Pradhan Mantri Gram Sadak Yojana Tender
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Pradhan Mantri Gram Sadak Yojana - PMGSY Tender
Civil And Construction
Road Construction
Eprocure
Opening Date28 Jun 2024
Closing Date8 Jul 2024
Tender Amount₹ 2,37,33,912
Costs
EMD
₹ 1,50,000Document Cost
₹ 11,800Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_CEMAH_135115_1Bid Award Id
ViewTender No
MH2795Tender Authority
Pradhan Mantri Gram Sadak Yojana ViewPurchaser Address
-Website
http://http://omms.nic.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Loosening, Levelling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Tables 300.1 and 300.2 for embankment construction as per Technical Specification Clause 301.4
883.13
24833
28.12
Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with a lift upto 1.5 m and lead upto 1000 m as per Technical Specification Clause 302.3
3814.95
215735
56.55
Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, transporting to embankment site with a lift upto 1.5 m and lead upto 1000 m, trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections as per Technical Specification Clause 302.3.5
448.81
38871
86.61
Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal with a lift upto 1.5 m and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification Clause 302.3.5
224.41
85091
379.18
Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacting with vibratory roller to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5 Construction of Embankment with Material Obtained from Roadway Cutting
1795.27
130839
72.88
Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical specification 301.5 Construction of Embankment with Material Obtained from Borrow Pits
3025.77
1401294
463.12
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1.Construction of earthen shoulders with Material Available from Borrow Pit
1101.6
499652
453.57
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (II) For Grading II Material Granular sub-base with Well Graded Material(Table 400.1)
808.31
1636761
2024.91
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 2 as per Technical Specification Clause 405. .WBM Grading-II (Crushable Screenings)
1363.73
2966303
2175.14
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405. WBM Grading III (Stone Screening)
1144.35
2726368
2382.46
Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502
15258
1054938
69.14
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.20 to 0.25 kg per sqm on the prepared bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503.
21783
248544
11.41
Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508..(excluding seal coat) ( OGPC-Waste Plastic) )
15258
2102857
137.82
Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510. (Using Type A)
15258
1000924
65.6
Providing and fixing Cautionary /Warning sign boards in aluminum sheet bonded with white retroreflective sheeting of ClassB (Type IV High intensity micro-prismatic grade sheeting IP )having pressure sensitive /heat activated adhesive retoreflective specified background, border and back side retoreflctive symbols,letters,numerals,arrow as per IRC: 67-2012 Table No 8.3 Supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with grey stove enamel paint and supported on one no.of M.S.angle iron post of size 65mm X65mm X6mm ,3.45 m long,duly painted with with flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in M25 grade concrete block of size 60 cmX 60cmX 75cm including transportation etc;complete.Class B (Type IV High intensity micro-prismatic grade sheeting-HIP )shall have 7years written warranty from the manufacturer and authorised distributor /convertor issued for field performance including the screenprinted areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier .900 mm Equilateral triangle
2
9562
4781
Providing and fixing Cautionary /Warning sign boards in aluminum sheet bonded with white retroreflective sheeting of ClassB (Type IV High intensity micro-prismatic grade sheeting IP )having pressure sensitive /heat activated adhesive retoreflective specified background, border and back side retoreflctive symbols,letters,numerals,arrow as per IRC: 67-2012 Table No 8.3 Supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with grey stove enamel paint and supported on one no.of M.S.angle iron post of size 65mm X65mm X6mm ,3.45 m long,duly painted with with flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in M25 grade concrete block of size 60 cmX 60cmX 75cm including transportation etc;complete.Class B (Type IV High intensity micro-prismatic grade sheeting-HIP )shall have 7years written warranty from the manufacturer and authorised distributor /convertor issued for field performance including the screenprinted areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier. 600 mm Equilateral triangle
24
83256
3469
Providing and fixing Cautionary /Warning sign boards in aluminum sheet bonded with white retroreflective sheeting of ClassB (Type IV High intensity micro-prismatic grade sheeting IP )having pressure sensitive /heat activated adhesive retoreflective specified background, border and back side retoreflctive symbols,letters,numerals,arrow as per IRC: 67-2012 Table No 8.3 Supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with grey stove enamel paint and supported on one no.of M.S.angle iron post of size 65mm X65mm X6mm ,3.45 m long,duly painted with with flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in M25 grade concrete block of size 60 cmX 60cmX 75cm including transportation etc;complete.Class B (Type IV High intensity micro-prismatic grade sheeting-HIP )shall have 7years written warranty from the manufacturer and authorised distributor /convertor issued for field performance including the screenprinted areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier. 600 mm Circular
4
16320
4080
Providing and Fixing of Semi cautionary, mandatory, informatory sign boards as per IRC-67 made of 1.5 mm thick M.S. Sheet duly stove white colour in front and grey colour on back with red reflective border of 65 mm width and required message, letters, figures with reflective tape of engineering grade as per clause 1701.3.9 of MORD for Rural Roads of required shade and colour Supported and welded on 47 mm x 47 mm of 12 SWG square tube firmly fixed to the ground by means of properly designed foundations with M-15 grade cement concrete 450x 450x 600 mm, 600 mm below ground level as per approved drawing and Clause 1701.2.2Semi - Reflective Traffic signs. 900 X 600 Reactangular
2
11263
5631.76
Providing and Fixing of Semi cautionary, mandatory, informatory sign boards as per IRC-67 made of 1.5 mm thick M.S. Sheet duly stove white colour in front and grey colour on back with red reflective border of 65 mm width and required message, letters, figures with reflective tape of engineering grade as per clause 1701.3.9 of MORD for Rural Roads of required shade and colour Supported and welded on 47 mm x 47 mm of 12 SWG square tube firmly fixed to the ground by means of properly designed foundations with M-15 grade cement concrete 450x 450x 600 mm, 600 mm below ground level as per approved drawing and Clause 1701.2.2Semi - Reflective Traffic signs 600 x450 mm Reactangular
8
32776
4097
Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1
2
29814
14907.33
MMGSY / PMGSY Citizen' s information Board- Providing and fixing of typical PMGSY Retro Reflective information board as per as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circular and drawing. Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottom duly rivetted with MS angles of 35 x 35 x 5 mm thick M.S angle shall be welded by two vertical M.S angle of 5 mm thick to 75 mm x 75 mm of 12 SWG square tubes / 75mm Dia Pipe posts duly embedded in cement concrete M-20 grade blocks of 600mm x 600mm x 75mm, below ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circular no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4 and as directed by Engineer-In-charge. . A warranty for 5 / 7 years for the Retro reflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor.
2
62044
31022.1
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703.Ordinary Kilometer Stone (Precast)
5
12766
2553.35
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703.200 m stone (precast)
17
8999
529.4
Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area not exceeding 0.9 sqm supported on a mild steel single angle iron post 75 x 75 x 6 mm firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 x 450 x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701(0.9 Sqm. Board)
6
22241
3706.97
Providing and fixing of Road Stud 100 x 100 mm die cast in aluminium, resistant to corrosive effect of salt and grit, fitted with lense reflectors, installed in concrete or asphaltic surface by drilling holes 30 mm upto a depth of 600 mm and bedded in a s
81
34587
427
Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704
404
244092
604.19
Providing and Laying hot applied thermoplastic road marking strip on Bituminous Surface of specified shade /colour of 2.5mm thick including 1.5Refractive index reflectorizing glass beads @250 gm/sqm.Thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC 35:2015 .Initial Dry reflectivity RL shall be 250 mcd/sqm /lux measured in the initial 7days and sustained reflectivity RL of 100 mcd/sqm/ lux and Qd of 100 mcd /sqm /lux measured at the end of 2 years by means of a Standard Reflectometer of Zehntner , Easylux , Delta make capable of measuring RL & QD both according to IRC 35:2015 clause 15.5.The finished surface to be level, uniform, and free from streaks and holes complete as per direction of Engineer - in-charge and in accordance with applicable specifications. (Refer MORTH Clause 803 for technical Specification and Performance for IRC 35:2015).
404
269064
666
Painting lines, dashes, arrows, etc. on roads in two coats on new work with ready mixed road marking paint conforming to IS:164 on bituminous/concrete surface, including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control as per drawing and Technical Specification Clause 1702
200
39980
199.9
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202. Rubble Stone Masonry in Cement Mortar
29.88
5697
190.69
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202. Cement Concrete
18.11
13952
770.44
Removing all types of Hume pipes and stacking within a lead of 1000 m including Earthwork and Dismantling of Masonry Works as per Technical Specification Clause 202. (Item No 2.13) (B) Above 600 mm to 900 mm dia Hume pipe
22.5
10615
471.78
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary Soil
1614.55
868063
537.65
Earthwork in excavation for structures as per drawing and technical specification including setting out, construction of shoring and bracing, removal of stumps and other deleterious material, dressing of sides and bottom and backfilling in trenches with approved material. ( Item No 11.1 (I) Ordinary rock (not requiring blasting)
71.57
41086
574.07
Earthwork in excavation for structures as per drawing and technical specification including setting out, construction of shoring and bracing, removal of stumps and other deleterious material, dressing of sides and bottom and backfilling in trenches with approved material. ( Item No 11.1 (I) Hard rock (blasting prohibited)
10.36
8952
864.11
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 (P.C.C grade M 10) Nominal mix 1:3:6
119.85
678231
5659
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 P.C.C. grade M15 (Nominal mix (1:2:5:5:)
659.46
3962726
6009.02
Supplying, fitting and placing HYSD bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
14.28
897646
62860.41
Providing and laying reinforced cement concrete pipe NP2 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. FOR NP2 (600mm Dia.)
65
174070
2678
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. FOR NP3 (600mm Dia.)
82.5
391875
4750
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106.. For NP-3 (1000 MM DIA. )
67.5
481945
7139.94
Filling the trench as per drawing and technical specification clause 305.3.9 Rubble soling
268.54
541247
2015.52
Providing & fixing G.I. wire Gabions coated with Zinc+PVC of required size, section including boxes made of mechanically woven hexagonal shaped wire mesh of type, 10x12cm. edges mechanically selvedged made of heavily (Zinc+ PVC) coated G.I. wires as per BS: 443, mesh wire 3.00 mm ? edge wire 3.9 mm ? and filled with 20 to 50 kilogram weight trap stones including conveying with all the leads & lifts and placing at required places in required line, level, slope as per drawing, section as directed etc. complete under tidal conditions.
(a) Gabions of size ? 1.00 x 1.00 x 1.00 M
40
130420
3260.52
Providing & fixing G.I. wire Gabions coated with Zinc+PVC of required size, section including boxes made of mechanically woven hexagonal shaped wire mesh of type, 10x12cm. edges mechanically selvedged made of heavily (Zinc+ PVC) coated G.I. wires as per BS: 443, mesh wire 3.00 mm ? edge wire 3.9 mm ? and filled with 20 to 50 kilogram weight trap stones including conveying with all the leads & lifts and placing at required places in required line, level, slope as per drawing, section as directed etc. complete under tidal conditions.
(c) Gabions of size ? 2.00 x 1.00 x 1.00 M
80
224361
2804.52
Metal Beam Crash Barrier -- Type - A, W : Metal Beam Crash Barrier (Providing and erecting a W "metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810)"
40
177800
4445
Printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade as per drawings and Technical Specification Clause 1701
2868
2495
0.87
Evaluation Notes How It Works ?