Pradhan Mantri Gram Sadak Yojana Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Pradhan Mantri Gram Sadak Yojana - PMGSY Tender

Works
Civil And Construction
Road Construction
Eprocure
Opening Date4 Oct 2024
Closing Date11 Oct 2024
Tender Amount₹ 10,13,44,233 
Notes
Download

Costs

Summary

Pacakge No. Mh-01-151 Upgradation And 5 Year Maint Mdr 37 Gevrai To Bhendha Kh 2.narayanwadi Nipani Nimgoan Kharwandi To Hingoni To Vitthalwadi 3.sonai Belhekarwadi To Mdr-32 Tal.newasa Dist.ahmednagar

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cubicmeter bucket capacity including cutting and loading in tippers, transporting to embankment site with all lift and all lead , trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections as per Technical Specification Ministry Of Rural Development 2014 Clause 302.3.5 And As Directed by Engineer Incharge

1402.62

152464

108.7

... More
Scarifying existing bituminous surface to a depth of 150 mm and disposal of scarified material with all lift and all leads as per Technical Specification Clause 301.4. as per Technical Specification Clause 301.4 And As Directed by Engineer Incharge

3825

60435

15.8

... More
Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Ministry Of Rural Development 2014 Clause 301.5 And As Directed by Engineer Incharge

3341.34

280171

83.85

... More
Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 And As Directed by Engineer Incharge

3415.27

1809751

529.9

... More
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 as per Technical Specification Ministry Of Rural Development 2014 Clause 303.1. And As Directed by Engineer Incharge

6048.91

3812023

630.2

... More
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.(For Grading II Material). And As Directed by Engineer Incharge

170.14

354920

2086.05

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kilonewton static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Water bound macadum Grading 2 using 100% crushed Aggregate as per Technical Specification Ministry Of Rural Development 2014 Clause 405. For - By Mechanical Means And As Directed by Engineer Incharge

2921.67

6550968

2242.2

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 using 100% crushed Aggregate as per Technical Specification Clause 405

1822.43

4583320

2514.95

... More
Providing and applying primer coat with Bitumen emulsion (SS-1 IS8887) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70- 1.0 kg/sqm using mechanical means as per Technical Specification Clause 502. And As Directed by Engineer Incharge

24299

1764107

72.6

... More
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.20 to 0.25 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503. And As Directed by Engineer Incharge

24299

303737

12.5

... More
Providing, laying and rolling of open-graded premix carpet (using 8% plastic) of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508.. For -Case - II By Mechanical MeansBitumen (S-65) Viscosity Grade-30 (1.3432 kilogram per squaremeter) And As Directed by Engineer Incharge

24299

3780924

155.6

... More
Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A as per Technical Specification Ministry Of Rural Development 2014 Clause 508 Case - I : Type A Bitumen (S-65) Viscocity grade-30 by Mechanical Means (0.98 kilogram per squaremeter) And As Directed by Engineer Incharge

24299

1615883

66.5

... More
Providing and laying White Topping/Short Paneled Concrete as per IRC-SP 76-2015 (Existing surface preparation to be done if necessary either by milling or leveling course with DLC to correct surface profile and to be paid separately) with un reinforced M-40 grade Pavement Quality Concrete using Ordinary Portland Cement 43/53 Grade OR Portland Pozzolona Cement IS-1489 at 425kg/cum, coarse aggregate, fine aggregate(VSI) and Admixture confirming to IS 9130-1999 (R-2004) polymeric synthetic fiber as per ASTM (1116) such as polyester / polyethylene / polypropylene / Glass fiber at 1.20 kg/cum, mixed in batching and mixing plant or weigh batcher as per approved mix design to achieve minimum flexural strength or modulus of rupture of concrete 4.50 MPa at 28 days limiting maximum water cement ratio to 0.40, transported to site, laid with fixed form/ slip form paver finisher (preferably with slip form paver finisher), spread, vibrated, compacted and finished in a continuous operation to the lines and grades as per drawing, texture finishing of surface, spraying two layers of curing compound, curing with water sprayed on hessian cloth covered over concrete surface, groove cutting grid 1m x 1m or as directed by Engineer Incharge to a depth of 1/3 to 1/4 of the Thickness and of width 3-5 mm as per design including cost of all material, side form work, labour and machineries etc. complete as per specifications.(Excluding Dowel Bars and Tie Bars) ( Including Polythene sheet 125 micron) And As Directed by Engineer Incharge

225

1676565

7451.4

... More
Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate ( natural sand/ VSI grade finely washed crushed sand) conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, , cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days,mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts,laid with a paver with electronic sensor /by suitable means as approved by Engineer-in charge , compacting with vibratory roller, finishing, curing and including preparation of sub-grade surface if required etc. complete. And As Directed by Engineer Incharge

150

516645

3444.3

... More
Providing and fixing in position 25mm dia anti corrosive MS dowel bars of required Dia. 60 cms. Long and at 30.00 cm. C/C and wherever directed including handling. straightening, necessary cutting supported by chairs with proper alignment with half length covered by polyethene sheathing including cap etc. complete. And As Directed by Engineer Incharge

24

5574

232.29

... More
Providing and fixing in position anticorrosive TMT FE 500 tie bars of 12 mm dia. 70 cms. long and at 30.00 cm. C/C and wherever directed including handling, straightening necessary cutting, handling, straightening, supported by assembly of TMT FE 500, chairs with proper alignment etc. complete. And As Directed by Engineer Incharge

1333

84632

63.49

... More
Dismantling Stone Masonry as per Technical Specification MORD 2014 Clause 202. Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and all lead as per Technical Specification MORD 2014 Clause 202. Rubble Stone Masonry in Cement Mortar And As Directed by Engineer Incharge

56.7

34068

600.85

... More
Removing all types of Hume pipes and stacking with all lead including Earthwork and Dismantling of Masonry Works as per Technical Specification MORD 2014 Clause 202. Upto 600 mm dia Hume pipe And As Directed by Engineer Incharge

30

17643

588.1

... More
Earthwork in excavation for structures as per drawing and technical specifications Ministry Of Rural Development 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal all lead , dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary soil And As Directed by Engineer Incharge

561.85

376579

670.25

... More
Earthwork in excavation for structures as per drawing and technical specifications Ministry Of Rural Development 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal all lead, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary rock (not requiring blasting) Upto 3 meter depth And As Directed by Engineer Incharge

80.54

67480

837.85

... More
Filling in foundation trenches as per drawing and technical specification Clause 305.3.9 Rubble soling with Rubble And As Directed by Engineer Incharge

81.92

160423

1958.3

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 Plane cement concreate grade M 10 with crushed sand VSI crusher Nominal mix 1:3:6 And As Directed by Engineer Incharge

132.57

826017

6230.8

... More
Providing concrete for plain/reinforced concrete in sub structure complete as per drawings and technical specifications Ministry Of Rural Development 2014 Clause 802, 803, 804, 805, 806, 807, 1202 & 1203, 1204 Plain cement concreate grade M 15 with crushed sand VSI crusher Nominal mix (1:2.5:5) And As Directed by Engineer Incharge

442.43

2870662

6488.4

... More
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. B. 1000 milimeter Non pressure 3 Class As per Technical Specification Ministry Of Rural Development 2014 Cluase No. 1100 And As Directed by Engineer Incharge

110

830472

7549.75

... More
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. D. 600 milimeter Non pressure 3 Class As per Technical Specification Ministry Of Rural Development 2014 Cluase No. 1100 And As Directed by Engineer Incharge

120

463956

3866.3

... More
Providing and laying reinforced cement concrete pipe Non pressure2 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. D. 600 milimeter Non pressure 2 Class As per Technical Specification Ministry Of Rural Development 2014 Cluase No. 1100 And As Directed by Engineer Incharge

295

806235

2733

... More
Providing and laying cement concrete wearing course M30 grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3 And As Directed by Engineer Incharge

6.3

88815

14097.75

... More
Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1303 And As Directed by Engineer Incharge

90

187956

2088.4

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per Indian Road Congress:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Ministry Of Rural Development 2014 Clause 1703 5th Kilometre Stone (Precast) And As Directed by Engineer Incharge

1

5108

5108.1

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per Indian Road Congress:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Ministry Of Rural Development 2014 Clause 1703 Ordinary Kilometer Stone (Precast) And As Directed by Engineer Incharge

7

20817

2973.9

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per Indian Road Congress:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Ministry Of Rural Development 2014 Clause 1703 200 meter stone (precast) And As Directed by Engineer Incharge

29

24187

834.05

... More
Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per Indian Road Congress:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704. And As Directed by Engineer Incharge

272

228588

840.4

... More
Providing and fixing of typical PMGSY Retro Reflective information board as per as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing.Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottom duly rivetted with MS angles of 35 x 35 x 5 mm thick M.S angle shall be welded by two vertical M.S angle of 5 mm thick to 75 mm x 75 mm of 12 SWG square tubes / 75mm Dia Pipe posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 75mm, below ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2022. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 7 years for Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4 and as directed by Engineer-In-charge. . A warranty for 7 years for the Retro reflective sheeting for Class-B respectively, from original manufacturer shall be submitted by contractor. And As Directed by Engineer Incharge

2

37083

18541.95

... More
Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1. And As Directed by Engineer Incharge

2

36697

18348.7

... More
Providing and erecting direction and place identification of semi reflective sign boards as per IRC-67 made of 2 mm thick M.S. Sheet duly stove enameled paint white colour in front and grey colour on back with reflective border of 70 mm width and required message, letters, figures with reflective tape of engineering grade as per MORD specifications of required shade and colour. Supported and welded on two nos. 47 mm x 47 mm of 12 SWG square tube of 3050 mm height duly strengthened by 25 mm x 5 mm MS flat iron on edges on back firmly fixed to the ground by means of properly designed foundations with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701 .And As Directed by Engineer Incharge

9

36985

4109.5

... More
Providing and fixing Cautionary/Warning sign boards in Equilateral Triangle size of mm made out of mm aluminum sheet bonded with white retro reflective sheeting of Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3 Supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with grey stove enamel paint and supported on one no. of M. S. angle iron post of size 65 mm X 65 mm X 6 mm, 3.45 m long, duly painted with with flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in M25 grade concrete block of size 60cm X 60cm X 75cm including transportation etc; complete. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier. And As Directed by Engineer Incharge

60

229740

3829

... More
Providing and fixing of retro- reflectorised informatory sign board rectangular/Square in shape having area less than 0.9 One Square Meterr made out of mm aluminum sheet bonded with white retro reflective sheeting of Class ( Type IV High intensity micro- prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3, supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with two coats of grey stove enamel paint and supported on one no. mild steel angle iron post 75 mm x 75 mm x 6 mm, 3.5 mt long firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing The angle iron post shall be duly painted with one coat of epoxy primer and two coats of epoxy finish paints having alternate black and white bands of 25 cm width including GI fixures and transportation etc.complete.The nut bolts of board with angle iron post/supporting structure after fixing at site has to be electrically welded. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) sheeting shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier. 600 x 450 milimeter Rectangular And As Directed by Engineer Incharge

3.78

36541

9667

... More
Providing and fixing Mandatory/Regulatory sign boards in circular shape of mm dia made out of mm aluminum sheet bonded with white retro reflective sheeting of Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3 Supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with grey stove enamel paint and supported on one no. of M. S. angle iron post of size 65 mm X 65 mm X 6 mm, 3.45 m long, duly painted with with flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in M25 grade concrete block of size 60cm X 60cm X 75cm including transportation etc; complete. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier. 600mm circular And As Directed by Engineer Incharge

60

270960

4516

... More
Providing and Laying hot applied thermoplastic road marking strip on Bituminous Surface of specified shade/ colour of 2.5 mm thick including 1.5 Refractive index reflectorizing glass beads @ 250gm/sqm .Thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC 35:2015. Initial Dry reflectivity RL shall be 250 mcd/sqm/lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/sqm/ lux and Qd of 100 mcd/sqm/ lux measured at the end of 2 years by means of a Standard Reflectometer of Zehntner, Easylux, Delta make capable of measuring RL & QD both according to IRC 35:2015 clause 15.5. The finished surface to be level, uniform, and free from streaks and holes complete as per direction of Engineer-in-charge and in accordance with applicable specifications.(Refer MORTH Clause 803 for technical Specification and Performance for IRC 35:2015). And As Directed by Engineer Incharge

1360

905760

666

... More
Road Delineators: Supplying and installation of delineators (Roadway Indicators, Hazard markers, Object markers) 80 to 100 cm high above ground level, painted black and white in 15cm wide strips, fitted with 80x100mm rectangular or 75mm dia. Circular reflectorised panels at the top, buried or pressed into the ground and confirming to I.R.C. 79 and the drawings And As Directed by Engineer Incharge

30

24660

822

... More
Providing and fixing in position Pipe Railing consisting of IS Rolled steel joist posts designation IS MB 100 (100x75) at 2.5 m interval and three rows of 50 mm dia steel pipes (light) including fixing in position on bridge deck complete as per drawing and technical specifications Clause 1208.2 And As Directed by Engineer Incharge

130

271687

2089.9

... More
Painting two coats including prime coat with epoxy paint of approved brand on concrete/steel surfaces after through cleaning of surface to give an even shade as per drawing and Technical Specification Clause 1701 And As Directed by Engineer Incharge

5.4

893

165.45

... More
White washing two coats on parapet walls and white washing and geru lime painting to tree trunks including preparation of surface by cleaning scraping etc. complete And As Directed by Engineer Incharge

33

858

26

... More
A,W : Metal Beam Crash Barrier (Providing and erecting a "W "metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip cess, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810) And As Directed by Engineer Incharge

150

736800

4912

... More
B) Improvement of Road from Narayanwadi Nipani Nimgoan Kharwandi to Hingoni to Vitthalwadi road (Part-Hingoni to Vithalwadi Road), Km 0/000 to 3/530, Taluka -Newasa, District:- Ahmednagar, Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 milimeter, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, all lead including removal and disposal of top organic soil not exceeding 150 milimeter in thickness as per Technical Specification Ministry Of Rural Development 2014 Clause 201. By mechnical means (A) In area Non of thorny jungle And As Directed by Engineer Incharge

1.06

28122

26530.8

... More
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 milimeter, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, all lead including removal and disposal of top organic soil not exceeding 150 milimeter in thickness as per Technical Specification Ministry Of Rural Development 2014 Clause 201.By mechnical means (B) In area of thorny jungle And As Directed by Engineer Incharge

0.71

23414

32978.7

... More
Excavation for roadwork in soil with hydraulic excavator of 0.9 cubicmeter bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with all lift and all lead as per Technical Specification Ministry Of Rural Development 2014 Clause 302.3 And As Directed by Engineer Incharge

6004.25

444014

73.95

... More
Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cubicmeter bucket capacity including cutting and loading in tippers, transporting to embankment site with all lift and all lead , trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections as per Technical Specification Ministry Of Rural Development 2014 Clause 302.3.5 And As Directed by Engineer Incharge

316.02

34351

108.7

... More
Scarifying existing bituminous surface to a depth of 150 mm and disposal of scarified material with all lift and all leads as per Technical Specification Clause 301.4. as per Technical Specification Clause 301.4 And As Directed by Engineer Incharge

1296

20476

15.8

... More
Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Ministry Of Rural Development 2014 Clause 301.5 And As Directed by Engineer Incharge

610.31

51174

83.85

... More
Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 And As Directed by Engineer Incharge

6060.87

3460453

570.95

... More
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 as per Technical Specification Ministry Of Rural Development 2014 Clause 303.1. And As Directed by Engineer Incharge

1492.48

1004439

673

... More
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.(For Grading II Material). And As Directed by Engineer Incharge

730.7

1613641

2208.35

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kilonewton static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Water bound macadum Grading 2 using 100% crushed Aggregate as per Technical Specification Ministry Of Rural Development 2014 Clause 405. For - By Mechanical Means And As Directed by Engineer Incharge

749.6

1776327

2369.7

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 using 100% crushed Aggregate as per Technical Specification Clause 405

953.22

2528749

2652.85

... More
Providing and applying primer coat with Bitumen emulsion (SS-1 IS8887) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70- 1.0 kg/sqm using mechanical means as per Technical Specification Clause 502. And As Directed by Engineer Incharge

12709.5

923980

72.7

... More
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.20 to 0.25 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503. And As Directed by Engineer Incharge

12709.5

159504

12.55

... More
Providing, laying and rolling of close-graded premix surfacing material of 25 mm thickness composed of 11.2 mm to 0.9 mm (Type-A) or 13.2 mm to 0.9 mm (Type-B) aggregates using penetration grade bitumen (using 8% waste Plastic by wt of Bitumen) to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 8-10 kN static roller and finishing to required level and grades as per Technical Specification Clause 509 And As Directed by Engineer Incharge

12709.5

2735719

215.25

... More
Providing and laying White Topping/Short Paneled Concrete as per IRC-SP 76-2015 (Existing surface preparation to be done if necessary either by milling or leveling course with DLC to correct surface profile and to be paid separately) with un reinforced M-40 grade Pavement Quality Concrete using Ordinary Portland Cement 43/53 Grade OR Portland Pozzolona Cement IS-1489 at 425kg/cum, coarse aggregate, fine aggregate(VSI) and Admixture confirming to IS 9130-1999 (R-2004) polymeric synthetic fiber as per ASTM (1116) such as polyester / polyethylene / polypropylene / Glass fiber at 1.20 kg/cum, mixed in batching and mixing plant or weigh batcher as per approved mix design to achieve minimum flexural strength or modulus of rupture of concrete 4.50 MPa at 28 days limiting maximum water cement ratio to 0.40, transported to site, laid with fixed form/ slip form paver finisher (preferably with slip form paver finisher), spread, vibrated, compacted and finished in a continuous operation to the lines and grades as per drawing, texture finishing of surface, spraying two layers of curing compound, curing with water sprayed on hessian cloth covered over concrete surface, groove cutting grid 1m x 1m or as directed by Engineer Incharge to a depth of 1/3 to 1/4 of the Thickness and of width 3-5 mm as per design including cost of all material, side form work, labour and machineries etc. complete as per specifications.(Excluding Dowel Bars and Tie Bars) ( Including Polythene sheet 125 micron) And As Directed by Engineer Incharge

112.5

858105

7627.6

... More
Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate ( natural sand/ VSI grade finely washed crushed sand) conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, , cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days,mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts,laid with a paver with electronic sensor /by suitable means as approved by Engineer-in charge , compacting with vibratory roller, finishing, curing and including preparation of sub-grade surface if required etc. complete. And As Directed by Engineer Incharge

21

75951

3616.75

... More
Providing and fixing in position 25mm dia anti corrosive MS dowel bars of required Dia. 60 cms. Long and at 30.00 cm. C/C and wherever directed including handling. straightening, necessary cutting supported by chairs with proper alignment with half length covered by polyethene sheathing including cap etc. complete. And As Directed by Engineer Incharge

12

2787

232.3

... More
Providing and fixing in position anticorrosive TMT FE 500 tie bars of 12 mm dia. 70 cms. long and at 30.00 cm. C/C and wherever directed including handling, straightening necessary cutting, handling, straightening, supported by assembly of TMT FE 500, chairs with proper alignment etc. complete. And As Directed by Engineer Incharge

667

42354

63.5

... More
Dismantling Stone Masonry as per Technical Specification MORD 2014 Clause 202. Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and all lead as per Technical Specification MORD 2014 Clause 202. Rubble Stone Masonry in Cement Mortar And As Directed by Engineer Incharge

3.9

2343

600.85

... More
Removing all types of Hume pipes and stacking with all lead including Earthwork and Dismantling of Masonry Works as per Technical Specification MORD 2014 Clause 202. Upto 600 mm dia Hume pipe And As Directed by Engineer Incharge

7.5

4410

588.1

... More
Earthwork in excavation for structures as per drawing and technical specifications Ministry Of Rural Development 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal all lead , dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary soil And As Directed by Engineer Incharge

494.05

331137

670.25

... More
Filling in foundation trenches as per drawing and technical specification Clause 305.3.9 Rubble soling with Rubble And As Directed by Engineer Incharge

81.12

169703

2092

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 Plane cement concreate grade M 10 with crushed sand VSI crusher Nominal mix 1:3:6 And As Directed by Engineer Incharge

122.6

780471

6366

... More
Providing concrete for plain/reinforced concrete in sub structure complete as per drawings and technical specifications Ministry Of Rural Development 2014 Clause 802, 803, 804, 805, 806, 807, 1202 & 1203, 1204 Plain cement concreate grade M 15 with crushed sand VSI crusher Nominal mix (1:2.5:5) And As Directed by Engineer Incharge

306.57

2025983

6608.55

... More
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. B. 1000 milimeter Non pressure 3 Class As per Technical Specification Ministry Of Rural Development 2014 Cluase No. 1100 And As Directed by Engineer Incharge

57.5

434110

7549.75

... More
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. D. 600 milimeter Non pressure 3 Class As per Technical Specification Ministry Of Rural Development 2014 Cluase No. 1100 And As Directed by Engineer Incharge

142.5

550947

3866.3

... More
Providing and laying reinforced cement concrete pipe Non pressure2 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. D. 600 milimeter Non pressure 2 Class As per Technical Specification Ministry Of Rural Development 2014 Cluase No. 1100 And As Directed by Engineer Incharge

160

441656

2760.35

... More
Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1303 And As Directed by Engineer Incharge

27

59467

2202.5

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per Indian Road Congress:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Ministry Of Rural Development 2014 Clause 1703 Ordinary Kilometer Stone (Precast) And As Directed by Engineer Incharge

4

11895

2973.9

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per Indian Road Congress:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Ministry Of Rural Development 2014 Clause 1703 200 meter stone (precast) And As Directed by Engineer Incharge

14

11676

834.05

... More
Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per Indian Road Congress:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704. And As Directed by Engineer Incharge

142

119336

840.4

... More
Providing and fixing of typical PMGSY Retro Reflective information board as per as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing.Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottom duly rivetted with MS angles of 35 x 35 x 5 mm thick M.S angle shall be welded by two vertical M.S angle of 5 mm thick to 75 mm x 75 mm of 12 SWG square tubes / 75mm Dia Pipe posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 75mm, below ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2022. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 7 years for Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4 and as directed by Engineer-In-charge. . A warranty for 7 years for the Retro reflective sheeting for Class-B respectively, from original manufacturer shall be submitted by contractor. And As Directed by Engineer Incharge

2

37083

18541.95

... More
Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1. And As Directed by Engineer Incharge

2

36697

18348.7

... More
Providing and erecting direction and place identification of semi reflective sign boards as per IRC-67 made of 2 mm thick M.S. Sheet duly stove enameled paint white colour in front and grey colour on back with reflective border of 70 mm width and required message, letters, figures with reflective tape of engineering grade as per MORD specifications of required shade and colour. Supported and welded on two nos. 47 mm x 47 mm of 12 SWG square tube of 3050 mm height duly strengthened by 25 mm x 5 mm MS flat iron on edges on back firmly fixed to the ground by means of properly designed foundations with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701 .And As Directed by Engineer Incharge

6

24657

4109.5

... More
Providing and fixing Cautionary/Warning sign boards in Equilateral Triangle size of mm made out of mm aluminum sheet bonded with white retro reflective sheeting of Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3 Supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with grey stove enamel paint and supported on one no. of M. S. angle iron post of size 65 mm X 65 mm X 6 mm, 3.45 m long, duly painted with with flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in M25 grade concrete block of size 60cm X 60cm X 75cm including transportation etc; complete. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier. And As Directed by Engineer Incharge

34

131488

3867.3

... More
Providing and fixing of retro- reflectorised informatory sign board rectangular/Square in shape having area less than 0.9 One Square Meterr made out of mm aluminum sheet bonded with white retro reflective sheeting of Class ( Type IV High intensity micro- prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3, supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with two coats of grey stove enamel paint and supported on one no. mild steel angle iron post 75 mm x 75 mm x 6 mm, 3.5 mt long firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing The angle iron post shall be duly painted with one coat of epoxy primer and two coats of epoxy finish paints having alternate black and white bands of 25 cm width including GI fixures and transportation etc.complete.The nut bolts of board with angle iron post/supporting structure after fixing at site has to be electrically welded. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) sheeting shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier. 600 x 450 milimeter Rectangular And As Directed by Engineer Incharge

1.08

10544

9763.65

... More
Providing and fixing Mandatory/Regulatory sign boards in circular shape of mm dia made out of mm aluminum sheet bonded with white retro reflective sheeting of Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3 Supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with grey stove enamel paint and supported on one no. of M. S. angle iron post of size 65 mm X 65 mm X 6 mm, 3.45 m long, duly painted with with flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in M25 grade concrete block of size 60cm X 60cm X 75cm including transportation etc; complete. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier. 600mm circular And As Directed by Engineer Incharge

28

127712

4561.15

... More
Providing and Laying hot applied thermoplastic road marking strip on Bituminous Surface of specified shade/ colour of 2.5 mm thick including 1.5 Refractive index reflectorizing glass beads @ 250gm/sqm .Thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC 35:2015. Initial Dry reflectivity RL shall be 250 mcd/sqm/lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/sqm/ lux and Qd of 100 mcd/sqm/ lux measured at the end of 2 years by means of a Standard Reflectometer of Zehntner, Easylux, Delta make capable of measuring RL & QD both according to IRC 35:2015 clause 15.5. The finished surface to be level, uniform, and free from streaks and holes complete as per direction of Engineer-in-charge and in accordance with applicable specifications.(Refer MORTH Clause 803 for technical Specification and Performance for IRC 35:2015). And As Directed by Engineer Incharge

706

474890

672.65

... More
Road Delineators: Supplying and installation of delineators (Roadway Indicators, Hazard markers, Object markers) 80 to 100 cm high above ground level, painted black and white in 15cm wide strips, fitted with 80x100mm rectangular or 75mm dia. Circular reflectorised panels at the top, buried or pressed into the ground and confirming to I.R.C. 79 and the drawings And As Directed by Engineer Incharge

42

34868

830.2

... More
Providing and fixing in position Pipe Railing consisting of IS Rolled steel joist posts designation IS MB 100 (100x75) at 2.5 m interval and three rows of 50 mm dia steel pipes (light) including fixing in position on bridge deck complete as per drawing and technical specifications Clause 1208.2 And As Directed by Engineer Incharge

10

20899

2089.9

... More
Painting two coats including prime coat with epoxy paint of approved brand on concrete/steel surfaces after through cleaning of surface to give an even shade as per drawing and Technical Specification Clause 1701 And As Directed by Engineer Incharge

2.4

397

165.5

... More
White washing two coats on parapet walls and white washing and geru lime painting to tree trunks including preparation of surface by cleaning scraping etc. complete And As Directed by Engineer Incharge

12

312

26

... More
A,W : Metal Beam Crash Barrier (Providing and erecting a "W "metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip cess, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810) And As Directed by Engineer Incharge

90

442080

4912

... More
C) Improvement of Road from Sonai Belhekarwadi to MDR-32 (Khedle Parmanand ) Road ch 0/000 to 5/600 Taluka -Newasa, District:- Ahmednagar, Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 milimeter, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, all lead including removal and disposal of top organic soil not exceeding 150 milimeter in thickness as per Technical Specification Ministry Of Rural Development 2014 Clause 201. By mechnical means (A) In area Non of thorny jungle And As Directed by Engineer Incharge

1.68

44571

26530.8

... More
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 milimeter, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, all lead including removal and disposal of top organic soil not exceeding 150 milimeter in thickness as per Technical Specification Ministry Of Rural Development 2014 Clause 201.By mechnical means (B) In area of thorny jungle And As Directed by Engineer Incharge

1.12

36936

32978.7

... More
Excavation for roadwork in soil with hydraulic excavator of 0.9 cubicmeter bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with all lift and all lead as per Technical Specification Ministry Of Rural Development 2014 Clause 302.3 And As Directed by Engineer Incharge

9902.84

732315

73.95

... More
Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cubicmeter bucket capacity including cutting and loading in tippers, transporting to embankment site with all lift and all lead , trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections as per Technical Specification Ministry Of Rural Development 2014 Clause 302.3.5 And As Directed by Engineer Incharge

521.2

56654

108.7

... More
Scarifying existing bituminous surface to a depth of 150 mm and disposal of scarified material with all lift and all leads as per Technical Specification Clause 301.4. as per Technical Specification Clause 301.4 And As Directed by Engineer Incharge

17033

269121

15.8

... More
Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Ministry Of Rural Development 2014 Clause 301.5 And As Directed by Engineer Incharge

1459.37

122368

83.85

... More
Construction of embankment with approved material obtained from borrow pits with all lift, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 lead more than 250 metre as per Technical Specification Ministry Of Rural Development 2014 Clause 301.5 And As Directed by Engineer Incharge

8688

4841822

557.3

... More
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 as per Technical Specification Ministry Of Rural Development 2014 Clause 303.1. And As Directed by Engineer Incharge

4103.33

2703273

658.8

... More
Construction of Granular sub-base using 100% crushed Aggregate & of grade -II by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator and compacting with vibretary wheel roller to achieve the desired density, complete as per Technical Specification Ministry Of Rural Development 2014 Clause 401. And As Directed by Engineer Incharge

895.1

1942725

2170.4

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kilonewton static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Water bound macadum Grading 2 using 100% crushed Aggregate as per Technical Specification Ministry Of Rural Development 2014 Clause 405. For - By Mechanical Means And As Directed by Engineer Incharge

1398.25

3257503

2329.7

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 using 100% crushed Aggregate as per Technical Specification Clause 405

1351.36

3526914

2609.9

... More
Providing and applying primer coat with Bitumen emulsion (SS-1 IS8887) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70- 1.0 kg/sqm using mechanical means as per Technical Specification Clause 502. And As Directed by Engineer Incharge

18010.3

1306647

72.55

... More
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.20 to 0.25 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503. And As Directed by Engineer Incharge

18010.3

225128

12.5

... More
Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. And As Directed by Engineer Incharge

18010.3

2752874

152.85

... More
Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A as per Technical Specification Ministry Of Rural Development 2014 Clause 508 Case - I : Type A Bitumen (S-65) Viscocity grade-30 by Mechanical Means (0.98 kilogram per squaremeter) And As Directed by Engineer Incharge

18010.3

1206690

67

... More
Providing and laying White Topping/Short Paneled Concrete as per IRC-SP 76-2015 (Existing surface preparation to be done if necessary either by milling or leveling course with DLC to correct surface profile and to be paid separately) with un reinforced M-40 grade Pavement Quality Concrete using Ordinary Portland Cement 43/53 Grade OR Portland Pozzolona Cement IS-1489 at 425kg/cum, coarse aggregate, fine aggregate(VSI) and Admixture confirming to IS 9130-1999 (R-2004) polymeric synthetic fiber as per ASTM (1116) such as polyester / polyethylene / polypropylene / Glass fiber at 1.20 kg/cum, mixed in batching and mixing plant or weigh batcher as per approved mix design to achieve minimum flexural strength or modulus of rupture of concrete 4.50 MPa at 28 days limiting maximum water cement ratio to 0.40, transported to site, laid with fixed form/ slip form paver finisher (preferably with slip form paver finisher), spread, vibrated, compacted and finished in a continuous operation to the lines and grades as per drawing, texture finishing of surface, spraying two layers of curing compound, curing with water sprayed on hessian cloth covered over concrete surface, groove cutting grid 1m x 1m or as directed by Engineer Incharge to a depth of 1/3 to 1/4 of the Thickness and of width 3-5 mm as per design including cost of all material, side form work, labour and machineries etc. complete as per specifications.(Excluding Dowel Bars and Tie Bars) ( Including Polythene sheet 125 micron) And As Directed by Engineer Incharge

611.25

4571385

7478.75

... More
Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate ( natural sand/ VSI grade finely washed crushed sand) conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, , cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days,mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts,laid with a paver with electronic sensor /by suitable means as approved by Engineer-in charge , compacting with vibratory roller, finishing, curing and including preparation of sub-grade surface if required etc. complete. And As Directed by Engineer Incharge

407.5

1456955

3575.35

... More
Providing and fixing in position 25mm dia anti corrosive MS dowel bars of required Dia. 60 cms. Long and at 30.00 cm. C/C and wherever directed including handling. straightening, necessary cutting supported by chairs with proper alignment with half length covered by polyethene sheathing including cap etc. complete. And As Directed by Engineer Incharge

99

22992

232.25

... More
Providing and fixing in position anticorrosive TMT FE 500 tie bars of 12 mm dia. 70 cms. long and at 30.00 cm. C/C and wherever directed including handling, straightening necessary cutting, handling, straightening, supported by assembly of TMT FE 500, chairs with proper alignment etc. complete. And As Directed by Engineer Incharge

3001

190563

63.5

... More
Dismantling Stone Masonry as per Technical Specification MORD 2014 Clause 202. Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and all lead as per Technical Specification MORD 2014 Clause 202. Rubble Stone Masonry in Cement Mortar And As Directed by Engineer Incharge

31.2

18746

600.85

... More
Removing all types of Hume pipes and stacking with all lead including Earthwork and Dismantling of Masonry Works as per Technical Specification MORD 2014 Clause 202. Upto 600 mm dia Hume pipe And As Directed by Engineer Incharge

97.5

57339

588.1

... More
Earthwork in excavation for structures as per drawing and technical specifications Ministry Of Rural Development 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal all lead , dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary soil And As Directed by Engineer Incharge

998.39

669170

670.25

... More
Filling in foundation trenches as per drawing and technical specification Clause 305.3.9 Rubble soling with Rubble And As Directed by Engineer Incharge

171.87

349944

2036.1

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 Plane cement concreate grade M 10 with crushed sand VSI crusher Nominal mix 1:3:6 And As Directed by Engineer Incharge

155.52

982940

6320.35

... More
Providing concrete for plain/reinforced concrete in sub structure complete as per drawings and technical specifications Ministry Of Rural Development 2014 Clause 802, 803, 804, 805, 806, 807, 1202 & 1203, 1204 Plain cement concreate grade M 15 with crushed sand VSI crusher Nominal mix (1:2.5:5) And As Directed by Engineer Incharge

739.27

4854933

6567.2

... More
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. B. 1000 milimeter Non pressure 3 Class As per Technical Specification Ministry Of Rural Development 2014 Cluase No. 1100 And As Directed by Engineer Incharge

135

1019216

7549.75

... More
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. D. 600 milimeter Non pressure 3 Class As per Technical Specification Ministry Of Rural Development 2014 Cluase No. 1100 And As Directed by Engineer Incharge

90

347967

3866.3

... More
Providing and laying reinforced cement concrete pipe Non pressure2 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. D. 600 milimeter Non pressure 2 Class As per Technical Specification Ministry Of Rural Development 2014 Cluase No. 1100 And As Directed by Engineer Incharge

270

737910

2733

... More
Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1303 And As Directed by Engineer Incharge

54

117015

2166.95

... More
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets as per Clause 1106.

45

442422

9831.6

... More
Providing and laying of Boulder apron laid in wire crates with 4 mm dia GI wire confirming to IS-280 and IS 4826 IN 100 mm x 100 mm mesh (woven diagonally) including 10 percent extra for laps and joints laid with stone boulders weighing not less than 25 kg each as per drawing and technical specification clause 1301

175.31

587376

3350.5

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per Indian Road Congress:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Ministry Of Rural Development 2014 Clause 1703 5th Kilometre Stone (Precast) And As Directed by Engineer Incharge

1

5108

5108.1

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per Indian Road Congress:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Ministry Of Rural Development 2014 Clause 1703 Ordinary Kilometer Stone (Precast) And As Directed by Engineer Incharge

5

14869

2973.9

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per Indian Road Congress:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Ministry Of Rural Development 2014 Clause 1703 200 meter stone (precast) And As Directed by Engineer Incharge

23

19183

834.05

... More
Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per Indian Road Congress:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704. And As Directed by Engineer Incharge

224

188249

840.4

... More
Providing and fixing of typical PMGSY Retro Reflective information board as per as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing.Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottom duly rivetted with MS angles of 35 x 35 x 5 mm thick M.S angle shall be welded by two vertical M.S angle of 5 mm thick to 75 mm x 75 mm of 12 SWG square tubes / 75mm Dia Pipe posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 75mm, below ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2022. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 7 years for Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4 and as directed by Engineer-In-charge. . A warranty for 7 years for the Retro reflective sheeting for Class-B respectively, from original manufacturer shall be submitted by contractor. And As Directed by Engineer Incharge

2

37083

18541.95

... More
Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1. And As Directed by Engineer Incharge

2

36697

18348.7

... More
Providing and erecting direction and place identification of semi reflective sign boards as per IRC-67 made of 2 mm thick M.S. Sheet duly stove enameled paint white colour in front and grey colour on back with reflective border of 70 mm width and required message, letters, figures with reflective tape of engineering grade as per MORD specifications of required shade and colour. Supported and welded on two nos. 47 mm x 47 mm of 12 SWG square tube of 3050 mm height duly strengthened by 25 mm x 5 mm MS flat iron on edges on back firmly fixed to the ground by means of properly designed foundations with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701 .And As Directed by Engineer Incharge

6

24657

4109.5

... More
Providing and fixing Cautionary/Warning sign boards in Equilateral Triangle size of mm made out of mm aluminum sheet bonded with white retro reflective sheeting of Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3 Supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with grey stove enamel paint and supported on one no. of M. S. angle iron post of size 65 mm X 65 mm X 6 mm, 3.45 m long, duly painted with with flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in M25 grade concrete block of size 60cm X 60cm X 75cm including transportation etc; complete. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier. And As Directed by Engineer Incharge

52

199108

3829

... More
Providing and fixing of retro- reflectorised informatory sign board rectangular/Square in shape having area less than 0.9 One Square Meterr made out of mm aluminum sheet bonded with white retro reflective sheeting of Class ( Type IV High intensity micro- prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3, supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with two coats of grey stove enamel paint and supported on one no. mild steel angle iron post 75 mm x 75 mm x 6 mm, 3.5 mt long firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing The angle iron post shall be duly painted with one coat of epoxy primer and two coats of epoxy finish paints having alternate black and white bands of 25 cm width including GI fixures and transportation etc.complete.The nut bolts of board with angle iron post/supporting structure after fixing at site has to be electrically welded. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) sheeting shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier. 600 x 450 milimeter Rectangular And As Directed by Engineer Incharge

2.7

26100

9667

... More
Providing and fixing Mandatory/Regulatory sign boards in circular shape of mm dia made out of mm aluminum sheet bonded with white retro reflective sheeting of Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3 Supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with grey stove enamel paint and supported on one no. of M. S. angle iron post of size 65 mm X 65 mm X 6 mm, 3.45 m long, duly painted with with flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in M25 grade concrete block of size 60cm X 60cm X 75cm including transportation etc; complete. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier. 600mm circular And As Directed by Engineer Incharge

48

216768

4516

... More
Providing and Laying hot applied thermoplastic road marking strip on Bituminous Surface of specified shade/ colour of 2.5 mm thick including 1.5 Refractive index reflectorizing glass beads @ 250gm/sqm .Thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC 35:2015. Initial Dry reflectivity RL shall be 250 mcd/sqm/lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/sqm/ lux and Qd of 100 mcd/sqm/ lux measured at the end of 2 years by means of a Standard Reflectometer of Zehntner, Easylux, Delta make capable of measuring RL & QD both according to IRC 35:2015 clause 15.5. The finished surface to be level, uniform, and free from streaks and holes complete as per direction of Engineer-in-charge and in accordance with applicable specifications.(Refer MORTH Clause 803 for technical Specification and Performance for IRC 35:2015). And As Directed by Engineer Incharge

1120

753368

672.65

... More
Road Delineators: Supplying and installation of delineators (Roadway Indicators, Hazard markers, Object markers) 80 to 100 cm high above ground level, painted black and white in 15cm wide strips, fitted with 80x100mm rectangular or 75mm dia. Circular reflectorised panels at the top, buried or pressed into the ground and confirming to I.R.C. 79 and the drawings And As Directed by Engineer Incharge

42

34524

822

... More
Painting two coats including prime coat with epoxy paint of approved brand on concrete/steel surfaces after through cleaning of surface to give an even shade as per drawing and Technical Specification Clause 1701 And As Directed by Engineer Incharge

5.4

893

165.5

... More
White washing two coats on parapet walls and white washing and geru lime painting to tree trunks including preparation of surface by cleaning scraping etc. complete And As Directed by Engineer Incharge

33

858

26

... More
A,W : Metal Beam Crash Barrier (Providing and erecting a "W "metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip cess, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810) And As Directed by Engineer Incharge,

72

353664

4912



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.