Power System Operation Corporation Limited Tender
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Power System Operation Corporation Limited - POSOCO Tender
Electrical and Electronics
Eprocure
Opening Date21 Aug 2019
Closing Date23 Sep 2019
Tender Amount₹ 56,80,739
Costs
EMD
₹ 1,14,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_POSOC_496094_1Tender No
WRLDC/CON/WC-1371/19Tender Authority
Power System Operation Corporation Limited ViewPurchaser Address
-Website
http://https://posoco.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Tender document for detailed scope of work and other terms and conditions of the contract
BOQ Items
Supply of M.S. 'C' Class Chilled water piping for 100 mm size:
24
-
-
Supply of 50 mm thick with AL cladding on Polyurethane Foam pipe Sections for 100 mm Size
24
-
-
Supply of valves as below PN 16:
-
-
-
Butterfly Valve-100 mm Dia
10
-
-
Maunal Balancing valve- 100 mm
Dia
2
-
-
Y-strainer-100 mm Dia
3
-
-
Single Arch Rubber Bellow 100mm
10
-
-
NRV- 100 mm Dia
3
-
-
Drain Valve
3
-
-
PG
10
-
-
TG
10
-
-
Air vent
3
-
-
Supply of 3.5C x 120 Sq. mm. AL cable (chiller) double compressor glands-2 nos, CU lugs- 8 nos and 3C x 6 Sq. mm. Al Cable (pump) gland-3 nos, CU lugs-9 nos.
1
-
-
Supply of 25 x 3 mm GI. Flat strip for chillers earthing- approx 10 Mtr
75
-
-
Part-B; Services Portion:
-
-
-
Installation, integation, testing and commissioning of 60 TR Air cooled, Refrigerant - R-410A/ R-407C new technology scroll type energy efficient chiller unit with all accessories, including civil foundation(if requires) and other civil/mechanical work as required and as per direction of engineer-in-charge
2
-
-
Installation, integation, testing and commissioning of end suction back pullout type primary chilled water pumps with capacity- 180 USGPM, Head- 25 Meter with all accessories, including civil foundation (if requires) and other civil/mechanical work as required and as per direction of engineer-in-charge
3
-
-
Installation, fabrication, integation, testing and commissioning of M.S. 'C' Class Chilled water piping for 100 mm size as per direction of engineer-in-charge:
24
-
-
Installation, fabrication, integation, testing and commissioning of 50 mm thick with AL cladding on Polyurethane foam pipe Sections for 100 mm size as per direction of engineer-in-charge:
24
-
-
Installation, integation, testing and commissioning of valves as below as per direction of engineer-in-charge:
-
-
-
Butterfly Valve-100 mm Dia
10
-
-
Maunal Balancing valve- 100 mm Dia
2
-
-
Y-strainer-100 mm Dia
3
-
-
Single Arch Rubber Bellow 100mm
10
-
-
NRV- 100 mm Dia
3
-
-
Drain Valve
3
-
-
PG
10
-
-
TG
10
-
-
Air vent
3
-
-
Electrical works: Cable termination and commissioning of 3.5C x 120 Sq. mm. AL cable (chiller) double compressor glands-2 nos, CU lugs- 8 nos and 3C x 6 Sq. mm. Al Cable (pump) gland-3 nos, CU lugs-9 nos and as per direction of engineer-in-charge.
1
-
-
Electrical works: Laying and fixing of 25 x 3 mm GI. Flat strip for chillers earthing - approx 10 Mtr
75
-
-
Dismantling of existing 60TR reciprocating chiller units including 3 nos water pump and shifting the same to scrap yard as required at site.
2
-
-
Part-C : Comprehensive AMC for 2x60 TR Chiller unit:
-
-
-
1st year under Defect liability period (Warranty period)
1
-
-
1st year after Defect liability period (Warranty period)
1
-
-
2nd year after Defect liability period (Warranty period)
1
-
-
3rd year after Defect liability period (Warranty period)
1
-
-
4th year after Defect liability period (Warranty period)
1
-
-
5th year after Defect liability period (Warranty period)
1
-
-
Buyback Items
-
-
-
Buy back of existing 60TR reciprocating type chiller units including 3 nos chiller water pump.
2
-
-
Evaluation Notes How It Works ?