Pradhan Mantri Gram Sadak Yojana Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Pradhan Mantri Gram Sadak Yojana - PMGSY Tender

Works
Civil And Construction
Eprocure
Opening Date27 Sep 2024
Closing Date3 Oct 2024
Tender Amount₹ 5,19,63,689 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Get the Best Price For TMT
Starting from
₹54,000/MT*
Maharashtra

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with all lift and lead as per Technical Specification Clause 302.3

14600.84

1079732

73.95

... More
Construction of embankment with approved materials deposited at site from raodway cutting and excavation from drain and foundation of other structures graded and compacting with vibratory roller to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5

7789.16

527326

67.7

... More
Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5m, transporting to site, spreading , grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with all lead & lift as per technical Specification Clause 301.5

4881.59

2300937

471.35

... More
Construction of Earthen Shoulders as per Technical Specification Clause 407

2736.48

1711941

625.6

... More
Providing and fixing in position 25mm dia anti corrosive MS dowel bars of required dia. 60 Cms. Long and at 30.00 Cm C/C and wherever directed including handling, straightening, necessary cutting supported by chairs with proper alignment with half length covered by polyethene sheathing including cap etc. complete

20

4619

230.95

... More
Providing expansion joints with 25mm thick bituminous pad as per detailed drawings etc. complete.

7.91

8590

1086

... More
Construction of subgrade with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting with vibratory roller to meet requirement of Table 300.2 with all lead as per Technical Specification Clause 303.1

4082.35

2553918

625.6

... More
Dewatering on BHP basis by using water pump including diversion of stream, providing cofferdams, earthern bunds etc. as may be necessary for foundation and other parts of the the works and pumping out water during and after excavation as may be required by using 5.0 to 9.0 BHP pump etc. complete. (prior approval of Superintending Engineer will be necessary)

480

96480

201

... More
Removing all types of Hume pipes and stacking within a lead of 1000 m including Earthwork and Dismantalling of Masnory Works as per Technical Specification Clause 202

-

-

-

... More
(600MM TO 900MM DIA)

16.8

9880

588.1

... More
Hume pipes ( ABOVE 900 MM Ø PIPE)

25.2

25376

1007

... More
Bill No. 2 Pavement Works (GSB, WBM, Bituminous Works) and Cement Concrete Pavement Work

-

-

-

... More
Construction of granular sub-base by providing Grading-I material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.

1717.32

3743585

2179.9

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to Water Bound Macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 2 as per Technical Specification Clause 405.

2906.84

9849100

3388.25

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with vibratory roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405

1939.13

6334459

3266.65

... More
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.225 kg / sqm on the prepared bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503

25854.97

460218

17.8

... More
Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2mm to 5.6mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat as per Technical Specification Clause 508.(Using Waste Plastic)

14734.35

2582194

175.25

... More
20mm thick Open Graded Premix Carpet using Bitumen Emulsion as per Technical Specification Clause 508.2.

11120.62

1584132

142.45

... More
Providing and applying primer coat with Bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.85 Kg / sqm using mechanical means as per Technical specification Clause 502

25854.97

1455634

56.3

... More
Providing and laying Seal Coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, as per Technical Specification Clause 508

25854.97

1593958

61.65

... More
Providing and laying PVC Pipe 110mm Ø for Weephole

20

5100

255

... More
Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate (natural sand/ VSI grade finely washed crushed sand) conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor /by suitable means as approved by Engineer-in- charge, compacting with vibratory roller, finishing, curing and including preparation of sub-grade surface if required etc. complete.

30.94

122729

3966.7

... More
Providing and laying White Topping / Short Paneled Concrete as per IRC-SP 76-2015 (Existing surface preparation to be done if necessary either by milling or levelling course with DLC to correct surface profile and to be paid separately) with un reinforced M-40 Grade Pavement Quality Concrete using Ordinary Portland Cement 43/53 Grade OR Portland Pozzolona Cement IS-1489 at 425 Kg/Cum, coarse aggregate, fine aggregate (VSI) and admisture confirming to IS 9130-1999 (R-2004) polymeric synthetic fiber as per ASTM (1116) such as polyster / polyethylene / polypropylene / glass fiber at 1.20 Kg/Cum, mixed in batching and mixing plant or weigh batcher as per approved mix design to achieve minimum flexural strength or modulus of rupture of concrete 4.50 MPa at 28 days limiting maximum water, cement ratio to 0.40, transported to site laid with fixed form/ slip form paver finisher (preferably with slip form paver finisher) spread, vibrated, compacted and finished in a continuous operation to the lines and grades as per drawing, texture, finishing of surface, spraying two layers of curing compound, curing with water sprayed on hessian cloth covered over concrete surface, groove cutting and grid 1.00m x 1.00m or as directed by Engineer-in-Charge to a depth of 1/3 to 1/4 of the thickness and of width 3-5mm as per design including cost of all material, site formwork, labour and machineries etc. complete as per specification. (Excluding Dowel Bars & Tie Bars

56.31

449852

7988.85

... More
Bill No. 3 Cross Drainage Structures (Culverts & Minor Bridges), Drains and Protection Works

-

-

-

... More
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.

1846.32

1237495

670.25

... More
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead as per Technical Specification Clause 202.

-

-

-

... More
(I) Manual Means (B) Cement Concrete

76.04

71173

936

... More
(I) Manual Means (B) Reinforced Cement Concrete

9

22718

2524.3

... More
Providing rubble filling of trap/ granite/ quartzite/ gneiss stones for foundations including filling voids with sand/ grit and compaction etc complete.

85.53

210810

2464.75

... More
Providing concrete for plain cement concrete M-10 in foundations complete as per drawings and Technical Specification Clauses 802, 803, 1202 and 1203.

72.34

487741

6742.35

... More
Providing concrete for plain cement concrete M-15 in foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203

41.19

271281

6586.1

... More
Plain cement concrete Grade M-15 in substructure complete as per drawings and technical specifications Clause 802, 804, 805, 806, 807, 1202 and 1204

241.65

1671746

6918.05

... More
Providing and laying P.C.C. M-20 Grade cement concrete in substructure complete as per drawings and technical specification Clause 802, 804, 805, 806, 807, 1202 and 1204

91.91

685446

7457.8

... More
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material and single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets. Clause 1106.1000 mm Dia.

90

679477

7549.75

... More
Providing and laying cement concrete pipe of I.S.458/2003 NP Class-2 of 600mm diameter in proper line, level and slope including providing, fixing collars in C.M.1:2 and curing etc. complete. 600 mm Dia.

140

382620

2733

... More
Providing and laying reinforced cement concrete M-25 in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5

5.89

50949

8650.25

... More
Providing reinforced cement concrete M-30 in foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203

138.49

1087132

7849.9

... More
Sand filling in foundation trenches as per drawing and Technical Specification Clause 305.3.9

111.83

311278

2783.5

... More
Supplying fitting and placing TMT bar reinforcement (Fe 415) in substructure complete as per drawings and technical specification Clauses 1002, 1005, 1010 and 1202 .

9.08

721397

79449.1

... More
Supplying fitting and placing TMT bar reinforcement in superstructure complete as per drawings and technical specification Clauses 1002, 1010 and 1202

3.87

316519

81787.95

... More
Supplying fitting, and placing TMT bar reinforcement in foundation complete as per drawing and technical spcifications Clauses 1000 & 1202

7.31

578181

79094.65

... More
Providing pressure relief pipes 100 mm dia. in bottom slab of box cell on a filter media base of 500 mm x 500 mm as per drawing and technical specification Clause 1205.5.7

20

21004

1050.2

... More
Providing and laying filter media with granular crushed aggregates as per specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8

109.48

309176

2824.05

... More
Providing and laying 0.90meter thick metal mat consisting of rubble, oversize metal and normal size metal in specified thickness as per detailed drawing including supplying all materials, hand packing of rubble, spreading metal in layers and hard murum including watering and compaction with power roller etc. complete.

151.56

346541

2286.5

... More
Backfilling behind abutment, wing wall and return wall complete as per drawings and technical specification Clause 1204.3.8

191.49

651793

3403.8

... More
Providing weepholes in plain concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(v) :20(h) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7

80

24272

303.4

... More
Providing and laying of apron with cement concrete blocks of size as per Table 1300.1 cast-in-situ and made with nominal mix of M-15 grade cement concrete as per drawing and technical specifications Clause 1301

85.97

576102

6701.2

... More
Providing and laying cement concrete Wearing Course M-30 grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3

8.79

127824

14542.05

... More
Providing and laying reinforced cement concrete M-30 in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5

46.34

409932

8846.2

... More
Providing and laying R.C.C. M-30 Grade cement concrete in substructure complete as per drawings and technical specification Clause 802, 804, 805, 806, 807, 1202 and 1204

117.66

971253

8254.75

... More
Providing and fixing in position railing consisting of IS Rolled steel joist posts designation IS MB 100 (100 x 50) at 2.5m interval and three rows of 50 mm dia steel pipes (light) including fixing in position on bridge deck complete as per drawing and technical specifications Clause 1208.2

71.9

150263

2089.9

... More
Providing tar paper between cutoff & raft including laying in proper position etc. complete.

28.56

2827

99

... More
Providing and fixing 90cm x 60cm Marble plate engraving 10cm. Height letter, figures including painting the lefters/ figures with approved colour and shade complete

2

15288

7644

... More
Providing and laying filter material undermeath pitching in slopes complete as per drawing and Technical Specification Clause 1302

66.75

232773

3487.25

... More
Providing and laying pitching of cement concrete blocks of size as per Table 1300.2, cast in cement concrete of grade M-15

133.5

361851

2710.5

... More
Providing random rubble masonry in cement morter 1:5 in construction of toe walls for protection of slopes as per drawings and technical specifications Clause 1302.5

95

677017

7126.5

... More
Bill No. 4 Traffic Signs, Markings and Road Appurtenances, Road Safety & Road Furniture

-

-

-

... More
Reinforced cement concrete M-15 grade Ordinary Kilometer Stone (Precast) of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703.

7

20817

2973.9

... More
Reinforced cement concrete M-15 grade 200m Stone (Precast) of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703.

27

22519

834.05

... More
Reinforced cement concrete M-15 grade Boundary Pillar/ Local Stone of standard design as per IRC: 25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704.

390

327756

840.4

... More
Reinforced cement concrete M-15 grade 5th Kilometer Stone (Precast) of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703.

1

5108

5108.1

... More
Painting lines, dashes, arrows etc. on roads in two coats on new work with ready mixed road marking paint conforming to IS:164 on bituminous/concrete surface, including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control as per drawing and Technical Specification Clause 1702

155.4

38290

246.4

... More
Providing and Laying hot applied thermo plastic road marking strip on Bituminous Surface of specified shade/ colour of 2.5mm thick including 1.5 Refractive index reflectorizing glass beads @ 250 gm/ sqm. Thickness of 2.5mm is exclusive of surface applied glass beads as per IRC 35:2015. Initial Dry reflectivity RL shall be 250m cd/ sqm/ lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/ sqm/ lux and Qd of 100 mcd/ sqm/ lux measured at the end of 2 years by means of a Standard Reflecto meter of Zehntner, Easylux, Delta make capable of measuring RL & QD both according to IRC 35:2015 clause 15.5. The finished surface to be level, uniform, and free from streak sand holes complete as per direction of Engineer-in-charge and inaccordance with applicable specifications. (Refer MORTH Clause 803 for technical Specification and Performance for IRC 35:2015).

537.69

358101

666

... More
Construction of Rounded Hump Type Speed Breaker as per IRC : 99 (1988) for general traffic as per specification, including painting, fixing cautionery boards etc. complete and as directed by Engineer-in-Charge.

1

47807

47807.8

... More
Providing and fixing of typical MMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 (Item No. 10.16 / P.No. 52)

3

55046

18348.7

... More
Providing and fixing of retro- reflectorised informatory sign board rectangular/Square in shape having area less than 0.9 One Square Meterr made out of 4mm aluminum sheet bonded with white retro reflective sheeting of Class B (Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3, supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with two coats of grey stove enamel paint and supported on one no. mild steel angle iron post 75 mm x 75 mm x 6 mm, 3.5 mt long firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing The angle iron post shall be duly painted with one coat of epoxy primer and two coats of epoxy finish paints having alternate black and white bands of 25 cm width including GI fixures and transportation etc.complete.The nut bolts of board with angle iron post/supporting structure after fixing at site has to be electrically welded. Class B (Type IV High intensity micro-prismatic grade sheeting-HIP) sheeting shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier. (800mm x 600mm Rectangular )

8

78304

9788

... More
Providing and fixing Cautionary/Warning sign boards in Equilateral Triangle size of 600mm made out of 3mm aluminum sheet bonded with white retro reflective sheeting of Class B (Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3 Supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with grey stove enamel paint and supported on one no. of M. S. angle iron post of size 65 mm X 65 mm X 6 mm, 3.45 m long, duly painted with with flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in M25 grade concrete block of size 60cm X 60cm X 75cm including transportation etc; complete. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier. (600mm Equilatral and Triangle)

81

311607

3847

... More
Providing and fixing Mandatory/Regulatory sign boards in circular shape of 600mm dia made out of 3mm aluminum sheet bonded with white retro reflective sheeting of Class B (Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3 Supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with grey stove enamel paint and supported on one no. of M. S. angle iron post of size 65 mm X 65 mm X 6 mm, 3.45 m long, duly painted with with flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in M25 grade concrete block of size 60cm X 60cm X 75cm including transportation etc; complete. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier. ( 600mm Circular)

4

18064

4516

... More
Providing and fixing Cautionary/Warning sign boards in Octagone size of 900mm made out of 4mm aluminum sheet bonded with white retro reflective sheeting of Class B (Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3 Supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with grey stove enamel paint and supported on one no. of M. S. angle iron post of size 65 mm X 65 mm X 6 mm, 3.45 m long, duly painted with with flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in M25 grade concrete block of size 60cm X 60cm X 75cm including transportation etc; complete. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier. ( 900mm Sides Octagon)

1

8350

8350

... More
PMGSY Citizen' s information Board- Providing and fixing of typical PMGSY Retro Reflective information board as per as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing.Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottom duly rivetted with MS angles of 35 x 35 x 5 mm thick M.S angle shall be welded by two vertical M.S angle of 5 mm thick to 75 mm x 75 mm of 12 SWG square tubes / 75mm Dia Pipe posts duly embedded in cement concrete M-20 grade blocks of 600mm x 600mm x 75mm, below ground level. MMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/ Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4 and as directed by Engineer-In-charge. A warranty for 5 / 7 years for the Retro reflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor. (SoR 2019-20, Item No. 10.16 (A) / P.No. 42)

3

72320

24106.7

... More
Sign Board of PMGSY Project Information : Providing and fixing of typical retro reflective PMGSY Project informatory sign board with Logo as per section1700 of MORD specifications and latest MMGSY Signage Manual / Circuler and drawing. The board will be a composite unit consisting of Three Plates ACP (Aluminum Composite Panel), material specificaitons as per clause 17001.3. The top most plate will be of 3mm ACP in diamond shape of 600x600mm size, riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. The middle 4mm ACP plate of will be 1200x150mm size riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. The main 4mm ACP lower most plate will be 1500mmx600mm size, riveted with MS angle iron frame of 25mmx25mmx5mm size. Riveting of all the sheets over angle and flat iron frame will be done neatly to have plain surface on one side. The angle iron frame of lower most plate and flat iron frame of the middle plate will be welded to two nos. 75mm x75mm x 12 swg sheet tubes posts placed at 1125mm apart centre to centre. the top of the middle plate will be flushed with the top of 75mm dia medium steel tube posts and these posts will be embeded in cement concrete M15 grade block of 450x450x600mm below ground level. The height of the bottom of the lower plate will be 1200mm from normal ground level and the bottom of the middle plate will be 100mm above the top level of the lower most plate. the diamond shaped plate mounted over flat angle iron frame will be connected to middle plate by square steel section of 47mmx47mm, thickness 12SWG having a spacing of 100mm between the diamond shaped plate and middle plate and this square section will be riveted to the bottom point of the diamond shaped plate. PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013 (11)/ 3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.2 and as directed by Engineer-In-charge. . A warranty for 5 / 7 years for the Retro reflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor.

1

27147

27147.8

... More
Road Delineators: Supplying and installation of delineators (Roadway Indicators, Hazard markers, Object markers) 80 to 100 cm high above ground level, painted black and white in 15cm wide strips, fitted with 80x100mm rectangular or 75mm dia. circular reflectorised panels at the top, buried or pressed into the ground and confirming to I.R.C. 79 and the drawings

153

125766

822



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.