National Environmental Engineering Research Institute Tender
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
National Environmental Engineering Research Institute - NEERI Tender
Eprocure
Opening Date31 Jul 2021
Closing Date14 Aug 2021
Tender Amount₹ 32,90,428
Costs
EMD
Refer DocumentsDocument Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_CSIR_83697_1Bid Award Id
ViewTender No
50(04)/2021-22/WTender Authority
National Environmental Engineering Research Institute ViewPurchaser Address
-Website
http://csir.res.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
2.5 sq.mm.wire
720
-
-
4.0 sq.mm.wire
450
-
-
6.0 sq.mm.wire
270
-
-
Flexible CU cable 1.5 sq.mm. - 3 core
180
-
-
Flexible CU cable 2.5 sq.mm. - 3 core
90
-
-
Supplying of following sizes of PVC conduit/PVC casing caping.
-
-
-
20 mm
100
-
-
25 mm
25
-
-
32 mm
10
-
-
Supply of follwing piano flush type switch/socket. Item must be same as existing one, fitted at the site to maintain the uniformity
-
-
-
5/6 amps switch
200
-
-
2 way 5/6 amps switch
30
-
-
15/16 amps switch
50
-
-
3 pin 5/6 amps socket
100
-
-
6 pin 15/16 amps socket
25
-
-
Bell Push
40
-
-
Supply of fixing following modular switch/socket. Item must be same as existing one, fitted at the site to maintain the uniformity
-
-
-
5/6 amps switch
30
-
-
2 way 5/6 amps switch
10
-
-
15/16 amps switch
10
-
-
3 pin 5/6 amps socket
20
-
-
6 pin 15/16 amps socket
15
-
-
Bell Push
5
-
-
Supply of Sunmica board of size 4"× 4" for switch
20
-
-
Supply of Sunmica board of size 7"× 4" for switch
25
-
-
Supply of Sunmica board of size 8"× 10" for switch
25
-
-
Supply of 3 pin,5 amps ceiling rose on the juction box/wooden block
10
-
-
Supply of brass batten / pendent holder / angle holder
250
-
-
Supply of call bell (Ding dong type) / buzzer suitable for single phase ,230 V
30
-
-
Supply of Stepped type Modular ceiling fan regulator - Double Module. Item must be same as existing one, fitted at the site to maintain the uniformity
75
-
-
Supply of Modular Elecronic type ceiling fan regulator - Single module. Item must be same as existing one, fitted at the site to maintain the uniformity
20
-
-
Supply of 2.5 MFD capacitor for all types of fans. Item must be same as existing one, fitted at the site to maintain the uniformity
150
-
-
Supply of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
40
-
-
Supplying metal exhaust fan A. C. 230 V. of 300 mm sweep. Air Delivery 19 CMM, 55 Watts, 900 RPM, Dynamically balanced blades for vibration free rotation, alluminium die-cast body to ensures long life & all accessories etc. (With two years guarantee) Item must be same as existing one, fitted at the site to maintain the uniformity
5
-
-
Supply of 5 amps to 32 amps rating 240 V miniature circuit breaker of single pole. Item must be same as existing one, fitted at the site to maintain the uniformity
50
-
-
Supply of 5 amps to 32 amps rating 240 V Miniature Circuit Breaker (MCB) of single pole & Neutral. Item must be same as existing one, fitted at the site to maintain the uniformity
5
-
-
Supply of 5 amps to 32 amps rating 440 V Miniature Circuit Breaker (MCB) of Triple pole. Item must be same as existing one, fitted at the site to maintain the uniformity
5
-
-
Supply of 40 amps rating Double Pole ( single phase & Neutral) 240 V residual current circuit breaker RCCB having a sensitivity current up to 30 mA. Item must be same as existing one, fitted at the site to maintain the uniformity
20
-
-
Supply of crimping type Aluminum lugs confirming to IS suitable for cable up to 35 sq.mm Evently crimped with high pressure tools and connected to switch gear terminal with brass / cadmium plated nut bolts in an approved manner.
16
-
-
Supply of crimping type Aluminum lugs confirming to IS suitable for cable up to 95 sq.mm Evently crimped with high pressure tools and connected to switch gear terminal with brass / cadmium plated nut bolts in an approved manner.
16
-
-
Supply of crimping type Aluminum lugs confirming to IS suitable for cable up to 120 sq.mm Evently crimped with high pressure tools and connected to switch gear terminal with brass / cadmium plated nut bolts in an approved manner.
16
-
-
Supply of crimping type Aluminum lugs confirming to IS suitable for cable up to 240 sq.mm Evently crimped with high pressure tools and connected to switch gear terminal with brass / cadmium plated nut bolts in an approved manner.
16
-
-
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials upto 3½ X 50 sq. mm size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
2
-
-
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials upto 3½ X 150 sq. mm size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
1
-
-
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials upto 3½ X 240 sq. mm size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
1
-
-
Supplying 36 W LED Tube rods with a rating of 240 V.
20
-
-
Supplying 36 W LED industrial batten for surface mounting type (white vitreous enamelled / powder coated) made from CRCA sheet with one no. of LED T8 Tube lamp having not less than 1800 lumens complete with 230 V, driver (SMPS) A.C supply with necessary materials and guarantee of five years.
10
-
-
Supplying LED Bulb of 7 W, 230 V A.C., Cool white (white vitreous enamelled / powder coated) having not less than 630 lumens complete with necessary materials and guarantee of five years.
25
-
-
Supplying 12 W, LED indoor luminaire for 8" inch size of round/square shape surface mounting type fitting having PDC alluminium housing and PMMA diffuser complete for 240 V, A.C supply with necessary materials as required. Item must be same as existing one, fitted at the site to maintain the uniformity.
10
-
-
Supplying 20 W LED industrial batten for surface mounting type (white vitreous enamelled/ powder coated) Made from CRCA sheet with one number of LED T8 Tube lamb having not less than 1800 lumens complete with 230 V driver.
10
-
-
Supplying 20 W LED Tube rods with a rating of 240 V.
30
-
-
Supply of single phase Electrical energy meter 10 -40 Amp 10-40 Amps with LCD display, class 1 accuracy.
5
-
-
Earthing with G.I earth plate 600 × 600 × 6 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal or coke and salt complete as reqiured
1
-
-
Providing and laying earth connection from earth electrode with 6 SWG dia G.I wire in 15 mm dia. G.I pipe from earth electrode including connection with G.I thimble excavation and re-filling as required.
15
-
-
Providing and fixing 6 SWG dia GI wire on surface or in recess for loop earthing as required.
30
-
-
Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and re-filling the trench etc.as reqiured.
-
-
-
Upto 35 sq.mm
50
-
-
Above 35 sq. mm & upto 95 sq. mm
30
-
-
Above 95 sq. mm & upto 185 sq. mm
30
-
-
Above 185 sq. mm & upto 400 sq. mm
30
-
-
Laying & fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
-
-
-
Upto 35 sq.mm
50
-
-
Above 35 sq. mm & upto 95 sq. mm
30
-
-
Above 95 sq. mm & upto 185 sq. mm
30
-
-
Above 185 sq. mm & upto 400 sq. mm
30
-
-
Excavation for foundation in soft soil including dressing of sides & ramming of bottoms, lift upto 1.5 m including getting out the excavated soil & disposal of surplus excavated soil as directed , within a lead of 50 meters.
5
-
-
Filling available excavated earth (excluding rock) in trenches, side of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering , lead up to 50 meters.
5
-
-
Supply of 200A, 16 KA, Four Pole MCCB rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in exixting cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
1
-
-
Supply of 150 A, 16 KA, Four Pole MCCB rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in exixting cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
2
-
-
Supply of 125 A, 16 KA, Four Pole MCCB rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in exixting cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
2
-
-
Installation of exhaust fan Upto 450 mm sweep in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
5
-
-
Supplying of 8 way , Double door, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
5
-
-
Supplying armoured cable 4 x 10 sq mm: Armoured cable of XLPE insulated (cross linked polythelene) PVC sheathed, armoured with galvanised round / strip steel, 1100 V. grade conforming to I.S. 1554 (part-1) & IS :7098 (part-1), 4 core 10 Sq. mm. stranded Aluminium conductor.
150
-
-
Comprehensive maintenance of street lights at CSIR-NEERI, Nagpur campus having more than 250 street light poles (More than 200LED Fittings) ( 125 poles in Institute & 125 in east west colonies) on pole of length upto 13 meters with fittings of 150 W & 250 W HPSV Lamp, 4 X 24 T5 lamps, 24 watt ballast. 35 W to 100 W LED Lights, fittings. Contractor shall be responsible of working operation of street lights thoroughout 365 days. No material tools & plants including ladder will be provided to the contractor. Contractor will have to provide each & every spare part of the street light fitting such as Lamp, Ballast, condensor, Igniter, starters, whole fittings & other misc materials.
12
-
-
Supplying,installation,testing and commissioning of Astronomical time switch of 3 output (1output per phase) and suitable for three phase supply configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required
2
-
-
Supply of Stepped type Flush Type ceiling fan regulator - Double Module. Item must be same as existing one, fitted at the site to maintain the uniformity
50
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements