National Chemical Laboratory Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

National Chemical Laboratory - NCL Tender

Works
Civil And Construction
Civil Works Others
Eprocure
Opening Date29 Mar 2023
Closing Date10 Apr 2023
Tender Amount₹ 6,59,814 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Wiring for circuit wiring with 2x4sqmm + 1 x 4 sqmm as earth PVC insu.copper cond. FRLS wires Polycab/Finolex/RPG make, 1100V grade in PVC conduit pipe Asina/Diamond make including accessories & connections at both ends. (circuit mains for lighting)

70

-

-

... More
Wiring for circuit wiring with 4x4sqmm + 2 x 4 sqmm as earth PVC insu.copper cond. FRLS wires Polycab/Finolex/RPG make, 1100V grade in PVC conduit pipe Asina/Diamond make including accessories & connections at both ends. (circuit mains for lighting)

40

-

-

... More
Supplying & fixing 6Amp 2 in 1 modular socket & 10A switch MK Blenz PLUS/ Legrand Myrius Nex Gen make on wall or on lighting control board complete with surface box & Modular plate.

6

-

-

... More
Supplying, fixing & connecting on wall switch board with 6 Amp, 2 in 1 modular socket--3Nos & S.P. modular switch 10A--3nos, 16/6AAmp, 2 in 1 modular socket--1No, & S.P. modular switch 20A---1no. Legrand Myrius Next Gen/ MK Blenz PLUS make. Complete with modular front plate & Metal surface box of appropriate size for mounting of switch board. Switch board should be fixed on wall with the help of screws & rawal plugs.

28

-

-

... More
Supplying & laying on wall/cable tray PVC armoured cable, 3.5 core x 35sqmm, Polycab /Gloster /Asian Make, Aluminium conductor, 1.1Kv grade at NCL site. (Before supplying cable, actual measurement at site should be taken in consultation with site engineer.) The cable should be fixed to the tray with M.S. screws. (For catalysis Lab)

30

-

-

... More
Termination of 3.5 core, 35 Sqmm Akuminium conductor armoured cable with suitable size of Aluminium crimping type lugs into the existing power DB and other end into load. The siemens type cable gland should be used for termination of cable

2

-

-

... More
Supplying & laying on wall/ cable tray PVC armoured cable, 2 core x 4sqmm, Polycab /Gloster /Asian Make, copper conductor, 1.1Kv grade at NCL site. (Before supplying cable, actual measurement at site should be taken in consultation with site engineer.) The cable should be fixed to the tray with M.S. screws.(Working tables)

90

-

-

... More
Supplying & laying on wall/cable tray PVC armoured cable, 4 core x 4 sqmm, Polycab /Gloster /Asian Make, copper conductor, 1.1Kv grade at NCL site. (Before supplying cable, actual measurement at site should be taken in consultation with site engineer.) The cable should be fixed to the tray with M.S. screws. (For Fume hoods)

20

-

-

... More
Termination of 2 core, 4 Sqmm Copper conductor armoured cable with suitable size of Copper crimping type lugs into the existing power DB and other end into load. The siemens type cable gland should be used for termination of cable

20

-

-

... More
Termination of 4 core, 4 Sqmm Copper conductor armoured cable with suitable size of Copper crimping type lugs into the existing power DB and other end into load. The siemens type cable gland should be used for termination of cable

6

-

-

... More
Supplying & fixing Exhaust fan GEC/Orient make, Heavy duty metal body, 300"sweep in window complete with frame, Plywood, brackets & louvers.

4

-

-

... More
Supplying & fixing in metal enclosure DPMCB 32 Amp, MDS Lexic/ Siemens/C&S make on wall complete with connections & testing. (For swt & cwt)

10

-

-

... More
Supplying & fixing in metal enclosure Four pole MCB 32 Amp, MDS Lexic/ Siemens/ C&S make on wall complete with connections & testing. (For Fume Hoods )

3

-

-

... More
Supplying, fixing & connecting on ceiling prewired LED light fitting recessed Type Philips make cat No. RC380B LED 36S 6500 G5L3W12PSU OD 28W/ Wipro Make Cat No.Aura Plus CRC013 36 Watts, / Havells' Make Cat No.Pluto, NEO HE LED Panel 857S 4X1 Watts, 4' or Equivalent of Philips make complete with hanging support from ceiling & Driver.The LED Light fiting should have minumum 3 years replacement warranty. (For flase ceiling area concealed 4' fitting)

10

-

-

... More
Supplying, fixing & connecting on ceiling prewired LED light fitting Surface 4' x 1' Type 30-36Watts Philips make cat No.SM270C LED 30S 6500K PSU WH 32 watts/ Wipro Make Cat No.AURA PLUS CRCO13S038HP57G1, 31Watts / Havells' Make Cat No.PLUTONEO4X1PLR36WLED840S, 5700k, 4'x1 with suspension kit 1.5 mtr, complete with Driver.The fitting should be hung from the ceiling by using suspension kit fixed to the ceiling.The LED Light fiting should have minumum 3 years replacement warranty. (For Laboratories surface fittings)

30

-

-

... More
Supplying, fixing & connecting on ceiling prewired LED light fitting Recess muonting type Philips make cat No.RC380B LED36S-6500 G6 L60W60 PSU OD 30watts/ Wipro Make Cat No.Elate CRCO10 36-42 Watts, / Havells' Make Cat No:Recess VENUS NEO HE 36-42 Watts, 2'x2'' complete complete with hanging support from ceiling & Driver. Proper equipmenst will be required to replace fittings. The LED Light fiting should have minumum 3 years replacement warranty (For Labs with 2'x2' Armstrong false ceiling area)

30

-

-

... More
Supplying, fixing & connecting on ceiling/wall with prewired LED tube light fitting with metal body Philips make cat No.BN021C LED40S-6500 PSU CW GR(4Ft)/ Havells make cat no. Lumiline Plus 24W/ Wipro make, Philips make 22W, 4' complete with accessories.The LED Light fiting should have minumum 3 years replacement warranty (Toilets,Small offices etc)

20

-

-

... More
Supplying & fixing completely assembled MDS make main PowerVTPN distribution board, 3 phase 8way with 4 pole Lexic make MCB 63A cat No608702--1No as incomer & TPMCB 25-32A- 3Nos. & 15Nos of 6-20A SPMCBs Lexic make as O\G. The distribution box should be fixed on wall with Anchor fastners. Enclosure should be double door type with IP 43 potection Legrand make,Cat No.507727 with cable end boxes. Rate is inclusive of Lexic make metal enclosure,MCBs & cable end boxes. (Main DBs at Catalysis & Polyolefene Labs )

3

-

-

... More
Dismantling the existing Tube light fittings from ceiling/false ceiling carefully without damaging the fittings.The dismantled material should be returned to the NCL stores at no extra cost.

20

-

-

... More
Fabricating,painting,supplying,fixing on wall with anchor fastners box type cable tray of Size 200 mm width x 75 mm deep made from 16 SWG CRCA sheet. The cable tray should have 16 SWG CRCA sheet cover throughout its length with proper screwing. The tray should be powder coated with Siemens Grey colour.The tray should be provided with suitable cable fixing arrangement inside the tray. (Before fabrication of cable tray layout should be decided & actual measurement at site should be taken in consultation with site engineer.){For main cables to working tables}

20

-

-

... More
Fabricating,painting,supplying,fixing on wall with anchor fastners box type cable tray of Size 75 mm width x 50 mm deep made from16 SWG CRCA sheet. The cable tray should have 16 SWG CRCA sheet cover throughout its length with proper screwing. The tray should be powder coated with Siemens Grey colour.The tray should be provided with suitable cable fixing arrangement inside the tray. (Before fabrication of cable tray layout should be decided & actual measurement at site should be taken in consultation with site engineer.) {For power cables}

20

-

-

... More
Supply Istallation, Testing & Commissioning Fire Alarm Panels 4 Zone, microprocesser based, conventional type, wall mounting with a provision of power supply unit of 240 V AC 50 Hz. & Built in 24 Volts DC Battery. Ravel / System sensor Honeywell/Ceasfire make

2

-

-

... More
Supply, Erection, Testing and Commissioning of conventional type optical smoke detector, latest modles of Ravel/System sensor Honeywell/Ceasfire make.

80

-

-

... More
Supplying installation Testing & commissioning of Hooter cum strobe with ABS enclosure for each zone to activate during fire condition/signals by detectors, working on 24V DCwith flasher to get activated during the fire 80 db output. Ravel/System sensor Honeywell/Ceasfire make

4

-

-

... More
Supply, erection Testing & Comissioning of Manual call point(Pill Box type) with break glass or resettable inmetal encloure complete. Ravel/System sensor Honeywell/Ceasfire make

4

-

-

... More
Supplying & erecting on wall/ceiling PVC insulated FRLS Red Coloured armored cable 2 core x1.5 sqmm Copper conductor Polycab/Finolex make.

450

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.