Munitions India Limited Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Munitions India Limited Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date14 Sep 2024
Closing Date5 Oct 2024
Tender Amount₹ 12,51,913 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
S& F galvanised steel wire 3.14 or 4 mm dia.  

2

-

-

... More
M&L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint

2

-

-

... More
S & F galvanised stay wire strand size 7/4mm.  

0.4

-

-

... More
S& F stay assembly complete with 20 mm dia. Stay rod and other assessories as shown in electrical plate No. 1. (Excavation and concrete, loop insulator and stay clamp to be mesaured separately)  

2

-

-

... More
Rough excavation in hard dense soil in trenches not exceeding 1.5 mtr deep & 1.5 mtr wide and getting out  

50

-

-

... More
Rough excavation in Mud in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth and getting out.

50

-

-

... More
Rough excavation in hard rock in trenches not exceeding 1.5 mtr deep and 1.5 mtr wide and getting out  

15

-

-

... More
Back filling of excavated soil spreading, levelling, watering & well ramming in layers.  

115

-

-

... More
M & L fine sand filling in the trench for cushioning of cable /Substation trench filling. 

20

-

-

... More
Demolition and dismantling of Cement concrete (unreinforced) in ground floors and pavings not exc 15 cm thickness (below or above ground level).  

1

-

-

... More
M & L for remaking of concrete by PCC of 1:2:4 of type B-2 using 40 mm aggregate.  

30

-

-

... More
M&L for Galvanised steel tube medium grade 100 mm dia.

30

-

-

... More
M&L for UN-REINFORCED PRECAST CONCRETE CABLE COVER , CLASS HV, TYPE 1, Flat, size 300mmX180mm X40 mm in the cable trench .  

1500

-

-

... More
S&F Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed by EIC.

200

-

-

... More
Labour only for Repairing/Fixing/Restringing/removing of ACSR / Copper / GI conductor of any size for repairing of HT OH lines per span per conductor.  

80

-

-

... More
Labour only for Rejointing of broken/ defective jumper wire/ cable lead/lug on HT pole by re-binding/ reluging.  

100

-

-

... More
Labour only for 11 KV HT OCB/VCB maintenance work like Cleaning, IR Testind, BDV Test of Oil, Contacts cleaning, Bushing, Overhauling, varnishing/ epoxy painting etc and as directed by EIC.

8

-

-

... More
Labour only for maintenance of HT Panels (Excluding OCB/VCB) including busbar and cable chamber equipments, Insulators, Terminations, CT, PT, shutter mechanism, IR value testing and improvement, closing/tripping operation etc and as directed by EIC

8

-

-

... More
Labour only for Transformer Oil top-up, Breather, IR Test, TF Oil BDV test, Earth Resistance test, Buchholtz Relay Test, bushings, valves etc. For transformer capacity from 100 KVA to 10 MVA and as directed by EIC ( Material will be provided by OFBa)

10

-

-

... More
Labour only for Shifting of Indoor/Outdoor type Transformer, Panel, VCB/OCB, AB Swiches by dismanteling in good condition for reuse as directed by EIC ( Store to be hand over to OFBa)

8

-

-

... More
Labour only for Triming of Tree branches on overhead line, Adjascent to DP/4-Pole Structure during Patrolling of HT Line etc as directed by EIC

8

-

-

... More
Labour only for Dismantling of faulty Disc insulator, taking down ACSR conductor with turfer/tension arrangement, removing of jumpers or fixing of new Disc Insulator and tension hardware, restringing of ACSR conductor, re-jumpering, completeness of work and restoring power supply to healthy condition and as directed by EIC ( Materials will be provided by OFBa)

6

-

-

... More
Labour only fo Dismantling of faulty Pin insulator, taking down ACSR conductor or fixing of new insulator (5 KN/10 KN), its hardware, pin, binding, jumpering etc and as directed by EIC ( Materials will be provided by OFBa)

6

-

-

... More
M & L for epoxy insulation paint( Make STANVAC ; Product Code Z906 Provar Anti-tracking, Aerosol Spray, Can of 500 ml.) or it's equivalent and painting of insulated bus-bars, HT insulator, CT, PT, Cast Resin equipment damaged by partial discharge/Tracking of complete feeder and as direcetd by EIC ( Materials will be provided by Contractor)

4

-

-

... More
Labour only for 11 KV Air Break Switch overhauling and maintenance as directed by EIC ( Materials will be provided by OFBa)

25

-

-

... More
Labour only for dejungling/grass cutting under and adjascent to HT overhead line, Pole structures, substation surroundings etc.

3000

-

-

... More
M&L cable route marker fixing on existing under ground cabling with PCC base (300*300*200mm) including earth removing and refilling.( Route marker with MS angle and hardwares will be provided by O.F Bhandara)

20

-

-

... More
Labour only for HT & LT under ground cable fault locating using cable fault locator instrument as directed by EIC ( Cable fault locator shall be arranged by Contrcator).

2

-

-

... More
Labour only for Shifting of Cable drum , Laying & Connection of HT cable , Size 70 sq.mm to 240 Sq.mm only.(Cable will be supplied by O.F.Bhandara)

200

-

-

... More
M&L for ready mix special grade asphalt (self grade) premixed with special aggregate and chemical plus pressure sensitive polymers for pavement surface /poth holes repair by cold application in wet or dry weather preferably insta patch.

400

-

-

... More
Labour only for disconnecting/reconnection of HT cable in panel/ AB Switches/ Transformer for testing/ repairing/ maintenance of Cable per cable per end of any size and any type.

15

-

-

... More
M&L for replacement of faulty DO fuse on Pole mounted Transformers of any rating as directed by EIC.

20

-

-

... More
Labour only for removal/filling of sand in cable trenches during removal/maintenance of Cable/Panel etc.

10

-

-

... More
Labour only for Patrolling/Inspection of HT Line/Cabling during searching of exact fault location.

8

-

-

... More
M&L for Double wall Corrugated (DWC) Pipe of HDPE, Industrial grade heavy duty Type INSIDE dia should be greater than 107mm minimum suitable to fit to 100mm dia GI Pipes. Corrugation shall be on outer wall but inner wall shall be plain.

18

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.