x 1150 mm with 75 mm square or round steel tube for support fixed in a concrete block of 60 x 60 x 75 cm size. Information as provided in drawing of NRRDA shall be displayed on a CR/GI sheet of appropriate thickness and fixed at steel frame with 5 mm steel plate. All lettering and painting arrows border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and coloured as mentioned in detailed drawing. All sections of framed posts and steel tube shall be painted with primer and two coat of epoxy paint as per drawings. Rate As per RD and WC Deptt. No. CMGSY - 2007 / CR / 145 / Yojana - 9 Dt. 04 / 04 / 2007

1

-

-

... More
Providing and Fixing 'Logo' of MMGSY Project Providing and fixing of typical MMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 as per MORD - 2014

1

-

-

... More
Direction and Place Identification signs upto 0.9 sqm size board B. Semi-Reflective Traffic signs Direction and place indentification signs up to 0.9 sqm size board Providing and erecting direction and place identifications of semi reflective sign boards as per IRC:67 made of 2 mm thick M.S. Sheet duly stove enameled paint in white colour in front and grey colour on back with red reflective border of 70 mm width and required message, letters, figures with reflective engineering grade tape as per MORD specifications of required shade and colour. Supported and welded on 47 mm x 47mm of 12 SWG Square tube of 3050 mm height duly strengthened by 25 mm x 5 mm M/s flat iron on edges on back firmly fixed to the ground by means of properly designed foundations with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701 As per MORD - 2014

25.92

-

-

... More
Providing and fixing of retro- reflectorised informatory sign board rectangular/Square in shape having area less than 0.9 One Square Meterr made out of ____mm aluminum sheet bonded with white retro reflective sheeting of Class __ ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3, supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with two coats of grey stove enamel paint and supported on one no. mild steel angle iron post 75 mm x 75 mm x 6 mm, 3.5 mt long firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing The angle iron post shall be duly painted with one coat of epoxy primer and two coats of epoxy finish paints having alternate black and white bands of 25 cm width including GI fixures and transportation etc.complete.The nut bolts of board with angle iron post/supporting structure after fixing at site has to be electrically welded. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) sheeting shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier.

32.4

-

-

... More
Providing white and colour washing to road side trees Providing white and colour washing to road side trees in 2 coats in 2 bands of white and one red band at centre of 30 cm height each including preparing the surface, cost of material, conveying etc. complete.

40

-

-

... More
Metal Beam Crash Barrier -- Type - A, W : Metal Beam Crash Barrier (Providing and erecting a W metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810)""

70

-

-

... More
Supplying and Fixing of Cat's Eye Supplying and Fixing of Molded Shank Raised Pavement Markers / Cat's Eye made of polycarbonate and ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face and shall support a load of 16000 kg tested in accordance to ASTM D 4280 Type H and complying to Specifications of Category A of MORTH Circular No RW/NH/33023/10-97 DO III Dt 11.06. 1997. The height, width and length shall not exceed 50 mm, 100 mm and 102 +/- 2 mm and with minimum reflective area of 13 Sqcm on each side and the slope to the base shall be 35 +/- 5 degree. The strength of detachment of the integrated cylindrical shanks, (of diameter not less than 19 +/- 2 mm and height not less than 30+/- 2 mm) from the body is to be a minimum value of 500 Kg. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturer's recommendation and complete as directed by the engineer.The contractor shall submit a two year warranty for satisfactory field performance including stipulated retro-reflectance of the reflecting panel, to the Engineer.

240

-

-

... More
Road Marking with Thermoplastic Compound Road Marking with Hot Applied Thermoplastic Compound with Reflectorizing Glass Beads on Bituminous Surface- Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorizing glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.complete.

182.2

-

-

... More
Providing Vertical Delineator having wide angle cube corner micro prismatic non metallic reflective sheeting confirming to Type XI of ASTM D4956 -09 with White Color and Red Color combination and having minimum of retro reflective exposed area of 125 Sq CM on top slots and 35 Sq CM on bottom slots and no edges shall be exposed for tampering. This tubular delineator shall have a core and shell construction, shell shall be made of tough, high impact resistant, injection-molded, thermoplastic outer body and the inner core shall consist of powder coated or painted Mild steel of minimum thickness 1.0mm.and core-shell structure shall be of height not less than 800 mm above the ground and width not less than 80 mm. The metallic core of the delineator shall extend 300mm beyond the shell length from bottom for installing in the ground. The extended portion shall have slots to insert anchoring rods for enhancing the concrete grip. The logo of the manufacturer shall be embossed on either side of the body in the injection molding process. The engineering thermoplastic used for making the delineator body shall have minimum initial mechanical properties of 600J/m tested in accordance with ASTM D256 and shall retain at least 70% of these minimum initial values when subjected to accelerated weathering for 1000hrs as per ASTM G155 or UL 746C and as per IRC 79 specifications and including fixing the unit in M20 Grade Cement Concrete of Size 30x30x40 cm including excavation for pit.

72

-

-

... More
Providing and fixing Cautionary/Warning sign boards in Equilateral Triangle size of 600 mm made out of 1.5mm aluminum sheet bonded with white retro reflective sheeting of Class C ( Type XI Micro prismatic grade sheeting) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3 Supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with grey stove enamel paint and supported on one no. of M. S. angle iron post of size 65 mm X 65 mm X 6 mm, 3.45 m long, duly painted with with flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in M25 grade concrete block of size 60cm X 60cm X 75cm including transportation etc; complete. ClassC ( Type XI Micro prismatic grade sheeting) shall have 10 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier.

20

-

-

... More
Providing and fixing Mandatory/Regulatory sign boards in circular shape of 600 mm dia made out of 3mm aluminum composite material ( ACM) sheet bonded with white retro reflective sheeting of Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3 Supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with grey stove enamel paint and supported on one no. of M. S. angle iron post of size 65 mm X 65 mm X 6 mm, 3.45 m long, duly painted with with flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in M25 grade concrete block of size 60cm X 60cm X 75cm including transportation etc; complete. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier.

32

-

-

... More
Providing & fixing Hazard markers board Providing & fixing Hazard markers board in rectangular shape of size 0.30x0.90m made out of 16 guage (1.60mm) thick M.S.sheet with angle frame 25X25X5 mm for pannel ,black non reflective opaque back ground and yellow oblique engineering grade reflective bands & back side in gray stove enamal paint etc complete ,including one MS.angle iron post of 50mmx50mmx6mm 1.8 mtr long painted with synthetick enamel paint of black colour including in G.I.fixture etc & fixing the board in 1:2.5:3 (M-15 Grade) concrete block of size 45cm x45cmx60cm .including transportation etc . complete

60

-

-

... More
MMGSY / PMGSY Maintenance Information Board Providing and fixing of typical MMGSY / PMGSY Retro Reflective information board as per section 1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing.The ACP sheets of 3 mm thick, of 1500mmx900 mm size duly rivetted with MS angles of 25 x 25 x 5 mm thick M.S angle. Riveting of all the sheets over angle and flat iron frame will be done neatly to have plain surface on one side. The angle iron frame of the plate will be welded to two nos. 75mm x75mm (12 SWG) sheet tubes posts placed at 1125mm apart centre to centre. These two posts will be embeded in cement concrete M15 grade block of 600x600x750mm below ground level. The height of the bottom of the plate will be 775mm from normal ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications. All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.5 and as directed by Engineer-In-charge. . A warranty for 5 / 7 years for the Retro reflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor.

1

-

-

... More
Improvement and 5 Years of Maintenance of Road from MDR-25 (Bobalewadi) Maydara to Shirewadi Road, (TR-06), (ODR-102), (VR-17), KM :- 0/000 to 3/500, Taluka - Igatpuri, District - Nashik.

-

-

-

... More
Site Clearance, Dismantling and Earth Works

-

-

-

... More
Clearing and Grubbing Road Land Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means In area of non-thorny jungle Technical Specification MoRD 2014 Clause 201.

0.53

-

-

... More
Clearing and Grubbing Road Land Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means In area of thorny jungle Technical Specification MoRD 2014 Clause 201.

0.53

-

-

... More
Excavation in Soil using Hydraulic Excavator and Tippers with disposal More than 100 m Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with a lift upto 1.5 m and lead More than 100 m Excavation in Soil using Hydraulic Excavator and Tippers with disposal More than 100 m Technical Specification MoRD 2014 Clause 302.3.

2312.21

-

-

... More
Excavation in Ordinary Rock using Hydraulic Excavator and Tippers with disposal More than 100 m Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, transporting to embankment site with a lift upto 1.5 m and lead More than 100 m, trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections. Technical Specification MoRD 2014 Clause 302.3.5

272.03

-

-

... More
Excavation in Hard Rock (requiring blasting) with disposal More than 100 m Excavation for roadway in hard rock (requiring blasting) by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross-sections, loading and disposal of cut rock with a lift upto 1.5 m and leads More than 100 m. Technical Specification MoRD 2014 Clause 302.3.5

136.01

-

-

... More
Construction of Embankment with Material Obtained from Roadway Cutting Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2. Technical Specification MoRD 2014 Tables 300.1 and 300.2 Clause 301.5.

1679.76

-

-

... More
Construction of Embankment with Material Obtained from Borrow Pits Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2. For lead upto 250 m Technical Specification MoRD 2014 Tables 300.1 and 300.2 Clause 301.5.

7779.84

-

-

... More
Pavement Works (GSB, WBM, Bituminous Works) and Cement Concrete Pavement Work

-

-

-

... More
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per Technical Specification Clause 401. By Using Crushed Aggregate.

67.74

-

-

... More
Water Bound Macadam with Crushable Screenings WBM Grading 2 Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 2. By Manual Means Technical Specification MoRD 2014 Clause 405.

1980.38

-

-

... More
Construction of Subgrade and Earthen Shoulders. Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification MORD 2014, Clause 303.1.

2089.5

-

-

... More
Tack Coat Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared bituminous surface cleaned with Hydraulic broom. Technical Specification MoRD 2014 Clause 503

13280

-

-

... More
Modified Penetration Macadam Construction of penetration macadam over prepared base by providing a layer of compacted crushed coarse aggregate using chips spreader with alternate applications of bituminous binder and key aggregates and rolling with a three wheel 80-100 kN static roller to achieve the desired degree of compaction. 50 mm thick Bitumen (S-65) 60/70 - VG-30 Technical Specification MoRD 2004 Clause 506

13280

-

-

... More
20mm thick Open-Graded Premix Carpet using Bituminous (penetration grade/modified bitumen) Binder Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C. Case - II By Mechanical Means Bitumen (S-65) VG-30 using Waste Plastic Technical Specification MoRD 2014 Clause 506.

13280

-

-

... More
Seal Coat Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C By Mechanical Means Case - I : Type A Bitumen (S-65) VG-30 Technical Specification MoRD 2014 Clause 508.

10655

-

-

... More
Cross Drainage Structures (Culverts & Minor Bridges), Drains and Protection Works

-

-

-

... More
Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary soil Upto 3 m depth By Mannual means As per MORD - 2014 Specification clause No. 305

205.33

-

-

... More
Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary rock (not requiring blasting) Upto 3 m depth As per MORD - 2014 Specification clause No. 305

108.38

-

-

... More
Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Hard rock (requiring Prohibeted) Upto 3 m depth including 1.5 m depth in hard rock As per MORD - 2014 Specification clause No. 305

10.73

-

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications as per MORD - 2014 Clause 802, 803, 1202 & 1203 P.C.C grade M 10 Nominal mix 1:3:6

34.46

-

-

... More
Providing and Laying Reinforced Cement Concrete Pipe NP3 as per design Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets As per MORD Specification 2014 Clause No. 1100. 1000 mm dia

55

-

-

... More
Providing and Laying Reinforced Cement Concrete Pipe NP2 as per design Providing and laying reinforced cement concrete pipe NP2 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets As per MORD Specification 2014 Clause No. 1100. 300 mm dia NP-2 Pipe

60

-

-

... More
Providing and Laying Reinforced Cement Concrete Pipe NP3 as per design Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets As per MORD Specification 2014 Clause No.1100. 600 mm dia NP-3 Pipe

71

-

-

... More
Painting Two Coats on New Concrete Surfaces Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surfaces as per drawing and Technical Specification MORD 2014 Clause 1701

0.9

-

-

... More
Printing New Letters and Figures of any Shade Printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade as per drawings and Technical Specification MORD 2014 Clause 1701 English and Roman Hyphens, commas and the like not to be measured and paid for. Detail for 100 letters of 160 mm height, i.e., 1600 cm

80

-

-

... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification MORD 2014 Clauses 614, 709 P.V.C. pipe 100 mm dia

17

-

-

... More
Pitching on slopes Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1302

56.7

-

-

... More
P. C. C. grade M - 15 Concrete Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204

89.5

-

-

... More
P. C. C. grade M - 15 ConcretePlain / reinforced cement concrete grade M-15 (Nominal Mix (1:2.5:5)

196.66

-

-

... More
Traffic Signs, Markings and Road Appurtenances, Road Safety & Road Furniture

-

-

-

... More
Kilometre Stone Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014, Clause 1703 Kilometre Stone (precast)

4

-

-

... More
Kilometre Stone Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014, Clause 1703 200 m Stone

14

-

-

... More
Providing Guard stone/ boundary stone Providing and fixing trap /granite/ quartzite/ gneiss/ guard stone/ indicator stones/ boundry stones of standard size & shape including fixing In ground and white washing complete Spec. No.: As per MORTH Specification Clause No. 807

435

-

-

... More
Citizen Information Board Providing and fixing a typical MMGSY Citizen information board as per specification provided on detailed drawing of NRRDA having frame size of 2500 x 1150 mm with 75 mm square or round steel tube for support fixed in a concrete block of 60 x 60 x 75 cm size. Information as provided in drawing of NRRDA shall be displayed on a CR/GI sheet of appropriate thickness and fixed at steel frame with 5 mm steel plate. All lettering and painting arrows border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and coloured as mentioned in detailed drawing. All sections of framed posts and steel tube shall be painted with primer and two coat of epoxy paint as per drawings. Rate As per RD and WC Deptt. No. CMGSY - 2007 / CR / 145 / Yojana - 9 Dt. 04 / 04 / 2007

1

-

-

... More
Providing and Fixing 'Logo' of MMGSY Project Providing and fixing of typical MMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 as per MORD - 2014

1

-

-

... More
Direction and Place Identification signs upto 0.9 sqm size board B. Semi-Reflective Traffic signs Direction and place indentification signs up to 0.9 sqm size board Providing and erecting direction and place identifications of semi reflective sign boards as per IRC:67 made of 2 mm thick M.S. Sheet duly stove enameled paint in white colour in front and grey colour on back with red reflective border of 70 mm width and required message, letters, figures with reflective engineering grade tape as per MORD specifications of required shade and colour. Supported and welded on 47 mm x 47mm of 12 SWG Square tube of 3050 mm height duly strengthened by 25 mm x 5 mm M/s flat iron on edges on back firmly fixed to the ground by means of properly designed foundations with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701 As per MORD - 2014

10.8

-

-

... More
Providing and fixing of retro- reflectorised informatory sign board rectangular/Square in shape having area less than 0.9 One Square Meterr made out of ____mm aluminum sheet bonded with white retro reflective sheeting of Class __ ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3, supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with two coats of grey stove enamel paint and supported on one no. mild steel angle iron post 75 mm x 75 mm x 6 mm, 3.5 mt long firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing The angle iron post shall be duly painted with one coat of epoxy primer and two coats of epoxy finish paints having alternate black and white bands of 25 cm width including GI fixures and transportation etc.complete.The nut bolts of board with angle iron post/supporting structure after fixing at site has to be electrically welded. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) sheeting shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier.

21.6

-

-

... More
Providing white and colour washing to road side trees Providing white and colour washing to road side trees in 2 coats in 2 bands of white and one red band at centre of 30 cm height each including preparing the surface, cost of material, conveying etc. complete.

40

-

-

... More
Metal Beam Crash Barrier -- Type - A, W : Metal Beam Crash Barrier (Providing and erecting a W metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810)""

60

-

-

... More
Supplying and Fixing of Cat's Eye Supplying and Fixing of Molded Shank Raised Pavement Markers / Cat's Eye made of polycarbonate and ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face and shall support a load of 16000 kg tested in accordance to ASTM D 4280 Type H and complying to Specifications of Category A of MORTH Circular No RW/NH/33023/10-97 DO III Dt 11.06. 1997. The height, width and length shall not exceed 50 mm, 100 mm and 102 +/- 2 mm and with minimum reflective area of 13 Sqcm on each side and the slope to the base shall be 35 +/- 5 degree. The strength of detachment of the integrated cylindrical shanks, (of diameter not less than 19 +/- 2 mm and height not less than 30+/- 2 mm) from the body is to be a minimum value of 500 Kg. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturer's recommendation and complete as directed by the engineer.The contractor shall submit a two year warranty for satisfactory field performance including stipulated retro-reflectance of the reflecting panel, to the Engineer.

240

-

-

... More
Road Marking with Thermoplastic Compound Road Marking with Hot Applied Thermoplastic Compound with Reflectorizing Glass Beads on Bituminous Surface- Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorizing glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.complete.

75.2

-

-

... More
Providing Vertical Delineator having wide angle cube corner micro prismatic non metallic reflective sheeting confirming to Type XI of ASTM D4956 -09 with White Color and Red Color combination and having minimum of retro reflective exposed area of 125 Sq CM on top slots and 35 Sq CM on bottom slots and no edges shall be exposed for tampering. This tubular delineator shall have a core and shell construction, shell shall be made of tough, high impact resistant, injection-molded, thermoplastic outer body and the inner core shall consist of powder coated or painted Mild steel of minimum thickness 1.0mm.and core-shell structure shall be of height not less than 800 mm above the ground and width not less than 80 mm. The metallic core of the delineator shall extend 300mm beyond the shell length from bottom for installing in the ground. The extended portion shall have slots to insert anchoring rods for enhancing the concrete grip. The logo of the manufacturer shall be embossed on either side of the body in the injection molding process. The engineering thermoplastic used for making the delineator body shall have minimum initial mechanical properties of 600J/m tested in accordance with ASTM D256 and shall retain at least 70% of these minimum initial values when subjected to accelerated weathering for 1000hrs as per ASTM G155 or UL 746C and as per IRC 79 specifications and including fixing the unit in M20 Grade Cement Concrete of Size 30x30x40 cm including excavation for pit.

48

-

-

... More
Providing and fixing Cautionary/Warning sign boards in Equilateral Triangle size of 600 mm made out of 1.5mm aluminum sheet bonded with white retro reflective sheeting of Class C ( Type XI Micro prismatic grade sheeting) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3 Supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with grey stove enamel paint and supported on one no. of M. S. angle iron post of size 65 mm X 65 mm X 6 mm, 3.45 m long, duly painted with with flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in M25 grade concrete block of size 60cm X 60cm X 75cm including transportation etc; complete. ClassC ( Type XI Micro prismatic grade sheeting) shall have 10 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier.

20

-

-

... More
Providing and fixing Mandatory/Regulatory sign boards in circular shape of 600 mm dia made out of 3mm aluminum composite material ( ACM) sheet bonded with white retro reflective sheeting of Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3 Supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with grey stove enamel paint and supported on one no. of M. S. angle iron post of size 65 mm X 65 mm X 6 mm, 3.45 m long, duly painted with with flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in M25 grade concrete block of size 60cm X 60cm X 75cm including transportation etc; complete. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier.

32

-

-

... More
Providing & fixing Hazard markers board Providing & fixing Hazard markers board in rectangular shape of size 0.30x0.90m made out of 16 guage (1.60mm) thick M.S.sheet with angle frame 25X25X5 mm for pannel ,black non reflective opaque back ground and yellow oblique engineering grade reflective bands & back side in gray stove enamal paint etc complete ,including one MS.angle iron post of 50mmx50mmx6mm 1.8 mtr long painted with synthetick enamel paint of black colour including in G.I.fixture etc & fixing the board in 1:2.5:3 (M-15 Grade) concrete block of size 45cm x45cmx60cm .including transportation etc . complete

52

-

-

... More
MMGSY / PMGSY Maintenance Information Board Providing and fixing of typical MMGSY / PMGSY Retro Reflective information board as per section 1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing.The ACP sheets of 3 mm thick, of 1500mmx900 mm size duly rivetted with MS angles of 25 x 25 x 5 mm thick M.S angle. Riveting of all the sheets over angle and flat iron frame will be done neatly to have plain surface on one side. The angle iron frame of the plate will be welded to two nos. 75mm x75mm (12 SWG) sheet tubes posts placed at 1125mm apart centre to centre. These two posts will be embeded in cement concrete M15 grade block of 600x600x750mm below ground level. The height of the bottom of the plate will be 775mm from normal ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications. All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.5 and as directed by Engineer-In-charge. . A warranty for 5 / 7 years for the Retro reflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor.

1

-

-

... More
Improvement and 5 Years of Maintenance of Road from NH-03 to Mukne Road, (LR-02), (VR-134), KM :- 0/000 to 4/300, Taluka - Kalwan, District - Nashik.

-

-

-

... More
Site Clearance, Dismantling and Earth Works

-

-

-

... More
Clearing and Grubbing Road Land Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means In area of non-thorny jungle Technical Specification MoRD 2014 Clause 201.

0.65

-

-

... More
Clearing and Grubbing Road Land Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means In area of thorny jungle Technical Specification MoRD 2014 Clause 201.

0.65

-

-

... More
Excavation in Soil using Hydraulic Excavator and Tippers with disposal More than 100 m Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with a lift upto 1.5 m and lead More than 100 m Excavation in Soil using Hydraulic Excavator and Tippers with disposal More than 100 m Technical Specification MoRD 2014 Clause 302.3.

1790.1

-

-

... More
Excavation in Ordinary Rock using Hydraulic Excavator and Tippers with disposal More than 100 m Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, transporting to embankment site with a lift upto 1.5 m and lead More than 100 m, trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections. Technical Specification MoRD 2014 Clause 302.3.5

210.6

-

-

... More
Excavation in Hard Rock (requiring blasting) with disposal More than 100 m Excavation for roadway in hard rock (requiring blasting) by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross-sections, loading and disposal of cut rock with a lift upto 1.5 m and leads More than 100 m. Technical Specification MoRD 2014 Clause 302.3.5

105.3

-

-

... More
Construction of Embankment with Material Obtained from Roadway Cutting Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2. Technical Specification MoRD 2014 Tables 300.1 and 300.2 Clause 301.5.

1300.46

-

-

... More
Construction of Embankment with Material Obtained from Borrow Pits Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2. For lead upto 250 m Technical Specification MoRD 2014 Tables 300.1 and 300.2 Clause 301.5.

7575.52

-

-

... More
Scarifying Existing Surface to a Depth of 150 mm by Mechanical Means Scarifying the existing road surface to a depth of 150 mm and Sectioning for required width, watering and compaction of Scarified material with roller including all leads and lifts as per Technical Specification Clause 301.4., 303.5.2.

12040

-

-

... More
Pavement Works (GSB, WBM, Bituminous Works) and Cement Concrete Pavement Work

-

-

-

... More
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per Technical Specification Clause 401. By Using Crushed Aggregate.

2002.91

-

-

... More
Water Bound Macadam with Crushable Screenings WBM Grading 2 Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 2. By Manual Means Technical Specification MoRD 2014 Clause 405.

2092.88

-

-

... More
Construction of Subgrade and Earthen Shoulders. Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification MORD 2014, Clause 303.1.

2567.1

-

-

... More
Tack Coat Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared bituminous surface cleaned with Hydraulic broom. Technical Specification MoRD 2014 Clause 503

16290.5

-

-

... More
Modified Penetration Macadam Construction of penetration macadam over prepared base by providing a layer of compacted crushed coarse aggregate using chips spreader with alternate applications of bituminous binder and key aggregates and rolling with a three wheel 80-100 kN static roller to achieve the desired degree of compaction. 50 mm thick Bitumen (S-65) 60/70 - VG-30 Technical Specification MoRD 2004 Clause 506

16280

-

-

... More
20mm thick Open-Graded Premix Carpet using Bituminous (penetration grade/modified bitumen) Binder Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C. Case - II By Mechanical Means Bitumen (S-65) VG-30 using Waste Plastic Technical Specification MoRD 2014 Clause 506.

16290.5

-

-

... More
Seal Coat Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C By Mechanical Means Case - I : Type A Bitumen (S-65) VG-30 Technical Specification MoRD 2014 Clause 508.

16290.5

-

-

... More
Thin White Topping Providing and laying White Topping/Short Paneled Concrete as per IRC-SP 76-2015 (Existing surface preparation to be done if necessary either by milling or leveling course with DLC to correct surface profile and to be paid separately) with un reinforced M-40 grade Pavement Quality Concrete using Ordinary Portland Cement 43/53 Grade OR Portland Pozzolona Cement IS-1489 at 425kg/cum, coarse aggregate, fine aggregate(VSI) and Admixture confirming to IS 9130-1999 (R-2004) polymeric synthetic fiber as per ASTM (1116) such as polyester / polyethylene / polypropylene / Glass fiber at 1.20 kg/cum, mixed in batching and mixing plant or weigh batcher as per approved mix design to achieve minimum flexural strength or modulus of rupture of concrete 4.50 MPa at 28 days limiting maximum water cement ratio to 0.40, transported to site, laid with fixed form/ slip form paver finisher (preferably with slip form paver finisher), spread, vibrated, compacted and finished in a continuous operation to the lines and grades as per drawing, texture finishing of surface, spraying two layers of curing compound, curing with water sprayed on hessian cloth covered over concrete surface, groove cutting grid 1m x 1m or as directed by Engineer Incharge to a depth of 1/3 to 1/4 of the Thickness and of width 3-5 mm as per design including cost of all material, side form work, labour and machineries etc. complete as per specifications.(Excluding Dowel Bars and Tie Bars) (Crushed VSI Sand ) Including Polythene Sheet of 125 Micron.

168.75

-

-

... More
MS dowel Bars Providing and fixing in position 25mm dia anti corossive MS dowel Bars of requird Dia 60 cms. Long and at 30.00 cms C/C and Wherever derect include handing, straighting necessary cutting support by chairs with proper alignment with half length covert by polythin sheathing include cap etc.

78

-

-

... More
TMT FE 500 ,tie bars Providing and fixing in position anti corrossive TMT FE 500 ,tie bars of 12 mm dia 70 cms long and at 30.00cm C/C and Wherever directed inclueding handling neccesary cutting, handling support by assembly of TMT FE 500, chairs with proper alignment complete

1000

-

-

... More
Cross Drainage Structures (Culverts & Minor Bridges), Drains and Protection Works

-

-

-

... More
Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary soil Upto 3 m depth By Mannual means As per MORD - 2014 Specification clause No. 305

193.61

-

-

... More
Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary rock (not requiring blasting) Upto 3 m depth As per MORD - 2014 Specification clause No. 305

100.56

-

-

... More
Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Hard rock (requiring Prohibeted) Upto 3 m depth including 1.5 m depth in hard rock As per MORD - 2014 Specification clause No. 305

16.09

-

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications as per MORD - 2014 Clause 802, 803, 1202 & 1203 P.C.C grade M 10 Nominal mix 1:3:6

34.28

-

-

... More
Providing and Laying Reinforced Cement Concrete Pipe NP3 as per design Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets As per MORD Specification 2014 Clause No. 1100. 1000 mm dia

40

-

-

... More
Providing and Laying Reinforced Cement Concrete Pipe NP2 as per design Providing and laying reinforced cement concrete pipe NP2 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets As per MORD Specification 2014 Clause No. 1100. 300 mm dia NP-2 Pipe

60

-

-

... More
Providing and Laying Reinforced Cement Concrete Pipe NP3 as per design Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets As per MORD Specification 2014 Clause No.1100. 600 mm dia NP-3 Pipe

61

-

-

... More
Painting Two Coats on New Concrete Surfaces Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surfaces as per drawing and Technical Specification MORD 2014 Clause 1701

0.9

-

-

... More
Printing New Letters and Figures of any Shade Printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade as per drawings and Technical Specification MORD 2014 Clause 1701 English and Roman Hyphens, commas and the like not to be measured and paid for. Detail for 100 letters of 160 mm height, i.e., 1600 cm

80

-

-

... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification MORD 2014 Clauses 614, 709 P.V.C. pipe 100 mm dia

26

-

-

... More
Pitching on slopes Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1302

69.66

-

-

... More
P. C. C. grade M - 15 Concrete Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204

134.25

-

-

... More
P. C. C. grade M - 15 ConcretePlain / reinforced cement concrete grade M-15 (Nominal Mix (1:2.5:5)

165.45

-

-

... More
Traffic Signs, Markings and Road Appurtenances, Road Safety & Road Furniture

-

-

-

... More
Kilometre Stone Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014, Clause 1703 Kilometre Stone (precast)

5

-

-

... More
Kilometre Stone Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014, Clause 1703 200 m Stone

18

-

-

... More
Providing Guard stone/ boundary stone Providing and fixing trap /granite/ quartzite/ gneiss/ guard stone/ indicator stones/ boundry stones of standard size & shape including fixing In ground and white washing complete Spec. No.: As per MORTH Specification Clause No. 807

499

-

-

... More
Citizen Information Board Providing and fixing a typical MMGSY Citizen information board as per specification provided on detailed drawing of NRRDA having frame size of 2500 x 1150 mm with 75 mm square or round steel tube for support fixed in a concrete block of 60 x 60 x 75 cm size. Information as provided in drawing of NRRDA shall be displayed on a CR/GI sheet of appropriate thickness and fixed at steel frame with 5 mm steel plate. All lettering and painting arrows border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and coloured as mentioned in detailed drawing. All sections of framed posts and steel tube shall be painted with primer and two coat of epoxy paint as per drawings. Rate As per RD and WC Deptt. No. CMGSY - 2007 / CR / 145 / Yojana - 9 Dt. 04 / 04 / 2007

1

-

-

... More
Providing and Fixing 'Logo' of MMGSY Project Providing and fixing of typical MMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 as per MORD - 2014

1

-

-

... More
Direction and Place Identification signs upto 0.9 sqm size board B. Semi-Reflective Traffic signs Direction and place indentification signs up to 0.9 sqm size board Providing and erecting direction and place identifications of semi reflective sign boards as per IRC:67 made of 2 mm thick M.S. Sheet duly stove enameled paint in white colour in front and grey colour on back with red reflective border of 70 mm width and required message, letters, figures with reflective engineering grade tape as per MORD specifications of required shade and colour. Supported and welded on 47 mm x 47mm of 12 SWG Square tube of 3050 mm height duly strengthened by 25 mm x 5 mm M/s flat iron on edges on back firmly fixed to the ground by means of properly designed foundations with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701 As per MORD - 2014

8.64

-

-

... More
Providing and fixing of retro- reflectorised informatory sign board rectangular/Square in shape having area less than 0.9 One Square Meterr made out of ____mm aluminum sheet bonded with white retro reflective sheeting of Class __ ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3, supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with two coats of grey stove enamel paint and supported on one no. mild steel angle iron post 75 mm x 75 mm x 6 mm, 3.5 mt long firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing The angle iron post shall be duly painted with one coat of epoxy primer and two coats of epoxy finish paints having alternate black and white bands of 25 cm width including GI fixures and transportation etc.complete.The nut bolts of board with angle iron post/supporting structure after fixing at site has to be electrically welded. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) sheeting shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier.

12.96

-

-

... More
Providing white and colour washing to road side trees Providing white and colour washing to road side trees in 2 coats in 2 bands of white and one red band at centre of 30 cm height each including preparing the surface, cost of material, conveying etc. complete.

40

-

-

... More
Metal Beam Crash Barrier -- Type - A, W : Metal Beam Crash Barrier (Providing and erecting a W metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810)""

30

-

-

... More
Supplying and Fixing of Cat's Eye Supplying and Fixing of Molded Shank Raised Pavement Markers / Cat's Eye made of polycarbonate and ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face and shall support a load of 16000 kg tested in accordance to ASTM D 4280 Type H and complying to Specifications of Category A of MORTH Circular No RW/NH/33023/10-97 DO III Dt 11.06. 1997. The height, width and length shall not exceed 50 mm, 100 mm and 102 +/- 2 mm and with minimum reflective area of 13 Sqcm on each side and the slope to the base shall be 35 +/- 5 degree. The strength of detachment of the integrated cylindrical shanks, (of diameter not less than 19 +/- 2 mm and height not less than 30+/- 2 mm) from the body is to be a minimum value of 500 Kg. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturer's recommendation and complete as directed by the engineer.The contractor shall submit a two year warranty for satisfactory field performance including stipulated retro-reflectance of the reflecting panel, to the Engineer.

160

-

-

... More
Road Marking with Thermoplastic Compound Road Marking with Hot Applied Thermoplastic Compound with Reflectorizing Glass Beads on Bituminous Surface- Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorizing glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.complete.

83.2

-

-

... More
Providing Vertical Delineator having wide angle cube corner micro prismatic non metallic reflective sheeting confirming to Type XI of ASTM D4956 -09 with White Color and Red Color combination and having minimum of retro reflective exposed area of 125 Sq CM on top slots and 35 Sq CM on bottom slots and no edges shall be exposed for tampering. This tubular delineator shall have a core and shell construction, shell shall be made of tough, high impact resistant, injection-molded, thermoplastic outer body and the inner core shall consist of powder coated or painted Mild steel of minimum thickness 1.0mm.and core-shell structure shall be of height not less than 800 mm above the ground and width not less than 80 mm. The metallic core of the delineator shall extend 300mm beyond the shell length from bottom for installing in the ground. The extended portion shall have slots to insert anchoring rods for enhancing the concrete grip. The logo of the manufacturer shall be embossed on either side of the body in the injection molding process. The engineering thermoplastic used for making the delineator body shall have minimum initial mechanical properties of 600J/m tested in accordance with ASTM D256 and shall retain at least 70% of these minimum initial values when subjected to accelerated weathering for 1000hrs as per ASTM G155 or UL 746C and as per IRC 79 specifications and including fixing the unit in M20 Grade Cement Concrete of Size 30x30x40 cm including excavation for pit.

40

-

-

... More
Providing and fixing Cautionary/Warning sign boards in Equilateral Triangle size of 600 mm made out of 1.5mm aluminum sheet bonded with white retro reflective sheeting of Class C ( Type XI Micro prismatic grade sheeting) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3 Supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with grey stove enamel paint and supported on one no. of M. S. angle iron post of size 65 mm X 65 mm X 6 mm, 3.45 m long, duly painted with with flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in M25 grade concrete block of size 60cm X 60cm X 75cm including transportation etc; complete. ClassC ( Type XI Micro prismatic grade sheeting) shall have 10 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier.

20

-

-

... More
Providing and fixing Mandatory/Regulatory sign boards in circular shape of 600 mm dia made out of 3mm aluminum composite material ( ACM) sheet bonded with white retro reflective sheeting of Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3 Supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with grey stove enamel paint and supported on one no. of M. S. angle iron post of size 65 mm X 65 mm X 6 mm, 3.45 m long, duly painted with with flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in M25 grade concrete block of size 60cm X 60cm X 75cm including transportation etc; complete. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier.

24

-

-

... More
MMGSY / PMGSY Maintenance Information Board Providing and fixing of typical MMGSY / PMGSY Retro Reflective information board as per section 1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing.The ACP sheets of 3 mm thick, of 1500mmx900 mm size duly rivetted with MS angles of 25 x 25 x 5 mm thick M.S angle. Riveting of all the sheets over angle and flat iron frame will be done neatly to have plain surface on one side. The angle iron frame of the plate will be welded to two nos. 75mm x75mm (12 SWG) sheet tubes posts placed at 1125mm apart centre to centre. These two posts will be embeded in cement concrete M15 grade block of 600x600x750mm below ground level. The height of the bottom of the plate will be 775mm from normal ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications. All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.5 and as directed by Engineer-In-charge. . A warranty for 5 / 7 years for the Retro reflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor.

1

-

-

... More
Providing & fixing Hazard markers board Providing & fixing Hazard markers board in rectangular shape of size 0.30x0.90m made out of 16 guage (1.60mm) thick M.S.sheet with angle frame 25X25X5 mm for pannel ,black non reflective opaque back ground and yellow oblique engineering grade reflective bands & back side in gray stove enamal paint etc complete ,including one MS.angle iron post of 50mmx50mmx6mm 1.8 mtr long painted with synthetick enamel paint of black colour including in G.I.fixture etc & fixing the board in 1:2.5:3 (M-15 Grade) concrete block of size 45cm x45cmx60cm .including transportation etc . complete

44

-

-

... More
Improvement and 5 Years of Maintenance of Road from Pardevi to Igatpuri Road, (LR-32),(VR-20), KM :- 0/000 to 4/300, Taluka - Igatpuri, District - Nashik.

-

-

-

... More
Site Clearance, Dismantling and Earth Works

-

-

-

... More
Clearing and Grubbing Road Land Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means In area of non-thorny jungle Technical Specification MoRD 2014 Clause 201.

0.65

-

-

... More
Clearing and Grubbing Road Land Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means In area of thorny jungle Technical Specification MoRD 2014 Clause 201.

0.65

-

-

... More
Excavation in Soil using Hydraulic Excavator and Tippers with disposal More than 100 m Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with a lift upto 1.5 m and lead More than 100 m Excavation in Soil using Hydraulic Excavator and Tippers with disposal More than 100 m Technical Specification MoRD 2014 Clause 302.3.

28181.65

-

-

... More
Excavation in Ordinary Rock using Hydraulic Excavator and Tippers with disposal More than 100 m Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, transporting to embankment site with a lift upto 1.5 m and lead More than 100 m, trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections. Technical Specification MoRD 2014 Clause 302.3.5

3315.49

-

-

... More
Excavation in Hard Rock (requiring blasting) with disposal More than 100 m Excavation for roadway in hard rock (requiring blasting) by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross-sections, loading and disposal of cut rock with a lift upto 1.5 m and leads More than 100 m. Technical Specification MoRD 2014 Clause 302.3.5

1657.74

-

-

... More
Construction of Embankment with Material Obtained from Roadway Cutting Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2. Technical Specification MoRD 2014 Tables 300.1 and 300.2 Clause 301.5.

9327.45

-

-

... More
Construction of Embankment with Material Obtained from Borrow Pits Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2. For lead upto 250 m Technical Specification MoRD 2014 Tables 300.1 and 300.2 Clause 301.5.

1469.36

-

-

... More
Scarifying Existing Surface to a Depth of 150 mm by Mechanical Means Scarifying the existing road surface to a depth of 150 mm and Sectioning for required width, watering and compaction of Scarified material with roller including all leads and lifts as per Technical Specification Clause 301.4., 303.5.2.

12000

-

-

... More
Dismantling Stone Masonry. Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m. Rubble Stone Masonry in Cement Mortar Technical Specification MoRD 2014 Clause 202.

33.33

-

-

... More
Removing all types of Hume pipes and stacking within a lead of 1000 m including Earthwork and Dismantling of Masonry Works. Above 600 mm to 900 mm dia Hume pipe Technical Specification MoRD 2014 Clause 202.

22.5

-

-

... More
Pavement Works (GSB, WBM, Bituminous Works) and Cement Concrete Pavement Work

-

-

-

... More
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per Technical Specification Clause 401. By Using Crushed Aggregate.

2785.71

-

-

... More
Water Bound Macadam with Crushable Screenings WBM Grading 2 Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 2. By Manual Means Technical Specification MoRD 2014 Clause 405.

2214.44

-

-

... More
Construction of Subgrade and Earthen Shoulders. Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification MORD 2014, Clause 303.1.

1677

-

-

... More
Tack Coat Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared bituminous surface cleaned with Hydraulic broom. Technical Specification MoRD 2014 Clause 503

12529.62

-

-

... More
Modified Penetration Macadam Construction of penetration macadam over prepared base by providing a layer of compacted crushed coarse aggregate using chips spreader with alternate applications of bituminous binder and key aggregates and rolling with a three wheel 80-100 kN static roller to achieve the desired degree of compaction. 50 mm thick Bitumen (S-65) 60/70 - VG-30 Technical Specification MoRD 2004 Clause 506

13089.62

-

-

... More
20mm thick Open-Graded Premix Carpet using Bituminous (penetration grade/modified bitumen) Binder Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C. Case - II By Mechanical Means Bitumen (S-65) VG-30 using Waste Plastic Technical Specification MoRD 2014 Clause 506.

12529.62

-

-

... More
Seal Coat Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C By Mechanical Means Case - I : Type A Bitumen (S-65) VG-30 Technical Specification MoRD 2014 Clause 508.

12529.62

-

-

... More
Dry lean cement concrete Sub-base Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate ( natural sand/ VSI grade finely washed crushed sand) conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, , cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor /by suitable means as approved by Engineer-in- charge , compacting with vibratory roller, finishing, curing and including preparation of sub-grade surface if required etc. complete. with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete.

364.5

-

-

... More
Thin White Topping Providing and laying White Topping/Short Paneled Concrete as per IRC-SP 76-2015 (Existing surface preparation to be done if necessary either by milling or leveling course with DLC to correct surface profile and to be paid separately) with un reinforced M-40 grade Pavement Quality Concrete using Ordinary Portland Cement 43/53 Grade OR Portland Pozzolona Cement IS-1489 at 425kg/cum, coarse aggregate, fine aggregate(VSI) and Admixture confirming to IS 9130-1999 (R-2004) polymeric synthetic fiber as per ASTM (1116) such as polyester / polyethylene / polypropylene / Glass fiber at 1.20 kg/cum, mixed in batching and mixing plant or weigh batcher as per approved mix design to achieve minimum flexural strength or modulus of rupture of concrete 4.50 MPa at 28 days limiting maximum water cement ratio to 0.40, transported to site, laid with fixed form/ slip form paver finisher (preferably with slip form paver finisher), spread, vibrated, compacted and finished in a continuous operation to the lines and grades as per drawing, texture finishing of surface, spraying two layers of curing compound, curing with water sprayed on hessian cloth covered over concrete surface, groove cutting grid 1m x 1m or as directed by Engineer Incharge to a depth of 1/3 to 1/4 of the Thickness and of width 3-5 mm as per design including cost of all material, side form work, labour and machineries etc. complete as per specifications.(Excluding Dowel Bars and Tie Bars) (Crushed VSI Sand ) Including Polythene Sheet of 125 Micron.

590.63

-

-

... More
MS dowel Bars Providing and fixing in position 25mm dia anti corossive MS dowel Bars of requird Dia 60 cms. Long and at 30.00 cms C/C and Wherever derect include handing, straighting necessary cutting support by chairs with proper alignment with half length covert by polythin sheathing include cap etc.

156

-

-

... More
TMT FE 500 ,tie bars Providing and fixing in position anti corrossive TMT FE 500 ,tie bars of 12 mm dia 70 cms long and at 30.00cm C/C and Wherever directed inclueding handling neccesary cutting, handling support by assembly of TMT FE 500, chairs with proper alignment complete

2000

-

-

... More
Cross Drainage Structures (Culverts & Minor Bridges), Drains and Protection Works

-

-

-

... More
Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary soil Upto 3 m depth By Mannual means As per MORD - 2014 Specification clause No. 305

336.06

-

-

... More
Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary rock (not requiring blasting) Upto 3 m depth As per MORD - 2014 Specification clause No. 305

179.32

-

-

... More
Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Hard rock (requiring Prohibeted) Upto 3 m depth including 1.5 m depth in hard rock As per MORD - 2014 Specification clause No. 305

25.74

-

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications as per MORD - 2014 Clause 802, 803, 1202 & 1203 P.C.C grade M 10 Nominal mix 1:3:6

59.11

-

-

... More
Providing and Laying Reinforced Cement Concrete Pipe NP3 as per design Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets As per MORD Specification 2014 Clause No. 1100. 1000 mm dia

75

-

-

... More
Providing and Laying Reinforced Cement Concrete Pipe NP2 as per design Providing and laying reinforced cement concrete pipe NP2 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets As per MORD Specification 2014 Clause No. 1100. 300 mm dia NP-2 Pipe

90

-

-

... More
Providing and Laying Reinforced Cement Concrete Pipe NP3 as per design Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets As per MORD Specification 2014 Clause No.1100. 600 mm dia NP-3 Pipe

55

-

-

... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification MORD 2014 Clauses 614, 709 P.V.C. pipe 100 mm dia

84

-

-

... More
Pitching on slopes Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1302

81.27

-

-

... More
P. C. C. grade M - 15 Concrete Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204

214.8

-

-

... More
P. C. C. grade M - 15 ConcretePlain / reinforced cement concrete grade M-15 (Nominal Mix (1:2.5:5)

310.09

-

-

... More
Traffic Signs, Markings and Road Appurtenances, Road Safety & Road Furniture

-

-

-

... More
Kilometre Stone Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014, Clause 1703 Kilometre Stone (precast)

5

-

-

... More
Kilometre Stone Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014, Clause 1703 200 m Stone

18

-

-

... More
Providing Guard stone/ boundary stone Providing and fixing trap /granite/ quartzite/ gneiss/ guard stone/ indicator stones/ boundry stones of standard size & shape including fixing In ground and white washing complete Spec. No.: As per MORTH Specification Clause No. 807

646

-

-

... More
Citizen Information Board Providing and fixing a typical MMGSY Citizen information board as per specification provided on detailed drawing of NRRDA having frame size of 2500 x 1150 mm with 75 mm square or round steel tube for support fixed in a concrete block of 60 x 60 x 75 cm size. Information as provided in drawing of NRRDA shall be displayed on a CR/GI sheet of appropriate thickness and fixed at steel frame with 5 mm steel plate. All lettering and painting arrows border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and coloured as mentioned in detailed drawing. All sections of framed posts and steel tube shall be painted with primer and two coat of epoxy paint as per drawings. Rate As per RD and WC Deptt. No. CMGSY - 2007 / CR / 145 / Yojana - 9 Dt. 04 / 04 / 2007

1

-

-

... More
Providing and Fixing 'Logo' of MMGSY Project Providing and fixing of typical MMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 as per MORD - 2014

1

-

-

... More
Direction and Place Identification signs upto 0.9 sqm size board B. Semi-Reflective Traffic signs Direction and place indentification signs up to 0.9 sqm size board Providing and erecting direction and place identifications of semi reflective sign boards as per IRC:67 made of 2 mm thick M.S. Sheet duly stove enameled paint in white colour in front and grey colour on back with red reflective border of 70 mm width and required message, letters, figures with reflective engineering grade tape as per MORD specifications of required shade and colour. Supported and welded on 47 mm x 47mm of 12 SWG Square tube of 3050 mm height duly strengthened by 25 mm x 5 mm M/s flat iron on edges on back firmly fixed to the ground by means of properly designed foundations with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701 As per MORD - 2014

25.92

-

-

... More
Providing and fixing of retro- reflectorised informatory sign board rectangular/Square in shape having area less than 0.9 One Square Meterr made out of ____mm aluminum sheet bonded with white retro reflective sheeting of Class __ ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3, supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with two coats of grey stove enamel paint and supported on one no. mild steel angle iron post 75 mm x 75 mm x 6 mm, 3.5 mt long firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing The angle iron post shall be duly painted with one coat of epoxy primer and two coats of epoxy finish paints having alternate black and white bands of 25 cm width including GI fixures and transportation etc.complete.The nut bolts of board with angle iron post/supporting structure after fixing at site has to be electrically welded. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) sheeting shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier.

32.4

-

-

... More
Providing white and colour washing to road side trees Providing white and colour washing to road side trees in 2 coats in 2 bands of white and one red band at centre of 30 cm height each including preparing the surface, cost of material, conveying etc. complete.

40

-

-

... More
Metal Beam Crash Barrier -- Type - A, W : Metal Beam Crash Barrier (Providing and erecting a W metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810)""

90

-

-

... More
Supplying and Fixing of Cat's Eye Supplying and Fixing of Molded Shank Raised Pavement Markers / Cat's Eye made of polycarbonate and ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face and shall support a load of 16000 kg tested in accordance to ASTM D 4280 Type H and complying to Specifications of Category A of MORTH Circular No RW/NH/33023/10-97 DO III Dt 11.06. 1997. The height, width and length shall not exceed 50 mm, 100 mm and 102 +/- 2 mm and with minimum reflective area of 13 Sqcm on each side and the slope to the base shall be 35 +/- 5 degree. The strength of detachment of the integrated cylindrical shanks, (of diameter not less than 19 +/- 2 mm and height not less than 30+/- 2 mm) from the body is to be a minimum value of 500 Kg. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturer's recommendation and complete as directed by the engineer.The contractor shall submit a two year warranty for satisfactory field performance including stipulated retro-reflectance of the reflecting panel, to the Engineer.

240

-

-

... More
Road Marking with Thermoplastic Compound Road Marking with Hot Applied Thermoplastic Compound with Reflectorizing Glass Beads on Bituminous Surface- Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorizing glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.complete.

197.2

-

-

... More
Providing Vertical Delineator having wide angle cube corner micro prismatic non metallic reflective sheeting confirming to Type XI of ASTM D4956 -09 with White Color and Red Color combination and having minimum of retro reflective exposed area of 125 Sq CM on top slots and 35 Sq CM on bottom slots and no edges shall be exposed for tampering. This tubular delineator shall have a core and shell construction, shell shall be made of tough, high impact resistant, injection-molded, thermoplastic outer body and the inner core shall consist of powder coated or painted Mild steel of minimum thickness 1.0mm.and core-shell structure shall be of height not less than 800 mm above the ground and width not less than 80 mm. The metallic core of the delineator shall extend 300mm beyond the shell length from bottom for installing in the ground. The extended portion shall have slots to insert anchoring rods for enhancing the concrete grip. The logo of the manufacturer shall be embossed on either side of the body in the injection molding process. The engineering thermoplastic used for making the delineator body shall have minimum initial mechanical properties of 600J/m tested in accordance with ASTM D256 and shall retain at least 70% of these minimum initial values when subjected to accelerated weathering for 1000hrs as per ASTM G155 or UL 746C and as per IRC 79 specifications and including fixing the unit in M20 Grade Cement Concrete of Size 30x30x40 cm including excavation for pit.

76

-

-

... More
Providing and fixing Cautionary/Warning sign boards in Equilateral Triangle size of 600 mm made out of 1.5mm aluminum sheet bonded with white retro reflective sheeting of Class C ( Type XI Micro prismatic grade sheeting) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3 Supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with grey stove enamel paint and supported on one no. of M. S. angle iron post of size 65 mm X 65 mm X 6 mm, 3.45 m long, duly painted with with flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in M25 grade concrete block of size 60cm X 60cm X 75cm including transportation etc; complete. ClassC ( Type XI Micro prismatic grade sheeting) shall have 10 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier.

20

-

-

... More
Providing and fixing Mandatory/Regulatory sign boards in circular shape of 600 mm dia made out of 3mm aluminum composite material ( ACM) sheet bonded with white retro reflective sheeting of Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3 Supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with grey stove enamel paint and supported on one no. of M. S. angle iron post of size 65 mm X 65 mm X 6 mm, 3.45 m long, duly painted with with flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in M25 grade concrete block of size 60cm X 60cm X 75cm including transportation etc; complete. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier.

32

-

-

... More
Providing & fixing Hazard markers board Providing & fixing Hazard markers board in rectangular shape of size 0.30x0.90m made out of 16 guage (1.60mm) thick M.S.sheet with angle frame 25X25X5 mm for pannel ,black non reflective opaque back ground and yellow oblique engineering grade reflective bands & back side in gray stove enamal paint etc complete ,including one MS.angle iron post of 50mmx50mmx6mm 1.8 mtr long painted with synthetick enamel paint of black colour including in G.I.fixture etc & fixing the board in 1:2.5:3 (M-15 Grade) concrete block of size 45cm x45cmx60cm .including transportation etc . complete

64

-

-

... More
MMGSY / PMGSY Maintenance Information Board Providing and fixing of typical MMGSY / PMGSY Retro Reflective information board as per section 1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing.The ACP sheets of 3 mm thick, of 1500mmx900 mm size duly rivetted with MS angles of 25 x 25 x 5 mm thick M.S angle. Riveting of all the sheets over angle and flat iron frame will be done neatly to have plain surface on one side. The angle iron frame of the plate will be welded to two nos. 75mm x75mm (12 SWG) sheet tubes posts placed at 1125mm apart centre to centre. These two posts will be embeded in cement concrete M15 grade block of 600x600x750mm below ground level. The height of the bottom of the plate will be 775mm from normal ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications. All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.5 and as directed by Engineer-In-charge. . A warranty for 5 / 7 years for the Retro reflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor.

1

-

-

... More
Improvement and 5 Years of Maintenance of Road from Igatpuri to Awalkhed Road (LR-33 ), (VR-19, 175) Road KM :- 0/000 to 4/100, Branch :- 0/000 to 1/000 Taluka - Igatpuri, District - Nashik.

-

-

-

... More
Site Clearance, Dismantling and Earth Works

-

-

-

... More
Clearing and Grubbing Road Land Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means In area of non-thorny jungle Technical Specification MoRD 2014 Clause 201.

0.77

-

-

... More
Clearing and Grubbing Road Land Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means In area of thorny jungle Technical Specification MoRD 2014 Clause 201.

0.77

-

-

... More
Excavation in Soil using Hydraulic Excavator and Tippers with disposal More than 100 m Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with a lift upto 1.5 m and lead More than 100 m Excavation in Soil using Hydraulic Excavator and Tippers with disposal More than 100 m Technical Specification MoRD 2014 Clause 302.3.

5517.44

-

-

... More
Excavation in Ordinary Rock using Hydraulic Excavator and Tippers with disposal More than 100 m Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, transporting to embankment site with a lift upto 1.5 m and lead More than 100 m, trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections. Technical Specification MoRD 2014 Clause 302.3.5

649.11

-

-

... More
Excavation in Hard Rock (requiring blasting) with disposal More than 100 m Excavation for roadway in hard rock (requiring blasting) by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross-sections, loading and disposal of cut rock with a lift upto 1.5 m and leads More than 100 m. Technical Specification MoRD 2014 Clause 302.3.5

324.56

-

-

... More
Construction of Embankment with Material Obtained from Roadway Cutting Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2. Technical Specification MoRD 2014 Tables 300.1 and 300.2 Clause 301.5.

4008.26

-

-

... More
Construction of Embankment with Material Obtained from Borrow Pits Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2. For lead upto 250 m Technical Specification MoRD 2014 Tables 300.1 and 300.2 Clause 301.5.

6881.86

-

-

... More
Scarifying Existing Surface to a Depth of 150 mm by Mechanical Means Scarifying the existing road surface to a depth of 150 mm and Sectioning for required width, watering and compaction of Scarified material with roller including all leads and lifts as per Technical Specification Clause 301.4., 303.5.2.

6000

-

-

... More
Dismantling Stone Masonry. Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m. Rubble Stone Masonry in Cement Mortar Technical Specification MoRD 2014 Clause 202.

33.33

-

-

... More
Removing all types of Hume pipes and stacking within a lead of 1000 m including Earthwork and Dismantling of Masonry Works. Above 600 mm to 900 mm dia Hume pipe Technical Specification MoRD 2014 Clause 202.

22.5

-

-

... More
Pavement Works (GSB, WBM, Bituminous Works) and Cement Concrete Pavement Work

-

-

-

... More
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per Technical Specification Clause 401. By Using Crushed Aggregate.

2929.66

-

-

... More
Water Bound Macadam with Crushable Screenings WBM Grading 2 Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 2. By Manual Means Technical Specification MoRD 2014 Clause 405.

2831.85

-

-

... More
Construction of Subgrade and Earthen Shoulders. Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification MORD 2014, Clause 303.1.

1989

-

-

... More
Tack Coat Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared bituminous surface cleaned with Hydraulic broom. Technical Specification MoRD 2014 Clause 503

21222.34

-

-

... More
Modified Penetration Macadam Construction of penetration macadam over prepared base by providing a layer of compacted crushed coarse aggregate using chips spreader with alternate applications of bituminous binder and key aggregates and rolling with a three wheel 80-100 kN static roller to achieve the desired degree of compaction. 50 mm thick Bitumen (S-65) 60/70 - VG-30 Technical Specification MoRD 2004 Clause 506

21222.34

-

-

... More
20mm thick Open-Graded Premix Carpet using Bituminous (penetration grade/modified bitumen) Binder Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C. Case - II By Mechanical Means Bitumen (S-65) VG-30 using Waste Plastic Technical Specification MoRD 2014 Clause 506.

21222.34

-

-

... More
Seal Coat Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C By Mechanical Means Case - I : Type A Bitumen (S-65) VG-30 Technical Specification MoRD 2014 Clause 508.

21222.34

-

-

... More
Cross Drainage Structures (Culverts & Minor Bridges), Drains and Protection Works

-

-

-

... More
Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary soil Upto 3 m depth By Mannual means As per MORD - 2014 Specification clause No. 305

398

-

-

... More
Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary rock (not requiring blasting) Upto 3 m depth As per MORD - 2014 Specification clause No. 305

201.08

-

-

... More
Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Hard rock (requiring Prohibeted) Upto 3 m depth including 1.5 m depth in hard rock As per MORD - 2014 Specification clause No. 305

21.45

-

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications as per MORD - 2014 Clause 802, 803, 1202 & 1203 P.C.C grade M 10 Nominal mix 1:3:6

67.86

-

-

... More
Providing and Laying Reinforced Cement Concrete Pipe NP3 as per design Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets As per MORD Specification 2014 Clause No. 1100. 1000 mm dia

97.5

-

-

... More
Providing and Laying Reinforced Cement Concrete Pipe NP2 as per design Providing and laying reinforced cement concrete pipe NP2 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets As per MORD Specification 2014 Clause No. 1100. 300 mm dia NP-2 Pipe

165

-

-

... More
Providing and Laying Reinforced Cement Concrete Pipe NP3 as per design Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets As per MORD Specification 2014 Clause No.1100. 600 mm dia NP-3 Pipe

105

-

-

... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification MORD 2014 Clauses 614, 709 P.V.C. pipe 100 mm dia

70

-

-

... More
Pitching on slopes Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1302

96.39

-

-

... More
P. C. C. grade M - 15 Concrete Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204

179

-

-

... More
P. C. C. grade M - 15 ConcretePlain / reinforced cement concrete grade M-15 (Nominal Mix (1:2.5:5)

397.77

-

-

... More
Traffic Signs, Markings and Road Appurtenances, Road Safety & Road Furniture

-

-

-

... More
Kilometre Stone Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014, Clause 1703 5th Kilometre Stone (precast)

1

-

-

... More
Kilometre Stone Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014, Clause 1703 Kilometre Stone (precast)

5

-

-

... More
Kilometre Stone Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014, Clause 1703 200 m Stone

21

-

-

... More
Providing Guard stone/ boundary stone Providing and fixing trap /granite/ quartzite/ gneiss/ guard stone/ indicator stones/ boundry stones of standard size & shape including fixing In ground and white washing complete Spec. No.: As per MORTH Specification Clause No. 807

552

-

-

... More
Citizen Information Board Providing and fixing a typical MMGSY Citizen information board as per specification provided on detailed drawing of NRRDA having frame size of 2500 x 1150 mm with 75 mm square or round steel tube for support fixed in a concrete block of 60 x 60 x 75 cm size. Information as provided in drawing of NRRDA shall be displayed on a CR/GI sheet of appropriate thickness and fixed at steel frame with 5 mm steel plate. All lettering and painting arrows border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and coloured as mentioned in detailed drawing. All sections of framed posts and steel tube shall be painted with primer and two coat of epoxy paint as per drawings. Rate As per RD and WC Deptt. No. CMGSY - 2007 / CR / 145 / Yojana - 9 Dt. 04 / 04 / 2007

1

-

-

... More
Providing and Fixing 'Logo' of MMGSY Project Providing and fixing of typical MMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 as per MORD - 2014

1

-

-

... More
Direction and Place Identification signs upto 0.9 sqm size board B. Semi-Reflective Traffic signs Direction and place indentification signs up to 0.9 sqm size board Providing and erecting direction and place identifications of semi reflective sign boards as per IRC:67 made of 2 mm thick M.S. Sheet duly stove enameled paint in white colour in front and grey colour on back with red reflective border of 70 mm width and required message, letters, figures with reflective engineering grade tape as per MORD specifications of required shade and colour. Supported and welded on 47 mm x 47mm of 12 SWG Square tube of 3050 mm height duly strengthened by 25 mm x 5 mm M/s flat iron on edges on back firmly fixed to the ground by means of properly designed foundations with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701 As per MORD - 2014

25.92

-

-

... More
Providing and fixing of retro- reflectorised informatory sign board rectangular/Square in shape having area less than 0.9 One Square Meterr made out of ____mm aluminum sheet bonded with white retro reflective sheeting of Class __ ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3, supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with two coats of grey stove enamel paint and supported on one no. mild steel angle iron post 75 mm x 75 mm x 6 mm, 3.5 mt long firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing The angle iron post shall be duly painted with one coat of epoxy primer and two coats of epoxy finish paints having alternate black and white bands of 25 cm width including GI fixures and transportation etc.complete.The nut bolts of board with angle iron post/supporting structure after fixing at site has to be electrically welded. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) sheeting shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier.

32.4

-

-

... More
Providing white and colour washing to road side trees Providing white and colour washing to road side trees in 2 coats in 2 bands of white and one red band at centre of 30 cm height each including preparing the surface, cost of material, conveying etc. complete.

40

-

-

... More
Metal Beam Crash Barrier -- Type - A, W : Metal Beam Crash Barrier (Providing and erecting a W metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810)""

90

-

-

... More
Supplying and Fixing of Cat's Eye Supplying and Fixing of Molded Shank Raised Pavement Markers / Cat's Eye made of polycarbonate and ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face and shall support a load of 16000 kg tested in accordance to ASTM D 4280 Type H and complying to Specifications of Category A of MORTH Circular No RW/NH/33023/10-97 DO III Dt 11.06. 1997. The height, width and length shall not exceed 50 mm, 100 mm and 102 +/- 2 mm and with minimum reflective area of 13 Sqcm on each side and the slope to the base shall be 35 +/- 5 degree. The strength of detachment of the integrated cylindrical shanks, (of diameter not less than 19 +/- 2 mm and height not less than 30+/- 2 mm) from the body is to be a minimum value of 500 Kg. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturer's recommendation and complete as directed by the engineer.The contractor shall submit a two year warranty for satisfactory field performance including stipulated retro-reflectance of the reflecting panel, to the Engineer.

240

-

-

... More
Road Marking with Thermoplastic Compound Road Marking with Hot Applied Thermoplastic Compound with Reflectorizing Glass Beads on Bituminous Surface- Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorizing glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.complete.

221.2

-

-

... More
Providing Vertical Delineator having wide angle cube corner micro prismatic non metallic reflective sheeting confirming to Type XI of ASTM D4956 -09 with White Color and Red Color combination and having minimum of retro reflective exposed area of 125 Sq CM on top slots and 35 Sq CM on bottom slots and no edges shall be exposed for tampering. This tubular delineator shall have a core and shell construction, shell shall be made of tough, high impact resistant, injection-molded, thermoplastic outer body and the inner core shall consist of powder coated or painted Mild steel of minimum thickness 1.0mm.and core-shell structure shall be of height not less than 800 mm above the ground and width not less than 80 mm. The metallic core of the delineator shall extend 300mm beyond the shell length from bottom for installing in the ground. The extended portion shall have slots to insert anchoring rods for enhancing the concrete grip. The logo of the manufacturer shall be embossed on either side of the body in the injection molding process. The engineering thermoplastic used for making the delineator body shall have minimum initial mechanical properties of 600J/m tested in accordance with ASTM D256 and shall retain at least 70% of these minimum initial values when subjected to accelerated weathering for 1000hrs as per ASTM G155 or UL 746C and as per IRC 79 specifications and including fixing the unit in M20 Grade Cement Concrete of Size 30x30x40 cm including excavation for pit.

88

-

-

... More
Providing and fixing Cautionary/Warning sign boards in Equilateral Triangle size of 600 mm made out of 1.5mm aluminum sheet bonded with white retro reflective sheeting of Class C ( Type XI Micro prismatic grade sheeting) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3 Supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with grey stove enamel paint and supported on one no. of M. S. angle iron post of size 65 mm X 65 mm X 6 mm, 3.45 m long, duly painted with with flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in M25 grade concrete block of size 60cm X 60cm X 75cm including transportation etc; complete. ClassC ( Type XI Micro prismatic grade sheeting) shall have 10 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier.

20

-

-

... More
Providing and fixing Mandatory/Regulatory sign boards in circular shape of 600 mm dia made out of 3mm aluminum composite material ( ACM) sheet bonded with white retro reflective sheeting of Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3 Supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with grey stove enamel paint and supported on one no. of M. S. angle iron post of size 65 mm X 65 mm X 6 mm, 3.45 m long, duly painted with with flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in M25 grade concrete block of size 60cm X 60cm X 75cm including transportation etc; complete. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier.

32

-

-

... More
MMGSY / PMGSY Maintenance Information Board Providing and fixing of typical MMGSY / PMGSY Retro Reflective information board as per section 1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing.The ACP sheets of 3 mm thick, of 1500mmx900 mm size duly rivetted with MS angles of 25 x 25 x 5 mm thick M.S angle. Riveting of all the sheets over angle and flat iron frame will be done neatly to have plain surface on one side. The angle iron frame of the plate will be welded to two nos. 75mm x75mm (12 SWG) sheet tubes posts placed at 1125mm apart centre to centre. These two posts will be embeded in cement concrete M15 grade block of 600x600x750mm below ground level. The height of the bottom of the plate will be 775mm from normal ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications. All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.5 and as directed by Engineer-In-charge. . A warranty for 5 / 7 years for the Retro reflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor.

1

-

-

... More
Providing & fixing Hazard markers board Providing & fixing Hazard markers board in rectangular shape of size 0.30x0.90m made out of 16 guage (1.60mm) thick M.S.sheet with angle frame 25X25X5 mm for pannel ,black non reflective opaque back ground and yellow oblique engineering grade reflective bands & back side in gray stove enamal paint etc complete ,including one MS.angle iron post of 50mmx50mmx6mm 1.8 mtr long painted with synthetick enamel paint of black colour including in G.I.fixture etc & fixing the board in 1:2.5:3 (M-15 Grade) concrete block of size 45cm x45cmx60cm .including transportation etc . complete

76

-

-

... More
Improvement and 5 Years of Maintenance of Road from MDR-21 Kanadwadi to Daranewadi, Wadachiwadi Road, KM :- 0/000 to 2/000, Taluka - Igatpuri, District - Nashik.

-

-

-

... More
Site Clearance, Dismantling and Earth Works

-

-

-

... More
Clearing and Grubbing Road Land Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means In area of non-thorny jungle Technical Specification MoRD 2014 Clause 201.

0.3

-

-

... More
Clearing and Grubbing Road Land Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means In area of thorny jungle Technical Specification MoRD 2014 Clause 201.

0.3

-

-

... More
Excavation in Soil using Hydraulic Excavator and Tippers with disposal More than 100 m Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with a lift upto 1.5 m and lead More than 100 m Excavation in Soil using Hydraulic Excavator and Tippers with disposal More than 100 m Technical Specification MoRD 2014 Clause 302.3.

1006.1

-

-

... More
Excavation in Ordinary Rock using Hydraulic Excavator and Tippers with disposal More than 100 m Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, transporting to embankment site with a lift upto 1.5 m and lead More than 100 m, trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections. Technical Specification MoRD 2014 Clause 302.3.5

118.37

-

-

... More
Excavation in Hard Rock (requiring blasting) with disposal More than 100 m Excavation for roadway in hard rock (requiring blasting) by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross-sections, loading and disposal of cut rock with a lift upto 1.5 m and leads More than 100 m. Technical Specification MoRD 2014 Clause 302.3.5

59.18

-

-

... More
Construction of Embankment with Material Obtained from Roadway Cutting Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2. Technical Specification MoRD 2014 Tables 300.1 and 300.2 Clause 301.5.

730.91

-

-

... More
Construction of Embankment with Material Obtained from Borrow Pits Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2. For lead upto 250 m Technical Specification MoRD 2014 Tables 300.1 and 300.2 Clause 301.5.

4154.23

-

-

... More
Pavement Works (GSB, WBM, Bituminous Works) and Cement Concrete Pavement Work

-

-

-

... More
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per Technical Specification Clause 401. By Using Crushed Aggregate.

856.12

-

-

... More
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per Technical Specification Clause 401. By Using Crushed Aggregate.

1146.26

-

-

... More
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per Technical Specification Clause 401. By Using Crushed Aggregate.

312

-

-

... More
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per Technical Specification Clause 401. By Using Crushed Aggregate.

4005.2

-

-

... More
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per Technical Specification Clause 401. By Using Crushed Aggregate.

4965.2

-

-

... More
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per Technical Specification Clause 401. By Using Crushed Aggregate.

4005.2

-

-

... More
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per Technical Specification Clause 401. By Using Crushed Aggregate.

4005.2

-

-

... More
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per Technical Specification Clause 401. By Using Crushed Aggregate.

486

-

-

... More
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per Technical Specification Clause 401. By Using Crushed Aggregate.

337.5

-

-

... More
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per Technical Specification Clause 401. By Using Crushed Aggregate.

156

-

-

... More
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per Technical Specification Clause 401. By Using Crushed Aggregate.

2000

-

-

... More
Cross Drainage Structures (Culverts & Minor Bridges), Drains and Protection Works

-

-

-

... More
Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary soil Upto 3 m depth By Mannual means As per MORD - 2014 Specification clause No. 305

179.5

-

-

... More
Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary rock (not requiring blasting) Upto 3 m depth As per MORD - 2014 Specification clause No. 305

83.94

-

-

... More
Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Hard rock (requiring Prohibeted) Upto 3 m depth including 1.5 m depth in hard rock As per MORD - 2014 Specification clause No. 305

10.73

-

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications as per MORD - 2014 Clause 802, 803, 1202 & 1203 P.C.C grade M 10 Nominal mix 1:3:6

31.21

-

-

... More
Providing and Laying Reinforced Cement Concrete Pipe NP3 as per design Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets As per MORD Specification 2014 Clause No. 1100. 1000 mm dia

37.5

-

-

... More
Providing and Laying Reinforced Cement Concrete Pipe NP2 as per design Providing and laying reinforced cement concrete pipe NP2 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets As per MORD Specification 2014 Clause No. 1100. 300 mm dia NP-2 Pipe

105

-

-

... More
Providing and Laying Reinforced Cement Concrete Pipe NP3 as per design Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets As per MORD Specification 2014 Clause No.1100. 600 mm dia NP-3 Pipe

61

-

-

... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification MORD 2014 Clauses 614, 709 P.V.C. pipe 100 mm dia

17

-

-

... More
Pitching on slopes Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1302

12.96

-

-

... More
P. C. C. grade M - 15 Concrete Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204

89.5

-

-

... More
P. C. C. grade M - 15 ConcretePlain / reinforced cement concrete grade M-15 (Nominal Mix (1:2.5:5)

170.22

-

-

... More
Traffic Signs, Markings and Road Appurtenances, Road Safety & Road Furniture

-

-

-

... More
Kilometre Stone Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014, Clause 1703 Kilometre Stone (precast)

3

-

-

... More
Kilometre Stone Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014, Clause 1703 200 m Stone

8

-

-

... More
Providing Guard stone/ boundary stone Providing and fixing trap /granite/ quartzite/ gneiss/ guard stone/ indicator stones/ boundry stones of standard size & shape including fixing In ground and white washing complete Spec. No.: As per MORTH Specification Clause No. 807

331

-

-

... More
Citizen Information Board Providing and fixing a typical MMGSY Citizen information board as per specification provided on detailed drawing of NRRDA having frame size of 2500 x 1150 mm with 75 mm square or round steel tube for support fixed in a concrete block of 60 x 60 x 75 cm size. Information as provided in drawing of NRRDA shall be displayed on a CR/GI sheet of appropriate thickness and fixed at steel frame with 5 mm steel plate. All lettering and painting arrows border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and coloured as mentioned in detailed drawing. All sections of framed posts and steel tube shall be painted with primer and two coat of epoxy paint as per drawings. Rate As per RD and WC Deptt. No. CMGSY - 2007 / CR / 145 / Yojana - 9 Dt. 04 / 04 / 2007

1

-

-

... More
Providing and Fixing 'Logo' of MMGSY Project Providing and fixing of typical MMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 as per MORD - 2014

1

-

-

... More
Direction and Place Identification signs upto 0.9 sqm size board B. Semi-Reflective Traffic signs Direction and place indentification signs up to 0.9 sqm size board Providing and erecting direction and place identifications of semi reflective sign boards as per IRC:67 made of 2 mm thick M.S. Sheet duly stove enameled paint in white colour in front and grey colour on back with red reflective border of 70 mm width and required message, letters, figures with reflective engineering grade tape as per MORD specifications of required shade and colour. Supported and welded on 47 mm x 47mm of 12 SWG Square tube of 3050 mm height duly strengthened by 25 mm x 5 mm M/s flat iron on edges on back firmly fixed to the ground by means of properly designed foundations with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701 As per MORD - 2014

8.64

-

-

... More
Providing and fixing of retro- reflectorised informatory sign board rectangular/Square in shape having area less than 0.9 One Square Meterr made out of ____mm aluminum sheet bonded with white retro reflective sheeting of Class __ ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3, supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with two coats of grey stove enamel paint and supported on one no. mild steel angle iron post 75 mm x 75 mm x 6 mm, 3.5 mt long firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing The angle iron post shall be duly painted with one coat of epoxy primer and two coats of epoxy finish paints having alternate black and white bands of 25 cm width including GI fixures and transportation etc.complete.The nut bolts of board with angle iron post/supporting structure after fixing at site has to be electrically welded. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) sheeting shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier.

17.28

-

-

... More
Providing white and colour washing to road side trees Providing white and colour washing to road side trees in 2 coats in 2 bands of white and one red band at centre of 30 cm height each including preparing the surface, cost of material, conveying etc. complete.

40

-

-

... More
Metal Beam Crash Barrier -- Type - A, W : Metal Beam Crash Barrier (Providing and erecting a W metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810)""

150

-

-

... More
Supplying and Fixing of Cat's Eye Supplying and Fixing of Molded Shank Raised Pavement Markers / Cat's Eye made of polycarbonate and ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face and shall support a load of 16000 kg tested in accordance to ASTM D 4280 Type H and complying to Specifications of Category A of MORTH Circular No RW/NH/33023/10-97 DO III Dt 11.06. 1997. The height, width and length shall not exceed 50 mm, 100 mm and 102 +/- 2 mm and with minimum reflective area of 13 Sqcm on each side and the slope to the base shall be 35 +/- 5 degree. The strength of detachment of the integrated cylindrical shanks, (of diameter not less than 19 +/- 2 mm and height not less than 30+/- 2 mm) from the body is to be a minimum value of 500 Kg. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturer's recommendation and complete as directed by the engineer.The contractor shall submit a two year warranty for satisfactory field performance including stipulated retro-reflectance of the reflecting panel, to the Engineer.

240

-

-

... More
Road Marking with Thermoplastic Compound Road Marking with Hot Applied Thermoplastic Compound with Reflectorizing Glass Beads on Bituminous Surface- Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorizing glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.complete.

94.2

-

-

... More
Providing Vertical Delineator having wide angle cube corner micro prismatic non metallic reflective sheeting confirming to Type XI of ASTM D4956 -09 with White Color and Red Color combination and having minimum of retro reflective exposed area of 125 Sq CM on top slots and 35 Sq CM on bottom slots and no edges shall be exposed for tampering. This tubular delineator shall have a core and shell construction, shell shall be made of tough, high impact resistant, injection-molded, thermoplastic outer body and the inner core shall consist of powder coated or painted Mild steel of minimum thickness 1.0mm.and core-shell structure shall be of height not less than 800 mm above the ground and width not less than 80 mm. The metallic core of the delineator shall extend 300mm beyond the shell length from bottom for installing in the ground. The extended portion shall have slots to insert anchoring rods for enhancing the concrete grip. The logo of the manufacturer shall be embossed on either side of the body in the injection molding process. The engineering thermoplastic used for making the delineator body shall have minimum initial mechanical properties of 600J/m tested in accordance with ASTM D256 and shall retain at least 70% of these minimum initial values when subjected to accelerated weathering for 1000hrs as per ASTM G155 or UL 746C and as per IRC 79 specifications and including fixing the unit in M20 Grade Cement Concrete of Size 30x30x40 cm including excavation for pit.

48

-

-

... More
Providing and fixing Cautionary/Warning sign boards in Equilateral Triangle size of 600 mm made out of 1.5mm aluminum sheet bonded with white retro reflective sheeting of Class C ( Type XI Micro prismatic grade sheeting) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3 Supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with grey stove enamel paint and supported on one no. of M. S. angle iron post of size 65 mm X 65 mm X 6 mm, 3.45 m long, duly painted with with flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in M25 grade concrete block of size 60cm X 60cm X 75cm including transportation etc; complete. ClassC ( Type XI Micro prismatic grade sheeting) shall have 10 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier.

20

-

-

... More
Providing and fixing Mandatory/Regulatory sign boards in circular shape of 600 mm dia made out of 3mm aluminum composite material ( ACM) sheet bonded with white retro reflective sheeting of Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3 Supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with grey stove enamel paint and supported on one no. of M. S. angle iron post of size 65 mm X 65 mm X 6 mm, 3.45 m long, duly painted with with flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in M25 grade concrete block of size 60cm X 60cm X 75cm including transportation etc; complete. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier.

32

-

-

... More
Providing & fixing Hazard markers board Providing & fixing Hazard markers board in rectangular shape of size 0.30x0.90m made out of 16 guage (1.60mm) thick M.S.sheet with angle frame 25X25X5 mm for pannel ,black non reflective opaque back ground and yellow oblique engineering grade reflective bands & back side in gray stove enamal paint etc complete ,including one MS.angle iron post of 50mmx50mmx6mm 1.8 mtr long painted with synthetick enamel paint of black colour including in G.I.fixture etc & fixing the board in 1:2.5:3 (M-15 Grade) concrete block of size 45cm x45cmx60cm .including transportation etc . complete

44

-

-

... More
MMGSY / PMGSY Maintenance Information Board Providing and fixing of typical MMGSY / PMGSY Retro Reflective information board as per section 1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing.The ACP sheets of 3 mm thick, of 1500mmx900 mm size duly rivetted with MS angles of 25 x 25 x 5 mm thick M.S angle. Riveting of all the sheets over angle and flat iron frame will be done neatly to have plain surface on one side. The angle iron frame of the plate will be welded to two nos. 75mm x75mm (12 SWG) sheet tubes posts placed at 1125mm apart centre to centre. These two posts will be embeded in cement concrete M15 grade block of 600x600x750mm below ground level. The height of the bottom of the plate will be 775mm from normal ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications. All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.5 and as directed by Engineer-In-charge. . A warranty for 5 / 7 years for the Retro reflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor.

1

-

-

... More
Improvement and 5 Years of Maintenance of Road from NH-3 to Advan Pardevi Road, (ODR-177), (VR-152), KM :- 0/000 to 5/500, Taluka - Igatpuri, District - Nashik.

-

-

-

... More
Site Clearance, Dismantling and Earth Works

-

-

-

... More
Clearing and Grubbing Road Land Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means In area of non-thorny jungle Technical Specification MoRD 2014 Clause 201.

0.83

-

-

... More
Clearing and Grubbing Road Land Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means In area of thorny jungle Technical Specification MoRD 2014 Clause 201.

0.83

-

-

... More
Excavation in Soil using Hydraulic Excavator and Tippers with disposal More than 100 m Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with a lift upto 1.5 m and lead More than 100 m Excavation in Soil using Hydraulic Excavator and Tippers with disposal More than 100 m Technical Specification MoRD 2014 Clause 302.3.

820.46

-

-

... More
Excavation in Ordinary Rock using Hydraulic Excavator and Tippers with disposal More than 100 m Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, transporting to embankment site with a lift upto 1.5 m and lead More than 100 m, trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections. Technical Specification MoRD 2014 Clause 302.3.5

96.53

-

-

... More
Excavation in Hard Rock (requiring blasting) with disposal More than 100 m Excavation for roadway in hard rock (requiring blasting) by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross-sections, loading and disposal of cut rock with a lift upto 1.5 m and leads More than 100 m. Technical Specification MoRD 2014 Clause 302.3.5

48.26

-

-

... More
Construction of Embankment with Material Obtained from Roadway Cutting Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2. Technical Specification MoRD 2014 Tables 300.1 and 300.2 Clause 301.5.

596.04

-

-

... More
Construction of Embankment with Material Obtained from Borrow Pits Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2. For lead upto 250 m Technical Specification MoRD 2014 Tables 300.1 and 300.2 Clause 301.5.

11611.86

-

-

... More
Scarifying Existing Surface to a Depth of 150 mm by Mechanical Means Scarifying the existing road surface to a depth of 150 mm and Sectioning for required width, watering and compaction of Scarified material with roller including all leads and lifts as per Technical Specification Clause 301.4., 303.5.2.

18375

-

-

... More
Pavement Works (GSB, WBM, Bituminous Works) and Cement Concrete Pavement Work

-

-

-

... More
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per Technical Specification Clause 401. By Using Crushed Aggregate.

633.74

-

-

... More
Water Bound Macadam with Crushable Screenings WBM Grading 2 Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 2. By Manual Means Technical Specification MoRD 2014 Clause 405.

2403.24

-

-

... More
Construction of Subgrade and Earthen Shoulders. Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification MORD 2014, Clause 303.1.

1911

-

-

... More
Tack Coat Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared bituminous surface cleaned with Hydraulic broom. Technical Specification MoRD 2014 Clause 503

13135.68

-

-

... More
Modified Penetration Macadam Construction of penetration macadam over prepared base by providing a layer of compacted crushed coarse aggregate using chips spreader with alternate applications of bituminous binder and key aggregates and rolling with a three wheel 80-100 kN static roller to achieve the desired degree of compaction. 50 mm thick Bitumen (S-65) 60/70 - VG-30 Technical Specification MoRD 2004 Clause 506

14095.68

-

-

... More
20mm thick Open-Graded Premix Carpet using Bituminous (penetration grade/modified bitumen) Binder Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C. Case - II By Mechanical Means Bitumen (S-65) VG-30 using Waste Plastic Technical Specification MoRD 2014 Clause 506.

13135.68

-

-

... More
Seal Coat Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C By Mechanical Means Case - I : Type A Bitumen (S-65) VG-30 Technical Specification MoRD 2014 Clause 508.

13135.68

-

-

... More
Dry lean cement concrete Sub-base Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate ( natural sand/ VSI grade finely washed crushed sand) conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, , cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor /by suitable means as approved by Engineer-in- charge , compacting with vibratory roller, finishing, curing and including preparation of sub-grade surface if required etc. complete. with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete.

445.5

-

-

... More
Thin White Topping Providing and laying White Topping/Short Paneled Concrete as per IRC-SP 76-2015 (Existing surface preparation to be done if necessary either by milling or leveling course with DLC to correct surface profile and to be paid separately) with un reinforced M-40 grade Pavement Quality Concrete using Ordinary Portland Cement 43/53 Grade OR Portland Pozzolona Cement IS-1489 at 425kg/cum, coarse aggregate, fine aggregate(VSI) and Admixture confirming to IS 9130-1999 (R-2004) polymeric synthetic fiber as per ASTM (1116) such as polyester / polyethylene / polypropylene / Glass fiber at 1.20 kg/cum, mixed in batching and mixing plant or weigh batcher as per approved mix design to achieve minimum flexural strength or modulus of rupture of concrete 4.50 MPa at 28 days limiting maximum water cement ratio to 0.40, transported to site, laid with fixed form/ slip form paver finisher (preferably with slip form paver finisher), spread, vibrated, compacted and finished in a continuous operation to the lines and grades as per drawing, texture finishing of surface, spraying two layers of curing compound, curing with water sprayed on hessian cloth covered over concrete surface, groove cutting grid 1m x 1m or as directed by Engineer Incharge to a depth of 1/3 to 1/4 of the Thickness and of width 3-5 mm as per design including cost of all material, side form work, labour and machineries etc. complete as per specifications.(Excluding Dowel Bars and Tie Bars) (Crushed VSI Sand ) Including Polythene Sheet of 125 Micron.

787.5

-

-

... More
MS dowel Bars Providing and fixing in position 25mm dia anti corossive MS dowel Bars of requird Dia 60 cms. Long and at 30.00 cms C/C and Wherever derect include handing, straighting necessary cutting support by chairs with proper alignment with half length covert by polythin sheathing include cap etc.

221

-

-

... More
TMT FE 500 ,tie bars Providing and fixing in position anti corrossive TMT FE 500 ,tie bars of 12 mm dia 70 cms long and at 30.00cm C/C and Wherever directed inclueding handling neccesary cutting, handling support by assembly of TMT FE 500, chairs with proper alignment complete

2834

-

-

... More
Cross Drainage Structures (Culverts & Minor Bridges), Drains and Protection Works

-

-

-

... More
Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary soil Upto 3 m depth By Mannual means As per MORD - 2014 Specification clause No. 305

459.69

-

-

... More
Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary rock (not requiring blasting) Upto 3 m depth As per MORD - 2014 Specification clause No. 305

244.86

-

-

... More
Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Hard rock (requiring Prohibeted) Upto 3 m depth including 1.5 m depth in hard rock As per MORD - 2014 Specification clause No. 305

21.45

-

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications as per MORD - 2014 Clause 802, 803, 1202 & 1203 P.C.C grade M 10 Nominal mix 1:3:6

121.26

-

-

... More
Providing and Laying Reinforced Cement Concrete Pipe NP3 as per design Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets As per MORD Specification 2014 Clause No. 1100. 1000 mm dia

140

-

-

... More
Providing and Laying Reinforced Cement Concrete Pipe NP2 as per design Providing and laying reinforced cement concrete pipe NP2 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets As per MORD Specification 2014 Clause No. 1100. 300 mm dia NP-2 Pipe

105

-

-

... More
Providing and Laying Reinforced Cement Concrete Pipe NP3 as per design Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets As per MORD Specification 2014 Clause No.1100. 600 mm dia NP-3 Pipe

61

-

-

... More
Painting Two Coats on New Concrete Surfaces Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surfaces as per drawing and Technical Specification MORD 2014 Clause 1701

3.6

-

-

... More
Printing New Letters and Figures of any Shade Printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade as per drawings and Technical Specification MORD 2014 Clause 1701 English and Roman Hyphens, commas and the like not to be measured and paid for. Detail for 100 letters of 160 mm height, i.e., 1600 cm

320

-

-

... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification MORD 2014 Clauses 614, 709 P.V.C. pipe 100 mm dia

70

-

-

... More
Pitching on slopes Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1302

79.38

-

-

... More
P. C. C. grade M - 15 Concrete Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204

179

-

-

... More
P. C. C. grade M - 15 ConcretePlain / reinforced cement concrete grade M-15 (Nominal Mix (1:2.5:5)

482.56

-

-

... More
Traffic Signs, Markings and Road Appurtenances, Road Safety & Road Furniture

-

-

-

... More
Kilometre Stone Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014, Clause 1703 5th Kilometre Stone (precast)

1

-

-

... More
Kilometre Stone Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014, Clause 1703 Kilometre Stone (precast)

5

-

-

... More
Kilometre Stone Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014, Clause 1703 200 m Stone

22

-

-

... More
Providing Guard stone/ boundary stone Providing and fixing trap /granite/ quartzite/ gneiss/ guard stone/ indicator stones/ boundry stones of standard size & shape including fixing In ground and white washing complete Spec. No.: As per MORTH Specification Clause No. 807

578

-

-

... More
Citizen Information Board Providing and fixing a typical MMGSY Citizen information board as per specification provided on detailed drawing of NRRDA having frame size of 2500 x 1150 mm with 75 mm square or round steel tube for support fixed in a concrete block of 60 x 60 x 75 cm size. Information as provided in drawing of NRRDA shall be displayed on a CR/GI sheet of appropriate thickness and fixed at steel frame with 5 mm steel plate. All lettering and painting arrows border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and coloured as mentioned in detailed drawing. All sections of framed posts and steel tube shall be painted with primer and two coat of epoxy paint as per drawings. Rate As per RD and WC Deptt. No. CMGSY - 2007 / CR / 145 / Yojana - 9 Dt. 04 / 04 / 2007

1

-

-

... More
Providing and Fixing 'Logo' of MMGSY Project Providing and fixing of typical MMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 as per MORD - 2014

1

-

-

... More
Direction and Place Identification signs upto 0.9 sqm size board B. Semi-Reflective Traffic signs Direction and place indentification signs up to 0.9 sqm size board Providing and erecting direction and place identifications of semi reflective sign boards as per IRC:67 made of 2 mm thick M.S. Sheet duly stove enameled paint in white colour in front and grey colour on back with red reflective border of 70 mm width and required message, letters, figures with reflective engineering grade tape as per MORD specifications of required shade and colour. Supported and welded on 47 mm x 47mm of 12 SWG Square tube of 3050 mm height duly strengthened by 25 mm x 5 mm M/s flat iron on edges on back firmly fixed to the ground by means of properly designed foundations with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701 As per MORD - 2014

8.64

-

-

... More
Providing and fixing of retro- reflectorised informatory sign board rectangular/Square in shape having area less than 0.9 One Square Meterr made out of ____mm aluminum sheet bonded with white retro reflective sheeting of Class __ ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3, supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with two coats of grey stove enamel paint and supported on one no. mild steel angle iron post 75 mm x 75 mm x 6 mm, 3.5 mt long firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing The angle iron post shall be duly painted with one coat of epoxy primer and two coats of epoxy finish paints having alternate black and white bands of 25 cm width including GI fixures and transportation etc.complete.The nut bolts of board with angle iron post/supporting structure after fixing at site has to be electrically welded. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) sheeting shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier.

17.28

-

-

... More
Providing white and colour washing to road side trees Providing white and colour washing to road side trees in 2 coats in 2 bands of white and one red band at centre of 30 cm height each including preparing the surface, cost of material, conveying etc. complete.

40

-

-

... More
Metal Beam Crash Barrier -- Type - A, W : Metal Beam Crash Barrier (Providing and erecting a W metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810)""

150

-

-

... More
Supplying and Fixing of Cat's Eye Supplying and Fixing of Molded Shank Raised Pavement Markers / Cat's Eye made of polycarbonate and ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face and shall support a load of 16000 kg tested in accordance to ASTM D 4280 Type H and complying to Specifications of Category A of MORTH Circular No RW/NH/33023/10-97 DO III Dt 11.06. 1997. The height, width and length shall not exceed 50 mm, 100 mm and 102 +/- 2 mm and with minimum reflective area of 13 Sqcm on each side and the slope to the base shall be 35 +/- 5 degree. The strength of detachment of the integrated cylindrical shanks, (of diameter not less than 19 +/- 2 mm and height not less than 30+/- 2 mm) from the body is to be a minimum value of 500 Kg. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturer's recommendation and complete as directed by the engineer.The contractor shall submit a two year warranty for satisfactory field performance including stipulated retro-reflectance of the reflecting panel, to the Engineer.

240

-

-

... More
Road Marking with Thermoplastic Compound Road Marking with Hot Applied Thermoplastic Compound with Reflectorizing Glass Beads on Bituminous Surface- Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorizing glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.complete.

299.2

-

-

... More
Providing Vertical Delineator having wide angle cube corner micro prismatic non metallic reflective sheeting confirming to Type XI of ASTM D4956 -09 with White Color and Red Color combination and having minimum of retro reflective exposed area of 125 Sq CM on top slots and 35 Sq CM on bottom slots and no edges shall be exposed for tampering. This tubular delineator shall have a core and shell construction, shell shall be made of tough, high impact resistant, injection-molded, thermoplastic outer body and the inner core shall consist of powder coated or painted Mild steel of minimum thickness 1.0mm.and core-shell structure shall be of height not less than 800 mm above the ground and width not less than 80 mm. The metallic core of the delineator shall extend 300mm beyond the shell length from bottom for installing in the ground. The extended portion shall have slots to insert anchoring rods for enhancing the concrete grip. The logo of the manufacturer shall be embossed on either side of the body in the injection molding process. The engineering thermoplastic used for making the delineator body shall have minimum initial mechanical properties of 600J/m tested in accordance with ASTM D256 and shall retain at least 70% of these minimum initial values when subjected to accelerated weathering for 1000hrs as per ASTM G155 or UL 746C and as per IRC 79 specifications and including fixing the unit in M20 Grade Cement Concrete of Size 30x30x40 cm including excavation for pit.

92

-

-

... More
Providing and fixing Cautionary/Warning sign boards in Equilateral Triangle size of 600 mm made out of 1.5mm aluminum sheet bonded with white retro reflective sheeting of Class C ( Type XI Micro prismatic grade sheeting) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3 Supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with grey stove enamel paint and supported on one no. of M. S. angle iron post of size 65 mm X 65 mm X 6 mm, 3.45 m long, duly painted with with flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in M25 grade concrete block of size 60cm X 60cm X 75cm including transportation etc; complete. ClassC ( Type XI Micro prismatic grade sheeting) shall have 10 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier.

20

-

-

... More
Providing and fixing Mandatory/Regulatory sign boards in circular shape of 600 mm dia made out of 3mm aluminum composite material ( ACM) sheet bonded with white retro reflective sheeting of Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3 Supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with grey stove enamel paint and supported on one no. of M. S. angle iron post of size 65 mm X 65 mm X 6 mm, 3.45 m long, duly painted with with flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in M25 grade concrete block of size 60cm X 60cm X 75cm including transportation etc; complete. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier.

32

-

-

... More
MMGSY / PMGSY Maintenance Information Board Providing and fixing of typical MMGSY / PMGSY Retro Reflective information board as per section 1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing.The ACP sheets of 3 mm thick, of 1500mmx900 mm size duly rivetted with MS angles of 25 x 25 x 5 mm thick M.S angle. Riveting of all the sheets over angle and flat iron frame will be done neatly to have plain surface on one side. The angle iron frame of the plate will be welded to two nos. 75mm x75mm (12 SWG) sheet tubes posts placed at 1125mm apart centre to centre. These two posts will be embeded in cement concrete M15 grade block of 600x600x750mm below ground level. The height of the bottom of the plate will be 775mm from normal ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications. All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.5 and as directed by Engineer-In-charge. . A warranty for 5 / 7 years for the Retro reflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor.

1

-

-

... More
Providing & fixing Hazard markers board Providing & fixing Hazard markers board in rectangular shape of size 0.30x0.90m made out of 16 guage (1.60mm) thick M.S.sheet with angle frame 25X25X5 mm for pannel ,black non reflective opaque back ground and yellow oblique engineering grade reflective bands & back side in gray stove enamal paint etc complete ,including one MS.angle iron post of 50mmx50mmx6mm 1.8 mtr long painted with synthetick enamel paint of black colour including in G.I.fixture etc & fixing the board in 1:2.5:3 (M-15 Grade) concrete block of size 45cm x45cmx60cm .including transportation etc . complete

88

-

-

... More
Improvement and 5 Years of Maintenance of Road from MDR-20 Sanjegaon, Modale, Shirsathe, Kushegaon Road, (TR-18) KM :- 0/000 to 3/500, Branch - KM :- 0/000 to 1/000, Taluka - Igatpuri, District - Nashik.

-

-

-

... More
Site Clearance, Dismantling and Earth Works

-

-

-

... More
Clearing and Grubbing Road Land Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means In area of non-thorny jungle Technical Specification MoRD 2014 Clause 201.

0.68

-

-

... More
Clearing and Grubbing Road Land Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means In area of thorny jungle Technical Specification MoRD 2014 Clause 201.

0.68

-

-

... More
Excavation in Soil using Hydraulic Excavator and Tippers with disposal More than 100 m Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with a lift upto 1.5 m and lead More than 100 m Excavation in Soil using Hydraulic Excavator and Tippers with disposal More than 100 m Technical Specification MoRD 2014 Clause 302.3.

3692.91

-

-

... More
Excavation in Ordinary Rock using Hydraulic Excavator and Tippers with disposal More than 100 m Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, transporting to embankment site with a lift upto 1.5 m and lead More than 100 m, trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections. Technical Specification MoRD 2014 Clause 302.3.5

434.46

-

-

... More
Excavation in Hard Rock (requiring blasting) with disposal More than 100 m Excavation for roadway in hard rock (requiring blasting) by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross-sections, loading and disposal of cut rock with a lift upto 1.5 m and leads More than 100 m. Technical Specification MoRD 2014 Clause 302.3.5

217.23

-

-

... More
Construction of Embankment with Material Obtained from Roadway Cutting Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2. Technical Specification MoRD 2014 Tables 300.1 and 300.2 Clause 301.5.

2682.79

-

-

... More
Construction of Embankment with Material Obtained from Borrow Pits Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2. For lead upto 250 m Technical Specification MoRD 2014 Tables 300.1 and 300.2 Clause 301.5.

6375.89

-

-

... More
Scarifying Existing Surface to a Depth of 150 mm by Mechanical Means Scarifying the existing road surface to a depth of 150 mm and Sectioning for required width, watering and compaction of Scarified material with roller including all leads and lifts as per Technical Specification Clause 301.4., 303.5.2.

18000

-

-

... More
Dismantling Stone Masonry. Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m. Rubble Stone Masonry in Cement Mortar Technical Specification MoRD 2014 Clause 202.

33.33

-

-

... More
Removing all types of Hume pipes and stacking within a lead of 1000 m including Earthwork and Dismantling of Masonry Works. Above 600 mm to 900 mm dia Hume pipe Technical Specification MoRD 2014 Clause 202.

22.5

-

-

... More
Pavement Works (GSB, WBM, Bituminous Works) and Cement Concrete Pavement Work

-

-

-

... More
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per Technical Specification Clause 401. By Using Crushed Aggregate.

1822.43

-

-

... More
Water Bound Macadam with Crushable Screenings WBM Grading 2 Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 2. By Manual Means Technical Specification MoRD 2014 Clause 405.

2544.99

-

-

... More
Construction of Subgrade and Earthen Shoulders. Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification MORD 2014, Clause 303.1.

1755

-

-

... More
Tack Coat Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared bituminous surface cleaned with Hydraulic broom. Technical Specification MoRD 2014 Clause 503

19684.9

-

-

... More
Modified Penetration Macadam Construction of penetration macadam over prepared base by providing a layer of compacted crushed coarse aggregate using chips spreader with alternate applications of bituminous binder and key aggregates and rolling with a three wheel 80-100 kN static roller to achieve the desired degree of compaction. 50 mm thick Bitumen (S-65) 60/70 - VG-30 Technical Specification MoRD 2004 Clause 506

19684.9

-

-

... More
20mm thick Open-Graded Premix Carpet using Bituminous (penetration grade/modified bitumen) Binder Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C. Case - II By Mechanical Means Bitumen (S-65) VG-30 using Waste Plastic Technical Specification MoRD 2014 Clause 506.

19684.9

-

-

... More
Seal Coat Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C By Mechanical Means Case - I : Type A Bitumen (S-65) VG-30 Technical Specification MoRD 2014 Clause 508.

19684.9

-

-

... More
Dry lean cement concrete Sub-base Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate ( natural sand/ VSI grade finely washed crushed sand) conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, , cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor /by suitable means as approved by Engineer-in- charge , compacting with vibratory roller, finishing, curing and including preparation of sub-grade surface if required etc. complete. with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete.

202.5

-

-

... More
Thin White Topping Providing and laying White Topping/Short Paneled Concrete as per IRC-SP 76-2015 (Existing surface preparation to be done if necessary either by milling or leveling course with DLC to correct surface profile and to be paid separately) with un reinforced M-40 grade Pavement Quality Concrete using Ordinary Portland Cement 43/53 Grade OR Portland Pozzolona Cement IS-1489 at 425kg/cum, coarse aggregate, fine aggregate(VSI) and Admixture confirming to IS 9130-1999 (R-2004) polymeric synthetic fiber as per ASTM (1116) such as polyester / polyethylene / polypropylene / Glass fiber at 1.20 kg/cum, mixed in batching and mixing plant or weigh batcher as per approved mix design to achieve minimum flexural strength or modulus of rupture of concrete 4.50 MPa at 28 days limiting maximum water cement ratio to 0.40, transported to site, laid with fixed form/ slip form paver finisher (preferably with slip form paver finisher), spread, vibrated, compacted and finished in a continuous operation to the lines and grades as per drawing, texture finishing of surface, spraying two layers of curing compound, curing with water sprayed on hessian cloth covered over concrete surface, groove cutting grid 1m x 1m or as directed by Engineer Incharge to a depth of 1/3 to 1/4 of the Thickness and of width 3-5 mm as per design including cost of all material, side form work, labour and machineries etc. complete as per specifications.(Excluding Dowel Bars and Tie Bars) (Crushed VSI Sand ) Including Polythene Sheet of 125 Micron.

281.25

-

-

... More
MS dowel Bars Providing and fixing in position 25mm dia anti corossive MS dowel Bars of requird Dia 60 cms. Long and at 30.00 cms C/C and Wherever derect include handing, straighting necessary cutting support by chairs with proper alignment with half length covert by polythin sheathing include cap etc.

65

-

-

... More
TMT FE 500 ,tie bars Providing and fixing in position anti corrossive TMT FE 500 ,tie bars of 12 mm dia 70 cms long and at 30.00cm C/C and Wherever directed inclueding handling neccesary cutting, handling support by assembly of TMT FE 500, chairs with proper alignment complete

834

-

-

... More
Cross Drainage Structures (Culverts & Minor Bridges), Drains and Protection Works

-

-

-

... More
Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary soil Upto 3 m depth By Mannual means As per MORD - 2014 Specification clause No. 305

252.98

-

-

... More
Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary rock (not requiring blasting) Upto 3 m depth As per MORD - 2014 Specification clause No. 305

128.22

-

-

... More
Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Hard rock (requiring Prohibeted) Upto 3 m depth including 1.5 m depth in hard rock As per MORD - 2014 Specification clause No. 305

10.73

-

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications as per MORD - 2014 Clause 802, 803, 1202 & 1203 P.C.C grade M 10 Nominal mix 1:3:6

42.27

-

-

... More
Providing and Laying Reinforced Cement Concrete Pipe NP3 as per design Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets As per MORD Specification 2014 Clause No. 1100. 1000 mm dia

67.5

-

-

... More
Providing and Laying Reinforced Cement Concrete Pipe NP2 as per design Providing and laying reinforced cement concrete pipe NP2 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets As per MORD Specification 2014 Clause No. 1100. 300 mm dia NP-2 Pipe

105

-

-

... More
Providing and Laying Reinforced Cement Concrete Pipe NP3 as per design Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets As per MORD Specification 2014 Clause No.1100. 600 mm dia NP-3 Pipe

65

-

-

... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification MORD 2014 Clauses 614, 709 P.V.C. pipe 100 mm dia

17

-

-

... More
Providing and fixing in position pipe railing consisting of IS Rolled steel joist posts designation IS MB 100 (100x75) at 2.5 m interval and three rows of 50 mm dia steel pipes (light) including fixing in position on bridge deck complete as per drawing and technical specifications MORD 2014 Clause 1404.3.5.1

80

-

-

... More
Pitching on slopes Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1302

85.05

-

-

... More
P. C. C. grade M - 15 Concrete Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204

89.5

-

-

... More
P. C. C. grade M - 15 ConcretePlain / reinforced cement concrete grade M-15 (Nominal Mix (1:2.5:5)

282.66

-

-

... More
Traffic Signs, Markings and Road Appurtenances, Road Safety & Road Furniture

-

-

-

... More
Kilometre Stone Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014, Clause 1703 Kilometre Stone (precast)

5

-

-

... More
Kilometre Stone Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014, Clause 1703 200 m Stone

18

-

-

... More
Providing Guard stone/ boundary stone Providing and fixing trap /granite/ quartzite/ gneiss/ guard stone/ indicator stones/ boundry stones of standard size & shape including fixing In ground and white washing complete Spec. No.: As per MORTH Specification Clause No. 807

506

-

-

... More
Citizen Information Board Providing and fixing a typical MMGSY Citizen information board as per specification provided on detailed drawing of NRRDA having frame size of 2500 x 1150 mm with 75 mm square or round steel tube for support fixed in a concrete block of 60 x 60 x 75 cm size. Information as provided in drawing of NRRDA shall be displayed on a CR/GI sheet of appropriate thickness and fixed at steel frame with 5 mm steel plate. All lettering and painting arrows border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and coloured as mentioned in detailed drawing. All sections of framed posts and steel tube shall be painted with primer and two coat of epoxy paint as per drawings. Rate As per RD and WC Deptt. No. CMGSY - 2007 / CR / 145 / Yojana - 9 Dt. 04 / 04 / 2007

1

-

-

... More
Providing and Fixing 'Logo' of MMGSY Project Providing and fixing of typical MMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 as per MORD - 2014

1

-

-

... More
Direction and Place Identification signs upto 0.9 sqm size board B. Semi-Reflective Traffic signs Direction and place indentification signs up to 0.9 sqm size board Providing and erecting direction and place identifications of semi reflective sign boards as per IRC:67 made of 2 mm thick M.S. Sheet duly stove enameled paint in white colour in front and grey colour on back with red reflective border of 70 mm width and required message, letters, figures with reflective engineering grade tape as per MORD specifications of required shade and colour. Supported and welded on 47 mm x 47mm of 12 SWG Square tube of 3050 mm height duly strengthened by 25 mm x 5 mm M/s flat iron on edges on back firmly fixed to the ground by means of properly designed foundations with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701 As per MORD - 2014

25.92

-

-

... More
Providing and fixing of retro- reflectorised informatory sign board rectangular/Square in shape having area less than 0.9 One Square Meterr made out of ____mm aluminum sheet bonded with white retro reflective sheeting of Class __ ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3, supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with two coats of grey stove enamel paint and supported on one no. mild steel angle iron post 75 mm x 75 mm x 6 mm, 3.5 mt long firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing The angle iron post shall be duly painted with one coat of epoxy primer and two coats of epoxy finish paints having alternate black and white bands of 25 cm width including GI fixures and transportation etc.complete.The nut bolts of board with angle iron post/supporting structure after fixing at site has to be electrically welded. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) sheeting shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier.

32.4

-

-

... More
Providing white and colour washing to road side trees Providing white and colour washing to road side trees in 2 coats in 2 bands of white and one red band at centre of 30 cm height each including preparing the surface, cost of material, conveying etc. complete.

40

-

-

... More
Metal Beam Crash Barrier -- Type - A, W : Metal Beam Crash Barrier (Providing and erecting a W metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810)""

120

-

-

... More
Supplying and Fixing of Cat's Eye Supplying and Fixing of Molded Shank Raised Pavement Markers / Cat's Eye made of polycarbonate and ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face and shall support a load of 16000 kg tested in accordance to ASTM D 4280 Type H and complying to Specifications of Category A of MORTH Circular No RW/NH/33023/10-97 DO III Dt 11.06. 1997. The height, width and length shall not exceed 50 mm, 100 mm and 102 +/- 2 mm and with minimum reflective area of 13 Sqcm on each side and the slope to the base shall be 35 +/- 5 degree. The strength of detachment of the integrated cylindrical shanks, (of diameter not less than 19 +/- 2 mm and height not less than 30+/- 2 mm) from the body is to be a minimum value of 500 Kg. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturer's recommendation and complete as directed by the engineer.The contractor shall submit a two year warranty for satisfactory field performance including stipulated retro-reflectance of the reflecting panel, to the Engineer.

240

-

-

... More
Road Marking with Thermoplastic Compound Road Marking with Hot Applied Thermoplastic Compound with Reflectorizing Glass Beads on Bituminous Surface- Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorizing glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.complete.

113.2

-

-

... More
Providing Vertical Delineator having wide angle cube corner micro prismatic non metallic reflective sheeting confirming to Type XI of ASTM D4956 -09 with White Color and Red Color combination and having minimum of retro reflective exposed area of 125 Sq CM on top slots and 35 Sq CM on bottom slots and no edges shall be exposed for tampering. This tubular delineator shall have a core and shell construction, shell shall be made of tough, high impact resistant, injection-molded, thermoplastic outer body and the inner core shall consist of powder coated or painted Mild steel of minimum thickness 1.0mm.and core-shell structure shall be of height not less than 800 mm above the ground and width not less than 80 mm. The metallic core of the delineator shall extend 300mm beyond the shell length from bottom for installing in the ground. The extended portion shall have slots to insert anchoring rods for enhancing the concrete grip. The logo of the manufacturer shall be embossed on either side of the body in the injection molding process. The engineering thermoplastic used for making the delineator body shall have minimum initial mechanical properties of 600J/m tested in accordance with ASTM D256 and shall retain at least 70% of these minimum initial values when subjected to accelerated weathering for 1000hrs as per ASTM G155 or UL 746C and as per IRC 79 specifications and including fixing the unit in M20 Grade Cement Concrete of Size 30x30x40 cm including excavation for pit.

72

-

-

... More
Providing and fixing Cautionary/Warning sign boards in Equilateral Triangle size of 600 mm made out of 1.5mm aluminum sheet bonded with white retro reflective sheeting of Class C ( Type XI Micro prismatic grade sheeting) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3 Supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with grey stove enamel paint and supported on one no. of M. S. angle iron post of size 65 mm X 65 mm X 6 mm, 3.45 m long, duly painted with with flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in M25 grade concrete block of size 60cm X 60cm X 75cm including transportation etc; complete. ClassC ( Type XI Micro prismatic grade sheeting) shall have 10 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier.

20

-

-

... More
Providing and fixing Mandatory/Regulatory sign boards in circular shape of 600 mm dia made out of 3mm aluminum composite material ( ACM) sheet bonded with white retro reflective sheeting of Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3 Supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with grey stove enamel paint and supported on one no. of M. S. angle iron post of size 65 mm X 65 mm X 6 mm, 3.45 m long, duly painted with with flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in M25 grade concrete block of size 60cm X 60cm X 75cm including transportation etc; complete. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier.

32

-

-

... More
MMGSY / PMGSY Maintenance Information Board Providing and fixing of typical MMGSY / PMGSY Retro Reflective information board as per section 1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing.The ACP sheets of 3 mm thick, of 1500mmx900 mm size duly rivetted with MS angles of 25 x 25 x 5 mm thick M.S angle. Riveting of all the sheets over angle and flat iron frame will be done neatly to have plain surface on one side. The angle iron frame of the plate will be welded to two nos. 75mm x75mm (12 SWG) sheet tubes posts placed at 1125mm apart centre to centre. These two posts will be embeded in cement concrete M15 grade block of 600x600x750mm below ground level. The height of the bottom of the plate will be 775mm from normal ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications. All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.5 and as directed by Engineer-In-charge. . A warranty for 5 / 7 years for the Retro reflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor.

1

-

-

... More
Providing & fixing Hazard markers board Providing & fixing Hazard markers board in rectangular shape of size 0.30x0.90m made out of 16 guage (1.60mm) thick M.S.sheet with angle frame 25X25X5 mm for pannel ,black non reflective opaque back ground and yellow oblique engineering grade reflective bands & back side in gray stove enamal paint etc complete ,including one MS.angle iron post of 50mmx50mmx6mm 1.8 mtr long painted with synthetick enamel paint of black colour including in G.I.fixture etc & fixing the board in 1:2.5:3 (M-15 Grade) concrete block of size 45cm x45cmx60cm .including transportation etc . complete

60

-

-

... More
Improvement and 5 Years of Maintenance of Road from Ghoti Kh. , Rongtewadi to Kawadadara Road, (TR-03), (ODR-99), (VR-11), KM :- 0/000 to 7/000, Taluka - Igatpuri, District - Nashik.

-

-

-

... More
Site Clearance, Dismantling and Earth Works

-

-

-

... More
Clearing and Grubbing Road Land Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means In area of non-thorny jungle Technical Specification MoRD 2014 Clause 201.

1.05

-

-

... More
Clearing and Grubbing Road Land Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means In area of thorny jungle Technical Specification MoRD 2014 Clause 201.

1.05

-

-

... More
Excavation in Soil using Hydraulic Excavator and Tippers with disposal More than 100 m Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with a lift upto 1.5 m and lead More than 100 m Excavation in Soil using Hydraulic Excavator and Tippers with disposal More than 100 m Technical Specification MoRD 2014 Clause 302.3.

5930.54

-

-

... More
Excavation in Ordinary Rock using Hydraulic Excavator and Tippers with disposal More than 100 m Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, transporting to embankment site with a lift upto 1.5 m and lead More than 100 m, trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections. Technical Specification MoRD 2014 Clause 302.3.5

697.71

-

-

... More
Excavation in Hard Rock (requiring blasting) with disposal More than 100 m Excavation for roadway in hard rock (requiring blasting) by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross-sections, loading and disposal of cut rock with a lift upto 1.5 m and leads More than 100 m. Technical Specification MoRD 2014 Clause 302.3.5

348.86

-

-

... More
Construction of Embankment with Material Obtained from Roadway Cutting Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2. Technical Specification MoRD 2014 Tables 300.1 and 300.2 Clause 301.5.

4308.36

-

-

... More
Construction of Embankment with Material Obtained from Borrow Pits Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2. For lead upto 250 m Technical Specification MoRD 2014 Tables 300.1 and 300.2 Clause 301.5.

9474.16

-

-

... More
Scarifying Existing Surface to a Depth of 150 mm by Mechanical Means Scarifying the existing road surface to a depth of 150 mm and Sectioning for required width, watering and compaction of Scarified material with roller including all leads and lifts as per Technical Specification Clause 301.4., 303.5.2.

21000

-

-

... More
Dismantling Stone Masonry. Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m. Rubble Stone Masonry in Cement Mortar Technical Specification MoRD 2014 Clause 202.

33.33

-

-

... More
Removing all types of Hume pipes and stacking within a lead of 1000 m including Earthwork and Dismantling of Masonry Works. Above 600 mm to 900 mm dia Hume pipe Technical Specification MoRD 2014 Clause 202.

22.5

-

-

... More
Pavement Works (GSB, WBM, Bituminous Works) and Cement Concrete Pavement Work

-

-

-

... More
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per Technical Specification Clause 401. By Using Crushed Aggregate.

4475.28

-

-

... More
Water Bound Macadam with Crushable Screenings WBM Grading 2 Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 2. By Manual Means Technical Specification MoRD 2014 Clause 405.

3845.6

-

-

... More
Construction of Subgrade and Earthen Shoulders. Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification MORD 2014, Clause 303.1.

2730

-

-

... More
Tack Coat Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared bituminous surface cleaned with Hydraulic broom. Technical Specification MoRD 2014 Clause 503

24197.34

-

-

... More
Modified Penetration Macadam Construction of penetration macadam over prepared base by providing a layer of compacted crushed coarse aggregate using chips spreader with alternate applications of bituminous binder and key aggregates and rolling with a three wheel 80-100 kN static roller to achieve the desired degree of compaction. 50 mm thick Bitumen (S-65) 60/70 - VG-30 Technical Specification MoRD 2004 Clause 506

24197.34

-

-

... More
20mm thick Open-Graded Premix Carpet using Bituminous (penetration grade/modified bitumen) Binder Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C. Case - II By Mechanical Means Bitumen (S-65) VG-30 using Waste Plastic Technical Specification MoRD 2014 Clause 506.

24197.34

-

-

... More
Seal Coat Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C By Mechanical Means Case - I : Type A Bitumen (S-65) VG-30 Technical Specification MoRD 2014 Clause 508.

24197.34

-

-

... More
Dry lean cement concrete Sub-base Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate ( natural sand/ VSI grade finely washed crushed sand) conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, , cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor /by suitable means as approved by Engineer-in- charge , compacting with vibratory roller, finishing, curing and including preparation of sub-grade surface if required etc. complete. with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete.

405

-

-

... More
Thin White Topping Providing and laying White Topping/Short Paneled Concrete as per IRC-SP 76-2015 (Existing surface preparation to be done if necessary either by milling or leveling course with DLC to correct surface profile and to be paid separately) with un reinforced M-40 grade Pavement Quality Concrete using Ordinary Portland Cement 43/53 Grade OR Portland Pozzolona Cement IS-1489 at 425kg/cum, coarse aggregate, fine aggregate(VSI) and Admixture confirming to IS 9130-1999 (R-2004) polymeric synthetic fiber as per ASTM (1116) such as polyester / polyethylene / polypropylene / Glass fiber at 1.20 kg/cum, mixed in batching and mixing plant or weigh batcher as per approved mix design to achieve minimum flexural strength or modulus of rupture of concrete 4.50 MPa at 28 days limiting maximum water cement ratio to 0.40, transported to site, laid with fixed form/ slip form paver finisher (preferably with slip form paver finisher), spread, vibrated, compacted and finished in a continuous operation to the lines and grades as per drawing, texture finishing of surface, spraying two layers of curing compound, curing with water sprayed on hessian cloth covered over concrete surface, groove cutting grid 1m x 1m or as directed by Engineer Incharge to a depth of 1/3 to 1/4 of the Thickness and of width 3-5 mm as per design including cost of all material, side form work, labour and machineries etc. complete as per specifications.(Excluding Dowel Bars and Tie Bars) (Crushed VSI Sand ) Including Polythene Sheet of 125 Micron.

562.5

-

-

... More
MS dowel Bars Providing and fixing in position 25mm dia anti corossive MS dowel Bars of requird Dia 60 cms. Long and at 30.00 cms C/C and Wherever derect include handing, straighting necessary cutting support by chairs with proper alignment with half length covert by polythin sheathing include cap etc.

299

-

-

... More
TMT FE 500 ,tie bars Providing and fixing in position anti corrossive TMT FE 500 ,tie bars of 12 mm dia 70 cms long and at 30.00cm C/C and Wherever directed inclueding handling neccesary cutting, handling support by assembly of TMT FE 500, chairs with proper alignment complete

3834

-

-

... More
Cross Drainage Structures (Culverts & Minor Bridges), Drains and Protection Works

-

-

-

... More
Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary soil Upto 3 m depth By Mannual means As per MORD - 2014 Specification clause No. 305

412.02

-

-

... More
Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary rock (not requiring blasting) Upto 3 m depth As per MORD - 2014 Specification clause No. 305

206.38

-

-

... More
Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Hard rock (requiring Prohibeted) Upto 3 m depth including 1.5 m depth in hard rock As per MORD - 2014 Specification clause No. 305

21.45

-

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications as per MORD - 2014 Clause 802, 803, 1202 & 1203 P.C.C grade M 10 Nominal mix 1:3:6

92.11

-

-

... More
Providing and Laying Reinforced Cement Concrete Pipe NP3 as per design Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets As per MORD Specification 2014 Clause No. 1100. 1000 mm dia

107.5

-

-

... More
Providing and Laying Reinforced Cement Concrete Pipe NP2 as per design Providing and laying reinforced cement concrete pipe NP2 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets As per MORD Specification 2014 Clause No. 1100. 300 mm dia NP-2 Pipe

165

-

-

... More
Providing and Laying Reinforced Cement Concrete Pipe NP3 as per design Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets As per MORD Specification 2014 Clause No.1100. 600 mm dia NP-3 Pipe

105

-

-

... More
Painting Two Coats on New Concrete Surfaces Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surfaces as per drawing and Technical Specification MORD 2014 Clause 1701

1.8

-

-

... More
Printing New Letters and Figures of any Shade Printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade as per drawings and Technical Specification MORD 2014 Clause 1701 English and Roman Hyphens, commas and the like not to be measured and paid for. Detail for 100 letters of 160 mm height, i.e., 1600 cm

160

-

-

... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification MORD 2014 Clauses 614, 709 P.V.C. pipe 100 mm dia

70

-

-

... More
Pitching on slopes Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1302

132.3

-

-

... More
P. C. C. grade M - 15 Concrete Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204

179

-

-

... More
P. C. C. grade M - 15 ConcretePlain / reinforced cement concrete grade M-15 (Nominal Mix (1:2.5:5)

391.87

-

-

... More
Traffic Signs, Markings and Road Appurtenances, Road Safety & Road Furniture

-

-

-

... More
Kilometre Stone Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014, Clause 1703 5th Kilometre Stone (precast)

1

-

-

... More
Kilometre Stone Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014, Clause 1703 Kilometre Stone (precast)

7

-

-

... More
Kilometre Stone Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014, Clause 1703 200 m Stone

28

-

-

... More
Providing Guard stone/ boundary stone Providing and fixing trap /granite/ quartzite/ gneiss/ guard stone/ indicator stones/ boundry stones of standard size & shape including fixing In ground and white washing complete Spec. No.: As per MORTH Specification Clause No. 807

670

-

-

... More
Citizen Information Board Providing and fixing a typical MMGSY Citizen information board as per specification provided on detailed drawing of NRRDA having frame size of 2500 x 1150 mm with 75 mm square or round steel tube for support fixed in a concrete block of 60 x 60 x 75 cm size. Information as provided in drawing of NRRDA shall be displayed on a CR/GI sheet of appropriate thickness and fixed at steel frame with 5 mm steel plate. All lettering and painting arrows border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and coloured as mentioned in detailed drawing. All sections of framed posts and steel tube shall be painted with primer and two coat of epoxy paint as per drawings. Rate As per RD and WC Deptt. No. CMGSY - 2007 / CR / 145 / Yojana - 9 Dt. 04 / 04 / 2007

1

-

-

... More
Providing and Fixing 'Logo' of MMGSY Project Providing and fixing of typical MMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 as per MORD - 2014

1

-

-

... More
Direction and Place Identification signs upto 0.9 sqm size board B. Semi-Reflective Traffic signs Direction and place indentification signs up to 0.9 sqm size board Providing and erecting direction and place identifications of semi reflective sign boards as per IRC:67 made of 2 mm thick M.S. Sheet duly stove enameled paint in white colour in front and grey colour on back with red reflective border of 70 mm width and required message, letters, figures with reflective engineering grade tape as per MORD specifications of required shade and colour. Supported and welded on 47 mm x 47mm of 12 SWG Square tube of 3050 mm height duly strengthened by 25 mm x 5 mm M/s flat iron on edges on back firmly fixed to the ground by means of properly designed foundations with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701 As per MORD - 2014

25.92

-

-

... More
Providing and fixing of retro- reflectorised informatory sign board rectangular/Square in shape having area less than 0.9 One Square Meterr made out of ____mm aluminum sheet bonded with white retro reflective sheeting of Class __ ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3, supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with two coats of grey stove enamel paint and supported on one no. mild steel angle iron post 75 mm x 75 mm x 6 mm, 3.5 mt long firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing The angle iron post shall be duly painted with one coat of epoxy primer and two coats of epoxy finish paints having alternate black and white bands of 25 cm width including GI fixures and transportation etc.complete.The nut bolts of board with angle iron post/supporting structure after fixing at site has to be electrically welded. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) sheeting shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier.

32.4

-

-

... More
Providing white and colour washing to road side trees Providing white and colour washing to road side trees in 2 coats in 2 bands of white and one red band at centre of 30 cm height each including preparing the surface, cost of material, conveying etc. complete.

40

-

-

... More
Metal Beam Crash Barrier -- Type - A, W : Metal Beam Crash Barrier (Providing and erecting a W metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810)""

90

-

-

... More
Supplying and Fixing of Cat's Eye Supplying and Fixing of Molded Shank Raised Pavement Markers / Cat's Eye made of polycarbonate and ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face and shall support a load of 16000 kg tested in accordance to ASTM D 4280 Type H and complying to Specifications of Category A of MORTH Circular No RW/NH/33023/10-97 DO III Dt 11.06. 1997. The height, width and length shall not exceed 50 mm, 100 mm and 102 +/- 2 mm and with minimum reflective area of 13 Sqcm on each side and the slope to the base shall be 35 +/- 5 degree. The strength of detachment of the integrated cylindrical shanks, (of diameter not less than 19 +/- 2 mm and height not less than 30+/- 2 mm) from the body is to be a minimum value of 500 Kg. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturer's recommendation and complete as directed by the engineer.The contractor shall submit a two year warranty for satisfactory field performance including stipulated retro-reflectance of the reflecting panel, to the Engineer.

240

-

-

... More
Road Marking with Thermoplastic Compound Road Marking with Hot Applied Thermoplastic Compound with Reflectorizing Glass Beads on Bituminous Surface- Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorizing glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.complete.

278.2

-

-

... More
Providing Vertical Delineator having wide angle cube corner micro prismatic non metallic reflective sheeting confirming to Type XI of ASTM D4956 -09 with White Color and Red Color combination and having minimum of retro reflective exposed area of 125 Sq CM on top slots and 35 Sq CM on bottom slots and no edges shall be exposed for tampering. This tubular delineator shall have a core and shell construction, shell shall be made of tough, high impact resistant, injection-molded, thermoplastic outer body and the inner core shall consist of powder coated or painted Mild steel of minimum thickness 1.0mm.and core-shell structure shall be of height not less than 800 mm above the ground and width not less than 80 mm. The metallic core of the delineator shall extend 300mm beyond the shell length from bottom for installing in the ground. The extended portion shall have slots to insert anchoring rods for enhancing the concrete grip. The logo of the manufacturer shall be embossed on either side of the body in the injection molding process. The engineering thermoplastic used for making the delineator body shall have minimum initial mechanical properties of 600J/m tested in accordance with ASTM D256 and shall retain at least 70% of these minimum initial values when subjected to accelerated weathering for 1000hrs as per ASTM G155 or UL 746C and as per IRC 79 specifications and including fixing the unit in M20 Grade Cement Concrete of Size 30x30x40 cm including excavation for pit.

88

-

-

... More
Providing and fixing Cautionary/Warning sign boards in Equilateral Triangle size of 600 mm made out of 1.5mm aluminum sheet bonded with white retro reflective sheeting of Class C ( Type XI Micro prismatic grade sheeting) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3 Supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with grey stove enamel paint and supported on one no. of M. S. angle iron post of size 65 mm X 65 mm X 6 mm, 3.45 m long, duly painted with with flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in M25 grade concrete block of size 60cm X 60cm X 75cm including transportation etc; complete. ClassC ( Type XI Micro prismatic grade sheeting) shall have 10 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier.

20

-

-

... More
Providing and fixing Mandatory/Regulatory sign boards in circular shape of 600 mm dia made out of 3mm aluminum composite material ( ACM) sheet bonded with white retro reflective sheeting of Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3 Supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with grey stove enamel paint and supported on one no. of M. S. angle iron post of size 65 mm X 65 mm X 6 mm, 3.45 m long, duly painted with with flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in M25 grade concrete block of size 60cm X 60cm X 75cm including transportation etc; complete. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier.

32

-

-

... More
MMGSY / PMGSY Maintenance Information Board Providing and fixing of typical MMGSY / PMGSY Retro Reflective information board as per section 1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing.The ACP sheets of 3 mm thick, of 1500mmx900 mm size duly rivetted with MS angles of 25 x 25 x 5 mm thick M.S angle. Riveting of all the sheets over angle and flat iron frame will be done neatly to have plain surface on one side. The angle iron frame of the plate will be welded to two nos. 75mm x75mm (12 SWG) sheet tubes posts placed at 1125mm apart centre to centre. These two posts will be embeded in cement concrete M15 grade block of 600x600x750mm below ground level. The height of the bottom of the plate will be 775mm from normal ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications. All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.5 and as directed by Engineer-In-charge. . A warranty for 5 / 7 years for the Retro reflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor.

1

-

-

... More
Providing & fixing Hazard markers board Providing & fixing Hazard markers board in rectangular shape of size 0.30x0.90m made out of 16 guage (1.60mm) thick M.S.sheet with angle frame 25X25X5 mm for pannel ,black non reflective opaque back ground and yellow oblique engineering grade reflective bands & back side in gray stove enamal paint etc complete ,including one MS.angle iron post of 50mmx50mmx6mm 1.8 mtr long painted with synthetick enamel paint of black colour including in G.I.fixture etc & fixing the board in 1:2.5:3 (M-15 Grade) concrete block of size 45cm x45cmx60cm .including transportation etc . complete

76

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.